InstituteforHealthcareImprovement:FailureModesandEffectsAnalysisToolProcessDataReport
FailureModesandEffectsAnalysis(FMEA)Tool
2009FMEA
AustinMedicalCenter
Rochester,Minnesota,UnitedStates
HospitalCommunity
Aim:YearlyFMEA
ProcessData
Date:01/13/2010
Step
Description
PatientEntersClinic
FailureMode
Causes
Effects
Pt.registeredunderwrong
name
Misspelling
Wrongchartisretrieved
72 TwoidentifiersDOBand
Name
Patientisanoshow
Various
Patientdoesn'tgettreatment
30 Confirmappointments
Step
Description
PatientSeesProviderUC/ED
FailureMode
Causes
Effects
Patientgetswrongdiagnosis
Providerexamnotaccurate
Wrongtests,medications,
treatmentordered
Wrongpatient
Registrationfailstoverify
patient
Wrongchartusedforpatient
history
Step
Description
PatientisScheduledforLaborXray
FailureMode
Causes
Effects
Labsampleistoosmall
Notenoughbloodorurine
collected
Notalltestscanberunthat
providerordered.Patient
getsincompletecare.
42 Nurseorlabcanverify
samplesizemeetsmin
requirementsbeforeletting
patientleave.
Xray/CT/MRIscanisnot
clear
Patientmovedduringexam
Radiologyorprovidercannot
makeaccuratediagnosis
54 TechscanQCscansbefore
lettingpatientleave
radiology
Patientdoesn'tshowupfor
lab/xraytestsorF/U
Various
Notestsarecompleted
24 Bringlab/xraystaffto
examroomsopatientcan
notleavebeforetheyare
complete
Step
Description
PatientLeavesUC/ED(beforeresultsareback)
FailureMode
Causes
Effects
UC/EDproviderintendsfor
patienttofollowupwith
primarycareprovider.But
patientdoesn'thaveone.
InsufficientaccesstoPC/FP
Patientwillnotgetfollowup
onresultsoftests
336 ConfirmifpatienthasaPC
provider.Ifnotsystemin
placeforUC/EDproviderto
handlefollowup.
ResultssenttoUC/ED(from
lab/rad),butcopiesdon't
print(technicalreasons)
ITissuesorwrongnumber
onfax
Resultsarenotavailablefor
providerinUC/ED
60 Visualcuestoletproviders
knowwhichpatientshave
pendingresultstheyshould
belookingfor.
HISProcessforwardsresults Providermaynotbefamiliar
toprovideroncall
withpatient
Oncallproviderbelieves
someoneelsehasfollowed
upalready.
210
Oncallproviderdoesnot
followupwhentheysee
resultscomeintotheirtask
list.
Patienthadtestsdonein
UC/EDbutresultscamein
aftertheorderingprovider
hasleftandpatienthasnot
PCprovider.Theresultsare
forwardedtooncallprovider
asataskforfollowup.
Oncallproviderhadno
contactwithpatient.Needsto
readcharttoknowhowto
interpretresultsand
determineappropriatefollow
up.Timedemandsononcall
providerarealreadyhigh,
andthisisatimeconsuming
task.
448 Redesignfollowupsystemto
reducethenumberoftasks
thatgotooncallprovider
forpatientstheydidnot
encounterorwhodonot
haveaPCprovider.Improve
PCaccess.Haveprocessto
assignPCprovidertoUC/ED
patients.
ResultsareprintedinUC/ED
afterpatientleaves.The
resultsareoverlooked.
Providersandnursesget
busy,manypapersmaybe
inthearea.
Resultsarenotactedupon
Step
Description
Patientnotadmitted/goeshome
60 Systemforresultstobe
sortedanddeliveredto
nurse/providerteam.
CalculatedTotals
http://app.ihi.org/Workspace/tools/fmea/ProcessDetailDataReport.aspx?ToolId=10010&ScenarioId=11602&Type=1
1/2
9/14/2015
InstituteforHealthcareImprovement:FailureModesandEffectsAnalysisToolProcessDataReport
TotalRiskPriorityNumberfortheprocess
1584
Occ: LikelihoodofOccurrence(110)
Det: LikelihoodofDetection(110)
NOTE: 1=VerylikelyitWILLbedetected
10=VerylikelyitWILLNOTbedetected
Sev: Severity(110)
RPN:RiskPriorityNumber(OccDetSev)
Annotation
None
http://app.ihi.org/Workspace/tools/fmea/ProcessDetailDataReport.aspx?ToolId=10010&ScenarioId=11602&Type=1