Escolar Documentos
Profissional Documentos
Cultura Documentos
030
FM2789
0814
Supersedes
0214
WASTE-MATE SERIES
MATERIALS
PUMP
MOTOR
PRODUCT SPECIFICATIONS
Horse Power
1/2
Voltage
115 - 460
Phase
1 or 3 Ph
Hertz
60 Hz
RPM
1725
Type
Split phase or 3 Ph
Insulation
Class A or B
Amps
1.5 - 10.4
Operation
Automatic or nonautomatic
Discharge Size
Solids Handling
Cord Length
Cord Type
Max. Head
21.5' (6.6 m)
130 F (54 C)
Cooling
Oil filled
Motor Protection
Cap
Cast iron
Motor Housing
Cast iron
Pump Housing
Cast iron
Base
Upper Bearing
Sleeve bearing
Lower Bearing
Sleeve bearing
Mechanical Seals
Impeller Type
Non-clogging vortex
Impeller
Hardware
Stainless steel
Motor Shaft
Gasket
Neoprene
B
C
SK375
MODEL DIMENSIONS
MODEL
266
4 3/4" [12.1cm]
8 5/16" [21.1cm]
6 13/32" [16.3cm]
4 3/4" [12.1cm]
6 15/32" [16.4cm]
2" NPT
14 1/32" [35.6cm]
6 3/32" [15.5cm]
267
4 3/4" [12.1cm]
8 5/16" [21.1cm]
6 13/32" [16.3cm]
4 3/4" [12.1cm]
6 15/32" [16.4cm]
2" NPT
14 5/8" [37.2cm]
6 3/4" [17.1cm]
268
4 3/4" [12.1cm]
8 13/32" [21.4cm]
6 13/32" [16.3cm]
4 3/4" [12.1cm]
6 15/32" [16.4cm]
2"/3" NPT
14 5/8" [37.2cm]
9 1/16" [23.0cm]
UL
FEET
METERS
SELECTION GUIDE
20
15
4
10
2
5
Tank Diameter
18 Simplex
CAUTION
Model
20
GALLONS
LITERS
Volume Pumped
80
40
15 Gal (56.8 L)
30 Duplex
22 Gal (83.3 L)
36 Duplex
33 Gal (124.9 L)
48 Duplex
60 Gal (227.1 L)
80
MODEL
8 Gal (30.2 L)
24 Simplex
60
Feet
5
10
15
20
100
120
400
013225
266/267/268
Meters
1.5
3.0
4.6
6.1
Gal.
128
89
50
10
Shut-off Head:
MODEL COMPARISON
140
Liters
484
337
189
38
21.5 ft.(6.6m)
CERTIFICATIONS
Seal
Mode
Volts
Ph
Amps
HP
Hz
Lbs
Kg
Simplex
Duplex
cCSAus
UL
M266/BN266
Single
Auto
115
10.4
1/2
60
41.0
19
N266
Single
Non
115
10.4
1/2
60
41.0
19
2 or 3
2 or 4
D266/BE266
Single
Auto
230
5.5
1/2
60
41.0
19
---
E266
Single
Non
230
5.5
1/2
60
41.0
19
2 or 3
H266
Single
Auto
200-208
6.2
1/2
60
41.0
19
---
I266
Single
Non
200-208
6.2
1/2
60
41.0
19
J266
Single
Non
200-208
2.6
1/2
60
41.0
19
F266
Single
Non
230
2.6
1/2
60
40.0
18
G266
Single
Non
460
1.5
1/2
60
40.0
18
M267/BN267
Single
Auto
115
10.4
1/2
60
47.5
22
N267
Single
Non
115
10.4
1/2
60
47.5
22
2 or 3
D267/BE267
Single
Auto
230
5.5
1/2
60
47.5
22
---
E267
Single
Non
230
5.5
1/2
60
47.5
22
2 or 3
H267
Single
Auto
200-208
6.2
1/2
60
47.5
22
---
I267
Single
Non
200-208
6.2
1/2
60
47.5
22
J267
Single
Non
200-208
2.6
1/2
60
47.5
22
F267
Single
Non
230
2.6
1/2
60
47.5
22
G267
Single
Non
460
1.5
1/2
60
47.5
22
M268/BN268
Single
Auto
115
10.4
1/2
60
51.0
23
N268
Single
Non
115
10.4
1/2
60
51.0
23
2 or 3
D268/BE268
Single
Auto
230
5.5
1/2
60
51.0
23
E268
Single
Non
230
5.5
1/2
60
51.0
23
2 or 3
H268
Single
Auto
200-208
6.2
1/2
60
51.0
23
---
I268
Single
Non
200-208
6.2
1/2
60
51.0
23
J268
Single
Non
200-208
2.6
1/2
60
51.0
23
F268
Single
Non
230
2.6
1/2
60
51.0
23
G268
Single
Non
460
1.5
1/2
60
51.0
23
CAUTION
All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed
including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).