Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating,
inspection, maintenance and cleaning procedures. Write the products serial number in the back of the manual
near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and
the receipt in a safe and dry place for future reference.
ITEM 69304
PORTABLE
SPRINKLER PUMP
WARNING
When using electric pumps, basic safety
precautions should always be followed to reduce the
risk of fire, electric shock, and personal injury. Read
all instructions before using this pump!
1. This Pump has not been investigated for
use in swimming pool or marine areas.
2. Use only with clear water. Do not use
with flammable liquids such as gasoline,
chemicals or and corrosive liquids.
3. Risk of electric shock This pump is supplied
with a grounding conductor and groundingtype
attachment plug. To reduce the risk of
electric shock, connect only to a properly
grounded, grounding-type receptacle.
4. If there is danger of flooding, the electrical
connections must be taken to higher ground.
5. DO NOT IMMERSE IN WATER. This is not
a submersible pump. Use indoors only.
6. Always lock up pumps and keep
out of reach of children.
7. Wear ANSI-approved safety
goggles during installation.
Page 2
Item 69304
Grounding Instructions
To prevent electric shock and death from incorrect grounding wire
connection
Read and follow these instructions:
Check with a qualified electrician if you are
2. The grounding prong in the plug is connected through
in doubt as to whether the outlet is properly
the green wire inside the cord to the grounding
grounded. Do not modify the power cord
system in the tool. The green wire in the cord must
plug provided with the tool. Never remove the grounding
be the only wire connected to the tools grounding
prong from the plug. Do not use the tool if the power cord
system and must never be attached to an electrically
or plug is damaged. If damaged, have it repaired by a
live terminal. (See 3-ProngPlug andOutlet.)
service facility before use. If the plug will not fit the outlet,
3. The tool must be plugged into an appropriate outlet,
have a proper outlet installed by a qualifiedelectrician.
properly installed and grounded in accordance with
all codes and ordinances. The plug and outlet should
look like those in the precedingillustration.
(See 3-ProngPlug andOutlet.)
4. This pump is intended for use on a circuit that has
an outlet that looks like the one illustrated above in
125 V~ 3-Prong Plug and Outlet. The pump has
a grounding plug that looks like the plug illustrated
above in 125 V~ 3-Prong Plug and Outlet.
Grounding
Pin
Extension Cords
1. Grounded tools require a three wire extension
cord. Double Insulated tools can use either
a two or three wire extension cord.
Page 3
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD
LENGTH
25 50 75 100 150
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD
LENGTH
25 50 75 100 150
0 2.0
18
18
18
18
16
7.1 12.0
18
14
12
10
2.1 3.4
18
18
18
16
14
12.1 16.0
14
12
10
3.5 5.0
18
18
16
14
12
16.1 20.0
12
10
5.1 7.0
18
16
14
12
12
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V~
A
Specifications
Electrical Rating
Maximum Flow
Maximum Suction Lift
Maximum Delivery Height
Pressure
Inlet and Outlet Diameter
Power Cord Length
Page 4
120 V~ / 60 Hz / 10 A
1215 GPH
26 FT.
147 FT.
71 PSI
1 IN. NPT
6 FT.
Item 69304
Set up
WARNING! This is NOT a submersible pump. Do not immerse in water.
Pipe Connection
The Pump uses 1" NPT piping (sold separately).
Purchase the necessary length of pipe, including any
needed fittings and bends. Mount the Pump as close
to the source of water as possible and within the
range of the rated Suction Lift. The connections must
be airtight. Wrap all threaded connections with PTFE
tape (sold separately).
1. Remove the Inlet and Outlet Covers from the Pump.
Outlet
Power Switch
Inlet
Pump Body
Operation
To prevent electric shock and death:
Make sure that the Terminal Box Cover is properly
closed and sealed before priming or operation.
Note: A foot valve on the inlet connection is critical
to help prevent the pump from losing prime.
Bucket
full of
clean
water
im
Y-fitting
in
Ho
se
Outlet Pipe
Inlet Pipe
Pump
Foot
Valve
Item 69304
Page 5
Storage
1. If you will not be using the Pump for an extended
period of time, drain the Pump Body. First disconnect
both the suction and outlet lines, then tip the pump
so that all the water is drained from the pump cavity.
Troubleshooting
Problem
Possible Causes
Motor will
not start.
Motor runs
but water isnt
pumping.
Excessive noise
orrattling.
Likely Solutions
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power
supply before service.
Item 69304
Description
Qty
Bolt M8*14
Spring Washer 8
Washer 8
Pump Support
Bracket For Pump Support
Column Tie Bolt M6*12
Priming Plug
O-Ring 8.2*1.9
Pump Casing
O-Ring 26.3*2.2
Venturi Tube
Baffle
Diffuser
Hex Nut 10
Spring Washer 10
Washer 10
Impeller
O-Ring 163*3.55
Mechanical Seal
Seal Holder
Seal
Pump Support
Cover
Bolt M4*8
32
31
Item
2
2
2
1
2
8
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
33
30
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
36
35
34
1
Item 69304
Qty
37
38
39
1
1
1
1
1
1
2
1
1
1
1
1
4
4
1
1
1
1
1
1
1
1
2
40
41
42
43
44
45
46
30
29
28
27
26
25
23
24
7 8
Description
Cord Clip
Bolt M4*6
Spring Washer 4
Terminal
Fixing Washer
Cable Holder
Ball Bearing 6202-Zz/Z2
Shaft Key A4*10
Rotor
Wave Spring
Motor Stator
End Plate
Washer 5
Bolt M5*138
Fan
Fan Cover
Power Cord
Sealing Ring For Terminal
Power Switch
Sealing Washer For Switch
Capacitor 40f/250V
Terminal Box
Screw
47
10
14 15
1 1 12 1 3
18 19
16 17
2 0 2 1 22
Page 7
3491 Mission Oaks Blvd. PO Box 6009 Camarillo, CA 93011 (800) 444-3353