32144 Federal Register / Vol. 71, No.

106 / Friday, June 2, 2006 / Notices

telephone at 301–415–7233, or by For further details with respect to this refueling outage. The four lead test
Internet electronic mail to action, see the application for assemblies will be placed in non-
infocollects@nrc.gov. amendment dated May 22, 2005, and limiting core locations. For subsequent
Dated at Rockville, Maryland, this 25th day the licensees’ letter dated April 20, cycles, two of the lead test assemblies
of May 2006. 2006, which withdrew the application will be placed into Byron Station, Unit
For the Nuclear Regulatory Commission. for license amendment. Documents may 2, and two lead test assemblies will
be examined, and/or copied for a fee, at remain in Byron Station, Unit 1.
Brenda Jo. Shelton,
the NRC’s Public Document Room The proposed action is in accordance
NRC Clearance Officer, Office of the Chief with the licensee’s application dated
Information Officer.
(PDR), located at One White Flint North,
Public File Area O1 F21, 11555 September 23, 2005.
[FR Doc. E6–8583 Filed 6–1–06; 8:45 am]
Rockville Pike (first floor), Rockville, The Need for the Proposed Action
BILLING CODE 7590–01–P
Maryland. Publicly available records
will be accessible electronically from Pursuant to 10 CFR 50.12, ‘‘Specific
the Agencywide Documents Access and exemptions,’’ Exelon has requested
NUCLEAR REGULATORY exemptions from 10 CFR 50.44,
COMMISSION Management Systems (ADAMS) Public
Electronic Reading Room on the Internet ‘‘Combustible gas control for nuclear
[Docket No. 50–346] at the NRC Web site, http:// power reactors,’’ 10 CFR 50.46,
www.nrc.gov/reading-rm.html. Persons ‘‘Acceptance criteria for emergency core
FirstEnergy Nuclear Operating who do not have access to ADAMS or cooling systems [EECS] for light-water
Company and FirstEnergy Nuclear who encounter problems in accessing nuclear power reactors,’’ and Appendix
Generation Corp.; Notice of Withdrawal the documents located in ADAMS K to 10 CFR part 50, ‘‘ECCS Evaluation
of Application for Amendment to should contact the NRC PDR Reference Models.’’ The regulation at 10 CFR
Facility Operating License staff by telephone at 1–800–397–4209, 50.44 specifies requirements for the
or 301–415–4737 or by e-mail to control of hydrogen gas generated after
The U.S. Nuclear Regulatory a postulated loss-of-coolant accident
Commission (the Commission) has pdr@nrc.gov.
(LOCA) for reactors fueled with
granted the request of FirstEnergy Dated at Rockville, Maryland, this 25th day zirconium-clad fuel. Section 50.46
Nuclear Operating Company and of May 2006. contains acceptance criteria for ECCS
FirstEnergy Nuclear Generation Corp. For the Nuclear Regulatory Commission.
for reactors fueled with zircaloy or
(FENOC) to withdraw its May 22, 2005, Stephen J. Campbell, ZIRLOTM clad fuel. In addition,
application for proposed amendment to Project Manager, Plant Licensing Branch III– Appendix K to 10 CFR part 50 requires
Facility Operating License No. NPF–3 2, Division of Operating Reactor Licensing, that the Baker-Just equation be used to
for the Davis-Besse Nuclear Power Office of Nuclear Reactor Regulation.
predict the rates of energy release,
Station (DBNPS), Unit 1, located in [FR Doc. E6–8581 Filed 6–1–06; 8:45 am] hydrogen concentration, and cladding
Ottawa County. BILLING CODE 7590–01–P oxidation from the metal-water reaction.
The proposed amendment would The exemption request relates solely
have revised the technical specifications to the specific types of cladding material
pertaining to a qualified alternate repair NUCLEAR REGULATORY specified in these regulations. As
criteria for axial tube end cracking COMMISSION written, the regulations presume the use
indications in the DBNPS once through [Docket Nos. STN 50–454 and STN 50–455] of zircaloy or ZIRLOTM fuel rod
steam generator tubes. Specifically, the cladding. Thus, an exemption from the
proposed amendment would revise the Exelon Generation Company, LLC; requirements of 10 CFR 50.44, 10 CFR
TS surveillance requirements for the Byron Station, Unit Nos. 1 and 2; 50.46, and Appendix K to 10 CFR part
steam generator inservice inspection to Environmental Assessment and 50 is needed to irradiate lead test
include tube end cracking alternate Finding of No Significant Impact assemblies employing AXIOMTM
repair criteria. developmental clad alloys at Byron
The Commission had previously The U.S. Nuclear Regulatory
Commission (NRC) is considering Station, Units 1 and 2.
issued a Notice of Consideration of The proposed action will use the
Issuance of Amendment published in issuance of an exemption from Title 10
irradiation of the lead test assemblies
the Federal Register on July 5, 2005 (70 of the Code of Federal Regulations (10
incorporating the developmental
FR 38720). However, by letter dated CFR) section 50.44, 10 CFR 50.46, and
cladding to provide data on fuel and
February 16, 2006, in response to 10 CFR part 50, Appendix K, for Facility
material performances to support future
Generic Letter 2006–01, ‘‘Steam Operating Licenses Nos. NPF–37 and
licensing activities.
Generator Tube Integrity and Associated NPF–66, issued to Exelon Generation
Technical Specifications,’’ FENOC Company, LLC (Exelon, the licensee), Environmental Impacts of the Proposed
committed to submit a license for operation of Byron Station, Units 1 Action
amendment application by May 31, and 2, located in Ogle County, Illinois. The NRC has completed its safety
2006, proposing to amend the DBNPS Therefore, as required by 10 CFR 51.21, evaluation of the proposed action and
TS to be consistent with TS Task Force the NRC is issuing this environmental concludes that specific application of
(TSTF)–449, ‘‘Steam Generator Tube assessment and finding of no significant the limitations on fuel cladding material
Integrity,’’ Revision 4. Since this new impact. in 10 CFR 50.44, 10 CFR 50.46, and 10
license application will be incompatible Environmental Assessment CFR part 50 Appendix K to the lead test
with the changes proposed in the earlier assemblies is not necessary for the
license amendment application, by Identification of the Proposed Action licensee to achieve their underlying
jlentini on PROD1PC65 with NOTICES

letter dated April 20, 2006, FENOC The proposed action would allow the purposes. In addition, the NRC staff has
withdrew the May 22, 2005, amendment licensee to place four lead test determined that, pursuant to 10 CFR
request. FENOC plans to resubmit the assemblies containing a limited number 50.12(a), the exemption is authorized by
license amendment application at a later of AXIOMTM fuel rods into the Byron law, will not present an undue risk to
date. Station, Unit 1, core during the fall 2006 public health and safety, and is

VerDate Aug<31>2005 18:05 Jun 01, 2006 Jkt 208001 PO 00000 Frm 00117 Fmt 4703 Sfmt 4703 E:\FR\FM\02JNN1.SGM 02JNN1