DMR-800 - Installation and Hardware Guide

DMR-800D/L/
S-OEM/D-OEM
9 to 32 V DC

DMR-800D C1D2 with RS485 I/O


Module
9 to 32 V DC

I/O_02

Digital input: 0 Vbatt


low: 0 0.8 V
high: 2.5 V Vbatt
Digital output
open collector type
0 or HiZ
250 mA 11 sink current
Analog input: 10-bit A DC
Dynamic range: 0-2.8 V
Linear operation: 0.5-2.5 V
Resolution: 3 mV
Input clamped at 2.8 V
Accuracy: 1%
Same as I/O_01

I/O_03

Same as I/O_01

I/O_04

Same as I/O_01
plus
Analog current input (4-20 mA)

Digital input: 0 Vbatt


low: 0 0.8 V
high: 2.5 V Vbatt
Digital output
open collector type,
0 or HiZ
250 mA sink current
Analog input: 10-bit A DC
Dynamic range: 0-2.8 V
Linear operation: 0.5-2.5 V
Resolution: 3 mV
Input clamped at 2.8 V
Accuracy: 1%
RS485 + (A)
-9 to +13 V DC (relative to system
ground - Pin 4)
RS485 (B)
-9 to +13 V DC (relative to system
ground - Pin 4)
Same as I/O_01
plus
Analog current input (4-20 mA)

Power Supply
Voltage (Vbatt)
I/O_01

Note: If a digital input is left floating, reading a non-inverting digital input will
return logic high due to an internal weak pull-up (~100 kohm). For extremely
long wire, an external strong pull-up (1 kohm) may be required to compensate
for the voltage drop across the wire.
Note: Use an external pull-down if the digital input I/O line is configured to read a
switch to battery.
Note: Ensure the output impedance of the analog voltage source is <1 kohm
Note: The analog inputs are measured with respect to the terminal ground. Using a
short terminal power supply and ground wire connection is recommended as
any voltage drop on the ground reference affects the accuracy of the analog
input. The voltage drop is most pronounced during the transmission as the
current draw is largest at that time.

5.1.6

Serial Interfaces
Note: RS485 I/O module transceiver devices may go into thermal shut-down in the
event of a major short circuit condition. The transceiver device will re-enable
once the fault is cleared and the devices temperature drops by 15C.

11

Hardware version 21 has a maximum sink current of 50 mA [T9].

29

T10, Version 03

DMR-800 - Installation and Hardware Guide

Interface
RS232 Tx, Rx

RS485 I/O
module

5.1.7

DMR-800D/L/
S-OEM/D-OEM
Default: 9600 bit/s, 8 data, 1 stop, no
parity. Configurable up to 115,200
bit/s.
-

DMR-800D C1D2 with


RS485 I/O Module
Default: 9600 bit/s, 8 data, 1 stop, no
parity. Configurable up to 115,200 bit/s.
Default: 9600 bit/s, 8 data, 1 stop, no
parity. Configurable up to 115,200 bit/s.

DMR-800D/L/C1D2 Connector
DMR-800D/L/C1D2 terminals come with bottom or side mount 8-pin male
MINI-CON-X Conxall connectors.
Table 5

DRM-800D/L/C1D2 Connectors
7281-8PG-3ES
7282-8PG-3ES
6282-8SG-3DC

Side Mount
Bottom Mount
Mating Connector

5.1.7.1

DMR-800D/L Connector Pin-out


Table 6
Pin #
1
2
3
4
5
6
7
8

Connector Pin-out of DMR-800D/L


Functionality
I/O_01
RS232 Tx (output from terminal)
RS232 Rx (input to terminal)
Ground and shield
Power Supply Voltage (Vbatt)
I/O_02
I/O_03
I/O_04

Note: See notes in Section 5.1.5.


Figure 27 View of DMR-800D/L Terminal Male Connector (A) and
Rear View of Mating Connector (Solder Cups) (B)

1
2
3

7
8

4
(A)

7
8

6
5

4
(B)

30

T10, Version 03

DMR-800 - Installation and Hardware Guide

5.1.7.2

DMR-800D C1D2 Connector Pin-out


Table 7
Pin #
1
2
3
4
5
6
7
8

Connector Pin-out of DMR-800D C1D2 with RS485


Functionality
I/O_01
RS232 Tx (output)
RS232 Rx (input)
Ground and shield
Power Supply Voltage (Vbatt)
RS485 + (A) max. voltage range -9 to +13 V
RS485 (B) max. voltage range -9 to +13 V
I/O_04

Note: I/O_02 and I/O_03 are dedicated to RS485 and cannot be reconfigured as
general purpose I/Os.
Note: See notes in Section 5.1.5.
Figure 28 View of DMR-800D C1D2 Terminal Male Connector (A) and
Rear View of Mating Connector (Solder Cups)(B)

1
2
3

7
8

4
(A)

7
8

6
5

4
(B)

RS485 I/O Module Interface


x

DMR-800D C1D2 with RS485 I/O module supports the Modbus RTU protocol.

The RS485 I/O module supports a 2-wire twisted pair interface

The common ground wire is tied to all slave devices.

RS485 I/O module transceiver devices may go into thermal shut-down in the event of
a major short circuit condition. The transceiver device will re-enable once the fault is
cleared and the devices temperature drops by 15C.

RS232 Interface
x

On power-up, the state of the digital output is undefined until the terminal self-check
sequence is complete. If the DMR-800s transceiver chip has a disabled transmitter,
this will prevent the DMR from transmitting on the RS232 Tx user data port.

When a voltage greater than 0.5 V, for at least 0.1 second, is present on the RS232
Rx Data input port, this generates an external interrupt. Refer to [T8] for information
on power management modes.

31

T10, Version 03

DMR-800 - Installation and Hardware Guide

5.1.8

DMR-800D OEM/S OEM Connector


DMR-800D OEM/S OEM terminals come with horizontal or vertical 10-pin female
header.
Part number
5-103634-9
5-103639-9
5-103956-9
M20-9991046 (un-shrouded)

Horizontal Header
Vertical Header
Mating Header

5.1.8.1

Manufacturer
Amp
Amp
Amp
Harwin

DMR-800 OEM Connector Pin-out

CAUTION

Connector pin-outs differ between the DMR-800 OEM and the


DMR-200 OEM.
Table 8

Connector Pin-out of the DMR-800 OEM

Pin #
1
2
3
4
5
6
7
8
9
10

Functionality
NC
NC
RS232 Rx (input)
RS232 Tx (input)
I/O_01
I/O_02
I/O_03
I/O_04
Power Supply Voltage Vbatt
Ground and shield
Pin 1 Indicator

10

5.2

Satellite Interface
Frequency Range
Antenna G/T (at zenith)
Max EIRP (return link)

Rx: 1525.0 to 1559.0 MHz


Tx: 1626.5 to 1660.5 MHz
-25 dB/K
9 dBW

32