Escolar Documentos
Profissional Documentos
Cultura Documentos
Thermalfluids Lab
Centrifugal Pump
TABLE OF CONTENTS
Page
Table of Contents
. 0
Title
.. 1
1. Objective .
.. 1
2. Introduction .
. 1-2
3. Theoretical Background
. 3-5
4. Apparatus
. 6-7
5. Experimental Procedure
8
6. Data and Results
. 9-11
7. Sample Calculation
12-13
8. Analysis Results
1415
9. Discussion
16-22
5
MEM554
Thermalfluids Lab
Centrifugal Pump
10. Conclusion
23-26
11. Appendix
..
27
12. References
.
28
OBJECTIVE
The objectives of this experiment are toobtain the performance characteristics of a centrifugal
pump at three different impeller speeds.
The performance characteristics of pump are:
2.
INTRODUCTION
A pump is a device used to move gases, liquids, or slurries. A pump moves liquids or
gases from lower pressure to higher pressure, and overcomes this difference in pressure by
adding energy to the system (such as a water system). A gas pump is generally called a
6
MEM554
Thermalfluids Lab
Centrifugal Pump
compressor.The earliest pump was described by Archimedes in the 3rd century BC and is
known as the Archimedes screw pump. Pumps work by using mechanical forces to push the
material, either by physically lifting, or by the force of compression.
Pumps fall into three categories: positive displacement, kinetic (centrifugal), and jet. Their
names describe the method for moving water.
i.
ii.
iii.
A eductor-jet pump is special type of pump without moving parts that uses the kinetic
energy of a fluid to increase the pressure of a second fluid.
A centrifugal pump is one of the simplest pieces of equipment. Its purpose is to convert
energy of an electric motor or engine into velocity or kinetic energy and then into pressure of
a fluid that is being pumped. The energy changes occur into two main parts of the pump, the
impeller and the volute. The impeller is the rotating part that converts driver energy into the
kinetic energy. The volute is the stationary part that converts the kinetic energy into pressure.
Liquid enters the pump suction and then the eye of the impeller. When the impeller rotates, it
spins the liquid sitting in the cavities between the vanes outward and imparts centrifugal
acceleration. As the liquid leaves the eye of the impeller a low pressure area is created at the
eye allowing more liquid to enter the pump inlet.
Centrifugal Pumps are classified into three general categories:
MEM554
Thermalfluids Lab
Centrifugal Pump
i.
ii.
iii.
3.
THEORY:
One of the most common radial-flow turbo machines is the centrifugal pump. The
type of pump has two main components: an impelleer attached to a rotating shaft and a
stationary casing (or housing) enclosing the impeller. Schematic diagram of basic elements of
centrifugal pump is as shown below.
Discharge
Impeller
8
MEM554
Thermalfluids Lab
Centrifugal Pump
Hub plate
Eye
Inflow
Blad
Z2
Z1
MEM554
Thermalfluids Lab
Centrifugal Pump
p p
= ( 2 1) /
z z
+ ( 2 1) +
(V 22V 21)
/ 2g
(1)
Typically the differences in elevations and velocities (between inlet and outlet) are so small
so that
hp
p p
= ( 2 1 ) / pg
The power,
Pf
Pf
gQ h p
(3)
Pf
(2)
/ W
W shaft
shaft
(4)
Where,
shaft
the shaft power, is the product of the Torque applied to the shaft and the
angular velocity, .
shaft
= Tshaft
(5)
10
MEM554
Thermalfluids Lab
Centrifugal Pump
Where
2 N
60
Typical performance curve for the axial centrifugal pump of a given size operating at constant
speed is shown below:
4. APPARATUS
The experimental set-up consists of:
I.
MEM554
Thermalfluids Lab
Centrifugal Pump
II.
Speed measurement
a) Pump motor speed measurements are made using digital tachometer.
Inlet
pressure
reading
Torque
reading
Valve
s
Dischar
ge
pressur
e
Motor
12
MEM554
Thermalfluids Lab
Centrifugal Pump
13
MEM554
Thermalfluids Lab
Centrifugal Pump
5. PROCEDURE
Preliminaries
1. Students will be adequately supervised
2. Pump discharge and suction valves is turn to fully open and motor speed control is
turn to zero.
3. The electrical supply and motor drive switch is switch on. Motor control knob is
adjusted slowly to around half way position. Ensure that there are no leaks in the
system. All gauges etcis checked. The motor speed is reduced back to zero. The
apparatus is ready for testing.
Actual Experiment
1. Suction valve is opened and discharge valve is closed. Speed control is adjusted to
50% and maximum pump speed
N1
is selected.
2. Discharge valve is fully open and allow water to circulate. The volume of flow is
indicated and suitable increments in flow are decided to give adequate sample points
(about 15 points between zero and maximum flow).
3. The discharge valve is closed (corresponding to no flow). Read all measurements
when the measured readings are ready.
4. Discharge valve is open slightly, to give the first increment in volume flow. Take the
measurements when readings are steady
5. Step 4 is repeated. The valve is fully open correspon to the final measurements.
6. The entire experiment is repeated at pump speed correspond to speed control position
of 75% and 100%.
14
MEM554
Thermalfluids Lab
Centrifugal Pump
7. SAMPLE CALCULATION
Sample calculation:
Constants:
= 1000 kg/m3
g = 9.81 m/s2
1 hp = 746 W
For N = 1439 rpm,
=
2 N
60
2 (1439)
60
= 150.69 rad/s
15
MEM554
Thermalfluids Lab
Centrifugal Pump
( P2P1 )
g
Output power=gQh
Efficiency , =
Output power
x 100
shaft
16
MEM554
Thermalfluids Lab
Centrifugal Pump
9. DISCUSSION
Nursyafawani Kasram Binti Mohd Hisham
2014802024
From the experiment, characteristics of a centrifugal pump ran at different speeds (N 1 = 1439
rpm, N2 = 2178 rpm and N3 = 2945 rpm) are observed and drawn in graphs. These
characteristics curves are essential in defining the properties of a pump, since only size and
shape cannot be sufficient to select a pump for certain purpose. Standard test were done
according to the procedures defined by the lab manual and characteristics curves are drawn as
shown in Figure 1, Figure 2 and Figure 3.
From the pump performance curves, it can be predicted that the maximum volume
flow rate through a pump occurs when its net head is zero, H = 0. This flow rate is called the
pumps free delivery. The free delivery condition is achieved when there is no flow restriction
at the pump inlet or outlet or when there is no load on the pump. At this operating point, Q is
large, but H is zero and the pumps efficiency is zero because the pump is doing no useful
work. At the other extreme, the shutoff head is the net head that occurs when the volume flow
rate is zero, Q = 0, and is achieved when the outlet port of the pump is blocked off. Under
this condition, H is large but Q is zero. The pumps efficiency is again zero because the pump
is doing no useful work. Between these two extremes, from shutoff to free delivery, the
pumps net head may increase from its shutoff value somewhat as the flow rate increases, but
H must eventually decrease to zero as the volume flow rate increases to its free delivery
value. The pumps efficiency will reaches its maximum value somewhere between the shutoff
condition and the free delivery condition; this operating point of maximum efficiency is
appropriately called the best efficiency point (BEP).
For output power and volume flow rate obtained from the experiment, it can be seen
from Table 1 to Table 3 that the increased number of value in volume flow rate due to water
height is increasing in the matter of time. While for output power, there are inclined and
declined values can be seen from the tables. By comparing all these three speeds, it can be
said that the higher speed used in the experiment, the bigger number of output power will be
produced.
17
MEM554
Thermalfluids Lab
Centrifugal Pump
The efficiency of the pump for each test increases to a certain point and then decreases as
shown in Figure 1 to Figure 3. This is because of the increasing frictional losses in the long
blade passages of these narrow impellers. Since impeller blade have finite thickness, an
impellers with too many blades leads to passage losses due to excessive flow and large skin
friction drag. Also, the efficiencies depend upon the design of the machine, shape of the blade
and, hence, the capacity handled. The value of the effectiveness of the experiment data is
increasing due to the increasing value of the speed. The higher value of efficiency will give
the better performance of the operated machine. To get the better efficiency, the rate of power
output and input must be bigger.
It can be concluded from the experiment that the pump with speed of N = 1439 rpm
has the best performance since its line of efficiency intersect both lines of head and BHP at
one point which is called the best efficiency point. It occurs at 0.19 m3/s with the efficiency of
28.5%. While, the other line of efficiency for N = 2178 rpm and also for N = 2945 rpm only
intersect with the line of head which it cannot produce the best efficiency point.
The error that may occur during the experiment is parallax error when taking the data
reading of water height and pressure value for inlet pressure. While adjusting the discharge
water pressure, the machine causes other apparatus, such as the discharge pipe to vibrate
extremely hard. This may be due to the material of pipe which it cannot absorb the vibration,
and a steel pipe is recommended in this situation.
18
MEM554
Thermalfluids Lab
Centrifugal Pump
19
MEM554
Thermalfluids Lab
Centrifugal Pump
After the result was drawn into graph, we could see that efficiency increase first and
decrease later as flow rate increasing, break horse power was directly proportional to flow
rate and pump head was inversely proportional to flow rate. Efficiencies depend upon the size
of the machine and, hence, the capacity handled. The larger the machine, the higher is the
efficiency. However, the higher value of efficiency will gives the best performance of
operated machine. The rate of power output and input must be bigger in order to get the better
efficiency.
Based on this experiment, it can be concluded pump which its speed of N = 1439 rpm
has the best performance because it has resulted the intersection of its line of efficiency with
the line of head and break horse power(bhp). The intersection line at this one point is known
as the best efficiency point of the pump. It intersects at the flow rate of 0.19 m 3/s where the
efficiency of 28.5%. Meanwhile, both of the pump where its speed are N= 2178 rpm and N =
2945 rpm cannot produce the best efficiency point since the line of efficiency just only
intersects with the line of head.
The efficiency of the system can be increased by several ways. The examples are by
increasing clearances as impellers reduce in size, by using smoother surface finish of the
pump and tube, power supplied to drive the pump and by increasing the power supplied to
drive the pump.
20
MEM554
Thermalfluids Lab
Centrifugal Pump
4 performance characteristics of the centrifugal pump which are pressure (head) jump, power
requirement, flow rate influence and pump speed influence.
Based on the result obtained, the graphs of pump performance were plotted by
varying the 3 different impeller speeds. From graph 1 with impeller speed 50% (1439rpm),
the water head decrease when volume flow rate increase. Theoretically, if the total head at the
zero flow rate is the maximum head and also called the shut-off head, the total head decreases
as the flow increase. The trend of the graph BHP against volume flow rate showed the
increment. Theoretically, the trend of BHP should be decrease. There is some error during
conducting this experiment that influences the different between experimental result and the
theoretical. The relation between torque and BHP is donated by the equation (BHP=T x ).
For the graph efficiency against volume flow rate, the efficiency increase as the flow rate
increase. After the efficiency reached the peak, the efficiency is slightly decreased as the flow
rate increase. The best efficiency point recorded is 34.7% which is correspond with BHP at
24.2 hp and head at 432.2 m.
From the graph 2 (speed at 2178 rpm) for the water head against volume flow rate, the
trend showed that the decrement of the water head as the volume flow rate decreased. The
graph of BHP was not satisfied according to the theory. Based on the graph of BHP against
flow rate, the BHP increased as the flow rate increased. The best efficiency point recorded is
44.8% which is correspond with BHP at 70.3 hp and head at 1144.8 m. By comparing the
efficiency between impeller speed 1439 rpm and 2178 rpm, the efficiency of impeller speed
2178 rpm is greater than the impeller speed 1439 rpm.
From the graph 3 with impeller speed 2945 rpm, the head decreased as the volume
flow rate increased. The BHP also increased when the volume flow rate increased. The trend
of graph of pump efficiency against volume flow rate showed the increment and decrement.
The best efficiency point recorded is 51% which is correspond with BHP at 165.4 hp and
head at 2208m. By comparing the pump efficiency of the 3 different speeds, the impeller
21
MEM554
Thermalfluids Lab
Centrifugal Pump
speed with 2945 rpm showed the highest pump efficiency compared to others. We can say
that the efficiency increased as the impeller speeds increase.
There some errors influenced the result obtained from the experiment. Firstly, the
parallax error occurred when the observer taking the reading. Secondly, is the equipment
problem also influenced the result obtained.
MEM554
Thermalfluids Lab
Centrifugal Pump
head will increase. But, for the water head, it shows the decrease value. Each speed of the
pump gives the different value of the result. Beside that we can know the efficiency of the
pump sudden drop as the increasing of the volume flow rate. From the pump performance
curves, it can be predicted that the maximum volume flow rate through a pump occurs when
its net head is zero, H = 0. This flow rate is called the pumps free delivery. The free delivery
condition is achieved when there is no flow restriction at the pump inlet or outlet or when
there is no load on the pump
From the Figure 1 which is the graph of Pump Performance Curves for N =
1439 rpm, it can be said that at this speed the pump has its best
performance. This is because its line of efficiency intersect with both lines
of head and BHP at one point. This point is called the best efficiency point.
We make a straight line across this point to get the value and we found
that its occur at 0.19 m3/s with the calculated efficiency is 28.5%. The other line of
efficiency for N=2178 rpm and N=2945 rpm onlu intersect with line head so it cannot
produce the best efficiency point
When we want to increase the efficiency of the system we must choose the backwardinclined blades centrifugal pump instead of radial blades or forward inclined blades
centrifugal pump.
There were some error occur while do the experiment and this affect the calculation
result of the experiment. The error happen such as below:
-
Parallax error
o This error occur when the observer take the reading of the value for the
equipment in the experiment.
o The wrong sight will little bit affect the reading of the experiment data.
Equipment problem
o The error of the equipment also affect the result of calculation and this will
make the error for the data later.
Make sure the observer eye is in the right way in order to take the reading of the data
to avoid any error occur.
Ensure that all the equipment in the good condition before start the experiment.
Make sure all the safety aspects have followed while do the experiment.
23
MEM554
Thermalfluids Lab
Centrifugal Pump
10. CONCLUSION
Nursyafawani Kasram Binti Mohd Hisham
2014802024
From the experiment, the characteristics of this pump which is the efficiency, brake
horsepower and the head can be defined by using three different speeds of pump. Based on
the graph obtained from the data result, it can be seen that the entire graph are incline at first
and then slowly it started to decline.
However, it is to be noted that some of the value of readings obtained may be
inaccurate due to certain errors that occurred during the experiment such as parallax error and
the error due to the apparatus itself. Yet it still leads and produced the expected results
accordingly and as required. Thus, the objective of this experiment is achieved in order to
define any centrifugal pump characteristics.
Last but not least, it can be concluded that the best performance of this centrifugal
pump to operate is at speed N 1 = 1439 rpm since it produced the best efficiency point at 0.19
m3/s with the efficiency of 28.5%. While, when the pump was operated at the other two
speeds, it does not produce the best efficiency point.
24
MEM554
Thermalfluids Lab
Centrifugal Pump
increasing of flow rate. Meanwhile, the head, H approximately constant at low discharge and
then drop as flow rate increases for a given speed and impeller size. The highest efficiency of
the pump is the best condition for the pump to operate. Thus, performance curves of the type
are very important to the engineer as possible for the selection of pumps for a particular flow
system. In order to select a pump for a particular application, it is necessary to utilize both the
system curve, as determined by the system equation, and the pump performance curve.
Besides, the horsepower required to drive the pump rises monotonically with the flow rate.
Lastly, we can said that the experiment is achieved its objective to obtain and analyze
the performance characteristic of a centrifugal pump operating at a given impeller speed since
it produced the best efficiency point at 0.19m3/s with the efficiency of 28.5% by centrifugal
pump speed of N= 1439 rpm
25
MEM554
Thermalfluids Lab
Centrifugal Pump
26
MEM554
Thermalfluids Lab
Centrifugal Pump
As a conclusion, we can say that the objective of this experiment which to obtain
performance characteristics for a centrifugal pump of variable speed operating at 3 different
impeller speeds based on the pump characteristics included pressure (head) jump, power
requirement, flow rate influence and pump fluid influence had achieved. We also study that
all these characteristics will affect its efficiency. However, it is to be noted that, some of the
value of readings obtained may be inaccurate due to certain errors that occurred during the
experiment as the parallax error and equipment problem. The highest efficiency of the pump
is the best condition for the pump to operate.
This centrifugal pump will operate at its best performance is at speed N=1439 rpm. At
this speed it produced the best efficiency which is 28.5% at point 0.19 m3/s. While, when the
pump operate at other two different speed , it does not produce best efficiency point.
27
MEM554
Thermalfluids Lab
Centrifugal Pump
11.0 APPENDIX
12.0 REFERENCES
1. FLUID MECHANICS Fundamentals and Application, Yunus A. Cengel & John
M.Cimbala, McGraw Hill.
2. INTRODUCTION TO FLUID MECHANICS, Robert W. Fox, Alan McDonald, Second
Edition, John Wiley & Sons.
3. Working of Centrifugal Pump. http://www.learnengineering.org/2014/01/centrifugalhydraulic-pumps.html. (Retrieved on 23 October 2015)
4. Centrifugal Pump Principles. http://www.thomasnet.com/articles/pumps-valvesaccessories/centrifugal-principles. (Retrieved on 23 October 2015)
5. Understanding pump performance curve. http://www.progressivedairy.com/index.php?
option=com_content&id=10280:understanding-pump-performancecurves&Itemid=121. (Retrieved on 23 October 2015)
6.
System
Curve
and
Pump
Performance
Curve.
http://www.engineeringtoolbox.com/pump-system-curves-d_635.html. (Retrieved on 24
October 2015)
7. System
curve
and
pump
performance
curve.
http://www.engineeringtoolbox.com/pump-system-curves-d_635.html. (retrieved on 24
October 2015)
28
MEM554
Thermalfluids Lab
Centrifugal Pump
29