Heating

Technical Data
Daikin Altherma low temperature split

EEDEN12-725

EBHQ-BV3

Daikin Altherma low temperature split EBHQ-BV3

TABLE OF CONTENTS
EBHQ-BV3

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Options

............................................................... 6

Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Heating Capacity Tables
Cooling Capacity Tables

10

Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

External connection diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

External Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

Operation Range

11

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Wiring Diagrams - Single Phase

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Piping Diagrams

............................................. 9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensional Drawings

3
5

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Hydraulic performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Static Pressure Drop Unit

Heating Daikin Altherma low temperature split

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Daikin Altherma low temperature split EBHQ-BV3

1
h t l A 3 g Vn nB i i - k tQ i aH aBe DHE

Features
Single phase reverisble monobloc

Eco-label certified

Energy efficient heating and cooling system based on air to water


heat pump technology

Built-in electric back-up heater as additional heating during extremely


cold outdoor temperature

H2O piping between outdoor unit and indoor heat emitters

Inverter controlled swing compressor

Low energy bills and low CO2 emissions

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

Specifications

2-1 Technical Specifications


Heating capacity

Cooling capacity

Min.

kW

EBHQ006BV3

EBHQ008BV3

4.36 (1) / 3.87 (2)

4.36 (1) / 3.87 (2)

Nom.

kW

6.00 (1) / 5.58 (2)

8.85 (1) / 8.15 (2)

Max.

kW

7.45 (1) / 6.68 (2)

9.58 (1) / 8.76 (2)

Min.

kW

4.82 (1) / 3.67 (2)

4.82 (1) / 3.67 (2)

1
2

Nom.

kW

7.00 (1) / 5.12 (2)

8.37 (1) / 6.08 (2)

Max.

kW

7.20 (1) / 5.12 (2)

8.91 (1) / 7.10 (2)

Capacity control

Method

Power input

Cooling

Nom.

kW

2.20 (1) / 2.16 (2)

2.97 (1) / 2.75 (2)

Heating

Nom.

kW

1.41 (1) / 1.79 (2)

2.21 (1) / 2.72 (2)

COP

4.26 (1) / 3.11 (2)

4.00 (1) / 3.00 (2)

EER

3.18 (1) / 2.37 (2)

Casing

Colour

Dimensions

Unit

Inverter controlled

Painted galvanized steel plate

Packed unit

Height

mm

805

Width

mm

1,190

Depth

mm

360

Height

mm

915

Width

mm

1,265

mm

442

Depth

Packing

Unit

kg

95

Packed unit

kg

104

Operation weight

kg

Material

99
Wood / Carton / EPS

Weight
Heat exchanger

Length
Rows
Stages

mm

845

mm

1.8

Quantity

32

Tube type

8 Hi-XA

Fin

Type

WF fin

Treatment

Anti-corrosion treatment (PE)

Type

Water cooled

Quantity

Model

RS 25/7 3 PL 130 3

Nr of speeds

Nominal ESP unit

Expansion vessel

Fan

Heating

kPa

46.1 (4)

Cooling

kPa

49.7 (5)

31.5 (4)
45.8 (5)

Power input

130

Volume

Max. water pressure

bar

Pre pressure

bar

1.0

Heater

50

Type

Propeller fan

Quantity

Discharge direction
Fan motor

Horizontal

Quantity
Output

Compressor

Wood / Carton / EPS

kg
Quantity

Fin pitch

Pump

2.82 (1) / 2.21 (2)


Ivory white

Material

Weight

1
W

53

Quantity

Model

2YC63BXD#C

Type
Output

Hermetically sealed swing compressor


W

Starting method

1,920
Inverter driven

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

Specifications

2-1 Technical Specifications


Operation range

EBHQ006BV3

Heating

Ambien Min.
t
Max.
Water
side

Cooling

Domestic hot water

CWB

25

Min.

15 (6)

Max.

50 (6)

CDB

10

CDB

43

Water
side

Min.

Max.

22

CDB

-15

CDB

35

Ambien Min.
t
Max.
Min.

25

Max.

80

Type

Brazed plate

Quantity

Water volume

Water flow rate

0.67

Heating Nom.

l/min

17.2 (4)

25.4 (4)

Cooling Nom.

l/min

14.7 (5)

17.4 (5)

Min.

l/min

12

Insulation material
Refrigerant

Foamed polyurethane

Type

R-410A

Charge

kg

1.7

Control

Expansion valve (electronic type)

Circuits
Refrigerant oil

Quantity

Type

FVC50K

Charged volume
Sound power level
Sound pressure level

0.75

Heating

Nom.

dBA

61

Cooling

Nom.

dBA

Heating

Nom.

dBA

48

Cooling

Nom.

dBA

48

62
63
49
50

Defrost method

Reversed cycle

Defrost control
Water filter

Sensor for outdoor heat exchanger temperature


Diameter perforations

mm

Material
Water circuit

Piping connections diameter

inch

G 1" (male)

Piping

inch

5/4"

10

Piping length

Max.

Level difference

Max.

OU Tank

bar

Manometer

3
Yes

Drain valve / fill valve

Yes

Shut off valve

Yes

Air purge valve

Yes

Total water volume

Minimum water volume in the system

1
Brass

Safety valve

Safety devices

EBHQ008BV3

-15

Ambien Min.
t
Max.

Water
side
Water side Heat
exchanger

CWB

Item

01

5.5 (7)
10 (8.0)
Fan motor thermal protection

02

Fuse

03

Pressure relief valve

04

Flowswitch

05

Clixon expansion vessel heater

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

Specifications

2-2 Electrical Specifications


Compressor
component

EBHQ006BV3

Main power supply

Name
Phase

Voltage range
Current

Hz

50

Voltage

230

Min.

-10

Max.

10

Maximu Heating A
m
Cooling A
running
current

Recommended
fuses
Zmax

1~

Frequency

18

11
11

20

Text

Notes

16.25

Starting Heating A
current Cooling A

Current

EBHQ008BV3

V3

0.42
EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes,
voltage fluctuations and flicker in public low-voltage supply systems for equipment with rated 75A

Notes
(1) EN14511: cooling Ta 35C - LWE 18C (Dt = 5C); heating Ta DB/WB 7C/6C - LWC 35C (Dt = 5C)
(2) EN14511: cooling Ta 35C - LWE 7C (Dt = 5C); heating Ta DB/WB 7C/6C - LWC 45C (Dt = 5C )
(3) The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to
sound spectrum drawing for more information.
(4) Condition: Ta DB/WB 7C/6C - LWC 35C (DT = 5C)
(5) Condition: Ta 35C - LWE 7C ( DT = 5C)
(6) 15C-25C: BUH only, no heat pump operation = during commisioning
(7) Including piping + PHE; excluding expansion vessel
(8) Excluding water volume in the unit. In most applications this minimum water volume will have a satisfying result. In critical processes or in rooms with a high heat load though, extra
water volume might be required. Refer to operation range for more info.
(9) See separate drawing for operation range
(10) The 3-way valve should be mounted as close as possible to the outdoor unit
(11) Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents
produced by equipment connected to public low-voltage systems with input current \>16A and 75A per phase
(12) Wiring connections: cf. connection diagram for full wiring overview; Select diameter and type according to local regulations; For more details on voltage range and current cf.
EBHQ installation manual
(13) Power supply compressor compartment is for compressor, fan, pump and controller
(14) In accordance with EN/IEC 61000-3-11, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply with Zsys
(system impedance) Zmax
(15) EN/IEC 61000-3-11: European/international technical standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage supply systems for
equipment with rated 75A

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

Options

3-1

Options

EBHQ006-008BV3
EKMBUH
EKCBH/X008
Factory mounted optional equipment for EKMBUHB*6V3

1
3

Reference
6V3

Description
Back-up heater 6kW1~230V

EKMBUHB*6V3

Combination table for *KCB(H/X)008B*V3


EBHQ006B*V3
EBHQ008B*V3
EKMBUHB*6V3

Heating only indoor unit


Reversible indoor unit
Back-up heater kit

EKCBH008BAV3
(1)
(1)
(1)

EKCBX008BAV3
(1)
(1)
(1)

EBHQ006B*V3*
(1)

EBHQ008B*V3*
(1)

EKCBH008BBV3
(1)
(1)

EKCBX008BBV3
(1)
(1)

Kit availability for *BHQ006-008B*


EKBPHT08BA

Bottom plate heater (2)

Kit availability for *KCB(H/X)008B*


Reference

Description
Heating only model *KCBH008B*#
Reversible model *KCBX008B*#

NOTES

#
V3
V3

EKHWS150*3V3
EKHWS200*3V3
EKHWS300*3V3

Stainless steel domestic hot water tank 150l 1~230V


Stainless steel domestic hot water tank 200l 1~230V
Stainless steel domestic hot water tank 300l 1~230V

EKHWS200*3Z2
EKHWS300*3Z2

Stainless steel domestic hot water tank 200l 2~400V


Stainless steel domestic hot water tank 300l 2~400V

EKHWSU150*3V3
EKHWSU200*3V3
EKHWSU300*3V3

Stainless steel domestic hot water tank for UK 150l 1~230V


Stainless steel domestic hot water tank for UK 200l 1~230V
Stainless steel domestic hot water tank for UK 300l 1~230V

EKHWE150*3V3
EKHWET150*3V3
EKHWE200*3V3
EKHWE300*3V3

Enameled steel domestic hot water tank 150l 1~230V


Wallmounted enameled steel domestic hot water tank 150l 1~230V
Enemaled steel domestic hot water tank 200l 1~230V
Enemaled steel domestic hot water tank 300l 1~230V

EKHWE200*3Z2
EKHWE300*3Z2

Enemaled domestic hot water tank 200l 2~400V


Enemaled domestic hot water tank 300l 2~400V

EKRP1HBA

Digital I/O PCB (3)

EKRTWA
EKRTR1
EKRTETS

Wired room thermostat option kit


Wireless room thermostat option kit (incl. receiver)
External temperature sensor option kit

EKSOLHWAV1
EKSR3PA

Solar kit - Connection kit between solar panel, monobloc & tank
Solar kit - Control panel

1. Obligatory combination
2. Heater tape that can be fixed on the bottom plate to prevent excessive ice formation.
3. Address card that provides two additional output connections (remote alarm and remote ON/
OFF signalisation). In *KSOLHWAV1, the same digital I/O PCB as for *KRP1HB is already
included.
4. EKRTETS can only be used in combination withe EKRTR1
5. For further options on tanks (wall mounting bracket, valve kits, ...) see combination table of
tanks.

Remark: Other combinations than mantioned in this option TW are not guaranteed.

3TW60419-2
(%+4%9
(.0%8+
(.&%+;
.LWDYDLODELOLW\IRU .+:
5HIHUHQFH

'HVFULSWLRQ
.+:( 7  9=
.+:6 9=
.+:689


$

$

$
 $%  $%  $%
$

$

$

%

%

%

.8+:$

2SWLRQNLWIRU8. .+:68a 9

.8+:%

2SWLRQNLWIRU8. .+:68a9 

.8+::%

2SWLRQNLWIRU8. .+:68a9 

.62/+:$9

6RODUNLW 

.:%6::

:DOOEUDFNHWIRU .+:6 8  9RU .6::9

5HPDUN2WKHUFRPELQDWLRQVDUHQRWJXDUDQWHHG

127(6

 .LWWREHPRXQWHGRQGRPHVWLFKRWZDWHUWDQNWKDWSURYLGHVFRQQHFWLRQWRVRODUSDQHOVIRUDGGLWLRQDOZDWHUKHDWLQJ
 ,ILQVWDOODWLRQRQWDQN$YHUVLRQERWKNLWVDUHUHTXLUHG
 .LWLVRQO\QHFHVVDU\ZKHQLQVWDOOLQJ .62/+:$9RQD8.WDQN%VHULHV .+:68  %9
 .8+:%  .8+:$ ZD\YDOYHDQGZD\YDOYHDFFHVVRULHV 
.8+::% ZD\YDOYHDQGZD\YDOYHDFFHVVRULHV

7:

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

Options

3-1

Options

EBHQ006-008BV3
EKMBUH
EKCBH/X008

Bivalent system
Space heating with an auxiliary boiler (alternating operation)

Space heating application by either the Daikin unit or by an auxiliary boiler


connected in the system. The decision whether either the EBHQ* unit or
the boiler will operate can be achieved by an auxiliary contact or an EKCB *
indoor controlled contact.
The auxiliary contact can e.g. be an outdoor temperature thermostat, an
electricity tariff contact, a manually operated contact, etc. See Field wiring
conguration A.
The EKCB* unit controlled contact (also called permission signal for the
auxiliary boiler) is determined by the outdoor temperature (thermistor
located at the outdoor unit). See Field wiring conguration B.
Bivalent operation is only possible for space heating operation, not for
the domestic water heating operation. Domestic hot water in such an
application is always provided by the domestic hot water tank which is
connected to the Daikin unit.
The auxiliary boiler must be integrated in the piping work and in the eld
wiring according to the illustrations below.

CAUTION

Be sure that the boiler and the integration of the boiler in the system is
in accordance with relevant local laws and regulations.
Always install a 3-way valve, even if no domestic hot water tank is
installed. This to ensure that the freeze protection function can operate
when the boiler is active.
1
2
3
4
5
6
7
9
10
11
14
15
16
17
FHL 1 ... 3
C
I
1 Motorised 3-way valve
2 Boiler

Outdoor unit
Heat exchanger
Pump
Shut-off valve
Heater kit
Collector (eld supply)
Motorised 3-way valve
(delivered with the domestic hot water tank)
Booster heater
Heat exchanger coil
Domestic hot water tank (optional)
Boiler (eld supply)
Aquastat valve (eld supply)
Shut-off valve (eld supply)
Non-return valve (eld supply)
Floor heating loop (eld supply)
Control box
User interface

Field wiring conguration A

Daikin can not be put responsible for incorrect or unsafe situations in


the boiler system.
EKCB(H/X)*/auto/boiler

EKCB(H/X)*X2M

Boiler thermostat
input

Auxiliary contact (normal closed)

Heating demand room thermostat (optional)

K1A

Auxiliary relay for activation of EBHQ* unit (eld supply)

K2A

Auxiliary relay for activation of boiler (eld supply)

3TW60419-3

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

Options

3-1

Options
Operation

EBHQ006-008BV3
EKMBUH
EKCBH/X008

Conguration A
When the room thermostat requests heating, either the EBHQ* unit or the
boiler starts operating, depending on the position of the auxiliary contact (A).

Field wiring conguration B

Conguration B
When the room thermostat requests heating, either the EBHQ* unit or the
boiler starts operating, depending on the outdoor temperature (status of
permission signal for the auxiliary boiler).

When the permission is given towards the boiler, the space heating operation
by the EBHQ* unit will be automatically switched off.
Boiler thermostat
input
CAUTION

Cooling demand room thermostat (optional)

Heating demand room thermostat (optional)

Com

Common room thermostat (optional)

K1A

Auxiliary relay for activation of boiler unit (eld supply)

KCR

Permission signal for the auxiliary boiler

Make sure that return water to the EBHQ* heat exchanger never exceeds
55C.
For this reason, never put the target leaving water temperature set point
on the boiler controller above 55C and install an aquastat(a) valve in the
return water ow of the EBHQ* unit.
Make sure that the non-return valves (eld supply) are correctly installed
in the system.
Make sure that the room thermostat (th) is not frequently turned ON/OFF.
Daikin shall not be held liable for any damage resulting from failure to
observe this rule.

NOTES

Make sure to congure the DIP switch SS2-3 on the PCB of the EKCB(H/X)* switch box correctly.
For conguration B: Make sure to congure the eld settings correctly.
Conguration A
Make sure that auxiliary contact (A) has sufcient differential or time delay so as to avoid frequent changeover between the EBHQ* unit and the boiler. If the
auxiliary contact (A) is an outdoor temperature thermostat, make sure to install the thermostat in the shade, so that it is not inuenced or turned ON/OFF by
the sun.
Conguration B
Make sure that the bivalent hysteresis has sufcient differential to avoid frequent changeover between the EBHQ* unit and the boiler. As the outdoor
temperature is measured via the outdoor unit air thermistor, make sure to install the outdoor unit in the shade, so that it is not inuenced by the sun.
Frequent switching may cause corrosion of the boiler in an early stage. Contact the manufacturer of the boiler.
During heating operation of the EBHQ* unit, the unit will operate so as to achieve the target leaving water temperature as set on the user interface. When
weather dependent operation is active, the water temperature is determined automatically depending on the outdoor temperature.
During heating operation of the boiler, the boiler will operate so as to achieve the target leaving water temperature as set on the boiler controller.
Never set the target leaving water temperature set point on the boiler controller above 55C.
Make sure to only have 1 expansion vessel in the water circuit. An expansion vessel is already premounted in the Daikin unit.

(a)

The aquastat valve must be set for 55C and must operate to close the return water ow to the unit when the measured temperature exceeds 55C. When the temperature
drops to a lower level, the aquastat valve must operate to open the return water ow to the EBHQ unit again.

Heating Daikin Altherma low temperature split

3TW60419-3

Daikin Altherma low temperature split EBHQ-BV3

Capacity tables

4-1

Heating Capacity Tables

3
1
4

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

Capacity tables

4-2

Cooling Capacity Tables

1
4

10

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

Dimensional drawings

5-1

Dimensional Drawings

(%+4%9
0$/(

0LQLPXPVHUYLFHDQGLQVWDOODWLRQVSDFH
VFDOH

)(0$/(

1
5

QRWHZDOOKHLJKWRQDLURXWOHWVLGHPXVWEHOHVVWKDQ

6FDOH
[KROHVIRUDQFKRUEROWV
0RU0

[GUDLQKROH

1U















1DPH
:DWHULQOHWPDOH
:DWHURXWOHWPDOH
3RZHUVXSSO\LQWDNH
&RPPXQLFDWLRQFDEOHLQWDNH
7KHUPLVWRUFDEOHLQWDNH
'UDLQDQGOOYDOYH
%ORZRIIYDOYH
3XPS
([SDQVLRQYHVVHO
:DWHUOWHU
$LUSXUJH
6ZLWFKER[
2XWGRRUDLUWKHUPLVWRU
VKXWRIIYDOYHV GHOLYHUHGZLWKXQLW
&HQWHURIJUDYLW\

7:

Heating Daikin Altherma low temperature split

11

Daikin Altherma low temperature split EBHQ-BV3

Piping diagrams

6-1

Piping Diagrams

EBHQ006-008BV3
EKMBUH
EKCB(H/X)008BBV3

Outdoor unit
EBHQ*BAV3

Expansion
vessel

BUH-KIT
EKMBUHBA6V3

Evaporator

Air purge
Pressure
gauge

Safety valve

Air purge

Condensor

Field installation

R12T

Blow off

Refrigerant side

R11T

Pump

Shut off valve

Refr. out

Water outlet
Electric heater
body

Thermistor
R11T
R12T
R13T
R14T

Refr. in

Drain port
Plate heat
exchanger

Description
Outlet water heat exchanger
thermistor
Outlet water backup heater thermistor
Refrigerant liquid side thermistor
Inlet water thermistor

Flow switch

Field installation
Shut off valve

Refr. in

Filter

Water inlet
Refr. out

Drain port
Cooling (EBHQ)
Cooling (E(B/D)HQ)

NOTES

: Check valve,

12

: Flare connection,

: Screw connection,

: Flange connection,

: Pinched pipe,

Heating Daikin Altherma low temperature split

: Spinned pipe

3TW60415-1A

Daikin Altherma low temperature split EBHQ-BV3

Wiring diagrams

7-1

Wiring Diagrams - Single Phase

1
7

Heating Daikin Altherma low temperature split

13

Daikin Altherma low temperature split EBHQ-BV3

External connection diagrams

8-1

External Connection Diagrams


For more details, please check unit wiring diagram

Electrical connection diagram, only valid for units in combination with EKCB(H/X)*BB*-units
Standard parts
Power supply

1
8

Outdoor unit

Only for normal power supply installation unit power supply:


230V + earth

3 core

Only for benet kWh rate power supply installation unit benet
kWh power supply: 230V + earth

3 core

L-N-earth

L-N-earth
230V

Normal kWh rate power supply for indoor unit: 230V + earth

Only for *KBPHT* option

3 core

2 core
earth 1-2-3

2 core
Benet kWh rate power supply contact

(Common)
(BPH Control)
(exp. vessel heater)
(pump)

Bottom plate
heater

Optional parts

signal
signal

8 core

3 core

4 core

booster heater power supply (3kW): 400V or 230V + earth

4 core

Optional power supply

Backup heater kit *KMBUH*6v3


5 core
3 core
L-N-earth

2 core

Optional parts

earth 1-2-3

signal

30-31 earth

Domestic hot
water tank

BUH control

L1-L2-earth or L-N-earth
2-way valve

Field supply

Indoor unit

Only for *KHWSU*V3

power supply: 230V + earth

Only for *KRP1HB* & *KSOLHWAV1


2 core

2 core

Alarm indication
Alarm output

clixon

2 core

Power supply
booster heater

5 core

Cooling/heating
on/off output

1-2-earth

Cooling/heating
On/off indication

2 core
BSK: 1-2 Solar interlock
Solar input

230V or 400V

Q2L - Clixon
booster heater

Only for *KSR3PA option


2 core

Changeover to
boiler output

2 core

R5T - Thermistor
water temperature

signal
solar pump

Q*L
clixon

signal
2 core

NO valve:
NC valve:
Room thermostat

Only for *KSOLHWAV1


2 core

3-way valve
M3S (when *KHW is installed) selection
domestic hot water-oorheating

Boiler

3 core

2-way valve
M2S (*KCBX* units) for
cooling mode

Optional parts

Possibility 1

3 core for C/H application


2 core for H application

Only for *KRTW (wired room thermostat)

Possibility 2

5 core for C/H application


4 core for H application

Only for *KRTR (wireless room thermostat)

2 core

Only for *KRTETS


2 core (3m included)

R2T:
External sensor
(oor or ambient)

signal

user interface
signal

NOTES

1. Keep mimimum distance between signal cable and power cable >5cm
2. Field wiring:
: Field supply,
: Delivered with unit / option

14

Heating Daikin Altherma low temperature split

3TW60416-2A

Daikin Altherma low temperature split EBHQ-BV3

Sound data

9-1

Sound Pressure Spectrum - Heating

EBHQ006-008BV3

EBHQ006 *
Heating

EBHQ008*
Heating

1
Sound pressure level (dB)

Sound pressure level (dB)

Octave band center frequency (Hz)

Octave band center frequency (Hz)

NOTES

1
2
3
4

Data is valid at free field condition (measured in a semi-anachoic room)


dBA = A-weighted sound pressure level. (A-scale according to IEC)
Reference acoustic pressure 0dB = 20 Pa
If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections
Microphone

Location of microphone

3TW60417-1

Heating Daikin Altherma low temperature split

15

Daikin Altherma low temperature split EBHQ-BV3

Sound data

9-2

Sound Pressure Spectrum - Cooling

EBHQ006-008BV3

EBHQ006 *
Cooling

EBHQ008*
Cooling

1
Sound pressure level (dB)

Sound pressure level (dB)

Octave band center frequency (Hz)

Octave band center frequency (Hz)

NOTES

1
2
3
4

Data is valid at free field condition (measured in a semi-anachoic room)


dBA = A-weighted sound pressure level. (A-scale according to IEC)
Reference acoustic pressure 0dB = 20 Pa
If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections
Microphone

Location of microphone

16

3TW60417-1

Heating Daikin Altherma low temperature split

Daikin Altherma low temperature split EBHQ-BV3

10

Operation range

10 - 1 Operation Range
outdoor temp. (CDB)

EBHQ-BV3

EBHQ006/008BAV3 + EKCBX008B*V3 + EKMBUHBA6V3


PULL DOWN AREA

1
10

outdoor temp. (CDB)

leaving evaporator
water temperature (C)

EBHQ006/008BAV3 + EKCB(H/X)008B*V3 + EKMBUHBA6V3


ONLY BACKUP HEATER OPERATION (NO OUTDOOR UNIT OPERATION)

(*) EBHQ...BA + EKCB...B* + EKMBUHBA:


Models have a freeze prevention function using the pump and backup heater to keep the
water system safe from freezing in all conditions. In case accidental or intentional power
shutdown is likely to happen, we recommend to use glycol.

outdoor temp. (CDB)

leaving evaporator
water temperature (C)

EBHQ006/008BAV3 + EKCB(H/X)008B*V3 + EKMBUHBA6V3

ONLY BOOSTER HEATER OPERATION

domestic hot water


tank temperature (C)

outdoor temp. (CDB)

EBHQ-BV3

4TW60413-1A

EBHQ006/008BAV3 + EKCBX008BBV3
PULL DOWN AREA

outdoor temp. (CDB)

leaving evaporator
water temperature (C)

EBHQ006/008BAV3 + EKCB(H/X)008BBV3
ONLY DURING START-UP

(*) EBHQ...BA + EKCB...BB:


Models have a freeze prevention function using the pump to keep the water system safe
from freezing in all conditions. The use of glycol is obligatory.

outdoor temp. (CDB)

leaving condensor
water temperature (C)

EBHQ006/008BAV3 + EKCB(H/X)008BBV3
ONLY BOOSTER HEATER OPERATION

domestic hot water


tank temperature (C)

Heating Daikin Altherma low temperature split

4TW60413-1A

17

Daikin Altherma low temperature split EBHQ-BV3

11

Hydraulic performance

11 - 1 Static Pressure Drop Unit

EBHQ006-008BV3

ESP [kPa]

11

Flow [l/min]
III high speed
II medium speed
I low speed

ESP: external static pressure


Flow: waterflow through the unit

NOTES

1
2

Selecting a flow outside the curves can cause damage to or malfunctioning of the unit.
See also minimum and maximum allowed water flowrange in the technical specifications.
Water quality must be according to EN directive EC 98/83 EC

4TW60419-1
18

Heating Daikin Altherma low temperature split

The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.
has compiled the content of this leaflet to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of i ts content and the products
and se rvices pr esented ther ein. S pecifications are su bject t o c hange
without prior notice. Daikin Europe N.V. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the us e and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

Daikin E urope N.V. participates in the Eu rovent Certification programme for Air conditioners ( AC), Li quid Chil ling P ackages
(LCP) and Fan coil units (FCU), Check ongoing validity of c ertificate online: www.eurovent-certification.com o
ru
sing:
www.certiflash.com

BARCODE

Daikin products are distributed by:

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

EEDEN12-725 08/12 Copyright Daikin


The present publication supersedes EEDEN11-725

Daikins uni que pos ition as a ma nufacturer of a ir


conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. F or s everal yea rs Daik in has had the
intention to become a l eader in th e pr ovision o f
products th at ha ve li mited i mpact on t he e nvironment. This challenge demands the eco design and
development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.