Você está na página 1de 71

T

Halogen free &


Mud resistant Offshore cable
NEK-606 (2004)

IEC 60092-350, 353, 354, 376

Total Solution of Marine Cable

OFFSHORE CABLE

TMC, a marine cable company representing korea makes happy technology.


In the fast-changing global era, when companies are repeating challenges and setbacks TMC has grown continuously
creating a new paradigm in the marine cable industry in Korea.
Since establishment in 1991, we have been involved in marine and other special cable business.
TMC started to produce indoor optical fiber cables in 2000, and in 2005, completed the new factory in Ipjang,
giving us the grandiosity of a company that is the biggest of its kind in Korea.
TMC has acquired certificates from 9 classification societies around the world, and exports to many countries.
A corporation marching toward the future through continuous R&D, best quality and customer service!
Becoming the best brand in the world based on the management philosophy.
That is the dream and vision of TMC.

02

Offshore Cable

Company
History

Certificates

July.,1991

Establishment as Seojin Industry Co., Ltd.

Dec., 1998

ISO 9001 Certification by LRQA

May., 2004

ISO 14001 Certification by LRQA

Mar., 2005

Changed the name of company to TMC Co., Ltd.

Mar., 2006

Selected as a supplier for DSME, Agbami FPSO Project

May., 2006

Selected as Excellent Supplier for Hyundai Mipo Dockyard Co., Ltd.

Mar., 2007

Received the high quality supplier Certification by DSME.

Aug., 2007

Korean world-class product award 2007

Nov., 2007

Award the 700 million dollars export tower

Received Type Approval Certification for the Shipboard Cables by


9 Classification (ABS, BV, CCS, DNV, GL, KR, LR, NK, RINA)
Received Type Approval Certification for the NEK-606(2004)
Off-shore Cables by ABS, DNV, LR
Listed by ETL & Received Type Approval Certification by ABS for the
Off-shore Cables
Received Type Approval Certification for the PassengerShip Cables by
ABS, DNV, LR, CCS
Received Patent of Paint Resistant Shipboard Cable
( Patent Number 10-0627241)
Listed by ETL & Received Type Approval certification by ABC and DNV
for the IEEE 1580 Type P Cables
Received Type Approval Certification for the LNG Carrier Cables by
ABS, DNV, LR
Received Gost-R certification for the NEK-606(2004) Off-shore Cables
by GOSSTANDART

Offshore Cable

03

CODE DESIGNATION

Materials

Insulation

Fire resistant tape+insulation (Halogen-free)


Ethylene propylene rubber - EPR
Cross-linked polyethylene XLPE
Thermoplastic compound (Halogen-free)
Halogen-free thermoset compound or EVA
Bedding/Inner covering or taping (Halogen-free)
Screen (poss. with PE or PP)
No armour
Copper wire braid (Tinned or bare)
Bronze wire braid
Galvanized steel wire braid
Thermoplastic compound (Halogen-free) SHF1
Halogen-free thermoset compound, SHF2
Halogen-free mud resistant thermoset
compound, SHF Mud
Halogen-free mud resistant thermoset compound

B
R
T
I
U

Bedding/
inner covering
inner sheath

X
O
B
C
I

Individual screen
Collective screen
Individual & Collevtive screen

EXAMPLE

0.6/1kV BFOU

Fire resisting layer + insulation(EPR)

Armor(Copper)

04

Offshore Cable

Sheath(SHF2 or SHF mud)

I
U
U

Added abbreviation

Voltage

Outer sheath

F
Y

Note). QFCB cables only

(i)
(c)
(i & c)

Armor/
screen

Inner covering(HFC)

NEK-606 (2004), IEC 60092-350, 353, 354, 376

INDEX

Materials

Designation

Page

3.6/6kV RFOU, RFBU, RFCU


HV power cable

Flame retardant

6/10kV RFOU, RFBU, RFCU

06 ~10

8.7/15kV RFOU, RFBU, RFCU


Flame retardant
LV power &
lighting cable
Fire resistance

Flame retardant
Instrumentation &
Communication cable
Fire resistance

Earthing &
Bonding wire
VFD cable

0.6/1kV RFOU, RFBU, RFCU

11 ~ 15

0.6/1kV RU

16 ~ 19

0.6/1kV BFOU, BFBU, BFCU

20 ~ 23

0.6/1kV BU

24 ~ 27

250V RFOU(c), RFBU(c), RFCU(c)

28 ~ 31

250V RFOU(i), RFBU(i), RFCU(i)

32 ~ 34

250V RFOU(i&c), RFBU(i&c), RFCU(i&c)

35 ~ 37

250V BFOU(c) , BFBU(c), BFCU(c)

38 ~ 40

250V BFOU(i) , BFBU(i), BFCU(i)

41 ~ 43

250V BFOU(i&c), BFBU(i&c), BFCU(i&c)

44 ~ 46

0.6/1kV UX
Flame retardant

47 ~ 48

0.6/1kV RX

Flame retardant

0.6/1kV(1.8/3kV) RFOU(VFD)

49 ~ 51

Fire resistance

0.6/1kV(1.8/3kV) BFOU(VFD)

52 ~ 53
54 ~ 71

Technical information

[NEK 606 Cable type code]


Cable type code
Designation

H/F

H/F & M/R

Cable type code


Designation

H/F

H/F & M/R

3.6/6kV RFOU

P2

P2/P9

0.6/1kV BU

P17

6/10kV RFOU

P3

P3/P10

0.6/1kV UX

P15

8.7/15kV RFOU

P4

P4/P11

250V RFOU(i)

S1

S1/S5

0.6/1kV RFOU

P1

P1/P8

250V RFOU(c)

S2

S2/S6

0.6/1kV BFOU

P5

P5/P12

250V BFOU(i)

S3

S3/S7

0.6/1kV RU

P18

250V BFOU(c)

S4

S4/S8

Note.
- H/F : Halogen free cable
- H/F & M/R : Halogen free & Mud resistant cable

Offshore Cable

05

HV Power Cable

HV Power Cable

3.6/6kV RFOU, RFBU, RFCU


6/10kV RFOU, RFBU, RFCU
8.7/15kV RFOU, RFBU, RFCU

06 ~ 10

HV Power Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE DESIGNATION (P2, P3, P4, P2/P9, P3/P10, P4/P11)


3.6/6kV RFOU, RFBU, RFCU

LV Power & Lighting Cable

6/10kV RFOU, RFBU, RFCU


8.7/15kV RFOU, RFBU, RFCU

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-354

- Flame retardant

: IEC 60332-1 &


: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581
Earthing & Bonding wire

- Halogen content

Instrumentation &
Communication Cable

IEC 60332-3 Category A

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Conductor screen
Semi-conducting layer (tape / compound)
3. Insulation
R
EPR as per IEC 60092-351
- Non-metallic part : Semi-conducting layer (tape / compound)

4. Insulation screen

- Metallic part : Copper wire braid


VFD Cable

- A suitable separator tape(s) may be applied over the metallic part


- Three metallic braided conductors shall be cabled.

5. Cabling

- Flame retardant & non-hygroscopic fillers may be used.

7. Armor
8. Sheath
9. Core identification

F
Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) - A suitable separator tape(s) may be applied under/over the armor
U

Technical Information

6/10kV RFOU

- Suitable tape(s) may be applied on the cabled core.

6. Inner covering

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Red
3C : Black, White, Red

Note.
Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

07

HV Power Cable
CABLE TYPE : 3.6/6kV RFOU, 3.6/6kV RFBU
No. of
Cores
No.

3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

08

Conductor
Nominal
Area
mm2
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
10
16
25
35
50
70
95
120
150
185
240
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Offshore Cable

Strand

Dia.

No. / mm
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
61 / 2.90
61 / 3.20
91 / 3.00
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7/ 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
60 / 2.25
37 / 2.03

mm
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
26.10
28.80
33.00
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21

Thickness
of
Insulation
mm
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
3.2
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.5
1.0
2.5
1.2
2.5
1.2
2.5
1.2
2.5
1.4
2.5
1.4
2.5
1.6
2.5
1.6
2.6
1.6

Nominal
dia.
inner
covering
mm
15.7
16.7
18.0
19.2
20.5
22.3
24.2
25.8
27.8
29.6
32.5
35.7
39.9
43.0
47.2
31.9
34.1
36.9
39.9
42.7
46.5
51.0
54.5
57.9
61.8
68.5
36.9

Overall diameter
Nominal

Tolerance

Cable
Weight
kg/km
740
850
1,000
1,160
1,340
1,630
1,980
2,290
2,680
3,130
3,940
4,800
6,050
7,090
8,810
2,360
2,740
3,280
3,860
4,500
5,520
6,770
7,910
9,080
10,630
13,190
3,460

Conductor Current Carrying


Resistance
Capacity
(at 20C) (Max.) (Max.) (at 45C)
/km
A
1.840
71
1.160
95
0.734
125
0.529
155
0.391
190
0.270
240
0.195
290
0.154
340
0.126
385
0.100
440
0.0762
520
0.0607
590
0.0475
670
0.0369
720
0.0286
780
1.840
50
1.160
67
0.734
89
0.529
105
0.391
135
0.270
170
0.195
205
0.154
240
0.126
270
0.100
305
0.0762
365
0.734
89

mm
21.0
22.2
23.5
24.9
26.2
28.2
30.3
31.9
34.1
36.1
39.7
43.1
47.7
51.0
55.6
39.1
41.5
44.5
47.7
50.7
54.9
59.6
63.5
67.1
71.4
78.5
44.5

mm
1.1
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.7
1.7
1.9
2.0
2.2
2.3
2.5
1.9
2.0
2.1
2.2
2.3
2.5
2.7
2.8
3.0
3.2
3.4
2.1

40.5

48.3

2.2

4,180

0.529

105

43.0

51.0

2.3

4,800

0.391

135

47.0

55.4

2.5

5,930

0.270

170

51.8

60.6

2.7

7,350

0.195

205

55.8

64.8

2.9

8,710

0.154

240

59.8

69.2

3.1

10,220

0.126

270

63.8

73.6

3.2

11,830

0.100

305

70.1

80.3

3.5

14,540

0.0762

365

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 6/10kV RFOU, 6/10kV RFBU

3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03

6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21

3.4
1.0
3.4
1.2
3.4
1.2
3.4
1.2
3.4
1.4
3.4
1.4
3.4
1.6
3.4
1.6
3.4
1.6

Tolerance

kg/km
960
1,130
1,280
1,480
1,770
2,130
2,500
2,860
3,410
4,220
4,960
6,140
7,140
8,870
3,230
3,820
4,370
5,040
6,140
7,400
8,540
9,780
11,410
14,240

Conductor Current Carrying


Resistance
Capacity
(at 20C) (Max.) (Max.) (at 45C)
/km
A
1.160
95
0.734
125
0.529
155
0.391
190
0.270
240
0.195
290
0.154
340
0.126
385
0.100
440
0.0762
520
0.0607
590
0.0475
670
0.0369
720
0.0286
780
1.160
67
0.734
89
0.529
105
0.391
135
0.270
170
0.195
205
0.154
240
0.126
270
0.100
305
0.0762
365

mm
24.0
25.5
26.7
28.2
30.0
32.1
34.3
36.1
38.6
41.9
44.5
48.5
51.4
56.0
46.0
49.2
51.9
54.9
59.4
63.9
67.6
71.4
75.9
83.2

mm
1.3
1.3
1.4
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.1
2.2
2.4
2.5
2.1
2.3
2.4
2.5
2.7
2.9
3.0
3.2
3.3
3.6

41.2

49.2

2.3

4,020

0.734

89

44.0

52.2

2.4

4,680

0.529

105

46.5

54.9

2.5

5,320

0.391

135

50.9

59.5

2.7

6,520

0.270

170

55.4

64.4

2.9

7,940

0.195

205

59.2

68.6

3.0

9,340

0.154

240

63.8

73.6

3.2

10,990

0.126

270

67.3

77.3

3.4

12,520

0.100

305

74.0

84.6

3.7

15,560

0.0762

365

Offshore Cable

HV Power Cable

mm
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
26.10
28.80
33.00
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25

Nominal

Cable
Weight

LV Power & Lighting Cable

No. / mm
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
61 / 2.90
61 / 3.20
91 / 3.00
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25

Overall diameter

Instrumentation &
Communication Cable

Dia.

Nominal
dia.
inner
covering
mm
18.5
19.8
21.0
22.3
24.1
26.0
28.0
29.6
31.4
34.5
36.9
40.7
43.4
47.6
38.4
41.2
43.7
46.5
50.8
54.9
58.4
61.8
66.1
72.8

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

VFD Cable

No.

Conductor
Nominal
Area
mm2
16
25
35
50
70
95
120
150
185
240
300
400
500
630
16
25
35
50
70
95
120
150
185
240

Technical Information

No. of
Cores

09

HV Power Cable
CABLE TYPE : 8.7/15kV RFOU, 8.7/15kV RFBU
No. of
Cores
No.

3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

10

Conductor
Nominal
Area
mm2
25
35
50
70
95
120
150
185
240
300
400
500
630
25
35
50
70
95
120
150
185
240
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Offshore Cable

Strand

Dia.

No. / mm
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
61 / 2.90
61 / 3.20
91 / 3.00
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03

mm
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
26.10
28.80
33.00
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21

Thickness
of
Insulation
mm
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
1.0
4.5
1.2
4.5
1.2
4.5
1.2
4.5
1.4
4.5
1.4
4.5
1.6
4.5
1.6
4.5
1.6

Nominal
dia.
inner
covering
mm
22.0
23.2
24.5
26.3
28.6
30.2
31.8
33.6
36.7
39.5
42.9
45.6
50.2
45.9
48.9
51.7
55.6
59.7
63.1
67.0
70.8
77.5
45.9

Overall diameter
Nominal

Tolerance

Cable
Weight

Conductor Current Carrying


Resistance
Capacity
(at 20C) (Max.) (Max.) (at 45C)
/km
A
0.734
125
0.529
155
0.391
190
0.270
240
0.195
290
0.154
340
0.126
385
0.100
440
0.0762
520
0.0607
590
0.0475
670
0.0369
720
0.0286
780
0.734
89
0.529
105
0.391
135
0.270
170
0.195
205
0.154
240
0.126
270
0.100
305
0.0762
365
0.734
89

mm
27.9
29.1
30.6
32.4
34.9
37.2
39.0
40.8
44.3
47.3
50.9
53.8
58.8
54.1
57.5
60.5
64.6
69.1
72.7
77.0
81.0
88.3
54.1

mm
1.4
1.5
1.5
1.6
1.7
1.8
1.9
1.9
2.1
2.2
2.3
2.5
2.7
2.5
2.6
2.7
2.9
3.1
3.2
3.4
3.5
3.8
2.5

kg/km
1,300
1,460
1,660
1,960
2,370
2,810
3,180
3,630
4,490
5,290
6,450
7,460
9,270
4,430
5,110
5,810
6,900
8,210
9,380
10,750
12,330
15,260
4,670

48.9

57.5

2.6

5,420

0.529

105

51.9

60.5

2.7

6,140

0.391

135

55.6

64.6

2.9

7,320

0.270

170

59.7

69.1

3.1

8,730

0.195

205

63.9

73.7

3.2

10,250

0.154

240

68.0

78.0

3.4

11,830

0.126

270

71.5

81.9

3.6

13,430

0.100

305

78.3

89.1

3.9

16,540

0.0762

365

LV Power & Lighting Cable

HV Power Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

0.6/1kV RU

16 ~ 19

0.6/1kV BFOU, BFBU, BFCU

20 ~ 23

0.6/1kV BU

24 ~ 27
VFD Cable

11 ~ 15

Technical Information

0.6/1kV RFOU, RFBU, RFCU

Earthing & Bonding wire

Instrumentation &
Communication Cable

LV Power & Lighting Cable

LV Power & Lighting Cable

CABLE DESIGNATION (P1, P1/P8)


0.6/1kV RFOU, RFBU, RFCU

APPLICATION STANDARD
- Design guide

: NEK-606& IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Classification
1. Conductor
2. Insulation

Construction detail

Code

Stranded tinned annealed copper wires as per IEC 60228, Class 2

EPR as per IEC 60092-351


- Insulated cores shall be cabled.

3. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

4. Inner covering
5. Armor

0.6/1kV RFOU

6. Sheath

F Flame retardant halogen free thermoset compound


O - Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) - A suitable separator tape(s) may be applied under/over the armor
U

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Black

No. of cores

7. Core identification

Without earth core

With earth core

1C

Black or Off-white

2C

Black, White

3C / 2C + E

Black, White, Red

Black, White, G/Y

4C / 3C + E

Black, White, Red, Blue

Black, White, Red, G/Y

5C / 4C+E

Black No. on white insulation Black, White, Red, Blue, G/Y

6C and over Black No. on white insulation Black No. on white insulation, G/Y

Note.
Flexible cable (Class5 Conductor) can be supplied

12

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV RFOU, 0.6/1kV RFBU

2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth

Tolerance

mm
10.4
10.8
11.4
12.1
13.1
14.1
16.1
17.5
19.2
21.2
23.7
25.5
27.5
29.9
33.4
37.3
14.5
15.3
16.5
17.7
19.9
21.9
25.9
28.5
32.1
37.0
42.0
45.8
50.2
55.0
62.0
68.0
15.1
15.9
17.4
18.5
20.9
23.2
26.8

mm
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.4
1.5
1.6
1.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.4
1.6
1.8
2.0
2.1
2.3
2.5
2.8
3.0
0.9
0.9
1.0
1.0
1.1
1.2
1.4

kg/km
170
190
220
260
320
400
550
690
860
1,120
1,450
1,750
2,080
2,530
3,220
4,060
320
370
440
530
690
890
1,280
1,610
2,060
2,840
3,740
4,520
5,450
6,640
8,500
10,370
360
410
51.
610
820
1,080
1,460

23.6

29.5

1.5

1,870

27.2

33.5

1.6

2,370

31.4

38.6

1.8

3,260

36.2

43.8

2.1

4,280

40.0

47.8

2.2

5,260

44.2

52.4

2.4

6,430

49.2

57.8

2.6

7,730

55.7

64.7

2.9

9,800

Conductor
Resistance
(at 20C) (Max.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.076
0.154

Insulation Current Carrying


Capacity
Resistance
(at 20C)(Min,) (Max.) (at 45C)
M /km
A
1,300
21
1,100
30
920
40
790
51
640
71
530
95
510
125
440
155
440
190
370
240
360
290
320
340
330
385
330
440
310
520
310
590
1,300
18
1,100
25
920
34
790
43
640
60
530
81
510
105
440
135
440
165
370
200
360
249
320
288
330
331
330
377
310
444
310
511
1,300
15
1,110
21
930
29
790
36
640
50
530
67
510
89
530
440
105
510
440
135
510
380
170
440
370
205
440
330
240
380
330
270
370
330
305
370
320
365
330

Offshore Cable

HV Power Cable

mm
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.56
2.01
2.55
3.12
4.05
5.10
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21

Nominal

Cable
Weight

LV Power & Lighting Cable

No. / mm
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7/ 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03

Overall diameter

Instrumentation &
Communication Cable

Dia.

Nominal
dia.
inner
covering
mm
5.9
6.3
6.9
7.4
8.4
9.4
11.2
12.4
14.1
15.9
18.2
19.8
21.8
24.0
27.1
30.3
9.6
10.4
11.6
12.6
14.6
16.6
20.2
22.6
26.0
30.0
34.6
38.2
42.2
46.6
53.2
58.8
10.2
11.0
12.3
13.4
15.6
17.7
21.1

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

VFD Cable

No.

Conductor
Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Technical Information

No. of
Cores

13

LV Power & Lighting Cable


CABLE TYPE : 0.6/1kV RFOU, 0.6/1kV RFBU, 0.6/1kV RFCU
No. of
Cores
No.

3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

14

Conductor
Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

Offshore Cable

Strand

Dia.

No. / mm
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 1.70
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37/ 2.52
61 /2.25
61 / 2.52

mm
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
5.10
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4

Nominal
dia.
inner
covering
mm
10.2
11.0
12.3
13.4
15.6
17.7
21.6
24.2
28.2
32.1
37.1
40.9
45.2
50.4
57.1
63.1
19.6
22.9

Overall diameter
Nominal

Tolerance

Cable
Weight

mm
15.1
15.9
17.4
18.5
20.9
23.2
27.3
30.3
34.5
39.3
44.7
48.7
53.4
59.0
66.3
72.7
25.3
28.8

mm
0.9
0.9
1.0
1.0
1.1
1.2
1.4
1.5
1.7
1.9
2.1
2.2
2.4
2.7
3.0
3.2
1.3
1.5

kg/km
360
410
510
610
820
1,080
1,570
2,000
2,610
3,570
4,730
5,730
6,930
8,540
10,930
13,380
1,330
1,790

26.1

32.2

1.6

2,350

29.7

36.2

1.7

2,950

33.8

41.2

1.9

4,020

39.4

47.2

2.2

5,360

43.3

51.3

2.4

6,560

48.7

57.3

2.6

8,170

52.8

61.6

2.8

9,630

59.5

68.9

3.1

12,250

11.1
12.1
13.5
14.8
17.2
19.6
23.9
26.8
31.3
35.7
41.6
45.5
50.7
56.0
63.9
70.7

16.0
17.2
18.6
20.1
22.7
25.3
29.8
33.1
38.5
43.1
49.6
53.7
59.3
65.0
73.7
80.9

0.9
1.0
1.0
1.1
1.2
1.3
1.5
1.6
1.8
2.0
2.3
2.4
2.7
2.9
3.2
3.5

410
490
600
730
1,000
1,330
1,940
2,490
3,370
4,470
6,000
7,250
8,840
10,810
13,980
17,150

Conductor
Resistance
(at 20C) (Max.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.076
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

Insulation Current Carrying


Capacity
Resistance
(at 20C)(Min,) (Max.) (at 45C)
M /km
A
1,300
15
1,100
21
920
29
790
36
640
50
530
67
510
89
440
105
440
135
370
170
360
205
320
240
330
270
330
305
310
365
310
415
530
67
510
89
530
440
105
510
440
135
510
380
170
440
370
205
440
330
240
380
330
270
370
330
305
370
320
365
330
1,300
15
1,100
21
920
29
790
36
640
50
530
67
510
89
440
105
440
135
370
170
360
205
320
240
330
270
330
305
310
365
310
415

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV RFOU, 0.6/1kV RFBU, 0.6/1kV RFCU

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

7 / 0.85

2.55

Tolerance

mm
16.4
17.6
19.9
21.7
22.8
23.8
25.0
28.6
29.1
30.0
32.2
36.9
17.4
18.5
21.0
23.2
24.1
25.4
26.5
30.6
31.2
32.1
34.9
39.5
18.5
19.9
22.6
24.2
25.0
26.1
27.3
28.7
30.0
33.2
34.2
35.3
38.6
42.9
20.3
21.7
25.0
27.7
28.9
30.5
31.9
37.9
38.8
40.0
43.0
48.5

mm
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.5
1.5
1.6
1.8
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.9
1.0
1.1
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.6
1.7
1.7
1.8
2.0
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.8
1.9
1.9
2.0
2.2

kg/km
420
480
610
730
810
880
980
1,260
1,320
1,410
1,630
2,140
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
570
670
860
970
1,060
1,170
1,280
1,440
1,550
1,880
2,020
2,170
2,650
3,220
710
850
1,110
1,380
1,520
1,700
1,900
2,620
2,790
3,000
3,520
4,360

Conductor
Resistance
(at 20C) (Max.)
/km

18.2

480
550
710
860
940
1,050
1,150
1,510
1,590
1,690
2,010
2,560

7.56

4.70

Insulation Current Carrying


Capacity
Resistance
(at 20C) (Min,) (Max.) (at 45C)
M /km
A
10
9
8
7
7
7
1,490
6
6
5
5
5
5
12
11
10
9
9
1,300
8
8
7
7
7
6
6
18
16
14
13
13
12
1,100
12
11
11
10
10
10
9
8
22
20
18
17
16
920
15
14
13
13
12
11
11

Offshore Cable

HV Power Cable

mm

Nominal

Cable
Weight

LV Power & Lighting Cable

No. / mm

Overall diameter

Instrumentation &
Communication Cable

Dia.

Nominal
dia.
inner
covering
mm
11.5
12.5
14.6
16.4
17.3
18.3
19.3
22.7
23.2
24.1
26.1
29.9
12.3
13.4
15.7
17.7
18.6
19.7
20.8
24.5
25.1
26.0
28.6
32.3
13.4
14.6
17.1
18.7
19.3
20.4
21.6
22.8
24.1
26.9
27.9
29.0
31.4
35.5
15.0
16.4
19.3
21.8
23.0
24.4
25.8
30.9
31.6
32.8
35.6
40.7

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

VFD Cable

No.
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
10
12
14
16
19
20
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44

Conductor
Nominal
Area
mm2

Technical Information

No. of
Cores

15

LV Power & Lighting Cable

CABLE DESIGNATION (P18)


0.6/1kV RU

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Classification
1. Conductor
2. Insulation

Construction detail

Code

Stranded tinned annealed copper wires as per IEC 60228, Class 2

EPR as per IEC 60092-351


- Insulated cores shall be cabled.

3. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

4. Sheath

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Black

0.6/1kV RU

No. of cores

5. Core identification

Without earth core

With earth core

1C

Black or Off-white

2C

Black, White

3C / 2C+E

Black, White, Red

Black, White, G/Y

4C / 3C+E

Black, White, Red, Blue

Black, White, Red, G/Y

5C / 4C+E

Black No. on white insulation Black, White, Red, Blue, G/Y

6C and over Black No. on white insulation Black No. on white insulation, G/Y

Note.
Flexible cable (Class5 Conductor) can be supplied

16

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV RU

2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth

mm
5.9
6.3
6.9
7.4
8.4
9.6
11.6
12.8
14.7
16.5
19.0
20.8
23.0
25.4
28.7
31.7
10.1
10.9
12.3
13.3
15.5
17.7
21.5
24.1
27.9
31.7
36.7
40.1
44.5
49.3
55.9
61.9
10.7
11.7
13.0
14.3
16.5
18.8
22.6

mm
0.5
0.6
0.6
0.6
0.6
0.7
0.8
0.8
0.9
1.0
1.1
1.1
1.2
1.3
1.4
1.6
0.7
0.7
0.8
0.8
0.9
1.0
1.2
1.3
1.4
1.6
1.8
1.9
2.1
2.3
2.5
2.8
0.7
0.8
0.8
0.9
1.0
1.1
1.2

kg/km
60
70
90
110
160
230
360
470
610
840
1,140
1,400
1,720
2,130
2,760
3,420
160
190
250
310
450
630
960
1,250
1,670
2,260
3,070
3,750
4,600
5,700
7,390
9,150
180
230
300
390
570
800
1,140

25.3

1.3

1,510

29.1

1.5

1,940

33.3

1.6

2,650

38.5

1.8

3,580

42.1

2.0

4,450

46.7

2.2

5,540

51.5

2.4

6,660

58.6

2.6

8,630

Current Carrying
Capacity
(Max.) (at 45C)
A
21
30
40
51
71
95
125
155
190
240
290
340
385
440
520
590
18
25
34
43
60
81
105
135
165
200
249
288
331
377
444
511
18
25
34
43
60
81
105

HV Power Cable

mm
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21

Tolerance

Conductor
Insulation
Resistance
Resistance
(at 20C) (Max.) (at 20C) (Min,)
/km
M /km
12.2
1,300
7.56
1,100
4.70
920
3.110
790
1.840
640
1.160
530
0.734
510
0.529
440
0.391
440
0.270
370
0.195
360
0.154
320
0.126
330
0.100
330
0.0762
310
0.0607
310
12.2
1,300
7.56
1,100
4.70
920
3.110
790
1.840
640
1.160
530
0.734
510
0.529
440
0.391
440
0.270
370
0.195
360
0.154
320
0.126
330
0.100
330
0.0762
310
0.0607
310
12.2
1,300
7.56
1,110
4.70
930
3.110
790
1.840
640
1.160
530
0.734
510
1.160
530
0.529
440
0.734
510
0.391
440
0.734
510
0.270
380
0.529
440
0.195
370
0.391
440
0.154
330
0.270
380
0.126
330
0.195
370
0.100
330
0.195
370
0.076
320
0.154
330

LV Power & Lighting Cable

No. / mm
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61/ 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03

Nominal

Cable
Weight

Instrumentation &
Communication Cable

Dia.

Overall diameter

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

VFD Cable

No.

Conductor
Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

135
165
200
249

Technical Information

No. of
Cores

288
331
377
444

Offshore Cable

17

LV Power & Lighting Cable


CABLE TYPE : 0.6/1kV RU
No. of
Cores
No.

3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

18

Conductor
Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

Offshore Cable

Strand

Dia.

No. / mm
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52

mm
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4

Overall diameter
Nominal

Tolerance

Cable
Weight

mm
10.7
11.7
13.0
14.3
16.5
18.8
23.1
25.9
29.7
34.0
39.4
43.0
47.7
52.9
60.2
66.6
11.8
12.8
14.4
15.7
18.3
20.9
24.4

mm
0.7
0.8
0.8
0.9
1.0
1.1
1.2
1.3
1.5
1.7
1.9
2.0
2.2
2.4
2.7
3.0
0.8
0.8
0.9
0.9
1.0
1.1
1.3

kg/km
180
230
300
390
570
800
1,230
1,620
2,140
2,940
4,010
4,910
6,020
7,480
9,740
12,070
220
280
380
490
720
1,020
1,430

28.0

1.4

1,950

31.4

1.6

2,460

35.9

1.7

3,360

41.5

2.0

4,560

45.6

2.1

5,690

51.0

2.3

7,110

55.5

2.5

8,520

62.8

2.8

11,000

11.8
12.8
14.4
15.7
18.3
20.9
25.6
28.7
33.2
37.8
43.9
48.0
53.2
58.9
67.0
74.4

0.8
0.8
0.9
0.9
1.0
1.1
1.3
1.4
1.6
1.8
2.1
2.2
2.4
2.7
3.0
3.3

220
280
380
490
720
1,020
1,570
2,070
2,760
3,780
5,160
6,330
7,770
9,640
12,550
15,610

Conductor
Insulation
Resistance
Resistance
(at 20C) (Max.) (at 20C) (Min,)
/km
M /km
12.2
1,300
7.56
1,100
4.70
920
3.110
790
1.840
640
1.160
530
0.734
510
0.529
440
0.391
440
0.270
370
0.195
360
0.154
320
0.126
330
0.100
330
0.0762
310
0.0607
310
12.2
1,300
7.56
1,110
4.70
930
3.110
790
1.840
640
1.160
530
0.734
510
1.160
530
0.529
440
0.734
510
0.391
440
0.734
510
0.270
380
0.529
440
0.195
370
0.391
440
0.154
330
0.270
380
0.126
330
0.195
370
0.100
330
0.195
370
0.076
320
0.154
330
12.2
1,300
7.56
1,100
4.70
920
3.110
790
1.840
640
1.160
530
0.734
510
0.529
440
0.391
440
0.270
370
0.195
360
0.154
320
0.126
330
0.100
330
0.0762
310
0.0607
310

Current Carrying
Capacity
(Max.) (at 45C)
A
15
21
29
36
50
67
89
105
135
170
205
240
270
305
365
415
15
21
29
36
50
67
89
105
135
170
205
240
270
305
365
15
21
29
36
50
67
89
105
135
170
205
240
270
305
365
415

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV RU

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

mm
11.9
12.9
15.2
17.2
18.1
19.1
20.3
23.9
24.4
25.5
27.7
31.3
12.7
13.8
16.3
18.5
19.6
20.7
21.8
25.9
26.5
27.6
29.8
33.9
13.8
15.2
17.9
20.3
21.4
22.8
24.0
28.5
29.1
30.4
33.0
37.3

mm
0.8
0.8
0.9
1.0
1.0
1.1
1.1
1.3
1.3
1.3
1.4
1.6
0.8
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.7
0.9
0.9
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.5
1.6
1.8

kg/km
220
260
350
450
510
570
640
880
930
1,010
1,200
1,520
260
320
430
560
630
710
790
1,090
1,160
1,270
1,490
1,890
330
410
560
730
820
930
1,050
1,430
1,520
1,670
1,990
2,490

18.2

1,490

12.2

1,300

7.56

1,100

Current Carrying
Capacity
(Max.) (at 45C)
A
10
9
8
7
7
7
6
6
6
5
5
5
12
11
10
9
9
8
8
7
7
7
6
6
18
16
14
13
12
12
11
10
10
10
9
8

HV Power Cable

mm

Tolerance

Conductor
Insulation
Resistance
Resistance
(at 20C) (Max.) (at 20C) (Min,)
/km
M /km

LV Power & Lighting Cable

No. / mm

Nominal

Cable
Weight

Instrumentation &
Communication Cable

Dia.

Overall diameter

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

VFD Cable

No.
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44

Conductor
Nominal
Area
mm2

Technical Information

No. of
Cores

Offshore Cable

19

LV Power & Lighting Cable

CABLE DESIGNATION (P5, P5/P12)


0.6/1kV BFOU, BFBU, BFCU

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Fire resistance

: IEC 60331-21, 31

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Fire resisting layer
Mica/glass tape
B
3. Insulation
EPR as per IEC 60092-351
- Insulated cores shall be cabled.

4. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

5. Inner covering
6. Armor

0.6/1kV BFOU

7. Sheath

F Flame retardant halogen free thermoset compound


O - Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) - A suitable separator tape(s) may be applied under/over the armor
U

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Black
No. of cores

8. Core identification

Without earth core

With earth core

1C

Black or Off-white

2C

Black, White

3C / 2C+E

Black, White, Red

Black, White, G/Y

4C / 3C+E

Black, White, Red, Blue

Black, White, Red, G/Y

5C / 4C+E

Black No. on white insulation Black, White, Red, Blue, G/Y

6C and over Black No. on white insulation Black No. on white insulation, G/Y

Note.
Flexible cable (Class5 Conductor) can be supplied

20

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV BFOU, 0.6/1kV BFBU

2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth

Nominal

Tolerance

mm
11.0
11.6
12.2
12.7
13.7
14.9
16.8
18.0
19.9
21.7
24.2
26.0
28.2
30.6
34.3
37.8
15.7
16.5
17.9
18.9
21.1
23.3
26.9
29.5
33.3
38.0
43.0
47.0
51.2
56.0
63.2
69.2
16.4
17.4
18.7
20.0
22.4
24.5
28.1

mm
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
1.7
1.8
0.9
1.0
1.0
1.1
1.1
1.2
1.4
1.5
1.6
1.8
2.0
2.2
2.3
2.5
2.8
3.1
1.0
1.0
1.0
1.1
1.2
1.3
1.4

24.7

30.8

1.5

1,970

28.6

34.9

1.7

2,490

32.4

39.6

1.9

3,360

37.3

44.9

2.1

4,400

41.0

48.8

2.3

5,380

45.2

53.4

2.4

6,560

50.2

58.8

2.7

7,870

56.7

65.9

2.9

9,990

kg/km
190
210
250
280
340
430
580
710
890
1,140
1,480
1,770
2,120
2,570
3,280
4,090
370
420
500
580
760
970
1,340
1,670
2,150
2,930
3,830
4,640
5,560
6,750
8,660
10,550
410
470
570
680
900
1,160
1,550

Conductor
Resistance
(at 20C) (Max.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.076
0.154

Insulation Current Carrying


Capacity
Resistance
(at 20C) (Min,) (Max.) (at 45C)
M /km
A
1,300
21
1,100
30
920
40
790
51
640
71
530
95
510
125
440
155
440
190
370
240
360
290
320
340
330
385
330
440
310
520
310
590
1,300
18
1,100
25
920
34
790
43
640
60
530
81
510
105
440
135
440
165
370
200
360
249
320
288
330
331
330
377
310
444
310
511
1,300
15
1,110
21
930
29
790
36
640
50
530
67
510
89
530
440
105
510
440
135
510
380
170
440
370
205
440
330
240
380
330
270
370
330
305
370
320
365
330

Offshore Cable

HV Power Cable

mm
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21

Cable
Weight

LV Power & Lighting Cable

No. / mm
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7/ 1.35
7/ 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03

Overall diameter

Instrumentation &
Communication Cable

Dia.

Nominal
dia.
inner
covering
mm
6.5
6.9
7.5
8.0
9.0
10.0
11.7
12.9
14.6
16.4
18.7
20.3
22.3
24.5
28.0
30.8
10.8
11.6
12.8
13.8
15.8
17.8
21.2
23.6
27.0
31.0
35.6
39.2
43.2
47.6
54.2
59.8
11.5
12.3
13.6
14.7
16.9
19.0
22.2

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

VFD Cable

No.

Conductor
Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

Technical Information

No. of
Cores

21

LV Power & Lighting Cable


CABLE TYPE : 0.6/1kV BFOU, 0.6/1kV BFBU, 0.6/1kV BFCU
No. of
Cores
No.

3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

22

Conductor
Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

Offshore Cable

Strand

Dia.

No. / mm
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 1.70
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52

mm
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
5.10
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4

Nominal
dia.
inner
covering
mm
11.5
12.3
13.6
14.7
16.9
19.0
22.7
25.3
29.3
33.2
38.6
42.0
46.3
51.5
58.1
64.6
21.0
24.2

Overall diameter
Nominal

Tolerance

Cable
Weight

mm
16.4
17.4
18.7
20.0
22.4
24.5
28.6
31.4
35.8
40.4
46.2
50.0
54.7
60.3
67.3
74.4
26.7
30.3

mm
1.0
1.0
1.0
1.1
1.2
1.3
1.4
1.6
1.7
1.9
2.1
2.3
2.5
2.7
3.0
3.3
1.4
1.5

kg/km
410
470
570
680
900
1,160
1,640
2,080
2,710
3,660
4,870
5,870
7,080
8,700
11,060
13,650
1,440
1,910

27.7

34.0

1.7

2,500

30.9

37.9

1.8

3,150

34.9

42.3

2.0

4,140

40.6

48.4

2.2

5,510

44.5

52.7

2.4

6,750

49.9

58.5

2.6

8,350

54.1

63.1

2.8

9,860

60.7

70.1

3.1

12,450

12.6
13.5
15.0
16.2
18.6
21.0
25.1
28.4
32.5
36.9
42.8
46.7
51.9
57.2
65.1
71.9

17.7
18.6
20.3
21.5
24.1
26.7
31.2
34.7
39.7
44.5
50.8
55.1
60.7
66.4
74.9
82.3

1.0
1.0
1.1
1.2
1.3
1.4
1.5
1.7
1.9
2.1
2.3
2.5
2.7
3.0
3.3
3.6

480
550
680
800
1,080
1,420
2,030
2,610
3,460
4,590
6,120
7,400
9,010
11,000
14,150
17,380

Conductor
Resistance
(at 20C) (Max.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.076
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

Insulation Current Carrying


Capacity
Resistance
(at 20C) (Min,) (Max.) (at 45C)
M /km
A
1,300
15
1,100
21
920
29
790
36
640
50
530
67
510
89
440
105
440
135
370
170
360
205
320
240
330
270
330
305
310
365
310
415
530
67
510
89
530
440
105
510
440
135
510
380
170
440
370
205
440
330
240
380
330
270
370
330
305
370
320
365
330
1,300
15
1,100
21
920
29
790
36
640
50
530
67
510
89
440
105
440
135
370
170
360
205
320
240
330
270
330
305
310
365
310
415

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV BFOU, 0.6/1kV BFBU, 0.6/1kV BFCU

14

Tolerance

mm
18.2

mm
1.0

kg/km
500

14.3

19.6

1.1

580

16.8

22.3

1.2

740

1.0

18.9

24.4

1.3

880

1.0

20.0

25.7

1.3

980

1.0

21.1

26.8

1.4

1,070

19

1.0

22.3

28.2

1.4

1,180

24

1.0

26.3

32.4

1.6

1,540

27

1.0

26.9

33.2

1.6

1,630

30

1.0

28.4

34.7

1.7

1,780

37

1.0

30.7

37.7

1.8

2,140

44

1.0

34.7

42.1

2.0

2,630

1.0

13.9

19.0

1.1

550

12

1.0

15.2

20.5

1.1

650

11

No.
5

16

1.0

Dia.

No. / mm

mm

7 / 0.43

1.29

7
18.2

1,490

1.0

17.8

23.3

1.2

830

10

12

1.0

20.2

25.9

1.3

1,030

14

1.0

21.3

27.0

1.4

1,120

1.0

22.5

28.4

1.4

1,240

19

1.0

23.8

29.7

1.5

1,370

24

1.0

28.5

34.8

1.7

1,840

27

1.0

29.2

35.7

1.7

1,950

30

1.0

30.3

37.3

1.8

2,170

37

1.0

32.8

40.0

1.9

2,510

44

1.0

37.1

44.7

2.1

3,090

1.0

15.0

20.3

1.1

650

18

1.0

16.4

21.7

1.2

760

16

1.0

19.3

25.0

1.3

1,000

14

12

1.0

21.8

27.7

1.4

1,230

13

14

1.0

23.0

28.9

1.5

1,350

1.0

24.4

30.5

1.5

1,510

19

1.0

25.8

31.9

1.6

1,670

11

24

1.0

30.9

37.9

1.8

2,330

10

27

1.0

31.6

38.8

1.9

2,470

10

30

1.0

32.8

40.0

1.9

2,640

10

37

1.0

35.6

43.0

2.0

3,070

44

1.0

40.7

48.5

2.2

3,830

1.0

16.6

21.9

1.2

800

22

1.0

18.2

23.7

1.2

960

20

1.0

21.4

27.1

1.4

1,240

18

12

1.0

24.3

30.4

1.5

1,560

17

14

1.0

25.7

31.8

1.6

1,730

1.0

27.2

33.5

1.6

1,930

19

1.0

29.2

35.7

1.7

2,200

14

24

1.0

34.5

41.9

2.0

3,000

13

27

1.0

35.3

42.7

2.0

3,170

13

30

1.0

36.7

44.3

2.1

3,430

12

37

1.0

40.2

48.0

2.2

4,060

11

44

1.0

45.5

53.7

2.4

4,990

11

16

16

16

1.5

2.5

7 / 0.53

7 / 0.67

7 / 0.85

1.59

2.01

2.55

HV Power Cable

12

Nominal

Strand

LV Power & Lighting Cable

1.0

Insulation Current Carrying


Capacity
Resistance
(at 20C) (Min,) (Max.) (at 45C)
M /km
A
10

Instrumentation &
Communication Cable

1.0

Conductor
Resistance
(at 20C) (Max.)
/km

Cable
Weight

9
12.2

1,300

Earthing & Bonding wire

Overall diameter

12
7.56

1,100

12

VFD Cable

Nominal
dia.
inner
covering
mm
13.1

Conductor
Nominal
Area
mm2

Technical Information

Thickness
of
Insulation
mm
1.0

No. of
Cores

16
4.70

920

15

Offshore Cable

23

LV Power & Lighting Cable

CABLE DESIGNATION (P17)


0.6/1kV BU

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Fire resistance

: IEC 60331-21, 31

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Fire resisting layer
Mica/glass tape
B
3. Insulation
EPR as per IEC 60092-351
- Insulated cores shall be cabled.

4. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

0.6/1KV BU

5. Sheath

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Black
No. of cores

6. Core identification

Without earth core

With earth core

1C

Black or Off-white

2C

Black, White

3C / 2C + E

Black, White, Red

Black, White, G/Y

4C / 3C + E

Black, White, Red, Blue

Black, White, Red, G/Y

5C / 4C+E

Black No. on white insulation Black, White, Red, Blue, G/Y

6C and over Black No. on white insulation Black No. on white insulation, G/Y
Note.
Flexible cable (Class5 Conductor) can be supplied

24

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV BU

2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth

mm
6.5
6.9
7.5
8.0
9.2
10.2
12.1
13.3
15.2
17.2
19.7
21.3
23.5
25.9
29.2
32.2
11.5
12.3
13.5
14.7
16.9
18.9
22.7
25.3
28.9
32.7
37.7
41.3
45.5
50.3
56.9
63.1
12.2
13.0
14.5
15.6
18.0
20.3
23.7

mm
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.9
1.0
1.1
1.2
1.2
1.3
1.5
1.6
0.8
0.8
0.8
0.9
1.0
1.1
1.2
1.3
1.5
1.6
1.8
2.0
2.1
2.3
2.6
2.8
0.8
0.8
0.9
0.9
1.0
1.1
1.2

kg/km
70
80
100
120
180
250
370
480
630
860
1,160
1,420
1,730
2,150
2,780
3,440
190
230
290
360
510
680
1,020
1,320
1,730
2,330
3,140
3,850
4,690
5,800
7,500
9,310
220
270
350
440
630
870
1,190

26.4

1.4

1,570

30.3

1.5

2,020

34.3

1.7

2,720

39.6

1.9

3,670

43.1

2.0

4,530

47.7

2.2

5,630

52.7

2.4

6,790

59.6

2.7

8,750

Current Carrying
Capacity
(Max.) (at 45C)
A
21
30
40
51
71
95
125
155
190
240
290
340
385
440
520
590
18
25
34
43
60
81
105
135
165
200
249
288
331
377
444
511
18
25
34
43
60
81
105

HV Power Cable

mm
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21

Tolerance

Conductor
Insulation
Resistance
Resistance
(at 20C) (Max.) (at 20C) (Min,)
/km
M /km
12.2
1,300
7.56
1,100
4.70
920
3.110
790
1.840
640
1.160
530
0.734
510
0.529
440
0.391
440
0.270
370
0.195
360
0.154
320
0.126
330
0.100
330
0.0762
310
0.0607
310
12.2
1,300
7.56
1,100
4.70
920
3.110
790
1.840
640
1.160
530
0.734
510
0.529
440
0.391
440
0.270
370
0.195
360
0.154
320
0.126
330
0.100
330
0.0762
310
0.0607
310
12.2
1,300
7.56
1,110
4.70
930
3.110
790
1.840
640
1.160
530
0.734
510
1.160
530
0.529
440
0.734
510
0.391
440
0.734
510
0.270
380
0.529
440
0.195
370
0.391
440
0.154
330
0.270
380
0.126
330
0.195
370
0.100
330
0.195
370
0.076
320
0.154
330

LV Power & Lighting Cable

No. / mm
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03

Nominal

Cable
Weight

Instrumentation &
Communication Cable

Dia.

Overall diameter

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6

VFD Cable

No.

Conductor
Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120

135
165
200
249

Technical Information

No. of
Cores

288
331
377
444

Offshore Cable

25

LV Power & Lighting Cable


CABLE TYPE : 0.6/1kV BU
No. of
Cores
No.

3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth

26

Conductor
Nominal
Area
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

Offshore Cable

Strand

Dia.

No. / mm
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 1.70
7 / 2.52
7 / 2.14
19 / 1.78
7 / 2.14
19 / 2.14
7 / 2.52
19 / 2.52
19 / 1.78
37 / 2.03
19 / 2.14
37 / 2.25
19 / 2.52
37 / 2.52
19 / 2.52
61 / 2.25
37 / 2.03
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52

mm
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68
1.59
2.01
2.55
3.12
4.05
5.10
6.42
5.10
7.56
6.42
8.90
6.42
10.70
7.56
12.60
8.90
14.21
10.70
15.75
12.60
17.64
12.60
20.25
14.21
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4

Overall diameter
Nominal

Tolerance

Cable
Weight

mm
12.2
13.0
14.5
15.6
18.0
20.3
24.2
27.0
31.0
35.1
40.5
44.3
48.8
54.0
61.2
67.7
13.3
14.4
15.9
17.3
19.9
22.5
25.9

mm
0.8
0.8
0.9
0.9
1.0
1.1
1.3
1.4
1.5
1.7
1.9
2.1
2.3
2.5
2.7
3.0
0.8
0.9
0.9
1.0
1.1
1.2
1.3

kg/km
220
270
350
440
630
870
1,280
1,680
2,220
3,010
4,090
5,020
6,120
7,590
9,840
12,200
270
330
430
550
790
1,100
1,520

29.2

1.5

2,030

32.6

1.6

2,550

37.0

1.8

3,460

42.7

2.0

4,680

47.0

2.2

5,840

52.4

2.4

7,270

56.8

2.6

8,670

64.0

2.9

11,180

13.3
14.4
15.9
17.3
19.9
22.5
26.8
29.9
34.4
39.2
45.1
49.4
54.6
60.3
68.4
75.6

0.8
0.9
0.9
1.0
1.1
1.2
1.4
1.5
1.7
1.9
2.1
2.3
2.5
2.7
3.0
3.3

270
330
430
550
790
1,100
1,630
2,140
2,830
3,880
5,260
6,460
7,910
9,800
12,720
15,770

Conductor
Insulation
Resistance
Resistance
(at 20C) (Max.) (at 20C) (Min,)
/km
M /km
12.2
1,300
7.56
1,100
4.70
920
3.110
790
1.840
640
1.160
530
0.734
510
0.529
440
0.391
440
0.270
370
0.195
360
0.154
320
0.126
330
0.100
330
0.0762
310
0.0607
310
12.2
1,300
7.56
1,110
4.70
930
3.110
790
1.840
640
1.160
530
0.734
510
1.160
530
0.529
440
0.734
510
0.391
440
0.734
510
0.270
380
0.529
440
0.195
370
0.391
440
0.154
330
0.270
380
0.126
330
0.195
370
0.100
330
0.195
370
0.076
320
0.154
330
12.2
1,300
7.56
1,100
4.70
920
3.110
790
1.840
640
1.160
530
0.734
510
0.529
440
0.391
440
0.270
370
0.195
360
0.154
320
0.126
330
0.100
330
0.0762
310
0.0607
310

Current Carrying
Capacity
(Max.) (at 45C)
A
15
21
29
36
50
67
89
105
135
170
205
240
270
305
365
415
15
21
29
36
50
67
89
105
135
170
205
240
270
305
365
15
21
29
36
50
67
89
105
135
170
205
240
270
305
365
415

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV BU

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

mm
13.5
14.9
17.6
19.9
21.0
22.3
23.5
27.9
28.5
29.6
32.1
36.5
14.5
15.8
18.6
21.2
22.5
23.7
25.2
29.7
30.6
31.7
34.4
39.1
15.6
17.2
20.3
23.0
24.2
25.8
27.2
32.3
33.2
34.4
37.4
42.5

mm
0.8
0.9
1.0
1.1
1.1
1.2
1.2
1.4
1.4
1.5
1.6
1.8
0.9
0.9
1.0
1.1
1.2
1.2
1.3
1.5
1.5
1.6
1.7
1.9
0.9
1.0
1.1
1.2
1.3
1.3
1.4
1.6
1.6
1.7
1.8
2.0

kg/km
260
320
440
570
640
720
800
1,110
1,170
1,270
1,500
1,920
320
380
520
680
770
860
980
1,330
1,430
1,540
1,830
2,320
390
490
660
860
960
1,090
1,230
1,690
1,810
1,960
2,340
2,960

18.2

1,490

12.2

1,300

7.56

1,100

Current Carrying
Capacity
(Max.) (at 45C)
A
10
9
8
7
7
7
6
6
6
5
5
5
12
11
10
9
9
8
8
7
7
7
6
6
18
16
14
13
12
12
11
10
10
10
9
8

HV Power Cable

mm

Tolerance

Conductor
Insulation
Resistance
Resistance
(at 20C) (Max.) (at 20C) (Min,)
/km
M /km

LV Power & Lighting Cable

No. / mm

Nominal

Cable
Weight

Instrumentation &
Communication Cable

Dia.

Overall diameter

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

VFD Cable

No.
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44

Conductor
Nominal
Area
mm2

Technical Information

No. of
Cores

Offshore Cable

27

Instrumentation & Communication Cable

Instrumentation &
Communication Cable

250V RFOU(c), RFBU(c), RFCU(c)

28 ~ 31

250C RFOU(i), RFBU(i), RFCU(i)

32 ~ 34

250V RFOU(i&c0, RFBU(i&c), RFCU(i&c)

35 ~ 37

250V BFOU(c), BFBU(c), BFCU(c)

38 ~ 40

250C BFOU(i), BFBU(i), BFCU(i)

41 ~ 43

250V BFOU(i&c), BFBU(i&c), BFCU(i&c)

44 ~ 45

HV Power Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE DESIGNATION (S2, S2/S6)

LV Power & Lighting Cable

250V RFOU(c), RFBU(c), RFCU(c)

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A
: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

- Halogen content

Classification
1. Conductor
2. Insulation
3. Twisting

Earthing & Bonding wire

CONSTRUCTION
Construction detail

Code

Stranded tinned annealed copper wires as per IEC 60228, Class 2

EPR as per IEC 60092-351


Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled.

4. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

8. Sheath

AL/PS tape + Tinned copper drain wire


Flame retardant halogen free thermoset compound
VFD Cable

7. Armor

(c)
F
O
(B,C)

- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

9. Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

Technical Information

250V RFOU(c)

5. Collective screen
6. Inner covering

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note.
Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

29

Instrumentation & Communication Cable


CABLE TYPE : 250V RFOU(c), 250V RFBU(c), 250V RFCU(c)
No. of
Pairs
No.
1P
2P
3P
4P
7P
8P
10 P
12 P
14 P
16 P
19P
2 4P
32 P
1P
2P
3P
4P
7P
8P
10 P
12 P
14 P
16 P
19 P
24 P
32P
1P
2P
3P
4P
7P
8P
10 P
12 P
14 P
16 P
19 P
24 P
32 P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P

30

Conductor
Nominal
Area
SGMM

Strand
No. / mm

Dia.
(ca.)
mm

0.75

7/ 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Offshore Cable

Thickness
of
Insulation
mm

Nominal
dia.
inner
covering
mm

Nominal

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

7.1
10.5
11.2
11.9
14.3
15.3
17.2
17.9
18.6
20.1
21.0
23.9
27.7
7.5
11.1
11.9
12.7
15.3
16.3
18.4
19.2
20.0
21.5
22.6
25.7
29.7
8.5
12.8
13.8
14.7
17.8
19.0
21.5
22.5
23.4
25.2
26.5
30.6
34.9
9.3
14.2
15.3
16.3
19.8
21.2
24.0
25.1
26.1
28.6
30.0
34.2
39.5

11.6
15.2
15.9
16.8
19.2
20.4
22.5
23.2
23.9
25.6
26.5
29.6
33.8
12.0
15.8
16.8
17.6
20.4
21.4
23.7
24.5
25.5
27.0
28.3
31.6
36.0
13.0
17.7
18.7
19.8
23.1
24.3
27.0
28.2
29.1
31.1
32.4
37.4
42.1
13.8
19.1
20.4
21.4
25.3
26.7
29.7
31.0
32.0
34.7
36.8
41.4
47.1

Overall diameter

mm

Tolerance
mm
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.3
1.4
1.5
1.7
0.8
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.4
1.6
1.7
0.8
1.0
1.0
1.1
1.2
1.3
1.4
1.4
1.5
1.5
1.6
1.8
2.0
0.9
1.1
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.7
1.8
2.0
2.2

Cable
Weight
Approx.
kg / km
230
350
390
440
580
640
750
820
890
990
1,090
1,310
1,680
250
370
430
490
660
710
840
930
1,020
1,120
1,260
1,520
1,950
290
450
530
600
830
910
1,080
1,210
1,330
1,480
1,660
2,160
2,710
330
530
640
730
1,040
1,140
1,360
1,540
1,700
1,950
2,290
2,800
3,600

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C)(Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

NEK-606 (2004), IEC 60092-350, 353, 354, 376

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Nominal

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

7.5
11.5
12.2
13.4
16.8
18.0
20.4
21.6
22.6
24.0
26.0
29.2
33.6
7.9
12.2
13.0
14.3
17.9
19.2
21.8
23.1
24.1
25.7
28.2
31.3
36.0
9.0
14.1
15.0
16.6
21.0
22.5
25.6
27.6
28.8
30.7
33.2
36.9
42.9
9.9
15.7
16.8
18.5
23.5
25.2
29.2
30.9
32.3
34.4
37.3
41.9
48.6

12.0
16.2
17.1
18.3
21.9
23.3
25.9
27.1
28.3
29.7
31.9
35.3
40.6
12.4
17.1
17.9
19.2
23.2
24.5
27.3
28.8
29.8
31.6
34.3
38.1
43.2
13.5
19.0
20.1
21.7
26.5
28.2
31.5
33.7
34.9
37.5
40.2
44.3
50.7
14.6
20.8
21.9
23.8
29.2
31.1
35.3
37.7
39.3
41.6
44.7
49.7
56.8

Overall diameter

mm

Tolerance
mm
0.8
0.9
1.0
1.0
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.9
0.8
1.0
1.0
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.7
1.8
2.0
0.8
1.1
1.1
1.2
1.4
1.4
1.6
1.6
1.7
1.8
1.9
2.1
2.3
0.9
1.1
1.2
1.3
1.5
1.5
1.7
1.8
1.9
2.0
2.1
2.3
2.6

Cable
Weight
Approx.
kg / km
250
400
460
530
740
820
970
1,080
1,200
1,310
1,500
1,830
2,400
270
440
510
590
840
930
1,100
1,240
1,370
1,520
1,780
2,220
2,790
320
530
630
740
1,090
1,210
1,450
1,690
1,860
2,170
2,470
2,980
3,830
380
650
770
930
1,380
1,540
1,900
2,260
2,520
2,810
3,220
3,970
5,110

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C)(Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

LV Power & Lighting Cable

0.75

Nominal
dia.
inner
covering
mm

Instrumentation &
Communication Cable

No. / mm

Thickness
of
Insulation
mm

Earthing & Bonding wire

Strand

Dia.
(ca.)
mm

VFD Cable

No.
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T

Conductor
Nominal
Area
SGMM

Offshore Cable

Technical Information

No. of
Triads

HV Power Cable

CABLE TYPE : 250V RFOU(c), 250V RFBU(c), 250V RFCU(c)

31

Instrumentation & Communication Cable

CABLE DESIGNATION (S1, S1/S5)


250V RFOU(i), RFBU(i), RFCU(i)

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Insulation
R EPR as per IEC 60092-351
3. Twisting
Two/Three Insulated cores shall be twisted together to form a pair/Triad
4. Individual screen (i) AL/PS tape + Tinned copper drain wire
- Twisted pairs / triads shall be cabled.

5. Cabling

- Flame retardant & non-hygroscopic fillers may be used .

250V RFOU(i)

- Suitable tape(s) may be applied on the cabled core.

6. Inner covering
7. Armor
8. Sheath

F Flame retardant halogen free thermoset compound


O - Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) - A suitable separator tape(s) may be applied under/over the armor
U

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

9. Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note.
Flexible cable (Class5 Conductor) can be supplied

32

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Nominal

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

7.1
10.8
11.5
12.3
14.9
15.9
17.9
18.7
19.4
21.0
22.0
25.1
29.0
7.5
11.5
12.3
13.1
15.9
17.0
19.2
20.0
20.8
22.5
23.6
26.9
31.1
8.5
13.2
14.1
15.1
18.4
19.7
22.3
23.2
24.2
26.2
27.9
31.8
36.3
9.3
14.5
15.6
16.7
20.4
21.8
24.7
25.8
27.3
29.5
31.0
35.4
40.9

11.6
15.5
16.2
17.2
20.0
21.0
23.2
24.0
24.9
26.5
27.7
31.0
35.1
12.0
16.2
17.2
18.0
21.0
22.3
24.5
25.5
26.3
28.2
29.3
33.0
37.9
13.0
18.1
19.0
20.2
23.7
25.2
28.0
28.9
29.9
32.1
34.0
38.8
43.5
13.8
19.6
20.7
21.8
25.9
27.3
30.6
31.7
33.4
35.8
37.8
42.6
48.5

Overall diameter

mm

Tolerance
mm
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.3
1.4
1.4
1.5
1.7
0.8
0.9
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.8
0.8
1.0
1.1
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.7
1.9
2.0
0.9
1.1
1.1
1.2
1.3
1.4
1.5
1.6
1.6
1.7
1.8
2.0
2.2

Cable
Weight
Approx.
kg / km
230
360
410
480
660
720
850
940
1,040
1,150
1,300
1,570
2,010
250
390
470
530
740
820
970
1,090
1,200
1,340
1,510
1,850
2,460
290
480
560
650
920
1,030
1,230
1,370
1,520
1,710
1,980
2,520
3,160
330
560
670
780
1,150
1,270
1,540
1,730
1,990
2,230
2,620
3,210
4,150

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C)(Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

LV Power & Lighting Cable

0.75

Nominal
dia.
inner
covering
mm

Instrumentation &
Communication Cable

No. / mm

Thickness
of
Insulation
mm

Earthing & Bonding wire

Strand

Dia.
(ca.)
mm

VFD Cable

No.
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P

Conductor
Nominal
Area
SGMM

Offshore Cable

Technical Information

No. of
Pairs

HV Power Cable

CABLE TYPE : 250V RFOU(i), 250V RFBU(i), 250V RFCU(i)

33

Instrumentation & Communication Cable


CABLE TYPE : 250V RFOU(i), 250V RFCU(i), 250V RFBU(i)
No. of
Triads
No.
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T

34

Conductor
Nominal
Area
SGMM

Strand
No. / mm

Dia.
(ca.)
mm

0.75

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Offshore Cable

Thickness
of
Insulation
mm

Nominal
dia.
inner
covering
mm

Nominal

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

7.5
11.8
12.6
13.8
15.4
17.4
17.4
18.7
21.2
22.5
23.5
25.1
27.5
30.6
35.2
7.9
12.5
13.3
14.7
18.5
19.9
22.6
24.0
25.1
26.7
29.4
32.6
37.9
9.0
14.4
15.4
17.0
21.6
23.2
26.5
28.5
29.8
31.7
34.4
38.6
44.5
9.9
16.0
17.1
19.0
24.1
25.9
30.0
31.8
33.3
35.5
38.9
43.2
50.2

12.0
16.5
17.5
18.7
20.5
22.7
22.7
24.0
26.7
28.2
29.2
31.0
33.6
37.4
42.4
12.4
17.4
18.2
19.8
23.8
25.4
28.3
29.7
31.0
32.6
35.7
39.6
45.3
13.5
19.5
20.5
22.3
27.1
28.9
32.4
34.6
36.1
38.7
41.6
46.0
52.5
14.6
21.1
22.4
24.3
29.8
31.8
36.8
38.8
40.3
42.7
46.5
51.0
58.6

Overall diameter

mm

Tolerance
mm
0.8
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.5
1.6
1.8
2.0
0.8
1.0
1.0
1.1
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.9
2.1
0.8
1.1
1.1
1.2
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.1
2.4
0.9
1.1
1.2
1.3
1.5
1.6
1.8
1.9
1.9
2.0
2.2
2.3
2.6

Cable
Weight
Approx.
kg / km
250
410
490
560
660
770
820
900
1,080
1,220
1,340
1,500
1,760
2,200
2,770
270
460
540
640
930
1,040
1,240
1,400
1,570
1,730
2,050
2,560
3,300
320
560
670
800
1,180
1,320
1,590
1,860
2,080
2,410
2,770
3,390
4,330
380
670
820
990
1,490
1,670
2,180
2,480
2,760
3,090
3,640
4,390
5,720

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C)(Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

HV Power Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE DESIGNATION

LV Power & Lighting Cable

250V RFOU(i&c), RFBU(i&c), RFCU(i&c)

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A
: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

- Halogen content

Earthing & Bonding wire

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Insulation
R EPR as per IEC 60092-351
3. Twisting
Two/Three Insulated cores shall be twisted together to form a pair/Triad
4. Individual screen (i) AL/PS tape + Tinned copper drain wire
- Twisted pairs / triads shall be cabled.

5. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

9. Sheath

AL/PS tape + Tinned copper drain wire


VFD Cable

8. Armor

(c)
F
O
(B,C)

Flame retardant halogen free thermoset compound


- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

10. Core identification

Pair : Black, Light blue

Technical Information

250V RFOU(i&c)

6. Collective screen
7. Inner covering

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note.
Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

35

Instrumentation & Communication Cable


CABLE TYPE : 250V RFOU(i&c), 250V RFBU(i&c), 250V RFCU(i&c)
No. of
Pairs
No.
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19 P
24P
32 P
2p
3p
4p
7p
8p
10p
12p
14p
16p
19p
24p
32p

36

Conductor
Nominal
Area
SGMM

Strand
No. / mm

Dia.
(ca.)
mm

0.75

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Offshore Cable

Thickness
of
Insulation
mm

Nominal
dia.
inner
covering
mm

Nominal

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

11.0
11.7
12.5
15.1
16.1
18.1
18.9
19.6
21.2
22.2
25.3
29.2
11.7
12.5
13.3
16.1
17.2
19.4
20.2
21.0
22.7
23.8
27.5
31.3
13.4
14.3
15.3
17.3
18.6
18.6
19.9
22.5
23.4
24.4
26.4
28.1
32.0
36.5
14.7
15.8
16.9
20.6
22.0
24.9
26.0
27.5
29.7
31.2
35.6
41.1

15.7
16.4
17.4
20.2
21.2
23.4
24.2
25.1
26.7
27.9
31.2
35.3
16.4
17.4
18.2
21.2
22.5
24.9
25.7
26.5
28.4
29.5
33.6
38.1
18.3
19.2
20.4
22.6
23.9
23.9
25.4
28.2
29.1
30.3
32.3
34.2
39.0
43.9
19.8
20.9
22.2
26.1
27.7
30.8
31.9
33.6
36.0
38.0
42.8
48.7

Overall diameter

mm

Tolerance
mm
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.3
1.4
1.4
1.5
1.7
1.0
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.8
1.0
1.1
1.1
1.2
1.3
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.9
2.1
1.1
1.1
1.2
1.3
1.4
1.5
1.6
1.6
1.7
1.8
2.0
2.2

Cable
Weight
Approx.
kg / km
380
430
490
680
740
870
960
1,060
1,180
1,330
1,600
2,040
410
490
550
770
850
1,010
1,120
1,230
1,370
1,540
1,920
2,500
500
580
670
800
890
950
1,060
1,260
1,400
1,560
1,740
2,010
2,560
3,230
590
700
820
1,180
1,310
1,570
1,770
2,020
2,270
2,660
3,260
4,200

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C)(Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

NEK-606 (2004), IEC 60092-350, 353, 354, 376

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Nominal

12.0
12.8
14.0
15.6
17.6
17.6
18.9
21.4
22.7
23.9
25.3
27.7
30.8
35.4
12.7
13.5
14.9
18.7
20.1
22.8
24.2
25.3
26.9
29.6
32.8
38.1
14.6
15.6
17.2
21.8
23.4
26.7
28.7
30.0
31.9
34.6
38.8
44.7
16.2
17.3
19.2
24.3
26.1
30.2
32.0
33.5
35.7
39.1
43.4
50.4

16.9
17.7
18.9
20.7
22.9
22.9
24.2
26.9
28.4
29.4
31.2
33.8
37.6
42.6
17.6
18.4
20.0
24.0
25.6
28.5
29.9
31.2
33.0
35.9
39.8
45.5
19.7
20.7
22.5
27.3
29.1
32.6
34.8
36.8
38.9
41.8
46.2
52.7
21.3
22.6
24.5
30.0
32.0
37.0
39.0
40.5
42.9
46.7
51.2
58.8

Overall diameter

mm

Tolerance
mm
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.5
1.7
1.8
2.0
1.0
1.0
1.1
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.9
2.1
1.1
1.1
1.2
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.4
1.2
1.2
1.3
1.5
1.6
1.8
1.9
1.9
2.0
2.2
2.3
2.7

Cable
Weight
Approx.
kg / km
440
510
580
680
800
840
930
1,100
1,250
1,370
1,530
1,790
2,230
2,810
480
560
670
960
1,070
1,270
1,430
1,600
1,780
2,090
2,600
3,350
580
690
830
1,210
1,350
1,620
1,890
2,210
2,450
2,810
3,430
4,380
690
850
1,020
1,530
1,710
2,220
2,530
2,810
3,130
3,690
4,450
5,770

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C)(Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

LV Power & Lighting Cable

0.75

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

Nominal
dia.
inner
covering
mm

Instrumentation &
Communication Cable

No. / mm

Thickness
of
Insulation
mm

Earthing & Bonding wire

Strand

Dia.
(ca.)
mm

VFD Cable

No.
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T

Conductor
Nominal
Area
SGMM

Offshore Cable

Technical Information

No. of
Triads

HV Power Cable

CABLE TYPE : 250V RFOU(i&c), 250V RFCU(i&c), 250V RFBU(i&c)

37

Instrumentation & Communication Cable

CABLE DESIGNATION (S4, S4/S8)


250V BFOU(c), BFBU(c), BFCU(c)

APPLICATION STANDARD
- Design guide: NEK-606 & IEC 60092-376
: IEC 60332-1 &

- Flame retardant

IEC 60332-3 Category A


- Fire resistance

: IEC 60331-21, 31

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Fire resisting layer
Mica/glass tape
B
3. Insulation
EPR as per IEC 60092-351
4. Twisting
Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled.

5. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

250V BFOU(c)

6. Collective screen
7. Inner covering
8. Armor
9. Sheath

(c)
F
O
(B,C)
U

AL/PS tape + Tinned copper drain wire


Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

10. Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note.
Flexible cable (Class5 Conductor) can be supplied

38

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Nominal

8.1
12.2
13.0
13.9
16.8
18.0
20.3
21.2
22.0
23.8
24.9
28.8
32.9
8.5
12.8
13.8
14.7
17.8
19.0
21.5
22.5
23.4
25.2
26.5
30.6
34.9
9.5
14.5
15.6
16.7
20.3
21.7
24.6
25.7
26.8
29.3
30.8
35.1
40.5
10.3
15.9
17.1
18.3
22.3
23.9
27.5
28.7
29.9
32.3
33.9
39.1
44.7

12.6
17.1
17.9
18.8
21.9
23.3
25.8
26.7
27.7
29.5
30.8
34.9
39.9
13.0
17.7
18.7
19.8
23.1
24.3
27.0
28.2
29.1
31.1
32.4
37.4
42.1
14.2
19.6
20.7
21.8
25.8
27.2
30.5
31.6
32.7
35.4
37.6
42.3
48.1
15.0
21.0
22.4
23.6
28.0
29.6
33.6
34.8
36.2
39.3
41.1
46.7
52.7

Overall diameter

mm

Tolerance
mm
0.8
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.5
1.7
1.9
0.8
1.0
1.0
1.1
1.2
1.3
1.4
1.4
1.5
1.5
1.6
1.8
2.0
0.9
1.1
1.1
1.2
1.3
1.4
1.5
1.6
1.6
1.7
1.8
2.0
2.2
0.9
1.1
1.2
1.2
1.4
1.5
1.6
1.7
1.7
1.9
1.9
2.2
2.4

Cable
Weight
Approx.
kg / km
260
400
450
500
670
750
880
960
1,050
1,160
1,290
1,590
2,070
280
440
500
560
760
830
980
1,090
1,180
1,310
1,450
1,900
2,360
320
520
600
680
940
1,030
1,240
1,370
1,500
1,720
2,020
2,450
3,130
370
600
710
810
1,160
1,280
1,580
1,760
1,950
2,280
2,570
3,180
4,000

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C) (Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

LV Power & Lighting Cable

0.75

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

Nominal
dia.
inner
covering
mm

Instrumentation &
Communication Cable

No. / mm

Thickness
of
Insulation
mm

Earthing & Bonding wire

Strand

Dia.
(ca.)
mm

VFD Cable

No.
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P

Conductor
Nominal
Area
SGMM

Offshore Cable

Technical Information

No. of
Pairs

HV Power Cable

CABLE TYPE : 250V BFOU(c), 250V BFBU(c), 250V BFCU(c)

39

Instrumentation & Communication Cable


CABLE TYPE : 250V BFOU(c), 250V BFBU(c), 250V BFCU(c)
No. of
Triads
No.
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T

40

Conductor
Nominal
Area
SGMM

Strand
No. / mm

Dia.
(ca.)
mm

0.75

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Offshore Cable

Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

Nominal
dia.
inner
covering
mm
8.6
13.4
14.3
15.7
19.8
21.3
24.2
25.7
26.9
29.0
31.4
34.9
40.5
9.0
14.1
15.0
16.6
21.0
22.5
25.6
27.6
28.8
30.7
33.2
36.9
42.9
10.1
16.1
17.1
18.9
24.0
25.8
29.8
31.7
33.1
35.3
38.6
42.9
49.8
10.9
17.5
18.7
20.7
26.2
28.6
32.6
34.6
36.2
39.0
42.2
47.0
54.6

Overall diameter
Nominal
mm
13.1
18.3
19.2
20.8
25.3
26.8
29.9
31.6
33.0
35.1
38.4
42.1
48.1
13.5
19.0
20.1
21.7
26.5
28.2
31.5
33.7
34.9
37.5
40.2
44.3
50.7
14.8
21.2
22.4
24.2
29.7
31.7
36.1
38.7
40.1
42.5
46.0
50.7
58.2
15.6
22.8
24.0
26.2
32.1
34.7
39.6
41.8
43.4
46.6
50.0
55.2
63.4

Tolerance
mm
0.8
1.0
1.1
1.1
1.3
1.4
1.5
1.6
1.6
1.7
1.8
2.0
2.2
0.8
1.1
1.1
1.2
1.4
1.4
1.6
1.6
1.7
1.8
1.9
2.1
2.3
0.9
1.1
1.2
1.3
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.3
2.6
0.9
1.2
1.3
1.3
1.6
1.7
1.9
2.0
2.0
2.2
2.3
2.5
2.8

Cable
Weight
Approx.
kg / km
290
460
530
620
880
960
1,140
1,280
1,420
1,590
1,920
2,270
2,890
310
500
590
680
980
1,090
1,290
1,500
1,640
1,910
2,170
2,590
3,310
360
610
720
840
1,230
1,370
1,700
2,020
2,220
2,460
2,860
3,440
4,430
420
720
860
1,030
1,530
1,750
2,220
2,520
2,780
3,180
3,640
4,400
5,690

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C) (Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

HV Power Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE DESIGNATION (S3, S3/S7)

LV Power & Lighting Cable

250V BFOU(i), BFBU(i), BFCU(i)

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &

- Fire resistance

: IEC 60331-21, 31

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

Instrumentation &
Communication Cable

IEC 60332-3 Category A

Earthing & Bonding wire

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Fire resisting layer
Mica/glass tape
B
3. Insulation
EPR as per IEC 60092-351
4. Twisting
Two/Three Insulated cores shall be twisted together to form a pair/Triad
5. Individual screen (i) AL/PS tape + Tinned copper drain wire
- Twisted pairs / triads shall be cabled.

6. Cabling

- Flame retardant & non-hygroscopic fillers may be used .

8. Armor
9. Sheath

VFD Cable

7. Inner covering

Flame retardant halogen free thermoset compound

O - Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) - A suitable separator tape(s) may be applied under/over the armor
U

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

10. Core identification

Pair : Black, Light blue

Technical Information

250V BFOU(i)

- Suitable tape(s) may be applied on the cabled core.

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note.
Flexible cable (Class5 Conductor) can be supplied

Offshore Cable

41

Instrumentation & Communication Cable


CABLE TYPE : 250V BFOU(i), 250V BFBU(i), 250V BFCU(i)
No. of
Pairs
No.
1P
2P
3P
4P
7P
8P
1P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
7P
8P
10P
12P
14P
16P
19P
24P
32P

42

Conductor
Nominal
Area
SGMM

Strand
No. / mm

Dia.
(ca.)
mm

0.75

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Offshore Cable

Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

Nominal
dia.
inner
covering
mm

Nominal

8.1
12.5
13.4
14.3
17.4
18.6
21.0
21.9
22.8
24.7
25.9
30.0
34.2
8.5
13.2
14.1
15.1
18.4
19.7
22.3
23.2
24.2
26.2
27.9
31.8
36.3
9.5
14.9
16.0
17.1
20.9
22.4
25.4
26.5
28.0
30.3
31.8
36.3
41.9
10.3
16.2
17.5
18.7
22.9
24.5
28.2
29.5
30.7
33.2
34.9
40.3
46.1

12.6
17.4
18.3
19.2
22.7
23.9
26.5
27.6
28.5
30.6
31.8
36.8
41.4
13.0
18.1
19.0
20.2
23.7
25.2
28.0
28.9
29.9
32.1
34.0
38.8
43.5
14.2
20.0
21.1
22.4
26.4
28.1
31.3
32.4
34.1
37.1
38.8
43.5
49.7
15.0
21.3
22.8
24.0
28.6
30.4
34.3
35.8
37.5
40.2
42.1
47.9
54.1

Overall diameter

mm

Tolerance
mm
0.8
1.0
1.0
1.1
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.8
2.0
0.8
1.0
1.1
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.7
1.9
2.0
0.9
1.1
1.1
1.2
1.4
1.4
1.6
1.6
1.7
1.8
1.9
2.0
2.3
0.9
1.2
1.2
1.3
1.4
1.5
1.7
1.7
1.8
1.9
2.0
2.2
2.5

Cable
Weight
Approx.
kg / km
260
420
480
540
760
830
990
1,100
1,200
1,350
1,500
1,970
2,460
280
460
530
610
850
950
1,120
1,250
1,370
1,540
1,770
2,260
2,820
320
540
630
740
1,040
1,160
1,380
1,540
1,760
2,060
2,330
2,820
3,640
370
620
750
870
1,280
1,420
1,750
1,980
2,290
2,560
2,910
3,620
4,590

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C) (Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

NEK-606 (2004), IEC 60092-350, 353, 354, 376

7 / 0.37

1.11

1.0

7 / 0.43

1.29

1.5

7 / 0.53

1.59

2.5

7 / 0.67

2.01

Nominal

8.6
13.7
14.7
16.2
20.5
22.0
25.1
26.6
28.2
30.1
32.5
36.2
42.1
9.0
14.4
15.4
17.0
21.6
23.2
26.5
28.5
29.8
31.7
34.4
38.6
44.5
10.1
16.4
17.5
19.4
24.7
26.5
30.7
32.6
34.1
36.3
39.8
44.2
51.4
10.9
17.8
19.0
21.1
26.9
29.3
33.5
35.5
37.2
40.1
43.4
48.7
56.2

13.1
18.6
19.8
21.3
26.0
27.7
31.0
32.5
34.3
36.9
39.5
43.4
49.9
13.5
19.5
20.5
22.3
27.1
28.9
32.4
34.6
36.1
38.7
41.6
46.0
52.5
14.8
21.5
22.8
24.9
30.6
32.4
37.5
39.6
41.3
43.5
47.4
52.2
60.0
15.6
23.1
24.3
26.6
33.0
35.4
40.5
42.7
44.6
47.7
51.2
56.9
65.0

Overall diameter

mm

Tolerance
mm
0.8
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2.0
2.3
0.8
1.1
1.1
1.2
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.1
2.4
0.9
1.2
1.2
1.3
1.5
1.6
1.8
1.9
2.0
2.0
2.2
2.4
2.7
0.9
1.2
1.3
1.4
1.6
1.7
1.9
2.0
2.1
2.2
2.3
2.6
2.9

Cable
Weight
Approx.
kg / km
290
480
570
660
960
1,060
1,270
1,420
1,620
1,890
2,150
2,560
3,310
310
530
620
740
1,070
1,190
1,430
1,670
1,850
2,160
2,460
3,000
3,810
360
630
760
910
1,350
1,490
1,950
2,210
2,460
2,710
3,180
3,840
4,970
420
750
900
1,090
1,670
1,890
2,400
2,740
3,060
3,480
3,990
4,920
6,300

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C) (Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

LV Power & Lighting Cable

0.75

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

Nominal
dia.
inner
covering
mm

Instrumentation &
Communication Cable

No. / mm

Thickness
of
Insulation
mm

Earthing & Bonding wire

Strand

Dia.
(ca.)
mm

VFD Cable

No.
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
7T
8T
10T
12T
14T
16T
19T
24T
32T

Conductor
Nominal
Area
SGMM

Offshore Cable

Technical Information

No. of
Triads

HV Power Cable

CABLE TYPE : 250V BFOU(i), 250V BFBU(i), 250V BFCU(i)

43

Instrumentation & Communication Cable

CABLE DESIGNATION
250V BFOU(i&c), BFBU(i&c), BFCU(i&c)

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-376

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Fire resistance

: IEC 60331-21, 31

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Fire resisting layer
Mica/glass tape
B
3. Insulation
EPR as per IEC 60092-351
4. Twisting
Two/Three Insulated cores shall be twisted together to form a pair/Triad
5. Individual screen (i) AL/PS tape + Tinned copper drain wire
- Twisted pairs / triads shall be cabled.

6. Cabling

- Flame retardant & non-hygroscopic fillers may be used .

250V BFOU(i&c)

- Suitable tape(s) may be applied on the cabled core.

7. Collective screen
8. Inner covering
9. Armor
10. Sheath

(c)
F
O
(B,C)
U

AL/PS tape + Tinned copper drain wire


Flame retardant halogen free thermoset compound
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
- A suitable separator tape(s) may be applied under/over the armor
- SHF2 or SHF Mud as per IEC 60092-359
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type)
- Each Pair / Triad : Core color

11. Core identification

Pair : Black, Light blue

Triad : Black, Light blue, Brown

- Multi Pairs / Triads : Number printing on the insulation or numbered tape


Note.
Flexible cable (Class5 Conductor) can be supplied

44

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

Nominal

Overall diameter

mm

Tolerance
mm

Cable
Weight
Approx.
kg / km

2P

0.6

12.7

17.6

1.0

440

3P

0.6

13.6

18.5

1.0

500

4P

0.6

14.5

19.6

1.1

570

7P

0.6

17.6

22.9

1.2

780

8P

0.6

18.8

24.1

1.3

860

0.6

21.2

26.7

1.4

1,010

12P

0.6

22.1

27.8

1.4

1,130

14P

0.6

23.0

28.7

1.4

1,230

16P

0.6

24.9

30.8

1.5

1,380

19P

0.6

26.1

32.0

1.6

1,530

24P

0.6

30.2

37.0

1.8

2,000

32P

0.6

34.4

41.6

2.0

2,490

2P

0.6

13.4

18.3

1.0

480

3P

0.6

14.3

19.2

1.1

550

4P

0.6

15.3

20.4

1.1

630

7P

0.6

18.6

23.9

1.3

880

8P

0.6

19.9

25.4

1.3

970

0.6

22.5

28.2

1.4

1,150

12P

0.6

23.4

29.1

1.5

1,280

14P

0.6

24.4

30.3

1.5

1,420

16P

0.6

26.4

32.3

1.6

1,570

19P

0.6

28.1

34.2

1.7

1,810

24P

0.6

32.0

39.0

1.9

2,300

32P

0.6

36.5

43.9

2.1

2,880

2P

0.7

15.1

20.2

1.1

560

3P

0.7

16.2

21.3

1.2

660

4P

0.7

17.3

22.6

1.2

760

7P

0.7

21.1

26.6

1.4

1,070

10P

10P

0.75

1.0

7 / 0.37

7 / 0.43

1.11

1.29

8P

0.7

22.6

28.3

1.4

1,190

0.7

25.6

31.5

1.6

1,420

12P

0.7

26.7

32.6

1.6

1,580

14P

0.7

28.2

34.3

1.7

1,800

16P

0.7

30.5

37.3

1.8

2,100

19P

0.7

32.0

39.0

1.9

2,360

24P

0.7

36.5

43.9

2.1

2,880

32P

0.7

42.1

49.9

2.3

3,690

2P

0.7

16.4

21.5

1.2

650

3P

0.7

17.7

23.0

1.2

780

4P

0.7

18.9

24.2

1.3

900

7P

0.7

23.1

28.8

1.5

1,310

0.7

24.7

30.6

1.5

1,460

0.7

28.4

34.5

1.7

1,790

12P

0.7

29.7

36.0

1.7

2,020

14P

0.7

30.9

37.7

1.8

2,330

16P

0.7

33.4

40.4

1.9

2,610

19P

0.7

35.1

42.3

2.0

2,950

24P

0.7

40.5

48.1

2.2

3,670

32P

0.7

46.3

54.3

2.5

4,640

10P

1.5

7 / 0.53

1.59

8P
10P

2.5

7 / 0.67

2.01

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C) (Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

LV Power & Lighting Cable

Nominal
dia.
inner
covering
mm

Instrumentation &
Communication Cable

No. / mm

Thickness
of
Insulation
mm

Earthing & Bonding wire

Strand

Dia.
(ca.)
mm

VFD Cable

No.

Conductor
Nominal
Area
SGMM

Offshore Cable

Technical Information

No. of
Pairs

HV Power Cable

CABLE TYPE : 250V BFOU(i&c), 250V BFBU(i&c), 250V BFCU(i&c)

45

Instrumentation & Communication Cable


CABLE TYPE : 250V BFOU(i&c), 250V BFBU(i&c), 250V BFCU(i&c)
No. of
Triads
No.

Conductor
Nominal
Area
SGMM

Strand
No. / mm

Dia.
(ca.)
mm

Thickness
of
Insulation
mm

Nominal
dia.
inner
covering
mm

Nominal

Overall diameter

mm

Tolerance
mm

Cable
Weight
Approx.
kg / km

2T

0.6

13.9

18.8

1.1

500

3T

0.6

14.9

20.0

1.1

590

4T

0.6

16.4

21.5

1.2

680

7T

0.6

20.7

26.2

1.3

980

8T

0.6

22.2

27.9

1.4

1,090

10T

0.6

25.3

31.2

1.5

1,300

12T

0.75

7 / 0.37

1.11

0.6

26.8

32.7

1.6

1,450

14T

0.6

28.4

34.5

1.7

1,650

16T

0.6

30.3

37.1

1.8

1,920

19T

0.6

32.7

39.7

1.9

2,180

24T

0.6

36.4

43.8

2.1

2,620

32T

0.6

42.3

50.1

2.3

3,350

2T

0.6

14.6

19.7

1.1

550

3T

0.6

15.6

20.7

1.1

650

4T

0.6

17.2

22.5

1.2

770

7T

0.6

21.8

27.3

1.4

1,100

0.6

23.4

29.1

1.5

1,220

0.6

26.7

32.6

1.6

1,460

12T

0.6

28.7

34.8

1.7

1,700

14T

0.6

30.0

36.8

1.8

1,980

16T

0.6

31.9

38.9

1.9

2,200

19T

0.6

34.6

41.8

2.0

2,510

24T

0.6

38.8

46.2

2.1

3,050

32T

0.6

44.7

52.7

2.4

3,860

2T

0.7

16.6

21.7

1.2

650

3T

0.7

17.7

23.0

1.2

780

4T

0.7

19.6

25.1

1.3

940

7T

0.7

24.9

30.8

1.5

1,380

0.7

26.7

32.6

1.6

1,520

0.7

30.9

37.7

1.8

1,980

12T

0.7

32.8

39.8

1.9

2,250

14T

0.7

34.3

41.5

2.0

2,500

16T

0.7

36.5

43.9

2.1

2,770

19T

0.7

40.0

47.6

2.2

3,230

24T

0.7

44.4

52.4

2.4

3,890

32T

0.7

51.6

60.2

2.7

5,030

2T

0.7

18.0

23.3

1.2

770

3T

0.7

19.2

24.5

1.3

930

4T

0.7

21.3

26.8

1.4

1,120

7T

0.7

27.5

33.6

1.6

1,740

8T

0.7

29.5

35.8

1.7

1,950

0.7

33.7

40.7

1.9

2,440

12T

0.7

35.7

42.9

2.0

2,780

14T

0.7

37.4

44.8

2.1

3,110

16T

0.7

40.3

47.9

2.2

3,530

19T

0.7

43.6

51.4

2.4

4,050

24T

0.7

48.9

57.3

2.6

5,000

32T

0.7

56.4

65.4

2.9

6,390

8T
10T

1.0

7 / 0.43

1.29

8T
10T

10T

46

1.5

2.5

Offshore Cable

7 / 0.53

7 / 0.67

1.59

2.01

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C) (Min.)
M /km

24.8

1,170

18.2

1,050

12.2

1,010

7.56

840

0.6/1kV RX
47 ~ 48
Earthing & Bonding wire

0.6/1kV UX

VFD Cable

Instrumentation &
Communication Cable

LV Power & Lighting Cable

Earthing & Bonding wire

Technical data

HV Power Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

Earthing & Bonding wire

CABLE DESIGNATION (P15)


0.6/1kV UX, RX

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Classification
1. Conductor

Construction detail

Code

Stranded tinned annealed copper wires as per IEC 60228, Class 2

RX EPR as per IEC 60092-351


2. Insulation

UX SHF2 as per IEC 60092-359


-

0.6/1KV RX

No. of
Conductor
Cores Nominal
Strand
Area
NO.
mm2 No. / mm

48

Offshore Cable

1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

7 / 0.43
7 / 0.53
7 / 0.67
7 / 0.85
7 / 1.04
7 / 1.35
7 / 1.70
7 / 2.14
7 / 2.52
19 / 1.78
19 / 2.14
19 / 2.52
37 / 2.03
37 / 2.25
37 / 2.52
61 / 2.25
61 / 2.52

Dia.
mm
1.29
1.59
2.01
2.55
3.12
4.05
5.10
6.42
7.56
8.90
10.70
12.60
14.21
15.75
17.64
20.25
22.68

Insulation color : Yellow/Green (Green base with yellow strip) or Green

Thickness
Overall diameter
of
TolerNominal
Insulation
ance
mm
mm
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.6
1.6
1.6
1.8
2.0
2.2
2.4

4.8
5.1
5.6
6.2
6.7
7.7
8.8
10.8
12.0
13.8
16.2
18.1
19.8
21.9
24.3
27.5
30.5

0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.8
0.9
0.9
1.0
1.1
1.2
1.3
1.4
1.5

Conductor Insulation
Resistance Resistance
(at 20C) (Max.) (at 20C) (Min.)
kg / km
/km
M /km
Cable
Weight

38
46
59
79
101
150
210
330
440
580
820
1,090
1,350
1,650
2,050
2,670
3,320

18.2
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

20
18
16
14
12
10
8
8
7
7
6
5
5
5
5
5
5

49 ~ 51

0.6/1kV(1.8/3kV) BFOU(VFD)
52 ~ 52

Earthing & Bonding wire

0.6/1kV(1.8/3kV) RFOU(VFD)

VFD Cable

Instrumentation &
Communication Cable

LV Power & Lighting Cable

VFD Cable

Technical Information

HV Power Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

VFD Cable

CABLE DESIGNATION
0.6/1kV(1.8/3kV) RFOU(VFD]

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Classification
1. Conductor
2. Insulation

Construction detail

Code

Stranded tinned annealed copper wires as per IEC 60228, Class 2

EPR as per IEC 60092-351


- Insulated cores shall be cabled.

3. Cabling

- Flame retardant & non-hygroscopic fillers may be used .


- Suitable tape(s) may be applied on the cabled core.

0.6/1kV(1.8/3kV) RFOU(VFD)

4. Inner covering

50

Offshore Cable

Flame retardant halogen free thermoset compound

(VFD) CU/PS tape


- Braid of tinned copper wire

5. Armor (Screen)

- Coverage density of braid shall be not less than 100%.


- A suitable separator tape(s) may be applied over the armor.

6. Sheath
7. Core identification

- SHF2 or SHF Mud as per IEC 60092-359


- Outer sheath color : Black
3C+3E : Black, White, Red + G/Y (Earth core)

Note.
Flexible cable (Class5 Conductor) can be supplied

NEK-606 (2004), IEC 60092-350, 353, 354, 376

mm

25

7 / 2.14

6.42

2.2

3E

7 / 1.04

3.12

1.0

3C

35

7 / 2.52

7.56

2.2

3E

7 / 1.04

3.12

1.0

3C

50

19 / 1.78

8.90

2.2

3E

10

7 / ,1.35

4.05

1.0

3C

70

19 / 2.14

10.70

2.2

3E

16

7 / 1.70

5.10

1.0

3C

95

19 / 2.52

12.60

2.4

3E

16

7 / 1.70

5.10

1.0

3C

120

37 / 2.03

14.21

2.4

3E

25

7 / 2.14

6.42

1.2

3C

150

37 / 2.25

15.75

2.4

3E

25

7 / 2.14

6.42

1.2

3C

185

37 / 2.52

17.64

2.4

3E

35

7 / 2.52

7.56

1.2

3C

240

61 / 2.25

20.25

2.4

3E

50

19 / 1.78

8.90

1.4

26.8

33.0

29.8

32.8

36.7

42.0

45.5

49.3

53.4

59.0

mm

36.6

39.8

44.1

49.8

53.5

57.7

62.0

68.2

Tolerance
mm
1.6

1.8

1.9

2.1

2.3

2.4

2.6

2.8

3.0

Cable
Weight
Approx.
kg / km

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C) (Min.)
M /km

2,070

0.734

830

3.110

790

0.529

730

3.110

790

0.391

640

1.840

640

0.270

550

1.160

530

0.195

510

1.160

530

0.154

460

0.734

510

0.126

420

0.734

510

0.100

380

0.529

440

0.076

340

0.391

440

2,630

3,270

4,300

5,490

6,690

7,800

9,420

11,900

LV Power & Lighting Cable

No. / mm

3C

Nominal

Overall diameter

Instrumentation &
Communication Cable

Dia.

Nominal
dia.
inner
covering
mm

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm

VFD Cable

No.

Conductor
Nominal
Area
mm2

Technical Information

No. of
Cores

HV Power Cable

CABLE TYPE : 0.6/1kV(1.8/3kV) RFOU(VFD)

Offshore Cable

51

VFD Cable

CABLE DESIGNATION
0.6/1kV(1.8/3kV) BFOU(VFD)

APPLICATION STANDARD
- Design guide

: NEK-606 & IEC 60092-353

- Flame retardant

: IEC 60332-1 &


IEC 60332-3 Category A

- Fire resistance

: IEC 60331-21, 31

- Halogen content

: IEC 60754-1, 0.5%

- Cold bend / impact

: CSA 22.2 No.03 (-40 /-35 )

- Mud resistant

: NEK-606 (Mud type only)

- Smoke light transmittance

: IEC 61034, 60%

- Sunlight (UV) resistant

: UL 1581

CONSTRUCTION
Construction detail
Classification
Code
1. Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
2. Fire resisting layer
Mica/glass tape
B
3. Insulation
EPR as per IEC 60092-351
- Insulated cores shall be cabled.

4. Cabling

- Flame retardant & non-hygroscopic fillers may be used .

0.6/1kV(1.8/3kV) BFOU(VFD)

- Suitable tape(s) may be applied on the cabled core.

52

Offshore Cable

5. Inner covering

Flame retardant halogen free thermoset compound

(VFD) CU/PS tape


6. Armor (Screen)

- Braid of tinned copper wire

- Coverage density of braid shall be not less than 100%


- A suitable separator tape(s) may be applied over the armor.

7. Sheath
8. Core identification

- SHF2 or SHF Mud as per IEC 60092-359

- Outer sheath color : Black


3C+3E : Black, White, Red + G/Y (Earth core)

Note.
Flexible cable (Class5 Conductor) can be supplied

NEK-606 (2004), IEC 60092-350, 353, 354, 376

mm

3C

25

7 / 2.14

6.42

2.2

3E

7 / 1.04

3.12

1.0

3C

35

7 / 2.52

7.56

2.2

3E

7 / 1.04

3.12

1.0

3C

50

19 / 1.78

8.90

2.2

3E

10

7 / 1.35

4.05

1.0

3C

70

19 / 2.14

10.70

2.2

3E

16

7 / 1.70

5.10

1.0

3C

95

19 / 2.52

12.60

2.4

3E

16

7 / 1.70

5.10

1.0

3C

120

37 / 2.03

14.21

2.4

3E

25

7 / 2.14

6.42

1.2

3C

150

37 / 2.25

15.75

2.4

3E

25

7 / 2.14

6.42

1.2

3C

185

37 / 2.52

17.64

2.4

3E

35

7 / 2.52

7.56

1.2

3C

240

61 / 2.25

20.25

2.4

3E

50

19 / 1.78

8.90

1.4

25.7

31.7

28.7

31.5

35.4

40.7

44.2

47.6

51.9

57.7

mm

34.9

38.5

42.6

48.3

52.2

55.8

60.5

66.7

Tolerance
mm
1.6

1.7

1.8

2.0

2.2

2.4

2.5

2.7

3.0

kg / km

Conductor
Resistance
(at 20C) (Max.)
/km

Insulation
Resistance
(at 20C) (Min.)
M /km

1,970

0.734

830

3.110

790

0.529

730

3.110

790

0.391

640

1.840

640

0.270

550

1.160

530

0.195

510

1.160

530

0.154

460

0.734

510

0.126

420

0.734

510

0.100

380

0.529

440

Cable
Weight

2,420

3,160

4,150

5,330

6,540

7,590

9.230

11.690

0.076

340

0.391

440

LV Power & Lighting Cable

No. / mm

Nominal

Overall diameter

Instrumentation &
Communication Cable

Dia.

Nominal
dia.
inner
covering
mm

Earthing & Bonding wire

Strand

Thickness
of
Insulation
mm

VFD Cable

No.

Conductor
Nominal
Area
mm2

Technical Information

No. of
Cores

HV Power Cable

CABLE TYPE : 0.6/1kV(1.8/3kV) BFOU(VFD)

Offshore Cable

53

Technical Information

1. ELECTRICAL DATA
2. VOLTAGE RATING SELECTION
3. TEST METHODS & EQUIPMENT
4. INSTALLATION RECOMMENDATIONS
5. CORE IDENTIFICATION

54

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

HV Power Cable

ELECTRICAL DATA
1. Current rating for continuous

0.75
1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

Two core

14
17
21
30
40
51
71
95
125
155
190
240
290
340
385
440
520
590

Three core & four core


10
12
15
21
29
36
50
67
89
105
135
170
205
240
270
305
365
415

11
13
18
25
34
43
60
81
105
135
165
200
249
288
331
177
444
511

LV Power & Lighting Cable

Single core

Instrumentation &
Communication Cable

Nominal cross-sectional Area


mm2

NOTES)

I1

Where, I1 : Current for single core cable

N3

N : Number of cores

Maximum conductor
temperature
90

18
16
14
13
12
12
11
10
10
9
8

12
11
10
9
9
8
8
7
7
6
6

10
9
8
7
7
7
6
6
5
5
5

5
7
9
12
14
16
19
24
30
37
44

2.5mm2 (A)

1.5mm2 (A)

VFD Cable

1.0 mm2 (A)

No. of cores

Technical Information

I=

Earthing & Bonding wire

1. Maximum permissible service temperature of the conductor is 90


2. The current ratings given above are based on an ambient air temperature of 45
3. The current ratings given above are for 6 cables of less bunched or laid together in flat formation.
When more than 6 cables are bunched or laid close together, the current ratings given above should
be multiplied correction factor 0.85.
In case of cables not being loaded simultaneously, consideration of the actual loading appertaining is permitted
4. For cables with more than 4 core cables, the current ratings are given by the Formula;

Correction factors for various ambient air temperature


35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Offshore Cable

55

Technical Information
2. Capacitance, Inductance, Reactance, Impedance Data
CABLE TYPE : 3.6/6kV RFOU, 3.6/6kV RFCU, 3.6/6kV RFBU
Multi core cable
Single core cable
Nominal Capacitance
Capacitance Inductance Reactance Reactance Impedance Impedance
Inductance
Reactance
Reactance
Impedance
Impedance
Area
C
C
L
X
X
Z
Z
L
X
X
Z
Z
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
mm2

/km

mH / km

/km

/km

10
16
25
35
50
70
95
120
150
185
240
300

0.247
0.284
0.328
0.362
0.408
0.466
0.528
0.581
0.624
0.695
0.742
0.770

0.458
0.434
0.409
0.393
0.375
0.358
0.343
0.332
0.326
0.317
0.310
0.305

0.144
0.136
0.128
0.123
0.118
0.112
0.108
0.104
0.102
0.099
0.097
0.096

0.173
0.164
0.154
0.148
0.142
0.135
0.129
0.125
0.123
0.119
0.117
0.115

/km

2.351
1.485
0.945
0.686
0.512
0.362
0.273
0.224
0.193
0.165
0.140
0.126

/km

/km

mH / km

/km

/km

/km

/km

2.353
1.488
0.949
0.691
0.518
0.370
0.282
0.234
0.205
0.177
0.154
0.141

0.247
0.284
0.328
0.362
0.408
0.466
0.528
0.581
0.624
0.695
0.742
-

0.324
0.306
0.290
0.281
0.270
0.260
0.252
0.246
0.242
0.237
0.234
-

0.102
0.096
0.091
0.088
0.085
0.082
0.079
0.077
0.076
0.074
0.073
-

0.122
0.115
0.109
0.106
0.102
0.098
0.095
0.093
0.091
0.089
0.088
-

2.348
1.482
0.940
0.680
0.506
0.354
0.263
0.213
0.181
0.151
0.125
-

2.349
1.484
0.942
0.683
0.509
0.358
0.268
0.219
0.187
0.159
0.134
-

CABLE TYPE : 6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU


Multi core cable
Single core cable
Nominal Capacitance
Inductance Reactance Reactance Impedance Impedance Capacitance Inductance Reactance Reactance Impedance Impedance
Area
C
C
L
X
X
Z
Z
L
X
X
Z
Z
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
mm2

/km

mH / km

/km

/km

16
25
35
50
70
95
120
150
185
240
300

0.288
0.261
0.278
0.321
0.365
0.411
0.450
0.484
0.535
0.591
0.651

0.450
0.425
0.407
0.390
0.370
0.355
0.346
0.337
0.330
0.321
0.311

0.141
0.134
0.128
0.123
0.116
0.111
0.109
0.106
0.104
0.101
0.098

0.170
0.160
0.153
0.147
0.140
0.134
0.130
0.127
0.124
0.121
0.117

/km

1.486
0.945
0.687
0.513
0.363
0.275
0.226
0.195
0.167
0.143
0.128

/km

/km

mH / km

/km

/km

/km

/km

1.489
0.950
0.692
0.520
0.371
0.284
0.237
0.207
0.181
0.158
0.143

0.288
0.261
0.287
0.321
0.365
0.411
0.450
0.484
0.535
0.591
-

0.335
0.316
0.305
0.292
0.280
0.270
0.263
0.258
0.251
0.245
-

0.105
0.099
0.096
0.092
0.088
0.085
0.083
0.081
0.079
0.077
-

0.126
0.119
0.115
0.110
0.106
0.102
0.099
0.097
0.095
0.092
-

1.483
0.941
0.681
0.507
0.355
0.265
0.215
0.183
0.153
0.127
-

1.484
0.943
0.684
0.511
0.360
0.271
0.222
0.190
0.162
0.137
-

CABLE TYPE : 8.7/15kV RFOU, 8.7/15kV RFCU, 8.7/15kV RFBU


Multi core cable
Single core cable
Nominal Capacitance
Capacitance Inductance Reactance Reactance Impedance Impedance
Inductance
Reactance
Reactance
Impedance
Impedance
Area
C
C
L
X
X
Z
Z
L
X
X
Z
Z
50 Hz
60 Hz
50Hz
60Hz
50 Hz
60 Hz
50 Hz
60 Hz
mm2

/km

mH / km

/km

/km

25
35
50
70
95
120
150
185
240
300

215
0.235
0.261
0.295
0.330
0.360
0.386
0.424
0.468
0.514

0.443
0.424
0.406
0.386
0.371
0.362
0.353
0.341
0.332
0.324

0.139
0.133
0.128
0.121
0.117
0.114
0.111
0.107
0.104
0.102

0.167
0.160
0.153
0.145
0.140
0.137
0.133
0.129
0.125
0.122

56

Offshore Cable

/km

0.946
0.688
0.515
0.365
0.277
0.229
0.198
0.169
0.145
0.131

/km

/km

mH / km

/km

/km

/km

/km

0.951
0.693
0.522
0.374
0.288
0.241
0.211
0.184
0.161
0.147

0.215
0.235
0.261
0.295
0.330
0.360
0.386
0.424
0.468
-

0.344
0.330
0.316
0.302
0.290
0.281
0.275
0.267
0.260
-

0.108
0.104
0.099
0.095
0.091
0.088
0.086
0.084
0.082
-

0.130
0.125
0.119
0.114
0.109
0.106
0.104
0.101
0.098
-

0.942
0.682
0.508
0.357
0.267
0.217
0.185
0.156
0.130
-

0.945
0.686
0.513
0.363
0.274
0.225
0.194
0.166
0.144
-

NEK-606 (2004), IEC 60092-350, 353, 354, 376

CABLE TYPE : 0.6/1kV(1.8/3kV) RFOU(VFD)


Nominal
Area

Capacitance
C

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

Impedance
Z
50 Hz

Impedance
Z
60 Hz

No.

mm2

/km

mH / km

/km

/km

3C
3E
3C
3E
3C
3E
3C
3E
3C
3E

95
16
120
25
150
25
185
35
240
50

0.582

0.255

0.080

0.096

0.264

0.269

0.667

0.249

0.078

0.094

0.213

0.219

0.715

0.244

0.077

0.092

0.181

0.159

0.736

0.238

0.075

0.090

0.151

0.159

0.794

0.233

0.073

0.088

0.125

0.134

Impedance
Z
50 Hz

Impedance
Z
60 Hz

/km

/km

LV Power & Lighting Cable

No. of
Cores

HV Power Cable

Multi core cable

CABLE TYPE : 0.6/1kV(1.8/3kV) BFOU(VFD)


Nominal
Area

Capacitance
C

Inductance
L

Reactance
X
50 Hz

Reactance
X
60 Hz

No.

mm2

/km

mH / km

/km

/km

3C
3E
3C
3E
3C
3E
3C
3E
3C
3E

95
16
120
25
150
25
185
35
240
50

0.550

0.262

0.082

0.099

0.264

0.270

0.603

0.255

0.080

0.096

0.214

0.220

0.658

0.250

0.079

0.094

0.182

0.189

0.715

0.244

0.077

0.092

0.152

0.160

0.770

0.238

0.075

0.090

0.126

0.135

/km

/km

Earthing & Bonding wire

No. of
Cores

Instrumentation &
Communication Cable

Multi core cable

CABLE TYPE : 0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU


Multi core cable
Single core cable )
Nominal Capacitance
Capacitance Inductance Reactance Reactance Impedance Impedance
Inductance
Reactance
Reactance
Impedance
Impedance
Area
C
C
L
X
X
Z
Z
L
X
X
Z
Z
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
mH / km

/km

/km

0.204
0.242
0.283
0.339
0.407
0.504
0.510
0.575
0.591
0.685
0.716
0.800
0.800
0.805
0.822
0.849

0.564
0.525
0.488
0.460
0.423
0.392
0.373
0.356
0.342
0.325
0.315
0.306
0.306
0.294
0.289
0.288

0.177
0.165
0.153
0.144
0.133
0.123
0.119
0.112
0.108
0.102
0.099
0.096
0.096
0.092
0.091
0.091

0.213
0.198
0.184
0.173
0.160
0.148
0.140
0.134
0.129
0.123
0.119
0.115
0.115
0.111
0.109
0.109

/km

15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.684
0.510
0.359
0.270
0.220
0.220
0.161
0.136
0.122

/km

15.558
9.642
5.996
3.969
2.352
1.486
0.946
0.688
0.515
0.365
0.278
0.229
0.229
0.172
0.149
0.136

/km

mH / km

/km

/km

0.305
0.345
0.379
0.435
0.477
0.500
0.589
0.685
0.705
0.715
0.770
0.834
0.834
0.834
0.848
0.848

0.358
0.331
0.311
0.291
0.274
0.258
0.256
0.249
0.247
0.238
0.236
0.231
0.231
0.231
0.230
0.229

0.112
0.104
0.098
0.091
0.086
0.081
0.080
0.078
0.078
0.075
0.074
0.073
0.073
0.073
0.072
0.072

0.135
0.125
0.117
0.110
0.103
0.097
0.097
0.094
0.093
0.090
0.089
0.087
0.087
0.087
0.087
0.086

/km

/km

15.557
9.640
5.994
3.967
2.348
1.481
0.939
0.679
0.505
0.352
0.262
0.211
0.211
0.150
0.124
0.109

VFD Cable

/km

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300

15.557
9.641
5.994
3.967
2.348
1.482
0.941
0.681
0.507
0.356
0.266
0.217
0.217
0.158
0.133
0.119

Technical Information

mm2

* Reactance for 1-conductor cables given at Three-foil formation

Offshore Cable

57

Technical Information
CABLE TYPE : 0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU
Multi core cable
Single core cable )
Nominal Capacitance
Inductance Reactance Reactance Impedance Impedance Capacitance Inductance Reactance Reactance Impedance Impedance
Area
C
C
L
X
X
Z
Z
L
X
X
Z
Z
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
mm2

/km

mH / km

/km

/km

/km

/km

/km

mH / km

/km

/km

/km

/km

1.5

0.172

0.575

0.181

0.217

15.557

15.558

0.278

0.388

0.122

0.146

15.557

15.557

2.5

0.201

0.539

0.168

0.203

9.641

9.642

0.309

0.359

0.113

0.135

9.640

9.641

0.234

0.502

0.158

0.189

5.995

5.996

0.345

0.335

0.105

0.126

5.994

5.994

0.277

0.469

0.147

0.177

3.968

3.970

0.385

0.313

0.098

0.118

3.967

3.967

10

0.331

0.432

0.136

0.163

2.350

2.352

0.435

0.292

0.092

0.110

2.348

2.349

16

0.405

0.403

0.127

0.152

1.485

1.487

0.500

0.274

0.086

0.103

1.482

1.483

25

0.437

0.381

0.120

0.144

0.944

0.947

0.527

0.267

0.084

0.101

0.940

0.941

35

0.493

0.362

0.114

0.137

0.684

0.688

0.556

0.258

0.081

0.097

0.679

0.682

50

0.515

0.350

0.110

0.132

0.511

0.516

0.589

0.255

0.080

0.096

0.505

0.508

70

0.604

0.330

0.104

0.124

0.360

0.366

0.695

0.245

0.077

0.092

0.353

0.356

95

0.632

0.319

0.100

0.120

0.270

0.278

0.715

0.243

0.076

0.091

0.262

0.267

120

0.705

0.309

0.097

0.117

0.221

0.230

0.758

0.237

0.074

0.089

0.212

0.218

150

0.698

0.305

0.096

0.115

0.190

0.200

0.758

0.237

0.075

0.089

0.180

0.187

185

0.725

0.299

0.094

0.113

0.161

0.173

0.782

0.236

0.074

0.089

0.151

0.159

245

0.749

0.294

0.092

0.111

0.137

0.150

0.807

0.234

0.073

0.088

0.125

0.134

300

0.778

0.291

0.091

0.110

0.123

0.137

0.820

0.232

0.073

0.088

0.110

0.120

* Reactance for 1-conductor cables given at Three-for foil formation

CABLE TYPE : 250V Instrument & communication cables.


unit

0.75mm2

1.0mm2

1.5mm2

2.5mm2

Individual screen

nF/km

100

100

120

120

Collective screen

nF/km

80

80

90

90

mH/km

0.75

0.73

0.68

0.68

Size
Mutual
capacitance

Inductance

58

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

Inductance & Reactance Data

3. Short circuit current rating


HV Power Cable

The short circuit currents quoted here are for cables operating normally at maximum conductor temperature of
85 . EPR insulation is actually capable of withstanding short-term Temperature up to 250
According to ICEA P-32-382 Curves based on formula

Is = A x 0.115 log

s : Short Circuit Current (kA)


A : Conductor area ( )
T1 : Operating temperature ( 85 )

LV Power & Lighting Cable

Where

(T2 + 234)
(T1 + 234)

T2 : Short Circuit temperature ( 250 )

: Short Circuit duration (sec)

T1 = 90, T2 = 250

Short circuit currents (kA)

Nominal
area
0.07

0.1

0.14

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.5

1.3

1.0

0.8

0.7

0.6

0.5

0.4

0.3

0.3

0.3

0.3

0.2

0.2

0.2

2.5

2.0

1.6

1.3

1.1

0.9

0.8

0.6

0.6

0.5

0.5

0.4

0.4

0.4

0.3

3.2

2.5

2.1

1.8

1.5

1.3

1.0

0.9

0.8

0.7

0.7

0.6

0.6

0.6

4.9

3.8

3.2

2.7

2.3

1.9

1.5

1.3

1.2

1.1

1.0

0.9

0.9

0.8

10

8.2

6.3

5.4

4.5

3.8

3.2

2.6

2.2

2.0

1.8

1.7

1.6

1.5

1.4

16

13.0

10.1

8.5

7.1

6.0

5.0

4.1

3.6

3.2

2.9

2.7

2.5

2.4

2.2

25

20.6

15.9

13.5

11.3

9.5

8.0

6.5

5.6

5.0

4.6

4.3

4.0

3.8

3.6

35

28.5

22.1

18.7

15.6

13.2

11.1

9.0

7.8

7.0

6.4

5.9

5.5

5.2

4.9

50

38.6

29.9

25.3

21.2

17.9

15.0

12.2

10.6

9.5

8.6

8.0

7.5

7.1

6.7

70

55.9

43.3

36.6

30.6

25.9

21.6

17.7

15.3

13.7

12.5

11.6

10.8

10.2

9.7

95

77.5

60.0

50.7

42.4

35.9

30.0

24.5

21.2

19.0

17.3

16.0

15.0

14.1

13.4

150

97.9

75.8

64.1

53.6

45.3

37.9

31.0

26.8

24.0

21.9

20.3

19.0

17.9

17.0

150

120.3

93.1

78.7

65.9

55.7

46.6

38.0

32.9

29.5

26.9

24.9

23.3

22.0

20.8

185

150.8

116.8

98.8

82.6

69.8

58.4

47.7

41.3

36.9

33.7

31.2

29.2

27.5

26.1

240

198.3

153.6

129.8

108.6

91.8

76.8

62.7

54.3

48.6

44.3

41.0

38.4

36.2

34.3

300

248.7

192.6

162.8

136.2

115.1

96.3

78.6

68.1

60.9

55.6

51.5

48.2

45.4

43.1

400

329.3

255.1

215.6

180.4

152.5

127.6

104.1

90.2

80.7

73.6

68.2

63.8

60.1

57.0

500

401.0

310.6

262.5

219.6

185.6

155.3

126.8 109.8

98.2

89.7

83.0

77.7

73.2

69.5

Earthing & Bonding wire

0.05

VFD Cable

0.03

Technical Information

mm2

Instrumentation &
Communication Cable

Duration of short circuit in second

Offshore Cable

59

Technical Information
4. Voltage drop
Calculate fomula
1) D.C. circuit
Rdc x 2L x I
V

Voltage drop rate =

2) A.C. circuit
Voltage drop rate of single-phase A.C.=
Voltage drop rate of three-phase A.C.=

Where L
I
V
Rdc

: Cable length (km)


: Current(A)
: Circuit Voltage(V)
: D.C. resistance at maximum rated
conductor temperature
(see following table)
Rac : A.C. resistance at maximum rated
conductor temperature
(see following table)
: Inductive voltage drop coefficient

x 100(%)

Rac x 2L x I
V
Rac x 2L x I
V

x x 100(%)
3

x 2

x x 100(%)

Voltage drop coefficient


CABLE TYPE : 3.6/6kV RFOU. 3.6/6kV RFCU, 3.6/6kV RFBU
Inductive voltage drop coefficient

R-dc
R-ac
Nominal R-dc
Area (at 20 ) (at 90 ) (at 90 )
2

mm

10
16
25
35
50
70
95
120
150
185
240

/km

1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762

/km

2.346
1.479
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972

Dielectric power factor (at at 60HZ & 90 Conductor temperature)

/km

100%

95%

90%

85%

80%

75%

70%

2.346
1.479
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.97
0.98
1.00
1.02
1.04
1.07
1.11
1.15
1.18
1.23
1.31

0.93
0.95
0.97
1.00
1.02
1.07
1.12
1.17
1.23
1.30
1.40

0.89
0.91
0.94
0.97
1.00
1.06
1.12
1.18
1.25
1.33
1.46

0.84
0.87
0.90
0.93
0.97
1.04
1.11
1.18
1.25
1.35
1.49

0.80
0.82
0.86
0.90
0.94
1.01
1.09
1.17
1.25
1.35
1.51

0.75
0.78
0.82
0.86
0.90
0.98
1.07
1.15
1.24
1.35
1.53

CABLE TYPE : 6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU


Inductive voltage drop coefficient

R-dc
R-ac
Nominal R-dc
Area (at 20 ) (at 90 ) (at 90 )
2

mm

16
25
35
50
70
95
120
150
185
240

/km

1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762

/km

1.479
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972

Dielectric power factor (at at 60HZ & 90 Conductor temperature)

/km

100%

95%

90%

85%

80%

75%

70%

1.479
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

0.99
1.00
1.02
1.04
1.08
1.12
1.16
1.19
1.25
1.32

0.95
0.97
1.00
1.03
1.08
1.13
1.19
1.24
1.31
1.42

0.91
0.94
0.97
1.01
1.06
1.13
1.20
1.26
1.35
1.48

0.87
0.90
0.94
0.98
1.04
1.12
1.19
1.27
1.37
1.52

0.83
0.86
0.90
0.95
1.02
1.10
1.19
1.26
1.38
1.54

0.78
0.82
0.86
0.91
0.99
1.08
1.17
1.25
1.38
1.55

CABLE TYPE : 6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU


Inductive voltage drop coefficient

R-dc
R-ac
Nominal R-dc
Area (at 20 ) (at 90 ) (at 90 )
2

mm

25
35
50
70
95
120
150
185
240

60

/km

0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762

Offshore Cable

/km

0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972

Dielectric power factor (at at 60HZ & 90 Conductor temperature)

/km

100%

95%

90%

85%

80%

75%

70%

0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010

1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00

1.01
1.02
1.05
1.08
1.12
1.17
1.20
1.26
1.34

0.98
1.00
1.03
1.08
1.14
1.20
1.25
1.33
1.44

0.94
0.97
0.01
1.07
1.14
1.21
1.28
1.37
1.50

0.91
0.94
0.98
1.05
1.13
1.21
1.29
1.39
1.54

0.87
0.91
0.95
1.03
1.12
1.21
1.29
1.40
1.57

0.83
0.87
0.92
1.00
1.10
1.19
1.28
1.40
1.58

NEK-606 (2004), IEC 60092-350, 353, 354, 376

HV Power Cable

CABLE TYPE : 0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU


Inductive voltage drop coefficient

R-dc
R-ac
Nominal R-dc
Area (at 20 ) (at 90 ) (at 90 )
/km

/km

100%

95%

90%

85%

80%

75%

70%

12.2

15.6

15.6

1.00

0.95

0.91

0.86

0.81

0.76

0.71

2.5

7.56

9.64

9.64

1.00

0.96

0.91

0.86

0.81

0.76

0.71

4.70

5399

5.99

1.00

0.96

0.91

0.87

0.82

0.77

0.72

3.11

3.97

3.97

1.00

0.96

0.92

0.87

0.83

0.78

0.73

10

1.84

2.35

2.35

1.00

0.97

0.93

0.89

0.84

0.80

0.75

16

1.16

1.48

1.48

1.00

0.98

0.94

0.90

0.86

0.82

0.77

25

0.734

0.936

0.936

1.00

1.00

0.97

0.93

0.89

0.85

0.81

35

0.529

0.675

0.675

1.00

1.01

0.99

0.95

0.92

0.88

0.84

50

0.391

0.499

0.499

1.00

1.03

1.01

0.99

0.96

0.92

0.88

70

0.270

0.344

0.344

1.00

10.6

1.06

1.04

1.01

0.99

0.95

95

0.195

0.249

0.251

1.00

1.10

1.11

1.10

1.08

1.06

1.04

120

0.154

0.196

0.198

1.00

1.13

1.15

1.16

1.15

1.13

1.11

150

0.126

0.161

0.164

1.00

1.17

1.20

1.21

1.21

1.21

1.19

185

0.100

0.128

1.131

1.00

1.21

1.27

1.29

1.31

1.31

1.30

240

0.0762

0.0972

0.1010

1.00

1.29

1.37

1.42

1.45

1.46

1.47

300

0.0607

0.0774

0.0820

1.00

1.36

1.48

1.55

1.59

1.63

1.65

Instrumentation &
Communication Cable

/km

1.5

Earthing & Bonding wire

mm2

LV Power & Lighting Cable

Dielectric power factor (at 60Hz & 90 )

CABLE TYPE : 0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU


Inductive voltage drop coefficient

R-dc
R-ac
Nominal R-dc
Area (at 20 ) (at 90 ) (at 90 )
/km

/km

/km

100%

95%

90%

85%

80%

75%

70%

1.5

12.2

15.6

15.6

1.00

0.95

0.91

0.86

0.81

0.76

0.71

2.5

7.56

9.64

9.64

1.00

0.96

0.91

0.86

0.81

0.76

0.72

4.70

5.99

5.99

1.00

0.96

0.91

0.87

0.82

0.77

0.72

3.11

3.97

3.97

1.00

0.96

0.92

0.87

0.83

0.78

0.73

10

1.84

2.35

2.35

1.00

0.97

0.93

0.89

0.84

0.80

0.75

16

1.16

1.48

1.48

1.00

0.98

0.94

0.90

0.86

0.82

0.77

25

0.734

0.936

0.936

1.00

1.00

0.97

0.93

0.89

0.85

0.81

35

0.529

0.675

0.675

1.00

1.01

0.99

0.96

0.92

0.88

0.84

50

0.391

0.499

0.499

1.00

1.03

1.02

0.99

0.96

0.92

0.89

70

0.270

0.344

0.344

1.00

1.06

1.06

1.04

1.02

0.99

0.96

95

0.195

0.249

0.251

1.00

1.10

1.11

1.10

1.09

1.07

1.04

120

0.154

0.196

0.198

1.00

1.13

1.16

1.16

1.15

1.14

1.12

150

0.126

0.161

0.164

1.00

1.17

1.21

1.22

1.22

1.21

1.20

185

0.100

0.128

0.131

1.00

1.22

1.27

1.30

1.31

1.32

1.31

240

0.0762

0.0972

0.1010

1.00

1.29

1.38

1.43

1.46

1.48

1.48

300

0.0607

0.0774

0.0820

1.00

1.37

1.48

1.55

1.60

1.63

1.65

Offshore Cable

Technical Information

mm

VFD Cable

Dielectric power factor (at 60Hz)

61

Technical Information
VOLTAGE RATING SELECTION
Selection cable for A.C systems
Recommended (kV)

System voltage (kV)


Supply
system

Supply
category

Phase to earth
(Uo)
Above

3-Phase 4-Wire

A&B

3-Phase 4-Wire

3-Phase 3-Wire

A&B

3-Phase 3-Wire

2-Phase 3-Wire
or 2-Phase 4-Wire

A&B

2-Phase 3-Wire
or 2-Phase 4-Wire

1-Phase 3-Wire

A&B

1-Phase 3-Wire

1-Phase 2-Wire
or
1-Phase 1-Wire

0.15
0.15
0.6
1.9
3.8
6.35
8.7
0.15
0.15
-

Up to and
including
0.15
0.6
0.15
0.6
1.9
3.8
6.35
8.7
12.7
0.15
0.6
0.15
0.6
-

Phase to phase
(U)
Above
0.25
0.15
0.25
3.3
6.6
11
15
0.15
0.6
1.9
3.3
6.6
11
0.15
0.6
0.25
0.25
0.15
0.6
1.9
3.3
6.6
11

Up to and
including

Maximum
sustained
voltage
(Um)

0.25
1
0.15
0.6
0.25
1
3.3
6.6
11
15
22
0.15
0.6
1.9
3.3
6.6
11
15
0.21
0.84
0.15
0.a6
1.9
0.25
1
0.15
0.6
0.15
0.6
1.9
3.3
6.6
11
15

0.28
1.2
0.28
1.2
3.6
7.2
12
17
24
3.6
7.2
12
17.5
0.28
1.2
3.6
7.2
12
17.5

IEC
standard

BS
standards

UO / U

UO / U

0.15 / 0.25
0.6 / 1
0.15 / 0.25
0.6 / 1
0.15 / 0.25
0.6 / 1
1.8 / 3
3.6 / 6
6 / 10
8.7 / 15
12 / 20
0.15 / 0.25
0.6 / 1
1.8 / 3
3.6 / 6
6 / 10
8.7 / 15
12 / 20
0.15 / 0.25
0.6 / 1
0.15 / 0.25
0.6 / 1
1.8 / 3
0.15 / 0.25
0.6 / 1
0.15 /0.25
0.6 / 1
0.15 /0.25
0.6 / 1
1.8 / 3
3.6 / 6
6 / 10
8.7 / 15
12 / 20

0.15 / 0.25
0.6 / 1
0.15 / 0.25
0.6 / 1
0.15 / 0.25
0.6 / 1
1.9 / 3.3
3.8 / 6.6
6.35 / 11
12.7 / 22
0.15 / 0.25
0.6 / 1
1.9 / 3.3
3.8 / 6.6
6.35 / 11
11 / 11
12.7 / 22
0.15 / 0.25
0.6 / 1
0.15 / 0.25
0.6 / 1
1.9 / 3.3
0.15 / 0.25
0.6 / 1
0.15 / 0.25
0.6 / 1
0.15 / 0.25
0.6 / 1
19. / 3.3
3.8 / 6.6
6.35 / 11
12.7 / 22

Note) The rated voltage of the cable for a given application shall be suitable for the operating condition in the system in which the cable
is used. To facilitate the choice of the cable, the system are divided into the following three categories
Category A : This category comprises those systems in which any phase conductor than comes in contact with earth or an earth
conductor , is automatically disconnected from the system within 1 minute.
Category B : This category comprises those systems in which, under fault conditions, are operated for a short time, not exceeding
8 hours on any occasion, faults in any year should not exceed 125 hours.
Category C : This category comprises all systems which do not fall into categories A and B.

62

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

2. Fire resistant test

IEC 60332-3. CAT. A (VTFT)

IEC 60331 (at 750

3. Cold test (Bending / Impact)

4. Halogen content test

LV Power & Lighting Cable

1. Flame retardant test

HV Power Cable

TEST METHODS & TEST EQUIPMENT

Earthing & Bonding wire

Instrumentation &
Communication Cable

1000 )

CSA C22.2 No.03 (-40

-35

IEC 60754-1,2 Test

6. Oxygen index test

IEC 61034-1,2 Test

ASTM D 2863

Technical Information

VFD Cable

5. Smoke emission test

Offshore Cable

63

Technical Information
7. Mud resistant test
Mud resistant cables shall be designed with sheathing compounds suitable for installation and operation in
contact with MUD unless otherwise specified. Type SHF Mud.
The variation in the tensile strength and elongation at break values from those values obtained on the
unaged sample shell not exceed 25%.
The volume swell and weight increase shell not exceed 20%and 15% respectively.

1) IRM 903 requirements


The variation in the tensile strength and elongation at break values from those values
obtained on the unaged sample shell not exceed 30%.

2) Drilling fluid mud test requirements for sheathing compound SHF mud
Test shall be carried out on dumbbells as specified in IEC 60092-359 Table
fluids and conditions shall be as given in Table 1.

Tesa fluid
Mineral oil type-IRM 903

Temperature

clause 3 except that the test

Duration

100

7d

Calcium Bromide Brine (Water based)

70

56d

Carbo Sea (oil based)

70

56d

8. Oil resistance
All thermoset sheathed cables shall be suitable for an oil production installation. The oil resistance
properties shall be demonstrated by a test according to IEC 60092-359 Table clause 3, type SHF2.

64

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

HV Power Cable

INSTALLATION RECOMMENDATIONS
The following installation recommendations are in accordance with IEC regulation and practice.
Different regulations may apply in other countries.

LV Power & Lighting Cable

1. Minimum cable bending radius


The bending radius for the installation of cables should be not less than the values given as follows;
Type of cable

Minimum bending radius

Up to
1.8/3kV

3.6/6kV
above

25mm

4XD

25mm

6XD

Metal braid screened or armored

6XD

Tape screened

8XD

Single core

12 X D

3-core

9XD

Instrumentation &
Communication Cable

Unarmored or unbraided

r
D

Earthing & Bonding wire

Notes) D : Overall diameter of cable

2. Installation temperature
Minimum recommended installation temperature for cables shall be -20

3. Pulling tension
The cable pulling tension during installation can be estimated by means of the following formula:
VFD Cable

p=5kg x total cross section of conductors in the armoured cable or,


p=2.5kg x total cross section of conductors in the unarmoured cable

Technical Information

Additional tension will be supplied from the braid and the insulation and sheathing compound.

Offshore Cable

65

Technical Information
4. Explosion risk areas
1) Areas
The areas on board are usually classified in two main categories with regards to the explosion risk :
Hazardous areas : Areas in which explosive gas-air mixtures are, or may be expected to be,present in
quantities such as to require special precautions for the construction and use of electrical apparatus.
Safe areas(non-hazardous areas ) : Areas n which explosive gas-air mixtures are not expected to be,
present in quantities such as to required special precautions for the construction and use of electrical
apparatus.
A hazardous area is divided into three zones :
Zone 0 : in which an explosive gas-air mixture is continuously present or present for long periods.
Zone 1 : in which an explosive gas-air mixture is likely to occur in normal operation
Zone 2 : in which an explosive gas-air mixture is not likely to occur, and if occurs it will only exist for a short time

2) Installation of cables
For cables to be used in zone 0 and zone 1, one of the following types of protection is required:
A non-metallic outer sheath in combination with braiding or other metallic covering for earth fault
detection and mechanical protection. A non-metallic outer sheath is, however, not required if the
screen or armouring consists of a corrosion resistant bronze alloy.
A lead sheathing in addition to further mechanical protection, for example armour braiding or
non-metallic impervious sheath.
For mineral insulated cables, a copper or stainless steel sheath.
Single core cables in installations with A.C or D.C. current with a high ripple content should be of types
without screen of armouring. Where mechanical damage is possible, such cables should otherwise be
mechanically protected or installed in ducts or similar.
For installations in zone 2, cables without screen or armour can be used.

66

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

HV Power Cable

5. Earthing of metal coverings of cables


1) General requirements

LV Power & Lighting Cable

All metal coverings of cables, armouring or shielding shall be earthed. Earthing must be provided at both
ends except for final sub-circuits where earthing at only one end(the supply end)is sufficient.
Earthing at one end is permitted where it is required for technical or safety reasons, control and
instrumentation cables, mineral insulated cables, intrinsically safe circuits, control circuits etc.
Metal covering of single core cable for AC and single core cable for DC with ripple content exceeding 10%
and having a current rating exceeding 20A is to be earthed at one and only.
when sing;e core cables for AC and DC with ripple content higher than 10% are installed in or passing
through hazardous areas, the metal screen or armour is to be earthed inside the hazardous area to avoid
dangerous potential between screen armour and earthed part of the installation

Instrumentation &
Communication Cable

2) Cross section of earth connections


Earth connections for metal coverings shall be carried out with conductors having cross sectional areas
related to the cross sectional areas of the phase conductors and the current ratings of the cables, or at
least the same cross sectional areas as the metal covering itself.

3) Earthing through metal clamps etc.


Earthing & Bonding wire

Metal coverings of cables may be earthed through clamps. The clamps must grip the metal covering of the
cable and must be connected to the hull and provide a good conductive connection between the metal
covering and the hull. The metal clamps must be corrosion resistant.

4) Earthing through cable glands

VFD Cable

The metal coverings of cables may be earthed by means of glands intended for the purpose and so
designed as to ensure an effective earth connection. The glands shall be firmly attached to, and in
effective electrical contact with, a metal structure earthed in accordance with these regulations.

5) Earthing of metal pipes, conduits etc.

Offshore Cable

Technical Information

Metal pipes and cable conduits are to be earthed. Pipes and conduits may be earthed by being screwed
into a metal enclosure, or by nuts in both sides of the wall of metallic enclosure, provided that the surface
is clean and free from rust, scale or print.
Comments : For intrinsically safe circuits it is important to separate the earth conductor from the
protective earthing. The resistance between a zener barrier earth and protective earth must be max.
1ohm and preferably less than. 0.1ohm to avoid that possible fault current does not lead to a potential
increase in the system.

67

Technical Information
6. Fixing of cables
Cables are to be suitably fixed to the supports. In order to guard against the effects of
electrodynamics forces developing on the occurrence of a short circuit, single core cables should
be firmly fixed by using supports of a strength adequate to withstand forces corresponding to the values of
prospective short circuit current.
The requirement concerning fixing can normally be fulfilled when the cables are clamped as follows:
For cables entering enclosures and conduits the nearest clamp is to be placed at a minimum distance
from the entry of 10 times the diameter the cable concerned from the entry.
At other points the distance between the clamps must not exceed the in the following table:

External diameter of cable (mm)


Above

Up to

Spacing of fixing points (mm)


Cables without Metal braid or
armor

Cables with copper, bronze


or steel braid or armor

200

250

13

250

300

12

20

300

350

20

30

350

400

30

400

450

7. Mechanical protection of cables


Cables are to be installed in such a way that they are not subject to damaging mechanical stressed.
where this can not be obtained the cables are to be protected. Unless the cable itself(for example armour or
sheath) provides adequate protection the cables should be:
Enclosed in suitable conduits or casings
covered by steel pipes or profiles
Steel pipes in which the cables are run
in areas where there is an exceptional risk of mechanical damage, for example in cargo hold area or different
storage areas, the cables always have to be protected, even when the cables are armoured.
The thickness of the protective conduits must be at least 4mm.
The wall thickness of the protective conduit must be at least 2mm.
Cables lay on aluminum supports may have a corresponding protection of aluminum.
the thickness must be at least 4mm.
Metal casing used for mechanical protection of cables should be efficiently protected against corrosion.

68

Offshore Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

Cables must at least meet the flame retardant requirements. On board passenger ships, cargo-ships
and mobile offshore units, where requirements are considered to be satisfied if the cables have
characteristics complying withe the cable bunch test IEC-Publication 60332-3, or fire stops are installed in accordance with
the following recommendations:When cable complying with single-cable test, but not the cable-bunch-test, are installed,
fire stops are to be provided in enclosed or semi-enclosed spaces except for cargo rooms and tunnels in cargo areas.

HV Power Cable

8. Installation of cables for fire properties

a) For vertical cable runs


LV Power & Lighting Cable

- with a max. distance between fire stops of two decks or 6 meters, unless installed in totally enclosed cable ducts
- at the main and emergency switchboard
- where cables enter into an engine control room
- at centralized control panels for propulsion machinery and essential auxiliaries
- at the entrance to cables ducts

b) For horizontal cable runs.


- Fire stops shall be as specified in item a) above but the maximum. distance between fire stops may be increased to 14m.

Instrumentation &
Communication Cable

When choosing cable types special attention should be paid to reduce possible damage due to corrosion in case of a fire.
Non-halogen free cables(materials)will give off corrosive gases during a fire.
The corrosion effect depends on the amount of halogens in the materials used.
Flame retardant cables are to give characteristics complying with the test requirements in IEC-Publication 60332-1, with
amendments.
Fire resistant cables are to give characteristics complying with the requirements in IEC-Publication 60331.

9. Intrinsically safe installations

Earthing & Bonding wire

Cables and flexible cables for intrinsically safe circuits must have screen or similar of a conducting material and the
outer sheath must be of an insulating material. A non-metallic outer sheath is, however, not required if the screen or
armour consists of a corrosion resistant bronze alloy. Where there is no danger of interference from the external
electrical or magnetic fields, short flexible cables may be used without screen.
a) Associated equipment
Associated equipment(e.g.power supply units) shall be situated in a safe area or has protection as mentioned in
"Explosion risk areas."
b) Connection of equipment
Within limitations laid down in 3., ordinary non-explosion protected equipment may be connected to intrinsically safe
equipment, provided that it is designed to meet regulations in other respects.

VFD Cable

c) Compliance with any limitations in the certificate


With intrinsically safe circuits special considerations must be given to ensure that the circuits characteristics
(including connected equipment, cables, conductors etc.) satisfy any limitations in the test certificate.
Such limitations may be maximum values for capacitance and inductance etc. It is pointed out there is a danger of
damage to i.s equipment when using normal equipment for insulation testing
d) Adjacent location
Conductors for i.s safe circuits and conductors for non-i.s safe circuits shall not be run together in the same cable,
flexible cable, conduit, cables bunch etc.

Technical Information

e) Protection against electrical and magnetic fields


Where i.s circuits are exposed to magnetic or electrical field that may destroy the intrinsic safety of the system.
Precautions must be taken during installation. Such precautions may be:
- cables for i.s circuits and non-i.s circuits to be installed a minimum distance of 50mm apart.
The minimum distance to heavy current cables using D.C with a high ripple content should be 300mm.
- cables for i.s circuits and non-i.s circuits to be separated panel of conducting material which is earthed.
- cables for i.s circuits to have effective transposition.
f) Marking
The marking may be a marking plate or by colour marking of the cables when using colour marking, the colour should
be light blue.

Offshore Cable

69

Technical Information
CORE IDENTIFICATION
1. High voltage power cables
The individual cores shall be identified by the colored semi-conducting tape or colored ribbon tape run
longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows:
1 core : Off-white (grey)
3 core : Off-white (grey), Black, Red, or White, Red, Blue

2. Low voltage power and control cables


The insulated cores shall be identified by the color of insulation or by the number printed on insulated
cores; as follows
1) NEK-606 standard
1core : Off-white(Grey) or Black
2core : Off-white, Black
3core : Off-white, Black, Red
4core : Off-white, Black, Red, Blue or Black, Off-white, Red, Green.
5core and above core: white number on black insulation or black number on white insulation
Earth core : Green/Yellow (green base with yellow tracer)
2) CENELEC harmonization document HD 308 S2
2C

3C

Green / Yellow

Blue

2C

Blue

Brown

Brown

3C

Brown

Black

Grey

Blue

Brown

Black

Grey

Blue

Brown

Black

Grey

4C

Green / Yellow

Brown

Black

Grey

4C

5C

Green / Yellow

Blue

Brown

Black

Grey

5C

3. Instrumentation and communication cables


Each pair/triad shall be identified as follows.
- Pairs : Black, Light blue or Black, White
- Triads : Black, Light blue, Brown or Black, White, Red
For identification of multi-pair/triad cables, pair/triad are identified by lapping of the numbered tape or
by the number print directly on the each cores, and the number interval shall be 100mm or less.
The other color scheme may be applicable when purchaser required.

70

Offshore Cable

Black

Technical Information
VFD Cable

Earthing & Bonding wire

Instrumentation &
Communication Cable

LV Power & Lighting Cable

HV Power Cable

NEK-606 (2004), IEC 60092-350, 353, 354, 376

Type approval certificates

Offshore Cable

71