TECHNICAL DATA BY THE TENDERER

TRANSFORMERS

Unit auxiliary transformer


Number of transformers
Manufacturer
3-phase and oil transformer
Type of cooling

yes/no

Rated power (cont. duty) ONAN / ONAF1 / ONAF2


Rated frequency
Voltages at no load and on-load tap changer in nominal position
H.V./L.V, side
Vector group and numerical index
Impedance voltage (tap changer in nominal position) HV-LV1
HV-LV2
LV1-LV2
Max. noise level at a distance of 0.3 m according to IEC 551
Impulse withstand voltage H.Y. side
Power frequency withstand voltage H.V. side
Impulse withstand voltage L.V. side
Power frequency withstand voltage L.V. side
On load tap changer:
- Number of steps
- Voltage range total
Current transformers on the H.V. bushings
- Rated output
- Accuracy class
- Number of cores
- Ratio

Current transformers on L.V. side bushings


- Rated output
- Accuracy class
- Number of cores
- Ratio

Current transformers on star point (LVN side)


- Rated output
- Accuracy class
- Number of cores
- Ratio
Connection on H.V, side
Connection on L.V, side

TENDERER

UNIT

DATA

-----

%
%
%
dB (A)
kV (peak)
kV
kV (peak)
kV

2
HYUNDAI
Yes
ONAN/ONAF1/
ONAF2
30/40/54
(15/20/27:15/20/27)
50
18 / 6.9 / 6.9
H.V
Dyn11yn11
12.5% @ 27MVA
12.5% @ 27MVA
25% @ 27MVA
76
125
50
75
28

8
1.25*8

VA
--

50 / 50 / 50 / 15
5P20/ CL0.5/CL0.2 /
CL3.0
3 / 1 / 1 / 1(H2)
4000-3000/5A
4000-3000/5A
4000-3000/5A
2500/2A (For WTI)

MVA
Hz
kV

---

VA
----

VA
-----

(L.V1 / L.V2)
15
CL3.0
X2 : 1ea, X3 : 1ea
Y2 : 1ea, Y3 : 1ea
X2 & Y2 : 3000/2A
(For WTI)
X3 & Y3 : 2500/5A
(For AVR)
(L.V1N / L.V2N)
50
5P20
X0 : 2ea, Y0 : 2ea
1200/5A
Delta
Star

TECHNICAL DATA BY THE TENDERER

TENDERER

UNIT

DATA

--

Resistance grounded
(1000A)

Loss
No load losses at rated frequency ;
- at 100% rated voltage
- at 105% rated voltage
- at 110% rated voltage

kW
kW
kW

35
42
51

Load loss at central tap;


- at 100% of Max. MVA load

Kw

305

TRANSFORMERS

Unit auxiliary transformer (continued)


Treatment of neutral (star point) of L.V. windings

Auxiliary power requirements of any cooling equipments and


others, kW
Main dimensions:
Length x width x height
Gross weight
Transport weight
Oil weight

kW

mm
t
t
t

Applicable Codes and Standards


Tests to be applied

KKS No.

8090x6108x4838
96.1
65
19.8
IEC 60076
Routine test as per
IEC 60076
Type test as per IEC
60076

--

14BBT01 (Unit 1)
14BBT02 (Unit 2)

TECHNICAL DATA BY THE TENDERER

TENDERER

UNIT

DATA

Automatic voltage regulator


Number of AVR
Relay type

---

1
TAPCON 230

Rating of voltage transformer

Rating of current transformer

Rated frequency
Sensitivity (of transformer voltage)

Hz
%

TRANSFORMERS

Response time (referred to 1'/. deviation from derived value)

min.

Range of set point adjustment


Current responsive raising of set point
Limitation of current effect
Over voltage Umax.
Under voltage Umin.
Over current Imax.
Auxiliary voltage AC/DC

% Un
% Un
% Un
% Un
% Un
% In
V

Voltage drop compensation


Special requirement:
Suitable for mounting in air-conditioned
Switchgear room

I Un

TR rated volt /
(85~140V)
Tr rated current /
0.2/1/5A
40~60
Measuring error
<0.3%
Delay time T1 :
0~180S, Linear or
inverse response
selectable.
Later
Later
Later
101 ~ 130
70 ~ 99
50 ~ 210
115Vac
(+25% - 35%)
0~15%

yes/no

Yes
Yes

Applicable Codes and Standards


Tests to be applied

IEC, EN, VDE


As per IEC, EN,
VDE