Você está na página 1de 3

Accessories / 4AM and 7XR

SIPV6-111.eps

SIPV6-110.eps

SIPV6-112.eps

SIPV6-109.eps

SIPV6-108.eps

4AM auxiliary current transformers, 7XR95 isolating transformers

3
4AM5, without varistor
Fig. 13/6

4AM5, with varistor

7XR9513

7XR9515

7XR9516

Auxiliary 4AM current and 7XR isolating transformers

Overview
Application

Comment

Matching
current
transformer

Multi-tap aux. current transformer to match different current transformer ratios.


4AM51 70-7AA: Standard version, primarily for transformer differetial protection.

HKG

4AM52 72-2AA: Version with double thermal withstand capability, e.g. when
connecting to wide-range current transformer
(continuous rating 2 IN).

HKG

4AM52 72-3AA: Version with higher saturation factor (mainly for the busbar
differential protection).
Greater overcurrent factor because of higher voltages

HKG

Input and matching current transformer for phase selective busbar differential
protection (a.o. for 7SS60, 7UT6)
4AM51 20-1DA: For 1 A C.T.s
4AM51 20-2DA: For 5 A C.T.s 1)

3-phase
summation
input C.T.

Input 3-phase summation current transformer for busbar differential protection


(a.o. for 7SS60).
4AM51 20-3DA: For 1 A C.T.s
4AM51 20-4DA: For 5 A C.T.s

HKG
HKG

for line differential protection (a.o. for 7SD600)


4AM49 30-6DA: For 5 A
4AM49 30-7DA: For 1 A

HKG
HKG

HKG
fN = 45 to 60 Hz
with varistor

fN = 45 to 60 Hz
with varistor

HKD
HKD

7XR9 513: For differential protection with 1 pair of pilot wires


(a.o. for 7SD600)

HKG

20 kV insulation

7XR9 515: For differential protection with 1 pair of pilot wires


(a.o. for 7SD600)

HKG

5 kV insulation

7XR9 516: For communication converter 7XV5662-0AC00


(a.o. for SIPROTEC 4 device 7SA522, 7SA6, 7SD52, 7SD61)

Suitable for tripping coils with IN 0.5 A or 1 A, VN 40 V or 20 V, P 20 VA.


Isolating
transformer

HKG

Unlike transducers, no
dened rated power or
class accuracy required.
fN = 45 to 60 Hz

Auxiliary current transformer for C.T. powered trip coils in stations where
no battery supply can be made available.
4AM50 65-2CB: For 1 A C.T.s
4AM50 70-8AB: For 5 A C.T.s

Numerous ratios can


be selected using
terminal connections
(next page)
fN = 45 to 60 Hz

fN = 45 to 60 Hz
with varistor

Input and
matching
current
transformer

Aux. C.T. for


C.T. powered
tripping
circuits

Climatic requirements Features


according to former
DIN 40040

9
10
11

Isolating transformer for pilot wire differential protection.


Provides galvanic isolation between pilot wires and relays.

Climatic requirements:

20 kV insulation

12
13

HKG = 25 C to +125 C relative humidity max. 75 %; annual average < 65 % on 60 days of the year up to 85 %
(uniformly distributed over the year); condensation not permissible
HKD = 25 C to +125 C relative humidity max. 90 %; annual average < 80 % on 30 days of the year up to 100 %
(uniformly distributed over the year); condensation permissible

14

1) If increased thermal withstand is required type 4AM51 20-4DA is recommended.

15
Siemens SIP Edition No. 7 13/7

Accessories / 4AM and 7XR


4AM auxiliary current transformers, 7XR isolating transformers
Order No. and technical data

Order No.

Windings of auxiliary current transformers


Number of windings

F
7

G H
16

K
6

Weight, approx.

M
6 12

Z
1736

28
0.23

28
0.46

28
0.69

28
1.38

6.5
(5.6)

0.2
400

C D
10

G H
30

15

Max. current, continuously A 4.5


Max. voltage
V 1.15

4.5
2.3

4.5
3.5

4.5
7

1.2
(20)

Number of windings
(in relation to each other)
Rated current IN1)
A
Max. voltage
V

G H
16

4AM52 72-2AA00-0AN2

Rated current IN1)


Max. voltage

4AM52 72-3AA00-0AN2
4MA50 65-2CB00-0AN2

4AM49 30-6DB00-0AN2

Max. current, continuously A


Max. voltage
V
Number of windings

B
5

K L M
30 30 60

1.9 kg
Z

1736

4AM49 30-7DB00-0AN2

4AM51 70-7AA00-0AN2

N O
7

1
32

5
2

5
4

5
14

1
32

3.6 kg

10
14

2
32

10
2

10
4

10
14

2
32

5.4 kg

5
28

1
64

5
4

5
8

5
28

1
64

5.4 kg

5
2

5
4

5
14

A
V

10
2

10
4

Rated current IN1)


Max. voltage

A
V

5
4

5
8

Rated current IN1)


Number of windings

Rated current IN1)


Number of windings

K a La K b Lb
110
110

88

ka

A
A

1.25
5

88

ka

Q
16

2.9 kg

Secondary windings

lb

2.9 kg
Primary windings

K c Lc K d L d
22
22

la

88

kb

1.25

1.25

K a La K b L b
22
22

Number of windings

88

kb

Primary windings

Kc L c Kd L d
110
110

la

2 kg

Number of windings
Rated current IN1)

Number of windings
Rated current IN1)
4MA50 70-8AB00-0AN2

6
7

0.2
400

Secondary windings

lb

1.25
D

G H I
16 32

Z
500

4AM51 20-1DA00-0AN2
4AM51 20-2DA00-0AN2

10

Max. current, continuously A


Max. voltage
V

0.4

6.8

Max. current, continuously A


Max. voltage
V
Number of windings

6.8

6.8

0.8

1.6

0.4

0.8

1.6

3.2

26

3.2

6.4

26

12.5

not tted
K

0.85
200

3.6 kg

0.85
200

3.6 kg

G H
18

24

L M
36

N O
90

Max. current, continuously A


Max. voltage
V

4
1.2

4
2.4

4
3.6

4
7.2

4
9.6

4
14.4

2
36

Number of windings

N O
12

Z
500

11

4AM51 20-3DA00-0AN2

17.5
0.8

17.5
1.2

17.5
1.6

17.5
2.4

17.5
3.2

0.85
200
Y

3.6 kg

Z
500

12
13
14
15

4AM51 20-4DA00-0AN2

Max. current, continuously A


Max. voltage
V

17.5
0.4

7XR9 513

Isolating transformer for


differential protection with
1 pair of pilotwires

K1 M1 K1

7XR9 515

Isolating transformer for


differential protection with
1 pair of pilotwires

K2 M2 L2
T1 TO PILOT T2
1150
575

T3

7XR9 516

Isolating transformer for


communication converter

8
4.8

3.6 kg

Isolating transformer 1:1, max. 550 V


0.4 A continously, 3 A 10 s, 10 A 1 s
test voltage 20 kV, 50 Hz, 1 min

5 kg

Isolating transformer 1:1, max. 450 V


test voltage 5 kV, 50Hz, 1 min

2 kg

Isolating transformer 1:1,


max. test voltage 20 kV, 50 Hz, 1 min

1.4 kg

575

T4

P
m

m
S

1) Thermal withstand with simultaneous loading of all the windings: 1.2 x IN/continuously; 10 x IN/10 s; 25 IN/1 s.

13/8 Siemens SIP Edition No. 7

0.85
200

Accessories / 4AM and 7XR


4AM auxiliary current transformers, 7XR isolating transformers
Order No. and technical data

1
Kc Lc Kd Ld

kb lb

4AM49 30-6DB

4AM50 65-2CB

4AM49 30-7DB

4AM50 70-8AB

A B C D E F

4AM51 20-2DA

A B C D E F GH

SIPV6.027.eps

SIPV6.026.eps

J K L MNO Y Z

4AM51 20-1DA

A B C D E F GH

A B C D E F Y Z

G H J Y Z

SIPV6.025.eps

ka la

J K L MNO P Q

4AM51 20-3DA

4AM51 70-7AA

4AM51 20-4DA

4AM52 72-2AA

SIPV6.024.eps

Ka La Kb Lb

SIPV6.029.eps

G H J K L M Y

SIPV6.028.eps

A B C D E F Z

4AM52 72-3AA
Fig. 13/7

Connection of windings

7
8
9
10
11
12
13
14
15
Siemens SIP Edition No. 7 13/9

Você também pode gostar