LABORATORY ACTIVITY
PHYSICAL DESCRIPTION OF UB LABORATORY BOILER
SUBMITTED BY:
QUINTO, CHRISTIAN JOSEPH F.
BSME 5 SECTION 1
SUBMITTED TO:
JOSE R. FRANCISCO, PME
OCTOBER 3, 2015
1. TYPES OF BOILER
Fire Tube Boiler
Fire Tube Boiler is a steam boiler in which gaseous product of combustion
pass through tubes surrounded by boiler water. The heat of the gases is
transferred through the walls of the tubes by thermal conduction, heating the
water and creating steam.
In fire tube boilers, the fuel is burnt inside a furnace. The hot gases
produced in the furnace then passes through the fire tubes. The fire tubes are
immersed in water inside the main vessel of the boiler. As the hot gases are
passed through these tubes, the heat energy of the gases is transferred to the
water that surrounds them. As a result, steam is generated in the water. This
steam is then taken out from the steam outlet.
As the steam and water is stored in the same vessel, it is difficult to
produce very high pressure. General maximum capacity of fire tube boilers are
17.5 kg/cm2 and with a capacity of 9 metric ton of steam per hour.
Water Tube Boilers
Water Tube Boilers are a type of boiler in which water circulates in tubes
heated externally by fire. Fuel is burned inside the furnace, creating hot gas
which heats water in the steam-generating tubes. This is just the opposite of
fire tube boilers.
It consists of mainly two drums, one is upper drum called steam drum and
the other is lower drum called mud drum. These upper drum and lower drum
are connected with two tubes namely down-comer and riser tubes. Water in
the lower drum and in the riser connected to it is heated and steam is produced
in them which come to the upper drums. In the upper drum, the steam is
separated from water and stored above the water surface. The colder water is
fed from feed water inlet at upper drum and as this water is heavier than the
hotter water of lower drum and that in the riser, the colder water push the
hotter water upwards through the riser. So there is one convectional flow of
water in the boiler system.
*The UB Boiler is a Fire Tube Boiler since hot gases from fire pass through
the tubes in which it is surrounded by water so as to generate steam.
Pressure Switch
A pressure switch is a form of
switch that closes an electrical
contact when a certain set pressure
has been reached on its input. The
switch may be designed to make
contact either on pressure rise or on
pressure fall.
Pressure Gauge
Pressure gauge, instrument
for measuring the condition of a fluid
(liquid or gas) that is specified by the
force that the fluid would exert, when
at rest, and on a unit area.
Water Level Controller
A water level controller is an
automatic device used to monitor a
particular level of water and restrict it
from exceeding the limit.
Control Panel
It is an electrical device
consisting of a flat insulated surface
that contains switches and dials and
meters for controlling other electrical
devices.
Blowdown Connection
Boiler blowdown is the
removal of water from a boiler. Its
purpose is to control boiler water
parameters within prescribed limits
to minimize scale, corrosion,
carryover, and other specific
problems. Blowdown is also used to
remove suspended solids present in
the system.
Steam Separator
Steam separator has main
function to separate water and steam
and this equipment is usually located
in steam drum. Water surface in
steam drum is turbulent, so make it
easy to mix between steam and
water.
Burner
Boiler burners are the
functional component of boilers that
provide the heat input by combustion
of a fossil fuel, including natural gas,
with air or oxygen.
Saddle
The weight of the boiler is
supported on saddles, or bearers.
3. THERMAL PLANT
condenser
is
work
from
the
turbine
(electrical
output).
The main purposes of the condenser are to condense the exhaust steam from
the turbine for reuse in the cycle and to maximize turbine efficiency by maintaining
proper vacuum. As the operating pressure of the condenser is lowered (vacuum is
increased), the enthalpy drop of the expanding steam in the turbine will also increase,
and this will increase the amount of available work from the turbine (electrical output).
Cooling Tower
A cooling tower is a heat rejection device which rejects waste heat to the
atmosphere through the cooling of a water stream to a lower temperature. Cooling
towers may either use the evaporation of water to remove process heat and cool the
working fluid to near the wet-bulb air temperature or, in the case of closed circuit dry
cooling towers, rely solely on air to cool the working fluid to near the dry-bulb air
temperature.
with nuclear power plants, although they are also used to some extent in some large
chemical and other industrial plants. Although these large towers are very prominent,
the vast majority of cooling towers are much smaller, including many units installed on
or near buildings to discharge heat from air conditioning.
Turbine
A turbine (from the Latin turbo, a vortex, related to the Greek ,tyrb,
meaning "turbulence"), is a rotary mechanical device that extracts energy from
a fluid flow and converts it into useful work. A turbine is a turbo machine with at least
one moving part called a rotor assembly, which is a shaft or drum with blades attached.
Moving fluid acts on the blades so that they move and impart rotational energy to the
rotor. Early turbine examples are windmills and waterwheels.
Gas, steam, and water turbines have a casing around the blades that contains
and controls the working fluid. Credit for invention of the steam turbine is given both
to the British engineer Sir Charles Parsons(18541931), for invention of the reaction
turbine and to Swedish engineer Gustaf de Laval (18451913), for invention of
the impulse turbine. Modern steam turbines frequently employ both reaction and
impulse in the same unit, typically varying the degree of reaction and impulse from the
blade root to its periphery.
The word "turbine" was coined in 1822 by the French mining engineer Claude
Burdin from the Latin turbo, or vortex, in a memo, "Des turbines hydrauliques ou
machines rotatoires grande vitesse", which he submitted to the Acadmie royale des
sciences in Paris. Benoit Fourneyron, a former student of Claude Burdin, built the first
practical water turbine.
Electric Generator
In electricity generation, a generator is a device that converts mechanical
energy to electrical energy for use in an external circuit. The source of mechanical
energy may vary widely from a hand crank to an internal combustion engine.
Generators provide nearly all of the power for electric power grids.
Piping
Within industry, piping is a system of pipes used to convey fluids (liquids and
gases) from one location to another. The engineering discipline of piping design studies
the efficient transport of fluid.
and concrete. The in-line components, known as fittings, valves, and other devices,
typically sense and control the pressure, flow rate and temperature of the transmitted
fluid, and usually are included in the field of Piping Design (or Piping Engineering).
was
sometimes
drawing, Engineering
Drawing,
and Design but is today commonly performed by Designers who have learned to use
automated Computer Aided Drawing / Computer Aided Design (CAD) software.,
Piping also has many other industrial applications, which are crucial for moving raw and
semi-processed fluids for refining into more useful products. Some of the more exotic
materials of construction are Inconel, titanium, chrome-moly and various other
steel alloys.
4. TECHNICAL QUALIFICATIONS
Steam Rate:
90 lbs/hr
Design Pressure:
125 psi
Operating Pressure:
100 psi
Hydrotest Pressure:
150 psi
Bursting Pressure:
768 psi
Control:
Full Bank/Non-Modulating
Burner:
Pressure Type
Ignition:
Power Specification:
Fuel:
Boiler Shell:
Firetube:
Electric
220V/1PH/60Hz
Diesel
5/16 Thick, A-515 Gr 70
1 , A-192
Tube Sheet:
Central Flue:
Gasket:
Asbestos Fiber
Observe water level at the gage glass, operating pressure, and condition of flame
and general conditions. Blow down water column, in gage glass, through the gage glass
blow down valve. This action keeps the water column and piping connections clean and
free of sediment or sludge.
Test the two float-operated low water fuel cut-offs (LWC) by blowing them
down, one at a time, while boiler is firing and under pressure. This action not only
flushes out any sludge that might accumulate under the float but it also simulates a low
water condition, by tripping the mercury switch in the LWC, turning off the burner. It is
crucial that the burner turns off immediately during these tests.
Test boiler water for proper chemical levels. The chemical levels are
softener and then preheated in a deaerator. In this particular system the condensate is
not returned to the boilers.
3) Semi-Annually
Observe water level and operating pressure in steam boilers or temperature and
operating pressure in hot water heating boilers and general conditions. Fire and cycle
boiler. The burner should start smoothly without unusual noises. Visually inspect
combustion. Changes in flame shape, color and sound are among early indicators of
potential combustion-related problems. Changes may be due to changes in fuel
pressure or gas/air linkage movement. Check gas/air linkages, on power burner that
modulate, for positioning, tightness and binding. Combustion analysis is verifiable only
with a flue gas analyzer and is performed mainly on boilers with power burners.
Inspect fuel supply system and gas controls. Leak check gas controls and
Test float-operated low water fuel cut-off (LWC) by blowing it down while the
boiler is firing and under pressure. Steam boilers, unlike hot water heating boilers, have
two of these devices. This procedure not only flushes-out any sludge that might
accumulate under the float but it also simulates a low water condition, by tripping the
mercury switch in the LWC, turning off the burner.
Note: On hot water heating boilers it may be necessary to trip the float assembly
linkage manually, after blowing down the LWC, to make the mercury switch trip. This is
done because a hot water boiler is full of water and will not always trip the mercury
switch in the LWC, like a steam boiler will, when the LWC is blown down. Remove the
cover on top of the LWC to access the float assembly linkage. It is crucial that the
burner shuts off immediately after these tests.
Test safety/safety relief valve. (Try Lever Test) Manually open the valve by lifting
up on the handle while boiler is under pressure. Water or steam should flow when this
is done and should shut off completely when the handle is released. Some boilers have
two of these devices.
Note: The discharge from these valves is under pressure and is at high temperatures.
Exercise caution to avoid personnel injury or injury to others.
Observe the operation of operating control. Operating controls start, stop and
modulate some burners (if desired) in response to the systems demand, keeping steam
Test flame detection devices on boilers with flame scanners. Remove the flame
scanner with the burner firing. The burner should shut off as a flame failure condition.
Clean the flame scanner, reinstall and reset programmer. Check for proper operation
as boiler goes through a firing cycle and light off.
Check all electrical controls and circuitry. Careful inspection may disclose any of
the following items: cracked mercury tubes, separation of mercury, cracked insulators,
jumpered conditions, loose connections, poor or deteriorated wiring and foreign
matter.
tank will cause the safety relief valve, on a hot water heating boiler, to relieve every
time that it fires. This causes the introduction of makeup water, causing a dilution of
the water chemistry in a treated system. Drain expansion tank if it is of a non-bladder
type and refill to reestablish an air cushion.
Observe operation of forced draft fan motors on boilers with power burners and
On most steam boilers with power burners swing open front and rear flue doors.
Inspect tube sheets for water leakage. The narrow ligaments between tube holes are
subject to tremendous stresses and should be watched for any sign of cracking mainly
due to overheating.
Drain steam boiler and remove all hand hole and manhole covers, where
applicable, to allow a visual check of all internal accessible areas. Example: shell, tubes
and tube sheets
Carefully examine waterside surfaces using a strong light and mirror where
required. Look for evidence of scale, corrosion, blisters, or pitting, indicating adequacy
of water treatment.
Use a high-pressure hose to wash sediment out of the bottom and other
Remove heads from the bodies of the float-operated low water fuel cut-offs
(LWC). The float-assembly and mercury switches are located on these heads..
On steam boilers remove pigtail loops from between boiler and pressure control
Check the fireside of furnace and fire tubes for any evidence of soot formation or
Check flue door gaskets and other gaskets to make sure that they are in good
condition and that they are properly secured. Replace if necessary. An ineffective seal
may allow flue gases to escape into the boiler room and result in burned gaskets and
warped flue doors.
After the fireside and waterside surfaces have been inspected and work
completed, close flue doors and re-install handhold and man hold covers if applicable.
Hook up all associated piping and refill boiler. Fire-up boiler and check for air, gas and
water leaks.