Escolar Documentos
Profissional Documentos
Cultura Documentos
ACKNOWLEDGEMENT
First of all, I wish to thank and acknowledge my sincere gratitude towards Dr. Vinod Jain,
Managing Director, Vintech Consultants, Greater Kailash I, New Delhi for permitting me to
get Summer Training at this organization.
I wish to express my deep sense of gratitude to my supervisor Ms. Shruti Sharma, Team
Leader and Sr. Structural Engineer, Vintech Consultants for her invaluable guidance,
encouragement and support throughout every phase of my training. This endeavor would not
have been possible without her untiring efforts and generous help.
Further, I wish to express my appreciation to Mr. Anuj Chauhan, Mr. Gaurav Mediratta, Mr.
Poorak Varma, Mr. Mohd. Iftikhar for their encouragement and providing the necessary guidance
and information of the subject.
I am also deeply thankful to my team member Hemant Jain, Pragya Gupta, Garv Suri, Tanveer
Singh, Trainee Engineer, Vintech Consultants for their kind support, help and cooperation
throughout.
It is my privilege to express my immense sense of gratitude to my parents and my brothers
for their continuous motivation, understanding and co-operation.
Sukrit Malhotra
INTRODUCTION
Structural engineers are responsible for engineering design and analysis. Entry-level
structural engineers may design the individual structural elements of a structure, for example
the beams, columns, and floors of a building. More experienced engineers would be
responsible for the structural design and integrity of an entire system, such as a building,
bridge or a complex.
The role of a structural engineer today involves a significant understanding of both static and
dynamic loading, and the structures that are available to resist them. The complexity of
modern structures often requires a great deal of creativity from the engineer in order to ensure
the structures support and resist the loads they are subjected to.
and
functionality.
SERVICES OFFERED
Vintech approach every consulting project being highly responsive to client needs, extremely
flexible in our outlook and by unleashing the full force of our creativity all while staying
within the practical bounds of the project.
From investigation, to planning, design, budgeting and construction, clients can rely on
Vintech to provide them with the brilliant, but functional outcomes to make project a success.
For the purpose of design Vintech is compatible with STAAD Pro, ETABS & SAFE
softwares whereas drawings are drafted in AutoCAD. With our past experience and research,
number of worksheets had been prepared to expedite analysis and design.
In the beginning of the every project, a structural scheme is formulated for the project. The
scheme is discussed extensively (in house) if required consultation is taken from
academicians. The proposed structural system is then forwarded to architects/clients for
approval. Three-dimensional structural system is generated in design software. Efforts are
applied to simulate the structure in the way, it is happening in actual buildings. The results
from analysis are thoroughly investigated and studied; special consideration is given to the
codal requirements.
The Structural Design and Details issued by VINTECH are entirely in the limitations of
Indian Standards. Infact at some instances where Indian Standards are silent we consult to
International Standards. VINTECHs coup de matre is completing more than 500 successful
structures which are the result of well-coordinated team (that includes the client) with
everyone doing their part and clearly understanding the requirements of each team member.
Our commitment to fresh thinking has led to a number of significant engineering
breakthroughs.
Week 2
The training report comprises of seven chapters relating to the work done
in the training period.
Week 1 deals with the company history, work culture, hierarchy and vision for future. It
includes the glimpse of the work which has been detailed in the later chapters of this report.
Additionally, it covers the services offered by the organization to the client and the softwares
mainly used for contriving and development.
Week 2 incorporates the basic design software used for design in the organization that is
ETABS. The ETABS is a product of Computer and Structural Inc. or CSI and has been in
employment from more than 6-7 years in the organization. ETABS can design structure
considering both static and dynamic loading (Earthquake loading) as per the codal provisions
of IS 456:2000 also incorporating the IS: 13920 1993 for ductile detailing.
Week 3 comprises of the modeling of an example structure with 7 story height. It includes
the drawing of the beam members, defining their properties & dimensions and adding slabs,
shear walls and columns to the provide height to the structure. It incorporates the design of
beams, columns and shear walls. Other useful commands and menus are also included like
Display Menu, View Menu and Zoom, Pan, Lock/Unlock structure sans which the modeling
couldnt have been possible.
Week 4 comprises of the description of the structure from the project disposed to me. The
structure is a high rise G+32 floored tower from residential blocks coming up in NOIDA by
Jay Pee associates named GREEN ISLES. The loading adopted, cost comparison between
framed and flat slab system and description of design of the building are described. In
addition to it, the various codes followed, cover provided, reinforcement detailing, foundation
and basement details, material specifications are also explained.
ETABS
OVERVIEW
ETABS is an engineering software product that caters to multi-story building analysis and
design. Modeling tools and templates, code-based load prescriptions, analysis methods and
solution techniques, all coordinate with the grid-like geometry unique to this class of
structure. Basic or advanced systems under static or dynamic conditions may be evaluated
using ETABS. For a sophisticated assessment of seismic performance, modal and directintegration time-history analyses may couple with P-Delta and Large Displacement effects.
Nonlinear links and concentrated PMM or fiber hinges may capture material nonlinearity
under monotonic or hysteretic behavior. Intuitive and integrated features make applications of
any complexity practical to implement. Interoperability with a series of design and
documentation platforms makes ETABS a coordinated and productive tool for designs which
range from simple 2D frames to elaborate modern high-rises.
ETABS is a powerful program that can greatly enhance an engineer's analysis and design
capabilities for structures. Part of that power lies in an array of options and features. The
other part lies in how simple it is to use.
The basic approach for using the program is very straightforward. The user establishes grid
lines, places structural objects relative to the grid lines using points, lines and areas, and
assigns loads and structural properties to those structural objects (for example, a line object
can be as-signed section properties; a point object can be assigned spring proper-ties; an area
object can be assigned slab or deck properties). Analysis and design are then performed based
on the structural objects and their assignments. Results are generated in graphical or tabular
form that can be printed to a printer or to a file for use in other programs.
In using the program, you manage the File, Edit the model, change the View, Define
properties or load and analysis cases, Draw something new in the model, Select that
something, Assign properties or loads, Analyze the model, Display analysis results for
checking, Design the structure, apply various Options to achieve the desired outcome with
optimum effort, and seek Help when you need it. Those actions are the basis for the program
menu structure. Thus, familiarity with the menu commands and their function is key to
expanding your ability to use ETABS.
Familiarity with the menu commands will enable the user to create models for complex
Composite Floor Framing Systems with Openings and Overhangs, Steel Joist Systems,
Moment Resisting Frames, Complex Shear Wall Systems, Rigid and Flexible Floors, Sloped
Roofs, Ramps and Parking Structures, Mezzanine Floors, Trussed Systems, Multiple Tower
Buildings and Stepped Diaphragm Systems, and many more.
STRUCTURAL MODELLING
Fundamental to ETABS modeling is the generalization that multi-story buildings typically
consist of identical or similar floor plans that repeat in the vertical direction. Modeling
features that streamline analytical-model generation, and simulate advanced seismic systems,
are listed as follows:
WEEK 3
MODELLING
DEFINING
Define
Member Cross -section
To define the cross section of a
beam or a column.
Define
Wall/Slab Sections
Define > Wall/Slab/Deck Sections >Add Rectangular
The walls and the slab to be used as required should be defined. The thickness of the
wall and slab and the material to be used (grade of concrete) is to be filled.
DRAWING
Draw points by using Draw Point Objects command. This command enables user to
plot points for the placing of line objects like beams and columns.
Point
objects of
two types:
Joint objects are automatically created at the corners or ends of all other types of
objects, and they can be explicitly added anywhere in the model.
Grounded (one joint) link objects are used to model special support behavior, such
as isolators, dampers, gaps, multi-linear springs and more.
This command requires to set an origin point with co-ordinates (0,0,0). Other points are
plotted with respect to origin or any other plotted point. This eventually results in a plan
having the basic visual description of base or a story level. The following shows the point
Draw beams and columns using Draw Line Objects command. This command helps the
user to plot beams and columns between the points plotted.
Frame objects are used to model beams, columns, braces and trusses.
Connecting (two-joint) link objects are used to model special member behavior, such
as isolators, dampers, gaps, multi-linear springs, and more. Unlike frame objects,
connecting link objects can have zero length.
This commands require the selection of minimum two point objects between which the beam
or column is to be placed. This results in a story with all required line (beam or column)
objects. The following shows the beams for a particular story:
In
the
same way, columns for a story are provided. While placing beams, sometimes Snap to
Perpendicular Projections is useful for removing projections which are not required.
Draw Columns
To
draw
column in
the
structure
go to Draw
Menu
>
Draw Line
Objects >
Select the section of the column defined earlier and place the column as required or decided
by the structural engineer in accordance with the approval of the architect. The architects
perceive columns as an impediment to the aesthetic beauty of a room or a hall. They require
the column to be located in the wasteland (areas that are not of architectural importance in a
buildings). A column inside a hall generally deters the appearance of the hall, especially if
the building is supposed to be a banquet hall or museum with impeccable art or a drawing
room of a house which is the first place for a guest to see. Also, the column with large cross
sections if placed inside a room will acquire much of the necessary living space which also is
undesirable with such surging costs of properties in todays scenario.
So, the job of the structural engineer becomes all the more difficult with economic, aesthetic,
and safety constraints as far as a building is concerned. Placing of columns really requires
patience, experience and expertise.
Select the appropriate property of the wall that will define the thickness, type of material used
in the wall as shown in fig.
The lower fig shows the shear walls placed at different location in the plan. Shear walls are
generally walls made of concrete acting as a column with one dimension greater than the
other unlike columns which have comparable dimensions. The red lines denote a shear wall
in fig below.
The Shear walls prior to designing are assigned a label called PIER LABEL.
Without assigning pier label shear wall design is not possible. Generally, each shear wall has
a unique pier label number that cannot be duplicated. However, two or more walls can be
given same pier label. Giving same pier label number will mean that those walls will be
designed in similar manner.
To assign a pier label to a shear wall, first select that particular shear wall and then go to
Assign Menu > Shell/Area > Pier Label as shown in the fig below .
Clicking on Pier Label will open a dialogue box. Type the name of pier label and click on add
new name. Then clicking on Ok will give that selected shear wall a unique pier label as in fig.
Draw slabs using Draw Areas command. For providing a slab points are selected one by
one which will lie on the corners of slab. Selection of points should be done in
clockwise or anti-clockwise manner, otherwise required shape of slab will not be
obtained.
LOADING
Types of Loads
The different types of loads that can be applied to a beam or slab are as follows:
Dead Loads
Live Loads
Wind Loads
Earthquake loads
Fire tender
Sunk Loads
Temperature Loads (stresses)
Dead load is already assigned as and when one defines the material properties and the
member section. Live loads can be uniformly distributed line load or area load as defined in
IS 875 (Part II). Wind loads are assigned as per the IS code: 875-(Part-III). Earthquake
loading as per IS 1893 2002. Temperature loads are due to the stresses generated when the
temperature causes expansion or contraction in the members.
These loads have to be defined first in ETABS and then applied. To define loads:
Go to Define > Static Load Cases > Add new Load
Give Dead, Live Machine Sunk, Earthquake loads name and mention their types, select any
factor to be multiplies with the loads and for earth quake loads select the IS 1893 2002 code
option. The multiplier used is 0.95 just to make the structure somewhat economical.
The method of application of loads on the members is as follows:
For applying point loads: Select a point by clicking on it > Assign > Joint/Point Loads
Select the Load Case Name and the direction of load. For a downward point load write
negative sign prior to the load value in the Force Global Z textbox. Click on add to Existing
Loads and click OK.
For
line loads:
member
clicking on
>
Loads
applying
Select
a
beam
by
it > Assign
Frame/Line
Select Distributed load or Point load and select the type of load in Load Case Name. Choose
the appropriate options and units and type the load value
For
area loads:
member
clicking
Assign >
Loads >
applying
Select a
beam by
on it >
Shell/Area
Uniform
Select the
name as
earlier in
cases and
appropriate load value, units and direction.
Load case
defined
Static load
fill
the
Add a Story
Point
To add a new to story to the current
Loads
structure go to Edit menu > Edit Story
data >Insert story
Type the name of the new story, add required
story height, number of stories required, and
the story to be replicated. Click OK.
Select the 3D view option to visualize the
added story in the structure.
Area
Loads
dsdffd
View menu
Line
Loads
To visualize the elevation, plan and 3 dimensional view of the structure view menu is
used. It consists of other
options that assist in modelling and design of
structure.
Set 3D view, Set Plan View and
Set Elevation view are used to give a custom view of
the structure in 3D, Plan and Elevation respectively.
Set Building View Options helps to view the structure and its members in a customized
way. The various check boxes denote the various options that a user can avail. Labels
can be checked for an area, line or point objects. Reference lines and grid lines can be
displayed by checking the grid lines option. Beam lines, column lines are used to view/ hide a
beam or a column.
Set Building View Limits option helps to view a part of the building by assigning the
maximum value in the x and y axis that ought to be shown on the screen. One can also select
particular story range to be viewed using this option.
Rubber Band Zoom option helps to zoom an area by selecting that area using area
selection.
Restore
full
view helps to
restore
back
the
original view of the structure.
Select Menu
Select Menu is a drop down menu used to select the objects and members with the help
of various assisting options.
Select using Intersecting Line option gives us the benefit ot select a particular object by
drawing a line intersecting the member.
Selecting by Wall/Slab/Deck Sections helps to select a wall or a slab only. Similarly
by Line Object Type and by Area Object Type are used to select a line object or an area object
respectively.
Selection by Story Level or by Pier ID helps to select a story or a particular pier using pier
label. Invert selection is used to select an object which is not selected among some selected
objects. All selects all shapes in selection.
Get Previous Selection selects
Selection
removes
selected.
The default load combinations assume all static load cases declared as dead load to be
additive. Similarly, all cases declared as live load are assumed additive. However, each static
load case declared as wind or earthquake, or response spectrum cases, is assumed to be nonadditive with each other and produces multiple lateral load combinations. Also wind and
static earthquake cases produce separate loading combinations with the sense (positive or
negative) reversed. If these conditions are not correct, the user must provide the appropriate
design combinations.
The default load combinations are included in design if the user requests them to be included
or if no other user-defined combination is available for concrete design. Live load reduction
factors can be applied to the member forces of the live load case on an element-by-element
basis to reduce the contribution of the live load to the factored loading.
Design of Beams
In the design of concrete beams, in general, the program calculates and reports the
required areas of steel for flexure and shear based on the beam moments, shears, load
combination factors, and other criteria. All of the beams are designed for major
direction flexure, major shear and torsion only.
In designing the flexural reinforcement for the major moment at a particular section of a
particular beam, the steps involve the determination of the maximum factored moments and
the determination of the reinforcing steel. The beam section is designed for the maximum
positive and maximum negative factored moment envelopes obtained from all of the load
combinations. If torsion is present, each design moment is modified by two fictitious
moments that are the actual factored moment plus an equivalent moment due to torsion and
the actual factored moment minus an equivalent moment due to torsion. The equivalent
moment due to torsion is proportional to the torsion and the associated scale factor is a
function of the beam section aspect ratio. Negative beam moments produce top steel. In such
cases, the beam is always designed as a Rectangular section. Positive beam moments produce
bottom steel. In such cases, the beam may be designed as a Rectangular beam or a T-Beam.
For the design of flexural reinforcement, the beam is first designed as a singly reinforced
beam. If the beam section is not adequate, the required compression reinforcement is
calculated.
In designing the shear reinforcement for a particular beam for a particular set of loading
combinations at a particular station due to the beam major shear, the steps involve the
determination of the factored shear force, the determination of the shear force that can be
resisted by concrete, and the determination of the reinforcement steel required to carry the
balance. If there is any torsion, the design shear is modified by a fictitious shear that is the
actual shear force plus an equivalent shear due to torsion. If the nominal shear stress due to
the modified shear force is less than the nominal allowable shear stress, no closed hoop
torsion rebar is needed. In that case, only minimum shear link is needed. However, if torsion
is present and if the nominal shear stress due to the modified shear force is more than the
nominal allowable shear stress, closed hoop torsion rebar is calculated.
Special considerations for seismic design as required in the seismic code IS 13920:1993 are
incorporated into the program for IS 456:2000.
Design of Columns
In the design of columns, the program calculates the required longitudinal steel, or if
the longitudinal steel is specified, the column stress condition is reported in terms of a
column capacity ratio, which is a factor that gives an indication of the stress condition
of the column with respect to the capacity of the column. The design procedure for the
reinforced concrete columns of the structure involves the following steps:
Generate axial force-biaxial moment interaction surfaces for all of the
different concrete section types of the model.
Check the capacity of each column for the factored axial force and bending
moments obtained from each loading combination at each end of the column.
This step also is used to calculate the required reinforcement (if none was
specified) that will produce a capacity ratio of 1.0.
The shear reinforcement design procedure for columns is very similar to that for beams,
except that the effect of the axial force on the concrete shear capacity needs to be considered.
For certain special seismic cases, the design of columns for shear is based on the capacity
shear. The capacity shear force in a particular direction is calculated from the moment
capacities of the beams framing into the column.
To design a structure it is to be analyzed first. Go to Analyze Menu > Run Analysis
or F5
performs a few more book keeping actions that are evident on the status bar in the bottom
left-hand corner of the ETABS window. When the entire analysis process has been
completed, the model automatically displays a deformed shape view of the model, and the
model is locked. The model is locked when the Lock/Unlock Model button appears
depressed. Locking the model prevents any changes to the model that would invalidate the
analysis results.
Now, the system is analysed and one can easily see the moments acting, deflections of the
members, forces acting and deformed shape of structure.
As discussed already that design of the structure gives the area of steel required for a beam or
column. To design the structure go to Design Menu > Concrete Frame Design > Start
Design/ Check of Structure.
///The program takes some time based on the complexity of the structure and finally gives the
reinforcement required for each member of the structure. The member appear green in colour
if
its
safe
and red
colour
signifies failure either in shear or flexure. The red members need /to be modified, one can
increase the grade of concrete or the dimensions of the member or some /other suitable
changes can be made as the case requires.
The readings above the line denote top reinforcement and below the line shows bottom
reinforcement.
////The red members are failing in shear, the reading for longitudinal steel are obtained but the
members need to be reviewed in case of shear reinforcement. The summary details of the
members can be obtained by right clicking on that member to see where the member is
failing. The above detail of a member (Red) shows it is O/S (over stressed). The shear stress
is exceeding the maximum allowed (c max). The Fig shows the area of steel required at
different sections of the member just as shown in the Fig.
Design of Slabs
//Select load cases, story name and check the option for loads. After clocking on OK, the
program asks to save that file in .f2k format at a certain location. Define the location and
give the name to the file and save it.
/
WEEK 4
DESCRIPTION OF STRUCTURE
Multistory residential group housing garden isles is proposed in Noida. Various clusters of
high rise residential towers surrounded by extended basements are planned by architects. To
meet the parking requirements two basements are proposed. Numbers of floors in the towers
are G+32.
SUPER STRUCTURE
The structure can be built complying with flat slab system or the conventional framed system.
Then finalization of the beam column (framed system) is adopted after following comparison.
The cost comparison between framed structure system and the flat slab system.
The uneconomical aspects and non-feasibility of post tensioning system in this
project.
Column width of minimum 300mm to be considered in conceiving design, although to
minimize column projection in rooms and habitable spaces it tried to have shear walls of
equivalent width of walls. Peripheral beams shall be provided with maximum spacing of 6m
and beam that shall be 550mm for such cases. Placement of columns and shear walls are
made in such a way that it will not affect parking layout and drive-ways (extreme cases are
not avoidable).
EXTENDED BASEMENT
Extended basement are primarily provided for parking purpose and to household the services.
The method of construction of non-tower area has been proposed with two options.
In other direction where driveway is present, column spacing of 7.5m is provided according
to driveway width. With the column spacing as mentioned above most economical structure
can be achieved. For the roof slab of lower basement, conventional beam slab system is
adopted with primary beam of 450 X 600 mm and secondary beam of 350 X 600 mm and
slab thickness of 125mm.
For the roof slab of upper basement, conventional beam slab system is adopted with primary
beam of 450 X 675 mm and secondary beam of 350 X 650 mm and slab thickness of 225mm.
This slab is designed for self-weight, filling load of 600mm, fire tender movement (45 Tonne)
and loading of transit mixer (28 Tonne) over bare slab.
Model Generation
The building is planned as a combination of R.C.C. shear wall/ columns and beams
framed structure. After preliminary sizing of various structural members, a computer
model of the structural frame of Building will be generated for carrying out computer
analysis for the effects of vertical and lateral loads that are likely to be imposed on the
structure.
The building structure will be analyzed using ETABS software. ETABS has been thoroughly
tested validated and recognized internationally by several organization and is well suited for
the analysis of building system. Geometrical dimensions, member properties and membernode connectivity, including eccentricities will be modeled in the analysis problem. Variation
in material grades, if present, will also be considered. The permissible values of the load
factors and stresses will be utilized within the purview of the Indian standards. The computer
analysis will evaluate individual internal forces, reactions at foundation level and deflection
pattern of the entire structure and in the individual members. This data will then be used to
verify adequacy of the member sizes adopted and after further iteration arrive at the most
appropriate design of the structural members. Some re-runs of the analysis programs might be
required for arriving at the optimum structural space frame Characteristics that satisfy the
strength and stability criteria in all respects. The whole structure will be idealized as a space
frame. Beams and columns in the structure will be modeled as line members. The shear walls
and cantilever balcony slabs will be modeled as shell elements and floor slab as membrane
elements. The structure is analyzed for all possible loads i.e. gravity loads, wind and
earthquake load acting on it throughout its life span.
Control of Deflection
In order to control deflection of structural elements, the criteria given in clause 23.2 of
IS: 456:2000 is proposed to be used.
Control of Cracking
In order to avoid excessive cracking in the flexural members, maximum diameter and
spacing of the reinforcements is restricted as per the detailing rules indicated in clause
26.0.0 IS: 456:2000
Masonary Wall
Project is to be modeled on use of fly ash blocks. Density of these blocks without plaster
is 1620Kg/m3. Therefore, the structural safety of these walls is ensured by treating them
as one way / two way slab panels spanning between adjoining beams and columns.
These walls are designed as unreinforced masonry as per IS: 1905-1987 and IS: 43261993.
Expansion Joint
Expansion joint are provided in such a way that each Tower is separated from adjacent
Tower with some part of extended basement. Expansion joint will travel upto
foundation level, although no expansion joint is provided in foundation, only
compensatory strip shall be provided in foundation to minimize shrinkage stresses. The
gap between adjacent Tower shall be determined as per actual deflection multiplied by
codal recommendation given in Clause 7.11.3 of IS: 1893.
i)
ii)
iii)
iv)
v)
vi)
Density of concrete
Density of soil
Density of Steel
Density of plain concrete
Density of finishes
Steel rolled sections
Slab thickness
25 KN/cu.m
18 KN/cu.m
80 KN/cu.m
24 KN/cu.m
20 KN/cu.m
As per the section tables
(Approximate density 78.5 KN/cu.m)
- as per actual.
Flooring
- 50mm thick
- 200mm thick
Fire tender load has been considered over complete basement slab.
Retaining wall has been designed with earth pressure, fire tender as surcharge
load and water pressure.
(ii) Live Loads: - The live load of have been taken as per IS: 875 (Part-2), acting
on the floor slab. Live load has been considered in the following manner:
(a)
Basements
- 500kg/m (Vehicular
Loads)
(b)
Typical Floor
- 200 Kg/m2
(c)
Terrace
- 150 Kg/m2
(d)
Fire tender 60 tonner
- 45 Ton
(e)
Lift Machine Room/Pump Room
- 750 Kg/m2
Reduction in live load has considered as per the clause 3.2 of IS: 875 (Part- II)
(iii) Wind Load: - The wind load has been taken as per IS: 875 (Part-III) and wind
pressure calculated as :
Wind tunnel test shall be required for all the Towers
pz
Vz
Vz
K1
1.0.
K2 = Terrain, height and structure size factor, category 2 and
class C has been taken.
K3 = Topography factor = 1.0 (Plain topography)
Vb = Basic wind speed = 47m/s
Force acting on different nodes = Cf A.pz
Cf = Shape factor
A = Influence area of n node/joint on which load is applied.
pz = Designed wind pressure.
Gust factor method of IS: 875 code shall be used for assessing the wind loads. In
addition, the structures shall also be checked for the wind loads assessed from
wind tunnel tests. Critical of the two shall be used for the structural design of the
individual structural members.
(iv) Earthquake Load:- Response spectrum method is used as per IS:1893 (Part-1):
2002, with the following data.
Ah = ZI Sa
2Rg
Ah = Design horizontal seismic coefficient.
Z
been
done as per IS: 13920.
(Sa/g) is the normalized Response Spectrum value for the structure which is the
function of the fundamental time period of vibration of the structure and the type
of the founding soil the value is considered as per Geotechnical report.
(v) Load Combination:
For Foundation (for checking actual bearing stresses and foundation load)1.
(DL+ RLL) (For foundation)
2.
(DL + LL)
3.
(DL + WLX)
4.
(DL - WLX)
(DL + WLZ)
6.
(DL - WLZ)
7.
8.
9.
10.
11.
(DL + EQX)
12.
(DL - EQX)
13
(DL + EQZ)
14.
(DL - EQZ)
15.
16
17.
18.
DL+LL
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16
17.
18.
19.
20.
21.
22.
23.
24.
DL + EQX + 0.3EQZ *
25.
DL + EQX - 0.3EQZ *
26.
DL - EQX + 0.3EQZ *
27.
DL - EQX - 0.3EQZ *
28.
DL + EQZ + 0.3EQX *
29.
DL + EQZ - 0.3EQX *
30.
DL - EQZ + 0.3EQX *
31.
DL - EQZ - 0.3EQX *
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
0.9DL+ 1.5WLX
57.
58.
59.
DL
Dead Load
LL
Live Load
RLL
EQX
EQZ
WLX =
WLZ =
Materials
Concrete Grade
:-
:-
: - M-25, M-30, M-35, M-40 and M-50 grade confirming to IS: 456: 2000
used for columns & shear walls.
25 mm
40
mm
40
mm
Detailing of RCC structure will conform to IS: 456. As the structure is located in the high
seismic prone area thus for ductility requirement the guidelines of IS: 13920 shall be
followed.
Design Standards
All the relevant IS codes & specification shall be followed.
Some main codes are as follows.
a)
b)
c)
d)
e)
f)
g)
IS: 456: -2000, Code of practice for Plain and Reinforced Concrete.
IS: 875 (Part-I, II, III), Code of practice for Design loads (other than earthquake).
IS: 1893-2002 (Criteria for E/Q Resistant Design for Structure).
IS: 4326:1993 (E/Q Resistant Design & Construction of Building).
IS: 13920-1993 (Ductile Detailing of Reinforced Concrete Structures Subjected to
Seismic Forces).
SP: 16 (Design aids to IS: 456).
SP: 34 (Concrete Reinforcement & Detailing).
LOADING SHEET
Dead Load
1.
Walls Load
1.1
200mm thick wall (Fly ash blocks are used-density 1620Kg/ m3)
Height of wall (Beam Depth 550 mm)
3.1 - 0.550
Self-load
0.20 x 16.5
3.3
Plaster (12+18mm)
0.030 x 22
Total
0.66 KN/ m2
--------------------3.96 KN/ m2
---------------------
2.55m
KN/ m2
3.96 x 2.55
= 10.1 KN/m
3.1 0.550
Self -load
0.100 x 16.5
1.65
Plaster (12+15mm)
0.027 x 22
0.594 KN/ m2
----------------------
2.55m
Total
100mm Wall per Floor (Beam Depth 550)
2.244 KN/ m2
----------------------
2.244 x 2.55
KN/m
1.3
5.0KN/m
1.4
1 KN/ m2
1.5
Parapet
3 KN/ m2
2.
2.1 Basement
Floor Finish 100mm
.1 x 20
2 KN/ m2
Plaster
0.006 x 22
0.132 KN/ m2
1 KN/ m2
Total
---------------------= 3.132KN/m2
--------------------- 3.2 KN/m2
0.05 x 20
1KN/ m2
Plaster
0.006 x 22
0.132 KN/ m2
----------------------= 1.132KN/m2
----------------------------------
Total
1.2 KN/m2
0.75 x 20
1.5 KN/ m2
4 KN/ m2
2.4 Terrace
Floor Finish 50mm + Brick coba
3.
Sunk Load
3.1
3.2
Balcony 50 mm Sunk
Sunk 50mm
3.3
0.03 x 20
= 6 KN/m2
0.05 x 20
= 1 KN/m2
0.1 x 20
= 2 KN/m2
3.4
5.8
Sunk 100mm
3.5
= 2 KN/m2
4.
0.1 x 20
= 0.44 x 20
= 8.8KN/m2
= 3KN/m2
0.15 x 20
5. Staircase Loading
Loading Per Meter Width of
Waist Slab
=
0.15 x 25 x 1
Cos (33.40)
Flight
4.49 KN/ m2
0.5
x 0.184
x 0.25
x 25
(0.184
+ 0.250)
x 25
x 0.04
0.25
0.25
Step (Concrete)
Finishing
=
Total=
2.3 KN/ m2
1.74 KN/ m2
9.0 KN/ m2
So, 200mm Thick Slab Load 5.0 KN/ m2 & 4.0 KN/ m2 Floor Finish Load Shall Applied
6.
10 KN/ m2
7.
30 KN/ m2
Live Load
1.
2 KN/ m2
2.
2 KN/ m2
3.
4.
Parking (Podium)
5 KN/ m2
5.
0.75 KN/ m2
6.
2KN/ m2
3KN/ m2
= 3 KN/ m2
Helipad
Live Load
100 mm filling
0.1 x 20
2KN/ m2 (Sunk)
Floor Finish
.125 x 20
2.5KN/ m2
All units in
mm2
Comparison of Cost Between Framed Structure system & Flat Slab System
SUMMARY
S.No
A
Description
R.C.C
Slab
Beam
Column
Shuttering
Slab/Beam
Column
Reinforcement
Unit
Cum
Cum
Cum
Sqm
Sqm
Kg
OPTION 1
Framed Structure System
Quantity Rate
Amount
68.4 4200
37.8 4200
75 4500
1050
525
32292
285
285
50
Total Cost
Typical Floor Area
(Sqm)
Total Cost
Total Cost
Difference
OPTION - 2
Flat Slab System
Quantity Rate
Amount
287280.00
158760.00
337500.00
115.2
13.2
75
4200
4200
4500
483840.0
55440.0
337500.0
299250.00
149625.00
1614600.00
755
525
37136
285
285
50
21517
14962
185680
2847015.00
600
Per Sqmt
Per Sqft
WITH OPTION 1
3098380.0
600
4745.03
440.82
5163.9
479.7
38.92
SAY = Rs. 40
NOTE :- It is assumed that the cost of foundation will be same in all the two options.
Therefore, the cost of Framed Structure System is found to Rs.40 less per sqmt. than the Flat