Você está na página 1de 10

ENGLISH

Sentronik
SE 5000

ELECTRONIC CRANE SCALE

Using brochure

SENTRONIK - SCALEMARKET.COM

Suggestion: In order to keep your scale good condition, please do read the direction
book carefully and place it on hand for reference.

Catalogue
1. Special features
2. Exceptional functions
3. Primary technical characters
4. Basic operation
5. Guide of special display symbol
6. Simple problems and solutions
7. Dimensions and weight
8. Maintenance
9. Guide of setting parameters

1. Features
SE5000 electronic crane scale is a high accuracy, one-side direct display-measuring unit
that combines scale, load cell and power supply together. It can be directly hung on the
hook of a hoist and ensure the scale to complete the tasks of loading and weighing goods
synchronously. The screen is made up to super-bright digital tube (LED), which can be
easily seen over 25 meters. The scale body is made of strong alloy aluminum. Its
structure is compact and operation is quite easy.
This type of scale can be widely used in manufacturing, chemical engineering, steel or
fabric producing etc.. It is really a satisfying scale for modern management and high
production efficiency.
This type of scale can meet the standard of OIML and R76 due to it superior quality.
2. Exceptional functions
a.

Software calibrating
convenient, rapid trustworthy, cheat-preventing.

b. Voltage measuring
monitoring the battery voltage in scale conveniently.
c.

Auto power off


turning off automatically after 1.5 hours no working prevents battery from damaging by
operators negligence.

d. Taring automatically
ensuring the scale to work normal in any special environment.

3. Primary technical characters

(1). Basic parameters

Type

Maximum LOAD MINIMUM LOAD


(kg)
(kg)

DIVISION
(Kg)

NUMBER OF
DEVISION

SE5000-0.5

500

0.2

2500

SE5000-1

1000

10

0.5

2000

SE5000-2

2000

20

2000

SE5000-3

3000

20

3000

SE5000-5

5000

40

2500

SE5000-10

10000

100

2000

SE5000-15

15000

100

3000

SE5000-20

20000

200

10

2000

(2). Technical Characters


Accuracy classes

OIML

Taring range

100%F.S.

Result steady display

<10 seconds

Over weight range (alarm) 110%F.S.


Max safe load

125%F.S.

Limit coefficient

Power supply

12V/7Ah air tight rechargeable battery

Display tube

LED 30mm/5 per unit

Working temperature
range

-10~+40

Working humidity range

<90%RH at 20C

4. Basic operation
(1) Starting
Turn on the power switch on the rear panel of the scale. The screen will show 88888,
the buzzer sounds one time, then the screen shows the battery voltage in the scale. At
last, the screen shows 0, now it is ready for measuring. (After starting, it is warming up
3-5min.)
(2) Taring (Zero)
If scale shows the number is not 0, please press <zero> key.
(3) Measuring
Hang the object from the ground till it is motionless in the air. Then read the number
-3-

from the scales screen. If you want to get net weight of accessories such as rope etc.,
please press the <zero> key, 0 shown. Then hang the object; the screen will show the
net weight of the object. Microchip in the scale can store the value of accessories weight,
so every time you can get the net weight of the object till you changed the accessories
or turn off the machine.
(4) Battery checking
Start the scale, the screen will show 88888, the buzzer sounds one time, then the
screen shows the battery voltage UXX.XX automatically (above 12.00V normally), you
can check it and turn off the scale.
(5) Turning off
After using, turn off the power switch on the rear side of the scale, in prevent of
damaging to battery. If voltage is lower than 11.5V recharge it in time.
(6) Recharging
Turn off the switch on the rear side of the scale, insert chargers plug into the socket of
110V~. Then connect the charger and the scale with a lead. The indicating lamp on the
rear side of the panel will be on. The scale now is in the course of recharging.
5. Guide of special display symbol

Overweight symbol OE
If the weight on the scale exceeds the alarm lever, the screen will show OE and
overweight gross value XXXXX alternately.

Automatic prompt dLP


In the course of taring, it will show 0 after a second in normal condition. But if you
press <zero> key twice in a second, scale will be show dLP, then the scale go into
condition of automatic time-delay measuring the net weight. After 20 seconds, it can
tare the gross weight automatically; the screen will show 0. This function is special
suitable for extremely heavy object which is unable is to press zero key when measuring.

Warning symbol of reverse force to load cell Ad-


When a scale is put on the ground, the load cell undertakes the reverse force.
Sometimes the screen will show the symbol Ad-, but it will disappear when it is hung
in the air, it is a normal phenomenon unless the load cell leads are damaged or broken.
4

Low battery voltage ULbL


When the voltage in scale is lower than 11.5V, the screen will show ULbL, it suggests
low battery voltage in scale. Please recharge it in time.
6. Simple problems and solutions

Phenomena
No display after starting

Judgment

Solutions

Low battery voltage

Turing off the scale and


recharging

Broken battery

Replacing battery

Broken charger

Replacing charger

Battery cannot be charged Checking the power supply


Replacing battery
of charger
Checking the power supply
Re-plugging
Indicating lamp for
of charger
recharging is not working
No power in socket
Checking the power supply
No voltage battery

Turning off the object is


motionless

Motion of weighting object

Waiting till the object is


motionless

Unsteady display value

Insufficient warming time Warming up 3-5min


Display of empty scale not
Putting scale on ground for Improving the style of
equal to 0
excessive time
storage
7. Dimensions and Weight

Dimension (mm)

Capacity

Weight

1(0.5)

460

230

340

150

50

65

30

12

3(2)

550

230

340

150

60

80

40

17

690

230

340

150

100

120

50

25

(t)

(Kg)

-5-

10

820

230

340

150

100

120

55

34

15

980

230

340

150

120

130

60

68

20

980

230

340

150

120

130

60

68

8. Maintenance
Electronic crane scale is an exquisite measuring unit. Its power comes from storage
battery. Daily maintenance must be needed:

It should be warmed up 3-5 minutes after starting.

It should be avoided to be overweight in a long term. It can do great harm to the

load cell.
Recharge the battery after every using. If it is not used in a long time, recharge

it once a month.
If the scale is not needed, hang it or put it on a small vehicle. Do not let the hook

touch any object. The storage environment should be dry and clear.
Check small parts of the scale on time to ensure it in a good condition.

Guide of setting parameters


1.Keys Definition
Key

Functions

<S>

Enter or quit Parameter Setting Environment

<R>

Scale the zero point before working

<+>

Increase

<->

Decrease

<X>

Help of parameter searching or changing

<Y>

Change the parameter position that you want to modify

<X>, <R>

Ordinal press two keys check A/D code. Press <X>to return
working condition

<X>, <S>

Ordinal press two keys to check battery voltage. Press


<X>to return working condition

2.Parameters Definition
P00: password value: 34
P01: grade choice 12510 (setting by OIML )
P02: work pattern: 0:auto-save, 1:not save (default: 1)
6

P03: time allowed for reading value 3~15second(default: 5)


P04: automatic time-delay 1~99sec(default: 10)
P05: amplitude range 2~10d, 1%~10%F.S.; 1~9 corresponding to 2~10d, 11~19
corresponding to 1%~10%F.S. (default: 9)
P06: auto-save minimum weight 2~99d(default: 20)
P07: choice for turning off the scale. 00:manual, 11:time-delay auto off (1.5hour)
(default:00)
P08: position of decimal point 0,1,2,3,4
P09: scale point 0:no (auto zero tracking), 1:one point, 2:two point, 3:three point
P10: set maximum weight: allowed maximum weight
P11: alarm level: 110%F.S. maximum weight
P12: select weight M1: pre-known weight M1
P13: select weight M2: pre-known weight M2 (M2>M1)
P14: select weight M3: pre-known weight M3 (M3>M2)
P15: scaled coefficient 1:default
P16: scaled coefficient 2:default
P17: scaled coefficient 3:default
P18: turn point 1:default
P19: turn point 2:default
P20: turn point 3:default
3. Usage Method
Grade Changing: optional grade for selection: 1,2,5,10.
Press <Y>, <S> key at the same time, then loose <S>, then loose <Y>, the screen
will display p00
Press <X>, the password: 34 shown

-7-

Press <X> again, p01shown press <X>, current grade XX shown


Press <+>, modify the grade to you want, then press <X>, <S> at the same time;
the scale will be back to work condition. The scale now is working under the new
parameters.
Setting scale parameters:
Press <Y>, <S> key at the same time, then loose <S>, then loose <Y>, the screen will
display p00
Press <X>, the password:34 shown
Press <X>, p01shown, press <X> again, the screen will display p00...P20, then
you can modify any parameters that you want to modify (if from P06 to P07... you
should press <Y> and <X> at same time).
4. Example of setting parameters of 5t scale
Parameters setting

Functions

P08=0

Decimal point position is 0, no decimal

P09=3

Use 3 point scaling

P10=5000

Full scale is 5000Kg

P11=5500

Alarm level is 5500Kg

P12=1000

First scaled point is 1000Kg

P13=3000

Second scaled point is 3000Kg

P14=5000

Third scaled point is 5000Kg

Check all these choice and press <S>, quit the setting parameter environment
Hang the rope on the hook, press <zero> key of scale
According to order from minimum to maximum:

Hang the weight 1000kg till the object is motionless, press <Y>, then press <X>,

the screen will show bd1 in 10 sec, then the object weight on the screen will show 1000

Hang the weight 3000kg till the object is motionless, press <Y>, then press <+>,

the screen will show bd2 in 10 sec, then the object weight on the screen will show 3000

Hang the weight 5000kg till the object is motionless, press <Y>, then press <->,

the screen will show bd3 in 10 sec, then the object weight on the screen will show 5000
If the display number on the screen is equal to the weight, the scaling process is
completed. If not, it is repeat above the process.
8

According to the rule of measuring, re-check the accuracy of scale and other special
technical features
After completing the process, set P09=00 in order to forbid the scale go into scaling
condition by fault. (Warning: after showing P00, press <X>, then press <+> or <->.
Let the screen display a number not equal to 34, press <X>, <S> at the same time, then
you can lock all parameters.)

-9-

No need to praise quality


Focusing on improving

http://www.scalemarket.com

10

Você também pode gostar