Você está na página 1de 19

New range

Hear the difference...


Feel the power...
Experience the performance...

HEAR THE

DIFFERENCE

Rotorex technology: fan motor assembly


with maximised airflow and minimised airflow noise levels.

The design of CIATs innovative JET+


diffuser is based on Bernouillis principle of fluid dynamics
and NACA 0012 aircraft airfoils.

FEEL THE

POWER

Providing the best combination of tube geometry and fin


design on the market, CIAT yet again proves its excellence
in coil design.

Incoming and outgoing flows of air are purified to ensure


efficient heat transfer and the tapered intake baffles drive
noise levels even lower.

EXPERIENCE THE PERFORMANCE


This new HELIOTHERME range features CIATs full spectrum of expertise so that you can fully benefit from:
all the advantages of a standard high-efficiency diffuser
the quiet operation and efficiency of a high-efficiency Rotorex fan motor,
heating capacity provided by a high-efficiency coil.

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

HELIOTHERME H4000

Heliotherme range

Heliotherme range

HELIOTHERME H4000
APPLICATIONS
Available as a wall-mounted or ceiling-mounted version, HELIOTHERME is the simple and economic heating or cooling solution
in the following applications:

Industry: workshops, garages, storage warehouses, distribution centres, etc.


Tertiary: shops, sports halls, multi-purpose rooms, etc.

Storage warehouses
and distribution centres

Exhibition halls

Supermarkets

HOW

IT WORKS

HELIOTHERME units are installed at the end of a central heating or cooling system (boilers, air-source or water-source heat
pump, reversible unit)

AQUACIAT 2 LD

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

RANGE
Supply medium

LP water

HP superheated water - Oil

HP steam

Electricity

Standard drive

THREE-PHASE 2 speeds SINGLE-PHASE 1 variable speed


IP44/54 depending on the model

Reinforced versions

Corrobloc version IP55/65 TBS 700 hours

Coil (tube/sheet)

Copper/Aluminium

Reinforced versions

Steel/Aluminium

Cupronickel/Alu

Stainless steel/Alu

304L stainless steel tubes Heresite coating

Casing

Precoated off-white (RAL 7035) galvanised steel


Condensate pan + built-in nautical coupling for cooling

Reinforced versions

304L stainless steel Epoxy coating

ATEX versions

LCIE 03 ATEX 6392 X Zone 1 or 2 IIB or IIC T4 or T6

Standard

Reinforced version
(high corrosion resistance)

ATEX version

INSTALLATION
The HELIOTHERME range meets APSAD and NFPA recommendations on air velocities along the edges of units.
All are less than 5 m/s at 0.5 m from the diffuser and thus do not interfere with sprinkler systems.

MIN
0,145m
MIN
0,145m

MIN
2,5m

MAX
4,5m

Wall
mounted

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

Ceiling
mounted

MIN
4,5m

MAX
10m

HELIOTHERME H4000

Heliotherme range

Heliotherme range

HELIOTHERME H4000
TECHNICAL

DESCRIPTION

High-efficiency fan motor assembly:


Silent FMA features a contoured propeller to ensure the best compromise between
air flow efficiency and acoustic comfort.
The Rotorex design (windings inserted in the fan hub) keeps the motor cool to ensure
that it operates at optimum efficiency.

Three versions are available:


Three-phase with 2 speeds (accessory: LS/HS switch)
Single-phase with 1 variable speed (accessory: 5-speed autotransformer)
Corrobloc version guaranteed to withstand corrosive environments.
Corrobloc FMA
IP65 / TBS 700 hours

Heat exchanger:
HIGH EFFICIENCY heat exchanger with tapered intake baffles available in four versions:
LP hot or cold water version Available with 1, 2 or 3 rows:
dia. 9.52 mm copper tube
Embossed aluminium fins Thickness 0.1 mm
2.1 mm fin pitch
32 mm equilateral geometry
Advantage: Excellent thermal yield (dry transfer coefficient) > 50 W/m2.k)
HP superheated water - oil version Available with 1 row:
Heavy-gauge steel tube (dia. 16 mm) (Stainless steel available on request)
Embossed aluminium fins Thickness 0.285 mm
2.5 mm fin pitch
Usable with thermal oils
Advantage: robust finned aluminium coil block suitable for use in industrial environments
(dirty air) and may be cleaned using a high-pressure water jet.
HP steam version Available with 1 row:
Heavy-gauge cupronickel tube (dia. 16 mm)
Embossed aluminium fins Thickness 0.1 mm
2.5 mm fin pitch
Advantage: excellent corrosion resistance thanks to chemicals pumped through steam
network piping.

Options available:
- Stainless steel tube
- Heresite coating
- Precoated fins

Electric version: Available with 4 power options:


Stainless steel single-tube heating element
Embossed aluminium fins Thickness 0.1 mm
2.5 mm fin pitch
Double overheating thermostat with automatic and manual reset for compliance with
fire safety standards (CH37)
Advantage: Heating elements inserted directly into the finned block ensure excellent
heat transfer.

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

HELIOTHERME H4000

Heliotherme range
Casing:
Elegant galvanised steel casing precoated in off-white
(stainless steel or epoxy paint available on request).
Built-in COOLING condensate drain pan for with
antibacterial design (performated bottom) and
nautical coupling.
Intake section optimised for improved air flow performance
and acoustic comfort levels.
Advantages:
- Its classic design means that it can be easily installed anywhere.
- No need to add an unsightly condensate drain pan.
- Quick and extremely simple connection of the condensate tube
without any need for a clamp.

Diffuser:
Basic version:
Single-deflection diffuser with directional louvre.
Light-grey galvanised steel louvre.
JET+ version (fitted as standard):
Double-deflection diffuser.
JET+ aluminium louvre with NACA 0012 airfoil design.
Each louvre is directional.
Advantages:
- Air streams can be adjusted in four directions to optimally cover all sections
of a space and limit draughts.
- Laminar air flows for better acoustic comfort (zero turbulence at the diffuser outlet).
- The resulting aerodynamics, related to the curve of the airfoil, increase the velocity
of air streams (pressure drop along the lower surface of the blade) and thereby
increase the reach of the air streams and the induction rate.
- Limited stratification.
- Reduced building warm-up times:

Proven energy savings of 15-20%

Operating cycle of a HELIOTHERME unit


equipped with a JET+ diffuser and a basic diffuser

Temperature
23C

Ceiling temp. with basic diffuser

22.5C
22C
21.5C
21C

Stratification zone
(= loss of heat)

20.5C
20C
19.5C

Ceiling temp. with JET+ diffuser


19C
18.5C
18C
17.5C
17C

Occupied space temp. with basic diffuser


Occupied space temp. with JET+ diffuser

16.5C
16C

Running time with JET+ diffuser

15.5C

Running time with basic diffuser

15C

Time
7h00

8h00

9h00

10h00

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

11h00

Heliotherme range

HELIOTHERME H4000
ECONOMIC

COMPARISON OF A

JET+

DIFFUSER AND A BASIC DIFFUSER

Comparison between a HELIOTHERME air heater equipped with a JET+ diffuser and a HELIOTHERME air heater
equipped with a basic supply outlet.

Space volume:

600 m2 with a 6 m ceiling, or 3600 m3

Insulation:

light (such as in a workshop or small distribution centre)

Temperature to be maintained in occupied space:

17C

Average outdoor temperature used:

5C

Heating period:

November to March

Heating time range:

7.00 to 19.00

Necessary heating capacity:

80W/m2 or 48 kW (at 5C)

BASIC DIFFUSER

JET+ DIFFUSER
INSTALLATION COST
Mixing rate: 4 (or 14,400 m3 to be provided)
(Rate lower thanks to longer throw and better induction)

Mixing rate: 6 (or 21,600 m3 to be provided)


Unit selected:
- Three H4501 single-phase units
Total flow rate delivered = 21,300 m3/h
Total heating capacity delivered = 97 kWh

Unit selected:
- Three H4451 single-phase units
Total flow rate delivered = 15,600 m3/h
Total heating capacity delivered = 73 kWh

Total price of air heaters

Total price of air heaters

(savings of nearly 18%)

OPERATING COST
Average ceiling temperature = 20C
(Temperature lower thanks to better induction and higher air velocities)

Average ceiling temperature = 23C


Basis of the analysis:
1 kWh with a gas-fired boiler = 0.047/kW (installation=80%)
Total number of heating days = 100 (20 per month from November to March)

Running time needed each day to


maintain 17C in the comfort zone
480 minutes a day
or 800 hours a year

Running time needed each day to


maintain 17C in the comfort zone
380 minutes a day
or 634 hours a year
166 less hours of operation

38,400 kW of boiler power used


30,432 kW of boiler power used
Annual heating cost

Annual heating cost (savings of 20%)

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

PERFORMANCE

SPECIFICATIONS OF THREE-PHASE

HELIOTHERME

UNITS

HEATING - THREE-PHASE motor


Model

No.
rows

Supply air velocity

Flow
rate

Air velocity

Three-phase motor
HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

HIGH
LOW

m3/h
2600
2210
2480
2040
2165
1775
4000
3480
3800
3310
3400
2960
5400
3910
5300
4140
5000
3910
7500
5740
6900
5400
6500
5020
11140
9635
10510
8820
9175
7545

m/s
3.92 m/s
3.33 m/s
3.74 m/s
3.07 m/s
3.26 m/s
2.67 m/s
4.35 m/s
3.79 m/s
4.13 m/s
3.60 m/s
3.70 m/s
3.22 m/s
4.36 m/s
3.16 m/s
4.28 m/s
3.34 m/s
4.04 m/s
3.16 m/s
4.46 m/s
3.41 m/s
4.10 m/s
3.21 m/s
3.86 m/s
2.98 m/s
4.47 m/s
3.87 m/s
4.22 m/s
3.54 m/s
3.68 m/s
3.03 m/s

4350

2
3
1

4400

2
3
1

4450

2
3
1

4500

2
3
1

4630

2
3

Throw (metres)
Wall
22
17
20
15
18
14
25
21
23
18
22
17
28
23
25
21
24
20
30
26
28
24
26
23
29
24
26
22
25
21

Suspended
6
3.5
5
2.5
4.5
2
8
5
7
4
6.5
3.5
9
5.5
8
4.5
7.5
4
10
7
9
6
8.5
5.5
11.5
8.5
10.5
7.5
10
7

Sound
pressure

Heating cap. (kW)


LP HW
13,90 kW
13,10 kW
25,20 kW
22,90 kW
30,90 kW
27,40 kW
19,80 kW
18,80 kW
3710 kW
34,70 kW
46,10 kW
42,60 kW
27,70 kW
24,40 kW
51,40 kW
45,50 kW
66,50 kW
52,60 kW
37,10 kW
33,50 kW
66,90 kW
59,30 kW
88,40 kW
75,90 kW
54,50 kW
51,60 kW
102,00 kW
93,90 kW
130,00 kW
115,00 kW

SHW
35.87 kW
32.07 kW

STEAM
40.57 kW
36.92 kW
-

48.85 kW
44.55 kW

56.71 kW
52.75 kW
-

100.55 kW 100 kW
83.79 kW 86.82 kW
155.4 kW
141 kW

149.8 kW
139 kW
-

dB(A)
48
44
49
45
50
46
55
51
55
51
56
52
56
49
57
50
59
52
56
50
57
51
58
52
55
48
56
49
57
49

ELECTRIC HEATING - THREE-PHASE motor


Model

Supply air velocity Flow rate


Three-phase motor

4350
4400

HIGH
LOW

HIGH
LOW

HIGH

4500

LOW

HIGH
LOW

Air velocity Throw (metres)

m3/h

m/s

Wall

2600

3.92 m/s

22

2210

3.33 m/s

17

4000

4.35 m/s

25

3480

3.79 m/s

21

7500

4.46 m/s

30

5740

3.41 m/s

26

6900

4.10 m/s

28

5400

3.21 m/s

24

Electric heating cap. (kW)


Total

No. of stages

9.6 kW

18.9 kW

28.8 kW

43.2 kW

Sound
pressure

Capacity per stage

dB(A)

2.4 kW

48

7.2 kW

44

5.4 kW

55

13.5 kW

51

10.8 kW

56

18 kW

50

14.4 kW x 3

57
51

Specifications determined using the following information:

Hot water (LP HW):


90-70C / 15C RT 50% RH
Superheated water (HP SHW): 180-120C / 15C RT 50% RH
Steam (HP STEAM):
175C 8 bar / 15C RT 50% RH
Electric:
3-ph 400 V coil supply / 15C RT 50% RH

Air throw:

Air velocity:

exiting JET+ diffuser

Sound pressure:

measured 5 metres from unit, directivity 2, attenuation of 22 dB

* with JET+ diffuser for a residual velocity of 0.1 m/s


* defined with t ST/RT of 15C
* with LP water or electric heating

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

HELIOTHERME H4000

Heliotherme range

Heliotherme range

HELIOTHERME H4000
PERFORMANCE

SPECIFICATIONS OF SINGLE-PHASE

HELIOTHERME

UNITS

HEATING - SINGLE-PHASE motor


Model

No. rows

Supply air velocity

Flow rate

Air velocity

SINGLE-PHASE
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*

m3/h
2600
2360
2400
2030
2075
1780
4200
3914
3800
3550
3450
3220
5200
4100
4700
3700
4550
3650
7100
5700
6600
5380
6200
5055
10450
8900
9610
7630
8280
6270

m/s
3.92 m/s
3.56 m/s
3.62 m/s
3.06 m/s
3.13 m/s
2.68 m/s
4.57 m/s
4.26 m/s
4.13 m/s
3.86 m/s
3.75 m/s
3.50 m/s
4.20 m/s
3.31 m/s
3.80 m/s
2.99 m/s
3.68 m/s
2.95 m/s
4.22 m/s
3.39 m/s
3.92 m/s
3.20 m/s
3.69 m/s
3.01 m/s
4.19 m/s
3.57 m/s
3.86 m/s
3.06 m/s
3.32 m/s
2.52 m/s

4350

2
3
1

4400

2
3
1

4450

2
3
1

4500

2
3
1

4630

2
3

Throw (metres)
Wall
22
18
20
15
15
14
26
24
23
19
23
20
27
24
21
18
18
17
28
26
26
24
24
23
28
22
24
20
21
19

Heating cap. (kW)

Suspended
6
4
5
2.5
2.5
2
8.5
7.5
7
4.5
7
5.5
8.5
6
4.5
4
3.5
3
9
7
7
6
6.5
5.5
10.5
8
8.5
6
6.5
5

LP HW
13,90 kW
13,40 kW
24,80 kW
22,80 kW
30,10 kW
27,40 kW
20,20 kW
19,70 kW
37,10 kW
35,90 kW
46,50 kW
44,70 kW
27,30 kW
24,90 kW
48,50 kW
42,90 kW
63,00 kW
55,20 kW
36,30 kW
33,40 kW
65,50 kW
59,20 kW
85,90 kW
76,10 kW
53,20 kW
50,00 kW
97,90 kW
87,20 kW
122,00 kW
103,00 kW

SHW
35.87 kW
33.57 kW

STEAM
40.57 kW
38.86 kW
-

50.39 kW
48.18 kW

58.12 kW
56.09 kW
-

96.91 kW
83.38 kW

97.29 kW
86.49 kW
-

149 kW
133.4 kW

145 kW
133.2 kW
-

Sound
pressure
dB(A)
48
46
49
47
50
48
54
52
55
53
56
54
56
49
58
51
59
52
56
50
57
51
58
52
54
47
55
46
56
44

HEATING - COOLING - SINGLE-PHASE motor


Model
4350
4400
4450
4500
4630

No. rows

Supply air velocity


Single-phase motor

Flow rate
m3/h

Air velocity
m/s

Throw (metres)
Wall

Direct
Direct
Direct
Direct

1640
2160
3025
4060

2.47 m/s
2.35 m/s
2.44 m/s
2.41 m/s

23
26
24
23

Capacity (kW)
Heating
Cooling
24,00 kW
4,78
32,60 kW
6,68
46,80 kW
10,1
61,70 kW
13,8

Direct

5960

2.39 m/s

21

93,50 kW

Sound pressure
dB(A)

21,4

30
48
45
54
51

ELECTRIC HEATING - SINGLE-PHASE motor


Model
4350
4400
4500

Supply air vel.


Single-phase
Direct
R3*
Direct
R3*
Direct
R3*
Direct
R3*

Flow rate
m3/h
2600
2360
4200
3914
7100
5700
6600
5380

Air velocity
m/s
3.92 m/s
3.56 m/s
4.57 m/s
4.26 m/s
4.22 m/s
3.39 m/s
3.92 m/s
3.20 m/s

Throw (metres)
Wall
22
18
27
24
28
26
26
24

Electric heating capacity (kW)


No. of stages
Capacity per stage
2.4 kW
9.6 kW
2
7.2 kW
5.4 kW
18.9 kW
2
13.5 kW
10.8 kW
28.8 kW
2
18 kW
Total

43.2 kW

14.4 kW x 3

Sound pressure
dB(A)
48
46
54
52
56
50
57
51

Specifications determined using the following information:

Hot water (LP HW):


Superheated water (HP SHW):
Steam (HP STEAM):
Cold water:
Air throw:

90-70C / 15C RT 50% RH


180-120C / 15C RT 50% RH
175C 8 bar / 15C RT 50% RH
7-12C / 25C RT 50% RH
* with JET+ diffuser for a residual velocity of 0.1 m/s
* defined with t ST/RT of 15C (heating) and 7C (cooling)
* with LP water or electric heating
Air velocity:
exiting JET+ diffuser
Sound pressure:
measured 5 metres from unit, directivity 2, attenuation of 22 dB
Direct: velocity obtained when wired directly to single-phase motor.
R3*: supply air velocity obtained with autotransformer set to 3. Other operating points (5 altogether)
can be provided on request by your CIAT representative using our technical selection software.
8

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

ELECTRIC
Use

MOTOR SPECIFICATIONS

Model

Motor

Rated current

Input power

1400

0.35 A

120 W

PV - 1000

0.15 A

70 W

GV -

1400

0.8 A

300 W

PV - 1000

0.6 A

200 W

GV -

1400

1.1 A

620 W

PV - 1000

0.6 A

430 W

GV -

1400

1.1 A

620 W

PV - 1000

0.63 A

380 W

GV -

1.3 A

590 W

PV - 750

0.64 A

400 W

Direct 1400

0.7 A

150 W

Direct 1400

1.3 A

300 W

Direct 1400

2.8 A

630 W

Direct 1400

2.65 A

600 W

4630

Direct 1000

2.00 A

450 W

4350

Direct 1000

0.3 A

70 W

Direct 1000

0.5 A

110 W

Direct 750

0.85 A

140 W

Direct 750

0.83 A

150 W

Direct 750

1.9 A

370 W

GV -

HEATING

4400

4450

4500

THREE-PHASE
230/400 V 50/60 Hz

4350

4630

4450
4500

4400
4450
4500

SINGLE-PHASE
230 V 50/60 Hz

4400

SINGLE-PHASE
230 V 50/60 Hz

COOLING

HEATING

4350

4630

COIL

Rotation
speed

1000

LP WATER COIL
HP OIL/WATER COIL

OTP

Class Operating temp.


-40C / +60C

44

YES
6.3 A - 165C

F
-40C / +70C

54

44

54

-40C / +60C
YES
6.3 A - 165C

-40C / +70C

44

54

40C / +60C
YES
6.3 A - 165C

40C / +70C

SPECIFICATIONS
4350

HP STEAM COIL

IP

Number of heating rows


Number of cooling rows
Coil capacity (L)
Connection diameter
Connection type
Operating pressure
Pressure test
Maximum temperature
Number of heating rows
Coil capacity (L)
Connection diameter
Connection type
Operating pressure
Pressure test

4400

0.68

1.18

1.66

1.19
33.7 mm

1
0.96

2
1.59

4450
3

2
3
1
3
2.28 1.38 2.27 3.22
2.18
1
Threaded unions 243 GCU F/M
16 bar
24 bar
110C

1.69
42.4 mm

Maximum temperature
Number of heating rows
Coil capacity (L)
Connection diameter
Connection type
Operating pressure
Pressure test
Maximum temperature

1
Weld-on smooth steel tube
16 bar
24 bar

4500
2
3.38

4630
3

4.55 2.97
1

2.66

4.7

6.4

3.69
42.4 mm

200C
0.97
26.9 mm

1.22
33.7 mm

1
Weld-on smooth steel tube
16 bar
24 bar
200C

1.95

2.86
48.3 mm

Stainless steel tubes or Sakafen coating are available upon request. Contact our sales network.

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

HELIOTHERME H4000

Heliotherme range

Heliotherme range

HELIOTHERME H4000
DIMENSIONS
B

Sizes

mm
A

4350
4400
4450
4500
4630

ASSEMBLY

Weight (kg)
1 row

2 rows

3 rows

460

713

286

101

21

23

25

555

767

286

142

29

31

33

618

880

286

142

38

40

42

714

985

336

142

48

51

54

874

1115

336

142

59

64

69

ACCESSORIES

A different assembly for each use.


RETURN AIR MODULE
Size

10

Codes

4350

440

7185105

4400

520

7185106

4450

600

7185107

4500

680

7185108

4630

840

7185110

220

Size

Codes

4350

1316

440

510

7185111

4400

1386

520

590

7185112

4450

1541

623

669

7185113

4500

1701

704

750

7185114

4630

2076

864

910

7185116

Size

Codes

4350

455

659

7185118

4400

535

739

7185120

4450

615

819

7185122

4500

695

899

7185123

4630

855

1059

7185125

Size

Codes

4350

585

455

788

7185127

4400

665

535

868

7185128

4450

745

615

949

7185129

4500

825

695

1029

7185131

4630

985

855

1189

7185132

Filter box (G1 filter in accordance with EN 779)


Prevents premature clogging of
exchanger coils
Not ductable

Indoor/outdoor return air duct with built-in filter


Adjusts the supply of fresh air to levels required by current
regulations and mixes it with return air. G1 filter.
Promotes the mixing of return air and supply air for better
comfort levels.

Outdoor air intake box with built-in filter


Adjusts the supply of fresh air to rooms to levels required
by current regulations.
Built-in G1 filter and connecting flange for cubic ducts.
Air inlet side configurable on site

2-channel mixing box with built-in filter


Adjusts the supply of fresh air to levels required by current
regulations and mixes it with return air.
Built-in G1 filter and connecting flange for cubic ducts.
Air inlet sides configurable on site

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

DIFFUSION MODULE

Codes

4350

750

700

300

7185133

4400

850

750

325

7185134

4450

970

850

350

7185135

4500

1100

970

375

7185136

4630

1250

1170

400

7185137

Size

Codes

4350

4400

178

555

522

7185138

4450

136

637

618

7185139

4500

132

740

714

7185140

4630

282

872

814

7185141

Size

Diffuser on door
Create an air curtain that limits heat loss
when doors are opened.

Diffuser for large spaces


Reduction cone for increasing the throw of
air streams

MOUNTING ACCESSORIES
Size

Codes

All

7181226

350 to 450

7181228

500 to 630

7181230

Size

Codes

4350 to 4450

7185142

Wall bracket

Additional kit for fastening on an I-beam


-

4500 and
4630

7185146

Codes

Ceiling bracket

DUCT ACCESSORIES
Size

443

7043051

4400

523

7043052

4450

603

7043053

4500

683

7043054

4630

843

7043055

Codes

4350

130

B
C

Size

438

7043033

4400

518

7043034

4450

598

7043035

4500

678

7043036

4630

838

7043037

4350

Antifreeze damper

125

B
C

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

Outdoor kit
Rain shield frame with bird screen, automatic
shutter and metal connection

11

HELIOTHERME H4000

Heliotherme range

Heliotherme range

HELIOTHERME H4000
ELECTRICAL

ACCESSORIES:
ELECTRICAL & USER SAFETY:
Codes

THREE-PHASE

SINGLE-PHASE

Use

0596142

0596147

Codes

H4350

7124708

H4400

7124709

H4450 and 4500

7124711

H4630

7124710

H4350

7124705

H4400

7124708

H4450 to 4630

7124709

Padlockable proximity switch


Available in a 1 or 2-speed version. Must be
placed at least 2 metres from any rotating
machinery (French standard IT 246, Art. 4-7-3,
and EC requirements)

Thermal-magnetic circuit breaker


All installations must be protected from
overcurrents and overvoltages (French standard
NFC 15-100)

THERMOSTATS:
Codes

IP30 indoor environment thermostat Single-phase installation

5201027

5201027: heating only or cooling only (RTR-E 6721)


Inductive cut-off capacity 4A

5201028

5201028: heating and cooling with manual toggle switch (RTR-E 6731)
Inductive cut-off capacity 2A

Codes

IP54 industrial environment thermostat Three-phase installation

7113335

7133335: 1 stage

7113336

7133336: 2 stages

AIR VELOCITY SELECTION:


Codes

LS/HS switch
For three-phase motor. Two speeds and off.

12

7169961

Codes

7166982

Autotransformer with selector switch (3.5 A)


Adjusts the voltage on single-phase motors with one variable speed to achieve up
to five supply air speeds.

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

HELIOTHERME H4000

Heliotherme range
SINGLE-PHASE HELIOTHERME

CONTROL:

SINGLE-PHASE Eco+ BOX UNIT RANGE

Unit description

Electronic air (FMA) and water (3-way valve) control for SINGLE-PHASE air heaters.

Proportional control system adjusts the supply air rates and coil water supply based on the difference between the indoor temperature (measured by the built-in sensor)
and the programmed temperature setpoint (summer or winter).

Built-in weekly timer for three operating modes: COMFORT, ECONOMY and FROST PROTECTION

Advantages:

Master/slave or independent control for total control of a set of HELIOTHERME units.

Economical, responsible management of your entire installation. Use the proportional control system to heat and cool
only when needed.

Front digital display for quick and easy viewing of the status of your HELIOTHERME units.

Extremely easy to configure without the need for technicians or programmers.

All-in-one solution. Simply plug it in and feel the effects!

Specifications:

Power supply: Single phase, 230 V, 50/60Hz

10 A rated current

IP50 housing

Digital display and adjustment keys on front

0-10 V outputs for valve control available

Built-in sensor

Optional remote sensor (length 15m)

Description

Codes

7184939

3/4 - 2.5 Kvs valve kit (H4351-4352-4401-4451)

B400410

3/4 - 4 Kvs valve kit (H4351-4402-4403-4452-4501)

B400411

112 - 6.3 Kvs valve kit (H4452-4501-4502-4631)

B400412

112 - 10 Kvs valve kit (H4632-4633)

B400413

Changeover thermostat (automatic summer/winter changeover)

7128892

220/24 Vac safety transformer (necessary for the electric supply


of the valve(s) servomotor(s) 0-10V

5203542

Remote sensor (length 15m)

7207381

SINGLE-PHASE Eco+ UNIT


(one unit controls up to three Heliotherme H4000s)

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

13

Heliotherme range
THREE-PHASE HELIOTHERME
BOX TRI ECO+ range

HELIOTHERME H4000

CONTROL:

(Manual with diagrams NA09.35)

DESCRIPTION
Complete PLUG & PLAY solution for air and/or water control for HELIOTHERME 4000 units equipped with
THREE-PHASE fan motor assemblies. Enables:
- automatic or manual selection of two air speeds on the three-phase fan motor assemblies and
proportional supply of water to the HELIOTHERME coils based on building heating demand.
- adjustment of heat and air flows according to room occupancy levels via a built-in timer with four operating
modes (Comfort, Economy, Frost Protection, Off).

ADVANTAGES
All the air heaters in a buildings HVAC system are controlled by a master controller that can control up to three BOX TRI
ECO+ slaves, each of which can themselves control three 3-phase HELIOTHERME 4000 units via one BOX TRI ECO+ BMR
(multiple junction box).
Air flows are adjusted automatically and water flows are adjusted proportionally on the HELIOTHERME units to meet heating
and cooling demand as closely as possible.
Supply air temperatures are controlled to maintain the necessary air throws. Comfort levels are also enhanced.
Spaces inside buildings are heated according to their occupancy levels.
All-in-one control solution for faster installation: no need to size and wire the electrical components (circuit breaker,
padlockable proximity switch, contactor, thermostat, timer, etc.).
Two user levels: USER (restricted access) and INSTALLER (full access) for greater simplicity, ease of use and security.

ELECTRICAL CHARACTERISTICS

Communication between master controller and slave unit(s) over a four-wire RS485 bus system
400 V/3-ph/Neutral BOX TRI ECO+ slave unit
IP55 (master controller) and IP65 (slave units and BMR) protection ratings
Built-in motor overload and user protections as required by French standard NF C 15-100

Codes

Master controller (built-in room sensor)


Can control up to three BOX TRI ECO+ slave units

7219774

BOX TRI ECO+ slave unit


Can control up to three 3-ph HELIOTHERME units

7218912

BMR multiple junction box for BOX TRI ECO+

7239492

4 valve kit - 2.5 Kvs (H4351-4352-4401-4451)

B400410

4 valve kit - 4 Kvs (H4353-4402-4403-4452-4501)

B400411

1 2 valve kit - 6.3 Kvs (H4452-4501-4502-4631)

B400412

112 valve kit - 10 Kvs (H4632-4633)

B400413

Remote sensor (length: 15 metres)

7207381

Changeover thermostat (automatic summer/winter changeover)

7128892

6P padlockable proximity switch for BOX TRI ECO+

0596147

Prices

3
3

14

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

HELIOTHERME H4000

Heliotherme range
THREE-PHASE HELIOTHERME

CONTROL (Manual with diagrams NA 09.35)

BOX TRI ECO+ range with fresh air control

DESCRIPTION
Complete PLUG & PLAY solution for air and/or water control with fresh air control for
HELIOTHERME 4000 units equipped with THREE-PHASE fan motor assemblies. Enables:
- automatic or manual selection of two air speeds on the three-phase fan motor
assemblies and proportional supply of water to the HELIOTHERME coils based on
building heating demand.
- choice of operation: fresh air only or mix with frost protection or 100% recirculated air.
- adjustment of heat, air flows and fresh air based on room occupancy levels via a builtin timer with five operating modes (Fresh air comfort, Return air comfort, Economy, Frost
protection, Off).

ADVANTAGES
All the air heaters in a buildings HVAC system are controlled by a master controller that can control up to three BOX TRI
ECO+ slave units).
Air flows are adjusted automatically and water flows are adjusted proportionally on the HELIOTHERME units to meet heating
and cooling demand as closely as possible.
The fresh air rates in buildings are controlled to meet prevailing requirements or are adjusted based on room
occupancy levels.
Supply air temperatures are controlled to maintain the necessary air throws. Comfort levels are also enhanced.
Spaces inside buildings are heated according to their occupancy levels.
All-in-one control solution for faster installation: no need to size and wire the electrical components (circuit breaker,
padlockable proximity switch, contactor, thermostat, timer, etc.
Two user levels: USER (restricted access) and INSTALLER (full access) for greater simplicity, ease of use and security.

ELECTRICAL

CHARACTERISTICS

Communication between master controller and slave unit(s) over a four-wire RS485 bus system
400 V/3-ph/Neutral BOX TRI ECO+ slave unit
IP55 (master controller) and IP65 (slave units and BMR) protection ratings
Built-in motor overload and user protections as required by French standard NF C 15-100

Codes

Master controller (built-in room sensor)


Can control up to three BOX TRI ECO+ slave units

7219774

BOX TRI ECO+ slave unit with fresh air control


Fresh air kit (includes a damper actuator and a frost protection thermostat)
3
4 valve kit - 2.5 Kvs (H4351-4352-4401-4451)
3
4 valve kit - 4 Kvs (H4353-4402-4403-4452-4501)
112 valve kit - 6.3 Kvs (H4452-4501-4502-4631)
112 valve kit - 10 Kvs (H4632-4633)
Remote sensor (length: 15 metres)
Changeover thermostat (automatic summer/winter changeover)

7218912
B400414
B400410
B400411
B400412
B400413
7207381
7128892

Price list

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

15

Heliotherme range
ALL-ELECTRIC HELIOTHERME

HELIOTHERME H4000
CONTROL

(Manual with diagrams NA09.36)

BOX ELEC ECO+ range

DESCRIPTION
Complete PLUG & PLAY solution for HELIOTHERME 4000 units equipped with electric heaters and
THREE-PHASE ROTOREX fan motor assemblies. Enables:
- automatic activation of electric heater stages in various combinations based on building heating
demand.
- operation of a fan delay on electric heaters when building heating is turned off
- adjustment of electric heaters according to room occupancy levels via a built-in 7-day programmable
timer with four operating modes (Off, Comfort, Economy, Frost Protection).

ADVANTAGES
The HELIOTHERME units are controlled by master controller which can control three BOX ELEC ECO+ slave units (each
slave unit controls a HELIOTHERME).
The electric heater stages are automatically activated in various combinations to meet heating demand as closely as
possible.
Compliance with safety requirements for buildings open to the public (French Articles CH 34/37) and EN 60204-1: the fan
delay and overload protections protect systems and buildings from the risk of fire.
Spaces inside buildings are heated according to their occupancy levels.
All-in-one control solution for faster installation: no need to size and wire the electrical components (circuit breaker,
padlockable proximity switch, contactor, thermostat, timer, etc.).
Individual display of the operating status of each HELIOTHERME (current operating mode, heater fault, motor fault, etc.)
Two user levels: USER (restricted access) and INSTALLER (full access) for greater simplicity, ease of use and security.

ELECTRICAL

CHARACTERISTICS

Identified 2 m wire inside BOX ELEC ECO+ slave unit for eacy connection with the HELIOTHERME.
Communication between master controller and slave unit(s) over a four-wire RS485 bus system
400 V/3-ph/Neutral BOX ELEC ECO+ slave unit
IP55 (master controller) and IP65 (slave units and BMR) protection ratings
Built-in motor overload and user protections as required by French low voltage (NF C 15-100) and fire protection standards;
Built-in padlockable proximity switch as required by the European machinery directive, CE standards, and French standard
NFS 61-932.

Codes

Master controller (built-in room sensor)


Can control up to three BOX ELEC ECO+ slave units

7219774

9.6 kW BOX ELEC ECO+ slave unit (for H4350 TRI TE)

7218907

18.9 kW BOX ELEC ECO+ slave unit (for H4400 TRI TE)

7218908

28.8 kW BOX ELEC ECO+ slave unit (for H4500 TRI TE)

7218910

43.2 kW BOX ELEC ECO+ slave unit (for H4500 TRI TE)

7218911

Remote sensor (length: 15 metres)

7207381

Prices

16

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

HELIOTHERME is also the solution for ATEX compliance


Ex II 2 G/D
II c 65C - 105C or 120 to 220C
EEx d/de IIB or IIC T4 to T6 IP 6X/5X T C
CIAT has put all its expertise and know-how into a special series of ATEX certified HELIOTHERME units.
They are identified by the following code: LCIE 03 ATEX 6392X.
This approval, issued by an independent external body, is your guarantee of complete compliance with the ATEX directives.
The HELIOTHERME ATEX range is certified for applications under the following conditions:

explosive atmospheres containing gases or dusts

Zone 1 or 2 areas

II B or II C explosion groups

T4 to T6 gas autoignition temperatures

low pressure water, superheated water, vapour, oil, compressed air, etc.

What does ATEX mean?


ATEX stands for explosive atmosphere. An explosive atmosphere is a mixture with air, under atmospheric conditions, of
flammable substances in the form of gases, vapours, mists or dusts in which, after ignition has occurred, combustion spreads to
the entire unburned mixture.
How are ATEX zones defined?
ATEX zones are determined based on the probability and duration of the occurence of an explosive atmosphere. This risk
analysis is used to define ATEX zones, explosion groups and maximum surface temperature classes. These atmospheres are
mainly found in such places as paint shops, metal processing operations, waste recycling plants and wood processing plants.
Who is responsible for defining ATEX zones?
Any operator of a production facility where an explosive atmosphere may occur must define the relevant ATEX zones, explosion
groups and temperature classes. By doing so, the operator will also be able to set up the necessary means of prevention
(communication, documentation, recommendations, etc.).

ZONE

Category

The explosive atmosphere:

20

occurs continuously, often and over extended periods: NOT APPLICABLE TO ANY CIAT PRODUCTS

21
22

1
2

occurs occasionally during normal use


occurs rarely and only for a short period

Gas (G)

Dust (D)

0
1
2

GASES EXPLOSION GROUPS AND TEMPERATURE CLASSES


Temperature class

T1

T2

T3

T4

T5

T6

Max. surface temperature

450C

300C

200C

135C

100C

85C

Acetone
Ammonia
Benzene
Acetic acid
Ethane
Ethyl acetate
Ethyl chloride
Methanol
Naphthalene
Phenol
Propane

i-Amyl actate
Butane
Butanol

Petrols
Diesels
Heating oils
Hexane

Acetaldehyde

Hydrogen sulphide

Ethylether

Explosion group

IIA

II B

Town gas

Ethylene

II C

Hydrogen

Acetylene

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

Carbon disulphide

17

HELIOTHERME H4000

Heliotherme range

Heliotherme range

HELIOTHERME H4000
LP WATER
Water / LP Oil
Standard version
Stainless steel options (supplement)
Casing
Single-phase - Single-phase Three-phase
Coil
Heating
Cooling
Heating
Cooling

Model

H4351
H4352
H4353
H4401
H4402
H4403
H4451
H4452
H4453
H4501
H4502
H4503
H4631
H4632
H4633

Code

7184359

7184346

B400030

Code

7184366

7184365

B400031

B400094

Code

7184375

7184379

H4501
H4631

18

B400094

B400095

7184384

B400039

B400097

Code

7184391

7184390

B400040

B400097

7184395

7184439

Code

7184360

B400041

B400097

B400098

7184367

B400048

B400100

7184388

7184392

B400049

B400100

Code

7184440

7184445

Code

7184446

B400050

B400100

B400101

7184448

B400057

B400103

7184493

7184496

B400058

B400103

7184500

7184449

Code

7184509

7184443

Code
Code

7184393

Code

7184501

B400059

B400103

B400104

7184510

B400066

B400106

Code

7184511

7184512

B400067

B400106

Code

7184514

7184491

7184516

B400068

B400106

B400107

OIL

&

STEAM

Superheated water / Oil


Standard
Stainless steel options
version
(supplement)
SINGLE-PHASE THREE-PHASE

H4401

B400032

7184387

Model

H4351

Code

7184372

Code

SUPERHEATED WATER / HP

Code

B400094

7192192

7192199

Coil

Casing

B400030

B400094

Steam
Stainless steel options
(supplement)

Standard
version

SINGLE-PHASE THREE-PHASE
7192204

7192209

Coil

Casing

B400033

B400094

Code

7192196

7192200

B400039

B400097

7192205

7192210

B400042

B400097

Code

7192197

7192201

B400057

B400103

7192206

7192226

B400060

B400103

Code

7192198

7192202

B400066

B400106

7192208

7192227

B400069

B400106

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A

ELECTRIC

HEATING
Electric
Model

H4350

Stainless steel
Casing

Standard version
Single-phase

Three-phase

Code

7192213

7192220

B400096

Code

7192214

7192222

B400099

Code

7192217

7192223

B400105

Code

7192218

7192228

B400105

9.6 kW

H4400

18.9 kW

28.8 kW

H4500
43.2 kW

Options available at additional cost


Size

Corrobloc motor
Single-phase
Code

B400119

Three-phase
B400121

3-ph, 400 V - 6P ATEX motor


II B - T4

II C - T4

II B - T5

II C - T6

B400252

B400256

B400254

B400258

B400260

B400264

B400262

B400266

B400268

B400272

B400270

B400274

B400276

B400280

B400278

B400282

350

Code

B400122

B400124

400

Code

B400125

B400127

450

Code

B400128

B400130

500

Code

B400131

B400133

630

AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE NA 09.643 A