786 Series

www.murata-ps.com

General Purpose Pulse Transformers

n Industry standard pinout


n Surface mount option
n UL 94 V-0 package materials
n Low profile
n Toroidal construction
n Fully encapsulated

DESCRIPTION
The 786 series is a comprehensive range of
general purpose pulse transformers. Common
applications include line coupling, matching or
isolating. The devices can also be used in small
isolated power supplies and also as commonmode chokes in filtering applications.

Surface-mount parts
The surface-mount (M suffix) products are not
recommended for new designs. For existing designs,
however, Murata Power Solutions will continue to
manufacture and fully support these parts.
For recommended alternatives please refer to the
786J Series datasheet.

Vs

pF

Vrms

67
200
500
1000
2000
4000
10000
67
200
500
1000
2000
4000
10000
67
200
500
1000
2000
4000
10000
67
200
500
1000
2000
4000
10000
67
200
500
1000
2000
4000
10000

4
6
10
15
20
28
56
4
6
10
15
20
28
56
4
6
10
15
20
28
56
4
6
10
15
20
28
56
4
6
10
15
20
28
56

0.19
0.20
0.25
0.29
0.47
0.47
0.86
0.11
0.17
0.27
0.35
0.60
0.71
0.71
0.41
0.49
0.65
0.76
0.99
1.61
1.64
0.30
0.65
1.07
1.13
1.53
1.98
3.83
1.21
3.64
6.86
11.9
16.0
37.7
44.5

8
14
22
35
49
78
121
12
19
32
47
72
116
167
4
9
13
20
29
50
72
7
12
20
35
47
64
72
3
5
7
10
16
20
19

0.17
0.25
0.34
0.45
0.60
0.84
1.30
0.18
0.24
0.34
0.46
0.66
0.92
1.34
0.18
0.25
0.34
0.46
0.60
0.85
1.23
0.20
0.25
0.36
0.48
0.63
0.88
1.33
0.17
0.24
0.34
0.45
0.60
0.87
1.33

Winding
Configuration

Isolation
Voltage

n 1kVrms isolation

Max.
DC
Resistance

n Primary inductance to 10mH

1:1
1:1
1:1
1:1
1:1
1:1
1:1
1:1:1
1:1:1
1:1:1
1:1:1
1:1:1
1:1:1
1:1:1
2:1
2:1
2:1
2:1
2:1
2:1
2:1
1CT:1
1CT:1
1CT:1
1CT:1
1CT:1
1CT:1
1CT:1
1CT:1CT
1CT:1CT
1CT:1CT
1CT:1CT
1CT:1CT
1CT:1CT
1CT:1CT

Typ.
Interwinding
Capacitance

n 4 Configurations

78601/4C
78601/3C
78601/2C
78601/8C
78601/1C
78601/16C
78601/9C
78602/4C
78602/3C
78602/2C
78602/8C
78602/1C
78602/16C
78602/9C
78604/4C
78604/3C
78604/2C
78604/8C
78604/1C
78604/16C
78604/9C
78613/4C
78613/3C
78613/2C
78613/8C
78613/1C
78613/16C
78613/9C
78615/4C
78615/3C
78615/2C
78615/8C
78615/1C
78615/16C
78615/9C

Typ.
Leakage
Inductance

n RoHS compliant

Turns
Ratio

Primary Min.
Volt-time
Product, Et

FEATURES

Order Code

Min.
Primary
Inductance

SELECTION GUIDE

1000

1000

1000

1000

1000

ORDER CODE DETAILS


Order Code
786XX/XC
786XX/XMC
786XX/XMC-R

Package Type
6 Pin DIL
6 Pin SM
6 Pin SM

Packaging Type
Tube
Tube
Tape & Reel

Quantity
50
50
500

ABSOLUTE MAXIMUM RATINGS


Operating free air temperature range
Storage temperature range

0C to 70C
-60C to 125C

SOLDERING INFORMATION1

For full details go to

For
full details go to
www.cd4power.com/rohs
www.murata-ps.com/rohs

Pin finish
Peak wave solder temperature
Peak reflow temperature2

Matte tin
300C for 10 seconds
220C

All specifications typical at TA=25C


1 For further information, please visit www.murata-ps.com/rohs
2 For higher temperature reflow variants see 786J series datasheet

www.murata-ps.com/support
KMP_786C_B07 Page 1 of 4

786 Series
General Purpose Pulse Transformers
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS

6 Pin SMD Package Style

6 Pin DIL Package Style

12.70 (0.5)

9.52
(0.375) Max.

9.0
(0.354)
Max.

9.52 (0.375)
Max.

9.0
(0.354)

78601/1C

78601/1MC

XYYWW

XYYWW

6.35
(0.25)

6.35
(0.25)

3.440.50
(0.1350.02)

0.30 (0.012)
0.20 (0.007)

0.30 (0.012)
0.20 (0.008)

10.16 (0.4)

5.08 (0.2)

0.63 (0.025)
0.53 (0.021)

0.90 (0.04)
2.54 (0.1)

0.63 (0.025)
0.53 (0.021)

Unless otherwise stated all dimensions in mm (inches)


0.25 (0.01). All pins on a 2.54 (0.1) pitch and within
0.25 (0.01) of true position.
Package Weight: 1.1g Typ.

RECOMMENDED FOOTPRINT DETAILS


6 Pin DIL

6 Pin SM

(0.10)
2.542.54
(0.10)

1.601.60
(0.06)
(0.06)

2.54 2.54
(0.10)(0.10)

2.542.54
(0.10)
(0.10)

+0.15
(0.006)
+0.15
(0.006)
1.20
(0.05)
1.20
(0.05)
-0.00
(0.000)
-0.000
(0.00)
1.001.00
(0.04)
(0.04)

11.50
11.50
(0.45)
(0.45)
Unless otherwise stated all dimensions in mm (inches)
0.25 (0.01). All pins on a 2.54 (0.1) pitch and within
0.25 (0.01) of true position.

WINDING CONFIGURATION - 6 PIN DIL/SMD (TOP VIEW)

1
1
2* Pri
3

Sec

6
5*
4

1
2
3

Pri
Sec 1
Sec 2

6
5
4

1
2
3

Pri

Sec

6
5*
4

1
2
3

Pri

Sec

6
5
4

* Pins only fitted on 786XX/XMC and 786XX/XMC-R variants.

www.murata-ps.com/support
KMP_786C_B07 Page 2 of 4

786 Series
General Purpose Pulse Transformers
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
60 (2.36) Min.

382 (15.039) Min.

23.9-27.4 (0.94-1.08)*

13.50 (0.53)
12.80 (0.50)
Leader section
400 (15.7) Min.
100 (3.9)
Min.

1.50 (0.059)
Min.

30.4
(1.20) Max.
Goods
enclosure
section
24.4 (0.96)
26.4 (1.04)

Trailer section
160 (6.3) Min.
Unless otherwise stated all
dimensions in mm (inches) 0.25 (0.01).

20.20 (0.80) Min.

* Includes flange distortion at outer edge.


Measured at hub.

TAPE OUTLINE DIMENSIONS

11.50 (0.453)

4.00 (0.157)

+0.004
+0.10
1.50 -0.00 (0.059 -0.000 )

2.00 (0.079)

XYYWW

78601/1C

+0.012
24.00 +0.30
-0.10 (0.945 -0.004 )

1.75 (0.069)

Cover tape

7.20 (0.283)

9.37 (0.369)

12.00 (0.472)

0.60 (0.024) Max.

Direction of unreeling

Unless otherwise stated all


dimensions in mm (inches) 0.25 (0.01).

www.murata-ps.com/support
KMP_786C_B07 Page 3 of 4

786 Series
General Purpose Pulse Transformers
TECHNICAL NOTES

TUBE OUTLINE DIMENSIONS

ISOLATION VOLTAGE

10.95
(0.43)
4.00 (0.16)
0.600.15
(0.0230.005)

12.95
(0.51)

5.50 (0.22)
3.80
(0.15)
15.70 (0.62)
Tube length: 4652 (18.30.08). Tube quantity: 50.
Tube material: Antistatic coated clear pvc.
Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01).

Murata Power Solutions, Inc.


11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED

Hi Pot Test, Flash Tested, Withstand Voltage, Proof Voltage, Dielectric Withstand
Voltage & Isolation Test Voltage are all terms
that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to
verify the integrity of that isolation.
All products in this series are 100% production
tested at their stated isolation voltage.
A question commonly asked is, What is the
continuous voltage that can be applied across
the part in normal operation?
For a part holding no specific agency approvals both input and output should normally be
maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test
voltage represents a measure of immunity to
transient voltages and the part should never
be used as an element of a safety isolation
system. The part could be expected to function
correctly with several hundred volts offset
applied continuously across the isolation barrier; but then the circuitry on both sides of the
barrier must be regarded as operating at an
unsafe voltage and further isolation/insulation
systems must form a barrier between these
circuits and any user-accessible circuitry according to safety standard requirements.

REPEATED HIGH-VOLTAGE
ISOLATION TESTING
It is well known that repeated high-voltage
isolation testing of a barrier component can
actually degrade isolation capability, to a
lesser or greater degree depending on materials, construction and environment. This
series has toroidal isolation transformers,
with no additional insulation between primary and secondary windings of enameled
wire. While parts can be expected to withstand several times the stated test voltage,
the isolation capability does depend on the
wire insulation. Any material, including this
enamel (typically polyurethane) is susceptible to eventual chemical degradation when
subject to very high applied voltages thus
implying that the number of tests should be
strictly limited. We therefore strongly advise
against repeated high voltage isolation testing, but if it is absolutely required, that the
voltage be reduced by 20% from specified
test voltage.
This consideration equally applies to agency
recognized parts rated for better than
functional isolation where the wire enamel
insulation is always supplemented by a
further insulation system of physical spacing
or barriers.

Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice. 2011 Murata Power Solutions, Inc.

www.murata-ps.com/support
KMP_786C_B07 Page 4 of 4

Você também pode gostar