SeismicQualificationofNPPStructures,
SystemsandEquipmentComponents
MarekTengler
SeismicEngineeringKnowledgeTransferSeminar
NuclearResearchInstitutein e,November2125,2011
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
TOPICS
OverviewofExistingStandards
PrinciplesofEquipmentSeismicQualification(SQ)
AnalysisMethods
ExperimentalMethods
MethodologyofSQincludingGIPandPracticalExamples
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
2/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
1.OVERVIEWOFEXISTINGSTANDARDS
National
Nuclear Law,
Convention on Nuclear
Safety
HierarchyofLegislation,Codes,NormsandStandardsRelatedtoSeismicQualification
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
3/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.OVERVIEWOFEXISTINGSTANDARDS (Contd)
~4500OtherStandardsCitedinRegulatoryDocuments
Reference:NUREG/CR5973,PNL8462Rev.3,CodesandStandardsandOtherGuidanceCitedinRegulatory
Documents,PublishedAugust1996.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
4/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
5/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.SEISMICQUALIFICATION
MOTHERHOOD STD.
IEC 980:1989
ASME QME-1-2007
Consequentialapplicablestandardsofseismicqualification:
Partialstandardsoftribalstandards:IECseries600682,600683
(standardsformechanicalandvibrationresistance)
Specificstandards:IEC255213,C37.981987,IEEEStd3822006,
IEEEStd3171983etc.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
6/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.SEISMICQUALIFICATION INTRODUCTION
WithintheseismicsectionoftheEQprogram,allsafetyrelated
equipmentmustproveitsseismicadequacytowithstandtheeffectsof
theearthquakecorrespondingtothemaximumdesignearthquake(SSE,
S2,SL2).Onepartoftheseismicadequacyverificationisthe
demonstrationtheequipmentiscapabletowithstandthecumulative
degradationeffectoffiveprojectdesignearthquakes(OBE,S1,SL1),
whichmustnotaffecttheresistanceoftheequipmenttotheimpactof
themaximumdesignearthquake(SSE,S2,SL2).
Theseismicqualificationmustassuretheequipmentwillholdits
capabilitytoperformtherequiredsafetyfunctionsduringand/oraftera
seismiceventkeepingsuchastatethatcorrespondstotheendofits
qualifiedlife.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
7/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.SEISMICQUALIFICATION SEISMICCLASIFICATION
TheequipmentofanNPPsafetysystemsisgroupedintoseismicclasses (sub
classes)accordingtothefollowingdefinitions(Generaldefinition):
1(A)fullfunctionalityisrequireduptoandincludingthemaximumdesign
earthquakelevel(SSE,S2,SL2).
1(B)onlymechanicalintegrityisrequired(i.e.strengthandleaktightness)in
accordancewithrelevantstrengthstandardsandregulations;partialfailuresof
thefunctionalityareadmitteduptoandincludingthemaximumdesign
earthquakelevel(SSE,S2,SL2).
1(C)onlystabilityisrequired,i.e.toavoidseismicinteractionswithotherSSC
(tokeepthestablepositionmostly);partialfailuresofthefunctionalityaswell
asthemechanicalintegrityareadmitteduptoandincludingthemaximum
designearthquakelevel(SSE,S2,SL2).
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
8/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.SEISMICQUALIFICATION SEISMICINPUT
Seismicconditions ofthebuildings arerepresentedbyrequiredresponse
spectra(RRS)ofthelocations,onwhichtheequipmentsubjecttoqualification
isinstalled.
FiguresonnextpageshowanexampleoftheRRS(smoothed)formaximum
designearthquake(SSE,S2,SL2).
ThesmoothingofcalculatedRRScanbedoneusingthemethoddescribedinUS
NRCRG1.122.
Thespectrashallcorrespondtothesignificantplaces(floororstructures)
situatedinsidetheseismicclassifiedcivilstructures(buildings)whereclassified
equipmenttobeinstalled.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
9/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.SEISMICQUALIFICATION SEISMICINPUT(Contd)
RRSenvelope,horizontaldirection.Earthquake RRSenvelope,verticaldirection.Earthquake
levelSSE,S2,SL2
levelSSE,S2,SL2.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
10/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.SEISMICQUALIFICATION SEISMICINPUT(Contd)
Theaccelerationsneededtodeterminetheseismicexcitationwiththeintensityofthe
projectdesignearthquake(OBE,S1,SL1)arederivedfromtheshownRRSofmaximum
designearthquakeastheonehalfoftheaccelerationRRSSSE(S2,SL2)forthespecified
frequency.
Fortheequipmentwhichisconnectedwithapipelinesysteminaverygoodmanner,
liketemperaturesensors,valveactuatorsetc.,andwhichrequirethedemonstrationof
theirfunctionality,aspecifictechniqueoftheseismicqualificationneedstobeapplied.
Suchequipmentactsasthepipelinecomponentsandtheyaresubjectedtoveryhard
seismicloads.Theseloadsaregeneratedintheplaceoftheequipmentastheseismic
responseofthepipelinesystem.Amplifiedexcitationforcesareofthediscretenature
withasingledominantfrequency.Toqualifytheequipmentconnectedwithpipeline
systemstheseismicexcitationderivedfromtheRIMcurvemustbeadditionallyapplied
togenericseismicqualificationRRStests.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
11/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.SEISMICQUALIFICATION SEISMICINPUT(Contd)
RequiredInputMotion(RIM)curve(seeIEEEStd382).LevelSSE,S2,SL2.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
12/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
2.SEISMICQUALIFICATION METHODS
Todemonstratetheseismicadequacyofseismiccategory1structures,systems
andequipmentcomponentsthefollowingmethodsareused:
(a)seismicanalyses(mainpipelines,mainmechanicalcomponents,
anchorageofequipment),
(b) seismictests(activemechanicalcomponents,electricalandI&C
components),
(c)earthquakeexperienceandindirectprocedures(smallborepipes,HVAC
ducts,additionalapproachtoverifyseismicadequacyofequipment
componentsasmountedusingtheGIPVVERprocedure).
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
13/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
4.QUALIFICATIONBYSEISMICANALYSIS
Purpose:Tedeterminedcriticalresponseparametersofequipmenttobe
evaluatedforoperationalandseismicloadsbycalculation.
Generalmethodsofresponsecalculation:
Handcalculus(simplyequation);
FiniteElementMethod;
Combinationofbothabovementioned.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
14/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
4.QUALIFICATIONBYSEISMICANALYSIS(Contd)
Methodsofthecalculationofseismicresponse
- Staticanalysisforstiffcomponentswithnaturalfrequencyabove33Hz;
Equivalentstaticanalysisforsimplycomponents
Responsespectramethodcomplexcomponentslineardynamicbehavior
assumed
Timehistorymethodcomplexcomponentslinearandnonlineardynamic
behaviorassumed
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
15/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
4.QUALIFICATIONBYSEISMICANALYSIS(Contd)
Assessmentofbaseparametersofcomponentcapacity
- Integrityofpressureboundary(housing,nozzles);
Capacityofinternals;
Supports(supportingstructure)capacity;
Anchor/fixtureresistance.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
16/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
4.QUALIFICATIONBYSEISMICANALYSIS(Contd)
Assessmentofperformancecapabilityofcomponent
Inaddition,fordocumentationofperformancecapability(functionality)of
activemechanicalcomponentsareevaluatedparametersthataffectingtheir
performanceofdemandedsafetyfunction:
- Totalrelativedisplacementsofmovingandstaticpartstoassesstheir
collisionsduringinducedseismicmotionsdepletionofdesignspacings
betweenparts.
Totalreactionforcesandoveralldisplacementsinpointofpartsplacing
jamingofbearings.
Totaldeformationinplacesofacontactofsealingareasviolationof
pressuretightness.
- Otherspecificparametersrelatingtoevaluatedcomponent.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
17/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
4.QUALIFICATIONBYSEISMICANALYSIS EXAMPLE
MathFEmodeloftheflapvalveDN1000
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
18/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
4.QUALIFICATIONBYSEISMICANALYSIS EXAMPLE(Contd)
SeismicexcitationRIMaccordinglyIEEEStd3822006
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
19/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
4.QUALIFICATIONBYSEISMICANALYSIS EXAMPLE(Contd)
MaximumresultingdistributionoftotaldisplacementsatexcitationinZ
direction,max.11.4mm
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
20/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
4.QUALIFICATIONBYSEISMICANALYSIS EXAMPLE(Contd)
Disc of flap
Loading
Max. displ. X
[mm]
Max. displ. Y
[mm]
Max. displ. Z
[mm]
Max. displ
[mm]
NOC
0,0
0,0
0,3
0,3
SSE X
1,5
2,0
1,5
2,6
SSE Y
4,7
5,6
2,9
5,7
SSE Z
1,1
1,6
11,3
11,4
Max. total
displacement
[mm]
Allowable
displacement
[mm]
11,5
20,0
Fy
[kN]
Fz
[kN]
Stress
[MPa]
NOC
1,43
3,83
1,29
SSE X
5,00
1,07
1,62
SSE Y
12,25
1,24
3,90
SSE Z
3,30
11,42
3,77
Max. stress
[MPa]
Allowable stress
[MPa]
5,19
30,0
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
21/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
5.QUALIFICATIONBYSEISMICTEST GENERALLY
TheseismictestsofequipmentinNPPsaregenerallypreferredmethodsforthe
qualificationprogramof
Activetechnologicalequipment(e.g.valvesandtheiractuators)
Electricalequipment(e.g.switchgears)
I&Cequipment(cabinetsandpanels)
Sensitiveequipmentcomponentslikerelays,contactors,circuitbreakers,
transmitters,sensorsetc.
Theseismiccapacityofsuchequipmentinregardoftheirfunctionalityduringandafter
anearthquakeisimpossible,difficultorunreliabletoevaluatebyothermethods.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
22/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
5.QUALIFICATIONBYSEISMICTEST DIVISION
SEISMICINPUTMOTION
Singlefrequencymotion(withassumptiontheequipmentwillbesubjectedtosteady
vibrationswithonedominantfrequency,seeRIM,or,iftheexaminationofthe
naturalfrequenciesandthedampingvaluesoftheequipmentisperformed);
Multifrequencymotion(generallypreferredfortheverificationoftheseismic
capabilityoftheequipment,themotionsimulationisveryclosetothetypical
earthquakemotion).Inmultifrequencyseismictestingtwoapproachesareapplied:
o Testwithrandomexcitation(inputseismicmotionappliedonthetestpieceis
givenbysynthetictimehistory;TRScorrespondstorealquakemotion);
o Testwithcomplexsineexcitation(inputseismicmotionappliedonthetest
pieceisgivenbythesuperpositionofcomplexsinewaves)
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
23/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
5.EXPERIMENTALMETHODS EXCITATIONDIRECTIONS
TESTSAMPLEORIENTATION
Singleaxistests(seismicinputmotionisappliedonlyinonedirection);
Biaxialtests(seismicinputmotionisappliedintwodirections)
o Biaxialinstallationtestingfortwoindependentdirections(seismicinputmotionfor
eachdirectionisstatisticallyindependent);
o Singleaxisinstallationtestsfortwodependentdirections(seismicplatformmoveson
inclinedplane);
Triaxialtests(seismicinputmotionappliedinthreedirections/axesofatestpiece
simultaneously).
o Triaxialinstallationtestperformedwithsimultaneousbutindependentinputwaveform
intothethreepreferredaxesofthespecimen;
o Biaxialinstallation(vertical/horizontal)testswithindependentsimultaneousexcitation
signalsinhorizontalandverticalplane.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
24/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
5.EXPERIMENTALMETHODS RRS
RequiredResponseSpectrum(RRS)istheresponsespectrumissuedbytheuserofthequalified
equipmentorbytheusersagentaspartofthespecificationforqualification.RRSrepresentsa
requirementtobemet.Theyarepreparedforallthreeorthogonalspacedirectionsoratleastfor
horizontalandverticaldirections.
RequiredResponseSpectrapreparation
Createdtocoverapplicationforwholebuilding/wholeplant;
EnvelopeofbroadenedandsmoothedFRSforequipmentinstallationlocation(equipment
anchoredtotherelevantfloor/structure);
MultipleofbroadenedandsmoothedFRSduetoexcitationappliedonlyinonedirection(factor
1.5);
MultipleofbroadenedandsmoothedFRSduetoequipmentinstallationonotherstructuresor
equipment(usingamplificationfactor);
Combinationofpreviousboth.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
25/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
5.EXPERIMENTALMETHODS RRSVS.TRS
TestResponseSpectra(TRS)arecalculatedfromtherecordingsoftheactualmotionofthe
shakingtable.TRSshallenveloptheRRSortheapplicableportionoftheRRStakingintoaccount
thedynamiccharacteristicsoftheequipmenttested(naturalfrequency).TRSshallbecomputed
with1/3octave(ornarrower)bandwidthresolution.
TRSandRRScomparisonismadefororallthreeorthogonalspacedirectionsoratleastfor
horizontalandverticaldirectionsandforfiveOBE(S1,SL1)earthquakesfollowedbyoneSSE(S2,
SL2)earthquakes.Howeverinsteadof5OBE(S1,SL1)earthquakesthespecimenmaybe
subjectedto2testscorrespondingtolevelSSE(S2,SL2).
TRSandRRSarecomparedwhichhavethesamedampingvalue.Recommendeddampingvalueis
5%damping.ItisacceptabletocompareRRSwithTRSofhigherdampingvaluethenisthe
dampingvalueofRRS,nevertheless,TRSmustenvelopRRS.
Iftheresonancephenomenadoesnotexistbelow5Hz,theRRSshouldbeenvelopedfor
frequencyvaluesabove3.5Hz.Bandwidth13.5Hz,howevershouldbecovereduptolevel
providedbytestingdevice.Ifresonancephenomenaexistbelow5Hz,TRSshallenvelopRRSfrom
1Hz.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
26/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
5.EXPERIMENTALMETHODS RRSVS.TRS(Contd)
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
27/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
28/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.QUALIFICATIONBYEXPERIENCE/INDIRECTMETHOD
In1982havebeenestablishedSeismicQualificationUtilityGroup,wita
purposedofcoordinatingandfoundingworksondevelopmentofstudy
aboutbehaviorofmechanicalandelectricalcomponentsincaseof
destructiveearthquakes.
Firstphaseofthoseworksfinishedalreadyin1978,whenhavebeen
publishedreportdefined20equipmentclassesindentifiedasinevitable
forsafeshutdownofnuclearunits.
Thereportevaluatedfeaturesofdifferentequipmentclassesduring
severeearthquakeandfoundedcriteriaofseismiccapacity,i.e.caveats,
thathavebeendevelopedforeachequipmentclass.
Ithasbeenalsodeterminedthecapacityspectrumofequipment,so
called,BoundingSpectrum,BS.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
29/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.QUALIFICATIONBYEXPERIENCE/INDIRECTMETHOD
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
30/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.QUALIFICATIONBYEXPERIENCEGIP
Thescopeofequipmentcoveredbythe currentversionoftheGIP procedureincludes, the
followingtwentyclassesofmechanicalandelectricalequipment:
(1)MotorControlCenters;
(11)Chillers;
(2)LowVoltageSwitchgears;
(12)AirCompressors;
(3)MediumVoltageSwitchgears;
(13)MotorGenerators;
(4)Transformers;
(14)EngineGenerators;
(5)HorizontalPumps;
(15)DistributionPanels;
(6)VerticalPumps;
(16)BatteriesonRacks;
(7)FluidOperatedValves;
(17)BatteryChargersand
Inverters;
(8)MotorOperatedandSolenoid
OperatedValves;
(18)InstrumentsonRacks;
(9)Fans(ventilators);
(19)TemperatureSensors;
(10)AirHandlers;
(20)I&CPanelsandCabinets.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
31/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
32/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE WALKDOWNPROCEDURE
TheGIPaswellastheGIPVVERortheDOEGIPisprimarilyascreeningandwalkdown
procedure.However,ifanequipmentitemisclassifiedasanoutlier,rigorous
approachesastestingonshakingtable,deepstudyofinputdata,sophisticatedanalysis
etc.maybeusedtoverifyitsseismicadequacy.Generally,fourmajorstepsofthis
procedurewhenappliedevaluationofseismicadequacyofclassesofequipment
identifiedaboveareasfollows:
selectionofSeismicReviewTeam(SRT);
identificationofequipmenttheseismicadequacyshallbeevaluatedandsetupthe
SeismicEquipmentList(SEL);
screeningverificationandwalkdowns;
outlieridentificationandresolution.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
33/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE WALKDOWNPROCEDURE(Contd)
AnengineeringjudgmentisthemajortoolusedbySRTduringthescreeningverification
andwalkdownstoevaluateseismicadequacyoftheequipment.TheSRTshouldinclude
thesystemengineers,plantoperationpersonnel,experiencedandprofessionally
trainedseismiccapacityengineers,andalsopersonneltoidentifyandevaluate
essentialrelays(ifnecessary).
Seismicevaluationengineersshouldhaveatleast3yearsexperienceinseismicdesign
orqualificationofnuclearsafetyrelatedstructures,systemsandcomponents.They
shouldhaveatleastabachelorsdegreeincivilormechanicalengineeringandformal
instructioninstructuraldynamicanalysis.Theyshouldalsohavecompletedatleasta3
daycourseincludingfieldanalysisintheuseofGIPVVERmethodologyinseismic
evaluationofnuclearfacilitysafetyrelatedSSCs.ItisforbiddentousetheGIPVVER
procedurewithoutdeepstudyofcorrespondingdocumentation,trainingandpractical
experience.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
34/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE CRITERIA
Thebasiccriteriatoverifyseismicadequacyofanequipmentitemduringthescreeningwalkdown
are(seealsoschema&flow):
seismiccapacitygreaterthanseismicdemand(bycomparisonofthecorresponding
ISRSRLE(SL2,SSE)orGRSRLE(SL2,SSE)totheBoundingSpectrum;
similaritytotheequipmentintheseismicexperiencedatabases(checkingofcaveats,based
onwalkdownandinformationavailablefromdocumentation);
adequateanchorageofequipment (calculationsorengineeringjudgment,basedonwalkdowns
andinformationavailablefromdocumentation);
potentialseismicinteractionsevaluated(basedonwalkdowns).
TheGIPVVERprocedureusestwoboundingspectra(BS):
(a) BSattachedtoPGA=0.33g(thesameasintroducedbySSRAPandusedbyGIP);
(b) BSattachedtoPGA=0.50g(1.5timesSSRAPBS)forselectedVVERequipmentclasses,which
areevidentlyrobustandrugged.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
35/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE SCHEMA&FLOW
START
NO
YES
CAPACITY/DEMAND OUTLIER
NO
ARE CAVEATS MET?
YES
CAVEAT OUTLIER
NO
IS ANCHORAGE ADEQUATE?
DETAIL INVESTIGATION
YES
ANCHORAGE OUTLIER
ARE INTERACTIONS
ACCEPTABLE?
NO
DETAIL INVESTIGATION
YES
INTERACTION OUTLIER
NO
YES
VERIFIED
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
36/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE CAPACITYSPECTRA
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
37/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE CAPACITYVS.DEMAND
A.ComparisonwithRLE(SL2,SSE)GroundResponseSpectra(GRS)2)
Thiscanbeusedwhentheequipmentitemismountedbelowabout12mabovethe
effectivegradeandwhenthenaturalfrequencyofequipmentisgreaterthan12Hz3)
BSGRSRLE(SL2,SSE)(5%damping)4)
B.ComparisonwithRLE(SL2,SSE)InStructureResponseSpectra(ISRS)
1.5xBSrealistic(median,mean,bestestimated)ISRSRLE(SL2,SSE)(5%damping)4)
Notes:
(1)Applyatleastoneofthesetworules,whichapplicable.
(2)ThecriterionAcanbeusedonlywiththewellrigidbuildingstructuresasthelowerconcrete
reactorbuilding.Donotusethiscriterionwithevidentlyflexiblebuildingstructures.
(3)Donotapplythe12Hzlimitforequipmentmountedonpipingsystems(valves,valveoperators
etc.).
(4)Thesecriteriashallbemetforallthreeorthogonalspatialdirections.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
38/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE SIMILARITY
SimilarityofVVERtypeequipmenttoequipmentincludedinthedatabases ofseismicresistant
equipmentisthemostimportantkeystoneofpracticalapplicationoftheGIPVVERprocedure.
Generally,theprincipalofsimilarityisbaseduponcomparisonofequipmentdynamicandphysical
characteristics.Theproceduretoestablishsimilaritywithinaneachequipmentclassincludesthe
followingcomparisons:
mostprobablemodesofmalfunction(basedonrecognizedbehaviorofallcriticaldevices);
predominantresonantandcriticalfrequenciesandmodeshapes;
criticaldamping;
mostimportantphysicalequipmentcharacteristics,like
equipmentsize,massandposition(vertical,horizontal,inclinedetc.);generalmaking,qualityof
making,ageofequipment;locationofthecenterofgravity,presenceandlocationof
cantileveredparts;implementationofheavyand/ormovinginternalparts;implementationof
supportsandanchorage;implementationofattachedlines,substructures,devicesetc.;
presenceofdevices(mechanicalorelectrical)sensitivetovibrationsandshocks.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
39/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE ANCHORAGE
Thescreeningapproachtoverifyofequipmentanchorageisbaseduponacombinationof
inspections,calculations,andengineeringjudgment.
Inspectionsconsistofmeasurementsandvisualevaluationsoftheequipmentanditsanchorage,
supplementedbyuseofplantdocumentationanddrawings.Calculationsshouldbeperformedto
comparetheanchoragecapacitytothecorrespondingloading(demand)imposeduponthe
anchorage.Engineeringjudgmentisalsoanimportantpartintheevaluationofequipment
anchorage.
Generally,evaluationtheadequacyofequipmentanchorageincludes:
anchorageinstallationinspection,
anchoragecapacitydetermination,
anchoragedemanddetermination,
comparisonofcapacitytodemand.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
40/41
remsed00711.ujv.rev0
STEVENSON AND ASSOCIATES Office in Czech Republic a. s., Vejprnicka 56, CZ 318 00 Pilsen, Czech Republic
www.stevenson.cz
6.GIPVVERPROCEDURE SEISMICINTERACTIONS
Thefourseismicinteractioneffectsthatareconsideredare:
proximity(impactsofadjacentequipmentorstructuresonsafetyrelatedequipment
duetotheirrelativemotionduringanearthquake),
structuralfailureandfallingofoverheadoradjacentstructures,systems,or
equipmentcomponents),
flexibilityofattachedlinesandcables,
floodingduetoearthquakeinducedfailuresoftanksorvessels.
SeismicQualificationofNPPStructures,SystemsandEquipmentComponents
41/41
remsed00711.ujv.rev0