Escolar Documentos
Profissional Documentos
Cultura Documentos
Plumbing andSanitary
and Sanitary System
WaterSupplyandDistribution
pp y
System
DrainageSystem
D i
S t
Plumbing Fixtures
PlumbingFixtures
Storm WaterSystem
WaterSupply andDistributionSystem
WaterSupply
Water
Supply andDistributionSystem
and Distribution System
BasicPropertiesofWater
WaterCycle
Water Cycle
SourcesofWater
WaterTreatmentandPurification
W t T t
t d P ifi ti
Wells
Pumps
P
WaterStorage forDomesticUse
ValvesandControls
ColdWaterDistributionSystem
HotWaterDistributionSystem
Advantages
Disadvantages
Waterissoft&pureandis
Water is soft & pure and is
suitableforthehotwater
supplysystem
pp y y
Onlyasourceduringthe
Only a source during the
wetseason
Storage
Storagebecomesa
becomes a
breedingplacefor
mosquitoes
Roofsmaynotbeclean
Advantages
g
Disadvantages
g
Usuallyeasytoacquire
andinlargequantities.
Usedforirrigation,
df i i i
industrialpurposesand,
when treated for
whentreated,for
communitywatersupply.
Containsalargeamounts
ofbacteria,organic&
inorganicsubstances;
Purification&treatmentis
necessar
necessary.
Advantages
Usuallyhasanabundant
y
supply;requireslesstreatment
becauseofnaturalfiltering.
Disadvantages
May
Mayhaveorganicmatter
have organic matter
&chemicalelements
usuallytreatmentis
suggested.
CAUSE
EFFECTS
TREATMENT
Acidity
ContainsCarbon
Dioxide
Corrosion ofnon
ferrouspipes
Rusting
Rustingandclogging
and clogging
ofsteelpipes
Passing thewater
throughabedof
crushed marble or
crushedmarbleor
limestonetoachieve
alkalinity,oradding
sodium silicate
sodiumsilicate
Hardness
Presenceof
magnesiumand
calcium salts
calciumsalts
Cloggingofpipes
Impairedlaundry
and cooking
andcooking
Boiling
Introduction ofwater
softeners made up of
softenersmadeupof
Zeolite
Turbidity
Siltormudin
Discoloration
surfaceoringround
f
i
d Badtaste
B dt t
Filtration
CAUSE
EFFECTS
TREATMENT
Color
PresenceofIron
andManganese
Discolorationof
fixturesandlaundry
Chlorinationor
ozonation andfile
filtration
Pollution
Contaminationby
organicmatteror
sewage
Disease
Chlorination
Aeration
Coagulation Flocculation
Sedimentation
Filtration
Disinfection
Coagulation
Coagulation Flocculation
Coagulation chemicalprocessinwhichthecoagulant
reactswiththesedimenttomakeitcapableofcombining
p
g
intolargerparticles.
Flocculation physicalprocessinwhichthesediment
particlescollidewitheachotherandsticktogether.
l
ll d
h
h h
d
k
h
Sedimentation
isaphysical
is a physical watertreatment
water treatment process
process
usedtosettleoutsuspendedsolidsin
g
y
waterundertheinfluenceof gravity.
Disinfection
Di i f ti
isanexcavationorstructurecreatedinthegroundbydigging,driving,
boringordrillingtoaccess groundwater inunderground aquifers.Thewell
wateris drawn byan electricsubmersiblepump,atrashpump,avertical
turbinepump,a
p p, handpump
p p ora mechanicalpump
p p
GeneralTypesofWell
ShallowWell
DeepWell
isanexcavationorstructurecreatedinthegroundbydigging,driving,
boringordrillingtoaccess groundwater inunderground aquifers.Thewell
wateris drawn byan electricsubmersiblepump,atrashpump,avertical
turbinepump,a
p p, handpump
p p ora mechanicalpump
p p
GeneralTypesofWell
ShallowWell
DeepWell
areexcavationswithdiameterslargeenoughtoaccommodateoneor
are excavations with diameters large enough to accommodate one or
moremenwithshovelsdiggingdowntobelowthe watertable.Theycan
belinedwith laidstones orbrick;extendingthisliningupwardsabovethe
groundsurfaceintoawallaroundthewellservestoreduceboth
contaminationandinjuriesbyfallingintothewell.Amoremodern
methodcalledcaissoning usesreinforcedconcreteorplainconcretepre
castwellringsthatareloweredintothehole.
Thesearedugwithearthaugersareusuallylessthan30meters(100ft)
These are dug with earth augers are usually less than 30 meters (100 ft)
deep.Thediameterrangesfrom2to30inches.Thewellislinedwith
metal,vitrifiedtileorconcrete.
Thismethodmakesuseofahighvelocitystreamofwatertoexcavate
This method makes use of a high velocity stream of water to excavate
theholeandtocarrytheexcavatedmaterialoutofthehole.Ittherefore
requiressometypeofpump,eithermotororhandpowered,of
reasonablecapacity,aswellasasupplyofwater.Itispossibletoseparate
thewaterandtheexcavatedmaterialinasettlingpoolortankandto
reusethewater,thusminimizingthequantityrequired.Sincethismethod
dependsontheerosiveactionofwater,itisobviousthatextremelyhard
materials cannot be penetrated
materialscannotbepenetrated.
Isadeviceusedtomovefluids,suchasliquidsorslurries.
Apumpdisplacesavolumebyphysicalormechanicalaction.
GeneralTypesofPump
ReciprocatingPump
CentrifugalPump
TurbinePump
SubmersiblePump
Jet(Ejector)Pump
PistonPump
SumpPump
Aturbinepumphasaverticalturbinelocatedbelow
groundwaterlevelsandadrivingmotorlocatedat
ground
Isbasicallyacentrifugalpumpcompletewith
electricmotorswhicharepositionedunderwaterina
suitableboredholethatdeliversthewatertothe
surface
Inthejetejectorpump,fluidpassesthrougha
venturi nozzle(see venturi tube)anddevelops
a suction thatcausesasecondstreamoffluidtobe
entrained
areusedinapplicationswhereexcesswatermust
bepumpedawayfromaparticulararea.
apumpusedtoremovewaterthathas
accumulatedinawatercollectingsumppit.
Doesnothaveanypressureconcernsbutrelieson
gravitytosupplywatertofixturesbelow.
Use in overhead feed system
Useinoverheadfeedsystem
isanoldertypeofdomestichotwaterheater
which uses a separate hot water tank which
whichusesaseparatehotwatertankwhich
isconnectedtoaheatingboileraswellasto
domestichotwaterpipinginthehome.
Madeofgalvanizedsteelsheet,
copperorstainlesssteel.Standardworking
pressurelimitis85to150psi
StorageBoiler
g
Largehotwatertank(60130cmindiameter;
5mmaxlength).Madeofheavydutymaterial
sheetsappliedwithrustproofpaint.Standard
workingpressurelimitis65to100psi.
ki
li it i 65 t 100 i
T
TypesofValves
fV l
GateValve
Globe Valve
GlobeValve
CheckValve
Angle Valve
AngleValve
FootValve
Safety Valve
SafetyValve
InternationalStandardforValve
ISO InternationalStandardOrganization
ASTM
ASTM AmericanSocietyforTestingand
American Society for Testing and
Materials
ASME AmericanSocietyofMechanical
Engineers
API AmericanPetroleumInstitute
JIS JapaneseIndustrialStandard
DIN Deutsches Institut fr Normungg ((German
InstituteforStandardization)
PNS PhilippineNationalStandard
WedgeType
GateValveSymbol
DoubleDiscValve
Symbol
PlugTypeDiscValve
ConventionalDiscValve
CompositionDiscValve
Symbol
SwingCheckValve
LiftCheckValve
VerticalCheckValve
HorizontalCheckValve
Amanuallyoperatedvalvewithitsoutletopeningorientedatrightanglestoits
p
g;
g
g
pp
inletopening;usedforregulatingtheflowofafluidinapipe.
Symbol
areatypeofcheckvalveandareplacedatthepump'swetwell.Unlikeother
,
g
pp
valves,afootvalveiscreatedwithalargerflowareathantheactualpipesizeto
makesurethatthereislessheadloss.
Symbol
Symbol
packinguponametalsheet.
KeyCock Operateswitharoundtaperingplugaroundto
fitametalsheet.
BallFaucet Constructedwithaballconnectedtothe
handle.
HoseBibb Awaterfaucetmadeforthethreaded
attachmentofahose.
The water service pipe, water distribution pipes, and the necessary connecting
pipes,
i
fitti
fittings, control
t l valves
l
and
d allll appurtenances
t
iin or adjacent
dj
t tto th
the structure
t t
or
premises.
PartsofWaterDistributionSystem
Service Pipe Thepipefromthewatermainorothersourceofpotablewatersupply
ServicePipe
Th i f
th
t
i
th
f t bl
t
l
tothewaterdistributionsystemofthebuildingserved.
WaterMeter Deviceusedtomeasureinlitersorgallonstheamountofwater
th t
thatpassesthroughthewaterservice.
th
h th
t
i
DistributionPipe/SupplyPipe Apipewithinthestructureoronthe
premiseswhichconveyswaterfromthewaterservicepipeormetertothepointofutilization.
Riser Awatersupplypipethatextendsonefullstoryormoretoconveywaterto
Riser
A water supply pipe that extends one full story or more to convey water to
branchesortoagroupoffixtures.
FixtureBranch Thewatersupplypipebetweenthefixturesupplypipe&thewater
distributing pipe
distributingpipe.
FixtureSupply Awatersupplypipeconnectingthefixturewiththefixturebranch.
Advantages
g
1.Eliminatecost ofpumps&tanks
Disadvantages
g
1.Pressurefromwatermainisinadequate
tosupplytallbuildings.
2.Water
2
Water supplyisaffectedduringpeakload
supply is affected during peak load
hour.
AirPressure
System
1.Withcompactpumpingunit
2.Sanitaryduetoairtightwater
chamber.
chamber
3.Economical(smallerpipediameter)
4.Lessinitial construction&
maintenancecost.
1.Watersupplyisaffectedbylossof
pressure inside the tank in case of
pressureinsidethetankincaseof
powerinterruption.
Advantages
g
Disadvantages
g
AirPressure 5.Oxygeninthecompressedairserves
aspurifying agent.
System
6 Ad t bl Ai
6.AdaptableAirpressure
7.AirPressureserves zoneofabout
10storesintervals
1.Waterisnotaffectedbypeakload
Overhead
Feed System hour.
1.Water issubjecttocontamination
3.Timeneededtoreplacebrokenparts
doesnotaffectwatersupply
3.Occupiesvaluablespace
4.Requiresstronger foundationand
otherstructuretocarryadditionalload
oftankandwater.
ItismadeoutofaMildSteeldrawnthroughadieandweldedcastinto
It i
d
t f Mild St l d
th
h di
d ld d
ti t
6.00mlong.However,steelpipeissubjecttodepositsofsaltsandlimewhich
graduallyaccumulateandeventuallychoketheflowofwater.Thistypeofpipe
is corroded by alkaline and acid water That is why when used for hot water
iscorrodedbyalkalineandacidwater.Thatiswhywhenusedforhotwater
line,itdeterioratesfasterthancoldwatersupplypipe.
PlasticorSyntheticPipe
Rigid Type
RigidType
Flexible Type
FlexibleType
1.PolyvinylChloride(PVC)
1.Polyethylene(PE) Coilformat30m
2.ChlorinatedPolyvinylChloride(cPVC)
y y
(
)
2.Polybutylene
y y
((PB)up
) p to150mincoil
Thisisdurableandisconvenientlyinstalledinmostoftheplumbingneedsinbuilding
This
is durable and is conveniently installed in most of the plumbing needs in building
whicharelessthan25storeys highbecausewaterusuallyleaksatjointsdueto
vibrations.
AcidResistantCastIronPipe
p
Madeofanalloyofcastironandsilicon.Itiscommonlyinstalledinchemical
Made of an allo of cast iron and silicon It is commonl installed in chemical
laboratorieswhereacidwastearebeingdischarged
AsbestosPipe
Madeofasbestosfibersandportland cement.Thethicknessistwicethatofstandard
castiron.Mostsuitedforembedmentonconcretestructures.
BituminousFiberSewerPipe
Cheapest,lightinweight,recommendedforhousesewerandseptictankinstallation.It
could take slight soil movement without danger of cracking or pulling out of its joint
couldtakeslightsoilmovementwithoutdangerofcrackingorpullingoutofitsjoint.
VitrifiedClayPipe
Madefromclayandwithalengthof0.75mtreatedwithglazedcompound.Thisis
g y es sta t to ost ac ds a d s e su ted u de g ou d sta at o s o
g
highlyresistanttomostacidsandiswellsuitedinundergroundinstallationsworking
eitheraspublicorhousesewer,orstormdrain
Oneoftheoldestplumbingmaterials.Leadishighlyresistantandisverysuitableto
undergroundinstallation.Butbecauseitispoisonousandinjurioustohumanhealth,itis
neverrecommendedtoconveywaterhumanconsumption.
Thisisbetterthansteelpipesforplumbinginstallation,becauseitismoreresistantto
acidwastethanthesteelpipe
BrassPipe
p
Themostexpensiveofalltypesofpipe.Madeofanalloyofzincandcoppermixedata
proportionof15%and85%respectively.Thebrasspipeissuperiormaterialforwaste
andwaterinstallationbecauseofitssmoothsurfaceasidefromitshighresistanceto
acids.
acids
CopperPipes
Adurablematerialwhichisextremelycorrosiveresistanteasiesttoinstall.
DrainageSystem
Drainage System
DrainageSystem
BasicPrincipleGoverningtheNationalPlumbingCode
All premisesintendedforhumanuseorhabitationshallbeprovidedwithasupplyofpureand
wholesomewater,neitherconnectedtounsafewatersupplynorsubjecttobackfloworback
siphonage.
Plumbingfixtures,devicesandappurtenancesshallbesuppliedwithwaterinsufficientvolumeand
pressure adequatetofunctionsatisfactorilyandwithoutunduenoise.
adequate to function satisfactorily and without undue noise
Plumbingshallbedesignedandadjustedto usetheminimumquantityofwater consistentwith
properperformanceandcleaning.
Devicesforheatingandstoringwatershallbesodesignedandinstalledastopreventdangersfrom
explosionthroughoverheating.
Everybuildingabuttingonastreet,alleyoreasement withapublicsewershall connectitsplumbing
fixturestothesewersystem.
Each family dwelling unit shallhave
Eachfamilydwellingunit
shall have atleastonewatercloset,
at least one water closet onekitchentypesink,alavatoryand
one kitchen type sink a lavatory and a
a
bathtuborshower tomeetthebasicrequirementsofsanitationandpersonalhygiene.
Plumbingfixtures shallbemadeof smoothnonabsorbentmaterial,freefromconcealedfouling
surfaces andshallbe locatedinventilatedenclosures.
The drainagesystem shallbedesigned,constructedandmaintainedtosafeguardagainstfouling,
depositofsolids,cloggingandwithadequatecleanoutssoarrangedthatthepipesmaybereadily
cleaned.
Drainage System
DrainageSystem
BasicPrincipleGoverningtheNationalPlumbingCode
Drainage System
DrainageSystem
BasicPrincipleGoverningtheNationalPlumbingCode
Drainage System
DrainageSystem
SubsystemsoftheSanitarySystem
SoilDrainageSystem
Soil Drainage System
WasteDrainageSystemorSanitaryDrainageSystem
StormDrainageSystem
VentSystem
Vent System
Drainage System
DrainageSystem
SubsystemsoftheSanitarySystem
SoilDrainageSystem
Soil Drainage System
Thepipingthatconveysthe
discharge of water closets or
dischargeofwaterclosetsor
fixtureshavingsimilarfunctions
(containingfecalmatter),withor
without the discharges from other
withoutthedischargesfromother
fixtures
SoilDrainageSystem
Drainage System
DrainageSystem
SubsystemsoftheSanitarySystem
WasteDrainageSystemorSanitaryDrainageSystem
Waste Drainage System or Sanitary Drainage System
Thepipingthatreceivestheliquiddischarge,fromplumbingfixtures
otherthanthosefixtures(waterclosets)receivingfecalmatter.This
pipingisfreeoffecalflow.
Drainage System
DrainageSystem
SubsystemsoftheSanitarySystem
StormDrainageSystem
Storm Drainage System
Thepipingsystemthatreceivesclearwaterdrainagefromleaders,
downspouts,surfacerunoff,groundwater,subsurfacewater,
condensatewater,coolingwaterorothersimilardischargesandconveys
themtothepointofdisposal.Allsanitarywastesmustbeexcluded.
Drainage System
DrainageSystem
SubsystemsoftheSanitarySystem
VentSystem
Vent System
thepipingsystemthatreceivesa
floworairtoorfromadrainage
systemortoprovideacirculation
ofairwithinsuchsystemto
protecttrapsealsfromsiphonage
orbackpressure.
VentSystem
Drainage System
DrainageSystem
GENERALREQUIREMENTSFORAPROPERLYDESIGNEDDRAINAGESYSTEM
1. The
1
Thepipingmustbeairtight,gastightandwatertight.
piping must be air tight gas tight and water tight
2. Eachplumbingfixture,exceptthosewithintegraltraps,shallbeseparatelytrappedbyan
approvedtypewatersealtrap.Thisistopreventodorladenandgermladentoriseoutof
g y
g
thedrainagesystemandcontaminatethesurroundingairintheroom.
3. Eachplumbingfixturetrapshallbeprovidedwithventpipes.Thisistoprotectthe
drainagesystemagainstsiphonage andbackpressureandtoassureair
circulationthroughoutthedrainagesystem.
4 Acleanout,easilyaccessible,shallbeprovidedforinspectionorcleaningofthepiperun.
4.
A cleanout easily accessible shall be provided for inspection or cleaning of the pipe run
Thelocationofthecleanoutshallbe:
Attheupperendofeveryhorizontalwasteorsoilpipe.
Ateverychangeofhorizontaldirectionofnotmorethan22.5degrees
Within1.5m(5)insidethepropertylinebeforethehousesewerconnection
Atevery15m(50)toahorizontalrunofasoilorwastepipe.
5. Allhorizontalpipingshallberuninpracticalalignmentandatauniformgradeofnotless
than 2% or 2 cm per meter toward the point of disposal
than2%or2cmpermetertowardthepointofdisposal.
Drainage System
DrainageSystem
GENERALREQUIREMENTSFORAPROPERLYDESIGNEDDRAINAGESYSTEM
6. All
6
Allhorizontalpipingshallbesupportedandanchoredatintervalsnottoexceed3meters.
horizontal piping shall be supported and anchored at intervals not to exceed 3 meters
7. Verticalpipingshallbesecuredatsufficientlycloseintervalstokeepthepipein
alignment.Stacksshallbeproperlysupportedattheirbases.
Drainage System
DrainageSystem
DEFINITIONFROMNPC1999EDITION
HOUSE/BUILDINGDRAIN
HOUSE
/ BUILDING DRAIN partofthelowesthorizontalpipingofaplumbingsystem,
part of the lowest horizontal piping of a plumbing system
whichreceivesthedischargesfromthesoil,wasteandotherdrainagepipesinsideofa
buildingandconveysittothehouseseweroutsideofthebuilding
HOUSE/BUILDINGSEWERextends
HOUSE
/ BUILDING SEWER e tends fromthehousedrainatapoint0.60meters
from the ho se drain at a point 0 60 meters
fromtheoutsidefaceofthefoundationwallofabuildingtothejunctionwiththe
streetsewerortoanypointofdischarge,andconveyingthedrainageofonebuilding
g
site.Nohouse/buildingsewershallbesmallerthan150mmindiameter,norlessin
sizethanthehouse/buildingdrain
WASTEPIPE conveysonlywastewaterorliquidwastefreeoffecalmatter
SOILPIPE
SOIL
PIPE anypipewhichconveysthedischargeofwatercloset,urinalorfixtures
any pipe which conveys the discharge of water closet urinal or fixtures
havingsimilarfunctions,withorwithoutthedischargesfromotherfixturestothe
buildingdrainorbuildingsewer
SOILSTACKPIPE
SOIL
STACK PIPE averticalsoilpipeconveyingfecalmatterandwastewater.
a vertical soil pipe conveying fecal matter and waste water
VENTPIPE usedforensuringthecirculationofairinaplumbingsystemandfor
relievingthenegativepressureexertedontrapseals
Drainage System
DrainageSystem
DEFINITIONFROMNPC1999EDITION
VENTSTACK theverticalventpipeinstalledprimarilyforprovidingcirculationofairtoand
fromanypartofthesoil,wasteofthedrainagesystem
SEPTICTANKA watertightcoveredreceptacledesignedandconstructedtoreceive
thedischargeofsewagefromabuildingsewer,separatesolidsfromtheliquid,digest
organic matter and store digested solids the clarified liquids to discharge for final
organicmatterandstoredigestedsolidstheclarifiedliquidstodischargeforfinal
disposal.
PRIVATESEWAGEDISPOSALSYSTEM aseptictankwiththeeffluentdischarging
p
,
p g p
y
intoasubsurfacedisposalfield,seepagepitsorofsuchotherfacilitiesormaybe
permittedbytheplumbingcode.
ROOFGUTTER thewatercollectorattheeavesofthebuilding
DOWNSPOUT Averticalpipewhichconveysrainwater,alsoknownas
conductor or rain water
conductororrainwater
STORMDRAIN Receivesstormwater,clear,rainorsurfacewaterwaste(SD)
CATCHBASIN Areceptacleinwhichliquidsareretainedforasufficientperiodof
timetoallowmaterialstosettletodeposit.
TRAP Afittingordevicedesignedandconstructedtoprovide,whenproperlyvented,a
liquidsealwhichpreventsthebackflowoffoulairormethanegaswithoutmaterially
affectingtheflowofsewageorwastewaterthroughit
Drainage System
DrainageSystem
MATERIALSUSEDFORTHEPLUMBINGDRAINAGESYSTEM
*Approved
ApprovedbyNationalPlumbingCode
by National Plumbing Code
ExcretaDrainagePiping
1.
2
2.
3.
4.
5.
6.
7.
8.
9
9.
10.
Castiron
Ductile iron
Ductileiron
Galvanizedsteel(shallnotbeusedunderground.Keptatleast152mmaboveground)
Galvanizedwroughtiron (shallnotbeusedunderground.Keptatleast152mm
aboveground)
Lead
Copper
Brass
Series 1000 PVC DMV
Series1000,PVC,DMV
Extrastrengthvitrifiedclaypipe (shallnotbeusedaboveground.Atleast300mmbelow
finishgroundlevel.)
11. Approvedmaterialhavingsmoothanduniformbore
NOTE:ABSandPVCDWVcanbeusedinhighrisebuildingsatthediscretionoftheRMPandwith
thefullconsentoftheowner.
Drainage System
DrainageSystem
MATERIALSUSEDFORTHEPLUMBINGDRAINAGESYSTEM
*Approved
ApprovedbyNationalPlumbingCode
by National Plumbing Code
DrainageFitting
1.
2
2.
3.
4.
5.
6.
7.
8.
CastIron
Malleable
Lead
Brass
Copper
ABS(AcrylonitrileButadieneStyrene)
PVC(Polyvinylchloride)
Vitrifiedclay
VentPipes
1.
2
2.
3.
4.
5.
6.
7.
8.
9
9.
Castiron
Ductile cast iron
Ductilecastiron
Galvanizedsteel
Galvanizedwroughtiron
Lead
Copper
Brass
Schedule40,ABS,DWV
Series 1000 PVC DWV
Series1000,PVC,DWV
Drainage System
DrainageSystem
MATERIALSUSEDFORTHEPLUMBINGDRAINAGESYSTEM
*Approved
ApprovedbyNationalPlumbingCode
by National Plumbing Code
VentStack
1.
2
2.
3.
4.
Copper
Cast iron
Castiron
Galvanizedwroughtiron
PVC
Vent Fittings
VentFittings
1.
2.
3
3.
4.
5.
6.
7.
8.
CastIron
Galvanizedmalleableiron
Galvanized steel
Galvanizedsteel
Lead
Copper
Brass
ABS
PVC
Downspout(Interior)
1.
2
2.
3.
4.
5.
6.
7.
8.
Castiron
Galvanized steel
Galvanizedsteel
Iron
Brass
Copper
Lead
Sched 40,ABS,DMV
Series1000,PVC,DWV
1.
2.
3.
4.
5.
G.I.pipe,sch.30
CISP,S.W.
Copper tube, type DWV
Coppertube,typeDWV
Sch.40,ABS,DWV
Series1000,PVC,DWV
Downspout (MediumHeightBldg)
Downspout
(Medium Height Bldg)
Drainage System
DrainageSystem
GRADESOFHORIZONTALPIPING
Allhorizontalpipingshallberuninpractical
All
horizontal piping shall be run in practical
alignmentandatauniformgradeofnotless
thantwo(2%)percentor20mmriseper
meterlength,andshallbesupportedor
anchoredatintervalsnotexceeding3.0m
(10feet).Allstacksshallbeproperly
supportedattheirbasesandallpipesshall
be rigidly secured Two inches (2))riseper
berigidlysecured.Twoinches(2
rise per
everyonehundred(100) length.
Asoilbranchhavingapitchofmorethan2%
hasthetendencyofwasteseparation.The
waterflowfasterandheavysuspended
materialsareleftanddepositedatthe
bottomofthepipe.
Drainage System
DrainageSystem
CHANGESINDIRECTION
Allchangesindirectionshallbemadebytheappropriatefortyfivedegree(45)
All
changes in direction shall be made by the appropriate forty five degree (45)
wyes,halfwyes,longsweepquarterbends,exceptthatsinglesanitaryteesmaybe
usedonverticalstacks,andshortquarterbendsmaybeusedinsoilandwastelines
wherethechangeindirectionofflowisfromthehorizontaltothevertical.Teesand
crossesmaybeusedinventpipes.
Drainage System
DrainageSystem
PROHIBITEDFITTINGS
Nodoublehub,doubleTbranchshallbeusedonhorizontalsoilorwasteline.The
No
double hub double T branch shall be used on horizontal soil or waste line The
drillingandtappingofhousedrains,soilwasteorventpipesandtheuseofsaddle
hubsandbendsareprohibited.
Drainage System
DrainageSystem
TRAPSWHEREREQUIRED:
EEachplumbingfixture,exceptthosewithintegraltraps,shallbe
h l bi fi t
t th
ith i t
lt
h ll b
separatelytrappedwithanapprovedtypewatersealtrap:
Onlyonetrapshallbepermittedonatraparm(portionofafixture
drainbetweenatrapandthevent)
Onetrap,centrallylocated,mayservethreesinglecompartment,
sinksorlaundrytubsorlavatories,adjacenttoeachotherandin
the same room, where their waste outlets are not more than 0.75m
thesameroom,wheretheirwasteoutletsarenotmorethan0.75m
apart.
Drainage System
DrainageSystem
SIZEOFTRAPS
Th
Thetrapshallbethesamesizeasthetraparmtowhichitis
t
h ll b th
i
th t
t hi h it i
connected.
Eachfixturetrapshallhaveatrapsealofwaterofnotlessthan51
mmandnotmorethan102mm(exceptwhereadeepersealis
foundnecessarybytheAdministrativeAuthorityforspecial
conditions.
Drainage System
DrainageSystem
INSTALLATIONOFTRAPS
Th
Thedevelopedlengthofthetraparm(measuredfromthetopof
d l
d l th f th t
(
df
th t
f
closetringtoinneredgeofvent)ofawaterclosetorsimilarfixture
shallnotexceed1.8m.
Fortraparm76mmdia orlarger,acleanoutisrequiredfora
changeofdirectionofgreaterthan22.
Drainage System
DrainageSystem
TYPESOFPERMISSIBLETRAPS
TheCommonPTrap
Usedforlavatories,kitchensinks,laundrytubs,&urinals
MaterialscommonlyusedforthePtrap:nickel,chrome
Materials commonly used for the P trap: nickel chrome
platedbrass,Galvanizedmalleablecopper,&PVC.
Drainage System
DrainageSystem
TYPESOFPERMISSIBLETRAPS
TheDeepSealPTrap
WatersealisabouttwicethesizeofThecommonPtrap
Usedforextremeconditionsbecauseresealingqualityis
Used for extreme conditions because resealing quality is
greater
Drainage System
DrainageSystem
TYPESOFPERMISSIBLETRAPS
TheStandTrap
Usedforfixturessuchasslopsinksthatareusuallybuiltlowinthe
ground leaving very little space for a foundation & a trap
ground,leavingverylittlespaceforafoundation&atrap
Servesasawaterseal&structuralsupportforthefixture
Drainage System
DrainageSystem
TYPESOFPERMISSIBLETRAPS
TheRunningTrap
Usedwithinthelineofthehousedrain
Drainage System
DrainageSystem
TYPESOFPERMISSIBLETRAPS
TheDrumTrap
Hasalargediameter(around0.16m)
Used for fixtures that discharge large amount of water (bathtubs
Usedforfixturesthatdischargelargeamountofwater(bathtubs,
showerorfloordrains)
Drainage System
DrainageSystem
INSTALLATIONOFTRAPS
Th
Theverticaldistancebetweenafixtureoutlettailpieceandthetrap
ti l di t
b t
fi t
tl t t il i
d th t
weirshallnotexceed0.60minlength.
HorizontalDistanceofTrapArms
Horizontal Distance of Trap Arms
TrapArm
Diameter
Distanceto
Vent
32mm
0.76m
38mm
1.07m
51
51mm
1 52
1.52m
76mm
1.83m
102mm >
3 05m
3.05m
Note:Innocaseshallthetrap
distancebelessthan2timesthe
diameterofthetraparm.
Drainage System
DrainageSystem
CLEANOUTSREQUIRED
Attheupperterminalofeveryhorizontalsewerorwasteline
pp
y
Ateachrunofpipingmorethan15meters(50feet)intotal
developedlengthatevery15m(50ft)oftotaldevelopedlengthora
fraction thereof
fractionthereof
Additionalcleanoutshallbeprovidedonahorizontallinewithan
aggregateoffsetangleexceeding135
Insidethebuildingneartheconnectionbetweenthebuildingdrain
Inside the building near the connection between the building drain
andthebuildingsewerorinstalledoutsidethebuildingatthelower
endofthebuildingdrainandextendedtograde.
CLEANOUTSNOT REQUIRED
Onahorizontaldrainlessthan1.5minlengthunlesssuchlineis
serving sinks or urinals
servingsinksorurinals.
Onshorthorizontaldrainagepipeinstalledataslopeof72degor
lessfromtheverticalline(oratanangleof1/5bend)
Drainage System
DrainageSystem
VENTILATION
VentPipe Apipeoropeningusedforensuringthecirculationofairina
plumbingsystemandforrelievingthenegativepressureexerted
ontrapseals.
p
MainTypes
1.
2.
3.
4.
5.
6
6.
7.
MainSoilandWasteVent
Main
Soil and Waste Vent
MainVent
IndividualVentorBackVent
Unit,Common,orDualVent
ReliefVent
Yoke or By Pass Vent
YokeorByPassVent
CircuitVent
8. LoopedVent
Looped Vent
9. WetVent
10. LocalVent
11. DryVent
12. StackVent
13 VentStack
13.
Vent Stack
Drainage System
DrainageSystem
MainSoilandWasteVent
thebackboneoftheentire
sanitarysystem
ConnectedtotheMainSoil&
Connected to the Main Soil &
WasteStack
Theportionwherewastedoes
The portion where waste does
nottravelthrough
Continuestotheroof;the
portionpenetratingtheroofis
calledtheVentStackThrough
Roof (VSTR)
Roof(VSTR)
Drainage System
DrainageSystem
MainVent
theprincipalarteryofthe
ventingsystemtowhichvent
branches are connected
branchesareconnected.
A.K.A.CollectingVentLine
servesassupporttotheMain
serves as support to the Main
Soil&WasteVent
Drainage System
DrainageSystem
IndividualVentorBackVent
apipeinstalledtoventafixture
trap,thatconnectswiththe
vent system above the fixture
ventsystemabovethefixture
servedorterminatesinthe
open air.
openair.
Sizes:
Lavatories,drinkingfountain
Lavatories
drinking fountain
Sink
Shower,Laundry,Slop,Sink
Water Closet
WaterCloset
::11/2
11/2
:11/2
:1
: 3
:3
Drainage System
DrainageSystem
Unit,CommonorDualVent
Anarrangementofventingso
installedthatoneventpipe
serve two (2) traps
servetwo(2)traps
Drainage System
DrainageSystem
ReliefVent
averticalventlinethatprovides
additionalcirculationofair
between the drainage and vent
betweenthedrainageandvent
systemsortoactasanauxiliary
vent on a specially designed
ventonaspeciallydesigned
systemsuchasayokevent
connectionbetweenthesoil
andventstacks.
Drainage System
DrainageSystem
YokeorBypassVent
Apipeconnectingupwardfrom
asoilorwastestackbelowthe
floor and below horizontal
floorandbelowhorizontal
connectiontoanadjacentvent
stack at a point above the floor
stackatapointabovethefloor
andhigherthanthehighestspill
leveloffixturesforpreventing
pressurechangesinthestacks.
Drainage System
DrainageSystem
CircuitVent
agroupventpipewhichstartsin
frontoftheextreme(highest)
fixtureconnectionona
hori ontal branch and connects
horizontalbranchandconnects
totheventstack.
a.k.a. Loop
LoopVent
Vent
a.k.a.
Servesabatteryoffixtures
Numberofwatercloset Diameterofcircuit
installedinaseries
vent
2
50mm(2)
3 to 6
3to6
75mm (3))
75mm(3
7ormore
100mm(4)
Drainage System
DrainageSystem
LoopedVent
averticalventconnectionona
horizontalsoilorwastepipe
branch at a point downstream of
branchatapointdownstreamof
thelastfixtureconnectionand
turning to a horizontal line
turningtoahorizontalline
abovethehighestoverflowlevel
ofthehighestfixtureconnected
there
Usedinspaceswithoutpartitions
Drainage System
DrainageSystem
WetVent
Thatportionofaventpipe
throughwhichwastewateralso
flows through
flowsthrough.
Drainage System
DrainageSystem
LocalVent
aapipeorshafttoconveyfoulairfromaplumbing
pipe or shaft to convey foul air from a plumbing
fixtureoraroomtotheouterair.
D V t
DryVent
aventthatdoesnotcarryliquidorwaterborne
wastes.
VentStack
theverticalventpipeinstalledprimarilyforprovidingcirculation
ofairtoandfromanypartofthesoil,wasteofthedrainage
f i t
df
t f th
il
t f th d i
system.Theuppermostendabovetheroofhastraditionally
been referred to as Vent Stack Through Roof (VSTR).
beenreferredtoasVentStackThroughRoof(VSTR).
Drainage System
DrainageSystem
VENTSREQUIRED
Eachtrapshallbeprotectedagainstsiphonage andback
pressurethroughventing.
VENTSNOTREQUIRED
On
Onaprimarysettlingtankinterceptorwhichdischarges
a primary settling tank interceptor which discharges
throughahorizontalindirectwastepipeintoasecondary
interceptor.Thesecondaryinterceptorshallbeproperly
trappedandvented.
Trapsservingsinksinanislandbarcounter.Suchsinkshall
discharge by means of an approved indirect waste pipe into a
dischargebymeansofanapprovedindirectwastepipeintoa
floorsinkorotherapprovedtypereceptor.
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
1.DirectSiphonage orSelfSiphonage occursinunventedtrapsthat
serveovalbottomfixturessuchaslavatories.Suchfixturesdischarge
theircontentsrapidlyanddonothavethefinalsmalltrickleofwater
neededtoresealthetrap.Whentheplugiswithdrawn,thewaterflows
outfastandcompletelyfillsthewastepipe.Thewaterdisplacestheair
thatnormallyfillsthewastepipe,loweringtheatmosphericpressure
onthedischargesideofthetrap.Atmosphericpressureonthefixture
sideforcesthewaterthroughthetrap,andthesealislost.
g
p,
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
2.IndirectorMomentumSiphonage causedbyalargedischargeof
waterfromafixtureinstalledoneormorefloorsabovetheaffected
fixture.Thislargedischargetendstoformasluginthestack;andas
thisslugpassesthetakeoffofthefixturebelowit,airispulledoutof
thewastelineonthelowerfixture.Thisreducesthepressureonthe
dischargesideofthetrap.Thereisnoresealuntilthereisadischarge
fromthelowerfixture.
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
3.BackPressure.Backpressurewithinasanitarydrainagesystemis
causedbysimultaneousfixtureusethatovertaxestheplumbing
system,causingapositivepressurethataffectsthewatersealofa
trap.Alargeflowmaycompletelyfillthepipe,causingthe
compressedatmosphericgasestoofferresistancebecausethey
cannotslippasttheflowofthewaterandexhaustataroofterminal.
Asthewaterfalls,thepressureincreasesandcompressestheair,and
thetrapsealblowsoutofthefixture.
p
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
4.CapillaryAction Lossoftrapsealbycapillaryactioniscausedbya
foreignobjectlodgedinthetrap.Theobjectactsasawickandcarries
thewaterfromthetrapovertheoutletsideintothewastepipeuntil
thesealisineffective.Rags,string,lint,andhaircommonlycausethis
problem.
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
Drainage System
DrainageSystem
SANITARYSYSTEMPROBLEMS
Trap Seal Loss
TrapSealLoss
5.Evaporation.Lossoftrapsealfromevaporationonlyoccurswhena
fixtureisnotusedforalongtime.Therateofevaporationinatrap
dependsonthehumidityandtemperatureoftheatmosphere.Atrap
inawarm,dryplacewilllosewatersealbyevaporationmorerapidly
thanoneinacool,dampplace.Ventilationdoesnotsolvethe
problem.Theuseofadeepsealtrapisthebestsolution.One
disadvantageisthatsolidwastescollectinthebottomofthetrapand
clogthepipe
g
pp
Drainage System
DrainageSystem
SepticTank
Awatertightcoveredreceptacledesignedandconstructedtoreceive
thedischargeofsewagefromabuildingsewer,separatesolidsfrom
theliquid,digestorganicmatterandstoredigestedsolidsthrougha
periodofdetention,andallowtheclarifiedliquidstodischargefor
p
,
q
g
finaldisposal
Sludge
g
solidorganicmatterthataredenserthanwaterandsettleatthe
bottomoftheseptictank
Scum
lighterorganicmaterialthatrisetothesurfaceofthewater
Effluent
liquidcontentofsewage
Drainage System
DrainageSystem
SepticTank
Minimum Dimensions:
MinimumDimensions:
Length(L)
Width (W)
Width(W)
Depth(D)
:1500mm
:900mm
900
:1200mm
Drainage System
DrainageSystem
SepticTank
Compartment
Firstcompartment:not lessthan2/3capacityofthetotal
capacityoftank;notlessthan2cumliquidcapacity;shallbe
at least 0 9 m width and 1 5 m long Liquid depth not less
atleast0.9mwidthand1.5mlong;Liquiddepthnotless
than0.6mnormorethan1.8m.
Secondarycompartment:maximumcapacityof1/3total
capacityoftank;minimumof1cumliquidcapacity
Inseptictankshavingover6cumcapacity,thesecondary
compartment should be not less than 1.5 m in length.
compartmentshouldbenotlessthan1.5minlength.
maintainaslopeof1:10atthebottomofthedigestion
chambertocollectthesludgeandmakeiteasilyaccessible
from the manhole
fromthemanhole
Drainage System
DrainageSystem
SepticTank
Manholes
withatleasttwo(2)manholes,508mminmindimension;
oneoverinlet,otheroveroutlet.Whereverfirst
compartment exceeds 3 7 m in length an additional
compartmentexceeds3.7minlength,anadditional
manholerequiredoverthebafflewall.
Sizesofpipeinlet&outlet&theirverticallegs
pp
g
InletandOutletpipes diametersizenotlessthanthe
sewerpipe
Verticallegsofinletandoutletpipes
Vertical legs of inlet and outlet pipes diametersizenot
diameter size not
lessthanthesewerpipenorlessthan104.6mm.
Drainage System
DrainageSystem
SepticTank
Length and location of inlet & outlet
Lengthandlocationofinlet&outlet
Shallextend101.6mmaboveandatleast304.8mmbelowthe
watersurface
Invertoftheinletpipeshallbeatalevelnotlessthan50.8mm
Invert of the inlet pipe shall be at a level not less than 50 8 mm
abovetheinvertoftheoutletpipe.
Airspace
Sidewallsshallextend228.6mmaboveliquiddepth.
Coverofseptictankshallbeatleast50.8mmabovethebackvent
openings
Partition(betweencompartments)
Aninvertedfittingequivalentinsizetothetankinlet,butinnocaseless
than 104 6 mm in diameter shall be installed in the inlet compartment
than104.6mmindiameter,shallbeinstalledintheinletcompartment
sideofthebafflewiththebottomofthefittingplacedmidwayinthe
depthoftheliquid.Woodenbafflesareprohibited.
Drainage System
DrainageSystem
SepticTank
Structure
Shallbecapableofsupportinganearthloadofnotlessthan14.4kPa
Capacity
Thecapacityofseptictanksisdeterminedbythenumberofbedrooms
orapartmentunitsindwellingoccupancies;bytheestimated
waste/sewagedesignflowrateforvariousbuildingoccupancies;orby
/
g
g
g
p
;
y
thenumberoffixtureunitsofallplumbingfixtures;whicheverisgreater.
Thecapacityofanyoneseptictankanditsdrainagesystemshallalsobe
limited by the soil structure classification in its drainage field
limitedbythesoilstructureclassificationinitsdrainagefield.
Location
Shouldnotbelocatedunderneaththehouse
Atleast15metersfromthewaterdistributionsystem
l
f
h
d
b
Drainage System
DrainageSystem
SepticTank
Suggested Size
NumberofPerson Served
Depth
Width
Length
10
1.20
0.90
1.80
15
1.20
1.10
2.20
20
1.20
1.25
2.50
25
1.20
1.40
2.80
30
1.30
1.50
3.00
35
1 30
1.30
1 60
1.60
3 20
3.20
40
1.40
1.65
3.30
45
1.40
1.75
3.50
50
1.50
1.80
3.60
Drainage System
DrainageSystem
SepticTank
Suggested Size
NumberofPerson Served
Depth
Width
Length
60
1.50
1.95
3.90
70
1.50
2.00
4.00
80
1.60
2.20
4.40
90
1.80
2.30
4.60
100
1.80
2.50
5.00
Drainage System
DrainageSystem
SepticTank
Technical Data in Determining Volume of Tank
1.
2.
3
3.
4.
5.
Min.Width:0.90m
MinLength:1.50m
Min Depth: 1 20m
MinDepth:1.20m
ForResidential:allocate0.14to0.17cumofliquidperperson
ForSchoolandindustrialestablishment:Volumeshouldnotbe
l
lessthan0.057cumnormorethan0.086cumperperson
h
h
Plumbing Fixtures
Plumbing Fixtures
Fixtures
receptaclesattachedtoaplumbingsystemotherthanatrapinwhich
waterorwastemaybecollectedorretainedforultimatedischargeinto
theplumbingsystem.
Commontypesofplumbingfixturesusedinresidences
f l b f
d
d
1.Watercloset
2.Lavatory
3.Kitchensink
4 Ui l
4.Urinal
5.Bidet
6. Bath tub
6.Bathtub
Plumbing Fixtures
WaterCloset
Aplumbingfixtureusedtoreceivehumanexcrementalandto
dischargeitthroughawastepipe,usingwaterasaconveyingmedium.
Waterclosetsareclassifiedaccordingto design,make,flushing
mechanism,shapeandinstallation.
,
p
TypesofWaterClosetastoDesign
1.Siphonwashdown
p
2.Siphonjet
3.SiphonVortex
4.Reversetrap
Plumbing Fixtures
WaterCloset
Fixture
DFU
Vent
Soil pipe
PrivateUse
76mm(3)
100mm (4)
PublicUse
76mm(3)
100mm (4)
Fixture
WSFU
Water SupplyPipe
12mm(1/2)
Flush
l h Tank
k Public
bl
12mm(1/2)
( / )
FlushValve Private
25mm (1)
10
25mm (1
(1))
Plumbing Fixtures
Siphonwashdown
Theleastexpensivebutthenoisiest;onlysmallamountofstanding
watersusceptibletofouling,stainingandcontamination.Itis
mechanicallysatisfactoryandislowerinprice.Hence,itiswidelyused
andentirelyacceptablewherepriceisthemainconsideration.
y
p
p
Plumbing Fixtures
SiphonJet
Thejetbeingsubmergedintroducesitswaterunderwatersothatits
operationisentirelymuffled.Ithasalargeamountofstandingwaterto
preventfouling.Itismechanicallyefficientbutexpensive.
Plumbing Fixtures
SiphonVortex
thistypeofbowldevelopsitsflushingactionthroughthewater
enteringthroughdiagonalholesaroundtherimwhichcreatesa
swirlingactionwhichformsavortexinthecenter.Itisconsideredtobe
themostquiet,mostefficientandmostsanitarywatercloset.
q
,
y
Plumbing Fixtures
ReverseTrap
thetrapwaylocatedattherearofthewatercloseteliminatedthe
bulgeatthefront.Thedesignandappearanceofthebowlplusitslarge
waterareaandquietnessinoperation,makeitdesirablethansiphon
washdown.
Plumbing Fixtures
TypesofWaterClosetastoMake
1.
1
2.
3.
4.
OnePiece
One
Piece
CloseCoupled
Pail flush
Pailflush
SquatBowl
Plumbing Fixtures
OnePiece
Thewaterclosetfixtureismanufacturedwiththe
bowlandtheflushtankmoldedintoasingleunit.Usuallyusedin
tandemwiththebidet.
Plumbing Fixtures
PailFlush
awaterclosetcomprisingonlyofabowlwithoutaflushtank.Flushing
actionisobtainedonlythroughwaterpouredfromapailorbucket.
Thisisusedinareaswhererunningwatersystemsarenotavailable.
Plumbing Fixtures
SquatBowl
AwaterclosetthatisotherwiseknownasEastern
typesincetheuserassumesasquattingpositionratherthanasitting
position
Plumbing Fixtures
TypesofWaterClosetastoFlushingMechanism
Flush Tank
FlushTank
holdsasupplyofwaterforflushinga
fixturesuchasthewatercloset.Ithasa
capacityof5to6gallons
i
f
ll
FlushValve(Flushometer)
holdsasupplyofwaterforflushinga
fixture such as the water closet It has a
fixturesuchasthewatercloset.Ithasa
capacityof5to6gallons
Plumbing Fixtures
TypesofWaterClosetastoShape
Round Front
RoundFront
intendedforinstallationonalimited
space
ElongatedFront
ismorecomfortablebutoccupiesa
largerspace
Plumbing Fixtures
TypesofWaterClosetastoInstallation
Free Standing (Floor Mounted)
FreeStanding(FloorMounted)
WallHung(WallMounted)
Plumbing Fixtures
MinimumWaterClosetClearances
Plumbing Fixtures
Lavatory
afixturedesignedforthewashingofthehandsorface.Itisalsoknown
aswashbasin.
TypesofLavatory
1.
2.
3
3.
4.
5
5.
Wallhung
Pedestal
C
CounterTypeLavatory
t T
L t
O
OverCounterorUnderCounter
C
t
U d C
t
SurfaceMountedLavatory
One Piece Lavatory
OnePieceLavatory
Plumbing Fixtures
Lavatory
Fixture
DFU
Vent
Soil pipe
Sets
38mm(11/2)
38mm(11/2)
Single
38mm(11/2)
38mm(11/2)
Fixture
WSFU
Water SupplyPipe
Private
12mm(1/2)
Public
bl
12mm(1/2)
( / )
Plumbing Fixtures
TypesofLavatory
Wall Hung Lavatory
WallHungLavatory
Plumbing Fixtures
TypesofLavatory
Pedestal Lavatory
PedestalLavatory
Plumbing Fixtures
TypesofLavatory
CounterTypeLavatory
Counter
Type Lavatory
Undercounter
Overcounter
Plumbing Fixtures
TypesofLavatory
Surface Mounted Lavatory
SurfaceMountedLavatory
Plumbing Fixtures
MinimumLavatoryClearance
Plumbing Fixtures
Bidet
aplumbingfixtureusedforwashingthemiddlepartofthebody,
especiallythegenitals.ItisalsoknownastheSitz Bath
Plumbing Fixtures
Bidet
Fixture
Bidet
Fixture
DFU
Vent
Soil pipe
38mm(11/2)
51mm(2)
WSFU
Water SupplyPipe
Private
12mm(1/2)
Public
12mm(1/2)
Plumbing Fixtures
Bathtub
atubeforbathing,usuallyafixedplumbinginstallationdesignedfor
oneperson.Itisavailableinleftoutletandrightoutlet
Requirements for whirlpool
bathtubs
1. Provideremovableaccesspanelto
thepump.
p p
2. Locatethecirculationpumpabove
thecrownweirofthetrap.
3. Thepumpandthecirculation
pipingshallbeselfdrainingto
minimizewaterretention.
4. Suctionfittingsonwhirlpool
bathtubsshallcomplywiththe
listedstandards
Plumbing Fixtures
Bathtub
Fixture
Bathtub
Fixture
DFU
Vent
Soil pipe
38mm(11/2)
38mm(11/2)
WSFU
Water SupplyPipe
Private
12mm(1/2)
Public
bl
12mm(1/2)
( / )
Plumbing Fixtures
Urinal
Asanitaryfixtureequippedwithawatersupplyanddrainforflushing
awayurine
TypesofUrinal
1.
2.
3
3.
4.
WallhungUrinal
PedestalUrinal
St ll U i l
StallUrinal
ThroughUrinal
Plumbing Fixtures
Urinal
Fixture
DFU
Vent
Soil pipe
Wall Mounted
38mm(11/2)
51mm(2)
Stall
38mm(11/2)
51mm(2)
TrapArm
38mm(11/2)
51mm(2)
Fixture
WSFU
Water SupplyPipe
WallMounted
19mm(3/4)
Stall
19mm(3/4)
Plumbing Fixtures
WallHungUrinal
Plumbing Fixtures
PedestalUrinal
Plumbing Fixtures
StallUrinal
Plumbing Fixtures
ThroughUrinal
Plumbing Fixtures
MinimumUrinalClearance
Plumbing Fixtures
OtherFixtureUnits
Sinks
Fixture
DFU
Vent
Soil pipe
KitchenSink(residential)
38mm(11/2)
51mm(2)
Bar Sink(commercial)
38mm(11/2)
51mm(2)
Sinkk (Commercial,
Si
(C
i l
industrial,Institutional)
38
38mm(11/2)
(1 1/2)
51
51mm(2)
(2)
Sink(clinic)FlushingRim
38mm(11/2)
76mm(3)
SlopSink
38mm(11/2)
51mm (2)
LaundryTub
38mm(11/2)
38mm(11/2)
Plumbing Fixtures
OtherFixtureUnits
Sinks
Fixture
WSFU
Water SupplyPipe
Kit h Si k
KitchenSink
12
12mm
(1/2)
ScullerySink
19mm(3/4)
Slop Sink
SlopSink
10
12mm (1/2
(1/2))
LaundryTub
12mm (1/2)
BarSink
12mm (1/2)
Plumbing Fixtures
OtherFixtureUnits
Drinking Fountain
DrinkingFountain
Fixture
DFU
Vent
Soil pipe
Private
32mm(11/4)
32mm(11/4)
Public
32mm(11/4)
32mm(11/4)
Fixture
WSFU
Water SupplyPipe
Pi t
Private
1( hf
1(eachfaucet)
t)
12
12mm
(1/2)
Public
2(eachfaucet)
12mm (1/2)
Plumbing Fixtures
OtherFixtureUnits
Shower Bath
ShowerBath
Fixture
DFU
Vent
Soil pipe
Private
38mm(11/2)
51mm(2)
Public
38mm(11/2)
51mm(2)
Fixture
WSFU
Water SupplyPipe
Pi t
Private
2 ( h h d)
2(eachhead)
12
12mm
(1/2)
Public
4(eachhead)
12mm (1/2)
Plumbing Fixtures
OtherFixtureUnits
Floor Drain
FloorDrain
Fixture
DFU
Vent
Soil pipe
Private
38mm(11/2)
51mm(2)
Public
38mm(11/2)
51mm(2)
HoseBibb
Fixture
WSFU
Water SupplyPipe
Private
12mm (1/2)
Public
12mm (1/2)
StormWaterSystem
SizeofStormDrain
Thefollowingfactorsshouldbeconsideredwhendeterminingthesize
of the storm drain:
ofthestormdrain:
1.Gaugingtherainfall,constant,shortdurationorheavyshower
2.Thevaryingroofareaanditsslopeincludingthedistanceofwater
travelbeforeitreachestheconductorsordownspoutsoftheroof
lb f
i
h h
d
d
f h
f
3.Waterdrainisfasteronhigherpitchedroofshence,requiresalarger
drainagepipethanthatofaflatroof
4 Th h i h f h b ildi
4.Theheightofthebuildingcontributestothehighvelocityofwaterin
ib
h hi h l i
f
i
theverticalconductorandacceleratetheflowofwaterenteringthe
stormdrain.
Maximum obtainedroofarea(sqm)
obtained roof area (sqm)
(mm)
(in)
2%slope
3%Slope
4%Slope
75
114
142
170
100
242
315
388
125
438
566
694
150
700
903
1105
1888
2313
200
8
8
1463
3309
4055
250
10
2563
5290
6480
300
12
4100
350
14
5576
7203
8830
GutterTop
G
tt T
Dimension
(mm)
Downspoutt orRoof
D
R f
LeaderDiameter
(mm)
1 to10
75
38
11to25
100
50
26 to 75
26to75
100
75
76to165
125
90
166to335
150
100
336to510
200
125
511to900
250
150