This Home Inspection is exclusively prepared for:

Todd Rossi
By
Glenn Wharton
TREC 3772
Texas Inspection Partners
330 Rayford Road, Ste 187, Spring, TX 77386
Phone: (936)228-0258 Fax: (866)734-4310 Email: glenn.wharton@att.net

PROPERTY INSPECTION REPORT


Report #: GW20100211-02

Prepared For: Todd Rossi


(Name of Client)

Concerning: 4610 Nina Lee, Houston, TX 77092


(Address of Inspected Property)

By: Glenn Wharton, #TREC 3772 02/11/2010


(Name and License Number of Inspector) (Date)

This property inspection report may include an inspection agreement (contract), addenda, and other
information related to property conditions. If any item or comment is unclear, you should ask the inspector
to clarify the findings. It is important that you carefully read ALL of this information.
This inspection is subject to the rules ("Rules") of the Texas Real Estate Commission ("TREC"), which
can be found at www.trec.state.tx.us.
The TREC Standards of Practice (Sections 535.227-535.231 of the Rules) are the minimum standards for
inspections by TREC-licensed inspectors. An inspection addresses only those components and conditions
that are present, visible, and accessible at the time of the inspection. While there may be other parts,
components or systems present, only those items specifically noted as being inspected were inspected.
The inspector is not required to move furnishings or stored items. The inspection report may address
issues that are code-based or may refer to a particular code; however, this is NOT a code compliance
inspection and does NOT verify compliance with manufacturer's installation instructions. The inspection
does NOT imply insurability or warrantability of the structure or its components. Although some safety
issues may be addressed in this report, this inspection is NOT a safety/code inspection, and the inspector
is NOT required to identify all potential hazards.
In this report, the inspector will note which systems and components were Inspected (I), Not Inspected
(NI), Not Present (NP), and/or Deficient (D). General deficiencies include inoperability, material distress,
water penetration, damage, deterioration, missing parts, and unsuitable installation. Comments may be
provided by the inspector whether or not an item is deemed deficient. The inspector is not required to
prioritize or emphasize the importance of one deficiency over another.
Some items reported as Deficient may be considered life-safety upgrades to the property. For more
information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards, form OP-I.
This property inspection is not an exhaustive inspection of the structure, systems, or components. The
inspection may not reveal all deficiencies. A real estate inspection helps to reduce some of the risk
involved in purchasing a home, but it cannot eliminate these risks, nor can the inspection anticipate future
events or changes in performance due to changes in use or occupancy. It is recommended that you obtain
as much information as is available about this property, including any seller's disclosures, previous
inspection reports, engineering reports, building/remodeling permits, and reports performed for or by
relocation companies, municipal inspection departments, lenders, insurers, and appraisers. You should also
attempt to determine whether repairs, renovation, remodeling, additions, or other such activities have taken
place at this property. It is not the inspector's responsibility to confirm that information obtained from these
sources is complete or accurate or that this inspection is consistent with the opinions expressed in
previous or future reports.
Items identified in the report do not obligate any party to make repairs or take other action, nor is the
purchaser required to request that the seller take any action. When a deficiency is reported, it is the client's
responsibility to obtain further evaluations and/or cost estimates from qualified service professionals. Any
such follow-up should take place prior to the expiration of any time limitations such as option periods.
Evaluations by qualified tradesmen may lead to the discovery of additional deficiencies which may involve
additional repair costs. Failure to address deficiencies or comments noted in this report may lead to further
damage of the structure or systems and add to the original repair costs. The inspector is not required to

Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX 78711-2188, 1-800-250-8732 or
(512) 459-6544 (http://www.trec.state.tx.us). REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

provide follow-up services to verify that proper repairs have been made.
Property conditions change with time and use. For example, mechanical devices can fail at any time,
plumbing gaskets and seals may crack if the appliance or plumbing fixture is not used often, roof leaks can
occur at any time regardless of the apparent condition of the roof, and the performance of the structure and
the systems may change due to changes in use or occupancy, effects of weather, etc. These changes or
repairs made to the structure after the inspection may render information contained herein obsolete or
invalid. This report is provided for the specific benefit of the client named above and is based on
observations at the time of the inspection. If you did not hire the inspector yourself, reliance on this report
may provide incomplete or outdated information. Repairs, professional opinions or additional inspection
reports may affect the meaning of the information in this report. It is recommended that you hire a licensed
inspector to perform an inspection to meet your specific needs and to provide you with current information
concerning this property.

ADDITIONAL INFORMATION PROVIDED BY INSPECTOR


Texas Inspection Partners may have affiliations with third party service providers ("TPSP") in order to offer
value-added services to our clients. We may also arrange for the TPSP to send literature or make
post-inspection contact with our client's. If you are not comfortable with this arrangement, please let your
inspector know and we will take appropriate action.

LEGEND:
X: Indicates an action item. Please consider immediate repair.
^: Indicates a consideration item. Please consider taking action over the life of the home.

Inspection Environment: ý Occupied ¨ Vacant ¨ New Construction


Weather: Raining & Cold Approximate Temp.: 48° F
Approximate Year of Construction: 1955
DIRECTION: For the purpose of the inspection Right and Left are as you face the street. As an
example the garage is at the right, front corner of this home.
People Present:¨ Owner ¨ Buyer ¨ Agents(s) ¨ Builder ý Inspector Only
Access: ¨ Owner ¨ Agent ý Supra Key ¨ Combo Box ¨ Builder ¨
Report Forwarded To: ý Buyer ¨ Agent ¨ Seller ¨ OTHER ý Via e-mail

ý Client did not attend the inspection, and was therefore unable to accompany the Inspector to observe
the methods and techniques used to conduct the inspection. Client is encouraged to contact the inspector
directly or the Texas Inspection Partners office to discuss the inspection.
¨ The home is occupied. It is not the responsibility of the Inspector to disturb or position personal
belongings of the property owner/occupant (particularly storage items in closets and cabinets) to ensure that
Inspector access to wall, floor and/or ceiling areas is not impeded.

NOTICE: THIS REPORT IS PAID FOR BY AND PREPARED FOR THE CLIENT NAMED ABOVE.
THIS REPORT IS NOT VALID WITHOUT THE SIGNED SERVICE AGREEMENT AND IS NOT
TRANSFERABLE.

The home is an old, ill maintained home. Not all issues are visible and apparent at the time of any
inspection. It is entirely likely that you will find additional issues after you occupy the home. I am
sure that I did not find everything present in this home.

Page 2 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

I. STRUCTURAL SYSTEMS
ý ¨ ¨ ¨ A. Foundations
Type of Foundation(s): Slab on Grade
Comments:
Performance Opinion:
Note: Weather conditions, drainage, leakage, and other adverse factors are able to effect structures, and
differential movements are likely to occur. The inspectors opinion is based on visual observations of
accessible and unobstructed areas of the structure at the time of the inspection. Future performance of the
structure cannot be predicted or warranted.

ý The foundation appears to be performing the function intended


¨ Structural movement and/or settling noted, however, the foundation is supporting the structure at this time
¨ Signs of structural movement noted, suggest that an expert in this field be consulted for further evaluation of
the structure and to provide suggestions as to what, if any, corrective actions should be taken

Method used to inspect the crawlspace: ¨ Entered ¨ Viewed from opening ¨ No Access
Location(s) of crawl space access:
¨ Some areas of the crawlspace is not accessible due to low clearance, piping, ductwork, etc.

SUGGESTED FOUNDATION MAINTENANCE & CARE - Proper drainage and moisture maintenance to all
types of foundations due to the expansive nature of the area load bearing soils. Drainage must be directed
away from all sides of the foundation with grade slopes. In most cases, floor coverings and/or stored articles
prevent recognition of signs of settlement - cracking in all but the most severe cases. It is important to note, this
was not a structural engineering survey nor was any specialized testing done of any sub-slab plumbing
systems during this limited visual inspection, as these are specialized processes requiring excavation. In the
event that structural movement is noted, client is advised to consult with a Structural Engineer who can isolate
and identify causes, and determine what corrective steps, if any, should be considered to either correct and/or
stop structural movement.

ý ¨ ¨ ý B. Grading & Drainage - Comments


The Company does not determine area hydrology, the presence of underground water, or the efficiency
or operation of underground or surface drainage systems.

^: Evidence of ponding water was noted at the rear, right and left of dwelling. Allowing water to pond
around the perimeter of the dwelling can cause swelling of the soil supporting the foundation. Allowing
the soils to move differently under the dwelling will cause damage to the foundation. Proper grading of
soil should be maintained around the perimeter of dwelling to allow proper drainage.

ý ¨ ¨ ý C. Roof Covering Materials


Type(s) of Roof Covering: Shingles - Asphault
Viewed From: Ground
Comments:
A home inspector can not determine the remaining life of any component,
such as the roof.

X: Splash block's and downspout are missing from the front gutter. Splash block's prevent soil erosion
and over moisture saturation of soil in isolated areas from run off water around perimeter of dwelling.

Page 3 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

X: At the time of the inspection it was noted that the roof covering was experiencing signs of wear
that are typical for a roof of this age, such as blistering, loss of aggregate, cupping of tabs and
brittle to the touch. Shingles are broken at the front slope. It is apparent that the roof covering is
nearing the end of its serviceable life.

ý ¨ ¨ ¨ D. Roof Structure & Attic


Viewed From: Attic
Approximate Average Depth of Insulation: 2
Approximate Average Thickness of Vertical Insulation: None
Comments:
Some areas of the attic were inaccessible due to roof slope and household storage.

X: Attic insulation is compacted to the point of being useless..

ý ¨ ¨ ý E. Walls (Interior & Exterior) - Comments


Exterior wall covering type: ý Brick ¨ Composite Wood ¨ Fiber Cement ¨ Stone
ý Wood ¨ Masonry Stucco ¨ Synthetic Stucco ¨ Vinyl ¨ Aluminum
¨ T-1-11 or Plywood ¨ OTHER__________
Exterior trim types: ¨ Fiber Cement ý Wood ¨ Composite Wood ¨ Vinyl ¨ Aluminum

X: I recommend trimming or removal of vegetation growing in contact with the siding at perimeter of
dwelling. Allowing vegetation to grow on the dwelling prevents proper visual monitoring of the dwelling
for insect infestation. Vegetation also promotes moisture levels that will cause siding to rot and create
conducive conditions for wood destroying insects.

Page 4 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

X: I recommend that you seal all holes and protrusions through exterior sheathing at perimeter of
dwelling. This will help prevent moisture penetration of the structure. The hole in the left side of the
home needs to be re-bricked.

X: Exterior siding and trim deteriorated from water penetration or weathering, repair or replace as
necessary at the following locations: garage door casing

X: Several brick sills are damaged.

X: Wall water and sheetrock damage is present at the hall, hall bath, master bath and master
bedroom.

Page 5 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

X: Walls and ceilings are cracked oddly in the LR. This could indicate settlement, however, given
no brick movement it may be related to attic storage load. Only an engineer can determine.

ý ¨ ¨ ý F. Ceilings & Floors - Comments


X: Broken and heavily stained dry wall noted at ceiling in the following rooms or locations: front left
BR, master BR, kitchen, garage, hall bath. These cracks indicate settlement and potential moisture
penetration.

Page 6 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

X: The garage scuttle hole cover is missing. This is a fire hazard.

ý ¨ ¨ ý G. Doors (Interior & Exterior) - Comments


X : The rear exterior door needs paint.

X: The master bathroom door casing has been partially cut out to allow a wheel chair access.
^: Numerous door knobs missing and holes in the walls from knobs

ý ¨ ¨ ý H. Windows - Comments
Note: Signs of lost seals in the thermal pane windows may appear and disappear as
temperature and humidity changes. Some windows with lost seals may not have been evident
at the time of the inspection. Windows only checked for obvious fogging. If some lost seals
were noted, recommend all windows be checked by a specialist for further lost seals.

X: Broken window at following locations: rear and left.


X: Numerous windows are leaking and improperly sealed with putty.

X: Caulking around exterior windows deteriorating.

X: The window sills are reading slightly high moisture content than the wall. Most are degraded as are
loser window casings.

¨ ¨ ý ¨ I. Stairways (Interior & Exterior) - Comments

¨ ¨ ý ¨ J. Fireplace/Chimney - Comments
Number of Fireplaces: 1

Page 7 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

Type: ¨ Metal Box & Flue(s) ¨ Masonry(s)/Brick ¨ Wood Stove ¨ OTHER


¨ This fireplace is intended for radiant heat or gas logs only.
Notes: Unable to check recessed gas valve(s) for leaks.

¨ ¨ ý ¨ K. Porches, Balconies, Decks and Carports - Comments

¨ ¨ ý ¨ L. Other - Comments

II. ELECTRICAL SYSTEMS


ý ¨ ¨ ý A. Service Entrance and Panels - Comments
Main Panel Amps: ý 60 ¨ 100 ¨ 125 ¨ 150 ¨ 200 ¨ 2x200 ¨ Other
Main Panel Location: ¨ Garage ¨ Left Side ¨ Right Side ý Rear Exterior
¨ Utility Room ¨ Other
Sub-Panel Locations: ¨ Garage ¨ Exterior ¨ Utility Room ¨ Attic
¨ Other ý None

X: The main electric panel is a Federal Pacific Stab-Lok panel. This product is known to be inferior
and has several known problem issues. Repair parts are generally not available and it is easy to
damage the panel during installation or repair. No damage noted at this time, however, you should
budget for replacement in the near term. .
X: A 60 amp service is standard in a 1955 home but will be potential too little in a modern home.
There is not enough service to install central air.
X: Proper clearance from ground level not installed at electrical service entrance to dwelling.

ý ¨ ¨ ý B. Branch Circuits, Connected Devices, and Fixtures


Type of Wiring: Romex
Comments:
Type of Wiring: ¨ Copper ¨ Aluminum ¨ Nickel clad Copper
Smoke Detector(s) ¨ Some or all units are inaccessible.
¨ The detectors are interconnected.

GFCI Resets located at: ¨ Kitchen ¨ Master Bathroom ¨ Garage ¨ Hall Bathroom
¨ Pool Equipment ¨Circuit Breakers at the Main Electric Panel ¨ ___________

Arc Fault Circuits Interrupter(s) (AFCI) are only tested when the property is vacant. Resets for the Arc
Fault Circuit(s) are normally located in the breaker panel(s).

Notes: Accessible smoke detector(s) are tested with the test button only. Smoke detectors and/or heat
sensors connected to a security system are not inspected and are beyond the scope of the general
home inspection.

Page 8 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

X: No Ground Fault Circuit Interrupter installed or devise inoperable at .exterior, garage, baths and
kitchen. (In bathrooms GFCI outlets should be installed within six feet of plumbing fixtures and on
lighting circuits over showers and bath tubs. In kitchens GFCI outlets should be installed at all
countertop outlets and at island outlets. In garage and exterior GFCI outlets should be installed at all
outlets except for one outlet designated for refrigerator or freezer in garage.)
X: Electrical branch circuit system throughout dwelling is installed with a two wire/conductor system.
There is no third green color insulated or bare equipment grounding wire/conductor installed. The third
green color insulated or bare wire/conductor carries no current when correctly installed. Its purpose is
to protect the user incase of an equipment malfunction by diverting current to a safe place. User of
electrical system should be aware that this safety wiring/conductor system does not exist in the
dwelling branch circuit wiring/conductor system. It is reccommended that a grounding system be
installed to protect user incase of an equipment malfunction.
X: Outlet/switch cover plates noted missing in numerous locations

III. HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS


ý ¨ ¨ ý A. Heating Equipment
Type of System: None
Energy Source: Gas
Comments:
X: The home is only equipped with window units, space heater jets and ceramic wall heaters. All
ceramic wall heaters and space heater jets must be removed due to CO risk. Recommend a central
heat furnace be installed.

¨ ý ¨ ¨ B. Cooling Equipment:
Type of System:
Comments:
No central air installed.

ý ¨ ¨ ¨ C. Duct System, Chases, and Vents - Comment


Note: We can not check ductwork for cleanliness.
Filter/Cleaner: ý 1” Fiberglass ¨ Washable ¨ Electrostatic ¨ 4” Media ¨ UV Light

Page 9 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

IV. PLUMBING SYSTEM


ý ¨ ¨ ý A. Water Supply System and Fixtures
Location of water meter: Front
Location of main water supply valve: Left
Static water pressure reading: 56
Comments:
Type of Water Pipes: ¨ Galvanized ¨ Copper ¨ CPVC ¨ PEX ¨ Other
Water Source: ý Public ¨ Private Sewer Type: ý Public ¨ Private

X: The kitchen sink and hall tub is rusting out around the edges.

X: The tile counter top is breaking up in the kitchen.

X: The hall tub faucet is damaged and handles are missing.

ý ¨ ¨ ý B. Drains, Wastes, and Vents - Comments


Type of Drain Pipes: ý Cast Iron ¨ PVC ¨ Other

X: The tub tile enclosures are both heavily damaged. Tile is loose and ready to fall off.
X: The master toilet tank is loose.

Page 10 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

ý ¨ ¨ ý C. Water Heating Equipment


Energy Source: Gas
Capacity: 30
The temperature and pressure relief test valve was not operated during this inspection due to the
possibility of the valve not reseating and water damage resulting. Manufacturers recommend that
valves older than three years be removed, cleaned and inspected or replaced.

X: The water heater exhaust vent is broken at the roof level, .

X: Any water heater located in a garage or room adjacent to the garage, through a common door
should be installed a minimum of 18" off the floor to prevent contact with combustible fumes.

X: Type B vent cap missing at water heater flue vent pipe.

X: The water heater main cold input valve is corroded. Replace.

Page 11 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee

I=Inspected NI=Not Inspected NP=Not Present D=Deficiency


I NI NP D

ý ¨ ¨ ¨ D. Hydro-Massage Therapy Equipment - Comments


¨ No visible access to equipment below tub.

V. APPLIANCES
¨ ¨ ý ¨ A. Dishwasher - Comments

¨ ¨ ý ¨ B. Food Waste Disposer - Comments

¨ ¨ ý ¨ C. Range Exhaust Vent - Comments


Vent Method: ¨ Recirculating (vent pipe not required) ¨ Vented ¨ Downdraft
¨ Unit integrated with microwave oven

ý ¨ ¨ ý D. Ranges, Cooktops, and Ovens - Comments

X: The range gas supply valve should be capped if not used.

¨ ¨ ý ¨ E. Microwave Oven - Comments

¨ ¨ ý ¨ F. Trash Compactor - Comments

¨ ¨ ý ¨ G. Mechanical Exhaust Vents and Bathroom Heaters - Comments

¨ ¨ ý ¨ H. Garage Door Operator(s) - Comments

¨ ¨ ý ¨ I. Doorbell and Chimes - Comments

¨ ¨ ý ¨ J. Dryer Vents - Comments


Note: We can not check dry ducts for cleanliness. Any dryer duct should be cleaned regularly.

Page 12 of 15
REI 7A-1 (10/2008)
Report Identification: Todd Rossi, 4610 Nina Lee Page 13 of 15

SUMMARY
Presented for your convenience, please read the entire report.

I. Structural Systems
Grading & Drainage
^: Evidence of ponding water was noted at the rear, right and left of dwelling. Allowing water to pond around the perimeter of the
dwelling can cause swelling of the soil supporting the foundation. Allowing the soils to move differently under the dwelling will cause
damage to the foundation. Proper grading of soil should be maintained around the perimeter of dwelling to allow proper drainage.

Roof Covering Materials


X: Splash block's and downspout are missing from the front gutter. Splash block's prevent soil erosion and over moisture
saturation of soil in isolated areas from run off water around perimeter of dwelling.

X: At the time of the inspection it was noted that the roof covering was experiencing signs of wear that are typical for a roof of
this age, such as blistering, loss of aggregate, cupping of tabs and brittle to the touch. Shingles are broken at the front slope.
It is apparent that the roof covering is nearing the end of its serviceable life.

Roof Structure & Attic


X: Attic insulation is compacted to the point of being useless..

Walls (Interior and Exterior)


X: I recommend trimming or removal of vegetation growing in contact with the siding at perimeter of dwelling. Allowing vegetation to
grow on the dwelling prevents proper visual monitoring of the dwelling for insect infestation. Vegetation also promotes moisture
levels that will cause siding to rot and create conducive conditions for wood destroying insects.

X: I recommend that you seal all holes and protrusions through exterior sheathing at perimeter of dwelling. This will help prevent
moisture penetration of the structure. The hole in the left side of the home needs to be re-bricked.

X: Exterior siding and trim deteriorated from water penetration or weathering, repair or replace as necessary at the following
locations: garage door casing

X: Several brick sills are damaged.

X: Wall water and sheetrock damage is present at the hall, hall bath, master bath and master bedroom.

X: Walls and ceilings are cracked oddly in the LR. This could indicate settlement, however, given no brick movement it may
be related to attic storage load. Only an engineer can determine.

Ceilings & Floors


X: Broken and heavily stained dry wall noted at ceiling in the following rooms or locations: front left BR, master BR, kitchen,
garage, hall bath. These cracks indicate settlement and potential moisture penetration.

X: The garage scuttle hole cover is missing. This is a fire hazard.

Doors (Interior & Exterior)


X : The rear exterior door needs paint.

X: The master bathroom door casing has been partially cut out to allow a wheel chair access.
^: Numerous door knobs missing and holes in the walls from knobs

Windows
X: Broken window at following locations: rear and left.
X: Numerous windows are leaking and improperly sealed with putty.

X: Caulking around exterior windows deteriorating.

X: The window sills are reading slightly high moisture content than the wall. Most are degraded as are loser window casings.
Report Identification: Todd Rossi, 4610 Nina Lee Page 14 of 15

II. Electrical Systems


Service Entrance and Panels
X: The main electric panel is a Federal Pacific Stab-Lok panel. This product is known to be inferior and has several known problem
issues. Repair parts are generally not available and it is easy to damage the panel during installation or repair. No damage noted at
this time, however, you should budget for replacement in the near term. .
X: A 60 amp service is standard in a 1955 home but will be potential too little in a modern home. There is not enough service to
install central air.
X: Proper clearance from ground level not installed at electrical service entrance to dwelling.

Branch Circuits, Connected Devices, and Fixtures


X: No Ground Fault Circuit Interrupter installed or devise inoperable at .exterior, garage, baths and kitchen. (In bathrooms GFCI
outlets should be installed within six feet of plumbing fixtures and on lighting circuits over showers and bath tubs. In kitchens
GFCI outlets should be installed at all countertop outlets and at island outlets. In garage and exterior GFCI outlets should be
installed at all outlets except for one outlet designated for refrigerator or freezer in garage.)
X: Electrical branch circuit system throughout dwelling is installed with a two wire/conductor system. There is no third green color
insulated or bare equipment grounding wire/conductor installed. The third green color insulated or bare wire/conductor carries no
current when correctly installed. Its purpose is to protect the user incase of an equipment malfunction by diverting current to a safe
place. User of electrical system should be aware that this safety wiring/conductor system does not exist in the dwelling branch
circuit wiring/conductor system. It is reccommended that a grounding system be installed to protect user incase of an equipment
malfunction.
X: Outlet/switch cover plates noted missing in numerous locations

III. Heating, Ventilation, and Air Conditioning Systems


Heating Equipment
X: The home is only equipped with window units, space heater jets and ceramic wall heaters. All ceramic wall heaters and space
heater jets must be removed due to CO risk. Recommend a central heat furnace be installed.

IV. Plumbing Systems


Water Supply System and Fixtures
X: The kitchen sink and hall tub is rusting out around the edges.

X: The tile counter top is breaking up in the kitchen.

X: The hall tub faucet is damaged and handles are missing.

Drains, Wastes, and Vents


X: The tub tile enclosures are both heavily damaged. Tile is loose and ready to fall off.
X: The master toilet tank is loose.

Water Heating Equipment


X: The water heater exhaust vent is broken at the roof level, .

X: Any water heater located in a garage or room adjacent to the garage, through a common door should be installed a minimum
of 18" off the floor to prevent contact with combustible fumes.

X: Type B vent cap missing at water heater flue vent pipe.

X: The water heater main cold input valve is corroded. Replace.

V. Appliances
Ranges, Cooktops, and Ovens
X: The range gas supply valve should be capped if not used.
Report Identification: Todd Rossi, 4610 Nina Lee Page 15 of 15

READ THESE NOTICES


ALL UTILITIES MUST BE TURNED ON PRIOR TO MECHANICAL OR COMBINATION INSPECTIONS. THE INSPECTOR IS
NOT REQUIRED TO TURN ON UTILITIES, LIGHT PILOTS OR INSPECT THE CONDITION OF METERING DEVICES.

Vacant Houses
The following items are the most common problems found after a house has been vacant for a week or more, and for which this inspection
company will not be responsible:
1. Sewer and drain lines stopping up.
2. Leaks at faucets - seals and washers dry out (kitchen, bathroom, and utility)
3. Leaks at dishwashers - seals dry out.
4. Disposal locking up.
5. Water heaters leak at drain valves.
6. Electric water heaters - water drained, but power not turned off - damage to heating elements and thermostats.
7. Supply line for water heaters - cut off valve - leaking.
8. Gas water heaters and gas furnaces - if gas has been turned off - thermocouple (pilot generator) fails.
9. Foundations should be watered at least once or twice a week if house is vacant in the hot dry season.

INSPECTIONS ARE PERFORMED FOR THE PERSON, INDIVIDUAL OR COMPANY


NAMED ON THE REPORT AND IS NOT TRANSFERABLE TO ANY OTHER PERSON.

Important Limitations and Disclaimers


1. This Inspection Report reports only the items listed and only on the present condition of those items. This Report reflects only if the items inspected are
observed to be 'operable" or "inoperable' at the present time of inspection, that is, whether such items at this time are observed to serve the purpose of
which they are ordinarily intended.

2. This Report reflects only those items that are reasonably observable at the time of inspection. NO REPRESENTATION OR COMMENT is made concerning
any latent defects or defects not reasonably observable at the time of the inspection or of items which require the removal of major or permanent coverings
or furniture. For example, but without limitation, recent repairs, painting, covering, or furniture may conceal prior or present leak damage, which is not
reasonably observable by the inspector and no representation, or comment can be made.

3. NO REPRESENTATION IS MADE CONCERNING ANY OTHER CONDITION OR THE FUTURE PERFORMANCE OF ANY ITEM. NO
REPRESENTATION IS MADE AS TO THE ITEMS NOT SPECIFICALLY COMMENTED UPON. ALL WARRANTIES, EXPRESS OR IMPLIED, NOT
SPECIFICALLY STATED HEREIN ARE EXCLUDED AND DISCLAIMED.

4. If a comment is made concerning the condition of any item, the Customer is URGED to and AGREES to contact a SPECIALIST to make further inspections
of evaluations of that item, if customer intends to rely on this Report.

5. Customer must notify Company in writing of any complaints within (7) days of inspection and must thereafter allow prompt reinspection of the item
complained of; otherwise, all claims for damages arising out of such complaint are waived by Customer.

6. If Customer institutes any legal action concerning the inspection, and fails to prevail on all of the causes of the action alleged, Customer shall be liable to
Company for all of ft attorney's fees incurred in such action.

7. Actual damages for any breach of contract or warranty, negligence or otherwise are limited to the amount of the inspection fee.

8. Customer, by accepting this Report, or relying upon it any way, expressly agrees to those Limitations and Disclaimers.

9. Security devices, alarms, smoke detectors, fire alarms and related systems are not inspected. It is recommended that these devices systems if present, be
property inspected by a qualified technician. If these systems devices are not present at the property being inspected, it is the responsibility of the purchaser
to provide security and fire protection as deemed necessary by the level of personal safety desired.

NOTICE: YOU THE BUYER HAVE OTHER RIGHTS AND REMEDIES UNDER THE TEXAS DECEPTIVE TRADE PRACTICES CONSUMER PROTECTION
ACT WHICH ARE IN ADDITION TO ANY REMEDY WHICH MAY BE AVAILABLE UNDER THIS CONTRACT. FOR MORE INFORMATION CONCERNING
YOUR RIGHTS, CONTACT THE CONSUMER PROTECTION DIVISION OF THE ATTORNEY GENERALS OFFICE, YOUR LOCAL DISTRICT / COUNTY
ATTORNEY, OR THE ATTORNEY OF YOUR CHOICE.

Date: 02/11/2010 Job No.:GW20100211-02 BY: Glenn Wharton, TREC License #3772