Chapter-4
GENERAL
This part sets out the standard space requirements of various parts of a building and those of
light and ventilation. Some of these items depend on the number of persons who would
normally occupy the building, for which the occupant load should be worked out from table
hereunder:
Table 4.1
Sl.
No.
1
2
3
4
5
6
7
8
*
Occupant Load
Type of Occupancy
Residential
Educational
Institutional
Assembly
(a) with fixed or loose seats and dance floor
(b) without seating facilities including
dining rooms
Mercantile
(a) street floor and sales basement
(b) upper sale floor
Business and industrial
Storage
Hazardous
The occupant load in dormitory portions of homes for the aged, orphanages or mental hospitals etc.
where sleeping accommodation is provided shall be calculated at not less than 13.3 persons per 100
sq.m.
**
The plinth or covered area shall include, in addition to the main assembly room or space, any
occupied connecting room or space in the same storey or in the storeys above or below where entrance
is common to such rooms and space and the area available for use by the occupants of the assembly
place. No deduction shall be made in the plinth/covered area for corridors, closets and other subdivisions; that area shall include all space serving the particular assembly occupancy.
4.2
58
Model Building-Bye-laws
Chapter-4
4.2.1
Main Building
The plinth or any part of a building or outhouse shall be so located with respect to average
road level from site so that adequate drainage of the site is assured but at a not height less
than 45 cm.
4.2.2
These shall be raised at least 15 cm. above the surrounding ground level and shall
satisfactorily drained.
4.2.3
Component of
Building
Habitable Room
Kitchen
Pantry
Bathroom
W.C.
Store
Projections
9
10
Canopy
Garage
59
Model Building-Bye-laws
Chapter-4
Sl.
No.
Component of
Building
11
12
Passage
Doorways
rooms
14
for
0.75 m.
2.00 m
0.90 m.
Notes
1.
Provided that the minimum clear head way under any beam shall be not less than 2.4 m.
2.
Maximum height permissible for all the components of the building mentioned above is 4 m.
4.3
GROUP HOUSING
a)
b)
c)
All open spaces provided either in interior or exterior shall be kept free from
any erections thereon and shall open to the sky. Nothing except cornice,
chhajja or weather shade (not more than 0.75 m. wide) shall overhang or
project over the said open space so as to reduce the width to less than
minimum required.
Note:
Such projections shall not be allowed at height less than 2.2 m. from the corresponding finished floor
level:
ii)
One canopy per block on the ground floor not exceeding 4.5 m. in length and
2.4 m. in width
iii)
Balcony at roof slab level of 1.2 m. width and area not exceeding 3.5 sq m.
per bedroom but not exceeding 3 in number per flat.
60
Model Building-Bye-laws
Chapter-4
iv)
Balcony having entrance from the toilet/bathroom and width as 1.2 m. for
drying clothes.
61
Model Building-Bye-laws