Technical Data
Daikin Altherma low temperature split
EEDEN12-725
EBHQ-BV3
TABLE OF CONTENTS
EBHQ-BV3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Options
............................................................... 6
Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Heating Capacity Tables
Cooling Capacity Tables
10
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
14
14
Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
Operation Range
11
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Piping Diagrams
............................................. 9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensional Drawings
3
5
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Hydraulic performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Static Pressure Drop Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1
h t l A 3 g Vn nB i i - k tQ i aH aBe DHE
Features
Single phase reverisble monobloc
Eco-label certified
Specifications
Cooling capacity
Min.
kW
EBHQ006BV3
EBHQ008BV3
Nom.
kW
Max.
kW
Min.
kW
1
2
Nom.
kW
Max.
kW
Capacity control
Method
Power input
Cooling
Nom.
kW
Heating
Nom.
kW
COP
EER
Casing
Colour
Dimensions
Unit
Inverter controlled
Packed unit
Height
mm
805
Width
mm
1,190
Depth
mm
360
Height
mm
915
Width
mm
1,265
mm
442
Depth
Packing
Unit
kg
95
Packed unit
kg
104
Operation weight
kg
Material
99
Wood / Carton / EPS
Weight
Heat exchanger
Length
Rows
Stages
mm
845
mm
1.8
Quantity
32
Tube type
8 Hi-XA
Fin
Type
WF fin
Treatment
Type
Water cooled
Quantity
Model
RS 25/7 3 PL 130 3
Nr of speeds
Expansion vessel
Fan
Heating
kPa
46.1 (4)
Cooling
kPa
49.7 (5)
31.5 (4)
45.8 (5)
Power input
130
Volume
bar
Pre pressure
bar
1.0
Heater
50
Type
Propeller fan
Quantity
Discharge direction
Fan motor
Horizontal
Quantity
Output
Compressor
kg
Quantity
Fin pitch
Pump
Material
Weight
1
W
53
Quantity
Model
2YC63BXD#C
Type
Output
Starting method
1,920
Inverter driven
Specifications
EBHQ006BV3
Heating
Ambien Min.
t
Max.
Water
side
Cooling
CWB
25
Min.
15 (6)
Max.
50 (6)
CDB
10
CDB
43
Water
side
Min.
Max.
22
CDB
-15
CDB
35
Ambien Min.
t
Max.
Min.
25
Max.
80
Type
Brazed plate
Quantity
Water volume
0.67
Heating Nom.
l/min
17.2 (4)
25.4 (4)
Cooling Nom.
l/min
14.7 (5)
17.4 (5)
Min.
l/min
12
Insulation material
Refrigerant
Foamed polyurethane
Type
R-410A
Charge
kg
1.7
Control
Circuits
Refrigerant oil
Quantity
Type
FVC50K
Charged volume
Sound power level
Sound pressure level
0.75
Heating
Nom.
dBA
61
Cooling
Nom.
dBA
Heating
Nom.
dBA
48
Cooling
Nom.
dBA
48
62
63
49
50
Defrost method
Reversed cycle
Defrost control
Water filter
mm
Material
Water circuit
inch
G 1" (male)
Piping
inch
5/4"
10
Piping length
Max.
Level difference
Max.
OU Tank
bar
Manometer
3
Yes
Yes
Yes
Yes
1
Brass
Safety valve
Safety devices
EBHQ008BV3
-15
Ambien Min.
t
Max.
Water
side
Water side Heat
exchanger
CWB
Item
01
5.5 (7)
10 (8.0)
Fan motor thermal protection
02
Fuse
03
04
Flowswitch
05
Specifications
EBHQ006BV3
Name
Phase
Voltage range
Current
Hz
50
Voltage
230
Min.
-10
Max.
10
Maximu Heating A
m
Cooling A
running
current
Recommended
fuses
Zmax
1~
Frequency
18
11
11
20
Text
Notes
16.25
Starting Heating A
current Cooling A
Current
EBHQ008BV3
V3
0.42
EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes,
voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated 75A
Notes
(1) EN14511: cooling Ta 35C - LWE 18C (Dt = 5C); heating Ta DB/WB 7C/6C - LWC 35C (Dt = 5C)
(2) EN14511: cooling Ta 35C - LWE 7C (Dt = 5C); heating Ta DB/WB 7C/6C - LWC 45C (Dt = 5C )
(3) The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to
sound spectrum drawing for more information.
(4) Condition: Ta DB/WB 7C/6C - LWC 35C (DT = 5C)
(5) Condition: Ta 35C - LWE 7C ( DT = 5C)
(6) 15C-25C: BUH only, no heat pump operation = during commisioning
(7) Including piping + PHE; excluding expansion vessel
(8) Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra
water volume might be required. Refer to operation range for more info.
(9) See separate drawing for operation range
(10) The 3-way valve should be mounted as close as possible to the outdoor unit
(11) Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents
produced by equipment connected to public low-voltage systems with input current \>16A and 75A per phase
(12) Wiring connections: cf. connection diagram for full wiring overview; Select diameter and type according to local regulations; For more details on voltage range and current cf.
EBHQ installation manual
(13) Power supply compressor compartment is for compressor, fan, pump and controller
(14) In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys
(system impedance) Zmax
(15) EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for
equipment with rated 75A
Options
3-1
Options
EBHQ006-008BV3
EKMBUH
EKCBH/X008
Factory mounted optional equipment for EKMBUHB*6V3
1
3
Reference
6V3
Description
Back-up heater 6kW1~230V
EKMBUHB*6V3
EKCBH008BAV3
(1)
(1)
(1)
EKCBX008BAV3
(1)
(1)
(1)
EBHQ006B*V3*
(1)
EBHQ008B*V3*
(1)
EKCBH008BBV3
(1)
(1)
EKCBX008BBV3
(1)
(1)
Description
Heating only model *KCBH008B*#
Reversible model *KCBX008B*#
NOTES
#
V3
V3
EKHWS150*3V3
EKHWS200*3V3
EKHWS300*3V3
EKHWS200*3Z2
EKHWS300*3Z2
EKHWSU150*3V3
EKHWSU200*3V3
EKHWSU300*3V3
EKHWE150*3V3
EKHWET150*3V3
EKHWE200*3V3
EKHWE300*3V3
EKHWE200*3Z2
EKHWE300*3Z2
EKRP1HBA
EKRTWA
EKRTR1
EKRTETS
EKSOLHWAV1
EKSR3PA
Solar kit - Connection kit between solar panel, monobloc & tank
Solar kit - Control panel
1. Obligatory combination
2. Heater tape that can be fixed on the bottom plate to prevent excessive ice formation.
3. Address card that provides two additional output connections (remote alarm and remote ON/
OFF signalisation). In *KSOLHWAV1, the same digital I/O PCB as for *KRP1HB is already
included.
4. EKRTETS can only be used in combination withe EKRTR1
5. For further options on tanks (wall mounting bracket, valve kits, ...) see combination table of
tanks.
Remark: Other combinations than mantioned in this option TW are not guaranteed.
3TW60419-2
(%+4%9
(.0%8+
(.&%+;
.LWDYDLODELOLW\IRU
.+:
5HIHUHQFH
'HVFULSWLRQ
.+:(79=
.+:69=
.+:689
$
$
$
$% $% $%
$
$
$
%
%
%
.8+:$
.8+:%
2SWLRQNLWIRU8. .+:68a9
.8+::%
2SWLRQNLWIRU8. .+:68a9
.62/+:$9
6RODUNLW
.:%6::
5HPDUN2WKHUFRPELQDWLRQVDUHQRWJXDUDQWHHG
127(6
.LWWREHPRXQWHGRQGRPHVWLFKRWZDWHUWDQNWKDWSURYLGHVFRQQHFWLRQWRVRODUSDQHOVIRUDGGLWLRQDOZDWHUKHDWLQJ
,ILQVWDOODWLRQRQWDQN$YHUVLRQERWKNLWVDUHUHTXLUHG
.LWLVRQO\QHFHVVDU\ZKHQLQVWDOOLQJ
.62/+:$9RQD8.WDQN%VHULHV
.+:68%9
.8+:%
.8+:$ZD\YDOYHDQGZD\YDOYHDFFHVVRULHV
.8+::% ZD\YDOYHDQGZD\YDOYHDFFHVVRULHV
7:
Options
3-1
Options
EBHQ006-008BV3
EKMBUH
EKCBH/X008
Bivalent system
Space heating with an auxiliary boiler (alternating operation)
CAUTION
Be sure that the boiler and the integration of the boiler in the system is
in accordance with relevant local laws and regulations.
Always install a 3-way valve, even if no domestic hot water tank is
installed. This to ensure that the freeze protection function can operate
when the boiler is active.
1
2
3
4
5
6
7
9
10
11
14
15
16
17
FHL 1 ... 3
C
I
1 Motorised 3-way valve
2 Boiler
Outdoor unit
Heat exchanger
Pump
Shut-off valve
Heater kit
Collector (eld supply)
Motorised 3-way valve
(delivered with the domestic hot water tank)
Booster heater
Heat exchanger coil
Domestic hot water tank (optional)
Boiler (eld supply)
Aquastat valve (eld supply)
Shut-off valve (eld supply)
Non-return valve (eld supply)
Floor heating loop (eld supply)
Control box
User interface
EKCB(H/X)*X2M
Boiler thermostat
input
K1A
K2A
3TW60419-3
Options
3-1
Options
Operation
EBHQ006-008BV3
EKMBUH
EKCBH/X008
Conguration A
When the room thermostat requests heating, either the EBHQ* unit or the
boiler starts operating, depending on the position of the auxiliary contact (A).
Conguration B
When the room thermostat requests heating, either the EBHQ* unit or the
boiler starts operating, depending on the outdoor temperature (status of
permission signal for the auxiliary boiler).
When the permission is given towards the boiler, the space heating operation
by the EBHQ* unit will be automatically switched off.
Boiler thermostat
input
CAUTION
Com
K1A
KCR
Make sure that return water to the EBHQ* heat exchanger never exceeds
55C.
For this reason, never put the target leaving water temperature set point
on the boiler controller above 55C and install an aquastat(a) valve in the
return water ow of the EBHQ* unit.
Make sure that the non-return valves (eld supply) are correctly installed
in the system.
Make sure that the room thermostat (th) is not frequently turned ON/OFF.
Daikin shall not be held liable for any damage resulting from failure to
observe this rule.
NOTES
Make sure to congure the DIP switch SS2-3 on the PCB of the EKCB(H/X)* switch box correctly.
For conguration B: Make sure to congure the eld settings correctly.
Conguration A
Make sure that auxiliary contact (A) has sufcient differential or time delay so as to avoid frequent changeover between the EBHQ* unit and the boiler. If the
auxiliary contact (A) is an outdoor temperature thermostat, make sure to install the thermostat in the shade, so that it is not inuenced or turned ON/OFF by
the sun.
Conguration B
Make sure that the bivalent hysteresis has sufcient differential to avoid frequent changeover between the EBHQ* unit and the boiler. As the outdoor
temperature is measured via the outdoor unit air thermistor, make sure to install the outdoor unit in the shade, so that it is not inuenced by the sun.
Frequent switching may cause corrosion of the boiler in an early stage. Contact the manufacturer of the boiler.
During heating operation of the EBHQ* unit, the unit will operate so as to achieve the target leaving water temperature as set on the user interface. When
weather dependent operation is active, the water temperature is determined automatically depending on the outdoor temperature.
During heating operation of the boiler, the boiler will operate so as to achieve the target leaving water temperature as set on the boiler controller.
Never set the target leaving water temperature set point on the boiler controller above 55C.
Make sure to only have 1 expansion vessel in the water circuit. An expansion vessel is already premounted in the Daikin unit.
(a)
The aquastat valve must be set for 55C and must operate to close the return water ow to the unit when the measured temperature exceeds 55C. When the temperature
drops to a lower level, the aquastat valve must operate to open the return water ow to the EBHQ unit again.
3TW60419-3
Capacity tables
4-1
3
1
4
Capacity tables
4-2
1
4
10
Dimensional drawings
5-1
Dimensional Drawings
(%+4%9
0$/(
0LQLPXPVHUYLFHDQGLQVWDOODWLRQVSDFH
VFDOH
)(0$/(
1
5
QRWHZDOOKHLJKWRQDLURXWOHWVLGHPXVWEHOHVVWKDQ
6FDOH
[KROHVIRUDQFKRUEROWV
0RU0
[GUDLQKROH
1U
1DPH
:DWHULQOHWPDOH
:DWHURXWOHWPDOH
3RZHUVXSSO\LQWDNH
&RPPXQLFDWLRQFDEOHLQWDNH
7KHUPLVWRUFDEOHLQWDNH
'UDLQDQGOOYDOYH
%ORZRIIYDOYH
3XPS
([SDQVLRQYHVVHO
:DWHUOWHU
$LUSXUJH
6ZLWFKER[
2XWGRRUDLUWKHUPLVWRU
VKXWRIIYDOYHVGHOLYHUHGZLWKXQLW
&HQWHURIJUDYLW\
7:
11
Piping diagrams
6-1
Piping Diagrams
EBHQ006-008BV3
EKMBUH
EKCB(H/X)008BBV3
Outdoor unit
EBHQ*BAV3
Expansion
vessel
BUH-KIT
EKMBUHBA6V3
Evaporator
Air purge
Pressure
gauge
Safety valve
Air purge
Condensor
Field installation
R12T
Blow off
Refrigerant side
R11T
Pump
Refr. out
Water outlet
Electric heater
body
Thermistor
R11T
R12T
R13T
R14T
Refr. in
Drain port
Plate heat
exchanger
Description
Outlet water heat exchanger
thermistor
Outlet water backup heater thermistor
Refrigerant liquid side thermistor
Inlet water thermistor
Flow switch
Field installation
Shut off valve
Refr. in
Filter
Water inlet
Refr. out
Drain port
Cooling (EBHQ)
Cooling (E(B/D)HQ)
NOTES
: Check valve,
12
: Flare connection,
: Screw connection,
: Flange connection,
: Pinched pipe,
: Spinned pipe
3TW60415-1A
Wiring diagrams
7-1
1
7
13
8-1
Electrical connection diagram, only valid for units in combination with EKCB(H/X)*BB*-units
Standard parts
Power supply
1
8
Outdoor unit
3 core
Only for benet kWh rate power supply installation unit benet
kWh power supply: 230V + earth
3 core
L-N-earth
L-N-earth
230V
Normal kWh rate power supply for indoor unit: 230V + earth
3 core
2 core
earth 1-2-3
2 core
Benet kWh rate power supply contact
(Common)
(BPH Control)
(exp. vessel heater)
(pump)
Bottom plate
heater
Optional parts
signal
signal
8 core
3 core
4 core
4 core
2 core
Optional parts
earth 1-2-3
signal
30-31 earth
Domestic hot
water tank
BUH control
L1-L2-earth or L-N-earth
2-way valve
Field supply
Indoor unit
2 core
Alarm indication
Alarm output
clixon
2 core
Power supply
booster heater
5 core
Cooling/heating
on/off output
1-2-earth
Cooling/heating
On/off indication
2 core
BSK: 1-2 Solar interlock
Solar input
230V or 400V
Q2L - Clixon
booster heater
Changeover to
boiler output
2 core
R5T - Thermistor
water temperature
signal
solar pump
Q*L
clixon
signal
2 core
NO valve:
NC valve:
Room thermostat
3-way valve
M3S (when *KHW is installed) selection
domestic hot water-oorheating
Boiler
3 core
2-way valve
M2S (*KCBX* units) for
cooling mode
Optional parts
Possibility 1
Possibility 2
2 core
R2T:
External sensor
(oor or ambient)
signal
user interface
signal
NOTES
1. Keep mimimum distance between signal cable and power cable >5cm
2. Field wiring:
: Field supply,
: Delivered with unit / option
14
3TW60416-2A
Sound data
9-1
EBHQ006-008BV3
EBHQ006 *
Heating
EBHQ008*
Heating
1
Sound pressure level (dB)
NOTES
1
2
3
4
Location of microphone
3TW60417-1
15
Sound data
9-2
EBHQ006-008BV3
EBHQ006 *
Cooling
EBHQ008*
Cooling
1
Sound pressure level (dB)
NOTES
1
2
3
4
Location of microphone
16
3TW60417-1
10
Operation range
10 - 1 Operation Range
outdoor temp. (CDB)
EBHQ-BV3
1
10
leaving evaporator
water temperature (C)
leaving evaporator
water temperature (C)
EBHQ-BV3
4TW60413-1A
EBHQ006/008BAV3 + EKCBX008BBV3
PULL DOWN AREA
leaving evaporator
water temperature (C)
EBHQ006/008BAV3 + EKCB(H/X)008BBV3
ONLY DURING START-UP
leaving condensor
water temperature (C)
EBHQ006/008BAV3 + EKCB(H/X)008BBV3
ONLY BOOSTER HEATER OPERATION
4TW60413-1A
17
11
Hydraulic performance
EBHQ006-008BV3
ESP [kPa]
11
Flow [l/min]
III high speed
II medium speed
I low speed
NOTES
1
2
Selecting a flow outside the curves can cause damage to or malfunctioning of the unit.
See also minimum and maximum allowed water flowrange in the technical specifications.
Water quality must be according to EN directive EC 98/83 EC
4TW60419-1
18
The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.
has compiled the content of this leaflet to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of i ts content and the products
and se rvices pr esented ther ein. S pecifications are su bject t o c hange
without prior notice. Daikin Europe N.V. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the us e and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
Daikin E urope N.V. participates in the Eu rovent Certification programme for Air conditioners ( AC), Li quid Chil ling P ackages
(LCP) and Fan coil units (FCU), Check ongoing validity of c ertificate online: www.eurovent-certification.com o
ru
sing:
www.certiflash.com
BARCODE
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende