Você está na página 1de 24

In-band EMS Configuration for RTN

RTSO/MTS (http://10.7.44.64/)

Good to know
GNE: A GNE is connected to the NMS through a local area network (LAN) or wide area
network (WAN). Its application layer can directly communicate with the NMS
application layer.

Non-GNE: A non-GNE communicates with the GNE through the DCN channels between
NEs. It is recommended that fewer than 50 non-GNEs are affiliated to a GNE.
Access Control: The access control function is used so that the NE can be connected to
the NMS through an Ethernet service port. The PSN transmits DCN packets between the
NMS and the GNE when transmitting Ethernet services. In this case, the Ethernet service
port on the GNE should be enabled with the access control function.

N.B. From next page, consider the steps only. For value setting , follow the EMS plan
provided by TP.

Step-1(Check Plan)

10.216.4.69

GNE

Non-GNE

Non-GNE

Step-2(Check backhaul configuration part)


START>RUN>cmd
Ping Access Control GW IP -t
If successful, go to next step. If not, confirm configuration part from OTS in case of
IPBH nodes and from SCL/F&H in case of NTTN cisco/juniper nodes.

Step-3(Add VLAN)

DHDMRK

Step-1

Step-5

301
Step-6

Step-2
Step-3

Step-4

Step-7

Step-4(Access Control)
Select the port which is passing Eth traffic

Access control IP
and Subnet Mask

Only need for NE which is directly connected to


switch

Step-5(Port Setting- FE/GE)

Step-6(Port Setting- IF)

Step-7(Add NE IP and GW IP)

10.216.7.2
10.216.4.69
115

N.B. After this step, youll require re-login

Step-8(Check Static Route)

2
3

0.0.0.0

0.0.0.0

10.216.4.69

Ping to server 10.165.173.18 &


10.184.173.18 and confirm connectivity
N.B. This option is available at the version of
5.76.03.XX or later

Step-9(Reachability Test-Optional)

Step-10( NE naming, NE ID, Extended ID)

Step-11( Add VLAN to connect iPASOLINK with PNMS through RTN)

Add NEC VLAN @ all


possible
Eth and IF ports
as per planned NE
diagram

Step-1(Add VLAN)

4
5

301

6
2

Step-2(Port Settings-FE/GE)

Step-3(Port Settings-IF)

Step-4(NE IP and GW IP)

Step-5(Reachability Test-Optional)

Ping to GNE(Here 10.216.4.70 and confirm connectivity


N.B. This option is available at the version of 5.76.03.XX or later

Step-6( NE naming, NE ID, Extended ID)

Step-7( Add VLAN to connect iPASOLINK with PNMS through RTN)

Add VLAN @ all possible


Eth and IF ports
as per planned NE
diagram

NOTES
No access control setting is required for Non-GNE.
Better to start from opposite end.
Updating NE IP will disconnect NE from WebLct. To reconnect use IP auto-discovery or
use any free IP of allocated IP block.
As Non-GNE cant be checked remotely, confirm integration locally using NE search.
Must Remove all old EMS cables from NMS/COM ports. Otherwise it may create
Ethernet loop.
Ensure each IF/Modem port naming, each used FE/Ethernet port naming during
working with Each NE.
For any query or observation, send e-mail to mts@grameenphone.com.

Thank you