Você está na página 1de 17

PROFILE FOR STORAGE ARRAY: MD3000 (Wed Jul 01 14:32:20 BRT 2015)

SUMMARY-----------------------------Number of RAID controller modules: 2


Number of disk groups: 1
RAID 6: Enabled
Total number
Number of
Number of
Total number

of virtual disks used:


standard virtual disks:
access virtual disks:
of virtual disks allowed:

2
1
1
256

Snapshot Virtual Disks:


Number of snapshots used:
Number of snapshots allowed:
Number of snapshots allowed per source virtual disk:

Disabled
0
0
0

Virtual Disk Copy:


Disabled
Number of copies used:
0
Number of copies allowed: 0
Number of physical disks:
Mixed physical disk types:
Current physical disk type(s):
Total hot spare physical disks:
Standby:
In use:

10
Enabled
Serial Attached SCSI (SAS) (10)
0
0
0

Number of expansion enclosures:


0
Number of expansion enclosures allowed: 2
Storage Partitioning:
Enabled
Number of partitions used:
1
Number of partitions allowed: 4
Number of virtual disks allowed per partition: 256
Access virtual disk: LUN 1,2 (see Mappings section for details)
Default host OS:
index 0)
mware
Current configuration
Firmware version:
NVSRAM version:
EMW version:
AMW version:

Windows Server 2003/Server 2008 Non-Clustered (Host OS

07.35.31.60
N133X-735890-005
03.35.G6.50
03.35.G6.50

Pending configuration
Staged firmware download supported:
Firmware version:
NVSRAM version:
Transferred on:
RAID Controller Module enclosure audible alarm:
NVSRAM configured for batteries:

Yes
None
None
None
Disabled

Yes

Start cache flushing at (in percentage): 80


Stop cache flushing at (in percentage): 80
Cache block size (in KB):
4

ico

Media scan frequency (in days): 15


Failover alert delay (in minutes): 5
Feature enable identifier: 30350000000030350000000047062AC6
Feature pack: Basic
Feature pack submodel ID: 39
Storage array world-wide identifier (ID): 6001C23000B80FBC0000000046C22D06
CONTROLLERS-----------------------------Number of RAID controller modules: 2
RAID Controller Module in Enclosure 0, Slot 0
Status:
Current configuration
Firmware version:
Appware version:
Bootware version:
NVSRAM version:
Pending configuration
Firmware version:
Appware version:
Bootware version:
NVSRAM version:
Transferred on:
Replacement part number:
Model name:
Board ID:
Submodel ID:
Product ID:
Revision:
Replacement part number:
Part number:
Serial number:
Vendor:
Date of manufacture:
Data Cache
Total present:
Total used:
Processor cache:
Total present:

Online
07.35.31.60
07.35.31.60
07.35.31.60
N133X-735890-005
None
None
None
None
None
Not Available
133X
1331
39
MD3000
0735
0XR277
77A000S
DELL
July 10, 2007
310 MB
0 MB
202 MB

Host Interface Board


Status:
Location:
Type:
Number of ports:
Board ID:
Replacement part number:
Part number:
Serial number:
Vendor:
Date of manufacture:
Date/Time:

Not Present
Slot 1
Unknown
0
Not Available
Not Available
Not Available
Not Available
Not Available
Not available
Wed Jul 01 14:33:44 BRT 2015

Associated Virtual Disks (* = Preferred Owner):


LUN0*
RAID Controller Module DNS/Network name:
Remote login:
Ethernet port:
Link status:
MAC address:
Negotiation mode:
Port speed:
Duplex mode:
Network configuration:
IP address:
Subnet mask:
Gateway:

target
Disabled

1
Up
00:1c:23:b8:0f:be
Manual setting
100 Mbps
Full duplex
Static
192.168.210.238
255.255.255.0
192.168.210.253

Physical Disk interface:


Channel:
Port:
Status:
Maximum data rate:
Current data rate:

SAS
1
Expansion
Up
3 Gbps
3 Gbps

Physical Disk interface:


Channel:
Port:
Status:
Maximum data rate:
Current data rate:

SAS
2
Expansion
Up
3 Gbps
3 Gbps

Host interface:
Channel:
Port:
Status:
World-wide identifier:
Maximum data rate:
Current data rate:
Part type:

Sas
1
0, 0
Up
50:01:c2:34:b8:0f:be:04
3 Gbps
3 Gbps
C1068
revision 1,588,992

RAID Controller Module in Enclosure 0, Slot 1

Status:

Online

Current configuration
Firmware version:
Appware version:
Bootware version:
NVSRAM version:
Pending configuration
Firmware version:
Appware version:
Bootware version:
NVSRAM version:
Transferred on:
Replacement part number:
Model name:
Board ID:
Submodel ID:
Product ID:
Revision:
Replacement part number:
Part number:
Serial number:
Vendor:
Date of manufacture:
Data Cache
Total present:
Total used:
Processor cache:
Total present:
Host Interface Board
Status:
Location:
Type:
Number of ports:
Board ID:
Replacement part number:
Part number:
Serial number:
Vendor:
Date of manufacture:
Date/Time:

07.35.31.60
07.35.31.60
07.35.31.60
N133X-735890-005
None
None
None
None
None
Not Available
133X
1331
39
MD3000
0735
0XR277
77A0005
DELL
July 10, 2007
310 MB
0 MB
202 MB
Not Present
Slot 2
Unknown
0
Not Available
Not Available
Not Available
Not Available
Not Available
Not available
Wed Jul 01 14:33:32 BRT 2015

Associated Virtual Disks (* = Preferred Owner): None


RAID Controller Module DNS/Network name:
Remote login:
Ethernet port:
Link status:
MAC address:
Negotiation mode:
Port speed:
Duplex mode:
Network configuration:
IP address:
Subnet mask:
Gateway:

target
Disabled

1
Up
00:1c:23:b8:0f:bc
Manual setting
100 Mbps
Full duplex
Static
192.168.100.47
255.255.255.0
192.168.201.254

Physical Disk interface:


Channel:
Port:
Status:
Maximum data rate:
Current data rate:

SAS
1
Expansion
Up
3 Gbps
3 Gbps

Physical Disk interface:


Channel:
Port:
Status:
Maximum data rate:
Current data rate:

SAS
2
Expansion
Up
3 Gbps
3 Gbps

Host Interface(s): Unable to retrieve latest data; using last known state.
Host interface:
Channel:
Port:
Status:
World-wide identifier:
Maximum data rate:
Current data rate:
Part type:

Sas
1
0, 0
Up
50:01:c2:34:b8:0f:bc:04
3 Gbps
3 Gbps
C1068
revision 1,588,992

DISK GROUPS-----------------------------Number of disk groups: 1


Name:

LUN0

Status:

Optimal

Capacity
RAID level:

2.727 TB
5

Physical Disk type:


Serial Attached SCSI (SAS)
Enclosure loss protection: No
Current owner:

RAID Controller Module in slot 0

Associated virtual disks and free capacity


Virtual Disk Capacity
LUN0
2.727 TB

Associated physical disks - present (in piece order)


Enclosure
0
0

Slot
9
10

0
0
0
0

11
12
13
14

STANDARD VIRTUAL DISKS-----------------------------SUMMARY


Number of standard virtual disks: 1
See other Virtual Disks sub-tabs for premium feature information.
NAME STATUS CAPACITY RAID LEVEL DISK GROUP DRIVE TYPE
LUN0 Optimal 2.727 TB 5
LUN0
SAS
DETAILS
Virtual Disk name:

LUN0

Virtual Disk status:

Optimal

Capacity:

2.727 TB

Virtual Disk world-wide identifier: 60:01:c2:30:00:b8:0f:be:00:00:44:a7:4


f:fd:59:49
Subsystem ID (SSID):
0
Associated disk group:

LUN0

RAID level:

Physical Disk type:

Serial Attached SCSI (SAS)

Enclosure loss protection:

No

Preferred owner:

RAID Controller Module in slot 0

Current owner:

RAID Controller Module in slot 0

Segment size:
128 KB
Capacity reserved for future segment size changes: Yes
Maximum future segment size:
2,048 KB
Modification priority:
High

Read cache:
Write cache:
Write cache without batteries:
Write cache with mirroring:
Flush write cache after (in seconds):
Dynamic cache read prefetch:

Enabled
Enabled
Disabled
Enabled
10.00
Enabled

Enable background media scan:


Media scan with consistency check:

Enabled
Enabled

Pre-Read consistency check:

Disabled

MISSING VIRTUAL DISKS-----------------------------Number of missing virtual disks: 0


DRIVES-----------------------------SUMMARY
Number of physical disks: 10
Current physical disk types: Serial Attached SCSI (SAS) (10)
BASIC:
TRAY, SLOT STATUS
FIRMWARE VERSION
0, 5
Optimal
ES64
0, 6
Optimal
ES64
0, 7
Optimal
ES64
0, 8
Optimal
ES64
0, 9
Optimal
ES62
0, 10
Optimal
ES62
0, 11
Optimal
ES62
0, 12
Optimal
ES62
0, 13
Optimal
ES62
0, 14
Optimal
ES62

CAPACITY

TYPE CURRENT DATA RATE PRODUCT ID

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

558.912 GB SAS

3 Gbps

ST3600057SS

DRIVE CHANNELS:
TRAY, SLOT PREFERRED CHANNEL REDUNDANT CHANNEL
0, 5
2
1
0, 6
1
2
0, 7
2
1
0, 8
1
2
0, 9
2
1
0, 10
1
2
0, 11
2
1
0, 12
1
2
0, 13
2
1
0, 14
1
2

HOT SPARE COVERAGE:


The following disk groups are not protected: LUN0
Total hot spare physical disks: 0
Standby: 0
In use: 0
DETAILS
Physical Disk at Enclosure 0, Slot 5
Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Unassigned
558.912 GB
558.412 GB
50:00:c5:00:3a:79:1b:63:00:00:00:00:00:00:00:00
None

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES64
6SL10BM5
SEAGATE
June 10, 2011

Physical Disk at Enclosure 0, Slot 6


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Unassigned
558.912 GB
558.412 GB
50:00:c5:00:3a:79:03:3f:00:00:00:00:00:00:00:00
None

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES64
6SL0Z7YH
SEAGATE
June 10, 2011

Physical Disk at Enclosure 0, Slot 7


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Unassigned
558.912 GB
558.412 GB
50:00:c5:00:28:b2:6d:1b:00:00:00:00:00:00:00:00
None

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES64
3SL1M07E
SEAGATE
December 8, 2010

Physical Disk at Enclosure 0, Slot 8


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Unassigned
558.912 GB
558.412 GB
50:00:c5:00:28:b1:23:97:00:00:00:00:00:00:00:00
None

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES64
3SL1LFQ1
SEAGATE
December 8, 2010

Physical Disk at Enclosure 0, Slot 9


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:

Assigned
558.912 GB
558.412 GB
50:00:c5:00:23:2b:37:ab:00:00:00:00:00:00:00:00

Associated disk group:

LUN0

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES62
3SL0L3B4
SEAGATE
May 12, 2010

Physical Disk at Enclosure 0, Slot 10


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Assigned
558.912 GB
558.412 GB
50:00:c5:00:23:2a:de:9b:00:00:00:00:00:00:00:00
LUN0

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES62
3SL0KX46
SEAGATE
May 12, 2010

Physical Disk at Enclosure 0, Slot 11


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Assigned
558.912 GB
558.412 GB
50:00:c5:00:23:2a:99:ab:00:00:00:00:00:00:00:00
LUN0

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:

15,015 RPM
3 Gbps

Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

ST3600057SS
ES62
3SL0LE6M
SEAGATE
May 12, 2010

Physical Disk at Enclosure 0, Slot 12


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Assigned
558.912 GB
558.412 GB
50:00:c5:00:23:2a:d0:b3:00:00:00:00:00:00:00:00
LUN0

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES62
3SL0KJ4H
SEAGATE
May 12, 2010

Physical Disk at Enclosure 0, Slot 13


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Assigned
558.912 GB
558.412 GB
50:00:c5:00:23:2a:27:0b:00:00:00:00:00:00:00:00
LUN0

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES62
3SL0KWVD
SEAGATE
May 11, 2010

Physical Disk at Enclosure 0, Slot 14


Status:

Optimal

Mode:
Raw capacity:
Usable capacity:
World-wide identifier:
Associated disk group:

Assigned
558.912 GB
558.412 GB
50:00:c5:00:23:2b:9b:87:00:00:00:00:00:00:00:00
LUN0

Physical Disk path redundancy: OK


Physical Disk type:
Serial Attached SCSI (SAS)
Speed:
Current data rate:
Product ID:
Firmware version:
Serial number:
Vendor:
Date of manufacture:

15,015 RPM
3 Gbps
ST3600057SS
ES62
3SL0KGKV
SEAGATE
May 12, 2010

DRIVE CHANNELS---------------------------SUMMARY
CHANNEL PORT
STATUS
1
Expansion Optimal
2
Expansion Optimal
DETAILS
DRIVE CHANNEL 1
Port: Expansion
Status: Optimal
Max. Rate: 3 Gbps
Current Rate: 3 Gbps
Rate Control: Switched
DRIVE COUNTS
Total # of attached physical disks: 10
Connected to: 0
Attached physical disks: 10
Expansion enclosure: 0 (10 physical disks)
CUMULATIVE ERROR COUNTS
RAID Controller Module 0
Baseline time set:
2/8/15 12:16:13 PM
Sample period (days, hh:mm:ss):
143 days, 06:47:26
RAID Controller Module detected errors: 4
Physical Disk detected errors:
4
Timeout errors:
0
Total I/O count:
782223068
RAID Controller Module 1

Baseline time set:


2/8/15 12:16:13 PM
Sample period (days, hh:mm:ss):
143 days, 06:47:26
RAID Controller Module detected errors: 0
Physical Disk detected errors:
0
Timeout errors:
0
Total I/O count:
0
DRIVE CHANNEL 2
Port: Expansion
Status: Optimal
Max. Rate: 3 Gbps
Current Rate: 3 Gbps
Rate Control: Switched
DRIVE COUNTS
Total # of attached physical disks: 10
Connected to: 1
Attached physical disks: 10
Expansion enclosure: 0 (10 physical disks)
CUMULATIVE ERROR COUNTS
RAID Controller Module 0
Baseline time set:

2/8/15 12:16:13 PM

Sample period (days, hh:mm:ss):

143 days, 06:47:26

RAID Controller Module detected errors: 11


Physical Disk detected errors:

Timeout errors:

Total I/O count:

771385319

RAID Controller Module 1


Baseline time set:

2/8/15 12:16:13 PM

Sample period (days, hh:mm:ss):

143 days, 06:47:26

RAID Controller Module detected errors: 0


Physical Disk detected errors:

Timeout errors:

Total I/O count:

ENCLOSURES-----------------------------RAID Enclosure 0 Overall Component Information

Enclosure audible alarm:

Disabled

Enclosure path redundancy:


Current physical disk types:
Part number:
Serial number:
Vendor:
Date of manufacture:
Asset tag:
Chassis name:
Service tag:

OK
SAS
Not Available
55GQGD1
DELL
Not Available
Not Available
MD3000
55GQGD1

Batteries Detected: 2

Battery status:
Location:
Age:
Days until replacement:
Last learn cycle:
Next learn cycle:
Weeks between learn cycles:
Part number:
Serial number:
Vendor:
Date of manufacture:

Optimal
RAID Controller Module 0
1,803 days
Not applicable
April 18, 2015
July 18, 2015
13
PN JY200
SN 0471176J1351
VN DELL
June 1, 2007

Battery status:
Location:
Age:
Days until replacement:
Last learn cycle:
Next learn cycle:
Weeks between learn cycles:
Part number:
Serial number:
Vendor:
Date of manufacture:

Optimal
RAID Controller Module 1
1,803 days
Not applicable
April 18, 2015
July 18, 2015
13
PN JY200
SN 0471176J1374
VN DELL
June 1, 2007

Power Supply/Cooling Fan Modules Detected: 2

Power Supply/Cooling Fan module 2 status: Optimal


Part number:
0MX838A00
Serial number:
CN179727760D7F
Vendor:
DELL
Date of manufacture:
Not Available
Power Supply/Cooling Fan module 1 status: Optimal
Part number:
0MX838A00
Serial number:
CN179727760D7C
Vendor:
DELL
Date of manufacture:
Not Available

Power Supplies Detected: 2

Power supply status:


Location:
Part number:
Serial number:
Vendor:
Date of manufacture:

Optimal
Power supply module (right)
0MX838A00
CN179727760D7F
DELL
Not Available

Power supply status:


Location:
Part number:
Serial number:
Vendor:
Date of manufacture:

Optimal
Power supply module (left)
0MX838A00
CN179727760D7C
DELL
Not Available

Fans Detected: 4

Fan Status: Optimal


Location:
Fan module (left)
Fan Status: Optimal
Location:
Fan module (left)
Fan Status: Optimal
Location:
Fan module (right)
Fan Status: Optimal
Location:
Fan module (right)

Temperature Sensors Detected: 4

Temperature sensor status: Optimal


Location:
Power Supply/Cooling Fan module 1
Temperature sensor status: Optimal
Location:
Power Supply/Cooling Fan module 2
Temperature sensor status: Optimal
Location:
RAID Controller Module 0
Temperature sensor status: Optimal

Location:

RAID Controller Module 1

MAPPINGS (Storage Partitioning - Enabled (1 of 4 used))------------------Virtual Disk Name


LUN RAID Controller Module Accessible by
Disk status
Access Virtual Disk 2
0,1
Host Group DMZ

Virtual
Optimal

Access Virtual Disk 1

0,1

Host Group vmware4 Optimal

LUN0

Host Group vmware4 Optimal

TOPOLOGY DEFINITIONS

STORAGE ARRAY
Default type:

Windows Server 2003/Server 2008 Non-Cluste

red
Default Group

Host Group:

DMZ

Host Group:

vmware4

Host:

vmware4

Host type:

Linux

Host port identifier: 5d:4a:e5:20:7c:e5:fe:00


Alias:
Host type:

vm0
Linux

Host port identifier: 5d:4a:e5:20:7c:e5:fe:01


Alias:

dmz0

NVSRAM HOST TYPE DEFINITIONS


NOTE: The following indexes are not used: 3 - 15
HOST TYPE

AVT STATUS ASSOCIATED INDEX

Linux
Disabled
Windows Server 2003/Server 2008 Clustered
Disabled
Windows Server 2003/Server 2008 Non-Clustered Disabled

1
2
0 (Default)