Você está na página 1de 1

2

5170

5170

10340

5170

5170

PROJECTION
GROUT

15510

100

100

100

100

100

WASHER PLATE
SQUARE HOLES

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

EMBEDMENT

TYPICAL HD BOLT ELEVATION

200

WASHER PLTS

20*450Lg 8.8SQSQOX

FLT10*100*100

PROJ EMBEDMENT GROUT


100

350

25

NOTES:
1. Permanent master guidelines and datums to be established by the Main
Contractor and maintained throughout the erection programme.

102

150

150

4. Top of concrete to be smooth and level.


5. The Permitted plan deviations of erected components demand the overall
length / width for buildings up to 30m shall be within 20mm. For
buildings in excess of 30m, the deviation shall be 20mm +0.25mm/m
(L-30), where 'L' is length in metres.
The set out of the overall master grid lines should make due allowance
for the above.

13623

1200

75

3. Bases, excavations and the site to be kept clear of standing water.

1983

150

75
5303

150

1400

152

200

1200

*
102

20

HD BOLTS

2. All setting out to be with a steel tape.

1200

QTY

PERMITTED DEVIATION FOR FOUNDATIONS:

15607

U
T. B2
O 03
.C *
. - 13
30 3*
0 25
m
m

1200

BP1

1400

150

200

152

1400

152

200

1200

303

200

200

303
150

1400

152

15607

200

200

BASE TYPE

PRESET FOUNDATION BOLT OR BOLT GROUPS


WHEN PREPARED FOR ADJUSTMENT
D
A

1200

150

4500

150

U
T. B2
O 03
.C *
. - 13
30 3*
0 25
m
m

A = +25mm to -5mm
B = +0 to -30mm
C = 20mm
D = 25mm minimum

C
NOTES:
1. All packets to be 75mm diameter (tapered).

800
8323

1040
7283

75
75

Concrete mix to be C20 with a 50mm slump


It is important that base sizes shown are adhered
to as these are the minimum sizes required in the
building design.
The building has been desinged to the standards
laid down in BS5502 Part 1 Section 1.2
Building is Class 2. Basic wind velocity allowed for
in the design is 46m/ s.
Ground Roughness category is SL -0.15 and SA -0.07
Design is for altitude up to 200m and the bearing
capacity of the ground is assumed to be 150k/ N.

4500
75

303

75

100

1400

100

1400

152

200

150

200

200

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

152

100

1200

200

100

102

Setting out dimensions for concrete panels.

200

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

1400

100

152

200

1400

150

100

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

U
T. B3
O 05
.C *
. - 16
30 5*
0 40
m
m

100

150

1983

1983

150

1200

150

303

200

Base Type 1 - 1400mm x 1200mm x 750mm deep


Base Type 2 - 1200mm x 1200mm x 750mm deep
1.4 x 1.2 x 0.75 = 1.26m x 12 = 15.12m
1.2 x 1.2 x 0.75 = 1.08m x 8 = 8.64m
Total Concrete Required
= 23.76m

1200

152

200
0

Foundation Elevation -300 except as noted.

U
T. B2
O 03
.C *
. - 13
30 3*
0 25
m
m

150

5303

100

Base Plan

6483

1200

102

15910 Span o/ all columns

75
75

9123

1200

75

5303

102

6. Pockets to be kept clear of debris, and bolt threads lubricated.

800

75

U
T. B2
O 03
.C *
. - 13
30 3*
0 25
m
m

75

nt
ce
3
00
22

U
T. B2
O 03
.C *
. - 13
30 3*
0 25
m
m

150

75

150

150

5. All steelwork below slab level to be adequatley protected by others.

U
T. B2
O 03
.C *
. - 13
30 3*
0 25
m
m

s
re

5000

102

4. DO NOT grout in H.D. Bolts until all steelwork has been


plumbed, lined and levelled.

3840

150

of

co

75

lu
m

ns

75

1200

150

U
T. B2
O 03
.C *
. - 13
30 3*
0 25
m
m

150

3. To ensure that the bolts remain free to move, they are to be


loosened again after the concrete sets.

U
T. B2
O 03
.C *
. - 13
30 3*
0 25
m
m

1200

75

10303

75

2. H.D. Bolts to be anchored loose in pockets by the Main Contractor.

By
1200

1200

1200
5440

REV MARK

Date
CREATED

DESCRIPTION

By

Date

CHECKED

Adrian Williams
Cattlegate Farm, Enfield EN2 8AU

Tekla Structures

Plan On Foundations

15510

3100

12410

1070

11340

1000

10340

1000

9340

1170

8170

3000

5170

5170

DRAWING TITLE
CONTRACT

Erection - Base Plan


Evaporation Building

MODELLED BY

CadMonkey

DATE

CONTRACT NO
DRAWING No

1532
G [4]

SCALE
REVISION No.

24.06.2015
1:40

Você também pode gostar