Você está na página 1de 302

ZXSDR UniRAN FDD-LTE Base St

Ground Parameter Referenc

LTE Base Station


er Reference

Version: V3.10.20P02(eNB)
V12.12.42(EMS)
Issued Date: 8th May, 2013

Revision Records
Manual Verson

Product Version

Author

R1.6

V3.10.20P02

Li Shunbin, Zhai Yanbo

R1.5

V3.10.20P01

Li Shunbin, Zhai Yanbo

R1.4

V3.10.10P20

Li Shunbin, Zhai Yanbo

R1.3

V3.10.10P01

Li Shunbin, Zhai Yanbo

R1.2

V3.10.10B04

Li Shunbin, Zhai Yanbo

R1.1

V3.10.01P02

Li Shunbin, Zhai Yanbo

R1.0

V3.10.01P01

Li Shunbin, Zhai Yanbo

Modified Parameters
Table Name

Parameter Name

Short Name

Access Control Rule Object

Access control rule number

aclNo

Antenna Attribute Object

Antenna model

antModel

Antenna Entity Object

Altitude

altitude

Antenna Entity Object

Antenna orientation

antAngle

Antenna Entity Object

Horizontal beam width

horizBeamwidth

Antenna Entity Object

Latitude

latitude

Antenna Entity Object

Longitude

longitude

Antenna Entity Object

Maximum azimuth

maxAzimuthV

Antenna Entity Object

Maximum pitch angle

retMaxTiltV

Antenna Entity Object

Mechanical offset

mechnicalOffset

Antenna Entity Object

Minimum azimuth

minAzimuthV

Antenna Entity Object

Minimum pitch angle

retMinTiltV

Antenna Entity Object

RET pitch angle

retTiltV

Antenna Entity Object

Vertical beam width

vertBeamwidth

Bandwidth QOS Queue

DSCP

dscp

Bandwidth QOS Queue

Qos queue No

qosNo

Bandwidth Resource Group

Bandwidth resource group


number

groupNo

Bidirectional Forwarding
Detection

Minimum interval of receiving requiredMinRxInterval


packets

Bidirectional Forwarding
Detection

Minimum interval of
transmitting packets

desiredMinTxInterval

BTS Cascade

ATM flow attribute


configuration

trafficProfile

BTS Cascade

Base station cascading


number

btsCascadeNo

Clock Device

Fixed delay compensation

delayCompensation

DHCP Relay Object

DHCP Relay No.

dhcpRelayNo

DHCP Relay Object

DHCP server address

dhcpServerIp

Dry Contact Device

Dry contact alarm name

almNo

Ethernet Fault Detection


Configuration

Information of event type

eventInfo

IP Layer Configuration

Domain

ipField

IP Layer Configuration

Gateway IP

gatewayIp

IPSec Security Policy


Database Object

IPSec security policy


configuration

spConfig

IPSec Security Policy


Database Object

IPSec security policy group


No.

spGroupNo

Maintenance Association

MA name

maName

Maintenance Domain

MD name

mdName

Managed Network Element

Latitude

latitude

Managed Network Element

Longitude

longitude

Optical Port Device

Protocol type of optical


module

protocolType

OSPF Area

Area sequence number

OspfAreaId

OSPF Instance

Router ID

routerId

PA

Dual-mode working mode

dualMode

PPP Link

Sequence format of MP
header

mpCode

RF Cable

Downlink attenuation

dlAttenuation

RF Cable

Uplink attenuation

ulAttenuation

RF Extend Cable

Downlink attenuation

dlAttenuation

RF Extend Cable

Uplink attenuation

ulAttenuation

SaalUni

AAL5 flow attribute


configuration

saalUniTrafficProfile

SCTP

Remote address

remoteAddr

Service and DSCP mapping

LTE FDD service and DSCP


mapping

fddServiceDscpMap

TCP

Remote Address

remoteAddr

AISG Device

Device type

devType

Antenna Entity Object

Diversity type

typeDiversity

Antenna Entity Object

Latitude type

latitudeSign

Antenna Entity Object

RET device type

retDeviceType

Antenna Entity Object

Space diversity

spaceDiversity

Bandwidth Resource Group

Maximum bandwidth of
egress

egressMBR

Bandwidth Resource Group

Used PPP link

refPppLink

BTS Cascade

BTS cascade number

btsCascadeNo

BTS Cascade

BTS cascade type

cascadeType

Certificate Management
Protocol Configuration

CA server path

caServerPath

Certificate Management
Protocol Configuration

Domain name of base station certificateName


certificate

Certificate Management
Protocol Configuration

Extended option of base


station certificate

certificateExtension

Certificate Revocation List


Configuration

Default CDP

defaultCdp

Dry Contact Device

Dry contact alarm name

almNo

Dry Contact Device

Is customized dry contact


alarm

isSelfDefineAlm

Environment Monitoring
Device

Threshold type

thresType

Ethernet Port Configuration

Working mode

operatingMode

Ethernet Switching Device

Enable port or not

isEnable

Ethernet Switching Device

Ingress rate limitation mode

ingressRateLimitMode

Ethernet Switching Device

Port working mode

portMode

IKE Policy Object

Password

passWord

IKE Policy Object

User name

userName

IKE Policy Object

XAUTH function enabled

enableXauth

IP Clock Parameters

Enable link setup by


negotiation

enableNegotiation

IP Clock Parameters

IP clock transmission mode

transType

IP Clock Parameters

IPv6 multicast type

ipv6MultiCastType

IP Layer Configuration

X2 self-setup enabled

x2SelfSetup

IPSec Global Configuration


Object

ID type

Negotiation entity idType

IPSec Security Policy


Configuration

IPSec rule action

ruleAction

OMC Channel

Interface type of operation


and maintenance

itfUniBtsType

Optical Port Device

RU board or not

isRU

OSPF Instance

Compatible with RFC1583


rule or not

enableRfc1583

PA

Board standard

radioMode

Physical Layer Port

Physical layer port number

phyLayerPortNo

Power Device Set

Power-down control
supported

enablePowerDownCtrl

Power Saving Parameter

End time of RRU channel


power saving

rruPSEndTime

Power Saving Parameter

PA static voltage adjustment


switch

paPSSwitch

Power Saving Parameter

RSSI report period

rssiReportPeriod

Power Saving Parameter

Start time of RRU channel


power saving

rruPSStartTime

PPP Link

Support IP compression or
not

ipCompress

PPP Link

Used for CDMA or not

isCDMA

PPP Link

Used for FE cascading or not isUsedToFECascade

SCTP

Primary path number

primaryPathNo

STM-1 configuration
parameter

Encoding mode

codeType

System Parameter

Enable bypass or not

enableBypass

System Parameter

Enable SLA or not

enableSla

Time Device Set

SNTP standby server IP


address

ntpServerStdIpAddr

Dry Contact Device

Dry contact alarm name

almNo

Certificate Management
Protocol Configuration

CA server type

caServerType

Ethernet Port Configuration

Transmitting bandwidth

egressPeakBitRate

Ethernet Switching Device

Link mode

operatingMode

Clock Device

Clock reference source


category

clockCategory

Clock Device

Clock reference source type

clockType

Ethernet configuration
parameter

Transmitting bandwidth

egressPeakBitRate

Ethernet configuration
parameter

Working mode

operatingMode

Physical Layer Port

Transmission medium

mediumType

Power Saving Parameter

RSSI report period

rssiReportPeriod

Static Routing Configuration

Destination IP address

ipAddress

Static Routing Configuration

Next hop IP address

nextHopIpAddr

UDP

MO Description

description

Access Control Rule Object

Access control rule number

aclNo

Access Control Rule Object

Access control rule object ID

AccessControlListId

Antenna Service

Antenna calibration period

calibrationPeriod

ATM Layer Link

Frame length

frameLen

BTS Cascade

BTS cascade number

btsCascadeNo

Certificate Management
Protocol Configuration

CA server path

caServerPath

Clock Device

Clock reference source


category

clockCategory

Clock Device

Clock reference source type

clockType

Clock Device

Input baud rate

inputBardRate

Clock Device

Receiver Operating Mode

receiverOperatingMode

Dry Contact Device

Dry contact alarm name

almNo

Environment Monitoring
Device

Threshold Type

thresType

Ethernet configuration
parameter

Transmitting bandwidth

egressPeakBitRate

Ethernet Link Layer

LACP aggregation group

refLacpGroup

Ethernet Link Layer

MTU

mtu

Ethernet Link Layer

VLAN ID

vlanMembership

Ethernet Switching Device

Ingress rate limitation mode

ingressRateLimitMode

IKE Policy Object

Used IPSec Global


Configuration Object

refIPSecGLConfig

IP Layer Configuration

1588 link selecting mode

linkSelectMode

IP Layer Configuration

IP address

ipAddr

IPSec Proposal Object

ESP authentication algorithm espAuthAlgorithm

KPI Measurement

KPI measurement number

ipKpiNo

Physical Layer Port

Ethernet Configuration
parameter

ethernetConfig

Physical Layer Port

Transmission medium

mediumType

Power Outlet Set

Switch status

switchStatus

Power Saving Parameter

RSSI report period

rssiReportPeriod

PowerOutlet

Under current alarm threshold lowerLimitPercent


percent

PowerOutlet

Working current value

currentValue

RF Device Set

Diversity receiving mode

diversityMode

Static Routing Configuration

Static routing number

staticRouteNo

System Parameter

Base station reset time of


self-recovery

selfProtectTime

System Parameter

Enable SLA or not

enableSla

UDP

MO Description

description

Antenna Attribute Object

Antenna Gain

antGain

Antenna Attribute Object

Antenna Gap

antGap

Ethernet Switching Device


Set

Enable Ethernet multi-path


transmission

enableFEMultiPath

IP Layer Configuration

Domain

ipField

Deleted Parameters
Table Name

Parameter Name

Short Name

Operator

CE percent corresponding to
operator (%)

cePercent

Power Saving Parameter

End time of power amplifier


power saving

paPSEndTime

Power Saving Parameter

Start time of power amplifier


power saving

paPSStartTime

Power Saving Parameter

RRU power saving switch

rruPSSwitch

Clock Device

Support Announce message


or not

supportAnnounce

1588 clock global parameter

1588 clock device type

clockType

1588 clock global parameter

1588 link selection mode

linkSelectMode

1588 clock global parameter

Packet Deliver Way

deliverPacketWay

1588 clock global parameter

Support CDMA Pico or Not

isSupportCdmaPico

1PPS+TOD Parameter
Configuration

Input Baud Rate

inputBardRate

1PPS+TOD Parameter
Configuration

Length of Cascade cable

cascadeCableLength

Clock Device

GNSS clock parameters

gnssClockData

Clock Device

1PPS+TOD parameter
configuration

tod1PpsData

Clock Device Set

1588 clock global parameter

clock1588Data

GNSS Clock Parameter

GNSS Cable Length

cableLength

GNSS Clock Parameter

Height of Receiver Antenna

altitude

GNSS Clock Parameter

Latitude of Receiver Antenna latitude

GNSS Clock Parameter

Length of RGPS Cascade


cable

rgpsCableLength

GNSS Clock Parameter

Longitude of Receiver
Antenna

longitude

GNSS Clock Parameter

Minimum Number of Search


Star

minStarNum

GNSS Clock Parameter

Receiver Operating Mode

1588 clock global parameter

Support CDMA Pico or not isSupportCdmaPico

Bandwidth Resource

Whether used for CDMA or


Not

isCDMA

Clock Device

GNSS receiver hardware


type
GNSS receiver working
type

receiverHardwareType

Clock Device

RGPS cable length

rgpsCableLength

IKE Policy Object

Authentication method in IKE authenticationMethod


negotiation

IKE Policy Object

passWord

Password

IKE Policy Object

refIPSecGLConfig

IPSec global settings

IKE Policy Object

userName

User name

IKE Policy Object

XAUTH function enabled

enableXauth

IPSec Configuration Object

Used IKE policy

refIKEPolicy

IPSec Global Configuration


Object

IKE retransmission interval

ikeRetransInterval

IPSec Global Configuration


Object

IKE retransmission times

ikeRetransCount

IPSec Global Configuration


Object

Negotiation entity ID type

idType

Physical Layer Port

STM-1 Configuration
parameter

stm1Config

PPP Link

Used for CDMA or not

isCDMA

Service and DSCP mapping

GSM service DSCP mapping gsmServiceDscpMap

Service and DSCP mapping

Link used by slave RNC or


not

enableSlaveFlag

Service and DSCP mapping

TD-SCDMA service and


DSCP mapping

tdsServiceDscpMap

Service and DSCP mapping

UMTS service and DSCP


mapping

umtsServiceDscpMap

Transmission Network

ATM address

atmAddr

Clock Device

receiverOperatingMode

receiverType

New Parameters
Table Name

Parameter Name

Short Name

Optical Port Device

Is RU Board

isRU

Bandwidth Resource

Whether used for CDMA or


Not

isCDMA

OMC Channel

IPOA address

ipoaAddr

Device Group

Minimum number of search


stars

minStarNum

RF Device Set

Antenna polarization mode

antPolarizationMode

BTS Cascade

LACP aggregation uplink port ref1LacpGroup

BTS Cascade

LACP aggregation downlink


port

ref2LacpGroup

Certificate Management
Protocol Configuration

Type of CA server

caServerType

Certificate Management
Protocol Configuration

Domain name of base station certificateIssuerName


certificate's issuer

KPI Measurement

KPI measurement number

ipKpiNo

Physical Layer Port

Transmission medium

mediumType

Clock Device

Receiver antenna altitude

altitude

Clock Device

GNSS cable length

cableLength

Clock Device

Cascade cable length

cascadeCableLength

Clock Device

Input baud rate

inputBardRate

Clock Device

Receiver antenna altitude

latitude

Clock Device

Receiver antenna longitude

longitude

Clock Device

Minimum number of search


stars

minStarNum

Clock Device

GNSS receiver hardware type receiverHardwareType

Clock Device

Receiver operating mode

receiverOperatingMode

Clock Device

GNSS receiver working type

receiverType

Clock Device

RGPS cable length

rgpsCableLength

1588 clock global parameter

Object ID of 1588 clock global


Global1588ConfigId
parameters

1588 clock global parameter

MO description

description

1588 clock global parameter

1588 clock device type

clockType

1588 clock global parameter

1588 line selecting mode

linkSelectMode

1588 clock global parameter

Support CDMA Pico or not

isSupportCdmaPico

1588 clock global parameter

Message transmission path

deliverPacketWay

Clock Device Set

Clock cascading output type

clockCascadeOutputType

Clock Device Set

1PPS+TOD backup between bbuMutualBackup


BBU

Baseband Device

Unit number

port

Device Group

Minimum number of search


stars

minStarNum

Device Group

Physical board name

physicalBrdType

Device Group

RRU GNSS cable length

rruGnssCableLength

External device

Device type

powerType

IP Clock Parameters

Used bandwidth resource

refBandwidthResource

IP Layer Configuration

Prefix length

prefixLength

IP Layer Configuration

X2 self-setup configuration

x2SelfSetupConfig

IPSec Configuration Object

Authentication method in IKE authenticationMethod


negotiation

IPSec Configuration Object

IKE version

ikeVersion

IPSec Configuration Object

Negotiation entity ID type

idType

IPSec Configuration Object

Used IPSec Global


Configuration Object

refIPSecGLConfig

IPSec Configuration Object

Used XAUTH configuration

refXauthConfig

OMC Channel

Base station inner IP

innerIp

OMC Channel

OMC gateway IP

gatewayIp

Optical Port Device

Radio standard

radioMode

Physical Layer Port

Backup ethernet port ID

bakeupPortID

Physical Layer Port

Ethernet port priority

portPriority

Physical Layer Port

Working mode of backup


Ethernet port

bakeupWorkMode

PPP Link

Keep Alive Time

keepAliveTime

SCTP

Heartbeat interval

hbInterval

SCTP

Maximum data
retransmission interval

maxRTO

SCTP

Maximum retransmission
times for establishing link

maxInitRetran

SCTP

Maximum retransmission
times of association

maxAssoRetran

SCTP

Maximum retransmission
times of path

maxPathRetran

SCTP

Minimum data retransmission minRTO


interval

SCTP

Radio standard

radioMode

SON Function Switch Object

Configuration for data


rollback switch

configFallback

System Parameter

Forbid FTP or not

System Parameter

Forbid TELNET or not

forbidFtp
forbidTelnet

Antenna Entity Object

Base elevation

baseElevation

Deleted Tables
Table Name

Short Name

1588 clock global parameter

StructClock1588Data

GNSS Clock Parameter

StructGnssClockData

1PPS+TOD Parameter
Configuration

StructTod1PpsData

Baseband Device Set

BpDeviceSet

Channelized STM-1

ChannelizedStm1

Mapping relation from GSM


service type to DSCP at IP
layer

StructGsmServiceDscp

Mapping relation from UMTS


service type to DSCP at IP
layer

StructUmtsServiceDscp

Mapping relation from CDMA


service type to DSCP at IP
StructCdmaServiceDscp
layer
TCP

Tcp

New Tables
Table Name

Short Name

1588 clock global parameter

Global1588Config

XAUTH Configuration Object

XauthConfig

Issued Date

Details of Revision Changes

8/May/13

1. There are 4 parameters modified as shown in Modified


Parameters below.
2. There are 1 parameter newly added as shown in New
Parameters below.

25/Mar/13

1. There are 33 parameters modified as shown in Modified


Parameters below.
2. There are 21 parameters deleted as shown in Deleted
Parameters below.
3. There are 30 parameters newly added as shown in New
Parameters below.
4. There are 6 tables deleted as shown in Deleted Tables below.
5. There are 1 table newly added as shown in New Tables below

15/Jan/13

1. There are 9 parameters modified as shown in Modified


Parameters below.
2. There are 2 parameters newly added as shown in New
Parameters below.

12/Nov/12

1. There are 4 parameters modified as shown in Modified


Parameters below.
2. There are 16 parameters deleted as shown in Deleted
Parameters below.
3. There are 17 parameters newly added as shown in New
Parameters below.
4. There are 1 table newly added as shown in New Tables below.
5. There are 3 tables deleted as shown in Deleted Tables below.

15/Oct/12

1. There are 47 parameters modified as shown in Modified


Parameters below.
2. There are 5 parameters deleted as shown in Deleted
Parameters below.
3. There are 8 parameters newly added as shown in New
Parameters below.

9/Aug/12

1. There are 47 parameters modified as shown in Modified


Parameters below.
2. There are 3 parameters newly added as shown in New
Parameters below.

26/Jul/12

First edition

Revised Date
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12

9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12
9-Aug-12

9-Aug-12
9-Aug-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12

15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
15-Jan-13
15-Jan-13
15-Jan-13
15-Jan-13
15-Jan-13
15-Jan-13
15-Jan-13
15-Jan-13
15-Jan-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13

25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
8-May-13
8-May-13
8-May-13
8-May-13

Revised Date
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12

12-Nov-12
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13

Revised Date
9-Aug-12
9-Aug-12
9-Aug-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
15-Oct-12
12-Nov-12
12-Nov-12
12-Nov-12

12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
12-Nov-12
15-Jan-13
15-Jan-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13
25-Mar-13

25-Mar-13
25-Mar-13
25-Mar-13
8-May-13

Revised Date
12-Nov-12
12-Nov-12
12-Nov-12
25-Mar-13
25-Mar-13
25-Mar-13

25-Mar-13

25-Mar-13
25-Mar-13

Revised Date
12-Nov-12
25-Mar-13

Tabel Name

Short Name

Managed NE

ManagedElement

Equipment

Equipment

Cabinet

Cabinet

Sub-rack

SubRack

Device Group

SdrDeviceGroup

Baseband Device

BpDevice

Clock Device Set

ClockDeviceSet

Clock Device

ClockDevice

Time Device Set

TimeDeviceSet

Time Device

TimeDevice

RF Device Set

RfDeviceSet

RF Port Object

RfDevice

PA

Pa

Tx Device

TxChannel

Rx Device

RxChannel

AISG Device

AisgDevice

Optical Port Device Set

FiberDeviceSet

Optical Port Device

FiberDevice

GigaBitEthernet

GeDevice

E1

E1Device

T1

T1Device

Ethernet Switching Device Set

EthernetSwitchDeviceSet

Ethernet Switching Device

EthernetSwitchDevice

Power Device Set

PmDeviceSet

Power Device

PmDevice

Dry Contact Device

DryContactDevice

Environment Monitoring Device EnvMonDeviceSet


Set
Environment Monitoring Device EnvMonDevice
Fan Device

FanDevice

Power Outlet Set

PowerOutletDeviceSet

Power Outlet

PowerOutletDevice

BTS Auxiliary Peripheral Device AuxUnit

External device

EPm

TMA Device

Tma

Antenna Attribute Object

AntProfile

Antenna Entity Object

AntEntity

Ir Antenna Group Object

IrAntGroup

RF Cable

RfCable

RF Extend Cable

RfExtendCable

Fiber Cable

FiberCable

Transmission Network

TransportNetwork

Physical Layer Port

PhyLayerPort

ATM Layer Link

AtmLayerLink

AAL2

Aal2

SaalUni

SaalUni

ALCAP

Alcap

BTS Cascade

BtsCascade

HDLC Channel

Hdlc

PPP Link

PppLink

LACP aggregation port

LacpPort

LACP aggregation group

LacpGroup

Ethernet Link Layer

EthernetLink

Ethernet Fault Detection


Configuration

EthernetOam

DHCP Relay Object

DhcpRelay

Bandwidth Resource Group

BandwidthResourceGroup

Bandwidth Resource

BandwidthResource

Bandwidth QOS Queue

BandwidthQos

IP Layer Configuration

IpLayerConfig

DSCP to COS mapping

DscpCosMap

Service and DSCP mapping

ServiceMap

Static Routing Configuration StaticRoute


Routing Detection Object

RouteDetect

IKE Policy Object

IKEPolicy

IPSec Proposal Object

IPSecTransformSet

IPSec Security Policy Database IPSecSpd


Object
XAUTH Configuration Object

XauthConfig

IPSec Global Configuration


Object

IPSecGLConfig

IPSec Configuration Object

IPSecConfig

Access Control Rule Object

AccessControlList

Certificate Revocation List Configuration


CrlConfig

Certificate Management
Protocol Configuration

CmpConfig

SCTP

Sctp

Maintenance Domain

EthernetCfmMd

Maintenance Association

EthernetCfmMa

Maintenance Point

EthernetCfmMp

UDP

Udp

Bidirectional Forwarding
Detection

Bfd

1588 clock global parameter

Global1588Config

IP Clock Parameters

IpClockProfile

KPI Measurement

IpKpi

OMC Channel

ItfUniBts

Operator

Operator

PLMN

Plmn

System Parameter

SystemFuctions

Power Saving Parameter

PowerSaving

Antenna Service

AntService

SON Function Switch Object

SonSwitch

OSPF Instance

OspfInstance

OSPF Area

OspfArea

OSPF stub settings

OspfStub

OSPF Interface

OspfInterface

DOT1X

Dot1x

Configuration of ATM
Throughput Poroperty

StructAtmTrafficProfile

Configuration of AAL5
Throughput Poroperty

StructAal5TrafficProfile

Product Information

StructProductData

Local MEP Parameter

StructLocalMEPData

Remote MEP Parameter

StructRemoteMEPData

BFD Authority Parameter

StructBfdAuthority

Information of event type

StructOamEventInfo

IPSec Security Policy


Configuration

StructSp

Configuration for hardware


auto-discovery

StructHwSelfDetecting

Configuration for site autoopening

StructSiteSelfOpening

Configuration for Auto-setup


Transmission Link

StructTransportSelfSetup

Mapping relation from LTE


StructLteServiceDscp
service type to DSCP at IP layer StructLteTddServiceDscp
Ethernet configuration
parameter

StructEthernetConfig

Configuration Recovery

StructConfigRecover

Description
Represents the SDR base station in the wireless network, or the network element.
It is the root of all MO nodes. It provides detailed services and management
functions. See 3GPP TS32.622.
Represents physical of the entity network element. It is the root node of all physical
device resource. Physical device resource includes the cabinet, shelf, board, RU,
antenna, and tower amplifier.
Cabinet object is an abstract of cabinets used in a base station.
Sub-rack is the shelf. One rack can contain one or more shelves.
Device group object, corresponding to the function set of the board.
Indicates the baseband processing unit on the base band board. The object is
used when the baseband resource are allocated for the local cell.
Indicates the set of reference clock source.
Indicates the clock reference source.
Represents the configuration set related to time information.
Indicates parameters related to time information, such as the NTP and daylightsaving time.
Indicate the set of RU RF ports. The board with the set has RF function.
Indicate the physical entity of RU RF port.
Represents the power amplifier in the remote unit (RU).
Indicates the RF transmission entity in a remote unit (RU).
Indicates the RF receiving entity in a remote unit (RU).
The AISG device object is an abstract of the AISG control port. It is used for RET to
control the antenna tilt, and for the signal amplification of TMA. For details, see
AISG v1.1, AISG v2.0, and 3GPP TS25.460 to 3GPP TS25.463.
Indicates the set of physical ports on the Ir interface. The Boards with the set have
the IQ switching function.
Indicates the physical port on the Ir interface.
Indicates the GigabitEthernet physical port (Debug port or external port).
Indicates a physical E1 port. Currently only exists on the SA and SE boards.
Indicates a physical T1 port. Currently only exists on the SA and SE boards.
Indicates the set of physical ports for Ethernet switching devices.
Represents a physical port of the Ethernet switching equipment. Currently it exists
only on the UES boards.
Represents the set of the power modules. Boards with the set have power
functions.
Represents the power module. Currently it only exists on the PM board.
Represents a dry contact port. Currently it only exists on the SA, SE, FCE boards
and radio frequency boards.
Represents the collection of environment monitoring devices.
Represents the environment monitoring function.
Represents the fan.
Represents a collection of power outlets.
Represents a power outlet. It only exists on the TAM board currently.
It represents the root node of the peripheral equipment resource of the managed
NE, including the antenna feeder system (antenna and tower amplifier) and
embedded power supply.
Describe external device, such as embedded power and shelter.
TMA control object is used to configure complementary tower amplifier gain and
other parameters.
Represents the antenna attribute, such as gain and mode.
Represents the physical entity of the antenna.
Represents the object property of the Ir antenna group.

Indicates radio frequency (RF) feeder cable resources. It represents the


connection between the RF interface of a remote unit (RU) and the antenna/tower
mounted amplifier (TMA).
Indicate the radio frequency (RF) extended cable resources. It represents the
connection between two RU RF ports (RxOut and RxIn).
Indicates the optical fiber resources, referring to the connection between baseband
unit (BBU) and Remote Unit (RU), or between two BBUs in stack mode.
It represents the transmission resource of the network element. It is the root node
of all transmission resource. Transmission resource types include IP transmission
and ATM transmission. The transmission protocol layer includes physical layer, link
layer, IP/ATM layer, and application layer. Refer to 3GPP TS32.712.
Represents the physical layer of IP or ATM transmission protocol. The physical
layer bearer includes E1, T1, and Ethernet.
Represents It represents TC or IMA (AF-PHY-0086.000 AF-PHY-0086.001) object.
Represents the AAL2 protocol. For details, see ITU-T I.363.2 B-ISDN ATM
Adaptation Layer specification: Type 2 AAL.
It represents the AAL5 protocol.
It represents the ALCAP protocol.
It represents related configuration of upper-level base station transmission when
E1 or T1 cascading is used.
Represents the HDLC protocol (ISO/IEC 13239:2002).
Represents the PPP protocol. Data transmission is implemented through the pointto-point connection established through dialing or dedicated cable. (RFC 1661 The
Point-to-Point Protocol (PPP))
Represents the attribute of the LACP aggregation port.
Represents the attribute of the LACP aggregation group.
Represents the Ethernet link layer between the base station and the upper-level
NE.
Represents the Ethernet fault detection protocol IEEE 802.3ah. After the protocol
is enabled on two point-to-point connected devices, the link status and
performance between them can be monitored.
Describes the DHCP relay function configuration. When this function is enabled,
SDR monitors DHCP broadcasting, forwards it to the DHCP server, and forwards
the returned response to the DHCP client. For details about DHCP relay function,
see RFC3046. The function related to this MO is ZWF22-03-003 DHCP.
It is used to allocate bandwidth.
It is used to divide bandwidth.
Indicate QoS queue configured on the IP bandwidth resource.
It represents the IP-layer configuration and static route.
Indicate mapping relationship from DSCP at IP layer to COS at Ethernet link layer.
It reflects the conversion of QoS from the IP layer to the link layer.
Configure service and DSCP mapping.
It is used to configure a static routing.
Represents the route detection configuration.
IKE policy object. Refer to the protocol RFC4301 and RFC4306.
IPSec proposal object. Refer to the protocol RFC4301 and RFC4306.
IPSec security policy database object. See protocol RFC4301 and RFC4306.
XAUTH Configuration Object.
Indicate IPSec Global configuration object.
IPSec configuration object. Refer to the protocol RFC4301 and RFC4306.
Access control rule object. Refer to the protocol RFC4301 and RFC4306.
Describe that base station obtains certification revocation list through LDAP
protocol to realize the function of verification certification.

Describe the congiruation information obtained by base station via CMP protocol.
This helps users to apply for and update Certificate.
Represents the SCTP protocol (RFC 2960: Stream Control Transmission Protocol).
It provides a stable and sequential data transmission service between two end
points. It is mainly used for signaling transmission in the IP network.
Maintenance domain in the 802.1ag protocol. It provides all or part of the network
for fault and performance management. The function related to the object is
ZWF22-03-009.
Maintenance association in the 802.1ag protocol. The MAs that satisfy the
following conditions are included: MPs of a MA exist within the same management
domain; MPs of a MA have the same MA level; MPs of a MA belong to the same
point-to-point ETH connection or multi-point ETH connectivity. The function related
to the object is ZWF22-03-009.
Maintenance point in the 802.1ag protocol. MEP represents an MP end point. It
can send and terminate the OAM frame, and is used for error management and
performance monitoring. The function related to the object is ZWF22-03-009.
It represents the UDP object.
Bidirectional Forwarding Detection RFC5880 (BFD) is a protocol intended to detect
faults in the bidirectional path between two forwarding engines, including
interfaces, data link, and potential low-delay faults of the forwarding engine. The
BFD operations are independent of media, data protocols, and routing protocols.
Specify the configuration of 1588 clock global parameters.
Represents parameter configuration related to IEEE1588 clock.
Configure object needs KPI measurement.
Represents the O&M interface between NE and MNS, that is, Itf-B (OMCB
channel). The connection mode of Itf-B can be direct connection or connection by
RNC/BSC. See 3GPP TS32.101.
Represents the operator. When the NE resource is shared by multiple operators,
the MO is referred to.
Used to describe objects of Public Land Mobile Network (PLMN).
System parameter object.
Power saving parameter object.
Antenna service object.
Configure switch parameters of related functions for Self-Organizing Network
(SON).
Indicate the OSPF instance basic configuration.
Indicate the OSPF area configuration.
Specify OSPF stub settings.
Indicate the OSPF interface basic configuration.
Indicate the authentication configuration of DOT1X
Specify the configuration of ATM flow control parameters on a PVC.
Specify the configuration of AAL5 flow control parameters.
Specify product Information
Specify local MEP parameters.
Specify the remote MEP information.
Specify the authentication-related configuration of BFD control packets.
Configure the information related to error frames and error symbols.
Configure the IPSec SPD security policy.
Configure parameters for hardware auto-discovery.
Configure parameters for site auto-commissioning.

Configure transmission auto-connection parameters.


Specify the LTE service carried on IP link and the QoS priority of each service.
The Ethernet port configuration.
Configuration for rollback.

Table Name
Managed NE

Device

Cabinet

SubRack

Parameter Name

Short Name

Parameter Format

NE Type

managedElementType

string

NE ID

meId

unsigned long

NE Name

userLabel

string

NE Address

locationName

string

NE Version

swVersion

string

Non-configured Board State

userDefinedState

string

Longitude

longitude

long

Latitude

latitude

long

NE ID Planned by Operator

operatorPlannedId

string

NE ID Planned by Vendor

vendorPlannedId

string

Object ID of equipment
MO Description
Device description information

Equipment
description
userLabel

unsigned long
string
string

BBU stack mode

bbuStackMode

long

Object ID of cabinet
MO Description
Cabinet number

Cabinet
description
cabinetNo

unsigned long
string
long

Cabinet type information


Cabinet position

cabinetData
cabinetPosition

StructProductData
string

Sub-rack ID
MO Description
Sub-rack No.

SubRack
description
subRackNo

unsigned long
string
long

Device Group

Baseband Device

Clock Device Set

Sub-rack type

subRackType

long

Sub-rack description information

userLabel

string

Object ID of device group


MO Description
Board product information

SdrDeviceGroup
description
productData

unsigned long
string
StructProductData

Board Radio Mode

radioMode

sequence<long,8>

Board function mode


Physical board name

functionMode
physicalBrdType

unsigned long
unsigned long

Configure high priority or not

isHighPriority

unsigned long

RRU GNSS cable length

rruGnssCableLength

long

Minimum number of search stars

minStarNum

long

Object ID of baseband device

BpDevice

unsigned long

MO Description
Unit number

description
port

string
long

Object ID of clock device set

ClockDeviceSet

unsigned long

MO Description
Clock synchronization mode

description
clockSyncMode

string
long

Clock Device

Clock source switching strategy

clockSwitchPolicy

long

Clock cascading output type

clockCascadeOutputType long

1PPS+TOD backup between BBU

bbuMutualBackup

long

Object ID of clock device

ClockDevice

unsigned long

MO Description
Clock reference source category

description
clockCategory

string
long

Clock reference source type

clockType

long

Priority

clockPriority

long

Fixed delay compensation


Enable SyncE

delayCompensation
enableSyncE

long
long

Enable SSM

isSSM

long

GNSS cable length

cableLength

long

Receiver Operating Mode

receiverOperatingMode

long

Receiver antenna longitude

longitude

long

Time Device Set

Time Device

Receiver antenna latitude

latitude

long

Receiver antenna altitude

altitude

long

Minimum number of search stars

minStarNum

long

Cascade cable length

cascadeCableLength

long

Input baud rate

inputBardRate

long

Object ID of time device set

TimeDeviceSet

unsigned long

MO Description
SNTP standby server IP address

description
ntpServerStdIpAddr

string
string

Object ID of time device

TimeDevice

unsigned long

MO Description
Clock synchronization period

description
clockSynPeriod

string
long

NTP server IP address

ntpServerIpAddr

string

Time zone

timeZone

long

Daylight saving time supported

isSuppSummTime

long

Start time of daylight saving time

summTimeStart

string

End time of daylight saving time

summTimeEnd

string

SNTP enabled

useSntp

long

Daylight saving time offset

summerTimeoffset

long

Object ID of RF device set

RfDeviceSet

unsigned long

MO Description
Diversity receiving mode

description
diversityMode

string
long

Antenna polarization mode

antPolarizationMode

long

RF Port Object

Object ID of RfDevice

RfDevice

unsigned long

PA

MO Description
Port No.
Object ID of PA

description
portNo
Pa

string
long
unsigned long

MO Description
Rated power

description
power

string
long

Frequency Band ID

suppBand

sequence<long,8>

Sub-frequency band

branchBand

long

RF Device Set

Tx Device

Rx Device

Radio standard

radioMode

sequence<long,8>

Dual-mode working mode

dualMode

long

PA shutdown switch by time slot

powerOffSwitch

long

Object ID of Tx device

TxChannel

unsigned long

MO Description
Frequency Band ID

description
suppBand

string
sequence<long,8>

Tx central frequency point

txCenterFreq

sequence<long,8>

Enable balance detection between


main set and diversity

detectSwitch

long

Object ID of Rx device

RxChannel

unsigned long

MO Description

description

string

AISG Device

Optical Port Device


Set

Frequency Band ID

suppBand

sequence<long,8>

Rx central frequency point

rxCenterFreq

sequence<long,8>

Object ID of AISG device

AisgDevice

unsigned long

MO Description
Device serial number
Device type

description
uniqueId
devType

string
string
long

Vendor code

vendorCode

string

AISG version

aisgVersion

long

Sub-unit No.

multiAntNo

long

Customized descriptive filed

userLabel

string

Superior channel

fatherPort

long

Local channel

selfPort

long

Connected TMA device

refTma

LDN

Connected antenna

refAntEntity

LDN

Object ID of optical port device set

FiberDeviceSet

unsigned long

MO Description
Working mode of network switching

description
operatingMode

Uplink connection mode

connectModeWithUpRac long
k

Object ID of optical port device

FiberDevice

unsigned long

MO Description
Connected board port No.
RU board or not

description
port
isRU

string
long
long

Optical module type

opticalModuleType

long

Protocol type of optical module

protocolType

long

Radio standard

radioMode

sequence<long,8>

Object ID of GigaBitEthernet

GeDevice

unsigned long

MO Description
Port number

description
port

string
long

E1

Object ID of E1
MO Description
Port No.

E1Device
description
port

unsigned long
string
long

T1

Object ID of T1
MO Description
Port No.

T1Device
description
port

unsigned long
string
long

Ethernet Switching
Device Set

Object ID of Ethernet switching device

EthernetSwitchDeviceSet unsigned long

MO Description
Whether send SyncE clock to
cascading device

description
isSyncEEnable

string
long

PLL reference clock source

pllResouce

long

Enable link aggregation

enableTrunk

long

Link aggregation media type

trunkMediaType

long

Optical Port Device

GigaBitEthernet

string
long

Ethernet Switching
Device

Media access type on uplink interface

upLinkMediaMode

long

Enable Ethernet multi-path


transmission

enableFEMultiPath

long

Queue priority

queuePriority

sequence<long,64>

Object ID of Ethernet switching device

EthernetSwitchDevice

unsigned long

MO Description
Port No.

description
port

string
long

Enable port or not

isEnable

long

Port working type

portMode

long

Link mode

operatingMode

long

Enable ingress rate limitation

ingressRateSwitch

long

Limit of ingress rate


Enable egress rate limitation

ingressBitRate
egressRateSwitch

long
long

Limit of egress rate


VLAN group No.

egressBitRate
vlanMembership

long
sequence<long,10>

Ingress rate limitation mode

ingressRateLimitMode

long

Object ID of power device set

PmDeviceSet

unsigned long

MO Description
Power working mode

description
operatingMode

string
long

Power-down control supported

enablePowerDownCtrl

long

Power Device

Object ID of power device

PmDevice

unsigned long

Dry Contact Device

MO Description
Object ID of dry contact device

description
DryContactDevice

string
unsigned long

MO Description
Dry contact description

description
userLabel

string
string

Dry Contact No.

dryNo

long

Dry Contact Type

dryType

long

Output Dry Contact Status

outDryType

long

Output Dry Contact Name

outDryName

string

Alarm Status

almStatus

long

Is customized dry contact alarm

isSelfDefineAlm

long

Dry contact alarm name

almNo

long

EnvMonDeviceSet

unsigned long

Power Device Set

Environment
Object ID of Environment Monitoring
Monitoring Device Set Device Set

MO Description
Object ID of environment monitoring
device

description
EnvMonDevice

string
unsigned long

MO Description
RF port

description
port

string
long

Threshold Type

thresType

long

Upper limit

upperLimit

long

Lower limit

lowerLimit

long

Recovery value of upper limit alarm

upperResumeLimit

long

Recovery value of lower limit alarm

lowerResumeLimit

long

Fan Device

Fan Device Object ID

FanDevice

unsigned long

Power Outlet Set

MO Description
Fan No.
Object ID of Power Outlet Set

description
fanNo
PowerOutletDeviceSet

string
long
unsigned long

MO Description
Switch status

description
switchStatus

string
long

Voltage (0.1V)

voltage

unsigned long

Power Outlet Object ID

PowerOutletDevice

unsigned long

MO Description
Port ID

description
port

string
long

Environment
Monitoring Device

PowerOutlet

BTS Auxiliary
Peripheral Device
External device

TMA Device

Working current value

currentValue

unsigned long

Alarm detection mode

almDetectMode

long

Under current alarm threshold percent

lowerLimitPercent

long

Over Current Alarm Threshold Percent

upperLimitPercent

long

Switch status

switchStatus

long

BTS auxiliary peripheral device ID

AuxUnit

unsigned long

MO Description
Object ID of external device

description
EPm

string
unsigned long

MO Description
Data processing mode

description
dataProcessMode

string
long

Device type

powerType

long

Connected board

refSdrDeviceGroup

LDN

TMA Device Object ID

Tma

unsigned long

MO Description
TMA No.

description
tmaNo

string
long

Antenna Attribute
Object

Antenna Entity Object

TMA Type

tmaType

long

Uplink Gain

ulGain

long

Downlink Gain

dlGain

long

TMA noise coefficient

tmaNoise

long

Downlink Delay

dlDelay

long

Uplink Delay

ulDelay

long

Object ID of antenna attribute

AntProfile

unsigned long

MO Description
Antenna manufacturer
Antenna Type
Antenna Gain
Antenna Gap
Number of antenna units
Antenna model
Object ID of antenna entity

description
antFactory
antType
antGain
antGap
antUnitsNumber
antModel
AntEntity

string
long
long
long
long
long
string
unsigned long

MO Description
Antenna entity No.
Used antenna attribute
Coverage scenario

description
antEntityNo
refAntProfile
coverScenario

string
long
LDN
long

RET Device type

retDeviceType

long

Antenna orientation

antAngle

long

Ir Antenna Group
Object

RF Cable

Validity of geographical information

isGeographValid

long

Latitude type

latitudeSign

long

Latitude
Longitude
Altitude type

latitude
longitude
altitudeDirection

long
long
long

Altitude
Altitude of base
Base elevation
Description of geographical information

altitude
altitudeBase
baseElevation
location

long
long
long
string

User ID
RET pitch angle
Maximum pitch angle
Minimum pitch angle
Mechanical offset
RET group name
Maximum azimuth
Minimum azimuth
Horizontal beam width

userLabel
retTiltV
retMaxTiltV
retMinTiltV
mechnicalOffset
retGroupName
maxAzimuthV
minAzimuthV
horizBeamwidth

string
long
long
long
long
string
long
long
long

Vertical beam width

vertBeamwidth

long

Space diversity
Diversity type
Pattern label
Cell List
Object ID of Ir antenna group

spaceDiversity
typeDiversity
patternLabel
celllist
IrAntGroup

string
string
string
sequence<long,8>
unsigned long

MO Description
Ir antenna group number
Used antenna
Connected RRU board
Object ID of RF cable

description
irAntGroupNo
refAntEntity
refSdrDeviceGroup
RfCable

string
long
sequence<LDN,8>
LDN
unsigned long

MO Description
Downlink attenuation
Uplink attenuation

description
dlAttenuation
ulAttenuation

string
long
long

Downlink delay

dlDelay

long

Uplink delay

ulDelay

long

Connected antenna

refAntEntity

LDN

Connected TMA device

refTma

LDN

RF Extend Cable

Fiber Cable

Connected RF port

refRfDevice

LDN

Object ID of RF Extend Cable

RfExtendCable

unsigned long

MO Description
Downlink attenuation
Uplink attenuation

description
dlAttenuation
ulAttenuation

string
long
long

Downlink delay

dlDelay

long

Uplink delay

ulDelay

long

Connected main ru

ref1SdrDeviceGroup

LDN

Connected extend ru

ref2SdrDeviceGroup

LDN

Object ID of fiber cable

FiberCable

unsigned long

MO Description
Upper level optical port in topology
structure

description
ref1FiberDevice

string
LDN

Lower level optical port in topology


structure

ref2FiberDevice

LDN

TransportNetwork

unsigned long

MO Description

description

string

Object ID of physical layer port

PhyLayerPort

unsigned long

MO Description
Physical layer port number

description
phyLayerPortNo

string
unsigned long

Transmission medium

mediumType

long

Connection object

connectObject

long

Used E1

refE1Device

LDN

Used T1

refT1Device

LDN

Transmission Network Object ID of transmission network

Physical Layer Port

ATM Layer Link

Used Ethernet

refGeDevice

LDN

Used STM-1 port

refStm1Device

LDN

Ethernet Configuration parameter

ethernetConfig

StructEthernetConfig

Backup Ethernet port ID

bakeupPortID

long

Working mode of backup Ethernet port bakeupWorkMode

long

Ethernet port priority

portPriority

long

ATM layer link ID

AtmLayerLink

unsigned long

MO Description
ATM layer link No.
ATM layer protocol type

description
atmLayerLinkNo
protocolType

string
unsigned long
long

Enable descrambling

isScramb

long

IMA link No.

imaNo

long

Frame length

frameLen

long

Clock mode

clockMode

long

Time slot bit mapping

timeSlotBitMap

sequence<long,32>

Used physical layer port

refPhyLayerPort

sequence<LDN,32>

AAL2

SaalUni

ALCAP

Used channelized STM-1

refChannelizedStm1

sequence<LDN,32>

Object ID of AAL2

Aal2

unsigned long

MO Description
PVC No.

description
pvcNo

string
unsigned long

AAL2 link ID

pathId

unsigned long

VPI

vpi

long

VCI

vci

long

ATM flow attribute configuration

trafficProfile

StructAtmTrafficProfile

Used ATM layer link

refAtmLayerLink

LDN

Object ID of SaalUni

SaalUni

unsigned long

MO Description
PVC No.

description
pvcNo

string
unsigned long

VPI

vpi

long

VCI

vci

long

AAL5 flow attribute configuration

saalUniTrafficProfile

StructAal5TrafficProfile

Used ATM Layer Link

refAtmLayerLink

LDN

ALCAP ID

Alcap

unsigned long

MO Description

description

string

BTS Cascade

Used SaalUni link

refSaalUni

LDN

Object ID of BTS cascade

BtsCascade

unsigned long

MO Description
BTS cascade type

description
cascadeType

string
long

BTS cascade number

btsCascadeNo

long

Used E1/T1/FE inlet

ref1PhyLayerPort

LDN

Inlet time slot bit mapping

ingressTimeSlotBitMap

sequence<long,32>

Used E1/T1/FE outlet

ref2PhyLayerPort

LDN

Outlet time slot bit mapping

egressTimeSlotBitMap

sequence<long,32>

Ingress VPI

ingressVpi

long

Ingress VCI

ingressVci

long

Used ingress ATM link

ref1AtmLayerLink

LDN

Egress VPI

egressVpi

long

Egress VCI

egressVci

long

Used egress ATM link

ref2AtmLayerLink

LDN

HDLC Channel

PPP Link

ATM flow attribute configuration

trafficProfile

StructAtmTrafficProfile

Destination NodeB ID

destinationNodeBId

long

LACP aggregation uplink port

ref1LacpGroup

LDN

LACP aggregation downlink port

ref2LacpGroup

LDN

Object ID of HDLC channel

Hdlc

unsigned long

MO Description
HDLC link No.

description
hdlcNo

string
long

Time slot bit mapping

timeSlotBitMap

sequence<long,32>

Used physical layer port

refPhyLayerPort

LDN

PPP ID

PppLink

unsigned long

MO Description

description

string

PPP link No.

pppLinkNo

long

Base station IP

localIp

string

PPP encapsulation type

protocolType

long

Sequence format of MP header

mpCode

long

MP priority

mpClass

long

Keep Alive Time

keepAliveTime

long

Support IP compression or not

ipCompress

long

Used for FE cascading or not

isUsedToFECascade

long

Maximum MP slicing length

maxFragmentSize

long

Used HDLC channel

refHdlc

sequence<LDN,16>

LacpPort

unsigned long

description

string

LACP aggregation port Object ID of LACP aggregation port


MO description

LACP aggregation
group

Ethernet Link Layer

Ethernet Fault
Detection
Configuration

DHCP Relay Object

LACP aggregation port number


Working mode of aggregation port

lacpPortNo
workMode

unsigned long
unsigned long

Timeout type of aggregation port

timeOutType

unsigned long

Aggregation port priority


Used physical layer port
Object ID of LACP aggregation group

portPriority
refPhyLayerPort
LacpGroup

unsigned long
LDN
unsigned long

MO description
LACP aggregation group number
Load sharing mode

description
lacpGroupNo
aggLoadBalance

string
unsigned long
unsigned long

Aggregation group working mode

workMode

unsigned long

Used LACP port


Object ID of Ethernet link

refLacpPort
EthernetLink

sequence<LDN,2>
unsigned long

MO Description
Ethernet link No.

description
ethernetLinkNo

string
unsigned long

MTU

mtu

long

VLAN ID

vlanMembership

sequence<long,30>

Used physical layer port

refPhyLayerPort

LDN

LACP aggregation group

refLacpGroup

LDN

Object ID of Ethernet fault detection


configuration

EthernetOam

unsigned long

MO Description
EthernetOam role

description
ethernetOamRole

string
long

OAM session timeout period

ethernetOamTimeOut

long

Packet sending interval

pduTransPeriod

long

Information of event type

eventInfo

sequence<StructOamEve
ntInfo,4>

Used physical layer port

refPhyLayerPort

LDN

DHCP Relay ID

DhcpRelay

unsigned long

MO Description
DHCP Relay No.

description
dhcpRelayNo

string
unsigned long

Used IP Layer Configuration


Enable DHCP relay function

Bandwidth Resource
Group

Bandwidth Resource

Bandwidth QOS
Queue

refIpLayerConfig
enableDhcpRelay

LDN
long

DHCP server address


dhcpServerIp
string
Object ID of bandwidth resource group BandwidthResourceGrou unsigned long
p
MO Description
Bandwidth resource group number

description
groupNo

string
long

Used Ethernet link

refEthernetLink

LDN

Maximum bandwidth of egress

egressMBR

long

Object ID of bandwidth resource

BandwidthResource

unsigned long

MO description
Bandwidth resource number
Transmission bandwidth weight

description
resourceNo
weight

string
long
long

Bandwidth QOS Queue object ID

BandwidthQos

unsigned long

MO Description
Qos queue No

description
qosNo

string
long

DSCP

dscp

sequence<long,8>

IpLayerConfig

unsigned long

MO Description
IP parameter link number

description
ipNo

string
unsigned long

Used PPP link

refPppLink

LDN

Used Ethernet link

refEthernetLink

LDN

VLAN ID

vid

long

IP address

ipAddr

string

Gateway IP

gatewayIp

string

IP Layer Configuration IP Layer Configured Object ID

Network mask

networkMask

string

prefixLength

long

Domain

ipField

long

X2 self-setup enabled

x2SelfSetup

long

X2 self-setup configuration

x2SelfSetupConfig

sequence<long,5>

DSCP to COS mapping ID

DscpCosMap

long

MO description
Used IP layer configuration

description
refIpLayerConfig

string
LDN

DSCP

dscp

long

COS

cos

long

Service and DSCP mapping ID

ServiceMap

long

MO description
Used IP layer configuration
Used bandwidth resource

description
refIpLayerConfig
refBandwidthResource

string
LDN
LDN

LTE FDD service and DSCP mapping

fddServiceDscpMap

StructLteServiceDscp

LTE TDD service and DSCP mapping

tddServiceDscpMap

StructLteTddServiceDscp

Operator

refOperator

sequence<LDN,3>

Object ID of static routing


configuration
MO description
Static routing number

StaticRoute

long

description
staticRouteNo

string
long

Prefix length

DSCP to COS
mapping

Service and DSCP


mapping

Static Routing
Configuration

Routing Detection
Object

IKE Policy Object

Destination IP address

ipAddress

string

Next hop IP address

nextHopIpAddr

string

Network mask

networkMask

string

Prefix length

prefixLength

long

Routing distance

routeDistance

long

Routing priority

routePriority

long

Used Ethernet link


VLAN ID
Object ID of routing detection

refEthernetLink
vid
RouteDetect

LDN
long
unsigned long

MO Description
Routing detection object No.
Destination address
Detection mode

description
routeDetectNo
destinationIp
detectMode

string
long
string
long

Detection period
Timeout period
Maximum lost packet
Used IP Layer Configuration

detectPeriod
timeoutPeriod
maxLostPacket
refIpLayerConfig

long
long
long
LDN

Object ID of IKE policy

IKEPolicy

unsigned long

MO Description

description

string

IKE policy number

policyNo

unsigned long

IKE policy priority

ikePriority

long

IKE version

XAUTH Configuration
Object

IPSec Global
Configuration Object

IPSec Configuration
Object

long

Encryption algorithm in IKE negotiation encryptionAlgorithm

long

Hash algorithm

hashAlgorithm

long

Random function algorithm

randomFunctionAlgorith
m

long

DH group

dhGroup

long

IKE SA lifetime

ikeLife

unsigned long

IPSecTransformSet

unsigned long

MO Description

description

string

IPSec proposal number

transformSetNo

unsigned long

IPSec mode

ipsecMode

long

ESP authentication algorithm

espAuthAlgorithm

long

ESP encryption algorithm

espEncryptionAlgorithm

long

Object ID of IPSec security Policy


Database

IPSecSpd

unsigned long

MO Description

description

string

IPSec security policy group No.

spGroupNo

unsigned long

IPSec Proposal Object Object ID of IPSec proposal

IPSec Security Policy


Database Object

ikeVersion

IPSec security policy configuration spConfig


Object ID of XAUTH configuration
XauthConfig

sequence<StructSp,48>
long

MO description
User name
Password
Object ID of IPSec global configuration

description
userName
passWord
IPSecGLConfig

string
string
string
unsigned long

MO Description

description

string

NAT supported

supportNat

unsigned long

Transmission interval of NAT keep-alive keepAliveInterval


message

unsigned long

Object ID of IPSec configuration

IPSecConfig

unsigned long

MO Description

description

string

IPSec configuration number

ipsecNo

unsigned long

Access Control Rule


Object

Authentication method in IKE


negotiation

authenticationMethod

long

Negotiation entity ID type

idType

unsigned long

IKE version

ikeVersion

long

Remote IP address

remoteAddr

string

PFS value

pfs

long

IPSec policy generation method

policyGenerationLevel

long

SA byte lifetime

byteLife

unsigned long

SA lifetime

timeLife

unsigned long

Pre-shared key
DPD function switch

preShareKey
dpdSwitch

string
long

Fully Qualified Domain Name

fqdn

string

Used XAUTH configuration


Used IP Layer Configuration

refXauthConfig
refIpLayerConfig

LDN
LDN

Used IPSec proposal


Used IPSec Security Policy Database
Object

refIPSecTransformSet
refIPSecSpd

sequence<LDN,6>
LDN

Used IPSec Global Configuration


Object

refIPSecGLConfig

LDN

Access control rule object ID

AccessControlList

unsigned long

MO description

description

string

Access control rule number


Local IP address

aclNo
localAddress

unsigned long
string

Local network mask

localNetMask

string

Remote IP address

remoteAddress

string

Remote network mask

remoteNetMask

string

Local port upper limit

minLocalPort

long

Local port lower limit

maxLocalPort

long

Remote port upper limit

minRemotePort

long

Remote port lower limit

maxRemotePort

long

Filter protocol No.

ruleProtocol

long

Filtering direction

ruleDirection

long

Filtering action

ruleAction

long

Certificate Revocation Certificate revocation list configuration


List Configuration
ID

CrlConfig

unsigned long

CRL verification function enabled

enableCrl

unsigned long

TLS supported

supportTls

unsigned long

Networking type

networkType

unsigned long

ldapServerIp
defaultCdp
refIpLayerConfig
CmpConfig

string
string
LDN
unsigned long

MO Description
Transmission protocol type

description
transportProtocol

string
long

Used IP Layer Configuration


CA server type

refIpLayerConfig
caServerType

LDN
long

IP address of CA server
CA server path

caServerIp
caServerPath

string
string

LDAP server IP address


Default CDP
Used IP Layer Configuration
Certificate
Object ID of certificate management
Management Protocol protocol
Configuration

SCTP

Domain name of base station certificate certificateName

string

Domain name of base station


certificate's issuer

certificateIssuerName

string

Extended option of base station


certificate

certificateExtension

string

Transport layer port of CA server

caServerPort

long

Private key length of base station


certificate

privateKeyLength

long

Control content of certificate application controlValue


message

string

Object ID of SCTP

Sctp

unsigned long

MO Description

description

string

SCTP link No.

sctpNo

long

Local port No.

localPort

long

Used IP Layer Configuration

refIpLayerConfig

sequence<LDN,4>

Used Bandwidth Resource


Remote port No.

refBandwidthResource
remotePort

LDN
long

Maintenance Domain

Maintenance
Association

Remote address

remoteAddr

sequence<string,4>

Primary path number

primaryPathNo

long

Number of in-and-out Streams

inOutStreamNum

long

DSCP

dscp

long

Maximum retransmission times for


establishing link

maxInitRetran

long

Maximum retransmission times of path maxPathRetran

long

Maximum retransmission times of


association

maxAssoRetran

long

Minimum data retransmission interval

minRTO

long

Maximum data retransmission interval

maxRTO

long

Heartbeat interval

hbInterval

long

Radio standard

radioMode

sequence<long,8>

Object ID of MD

EthernetCfmMd

unsigned long

MO Description
MD No.
MD index ID

description
mdNo
mdIndex

string
long
long

Used physical port

refPhyLayerPort

LDN

MD level
MD name

mdLevel
mdName

long
string

Object ID of MA

EthernetCfmMa

unsigned long

MO Description
MA No.
MA index ID

description
maNo
maIndex

string
long
long

Maintenance Point

UDP

Bidirectional
Forwarding Detection

Used Ethernet link


VLAN ID
MA name

refEthernetLink
vid
maName

LDN
long
string

CCM detection duration

ccmPeriod

long

Object ID of MP

EthernetCfmMp

unsigned long

MO Description
MP No.
MP index ID

description
mpNo
mpIndex

string
long
long

MEP full network No.

mepFullNetNo

long

MEP type

mepType

long

Local MEP detailed configuration

localMEPConfig

StructLocalMEPData

Remote MEP detailed configuration

remoteMEPConfig

StructRemoteMEPData

Enable CCM detection

enableCCMDetect

long

Object ID of UDP

Udp

unsigned long

MO Description

description

string

Used IP Layer Configuration

refIpLayerConfig

LDN

Object ID of bidirectional forwarding


detection

Bfd

unsigned long

MO Description
Bidirectional forwarding detection link
No.

description
bfdNo

string
long

Remote IP address

destinationIp

string

DSCP

dscp

long

1588 clock global


parameter

Whether multi-hop detection

multiHop

long

Minimum interval of transmitting


packets

desiredMinTxInterval

unsigned long

Minimum interval of receiving packets

requiredMinRxInterval

unsigned long

Detect time multiplier

detectAccumulator

long

Used UDP bearer

refUdp

LDN

BFD authentication parameters

bfdAuthority

StructBfdAuthority

Global1588Config

unsigned long

description

string

1588 clock device type

clockType

long

1588 link selecting mode

linkSelectMode

Message transmission path

deliverPacketWay

long

Object ID of IP clock parameters

IpClockProfile

unsigned long

MO Description

description

string

Object ID of 1588 clock global


parameters
MO description

long

IP Clock Parameters

KPI Measurement

OMC Channel

Link priority
PTP network protocol

linkPriority
networkProtocol

long
long

IP clock transmission mode

transType

long

Synchronization server IP address

syncServerAddr

string

DSCP

dscp

long

PTP port mode

ptpMode

long

Enable link setup by negotiation

enableNegotiation

long

IPv6 multicast type

ipv6MultiCastType

unsigned long

Used Ethernet link

refEthernetLink

LDN

VLAN ID

vid

long

UDP used by 1588 clock

refUdp

LDN

Used bandwidth resource


Object ID of KPI measurement

refBandwidthResource
IpKpi

LDN
unsigned long

MO Description
KPI measurement number

description
ipKpiNo

string
unsigned long

Local IP address
Remote IP address
VLAN ID
DSCP
Object ID of OMC channel

localIp
remoteIp
vlanId
dscp
ItfUniBts

string
string
unsigned long
unsigned long
unsigned long

MO Description
OMC interface link No.

description
itfUniBtsNo

string
long

Interface type of operation and


maintenance

itfUniBtsType

long

Base station inner IP

innerIp

string

Operator

PLMN

System Parameter

OMC gateway IP

gatewayIp

string

OMC server IP

omcServerIp

string

OMC subnet mask

omcNetworkMask

string

DSCP

dscp

long

IPOA address

ipoaAddr

string

OMC Prefix Length

omcServerIpPrefixLenth

unsigned long

Used IP Layer Configuration

refIpLayerConfig

LDN

Used SaalUni

refSaalUni

LDN

Used Bandwidth Resource


Object ID of operator
MO Description
Operator name

refBandwidthResource
Operator
description
operatorName

LDN
unsigned long
string
string

Operator information

userLabel

string

Object ID of PLMN
MO Description
MCC

Plmn
description
mcc

unsigned long
string
string

MNC

mnc

string

Object ID of system parameter


SystemFuctions
MO Description
description
Base station reset time of self-recovery selfProtectTime

unsigned long
string
long

Enable bypass or not

enableBypass

long

Enable SLA or not

enableSla

long

Forbid FTP or not

forbidFtp

long

Power Saving
Parameter

Antenna Service

SON Function Switch


Object

Forbid TELNET or not

forbidTelnet

long

Object ID of power saving parameter

PowerSaving

unsigned long

MO Description
RRU channel power saving switch

description
rruChannelPSSwitch

string
long

Start time of RRU channel power


saving

rruPSStartTime

string

End time of RRU channel power saving rruPSEndTime

string

PA static voltage adjustment switch

paPSSwitch

long

RSSI report period

rssiReportPeriod

long

Object ID of antenna service

AntService

unsigned long

MO Description
Antenna calibration period
Antenna calibration start time
Amplitude difference threshold of
antenna calibration channel

description
calibrationPeriod
calibrationStartTime
calChnlAmpDiffThreshold

string
long
long
long

Amplitude difference threshold of


antenna calibration process

calProcAmpDiffThreshold long

Angle difference threshold of antenna


calibration process

calProcAngleDiffThreshol long
d

Object ID of SON function switch

SonSwitch

unsigned long

MO Description
description
Configuration for hardware auto-discovery
hwSelfDetecting
switch

string
StructHwSelfDetecting

Configuration for auto-commissioning siteSelfOpening


switch

StructSiteSelfOpening

Configuration for auto-setup transmission


switch
transportSelfSetup

StructTransportSelfSetup

Configuration for data rollback switch


configFallback

StructConfigRecover

Object ID of OSPF instance

OspfInstance

unsigned long

MO Description
Router ID
SPF calculation time interval
Compatible with RFC1583 rule or not

description
routerId
timerSpf
enableRfc1583

string
string
unsigned long
long

OSPF Area

Area sequence number

OspfArea

unsigned long

OSPF stub settings

MO Description
OSPF area ID
Object ID of OSPF stub settings

description
areaId
OspfStub

string
string
unsigned long

OSPF Instance

OSPF Interface

DOT1X

MO Description
Sequence number of OSPF interface

description
OspfInterface

string
unsigned long

MO Description
OSPF interface number
Cost
Interval for sending Hello
Dead time

description
interfaceNo
cost
helloInterval
deadInterval

string
unsigned long
unsigned long
unsigned long
unsigned long

Interface priority

priority

unsigned long

Used IP layer configuration

refIpLayerConfig

LDN

Object ID of DOT1X parameter

Dot1x

unsigned long

MO Description
Waiting Authentication Duration

description
authWhile

string
unsigned long

Waiting Time for Remote EAP Packet

startWhen

unsigned long

Suspend Duration

heldWhile

unsigned long

Maximum times of authentication


request

maxStartTimes

unsigned long

Authentication user name


Authentication password
Used Ethernet link

userIdentity
userPassword
refEthernetLink

string
string
LDN

VLAN ID

vid

long

Range and Step

Default Value

Unit

BS8700
BS8800 GU360
BS8800 U120
BS8800 U120A
BS8800 U240
BS8900 GU360
BS8900 U240
BS8900 Z01S18
BS8900A
BS8900B
BS8906
N/A
BS8912 U2100

BS8700

N/A

N/A

[0..128]

N/A

N/A

[0..128]

N/A

N/A

UniRan V12.3(U V4.12.10)

UniRan V12.3(U
V4.12.10)

N/A

[0..128]

Unknow state

N/A

[-180180] step 0.000001

N/A

[-9090] step 0.000001

N/A

[0..48]

N/A

N/A

[0..48]

N/A

N/A

[1..1]
Created automatically by system
[0..128]

1
N/A
N/A

N/A
N/A
N/A

Non-stack,
Master-slave frame stack

Non-stack

N/A

[1..200]
Created automatically by system
[1..200]

N/A
N/A
N/A

N/A
N/A
N/A

N/A
[0..128]

N/A
N/A

N/A
N/A

[1..5]
Created automatically by system
[1..25]

N/A
N/A
N/A

N/A
N/A
N/A

BBU-2U,
RRU,
RSU,
Cooling,
BBU-3U,
Integration

N/A

N/A

[0..128]

N/A

N/A

[1..1]
Created automatically by system
N/A

N/A
N/A
N/A

N/A
N/A
N/A

ALL,
UMTS,
GSM,
TD-SCDMA,
CDMA,
LTE FDD,
LTE TDD

N/A

N/A

N/A
S0 board,
FS3 board,
FS4 board,
FS5 board,
FS5A board,
FS5B board,
FS5C board,
FS3A board,
Invalid

0
Invalid

N/A
N/A

No,
Yes

No

N/A

[0..8000] step 1

N/A

[1..4]

N/A

[1..1]

N/A

N/A

Created automatically by system


[0..1]

N/A
0

N/A

[1..1]

N/A

N/A

Created automatically by system


Frequency synchronization,
Phase synchronization

N/A
Phase
synchronization

N/A
N/A

No switching,
Switching by priority,
Switching by status

Switching by priority N/A

Do not support cascade,


GNSS Cascading output,
1PPS+TOD channel 1 output,
1PPS+TOD channel 2 output

Do not support
cascade

N/A

Y,
N

N/A

[1..14]

N/A

N/A

Created automatically by system


GNSS clock category,
1PPS+TOD clock category,
1588 clock category,
Line clock category

N/A
GNSS clock
category

N/A
N/A

GNSS clock category:


[Inner GNSS],
1PPS+TOD clock category:
[1PPS+TOD, Cascading
GNSS,Backplane 1PPS+TOD],
Line clock category:
[BITS-2MHz clock, BITS-2Mbps clock,
Line clock-local board, SyncE clock],
1588 clock category:
[SyncE+1588 clock,1588]

GNSS clock
N/A
category: [Inner
GNSS]
1PPS+TOD clock
category:
[1PPS+TOD]
Line clock category:
[BITS-2MHz clock]
1588 clock
category:
[SyncE+1588 clock]
Network Listenning:
[Network Listenning]

[1..8]

N/A

[-1000000000..1000000000] step 1
Yes,
No

0
Yes

ns
N/A

Yes,
No

Yes

N/A

[0..8000]

(Null),
Survey In,
Fixed Mode

Survey In

N/A

[-180180]

degree

[-9090]

degree

[0..10000]

[1..4]

N/A

[0..15]

(Null),
115200,
57600,
38400,
19200,
9600,
4800,
2400

9600

N/A

[1..1]

N/A

N/A

Created automatically by system


N/A

N/A
0.0.0.0

N/A
N/A

[1..1]

N/A

N/A

Created automatically by system


[1..24]

N/A
24

N/A
N/A

N/A

0.0.0.0

N/A

GMT - 12:00,
GMT - 11:00,
GMT - 10:00,
GMT - 9:00,
GMT - 8:00,
GMT - 7:00,
GMT - 6:00,
GMT - 5:00,
GMT - 4:30,
GMT - 4:00,
GMT - 3:30,
GMT - 3:00,
GMT - 2:00,
GMT - 1:00,
GMT - 0:00,
GMT + 1:00,
GMT + 2:00,
GMT + 3:00,
GMT + 3:30,
Yes,
GMT
No + 4:00,
GMT + 4:30,
GMT + 5:00,
[0..20]
GMT + 5:30,
GMT + 5:45,
GMT + 6:00,
GMT + 6:30,
[0..20]
GMT + 7:00,
GMT + 8:00,
GMT + 9:00,
GMT + 9:30,
GMT + 10:00,
GMT + 11:00,
GMT + 12:00,
GMT + 13:00

GMT + 8: 00

N/A

No

N/A

N/A

N/A

N/A

N/A

No,
Yes

Yes

N/A

[1..42]

N/A

[1..1]

N/A

N/A

Created automatically by system


Normal diversity reception,
Cross diversity reception

N/A
Normal diversity
receiving

N/A
N/A

Linear polarization,
Circular polarization

Linear polarization

N/A

[1..40]

N/A

N/A

Created automatically by system


N/A
[1..255]

N/A
N/A
N/A

N/A
N/A
N/A

Created automatically by system


N/A

N/A
N/A

N/A
N/A

Rx(351MHz-356MHz)Tx(361MHz366MHz),
Rx(410MHz-420MHz)Tx(420MHz430MHz),
Rx(450MHz-460MHz)Tx(470MHz480MHz),
Rx(698MHz-716MHz)Tx(728MHz746MHz),
Rx(777MHz-798MHz)Tx(746MHz768MHz),
Rx(832MHz-862MHz)Tx(791MHz821MHz),
Rx(806MHz-824MHz)Tx(851MHz869MHz),
Rx(894MHz-896MHz)Tx(849MHz851MHz),
Rx(820MHz-849MHz)Tx(865MHz894MHz),
Rx(880MHz-915MHz)Tx(925MHz1, 2, 3, Invalid
960MHz),
Rx(1710MHz-1770MHz)Tx(2110MHz2170MHz),
Rx(1710MHz-1785MHz)Tx(1805MHz1880MHz),
Rx(1850MHz-1915MHz)Tx(1930MHz1995MHz),
Rx(1920MHz-1980MHz)Tx(2110MHz2170MHz),
Rx(2500MHz-2570MHz)Tx(2620MHz2690MHz),
Rx(450MHz-460MHz)Tx(460MHz470MHz),
Rx(704MHz-716MHz)Tx(734MHz746MHz),
Rx(824MHz-849MHz)Tx(869MHz894MHz),
Rx(1447.9MHz1462.9MHz)Tx(1495.9MHz1510.9MHz),
Rx(1710MHz-1755MHz)Tx(2110MHz2155MHz),
Rx(1850MHz-1910MHz)Tx(1930MHz1990MHz),
Rx(1427MHz-1525MHz)Tx(1427MHz1525MHz),
Rx(1785MHz-1805MHz)Tx(1785MHz-

Rx(351MHzN/A
356MHz)Tx(361MH
z-366MHz)

Invalid

N/A

UMTS,
GSM,
TD-SCDMA,
CDMA,
LTE FDD,
LTE TDD

N/A

N/A

4G+1U,
2G+2U,
4G+1L,
2G+1L,
4G+2U,
1C+1L,
2C+1L,
4C+1L,
TDS+TDL,
Invalid

Invalid

N/A

Close,
Open

Close

N/A

[1..255]

N/A

N/A

Created automatically by system


Rx(351MHz-356MHz)Tx(361MHz366MHz),
Rx(410MHz-420MHz)Tx(420MHz430MHz),
Rx(450MHz-460MHz)Tx(470MHz480MHz),
Rx(698MHz-716MHz)Tx(728MHz746MHz),
Rx(777MHz-798MHz)Tx(746MHz768MHz),
Rx(832MHz-862MHz)Tx(791MHz821MHz),
Rx(806MHz-824MHz)Tx(851MHz869MHz),
Rx(894MHz-896MHz)Tx(849MHz851MHz),
Rx(820MHz-849MHz)Tx(865MHz894MHz),
Rx(880MHz-915MHz)Tx(925MHzN/A
960MHz),
Rx(1710MHz-1770MHz)Tx(2110MHz2170MHz),
Rx(1710MHz-1785MHz)Tx(1805MHz1880MHz),
Yes,
Rx(1850MHz-1915MHz)Tx(1930MHzNo
1995MHz),
[1..255]
Rx(1920MHz-1980MHz)Tx(2110MHz2170MHz),
Rx(2500MHz-2570MHz)Tx(2620MHzCreated automatically by system
2690MHz),
Rx(450MHz-460MHz)Tx(460MHz470MHz),
Rx(704MHz-716MHz)Tx(734MHz746MHz),
Rx(824MHz-849MHz)Tx(869MHz894MHz),
Rx(1447.9MHz1462.9MHz)Tx(1495.9MHz1510.9MHz),
Rx(1710MHz-1755MHz)Tx(2110MHz2155MHz),
Rx(1850MHz-1910MHz)Tx(1930MHz1990MHz),
Rx(1427MHz-1525MHz)Tx(1427MHz1525MHz),
Rx(1785MHz-1805MHz)Tx(1785MHz1805MHz),
Rx(1900MHz-1920MHz)Tx(1900MHz1920MHz),

N/A
N/A
Rx(351MHzN/A
356MHz)Tx(361MH
z-366MHz)

N/A

No

N/A

N/A

N/A

N/A

N/A

Rx(351MHz-356MHz)Tx(361MHz366MHz),
Rx(410MHz-420MHz)Tx(420MHz430MHz),
Rx(450MHz-460MHz)Tx(470MHz480MHz),
Rx(698MHz-716MHz)Tx(728MHz746MHz),
Rx(777MHz-798MHz)Tx(746MHz768MHz),
Rx(832MHz-862MHz)Tx(791MHz821MHz),
Rx(806MHz-824MHz)Tx(851MHz869MHz),
Rx(894MHz-896MHz)Tx(849MHz851MHz),
Rx(820MHz-849MHz)Tx(865MHz894MHz),
Rx(880MHz-915MHz)Tx(925MHz960MHz),
N/A
Rx(1710MHz-1770MHz)Tx(2110MHz2170MHz),
Rx(1710MHz-1785MHz)Tx(1805MHz1880MHz),
[1..12]
Rx(1850MHz-1915MHz)Tx(1930MHz1995MHz),
Rx(1920MHz-1980MHz)Tx(2110MHzCreated automatically by system
2170MHz),
[1..32]
Rx(2500MHz-2570MHz)Tx(2620MHzRETC,
2690MHz),
MULTI_RET,
Rx(450MHz-460MHz)Tx(460MHzATMA,
470MHz),
NOTCH_FILTER
Rx(704MHz-716MHz)Tx(734MHzMULTI_TMA,
746MHz),
ACOM,
Rx(824MHz-849MHz)Tx(869MHzAETMA,
894MHz),
NSNRET,
Rx(1447.9MHzLGPTMA
1462.9MHz)Tx(1495.9MHz1510.9MHz),
Rx(1710MHz-1755MHz)Tx(2110MHz[0..128]
2155MHz),
Rx(1850MHz-1910MHz)Tx(1930MHz1990MHz),
1:1.1{1.1,
Rx(1427MHz-1525MHz)Tx(1427MHz2:2.0{2.0
1525MHz),
Rx(1785MHz-1805MHz)Tx(1785MHz1805MHz),
[1..4], Invalid
Rx(1900MHz-1920MHz)Tx(1900MHz1920MHz),
Rx(2010MHz-2025MHz)Tx(2010MHz[0..32]
2025MHz),
Rx(1850MHz-1910MHz)Tx(1850MHz1910MHz),
Rx(1930MHz-1990MHz)Tx(1930MHz[0..12]
1990MHz),
Rx(1910MHz-1930MHz)Tx(1910MHz[0..12]
1930MHz),
Rx(2570MHz-2620MHz)Tx(2570MHz2620MHz),
N/A
Rx(1880MHz-1920MHz)Tx(1880MHz1920MHz),
Rx(2300MHz-2400MHz)Tx(2300MHzN/A
2400MHz),
Rx(2496MHz-2690MHz)Tx(2496MHz2690MHz),
Rx(3400MHz-3600MHz)Tx(3400MHz[1..1]
3600MHz),
Rx(3500MHz-3700MHz)Tx(3500MHz3700MHz)

Rx(351MHzN/A
356MHz)Tx(361MH
z-366MHz)

N/A

N/A

N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

N/A

1.1

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Created automatically by system


Load-sharing mode

N/A
N/A
Load-sharing mode N/A

single up-link optical line,


double master&slave optical lines,
multiple load-sharing optical lines

single up-link optical N/A


line

[1..16]

N/A

N/A

Created automatically by system


[0..5]
N,
Y

N/A
0
N

N/A
N/A
N/A

2.5G,
3G,
4G,
6G,
10G

Is RU Board=N:
[2.5G],
Is RU Board=Y:
[2.5G]

N/A

Is RU Board=N:
[PHY CPRI{PHY CPRI, PHY LTE IR,
PHY OBSAI, PHY OBRI, PHY GBRS,
PHY TD-SCDMAIR],
Is RU Board=Y:
[APP ZTE, APP LTE IR, APP TDSCDMAIR, APP OBRI]

Is RU Board=N:
PHY CPRI
Is RU Board=Y:
APP ZTE

N/A

ALL
UMTS
GSM
TD-SCDMA
CDMA
LTE FDD
LTE-TDD

ALL

N/A

[1..2]

N/A

N/A

Created automatically by system


[0..1]

N/A
N/A

N/A
N/A

[1..8]
Created automatically by system
[0..7]

N/A
N/A
N/A

N/A
N/A
N/A

[1..8]
Created automatically by system
[0..7]

N/A
N/A
N/A

N/A
N/A
N/A

[1..1]

N/A

Created automatically by system


Yes,
No

N/A
No

N/A
N/A

Provided by uplink interface line,


Provided by main control board

Provided by uplink
interface line

N/A

Yes,
No

No

N/A

Electrical port,
Optical port

Electrical port

N/A

Electrical port preferred,


Optical port preferred,
Forced electrical port,
Forced optical port

Electrical port
preferred

N/A

Yes,
No

No

N/A

[0..3]

0,0,0,0,0,0,0,0,0,0,0 N/A
,0,0,0,0,0,1,1,1,1,1,
1,1,1,1,1,1,1,1,1,1,1
,2,2,2,2,2,2,2,2,3,3,
3,3,3,3,3,3,3,3,3,3,3
,3,3,3,3,3,3,3,3,3,3,
3

[1..8]

N/A

N/A

Created automatically by system


Electrical port X1 of the panel,
Electrical port X2 of the panel,
Electrical port X3 of the panel,
Electrical port UPLINK of the panel,
Optical port X4 of the panel,
Optical port UPLINK of the panel,
SGMII port CC1 of the back board,
SGMII port CC2 of the back board

N/A
N/A

N/A
N/A

Yes,
No

Yes

N/A

Cascading port,
Uplink interface

Cascading port

N/A

Electrical port X1 of the panel:[Self


adaptive, 100Mbps full-duplex],
Electrical port X2 of the panel:[Self
adaptive, 100Mbps full-duplex],
Electrical port X3 of the panel:[Self
adaptive, 100Mbps full-duplex],
Electrical port UPLINK of the panel:
[Self adaptive, 100Mbps full-duplex],
Optical port X4 of the panel:[100Mbps
full-duplex, 1000Mbps full-duplex,
1000Mbps self adaptive],
Optical port UPLINK of the panel:
[100Mbps full-duplex, 1000Mbps fullduplex, 1000Mbps self adaptive],
SGMII port CC1 of the back board:
[Self adaptive],
Yes,
SGMII port CC2 of the back board:
No
[Self adaptive]
[560..1000000]
Yes,
No

Electrical port X1 of
the panel: [Self
adaptive],
Electrical port X2 of
the panel: [Self
adaptive],
Electrical port X3 of
the panel: [Self
adaptive],
Electrical port
UPLINK of the
panel: [Self
adaptive],
Optical port X4 of
the panel:
[1000Mbps self
Yes
adaptive],
Optical port UPLINK
1000
of
the panel:
[1000Mbps
self
No
adaptive],
SGMII port CC1 of
250000
the back board:
N/A
[Self adaptive],
SGMII port CC2 of
the back board:
[Self adaptive]

N/A

[70..250000]
[1..10]

N/A
kbps
N/A
kbps
N/A

Limit and count all frames,


Limit and count broadcast/multicast
and flooding frame,
Limit and count broadcast and
multicast,
Limit and count broadcast

Limit and count


broadcast

N/A

[1..1]

N/A

N/A

Created automatically by system


Master/slave mode,
Load-sharing mode

N/A
Master/slave mode

N/A
N/A

Yes,
No

No

N/A

[1..1]

N/A

N/A

Created automatically by system


[1..32]

N/A
N/A

N/A
N/A

Created automatically by system


[0..128]

N/A
N/A

N/A
N/A

[0..3]

N/A

Input dry contact,


Output dry contact

Input dry contact

N/A

Output low level,


Output high level

N/A

N/A

[0..127]

N/A

N/A

Alarm when closed,


Alarm when open

Alarm when closed

N/A

Yes,
No

No

N/A

Not customized dry contact alarm:


[Door control alarm,
Flooding alarm,
Smog alarm,
Infrared alarm,
Air conditioner fault,
Lightning protection device alarm,
PSU alarm,
PSU fan alarm,
Main power supply has a fault alarm,
Battery alarm,
AC power-cut alarm,
Rectifier module alarm,
Thermoelectric cooler alarm,
Blocked dust proof net,
Battery pack fan failed,
Battery low-voltage alarm,
Faulty external device connected at a
dry contact,
Outdoor lightning protection box alarm,
[1..1]
Breaker alarm in indoor lightning
protection box,
Lightning protection device alarm in
indoor lightning protection box,
Over-voltage alarm of main power
input,
Main power input power-cut alarm,
Under-voltage alarm of main power
input,

Not customized dry N/A


contact alarm:
[Door control alarm]
customized dry
contact alarm:
[Self Define
Drycontact 1]

N/A

N/A

Created automatically by system


[1..32]

N/A
N/A

N/A
N/A

Created automatically by system


[0..254],
Invalid

N/A
Invalid

N/A
N/A

Board temperature,
Environment temperature,
Base Station temperature,
Level-1 VSWR threshold,
Level-2 VSWR threshold,
Humidity,
Fan speed level,
MP Voltage,
PP Voltage,
Temperature at air inlet,
Temperature at air outlet,
DC input voltage of PM board,
Temperature of cabinet,
RRU RF channel over temperature
threshold,
DC input voltage of PMAC board,
AC input voltage of PMAC board,
VSWR threshold,
Strong Interference Alarm
N/A
Threshold,
Temperature rise of low
temperature CC board,
Temperature
rise of high
N/A
temperature CC board,
Temperature rise of low
temperature PM board,
Temperature
rise of high
N/A
temperature PM board

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

[1..20]

N/A

N/A

Created automatically by system


[1..20]
[1..1]

N/A
N/A
N/A

N/A
N/A
N/A

Created automatically by system


Close,
AISG RS485,
NSBT RS485

N/A
Close

N/A
N/A

140,
220,
Invalid

Invalid

N/A

[1..10]

N/A

N/A

Created automatically by system


[0..5] step 1

N/A
0

N/A
N/A

Voltage=140:[75..400],
Voltage=220:[75..300],
Voltage=Invalid:Invalid

250

mA

currentDetect,
pulsewidthDetect

N/A

N/A

[20..80], 100

80

N/A

100, [120..180]

100

N/A

Close,
Open

Open

N/A

[1..1]

N/A

N/A

Created automatically by system


[1..201]

N/A
N/A

N/A
N/A

Created automatically by system


Transparent transmission,
parsing mode

N/A
Transparent
transmission

N/A
N/A

ZXDU58 B900
ZXDU58 B121
ZXDU68 B201
ZXDU150
ZXDU45
ZXDU75
ZXDU58 B121 (V4.5)
ZXDU68 B201 (V5.0)
ZXDU68 W301
ZXDU68 S301
ZXDU58 B121 (V2.2)/W121(V1.20)
ZXDU68 B201(V5.0R99M03)
Shelter JZ9

ZXDU58 B900

N/A

N/A

N/A

N/A

[1..1200]

N/A

N/A

Created automatically by system


[1..96]

N/A
1

N/A
N/A

TMA,
A-TMA,
A-COM,
ETMA,
A-ETMA

N/A

N/A

TMA:[70..150],
A-TMA:[44..100],
A-COM:[0..14],
ETMA:[200..320],
A-ETMA:[92..100],
Invalid

TMA: [120],
A-TMA: [48],
A-COM: [10],
ETMA: [240],
A-ETMA: [96]

N/A

[70..170],
Invalid

Invalid

N/A

[10..30]

20

N/A

[0..100]

ns

[0..100]

ns

[1..600]

N/A

N/A

Created automatically by system


[0..255]
[0..255]
[0..255]
[0..65535]
[1..8]
[1..40]
[1..576]

N/A
0
2
8
75
1
General Model
N/A

N/A
N/A
N/A
dBi
mm
N/A
N/A
N/A

Created automatically by system


[1..65535]
N/A
Indoor,
Urban,
DenseUrban,
SubUrban,
HighWay,
HighRail

N/A
1
N/A
Urban

N/A
N/A
N/A
N/A

Non RET,
Uni-antenna RET,
Uni-direction TMA,
Contijuous power antenna system,
Bi-direction TMA,
LNA,
Multi-antenna RET

Non RET

N/A

[0..359.5] step 0.5

N/A

valid,
invalid

valid

N/A

North latitude,
South latitude

North Latitude

N/A

[-9090] step 0.000001


[-180180] step 0.000001
Depth,
Height

0
0
Depth

degree
degree
N/A

[0..65535]
[0..65535]
[0..1000]
[0..64]

0
0

m
cm

N/A

N/A

[0..128]
[0..360] step 1
[0..360] step 1
[0..360] step 1
[0..360] step 1
[0..80]
[0..360] step 1
[0..360] step 1
[0..360]

N/A
0
0
0
0
0
0
0
0

N/A
degree
degree
degree
degree
N/A
degree
degree
N/A

[0..180]

N/A

[0..255]
[0..255]
[0..32]
N/A
[1..4294967295]

0
0
N/A
N/A
2

N/A
N/A
N/A
N/A
N/A

Created automatically by system


[1..8]
N/A
N/A
[1..1200]

N/A
1
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

Created automatically by system


[0..8] step 0.1
[0..8] step 0.1

N/A
0
N/A

N/A
dB
dB

[0..1000]

ns

[0..1000]

ns

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

[1..108]

N/A

N/A

Created automatically by system


[0..8] step 0.1
[0..8] step 0.1

N/A
0
N/A

N/A
dB
dB

[0..1000]

ns

[0..1000]

ns

N/A

N/A

N/A

N/A

N/A

N/A

[1..200]

N/A

N/A

Created automatically by system


N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

[1..1]

N/A

Created automatically by system

TransportNetwork=1 N/A

[1..40]

N/A

N/A

Created automatically by system


[0..17]

N/A
0

N/A
N/A

E1,
T1,
STM-1,
Ethernet,
Relay port,
LIPA port

Ethernet

RNC/BSC/CN/MME,
SDR,
Third-party

RNC/BSC/CN/MME N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Electrical port self-adaptive,


Electrical port 10Mbps FDT,
Electrical port 100Mbps FDT,
Optical port 100Mbps FDT,
Optical port 1000Mbps FDT,
Optical port 1000Mbps selfadaptive,
Optical port 10000Mbps FDT

N/A

N/A

Master port priority,


Backup port priority,
Automatic priority

N/A

N/A

[1..12]

N/A

N/A

Created automatically by system


[0..11]
IMA,
TC

N/A
0
IMA

N/A
N/A
N/A

Yes,
No

Yes

N/A

[0..3]

N/A

(Null),
32 cell,
64 cell,
128 cell,
256 cell

128 cell

N/A

ITC,
CTC

ITC

N/A

[0..1]

0,1,1,1,1,1,1,1,1,1,1 N/A
,1,1,1,1,1,1,1,1,1,1,
1,1,1,1,1,1,1,1,1,1,1

N/A

N/A

Abis port

N/A

N/A

N/A

N/A

[1..50]

N/A

N/A

Created automatically by system


[1..50] step 1

N/A
1

N/A
N/A

[1..0xFFFFFFFF]

N/A

[0..255]

N/A

[8..65535]

N/A

N/A

2048,2048,2048,20 N/A
48,2048,2048,0

N/A

N/A

N/A

[1..18]

N/A

N/A

Created automatically by system


64490, [64500..64516]

N/A
64500

N/A
N/A

[0..255]

N/A

[8..255]

N/A

N/A

128,128,128,128,12 N/A
8,128,0

N/A

N/A

N/A

[1..2]

N/A

N/A

Created automatically by system

N/A

N/A

N/A

N/A

N/A

[1..1084]

N/A

Created automatically by system


TSI,
ATM routing,
FE cascade,
LACP cascade

N/A
TSI

N/A
N/A

TSI: [0..100],
ATM Routing: [65000..65059],
FE cascade:[08]
LACP cascade:[03]

N/A

Invalid,
phyLayerPortNo=0

Invalid

N/A

[0..1]

0,1,1,1,1,1,1,1,1,1,1 N/A
,1,1,1,1,1,1,1,1,1,1,
1,1,1,1,1,1,1,1,1,1,1

Invalid,
phyLayerPortNo=0

Invalid

[0..1]

0,1,1,1,1,1,1,1,1,1,1 N/A
,1,1,1,1,1,1,1,1,1,1,
1,1,1,1,1,1,1,1,1,1,1

[0..255]

N/A

[8..65535]

N/A

N/A

N/A

N/A

[0..255]

N/A

[8..65535]

N/A

N/A

N/A

N/A

N/A

N/A

2048,2048,2048,20 N/A
48,2048,2048,0

[0..65535]

N/A

N/A

N/A

N/A

N/A

N/A

N/A

[1..17]

N/A

N/A

Created automatically by system


[0..16]

N/A
0

N/A
N/A

[0..1]

0,1,1,1,1,1,1,1,1,1,1 N/A
,1,1,1,1,1,1,1,1,1,1,
1,1,1,1,1,1,1,1,1,1,1

N/A

N/A

N/A

[1..16]

N/A

N/A

Created automatically by system

N/A

N/A

[0..15]

N/A

N/A

0.0.0.0

N/A

PPP,
ML-PPP

ML-PPP

N/A

Long sequence,
Short sequence,
Invalid

Invalid

N/A

Long sequence:[1..8],
Short sequence:[1..4],
Invalid

Invalid

N/A

[500..5000]

1000

ms

Yes,
No

No

N/A

Yes,
No

No

N/A

[64..512]

128

N/A

N/A

N/A

N/A

[1..4]

N/A

N/A

Created automatically by system

N/A

N/A

[0..3]
Active,
Passive

0
Active

N/A
N/A

Short type,
Long type

Short type

N/A

[0..65535]
N/A
[1..4]

0
N/A
N/A

N/A
N/A
N/A

Created automatically by system


[0..1]
Not supported,
Source MAC and destination MAC,
Source IP and destination IP,
TCP/UDP source port and destination
port

N/A
0
Not supported

N/A
N/A
N/A

Static mode,
Dynamic mode,
Mixed mode

Static mode

N/A

N/A
[1..5]

N/A
N/A

N/A
N/A

Created automatically by system


[0..4]

N/A
0

N/A
N/A

[256..1800]

1500

Byte

[1..4094]

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

[1..1]

N/A

N/A

Created automatically by system


Passive,
Active

N/A
Passive

N/A
N/A

[5..10]

[1..10]

10

100ms

N/A

N/A

N/A

N/A

N/A

N/A

[1..1]

N/A

N/A

Created automatically by system


[0..0]

N/A
0

N/A
N/A

N/A
Yes,
No

N/A
No

N/A
N/A

N/A
[1..24]

0.0.0.0
N/A

N/A
N/A

Created automatically by system


[0..15]

N/A
0

N/A
N/A

N/A

N/A

N/A

[0..100000]

100000

kbps

[1..24]

N/A

N/A

Created automatically by system


[1..7]
[0..100]

N/A
N/A
100

N/A
N/A
%

[1..8]

N/A

N/A

Created automatically by system


[1..6]

N/A
1

N/A
N/A

[0..63]

N/A

[1..20]

N/A

N/A

Created automatically by system


[0..19]

N/A
0

N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

[1..4094]

N/A

N/A

N/A

N/A

N/A

N/A

0.0.0.0

N/A

N/A

255.255.255.0

N/A

[1..128]

16

N/A

0, 1, 2, 3, Invalid

Invalid

N/A

No,
Yes

N/A

N/A

FDD X2 CP,

N/A

N/A

[1..1984]

N/A

N/A

Created automatically by system


N/A

N/A
N/A

N/A
N/A

[0..63] step 1

46

N/A

[0..7] step 1

N/A

[1..32]

N/A

N/A

Created automatically by system


N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

[1..100]

N/A

N/A

Created automatically by system


[0..99]

N/A
0

N/A
N/A

TDD X2 CP,
FDD X2 UP,
TDD X2 UP,
Relay SCTP

N/A

0.0.0.0

N/A

N/A

0.0.0.0

N/A

N/A

255.255.255.0

N/A

[1..128]

16

N/A

[1..254]

254

N/A

[0..7]

N/A

N/A
[1..4094]
[1..100]

N/A
N/A
N/A

N/A
N/A
N/A

Created automatically by system


[1..100]
N/A
ICMP,
ARP

N/A
1
0.0.0.0
ICMP

N/A
N/A
N/A
N/A

[5..20]
[5..20]
[3..5]
N/A

5
5
3
N/A

100ms
100ms
N/A
N/A

[1..128]

N/A

Created automatically by system

N/A

N/A

[1..128]

N/A

[0..127]

N/A

IKEV1,
IKEV2

IKEV1

N/A

DES,
3DES,
AES-128

DES

N/A

MD5,
SHA1

SHA1

N/A

MD5,
SHA1

MD5

N/A

MODP768,
MODP1024

MODP768

N/A

[1..0xffffffff]

1800

[1..40]

N/A

N/A

Created automatically by system

N/A

N/A

[1..40]

N/A

Transport,
Tunnel

Tunnel

N/A

MD5,
SHA1

MD5

N/A

ESP AES-128,
3DES

ESP AES-128

N/A

[1..48]

N/A

N/A

Created automatically by system

N/A

N/A

[1..48]

N/A

N/A
[1..48]

N/A
N/A

N/A
N/A

N/A
[0..63]
[0..63]
[1..1]

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

Created automatically by system

N/A

N/A

Yes,
No

No

N/A

[1..65535]

20

[1..48]

N/A

N/A

Created automatically by system

N/A

N/A

[1..48]

N/A

Pre-shared key authentication,


X.509 certificate authentication

X.509 certificate
authentication

N/A

Pre-shared key authentication:


[IPv4 address, FQDN]
X.509 certificate authentication:
[FQDN]

IPv4 address

N/A

IKEV1,
IKEV2

IKEV1

N/A

N/A

0.0.0.0

N/A

Disable PFS,
MODP768,
MODP1024

Disable PFS

N/A

Use,
Require,
Unique

Unique

N/A

[2560..536870912]

4608000

Kbyte

[120..86400]

56000

[0..29]
Close,
Open

N/A
Open

N/A
N/A

[0..63]

N/A

N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

[1..60]

N/A

N/A

Created automatically by system

N/A

N/A

[0..59]
N/A

1
0.0.0.0

N/A
N/A

N/A

255.255.255.0

N/A

N/A

0.0.0.0

N/A

N/A

255.255.255.0

N/A

[0..65535]

N/A

[0..65535]

65535

N/A

[0..65535]

N/A

[0..65535]

65535

N/A

ICMP,
TCP,
UDP,
SCTP,
All

All

N/A

IP transmission direction,
IP receiving direction,
IP bi-direction

IP bi-direction

N/A

Pass,
Discard

Pass

N/A

[1..1]

N/A

N/A

Yes,
No

No

N/A

Yes,
No

No

N/A

IPINIP,
Independent networking

Independent
networking

N/A

N/A
[0..255]
N/A
[1..1]

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

Created automatically by system


HTTP,
HTTPS

N/A
HTTP

N/A
N/A

N/A
EJBCA,
RCM

N/A
RCM

N/A
N/A

N/A
[1..63]

0.0.0.0
cmp

N/A
N/A

[1..255]

C=CN,O=ZTE,CN= N/A
Nodeb01

[1..255]

C=CN,O=ZTE,CN= N/A
ZTE Root CA

[0..255]

N/A

N/A

[1..65535]

80

N/A

[1024, 2048]

1024

bit

[0..36]

N/A

N/A

[1..48]

N/A

N/A

Created automatically by system

N/A

N/A

[0..47]

N/A

[0..65535]

N/A

N/A

N/A

N/A

N/A
[0..65535]

N/A
0

N/A
N/A

N/A

0.0.0.0

N/A

[0..3]

N/A

[2..6]

N/A

[0..63]

46

N/A

[1..10]

N/A

[1..32]

N/A

[1..64]

10

N/A

[100..10000]

500

ms

[100..60000]

5000

ms

[100..60000]

5000

ms

UMTS
GSM
TD-SCDMA
CDMA
LTE FDD
LTE-TDD

N/A

N/A

[1..8]

N/A

N/A

Created automatically by system


[0..7]
[1..8]

N/A
0
1

N/A
N/A
N/A

N/A

N/A

N/A

[0..7]
[1..43]

0
mdName

N/A
N/A

[1..4]

N/A

N/A

Created automatically by system


[0..31]
[1..4]

N/A
0
1

N/A
N/A
N/A

N/A
[1..4094]
[1..43]

N/A
N/A
maName

N/A
N/A
N/A

100ms,
1s,
10s,
1min,
10min

100ms

N/A

[1..32]

N/A

N/A

Created automatically by system


[0..255]
[1..32]

N/A
0
1

N/A
N/A
N/A

[1..8191]

N/A

Local MEP,
Remote MEP

Local MEP

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Yes,
No

No

N/A

[1..140]

N/A

N/A

UDP%,IpNo=
%,##UdpId,refIpLayerConfig.ipNo

N/A

N/A

N/A

N/A

N/A

[1..10]

N/A

N/A

Created automatically by system


[1..10]

N/A
1

N/A
N/A

N/A

0.0.0.0

N/A

[0..63]

46

N/A

Yes,
No

No

N/A

[100..100000] step 100

300

ms

[100..100000] step 100

300

ms

[3..255]

N/A

N/A

N/A

N/A

N/A

N/A
N/A

N/A
N/A

N/A
Ordinary clock,
Boundary clock
Switch by packet loss rate,
Switch by BMC algorithm

N/A
Ordinary clock

N/A
N/A

Switch by packet
loss rate

N/A

one-way,
two-way

two-way

[1..32] step 1

N/A

N/A

Created automatically by system

N/A

N/A

[1..1]

[1..32]
IPV4,
IPV6,
Ethernet

1
IPV4

N/A
N/A

Ethernet:[Multicast],
IPV4:[Multicast, Unicast, Hybridcast],
IPV6:[Multicast, Unicast, Hybridcast]

N/A

N/A

Ethernet:
[Multicast],
IPV4: [Unicast],
IPV6: [Unicast]
0.0.0.0

[0..63]

46

N/A

Master,
Slave

Slave

N/A

Yes,
No

IPV4: [Yes]
IPV6: [Yes]
Ethernet: [No]

N/A

Interface domain,
Link domain,
Admin domain,
Site domain,
Organization domain,
Global domain

Link domain

N/A

N/A

N/A

N/A

[1..4094]

N/A

N/A

N/A

N/A

N/A

N/A
[1..94]

N/A
N/A

N/A
N/A

Created automatically by system


[0..93]

N/A
0

N/A
N/A

N/A
N/A
[1..4094]
[0..63]
[1..8]

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

Created automatically by system


[0..7]

N/A
0

N/A
N/A

IPINIP,
IPOA,
Independent networking

Independent
networking

N/A

N/A

0.0.0.0

N/A

N/A

N/A

0.0.0.0

N/A

N/A

0.0.0.0

N/A

N/A

255.255.255.255

N/A

[0..63]

46

N/A

N/A

0.0.0.0

N/A

[1..128]

16

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
[1..8]
Created automatically by system
[1..127]

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

[0..128]

N/A

N/A

[1..1]
Created automatically by system
[3..3]

N/A
N/A
N/A

N/A
N/A
N/A

[2..3]

N/A

N/A

[1..1]
Created automatically by system
[15..65535]

N/A
N/A
120

N/A
N/A
min

Yes,
No

No

N/A

Yes,
No

No

N/A

Yes,
No

No

N/A

Yes,
No

No

N/A

[1..1]

N/A

N/A

Created automatically by system


Close,
Open

N/A
Close

N/A
N/A

[0..20]

0:00

N/A

[0..20]

0:00

N/A

Close,
Open

Close

N/A

No reporting,
5,
10,
20,
30,
60

10

[1..1]

N/A

N/A

Created automatically by system


[30..1092]
[0..1440]
[10..80]

N/A
60
0
50

N/A
min
N/A
0.1dB

[5..60]

50

0.1dB

[0..360]

10

degree

[1..1]

N/A

N/A

Created automatically by system


N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

[1..1]

N/A

Created automatically by system


N/A
[1..7200]
No,
Yes

N/A
0.0.0.0
10
Yes

N/A
N/A
s
N/A

[1..4]

N/A

N/A

Created automatically by system


N/A
[1..1]

N/A
0.0.0.0
1

N/A
N/A
N/A

Created automatically by system


[1..8]

N/A
N/A

N/A
N/A

Created automatically by system


[0..7]
[1..65535]
[1..65535]
[1..65535]

N/A
0
1
10
40

N/A
N/A
N/A
N/A
N/A

[0..255]

N/A

N/A

N/A

[1..60]

N/A

N/A

Created automatically by system


[5..60]

N/A
30

N/A
s

[5..60]

30

[30..300]

60

[1..10]

N/A

[1..64]
[1..64]
N/A

N/A
N/A
N/A

N/A
N/A
N/A

[1..4094]

N/A

N/A

Possible Means of Parameter Setting


Modification

EMS Path
Managed Element

Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
N/A
Managed Element/Equipment

Unmodifiable
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A

Managed Element/Equipment/Cabinet

Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
N/A

Managed Element/Equipment

Unmodifiable
N/A
Unmodifiable

Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment /BBU

Unmodifiable
Unmodifiable
Unmodifiable
N/A

N/A
N/A

N/A

Off-line modifications can be made through GUI.


Synchronizing the modified tables to BTS is required
to bring such modifications into effect.
Off-line modifications can be made through GUI.
Synchronizing the modified tables to BTS is required
to bring such modifications into effect.
Managed Element/Equipment
/BBU/BPL/Baseband Device Set/Baseband
Device

Unmodifiable

Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment
/BBU/CCC/Clock Device Set

Unmodifiable
Unmodifiable
N/A

N/A

N/A

N/A
Managed Element/Equipment
/BBU/CCC/Clock Device Set/Clock Device

Unmodifiable
Unmodifiable
N/A

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
N/A
N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A

N/A

Managed Element/Equipment /BBU/CCC/Time Unmodifiable


Device Set
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment /BBU/CCC/Time Unmodifiable
Device Set/Time Device
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment /RRU/RF
Device Set

Unmodifiable
Unmodifiable
N/A

N/A
Managed Element/Equipment /RRU/RF
Device Set/RF Port Object

Managed Element/Equipment /RRU/RF


Device Set/RF Port Object/PA

N/A
N/A
N/A
Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment /RRU/RF
Device Set/RF Port Object/Tx Device

Unmodifiable
Unmodifiable
Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
N/A
Managed Element/Equipment /RRU/RF
Device Set/RF Port Object/Rx Device

Unmodifiable
Unmodifiable

Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment /RRU/AISG
Device

Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable

Unmodifiable

Unmodifiable

Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Unmodifiable
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment
/BBU/BPL/Optical Port Device Set

Unmodifiable

Unmodifiable
Unmodifiable
N/A

Managed Element/Equipment
Unmodifiable
/BBU/BPL/Optical Port Device Set/Optical Port
Device
Unmodifiable
Unmodifiable
N/A
N/A

N/A

N/A

Managed Element/Equipment
/BBU/CCC/GigaBitEthernet

Unmodifiable
Unmodifiable
Modifying this parameter is deleting and recreating
the MO.

Managed Element/Equipment /BBU/SA/E1

Unmodifiable
Unmodifiable
Modifying this parameter is deleting and recreating
the MO.

Managed Element/Equipment /BBU/SA/T1

Unmodifiable
Unmodifiable
Modifying this parameter is deleting and recreating
the MO.

Managed Element/Equipment
/BBU/UES/Ethernet Switching Device Set

N/A
Unmodifiable
N/A
N/A
N/A
N/A

N/A

N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Managed Element/Equipment
/BBU/UES/Ethernet Switching Device Set

N/A
Unmodifiable
N/A

N/A

N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A

Managed Element/Equipment /BBU/PM/Power Unmodifiable


Device Set
Unmodifiable
N/A
Unmodifiable
Managed Element/Equipment /BBU/PM/Power Unmodifiable
Device Set/Power Device
Managed Element/Equipment /RRU/Dry
Contact Device

Unmodifiable
Unmodifiable
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Unmodifiable

Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Managed Element/Equipment
/RRU/Environment Monitoring Device

Unmodifiable

Managed Element/Equipment
/RRU/Environment Monitoring Device

Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment /BBU/SA/Fan
Device

Managed Element/Equipment
/BBU/TIM/Power Outlet Set

Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
N/A

N/A

Managed Element/Equipment
/BBU/TIM/Power Outlet Set/PowerOutlet

Unmodifiable
Unmodifiable
Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Managed Element/Equipment /BTS Auxiliary


Peripheral Device
Managed Element/Equipment /BTS Auxiliary
Peripheral Device/External device

Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Unmodifiable
Managed Element/Equipment /BTS Auxiliary
Peripheral Device/Antenna Service/TMA
Device

Unmodifiable

Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment /BTS Auxiliary
Peripheral Device/Antenna Service/Antenna
Attribute Object

Managed Element/Equipment /BTS Auxiliary


Peripheral Device/Antenna Service/Antenna
Entity Object

N/A

N/A
Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
N/A

N/A
N/A
Unmodifiable
N/A

N/A

N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Managed Element/Equipment /BTS Auxiliary


Peripheral Device/Antenna Service/Ir Antenna
Group Object

Managed Element/Equipment /BTS Auxiliary


Peripheral Device/Cable/RF Cable

N/A
N/A
N/A
N/A
N/A

N/A
Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Equipment /BTS Auxiliary
Peripheral Device/Cable/RF Extend Cable

Unmodifiable
Unmodifiable
N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Managed Element/Equipment /BTS Auxiliary


Peripheral Device/Cable/Fiber Cable

Unmodifiable
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Managed Element/Transmission Network

Unmodifiable
Unmodifiable

Managed Element/Transmission
Network/Physical Hosting/Physical Layer Port

N/A
Unmodifiable
N/A
N/A

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

N/A
N/A

N/A

N/A

Managed Element/Transmission Network/ATM Unmodifiable


Transport Network/ATM Layer Link
Unmodifiable
Unmodifiable
Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Modifying this parameter is deleting and recreating
the MO.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Off-line modifications can be made through GUI.


Synchronizing the modified tables to BTS is required
to bring such modifications into effect.
Managed Element/Transmission Network/ATM Unmodifiable
Transport Network/AAL2
Unmodifiable
Unmodifiable

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.
N/A

Modifying this parameter is deleting and recreating


the MO.
Managed Element/Transmission Network/ATM Unmodifiable
Transport Network/SaalUni
Unmodifiable
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
N/A
Modifying this parameter is deleting and recreating
the MO.
Managed Element/Transmission Network/ATM Unmodifiable
Transport Network/ALCAP
Unmodifiable

Modifying this parameter is deleting and recreating


the MO.
Managed Element/Transmission Network/BTS Unmodifiable
Cascade
Unmodifiable
Unmodifiable

Modifying this parameter is deleting and recreating


the MO.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.

N/A

Modifying this parameter is deleting and recreating


the MO.
N/A
N/A
Managed Element/Transmission Network/IP
Transport/HDLC Channel

Unmodifiable
Unmodifiable
Modifying this parameter is deleting and recreating
the MO.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Modifying this parameter is deleting and recreating
the MO.

Managed Element/Transmission Network/IP


Transport/PPP Link

Unmodifiable
Unmodifiable
Modifying this parameter is deleting and recreating
the MO.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Modifying this parameter is deleting and recreating
the MO.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Transmission Network/IP
Transport/LACP aggregation port

Unmodifiable
N/A

N/A
N/A
N/A

Managed Element/Transmission Network/IP


Transport/LACP aggregation group

N/A
Unmodifiable
Unmodifiable
N/A
N/A
N/A

N/A

Managed Element/Transmission Network/IP


Transport/Ethernet Link Layer

Unmodifiable
Unmodifiable
Unmodifiable
Unmodifiable
N/A

Modifying this parameter is deleting and recreating


the MO.
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
Managed Element/Transmission
Network/Network Detection/Ethernet Fault
Detection Configuration

Unmodifiable

Unmodifiable
Modifying this parameter is deleting and recreating
the MO.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
Modifying this parameter is deleting and recreating
the MO.
Managed Element/Transmission Network/IP
Transport/DHCP Relay Object

N/A
Unmodifiable
N/A

N/A
N/A

Managed Element/Transmission
Network/Bandwidth Assignment/Bandwidth
Resource Group

N/A
N/A

Unmodifiable
N/A

Modifying this parameter is deleting and recreating


the MO.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Transmission
Network/Bandwidth Assignment/Bandwidth
Resource Group/Bandwidth Resource

N/A

Unmodifiable
N/A
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Managed Element/Transmission
Network/Bandwidth Assignment/Bandwidth
Resource Group/Bandwidth
ResourceBandwidth QOS Queue

N/A

N/A
N/A

N/A
Managed Element/Transmission Network/IP
Transport/IP Layer Configuration

Unmodifiable
Unmodifiable
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.

Modifying this parameter is deleting and recreating


the MO.

Modifying this parameter is deleting and recreating


the MO.
Modifying this parameter is deleting and recreating
the MO.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
N/A

Managed Element/Transmission Network/IP


Transport/DSCP to COS mapping

N/A
N/A
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
Off-line modifications can be made through GUI.
Synchronizing the modified tables to BTS is required
to bring such modifications into effect.

Managed Element/Transmission
Network/Signalling and Business/Service and
DSCP mapping

N/A

N/A
N/A
N/A
N/A

N/A

N/A
Managed Element/Transmission
Network/Static Route

N/A
N/A
N/A

Off-line modifications can be made through GUI.


Synchronizing the modified tables to BTS is required
to bring such modifications into effect.

Off-line modifications can be made through GUI.


Synchronizing the modified tables to BTS is required
to bring such modifications into effect.

Off-line modifications can be made through GUI.


Synchronizing the modified tables to BTS is required
to bring such modifications into effect.
Off-line modifications can be made through GUI.
Synchronizing the modified tables to BTS is required
to bring such modifications into effect.
Off-line modifications can be made through GUI.
Synchronizing the modified tables to BTS is required
to bring such modifications into effect.

Off-line modifications can be made through GUI.


Synchronizing the modified tables to BTS is required
to bring such modifications into effect.

Managed Element/Transmission
Network/Network Detection/Routing Detection
Object

N/A
N/A
N/A

Unmodifiable
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Managed Element/Transmission
Network/Network Security/IKE Policy Object

N/A
N/A
N/A
N/A

N/A
N/A

N/A
N/A
N/A
N/A
Managed Element/Transmission
Network/Network Security/IPSec Proposal
Object

N/A

N/A
N/A
N/A
N/A
N/A
Managed Element/Transmission
Network/Network Security/IPSec Security
Policy Database Object

N/A

N/A
N/A

Managed Element/Transmission
Network/Network Security/XAUTH
Configuration Object

Managed Element/Transmission
Network/Network Security/IPSec Global
Configuration Object

N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
Managed Element/Transmission
N/A
Network/Network Security/IPSec Configuration
Object
N/A
N/A

N/A
N/A

N/A
N/A
N/A

N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
Managed Element/Transmission
N/A
Network/Network Security/Access Control Rule
Object
N/A
N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Managed Element/Transmission
Network/Network Security/Certificate
Revocation List Configuration

N/A

N/A

N/A

N/A

Managed Element/Transmission
Network/Network Security/Certificate
Management Protocol Configuration

N/A
N/A
N/A
N/A

Unmodifiable
N/A
N/A
N/A
N/A
N/A

N/A

N/A

N/A
N/A
N/A
N/A
Managed Element/Transmission
Network/Signalling and Business/SCTP

Unmodifiable
Unmodifiable

Modifying this parameter is deleting and recreating


the MO.
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
N/A
Modifying this parameter is deleting and recreating
the MO.

Modifying this parameter is deleting and recreating


the MO.

N/A

Modifying this parameter is deleting and recreating


the MO.
Modifying this parameter is deleting and recreating
the MO.

N/A

N/A

N/A

N/A

N/A

N/A

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Managed Element/Transmission
Network/Network Detection/Maintenance
Domain

N/A

N/A
N/A
N/A
N/A
N/A
N/A
Managed Element/Transmission
Network/Network Detection/Maintenance
Association

N/A

N/A
N/A
N/A

N/A
N/A
N/A
N/A

Managed Element/Transmission
N/A
Network/Network Detection/Maintenance Point
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Managed Element/Transmission
Network/Signalling and Business/UDP

Unmodifiable
Unmodifiable
N/A

Managed Element/Transmission
Network/Network Detection/Bidirectional
Forwarding Detection

Unmodifiable

Unmodifiable
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.

Modifying this parameter is deleting and recreating


the MO.

N/A

N/A

N/A
Modifying this parameter is deleting and recreating
the MO.
Managed Element/Transmission Network/IP
Clock/1588 Clock Global Parameter

N/A
Unmodifiable
Unmodifiable
N/A
Off-line modifications can be made through GUI.
Synchronizing the modified tables to BTS is required
to bring such modifications into effect.
N/A

Managed Element/Transmission Network/IP


Clock/IP Clock Parameters

Unmodifiable
Unmodifiable

Unmodifiable
N/A

Unmodifiable

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
N/A

N/A

Modifying this parameter is deleting and recreating


the MO.
Modifying this parameter is deleting and recreating
the MO.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
N/A
Managed Element/Transmission
N/A
Network/Network Detection/KPI Measurement
Unmodifiable
Unmodifiable

Managed Element/Transmission
Network/OMC Channel

N/A
N/A
N/A
N/A
Unmodifiable
Unmodifiable
Modifying this parameter is deleting and recreating
the MO.
N/A

Use GUI to modify parameters. Then perform the


delivering modified data operation so that the
modified data become valid at base station.

Modifying this parameter is deleting and recreating


the MO.

Unmodifiable
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Unmodifiable

Modifying this parameter is deleting and recreating


the MO.
Modifying this parameter is deleting and recreating
the MO.
Managed Element/Operator

N/A
Unmodifiable
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Managed Element/Operator/PLMN

Unmodifiable
Unmodifiable
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.
Use GUI to modify parameters. Then perform the
delivering modified data operation so that the
modified data become valid at base station.

Managed Element/System Parameter

N/A
N/A
N/A

N/A

N/A
N/A

N/A
Managed Element/System Parameter/Power
Saving Parameter

N/A
N/A
N/A
N/A
N/A
N/A
N/A

Managed Element/Equipment /BTS Auxiliary


Peripheral Device/Antenna Service

N/A
N/A
N/A
N/A
N/A

N/A

N/A
Managed Element/System Parameter/SON
Function Switch Object

N/A
N/A
N/A
N/A
N/A
N/A

Managed Element/Transmission
Network/Network Detection/OSPF Instance

N/A
N/A
N/A
N/A
N/A

Managed Element/Transmission
Network/Network Detection/OSPF
Instance/OSPF Area

Managed Element/Transmission
Network/Network Detection/OSPF
Instance/OSPF Area/OSPF stub settings

N/A

N/A
N/A
N/A

Managed Element/Transmission
Network/Network Detection/OSPF
Instance/OSPF Area/OSPF Interface

N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A
N/A
Managed Element/Transmission
Network/Network Security/DOT1X

N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
Modifying this parameter is deleting and recreating
the MO.
Modifying this parameter is deleting and recreating
the MO.

When to Take Effect

Impact on Service

Related Parameters

Reference Protocol

With immediate effect

N/A

N/A

3GPP TS32.622

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

3GPP TS32.622

With immediate effect

N/A

N/A

3GPP TS32.622

With immediate effect

N/A

N/A

3GPP TS32.622

With immediate effect

N/A

N/A

3GPP TS32.622

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

The parameter will only be valid after N/A


the whole table is reset.

N/A

N/A

With immediate effect


With immediate effect
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

N/A

N/A

N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

clockType

ITU g.8264

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

isSuppSummTime

N/A

With immediate effect

N/A

isSuppSummTime

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

radioMode

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

Affect the transmitting


frequency points
established on local object
cell.

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

Affect the receiving


frequency points
established on local object
cell.

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

isSyncEEnable

IEEE 802.1d

N/A

N/A

N/A

IEEE 802.1d

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

ITU-T I.363.2 B-ISDN


ATM Adaptation

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

protocolType

N/A

N/A

N/A

N/A

N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
With immediate effect

N/A
N/A

N/A
N/A

802.1Q
N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

dryType

N/A

With immediate effect

N/A

dryType

N/A

With immediate effect

N/A

dryType

N/A

With immediate effect

N/A

dryType

N/A

With immediate effect

N/A

dryType

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect


With immediate effect

N/A
Affect the power supply
status of normal tower
amplifier and AISG device.
Also affect the coverage
area of traffic signal.

N/A
N/A

N/A
N/A

With immediate effect

Affect the power supply


status of normal tower
amplifier and AISG device.
Also affect the coverage
area of traffic signal.

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

Affect the supplied power


N/A
current of tower amplifier.
Also affect the transmission
and receiving of service
signals.

N/A

N/A

N/A

N/A

N/A

It is required to perform the delivering N/A


modified data operation.

N/A

N/A

It is required to perform the delivering When the actual current is


modified data operation.
greater than 2*((working
current*(this
value/100))/1.2), the TAM
board will shut down the
power supply for this
channel, and then the
services are impacted.

N/A

N/A

With immediate effect

Affect the supplied power


N/A
current of tower amplifier.
Also affect the transmission
and receiving of service
signals.

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
Affect the carrier
configuration of site.

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

Affect the field strength


RSSI.

N/A

N/A

With immediate effect

Affect the field strength


RSSI.

N/A

N/A

With immediate effect

Affect the field strength


RSSI.

N/A

N/A

N/A

Affect the range to search


UE.

N/A

N/A

With immediate effect

Affect the range to search


UE.

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect
With immediate effect
With immediate effect
With immediate effect
With immediate effect
With immediate effect

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

With immediate effect


With immediate effect
With immediate effect
With immediate effect

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect


With immediate effect
N/A
With immediate effect

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

With immediate effect


With immediate effect
With immediate effect
With immediate effect
With immediate effect
With immediate effect
With immediate effect
With immediate effect
With immediate effect

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

With immediate effect

N/A

N/A

N/A

N/A
N/A
With immediate effect
With immediate effect
With immediate effect

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

With immediate effect


With immediate effect
With immediate effect
With immediate effect
With immediate effect

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

With immediate effect


N/A
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

Affect the range to search


UE.

N/A

N/A

With immediate effect

Affect the range to search


UE.

N/A

N/A

With immediate effect

N/A

connectType

N/A

With immediate effect

N/A

connectType

N/A

With immediate effect

N/A

connectType

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


N/A
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

Affect the range to search


UE.

N/A

N/A

With immediate effect

Affect the range to search


UE.

N/A

N/A

With immediate effect

N/A

connectType

N/A

With immediate effect

N/A

connectType

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

3GPP TS32.712

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

N/A

N/A

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

N/A

ITU-T G.704

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

N/A

IEEE802.3

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

N/A

IEEE802.3

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
The service or network
management information
borne by the link will be
interrupted.

N/A
N/A
N/A

N/A
N/A
IMA1.1

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

protocolType

IMA1.1

With immediate effect

N/A

protocolType

IMA1.1

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

protocolType

IMA1.1

With immediate effect

N/A

protocolType

ITU-T I.363.2 B-ISDN


ATM Adaptation

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

N/A

N/A

With immediate effect

The service or network


management information
borne by the link will be
interrupted.

protocolType

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


N/A

N/A
The service borne by the
link will be interrupted.

N/A
N/A

N/A
ITU-T I.363.2 B-ISDN
ATM Adaptation Layer
specification: Type 2
AAL
ITU-T Q.2630.3 AAL
type 2 signalling
protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

ITU-T I.363.2 B-ISDN


ATM Adaptation Layer
specification: Type 2
AAL
ITU-T Q.2630.3 AAL
type 2 signalling
protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

ITU-T I.363.2 B-ISDN


ATM Adaptation Layer
specification: Type 2
AAL
ITU-T Q.2630.3 AAL
type 2 signalling
protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

N/A

N/A

N/A

ITU-T I.363.2 B-ISDN


ATM Adaptation Layer
specification: Type 2
AAL
ITU-T Q.2630.3 AAL
type 2 signalling
protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
The service borne by the
link will be interrupted.

N/A
N/A

N/A
N/A

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

The service borne by the


link will be interrupted.

N/A

IMA1.1
ITU-T I.363.2 B-ISDN
ATM Adaptation

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A
The service from the lower- N/A
level base station, which is
borne by the link, will be
interrupted.

N/A
N/A

With immediate effect

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

N/A

With immediate effect

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

N/A

With immediate effect

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

N/A

With immediate effect

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

N/A

With immediate effect

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

ITU-T I.363.2 B-ISDN


ATM Adaptation

N/A

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

ITU-T I.363.2 B-ISDN


ATM Adaptation

N/A

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

AF-PHY-0086.000 AFPHY-0086.001
ITU-T I.363.2 B-ISDN
ATM Adaptation

N/A

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

ITU-T I.363.2 B-ISDN


ATM Adaptation

N/A

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

ITU-T I.363.2 B-ISDN


ATM Adaptation

N/A

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

AF-PHY-0086.000 AFPHY-0086.001
ITU-T I.363.2 B-ISDN
ATM Adaptation

N/A

The service from the lower- cascadeType


level base station, which is
borne by the link, will be
interrupted.

N/A

N/A

N/A

cascadeType

AF-PHY-0086.000 AFPHY-0086.001
ITU-T I.363.2 B-ISDN
ATM Adaptation

With immediate effect

N/A

cascadeType

N/A

With immediate effect

N/A

cascadeType

N/A

With immediate effect

N/A

cascadeType

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
The service borne by the
link will be interrupted.

N/A
N/A

N/A
ISO/IEC 13239:2002

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

RFC 1661 The Point-toPoint Protocol (PPP)

With immediate effect

N/A

protocolType

RFC 1663 The Point-toPoint Protocol (PPP)

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC 1990 The PPP


Multilink Protocol (MP)

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC 1990 The PPP


Multilink Protocol (MP)

With immediate effect

N/A

protocolType

With immediate effect

N/A

protocolType

RFC 1332 The PPP


Internet Protocol
Control Protocol (IPCP)
RFC 2686 The MultiClass Extension to
Multi-Link
PPP(MCPPP)
RFC 2509 IP Header
Compression over
PPP(IPHC)

With immediate effect

N/A

N/A

RFC 1661 The Point-toPoint Protocol (PPP)

With immediate effect

N/A

protocolType

N/A

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

N/A

N/A

RFC 1661 The Point-toPoint Protocol (PPP)

With immediate effect

When there is another


protocolType
HDLC, the service borne by
the link will be interrupted.

RFC 1661 The Point-toPoint Protocol (PPP)

With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

N/A
With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
802.1Q

N/A

N/A

N/A

802.1Q

With immediate effect

N/A

N/A

802.1Q

With immediate effect

The service borne by the


link will be interrupted.

N/A

802.1Q

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

IEEE 802.3ah
IEEE 802.3ah

With immediate effect

N/A

N/A

IEEE 802.3ah

With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

802.1Q

With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
RFC795

With immediate effect

The service will be


interrupted after the
parameter is modified.

N/A

N/A

With immediate effect

N/A

N/A

RFC795

N/A

N/A

N/A

N/A

With immediate effect


N/A
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
RFC795
N/A

N/A

N/A

N/A

N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
RFC794:Internet
Protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

802.1Q

With immediate effect

The service borne by the


link will be interrupted.

N/A

802.1Q

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC795:Internet
Protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC795:Internet
Protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC794:Internet
Protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC794: Internet
Protocol

With immediate effect

The service will be


interrupted after the
parameter is modified.

N/A

RFC794:Internet
Protocol

N/A

N/A

refEthernetLink

RFC 1663 The Point-toPoint Protocol (PPP)

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
With immediate effect

N/A
The service borne by the
link will be interrupted.

N/A
N/A

N/A
RFC 2960:Stream
Control Transmission
Protocol

With immediate effect

N/A

N/A

RFC 2474

With immediate effect

N/A

N/A

802.1q

N/A

N/A

N/A

N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
RFC 894: Standard for
the transmission of IP
datagrams over
Ethernet
networks
RFC 1812:
Requirements for IP
Version 4 Routers

With immediate effect

N/A

N/A

RFC 894:Standard for


the transmission of IP
datagrams over
Ethernet
networks.
RFC 1812:
Requirements for IP
Version 4 Routers.

With immediate effect

N/A

N/A

RFC 894:Standard for


the transmission of IP
datagrams over
Ethernet
networks.
RFC 1812:
Requirements for IP
Version 4 Routers.

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

RFC 894:Standard for


the transmission of IP
datagrams over
Ethernet
networks.
RFC 1812:
Requirements for IP
Version 4 Routers.

With immediate effect

N/A

N/A

N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

With immediate effect


N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
With immediate effect
With immediate effect
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

N/A

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

N/A

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A
N/A

N/A
N/A

N/A
N/A

N/A
RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A
N/A

N/A
N/A

N/A
N/A

N/A
RFC4301
RFC4306

N/A
N/A

N/A
N/A

N/A
N/A

N/A
RFC4301
RFC4306

N/A

N/A

N/A

N/A

N/A

N/A

N/A

RFC4301
RFC4306

N/A

N/A

N/A

RFC4301
RFC4306

N/A
N/A

N/A
When the service is borne
on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A
N/A

N/A
N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

When the service is borne


on the IP or IP section
configured by the rule, if it
does not meet the filtering
rule, the service will be
interrupted.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

With immediate effect

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC 2960:Stream
Control Transmission
Protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC 2960:Stream
Control Transmission
Protocol

N/A
With immediate effect

N/A
The service borne by the
link will be interrupted.

N/A
N/A

N/A
RFC 2960:Stream
Control Transmission
Protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

N/A

N/A

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

With immediate effect

The service borne by the


link will be interrupted.

N/A

RFC2474
RFC2475

With immediate effect

When the network quality is N/A


low, the service cell
corresponding to the
association will be deleted.

N/A

N/A

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

N/A

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

N/A

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

N/A

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

N/A

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

N/A

N/A

N/A

RFC 2960:Stream
Control Transmission
Protocol

With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

N/A

N/A

802.1ag

N/A
N/A

N/A
N/A

N/A
N/A

802.1ag
N/A

N/A

N/A

N/A

N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
refEthernetLink
N/A

N/A
802.1ag
802.1ag

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
802.1ag

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

mepType

N/A

N/A

N/A

mepType

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

N/A

The service borne by the


link will be interrupted.

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect

N/A

N/A

RFC2474
RFC2475

With immediate effect

N/A

N/A

RFC5883
RFC5881

With immediate effect

N/A

N/A

The attribute is
compliant with the
following draft released
by BFD team in June,
2006:
Jun 06, draft-ietf-bfdbase-05.txt
Jun 06, draft-ietf-bfdgeneric-02.txt
Jun 06, draft-ietf-bfdmultihop-04.txt
Jun 06, draf-tietf-bfdv4v6-1hop-05.txt

With immediate effect

N/A

N/A

The attribute is
compliant with the
following draft released
by BFD team in June,
2006:
Jun 06, draft-ietf-bfdbase-05.txt
Jun 06, draft-ietf-bfdgeneric-02.txt
Jun 06, draft-ietf-bfdmultihop-04.txt
Jun 06, draf-tietf-bfdv4v6-1hop-05.txt

With immediate effect

N/A

N/A

The attribute is
compliant with the
following draft released
by BFD team in June,
2006:
Jun 06, draft-ietf-bfdbase-05.txt
Jun 06, draft-ietf-bfdgeneric-02.txt
Jun 06, draft-ietf-bfdmultihop-04.txt
Jun 06, draf-tietf-bfdv4v6-1hop-05.txt

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

N/A

With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A

With immediate effect

N/A

N/A

IEEE 1588

N/A

N/A

N/A

IEEE 1588

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

IEEE 1588

With immediate effect


N/A

N/A
N/A

N/A
N/A

IEEE 1588
IEEE 1588

With immediate effect

N/A

N/A

IEEE 1588

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

IEEE 1588

N/A

N/A

N/A

IEEE 1588

N/A

N/A

N/A

IEEE 1588

N/A

N/A

N/A

IEEE 1588

With immediate effect

The service borne by the


link will be interrupted.

N/A

802.1Q

With immediate effect

The service borne by the


link will be interrupted.

refEthernetLink

RFC795:Internet
Protocol

With immediate effect

N/A

N/A

N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A
N/A
With immediate effect
With immediate effect

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
3GPP TS32.101
N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

itfUniBtsType

N/A

With immediate effect

N/A

itfUniBtsType

N/A

With immediate effect

N/A

itfUniBtsType

N/A

With immediate effect

N/A

itfUniBtsType

RFC2474
RFC2475

With immediate effect

N/A

itfUniBtsType

RFC1936 IP over ATM:


A Framework
Document

With immediate effect

N/A

itfUniBtsType

N/A

With immediate effect

N/A

itfUniBtsType

N/A

With immediate effect

N/A

itfUniBtsType

N/A

With immediate effect

N/A

itfUniBtsType

N/A

N/A
With immediate effect
With immediate effect
With immediate effect

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect


With immediate effect
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


With immediate effect
With immediate effect
With immediate effect

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

With immediate effect


N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A

N/A

N/A

N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

N/A
With immediate effect

N/A
N/A

N/A
N/A

N/A
IEEE Std 802.1X-2004

With immediate effect

N/A

N/A

IEEE Std 802.1X-2004

With immediate effect

N/A

N/A

IEEE Std 802.1X-2004

With immediate effect

N/A

N/A

IEEE Std 802.1X-2004

With immediate effect


With immediate effect
With immediate effect

N/A
N/A
The service borne by the
link will be interrupted.

N/A
N/A
N/A

N/A
N/A
802.1Q

With immediate effect

The service borne by the


link will be interrupted.

refEthernetLink

RFC795:Internet
Protocol

Parameter Explanation
Network element type, such as NodeB and BTS.

Change Records
No change

Unique identification of the NE. It is used to distinguish different NEs. No change

Network element name.

No change

Geographical information of the network element.

No change

Software version of network element.

No change

Running status customized by the operator for special purposes.

No change

Longitude of the network element. It is used to display the network


topology.

No change

Latitude of the network element. It is used to display the network


topology.

No change

The unique network element ID planned by the operator for base


station. Can be empty if it is not planned.

No change

The unique network element ID planned by the vendor for base


station. Can be empty if it is not planned.

No change

Relative Distinguished Name (RDN).


User-oriented description of the object.
Customized information.

No change
No change
No change

Single base station can use 2 BBU frames. The stack mode can
extend the capacity and coverage of single site.
In stack mode, 2 BBU frames are taken as one site for service,
operation maintenance, transmission, and clock functions.
In non-stack mode, only 1 BBU frame exists, and the frame number
is 1.
The configuration only takes effect when the base station is reset.

No change

Relative Distinguished Name (RDN).


User-oriented description of the object.
Unique identification of the cabinet. The master rack cabinet number
is fixed to 1.

No change
No change
No change

Cabinet type information.


No change
Cabinet position describes the position relation between the cabinet No change
and other cabinets. It is auto-generated according to certain rules. Do
not
needDistinguished
to be customized
by (RDN).
users.
Relative
Name
No change
User-oriented description of the object.
No change
Sub-rack number. It is unique within the rack.
No change

Specify subrack type.

No change

Customized information.

No change

Relative Distinguished Name (RDN).


User-oriented description of the object.
Product information of the board, including board name and board
number.

No change
No change
No change

Board Radio Mode

No change

The function mode used by the board when in working status.


It is used to distinguish different physical boards of the same logical
type.

No change
No change

Indicate the power-supply level needed by the board. By default, the No change
level is set to low priority. When load is shared, NE is allocated
automatically according to the enhanced load sharing algorithm. In
OMMB, it can be manually adjusted to high priority, and then both PM
boards supply power for the board. If boards exceed half of the
boards in the rack, do not set all the power-supply levels to high
priority, otherwise board power configured may exceed the upper limit
of total PM power.
Indicate the feeder length from the GNSS antenna to the receiver.
This feeder is used to improve the clock precision. It should be set
based on the on-site survey. It can only be set on at most three
RRUs. Only R8964T S2600 need to be configured.

No change

Indicate minimum number of satellites for satellite timing. It is also the No change
parameter of satellite alarm threshold and the default value is 4. Only
R8964T S2600 need to be configured.
Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


The unit number is unique within a board.

No change
No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


Synchronization mode of site and clock reference source.

No change
No change

Multiple clock reference sources are configured on the main control


board. It indicates the switching strategy between clock reference
sources when one clock reference source is faulty.

No change

Clock cascading output type on main control board.

No change

Set to Yes if this clock is set to backup referenced clock by two BBUs. No change
Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


No change
Corresponding clock reference source categories need to be selected No change
according to different scenarios.

Corresponding clock reference source types are selected according No change


to different clock reference source categories.
For GNSS category clock, inner GNSS clock is selected when
accessing GPS on CC board SMA interface.
External backplane GNSS clock is selected when the 5th slot of BBU2U or 7th slot of BBU 3U accesses UCI or USR.
External panel GNSS clock is selected when the 5th slot of BBU-2U
or 7th slot of BBU 3U accesses USR, or when other AMC slot
accesses UCI. The reference clock source is accessed with cables on
the CC front panel HDMI interface.

The priority of the clock reference source. 1 indicates the highest


priority.

No change

External cable delay compensation value.


It can be configured when the clock reference source type is
'SyncE+1588 clock'.

No change
No change

Indicates whether the clock upload mode is Synchronization Status


No change
Message (SSM). SSM is the quality level for sending timing signals
through the timing synchronization link in the synchronization
network.
The node clock in the synchronization network obtains the parentnode clock information by reading the SSM, and performs related
operations on the clock of local node, such as tracing and
changeover. Meanwhile the synchronization message of local node is
sent to the subordinate node.
It can be configured when the clock reference source type is
'SyncE+1588 clock' or 'SyncE clock'.
Indicate the feeder length from the GNSS antenna to the receiver.
This feeder is used to improve the clock precision. It should be set
based on the on-site survey.

No change

Indicate the operating mode configuration of the GNSS receiver.


"Fixed Mode" is recommended but "Survey In" is not recommended.

No change

When the operating mode of the receiver is "Fixed Mode", set the
longitude of the receiver antenna to help the receiver obtain the
satellite clock.

No change

When the operating mode of the receiver is "Fixed Mode", set the
latitude of the receiver antenna to helps the receiver obtain the
satellite clock.

No change

When the operating mode of the receiver is "Fixed Mode", set the
No change
altitude of the receiver antenna to help the receiver obtain the satellite
clock.
Indicate minimum number of satellites for satellite timing. It is also the No change
parameter of satellite alarm threshold and the default value is 4.
Indicate the length of cable used for clock cascade. The cable length No change
can improve the clock precision. It should be set based on the on-site
survey.
Indicate the entered baud rate.

No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


Use standby server to synchronize time when the active server is
abnormal.

No change
No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


No change
The base station performs time synchronization with the NTP with the No change
period. Unit: hour.
The base station obtains time from the server by NTP protocol.

No change

Indicates the time zone of the base station.

No change

Configure whether to support daylight saving time.

No change

Indicates the start time of daylight saving time. The cross-year range
is allowed.

No change

Indicates the end time of daylight saving time. The cross-year range
is allowed.

No change

Indicate whether to enable SNTP time synchronization function.

No change

When the daylight saving time is enabled, it is used to configure its


offset (time granularity is 15 minutes).

No change

RDN

No change

User-oriented description of the object.


No change
It is to configure the diversity receiving mode of RU. 'Cross diversity No change
reception' indicates the signals received in two receiving channels are
mutually main/diversity set. (Dual-transmitting RU are connected with
and only with two receiving/transmitting antennas)
Specify antenna polarization mode.

No change

Specify object ID of RF port.

No change

User-oriented description of the object.


Identification of the antenna entity.
Specify object ID of PA device.

No change
No change
No change

User-oriented description of the object.


Indicate the rated power of the power amplifier. It is also the
maximum output power.

No change
No change

Indicate the working frequency bands supported by the power


No change
amplifier devices. For details about frequency band definition, see the
protocol of each product.
1.(Rx: 351MHz-356MHz, Tx: 361MHz-366MHz)(); 2.(Rx: 410MHz420MHz, Tx: 420MHz-430MHz)(CDMA BC5); 3.(Rx: 450MHz460MHz, Tx: 470MHz-480MHz)(); 4.(Rx: 698MHz-716MHz, Tx:
728MHz-746MHz)(UMTS Band XII, FDD 12); 5.(Rx: 777MHz798MHz, Tx: 746MHz-768MHz)(UMTS Band XIII, UMTS Band XIV,
FDD 13, FDD 14); 6.(Rx: 832MHz-862MHz, Tx: 791MHz-821MHz)
(UMTS Band XX, FDD 20); 7.(Rx: 806MHz-824MHz, Tx: 851MHz869MHz)(CDMA BC10); 8.(Rx: 894MHz-896MHz, Tx: 849MHz851MHz)(CDMA ATG); 9.(Rx: 820MHz-849MHz, Tx: 865MHz894MHz)(); 10.(Rx: 880MHz-915MHz, Tx: 925MHz-960MHz)(UMTS
Band VIII, GSM EMHz-GSM, FDD 8); 11.(Rx: 1710MHz-1770MHz,
Tx: 2110MHz-2170MHz)(UMTS Band I, CDMA BC6, FDD 1); 12.(Rx:
1710MHz-1785MHz, Tx: 1805MHz-1880MHz)(UMTS Band III, FDD 3
GSM DSC 1800); 13.(Rx: 1850MHz-1915MHz, Tx: 1930MHz1995MHz)(); 14.(Rx: 1920MHz-1980MHz, Tx: 2110MHz-2170MHz)();
15.(Rx:
2500MHz-2570MHz,
Tx:the
2620MHz-2690MHz)(UMTS
The sub-frequency
band within
working frequency band Band
No change
VII,
FDD 7);
Tx:attribute
460MHz-470MHz)(CDMA
supported
by16.(Rx:
the PA 450MHz-460MHz,
device. It is a unique
of the GSM
BC
5); 17.(Rx:
704MHz-716MHz,
734MHz-746MHz)();
18.(Rx:
system.
Only the
RU of 900M andTx:
1800M
have sub-frequency
bands.
824MHz-849MHz,
Tx: 869MHz-894MHz)(UMTS
Band V,
FDD 6,
900M (Band VIII) includes
the following sub-frequency
bands:
GSM
850, CDMA
BC 0);
19.(Rx:
1447.9MHz-1462.9MHz,
Tx:
1. Working
frequency
band:
uplink
890MHz to 915MHz, downlink
1495.9MHz-1510.9MHz)(UMTS
Band XXI, FDD 21); 20.(Rx:
935MHz to 960MHz.
1710MHz-1755MHz,
2110MHz-2155MHz)(UMTS
Band
IV, FDD
2. Working frequencyTx:
band:
uplink 880MHz to 905MHz,
downlink
4); 21.(Rx:
Tx: 1930MHz-1990MHz)(UMTS
925MHz
to 1850MHz-1910MHz,
950MHz.
Band
II, FDD
2, GSM PCS
BC to
1);906MHz,
22.(Rx1427MHz3. Working
frequency
band:1900,
uplinkCDMA
888MHz
downlink
1525MHzTx1427MHz-1525MHz)()23.(Rx1785MHz935MHz to 951MHz.
1805MHzTx1785MHz-1805MHz)()51.(1900MHz-1920MHz)
1800M (Band III) includes the following sub-frequency bands:
(TDD
33, TD
A); 52.(2010MHz-2025MHz)(TDD
TD A); 53.
1. Working
frequency
band: uplink 1710MHz to 34,
1765MHz,
downlink
(1850MHz-1910MHz)(TDD
35, TD B); 54.(1930MHz-1990MHz)(TDD
1805MHz
to 1860MHz.
36,
TD B); 55.(1910MHz-1930MHz)(TDD
37, to
TD1785MHz,
C); 56.(2570MHz2. Working
frequency band: uplink 1730MHz
downlink
2620MHz)(TDD
38, TD D); 57.(1880MHz-1920MHz)(TDD 39, TD F);
1825MHz
to 1880MHz.
58.(2300MHz-2400MHz)(TDD 40, TD E); 59.(2496MHz-2690MHz)
(TDD 41, TD tbd); 60.(3400MHz-3600MHz)(TDD 42, TD tbd); 61.
(3500MHz-3700MHz)(TDD 43, TD tbd);

Indicates the radio standard of the PA device service, such as GSM


or UMTS.

No change

The allocation method of PA resources in dual-mode. For example,


2G+2U indicates the PA supports 2 GSM carriers and 2 UMTS cells.

No change

The switch of PA shutdown function for idle time slot. When the switch No change
is enabled, in idle time slot without transmitted data, the PA power
supply can be shut down to save energy.
Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


Indicate the working frequency bands supported by the power
amplifier devices. For details about frequency band definition, see the
protocol of each product.
1.(Rx: 351MHz-356MHz, Tx: 361MHz-366MHz)(); 2.(Rx: 410MHz420MHz, Tx: 420MHz-430MHz)(CDMA BC5); 3.(Rx: 450MHz460MHz, Tx: 470MHz-480MHz)(); 4.(Rx: 698MHz-716MHz, Tx:
728MHz-746MHz)(UMTS Band XII, FDD 12); 5.(Rx: 777MHz798MHz, Tx: 746MHz-768MHz)(UMTS Band XIII, UMTS Band XIV,
FDD 13, FDD 14); 6.(Rx: 832MHz-862MHz, Tx: 791MHz-821MHz)
(UMTS Band XX, FDD 20); 7.(Rx: 806MHz-824MHz, Tx: 851MHz869MHz)(CDMA BC10); 8.(Rx: 894MHz-896MHz, Tx: 849MHz851MHz)(CDMA ATG); 9.(Rx: 820MHz-849MHz, Tx: 865MHz894MHz)(); 10.(Rx: 880MHz-915MHz, Tx: 925MHz-960MHz)(UMTS
Band VIII, GSM EMHz-GSM, FDD 8); 11.(Rx: 1710MHz-1770MHz,
Tx: 2110MHz-2170MHz)(UMTS Band I, CDMA BC6, FDD 1); 12.(Rx:
1710MHz-1785MHz, Tx: 1805MHz-1880MHz)(UMTS Band III, FDD 3
GSM DSC 1800); 13.(Rx: 1850MHz-1915MHz, Tx: 1930MHz1995MHz)(); 14.(Rx: 1920MHz-1980MHz, Tx: 2110MHz-2170MHz)();
15.(Rx: 2500MHz-2570MHz, Tx: 2620MHz-2690MHz)(UMTS Band
The
central
frequency point
TxChannel. It is
VII, FDD
7);transmission
16.(Rx: 450MHz-460MHz,
Tx:of460MHz-470MHz)(CDMA
unavailable
for 704MHz-716MHz,
users. When it is set
0, the calculation is 18.(Rx:
executed
BC 5); 17.(Rx:
Tx:to734MHz-746MHz)();
automatically.
In
special
cases
when
the
parameter
needs
to
824MHz-849MHz, Tx: 869MHz-894MHz)(UMTS Band V, FDDbe6,
configured,
contact
the
local1447.9MHz-1462.9MHz,
branch.
GSM 850, CDMA
BC
0);ZTE
19.(Rx:
Tx:
1495.9MHz-1510.9MHz)(UMTS
Band
XXI,
FDD
21);
20.(Rx:
Indicates whether to enable balance detection between main set and
1710MHz-1755MHz,
Tx: 2110MHz-2155MHz)(UMTS Band IV, FDD
diversity.
4); 21.(Rx: 1850MHz-1910MHz, Tx: 1930MHz-1990MHz)(UMTS
Relative
Distinguished
Name
(RDN).
Band II, FDD
2, GSM PCS
1900,
CDMA BC 1); 22.(Rx1427MHz1525MHzTx1427MHz-1525MHz)()23.(Rx1785MHzUser-oriented description of the object.
1805MHzTx1785MHz-1805MHz)()51.(1900MHz-1920MHz)
(TDD 33, TD A); 52.(2010MHz-2025MHz)(TDD 34, TD A); 53.
(1850MHz-1910MHz)(TDD 35, TD B); 54.(1930MHz-1990MHz)(TDD
36, TD B); 55.(1910MHz-1930MHz)(TDD 37, TD C); 56.(2570MHz2620MHz)(TDD 38, TD D); 57.(1880MHz-1920MHz)(TDD 39, TD F);
58.(2300MHz-2400MHz)(TDD 40, TD E); 59.(2496MHz-2690MHz)
(TDD 41, TD tbd); 60.(3400MHz-3600MHz)(TDD 42, TD tbd); 61.
(3500MHz-3700MHz)(TDD 43, TD tbd);

No change
No change

No change

No change
No change
No change

Indicate the working frequency bands supported by the power


amplifier devices. For details about frequency band definition, see the
protocol of each product.
1.(Rx: 351MHz-356MHz, Tx: 361MHz-366MHz)(); 2.(Rx: 410MHz420MHz, Tx: 420MHz-430MHz)(CDMA BC5); 3.(Rx: 450MHz460MHz, Tx: 470MHz-480MHz)(); 4.(Rx: 698MHz-716MHz, Tx:
728MHz-746MHz)(UMTS Band XII, FDD 12); 5.(Rx: 777MHz798MHz, Tx: 746MHz-768MHz)(UMTS Band XIII, UMTS Band XIV,
FDD 13, FDD 14); 6.(Rx: 832MHz-862MHz, Tx: 791MHz-821MHz)
(UMTS Band XX, FDD 20); 7.(Rx: 806MHz-824MHz, Tx: 851MHz869MHz)(CDMA BC10); 8.(Rx: 894MHz-896MHz, Tx: 849MHz851MHz)(CDMA ATG); 9.(Rx: 820MHz-849MHz, Tx: 865MHz894MHz)(); 10.(Rx: 880MHz-915MHz, Tx: 925MHz-960MHz)(UMTS
Band VIII, GSM EMHz-GSM, FDD 8); 11.(Rx: 1710MHz-1770MHz,
Tx: 2110MHz-2170MHz)(UMTS Band I, CDMA BC6, FDD 1); 12.(Rx:
1710MHz-1785MHz, Tx: 1805MHz-1880MHz)(UMTS Band III, FDD 3
GSM DSC 1800); 13.(Rx: 1850MHz-1915MHz, Tx: 1930MHz1995MHz)(); 14.(Rx: 1920MHz-1980MHz, Tx: 2110MHz-2170MHz)();
15.(Rx: 2500MHz-2570MHz, Tx: 2620MHz-2690MHz)(UMTS Band
VII, FDD
7);receiving
16.(Rx: 450MHz-460MHz,
460MHz-470MHz)(CDMA
The
central
frequency point ofTx:
RxChannel.
It is unavailable
BC
5); 17.(Rx:
704MHz-716MHz,
Tx: 734MHz-746MHz)();
for users.
When
it is set to 0, the calculation
is executed 18.(Rx:
824MHz-849MHz,
Tx: 869MHz-894MHz)(UMTS
Band
V, FDD
automatically.
In special
cases when the parameter
needs
to be6,
GSM
850, CDMA
BC
0);ZTE
19.(Rx:
Tx:
configured,
contact
the
local1447.9MHz-1462.9MHz,
branch.
1495.9MHz-1510.9MHz)(UMTS Band XXI, FDD 21); 20.(Rx:
Relative DistinguishedTx:
Name
(RDN).
1710MHz-1755MHz,
2110MHz-2155MHz)(UMTS
Band IV, FDD
4); 21.(Rx: 1850MHz-1910MHz, Tx: 1930MHz-1990MHz)(UMTS
Band
II, FDD 2,
GSM PCSof1900,
CDMA BC 1); 22.(Rx1427MHzUser-oriented
description
the object.
1525MHzTx1427MHz-1525MHz)()23.(Rx1785MHzUnique serial number for device.
1805MHzTx1785MHz-1805MHz)()51.(1900MHz-1920MHz)
The selected
device
type according to actual situation
the
(TDD
33, TD A);
52.(2010MHz-2025MHz)(TDD
34, TDwhen
A); 53.
reported
device type is scanned,
orB);
when
the device type is actively
(1850MHz-1910MHz)(TDD
35, TD
54.(1930MHz-1990MHz)(TDD
configured
by LMT/OMCB.
36, TD B); 55.(1910MHz-1930MHz)(TDD
37, TD C); 56.(2570MHz2620MHz)(TDD 38, TD D); 57.(1880MHz-1920MHz)(TDD 39, TD F);
58.(2300MHz-2400MHz)(TDD 40, TD E); 59.(2496MHz-2690MHz)
(TDD 41, TD tbd); 60.(3400MHz-3600MHz)(TDD 42, TD tbd); 61.
(3500MHz-3700MHz)(TDD 43, TD tbd);

No change

The entered vendor code according to actual situation when the


reported device type is scanned, or when the device type is actively
configured by LMT/OMCB.

No change

No change

No change
No change
No change
No change

The entered AISG version number according to actual situation when No change
the reported device type is scanned, or when the device type is
actively configured by LMT/OMCB.
The AISG1.1 and AISG2.0 Single RET devices are invalid. For other
AISG2.0 devices, each sub-unit number corresponds to an AISG
device that can be controlled independently.

No change

Customized information.

No change

The superior channel is used for SDTMA device of NSN private


protocol. The value for other devices is 0.

No change

The local channel is used for SDTMA device of NSN private protocol. No change
The value for other devices is 0.
Select the TMA controller unit to be connected.

No change

The antenna connected with the RF cable.

No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


The working mode of IQ switching. The boards with IQ switching
function can only be configured to load sharing mode.

No change
No change

Uplink connection mode.

No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


The physical port number.
The physical port is attached to RU board or not.

No change
No change
No change

The physical port rate (matched with the optical module type and the
SFP port type).

No change

The protocol type used by the optical module.

No change

Wireless radio mode.

No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


The physical port number 0,2,4,6indicates the Iub/Abis interface. 1
indicates the Debug port.

No change
No change

Relative Distinguished Name (RDN).


User-oriented description of the object.
The E1 port number.

No change
No change
No change

Relative Distinguished Name (RDN).


User-oriented description of the object.
The T1 port number.

No change
No change
No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


Indicates whether to use SyncE to send clock to cascading device.

No change
No change

Configures the Phase Locked Loop (PLL) reference clock source.

No change

Indicates whether to enable link aggregation function.

No change

Indicates the media type for link aggregation: optical or electrical port. No change

Indicates the media access type on the uplink interface.

No change

Require two independent uplink interfaces when this function is


enabled.

Modified

Indicate queue priority

No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


No change
Port configuration on the board. Different ports have different
No change
functions, including optical ports, electrical ports, and switching ports.

Indicate whether to enable the port. The parameter is invalid when


the port is set to 'backboard SGMII interface CC1 interface' or
'backboard SGMII interface CC2 interface'.

No change

The Uplink interface is connected to RNC/BSC/CN. The cascading


port is connected to subordinate SDR.

No change

Self Negotiation mode is the mode that is automatically adaptable to


the other end.

No change

Configure rate limitation switch, indicates whether to enable ingress


rate limitation or not.

No change

Limit of the ingress transmission rate.


Configure rate limitation switch, indicates whether to enable egress
rate limitation or not.

No change
No change

Limit of the egress transmission rate.


No change
Specifies the belonging VLAN group number for the current port. Port No change
6 (SGMII port CC1 port on the backplane) and port 7 (SGMII port
CC2 port on the backplane) cannot be configured in the same VLAN
group.

Configure the mode of ingress rate limitation.

No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


Configure the working mode for the boards with power device
functions.

No change
No change

Configure the control mode for power-down

No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.


RDN

No change
No change

User-oriented description of the object.


Customized information by the user.

No change
No change

The dry contact port number on which dry contact alarms are
configured. Supported by the SA, FCE series boards and radio
frequency boards.

No change

Indicates whether the current dry contact number is used for


configuration of input dry contact or output dry contact.

No change

The configuration status of output dry contact. Valid when the dry
contact type is output dry contact.

No change

Customized description of output dry contact. Valid when the dry


contact type is output dry contact.

No change

The switch of dry contact alarm. Valid when the dry contact type is
input dry contact.

No change

Indicates whether the dry contact alarm is customized. Valid when the No change
dry contact type is input dry contact. The customized dry contact
needs to be imported by the user.
Configure the content of dry contact alarms. You can customize dry
contact to configure or select built-in dry contact alarms.

No change

RDN

No change

User-oriented description of the object.


RDN

No change
No change

User-oriented description of the object.


The RF port number on RU.

No change
No change

The type of environment monitoring.

No change

Upper limit of environment monitoring.

No change

Lower limit of environment monitoring.

No change

The upper limit alarm recovery value of environment monitoring. Can No change
be modified.
The lower limit alarm recovery value of environment monitoring. Can
be modified.

No change

RDN

No change

User-oriented description of the object.


Fan number.
RDN

No change
No change
No change

User-oriented description of the object.


No change
Configure switch for AISG/NSBT and for RS485 to select the AISG or No change
NSBT channel. The switch is not available for the TAM board.

The voltage of AISG and NSBT.

No change

RDN

No change

User-oriented description of the object.


Power outlet port number.

No change
No change

Indicates the working current value of the port.

No change

The alarm is reported when the current of the port is abnormal.


Configure this parameter for the detection mode of output current

No change

When the actual current value of the TAM board and RSU internal
NSBT's power supply channel is lower than the value of (Working
Current Value*local value/100), low current alarm is raised.

No change

When the actual current value of the TAM board and RSU internal
NSBT's power supply channel is higher than the value of (Working
Current Value*local value/100), over current alarm is raised.

No change

Configure the switch status of whether to enable current control.

No change

RDN

No change

User-oriented description of the object.


Specify object ID of external device.

No change
No change

User-oriented description of the object.


Indicate the mode for NE to process related data (such as alarm and
configuration data) of embedded power and shelter devices.
Transparent transmission indicates that the data is transmitted
without being processed. Parsing mode indicates that the data is
parsed by base station itself or uploaded to OMC to parse.

No change
No change

Specify the external device type.

No change

Indicate the board (SA/SE/RU) for BBU to connect to the external


device.

No change

RDN

No change

User-oriented description of the object.


TMA number.

No change
No change

A-TMA corresponds to the AISG tower mounted amplifier.


A-COM corresponds to the AISG combiner.
TMA corresponds to common tower mounted amplifier.
ETMA corresponds to high-gain common tower mounted amplifiers.
A-ETMA corresponds to the AISG tower mounted amplifier with high
gain.

No change

Uplink gain of the tower mounted amplifier (TMA).


The unit for different TMA types: A-TMA: 0.25dB, A-COM: 0.5dB,
TMA: 0.1dB, ETMA: 0.1dB, A-ETMA: 0.25dB.

No change

Downlink gain of the tower mounted amplifier (TMA).


Unit: 0.1dB.

No change

TMA noise coefficient.


Unit: 0.1dB.

No change

Downlink delay of the tower mounted amplifier (TMA).

No change

Uplink delay of the tower mounted amplifier (TMA).

No change

RDN

No change

User-oriented description of the object.


Name of the intelligent antenna vendor.
Antenna type
Intelligent antenna gain
Antenna interval (for line array) or radius (for circle array).
Specify number of antenna array units.
Type of the antenna.
RDN

No change
No change
No change
Modified
Modified
No change
No change
No change

User-oriented description of the object.


Used antenna attribute.
Coverage scenario.

No change
No change
No change
No change

RET device type connected with the antenna entity.

No change

The antenna orientation of circle array is the offset angle of the 0th
No change
antenna from the north direction. The antenna orientation of line array
is the offset angle of the sector transmission direction from the north
direction.

Indicates whether the geographical information is valid.

No change

Valid when geographical information is valid.

No change

Valid when geographical information is valid.


Valid when geographical information is valid.
Valid when geographical information is valid.

No change
No change
No change

Valid when geographical information is valid.


Valid when geographical information is valid.
Valid when geographical information is valid.
Valid when geographical information is valid.

No change
No change
Added
No change

The user identification.


The value of RET pitch angle.
The value of maximum pitch angle.
The value of minimum pitch angle.
Mechnical offset
RET group name
Maximum azimuth.
Minimum azimuth.
Indicate beam width of 3dB antenna on the horizontal plane.

No change
No change
No change
No change
No change
No change
No change
No change
No change

Indicate beam width of 3dB antenna on the vertical plane.

No change

Indicate space diversity.


Indicate diversity type.
Pattern label
Cell list.
RDN

No change
No change
No change
No change
No change

User-oriented description of the object.


The Ir antenna group ID.
Used antenna.
The RRU to which local IR antenna group belongs.
Specify object ID of RF cable.

No change
No change
No change
No change
No change

User-oriented description of the object.


Downlink attenuation of the RF cable.
Uplink attenuation of the RF cable. When the RF cable is used to
connect the remote unit to the tower mounted amplifier, the default
value is 0.5dB. In other cases, the default value is 0dB.

No change
No change
No change

Downlink delay of the RF cable.

No change

Uplink delay of the RF cable.

No change

The antenna connected with the RF cable.

No change

The tower mounted amplifier (TMA) connected with the RF cable.

No change

The RF port connected with the RF cable. It is the radio frequency


port of RU.

No change

RDN

No change

User-oriented description of the object.


Downlink attenuation of the RF cable.
Uplink attenuation of the RF cable. The default value is 0dB.

No change
No change
No change

Downlink delay of the RF cable.

No change

Uplink delay of the RF cable.

No change

Main RU.

No change

Extended RU.

No change

RDN

No change

User-oriented description of the object.


The upper level port for cable cascading connection.

No change
No change

The lower level port for cable cascading connection.

No change

RDN

No change

User-oriented description of the object.

No change

RDN

No change

User-oriented description of the object.


Physical layer port number is used to uniquely identify the physical
layer resource. Can customize it within its value range.

No change
No change

Configure the physical medium used by physical layer port.

No change

The opposite NE connection with the object. In base station


No change
cascading, it is set to SDE for upper level. If it is set to Third party
device, in the case of ATM+FE cascading, local base station provides
data transmission channel for third-party devices.
E1 bearer used by the port. It is used in ATM transmission mode or IP No change
over PPP transmission mode.

T1 bearer used by the port. It is used in ATM transmission mode or IP No change


over PPP transmission mode.

Ethernet used by the port. It is used in IP transmission mode.

No change

The configuration of transmission media. It is used in ATM


transmission mode.

No change

When Ethernet IP transmission mode is used on physical layer port,


Working mode and Transmitting bandwidth need to be configured.

No change

Indicate the backup Ethernet port ID and IP transmission mode. 0, 2, No change


4, 6 represent Iub/Abis port. Do not need to configure this parameter
on CCC board.
Indicate the working mode of backup Ethernet port.

No change

Indicate the Ethernet port priority.

No change

RDN

No change

User-oriented description of the object.


Unique identification of TC and IMA, customized by the user.
Object protocol type represented by local MO. It must be consistent
on the opposite end.

No change
No change
No change

Indicates whether to enable descrambling. It is the IMA protocol


parameter indicating whether to descramble cell net load. The
configuration must be consistent on the opposite end device.

No change

IMA group number, unique within a network element.

No change

Frame length of IMA group. It must be consistent on the opposite


end.

No change

Clock mode of IMA group. It is recommended to be consistent on the No change


opposite end.
E1 or T1 time slot used by TC. Each bit within the value range
represents a time slot. 0 indicates the time slot is not used. 1
indicates the time slot is used. For E1, time slot 1-31 can be
configured. For T1, time slot 1-24 can be configured.

No change

It is valid when ATM layer protocol is IMA and TC. The transmission
media used by physical layer port must be E1, T1, or STM-1. Only
one physical layer port is used when ATM layer protocol is TC.

No change

Configure this parameter when channelized STM-1 is used. Only one No change
channelized STM-1 is used when ATM layer protocol is TC.
RDN

No change

User-oriented description of the object.


No change
PVC number of AAL2. It must begin from 1 and must be consecutive. No change
Input by the user.

Path ID of the AAL2 link. It must begin from 1. It is customized by the No change
user, and must be consistent with the configuration on the opposite
end. If the configuration is incorrect, the public transmission channel
cannot be established and UE cannot be accessed.

VPI of the AAL2 link. It must be consistent with the configuration on


the opposite end. Or else the public transmission channel cannot be
established and UE cannot be accessed.

No change

VCI of the AAL2 link. It must be consistent with the configuration on


the opposite end. Or else the public transmission channel cannot be
established and UE cannot be accessed.

No change

ATM flow attribute configuration, including the maximum transmitting


bandwidth and the minimum transmitting bandwidth.

No change

Link that bears AAL2.

No change

RDN

No change

User-oriented description of the object.


AAL5 PVC link number.

No change
No change

VPI of the AAL5 link. It must be consistent with the configuration on


the opposite end.

No change

VCI of the AAL2 link. It must be consistent with the configuration on


the opposite end.

No change

AAL5 flow attribute configuration, including the maximum transmitting No change


bandwidth and the minimum transmitting bandwidth.
Link that bears AAL5.

No change

RDN

No change

User-oriented description of the object.

No change

AAL5 link that bears ALCAP.

No change

RDN

No change

User-oriented description of the object.


No change
Base station cascading type. It indicates how a base station transmits No change
data to the lower-level base station. It is irrelevant to the high-layer
data protocol. Time slot cross means mapping from the time slots of
input E1/T1 to the time slots of output E1/T1 within the base station.
ATM routing means local base station forwards the input foreign PVC
according to the configured routing.
Indicate the time slot cross link ID in TSI cascading mode. Indicate
the routing number in ATM cascading mode.

No change

In TSI cascading mode, represents the E1/T1 for upper-level base


station to connect with RNC/BSC/CN (ingress E1 or T1).

No change

Describes which time slots in the inlet E1/T1 are reserved for the
lower-level base station. Each bit corresponds to one time slot. 0
indicates not reserved for the lower-level base station. 1 indicates
reserved for the lower-level base station.

No change

In TSI cascading mode, represents the E1/T1 for upper-level base


station to connect with SDR (outlet E1 or T1).

No change

Describes which time slots in the outlet E1/T1 are reserved for the
lower-level base station. Each bit corresponds to one time slot. 0
indicates not reserved for the lower-level base station. 1 indicates
reserved for the lower-level base station. It must be one-one
corresponding to the lower-level time slots.

No change

Ingress VPI of the ATM route. It must be consistent with the


RNC/BSC/CN configuration.

No change

Ingress VCI of the ATM routing. It must be consistent with the


RNC/BSC/CN configuration.

No change

Ingress PVC low-layer link of the ATM routing. It can only be IMA or
TC, and must be consistent with the RNC/BSC/CN configuration

No change

Egress VPI of the ATM route. It must be consistent with the lowerlevel SDR configuration.

No change

Egress VCI of the ATM route. It must be consistent with the lowerlevel SDR configuration.

No change

Egress PVC infrastructure link of the ATM routing. It can only be


either IMA or TC. It must be consistent with the RNC/BSC/CN
configuration.

No change

ATM flow attribute configuration, including the maximum transmitting


bandwidth and the minimum transmitting bandwidth.

No change

Destination base station ID. It is used in early versions and does not
take effect currently. Configuration is not required.

No change

In LACP cascading mode, represents the LACP group for upper-level No change
base station to connect with RNC/BSC/CN.
In LACP cascading mode, represents the LACP group for lower-level No change
base station to connect with SDR.
RDN

No change

User-oriented description of the object.


HDLC link number. The range is customized by the user.

No change
No change

E1 or T1 time slot used by TC. Each bit represents a time slot. 0


indicates the time slot is not used. 1 indicates the time slot is used.

No change

Physical layer port which bears HDLC.

No change

RDN

No change

User-oriented description of the object.

No change

PPP link number. The range is customized by the user.

No change

IP address of the base station. It is used for signaling and service


data transmission in the IP network. 0.0.0.0 indicates obtaining the
local IP address by negotiating with NE on the opposite end.

No change

PPP encapsulation type. It must be consistent on the opposite end.

No change

Long/short sequence format of the ML-PPP packet header. If it is


No change
different from on the opposite end, ML-PPP will automatically perform
negotiation.

Indicates the number of supported priorities when ML-MC PPP is


supported (When MC is supported, two bits in the frame format are
used to represent the priority).

No change

The time interval of sending the Echo-Request message.

No change

Indicates whether the ML-PPP link supports the IP compression


mode. If it is different on the opposite end, ML-PPP automatically
performs negotiation.

No change

Indicates whether the PPP link is used for cascading. The cascading
mode is E1/T1+Ethernet.

No change

Maximun slicing size when MLPPP is segmented.

No change

No change

Relative Distinguished Name (RDN).

No change

User-oriented description of the object.

No change

No change
No change
No change

Indicate physical layer port of Ethernet.


Relative Distinguished Name (RDN).
User-oriented description of the object.

No change
No change
No change
No change
No change
No change

No change

RDN

No change
No change

User-oriented description of the object.


No change
Ethernet link number. One Ethernet physical port corresponds to one No change
link.
Represents the maximum transmitted bytes of each Ethernet link
layer packet. Larger value indicates higher bandwidth usage.
However, it might cause the end-to-end transmission delay to
increase. It can be adjusted according to the actual on-site situation
to avoid the data packet being segmented in transmission.

No change

VLAN number contained in the Ethernet frame. It is optional and a


maximum of 30 numbers can be configured.

No change

Physical layer port which bears Ethernet.

No change

LACP Aggregation Port which bears Ethernet.

No change

RDN

No change

User-oriented description of the object.


EthernetOam mode. Only the NE in the active mode can initiate the
OAM connection.

No change
No change

It is used to configure the timeout period of the OAM session. When


the period expires, the link is considered to be broken.

No change

It is used to configure the EthOam packet transmission period (unit:


100 ms). The protocol specifies that the number of packets
transmitted per second is 1-10.

No change

Information related to error frame and error symbol.

No change

Configuration information of the IP port that bears VLAN. The


transmission medium must be Ethernet.

No change

RDN

No change

User-oriented description of the object.


DHCP relay number. Can be customized within the value range.

No change
No change

Used IP layer configuration.


Whether the DHCP relay function is enabled.

No change
No change

IP address of DHCP server. Do not support IPv6.


Specify object ID of bandwidth resource group.

No change
No change

User-oriented description of the object.


No change
Specify the bandwidth resource group number, which must be unique No change
in the same bearer mode. In the Ethernet bearer mode, the number
can be set to 0-7.
Indicate on which Ethernet link the bandwidth allocation rule is
applied. It is mutually exclusive with refPppLink.

No change

Indicate maximum available bandwidth of egress.

No change

Specify object ID of bandwidth resource.

No change

User-oriented description of the object.


Specify bandwidth resource number.
Configure transmission bandwidth weight.

No change
No change
No change

RDN

No change

User-oriented description of the object.


Configure QoS queue number of IP bandwidth resource. The QoS
queue number of the same IP bandwidth resource must be unique.

No change
No change

This attribute indicates differential services code point, corresponding No change


to the DSCP field in IP packets.
RDN

No change

User-oriented description of the object.


IP configuration ID. Can be customized within the value range.

No change
No change

PPP link that bears IP.

No change

Ethernet link that bears IP.

No change

Same as a VLAN in refEthernetLink.

No change

IP address of the base station. When the PPP link is used, the IP
No change
address information cannot be configured. It can be IPv4 address or
IPv6 address. The IPv4 address format is dotted decimal format, i.e.
10.0.0.1, IPv6 address is colon hexadecimal format, i.e.
2011:0db8:85a3:0000:1319:8a2e:0370:7366. It cannot be configured
with the IP address of the 192.254 network segment, the 127 network
segment and the 200 network segment.
Gateway. It can be IPv4 address or IPv6 address. The IPv4 address No change
format is dotted decimal format, i.e. 10.0.0.1, IPv6 address is colon
hexadecimal format, i.e. 2011:0db8:85a3:0000:1319:8a2e:0370:7366.

Subnet mask. Only IPv4 address can be configured.

No change

Prefix length configuration. Only IPv6 address can be configured.

No change

The information of the domain which IP address belongs to. 0XFF


indicates that it does not belong to any domain.

Modified

Valid when local IP address is used for LTE transmission. It is used


for the LTE X2 self-establishment.

No change

Valid when local IP address is used for LTE transmission. It is used


for the LTE X2 self-establishment.

No change

Specify object ID of DSCP to COS mapping.

No change

User-oriented description of the object.


Configuration of IP layer that bears SCTP association.

No change
No change

Indicate differential services code point, corresponding to the DSCP


field in IP packet.

No change

Indicate service class, corresponding to the COS field in Ethernet


802.1q frame.

No change

Specify object ID of service and DSCP mapping.

No change

User-oriented description of the object.


No change
Configure the IP parameter of bearer services.
No change
Configure the bandwidth resource of bearer services. This parameter No change
must be configured if the bandwidth is configured.
Mapping rule between LTE FDD service and DSCP. It indicates with
which QoS priority the IP layer bears the corresponding service. If
DSCP is set to 0xFF, it indicates that this IP layer does not bear the
corresponding service.

No change

Mapping rule between TD-LTE service and DSCP. It indicates with


which QoS priority the IP layer bears the corresponding service. If
DSCP is set to 0xFF, it indicates that this IP layer does not bear the
corresponding service.

No change

Indicate for which operator the bandwidth rule is allocated. If it is not


set, bandwidth control is not implemented between operators.

No change

Specify object ID of static routing configuration.

No change

User-oriented description of the object.


The unique ID of static routing. It cannot be duplicated.

No change
No change

The destination network address of static routing. It can be IPv4 or


No change
IPv6 address. The IPv4 format is decimal separated by dots, such as
10.0.0.1. The IPv6 address is hexadecimal separated by colon, such
as 2011:0db8:85a3:0000:1319:8a2e:0370:7366.

The gateway address configuration of next hop. It can be IPv4 or IPv6 No change
address. The IPv4 format is decimal separated by dots, such as
10.0.0.1. The IPv6 address is hexadecimal separated by colon, such
as 2011:0db8:85a3:0000:1319:8a2e:0370:7366.

The destination network mask of static routing.

No change

The prefix length configuration. Configured only for IPv6


addresses.

No change

The routing distance configuration. Configured only for IPv6


addresses.

No change

The priority of IP routing. 0 indicates the highest priority.

No change

Ethernet link that bears IP.


It is the same as a certain VLAN in refEthernetLink.
RDN

No change
No change
No change

User-oriented description of the object.


Routing detection object number.
Indicates the destination address.
Routing detection mode, use ICMP or ARP protocol.

No change
No change
No change
No change

Period of routing detection.


Timeout period must less than or equal to detection period.
The maximum lost packets allowed.
Used IP layer configuration.

No change
No change
No change
No change

RDN

No change

User-oriented description of the object.

No change

IKE policy number.

No change

IKE policy priority.

No change

IKE version.

No change

IKE negotiation encryption algorithm.

No change

Hash algorithm.

No change

Random number function algorithm.

No change

DH group.

No change

IKE SA lifetime.

No change

Used IPSec Global Configuration Object

No change

User-oriented description of the object.

No change

IPSec proposal number.

No change

IPSec mode.

No change

ESP authentication algorithm.

No change

ESP encryption algorithm.

No change

IPSec Security Policy Database Object ID

No change

User-oriented description of the object.

No change

IPSec security policy group number.

No change

IPSec security policy configuration.


Relative Distinguished Name (RDN).

No change
No change

User-oriented description of the object.


XAUTH user name.
XAUTH password.
Relative Distinguished Name (RDN).

No change
No change
No change
No change

User-oriented description of the object.

No change

Configure whether the NAT traversal is supported.

No change

Configure transmission interval of NAT keep-alive message.

No change

RDN

No change

User-oriented description of the object.

No change

IPSec configuration number.

No change

IKE negotiation authentication method.

No change

Negotiate entity ID load type: RFC2408 and RFC4306.

No change

IKE version.

No change

Remote IP address.

No change

PFS value when IPSec is at the second stage.

No change

IPSec policy generation method.

No change

SA byte lifetime. 0 is a valid value indicating the parameter is


disabled.

No change

SA lifetime. 0 is a valid value indicating the parameter is disabled.

No change

Pre-shared key.
No change
Dead Peer Detection (DPD) is based on the ISAKMP to exchange
No change
information and provides a method to detect whether the peer end is
disabled. If a peer end fails to respond within a certain time period, all
associated SAs are normally considered to be disabled.
Host domain name (FQDN)

No change

Used XAUTH configuration.


Used IP layer configuration.

No change
No change

Used IPSec proposal.


Used IPSec Security Policy Database Object

No change
No change

Used IPSec Global Configuration Object

No change

RDN

No change

User-oriented description of the object.

No change

Access control rule number.


Local IP address filtered by ACL.

No change
No change

Local IPv4 mask.

No change

Remote IP address filtered by ACL.

No change

Remote IPv4 mask.

No change

Start value of filtered range for local port number.

No change

End value of filtered range for local port number.

No change

Start value of filtered range for remote port number.

No change

End value of filtered range for remote port number.

No change

Filter protocol number corresponding to ACL rule.

No change

Configuration of ACL filtering direction.

No change

The action executed by filtering ACL.

No change

No change

No change

No change

No change

Used IP layer configuration.


RDN

No change
No change
No change
No change

User-oriented description of the object.


Application layer protocol which is used for CMP message
transmission.

No change
No change

Used IP layer configuration.


Specify the CA server type. At present, open source EJBCA and
commercial RCM servers can be used.

No change
No change

IP address of CA server.
No change
The server side URL of CMP protocol (the remaining part with host
No change
address and port removed) is entered according to the CMP protocol
configuration of CA server.
Used to fill in the application subject (subject field value) of base
station certificate. The writing format should meet the X.500
Standard. For example, C=CN,O=ZTE,CN=Nodeb01.

No change

Used to fill in the application subject (subject field value) of base


station certificate's issuer. The writing format should meet the X.500
Standard. For example, C=CN,O=ZTE,CN=Nodeb01.

No change

Used to fill in the extended option of certificate application. The


writing format is 'attribute name=attribute value;'.

No change

Transport layer port number of CA server. It should be entered


according to the actual CA server configuration.

No change

The generated private key length. It can be 1024 or 2048 and the unit No change
is bit.
Used to enter CerRequest information of CMP protocol according to
CA/RA strategy.

No change

RDN

No change

User-oriented description of the object.

No change

SCTP association link number. Can be customized within the value


range.

No change

Local port number of SCTP association link. It is the interconnection


parameter.

No change

Configuration of IP layer that bears SCTP association.

No change

Configure the bandwidth resource.


Remote port number of SCTP association link. It is the
interconnection parameter.

No change
No change

Remote IP address of SCTP association link. It is the interconnection No change


parameter. It can be IPv4 or IPv6 address. The IPv4 address format
is dotted decimal format, i.e. 10.0.0.1, IPv6 address is colon
hexadecimal format, i.e. 2011:0db8:85a3:0000:1319:8a2e:0370:7366.
Corresponds to the four IP addresses in association. One of the four
IP addresses is selected as the preferred path.

No change

Number of incoming and outgoing streams of SCTP association. A


maximum of six incoming and outgoing streams can be configured.

No change

IP service model configuration. Different models are chosen


according to the actual scenario.

No change

After the SCTP link-establishment timed out, the maximum


retransmission times of the INIT message.

No change

After sending the DATA message timed out on a single path of SCTP, No change
the maximum retransmission times on the single path of SCTP.
After sending the DATA message timed out on a SCTP link, the
maximum retransmission times on the SCTP link.

No change

After sending the DATA and HEARTBEAT messages timed out, the
minimum time interval of retransmission.

No change

After sending the DATA and HEARTBEAT messages timed out, the
maximum time interval of retransmission.

No change

The time interval of sending the HEARTBEAT message.

No change

SCTP coupling used in which radio standard, such as GSM or UMTS. No change

RDN

No change

User-oriented description of the object.


MD number. It begins from 0 and must be unique.
MD index number. It begins from 1, in ascending order, and must be
unique.

No change
No change
No change

An Ethernet port that belongs to local MD on the local base station.


Currently only the Iub/Abis interface on CC board can be used.

No change

MD level.
MD name. The ending character of the attribute must be printable
ASCII code. No space is allowed at the beginning or end.

No change
No change

RDN

No change

User-oriented description of the object.


MA number. It begins from 0 and must be unique.
MA index number. It begins from 1, in ascending order, and must be
unique.

No change
No change
No change

IP link used by MA.


VLAN used by MA. Currently one MA only supports one VLAN.
MA name. The ending character of the attribute must be printable
ASCII code. No space is allowed at the beginning or end.

No change
No change
No change

CCM detection period. If the CCM message from the opposite end is
not received after 3.5 times of the period, the link is considered to be
abnormal.

No change

RDN

No change

User-oriented description of the object.


MP number. It begins from 0 and must be unique.
MP index number. It begins from 1, in ascending order, and must be
unique.

No change
No change
No change

MEP number (MEPId). It is customized by the user, and must be


unique within the MA range.

No change

MEP type.

No change

Configure local MEP detailed parameters. It is valid when MPE type


is set to Local MEP.

No change

Configure remote MEP detailed parameters. It is valid when MPE


type is set to Remote MEP.

No change

Indicates whether to enable CCM detection. If MEP type is Local


No change
MEP, enabling the CCM detection means that the multicast CCM
detection is executed on local end. If MEP type is Remote MEP,
enabling the CCM detection means that the unicast CCM detection is
executed on remote end. The current version only supports multicast
CCM detection.
Represents the UDP object.

No change

User-oriented description of the object.

No change

Used IP layer configuration.

No change

RDN

No change

User-oriented description of the object.


Bidirectional forwarding detection link number. Can be customized
within the value range.

No change
No change

Remote IP address and local IP address form an IP path that can be


detected by BFD. Do not support IPv6.

No change

BFD packet service quality priority. Can be customized within the


value range. It is recommended to set it to 46.

No change

The detection mode is multi-hop detection or single-hop detection.


For direct connection, set it to N (single-hop detection). If there are
other switching devices in the connection, set it to Y (multi-hop
detection).
If the BFD detection mode is multi-hop detection, only one multi-hop
BFD can be configured for one IP address.
If and only if the BFD detection mode is single-hop detection, the
local IP address and the remote IP address must be within the same
network segment.

No change

Configure minimum interval of transmitting packets expected by local No change


end. The value is determined by the negotiation of both ends. If the
value is changed, BFD session will be negotiated again.

Configure minimum interval of receiving packets supported by local


end. The value is determined by the negotiation of both ends. If the
value is changed, BFD session will be negotiated again.

No change

Configure the detection time accumulator of BFD session. If the value No change
is changed, BFD session will be negotiated again.
UDP link that bears BFD.

No change

Configuration related to BFD authentication.


RDN

No change
No change

User-oriented description of the object.


Indicate the 1588 clock device type adopted by BS.

No change
No change

Indicate the 1588 link mode adopted by BS.

No change

1588 clock packet transmission way.

No change

RDN

No change

User-oriented description of the object.

No change

IP clock link priority.


PTP network protocol.

No change
No change

1588 clock message transmission mode.

No change

IP address of 1588 clock synchronization server.

No change

1588 clock packet service quality priority. Can be customized within


the value range. It is recommended to set it to 46.

No change

PTP port mode.

No change

Indicates whether to enable link setup by negotiation.

No change

The multicast type of IPv6 indicates the multicast is one of the


No change
following types: link domain, admin domain, site domain, organization
domain, and global domain.

Ethernet link that bears IP.

No change

Same as a VLAN in used ethernet link.

No change

UDP link that bears 1588 clock.

No change

Configure the bandwidth resource.


Relative Distinguished Name (RDN).

No change
No change

Indicate user-oriented description of the object.


No change
Specify KPI measurement number. The number for the measurement No change
object of the same type must be unique.
Indicate local IP address.
Indicate remote IP address.
Indicate VLAN ID.
Indicate DSCP.
RDN

No change
No change
No change
No change
No change

User-oriented description of the object.


Itf-UniBTS channel number. Can be customized within the value
range.

No change
No change

Itf-UniBTS packet encapsulation type, IPINIP, IPOA (used in the ATM No change
mode) or IP (independent networking).
The O&M packet can use IPINIP or IPOA mode through RNC/BSC
resolution transferring.
The O&M packet can use the independent networking mode without
RNC/BSC resolution.
The inner IP address of base station configured in the IPINIP mode. It No change
is used for OMC and it is an interconnection parameter
(interconnected with OMC).

The IP address of OMC gateway configured in the IPINIP mode. The No change
O&M packet is forwarded to the OMC server through the gateway (in
RNC/BSC). It can be IPv4 address or IPv6 address. The IPv4
address format is dotted decimal format, i.e. 10.0.0.1, IPv6 address is
colon hexadecimal format, i.e.
2011:0db8:85a3:0000:1319:8a2e:0370:7366.
IP address of the OMC server configured in the independent
networking mode.

No change

Subnet mask of the OMC server configured in the independent


networking mode.

No change

The transmission quality priority of O&M packet. It is customized by


the user. It is recommended to set it to '46:EF service, accelerated
forwarding, minimum delay, and maximum flow'.

No change

IP address in the IPOA transmission mode. It is customized by the


No change
user, and it is an interconnection parameter. 0.0.0.0 indicates that the
IP address is obtained automatically.
Subnet mask of the OMC server configured in the independent
networking mode.
Only IPv6 omcServerIP address can be configured.

No change

Used IP layer configuration.

No change

AAL5 link used in the IPOA mode.

No change

Configure the bandwidth resource.


RDN
User-oriented description of the object.
Operator name.

No change
No change
No change
No change

Customized information.

No change

RDN
User-oriented description of the object.
The Mobile Country Code of a PLMN identity used in the radio
network.

No change
No change
No change

The Mobile Network Code of a PLMN identity used in the radio


network.

No change

RDN
No change
User-oriented description of the object.
No change
The reset time of base station self-recovery function, which indicates No change
when the broken duration of the transmission layer control link (SCTP,
SSCOP), LMT O&M channel, and OMC O&M channel exceed the
parameter, automatic reset is executed on the base station to solve
the broken link problem which might be caused by hardware fault.
Indicates whether to enable Bypass switch. Bypass means in daisy
No change
chain condition, previous-level BBU provides auto-bridging function to
transfer the E1 connected with BSC/RNC to the next-level BBU when
the previous-level BBU is powered down or abnormal. In this way the
effect range of the fault is smaller.
Indicates whether to enable SLA switch.

No change

Indicates whether to Forbid FTP switch.

No change

Indicates whether to Forbid TELNET switch.

No change

RDN

No change

User-oriented description of the object.


RRU channel power saving switch.

No change
No change

Start time of RRU power saving.

No change

End time of RRU power saving.

No change

Power amplifier power saving switch

No change

Indicate RSSI report period.

No change

RDN

No change

User-oriented description of the object.


Antenna calibration period.
The start time of periodical antenna calibration. Unit: minute.
Amplitude difference threshold of antenna calibration channel
wAcAmpDiffThres,10-80 (default value 30, step value 1
corresponding to 1.0-8.0db. Step is 0.1 db. Unit is 0.1 db).

No change
No change
No change
No change

Amplitude difference threshold of antenna calibration process


wAcSubFnAmpDiffThre, 5-60 (default value 30, step value 1
corresponding to 0.5-6.0db. Unit is 0.1 db).

No change

Angle difference threshold of antenna calibration process


wAcSubFnAngleDiffThres, 0-360 (default value 5, step value 1).

No change

RDN

No change

User-oriented description of the object.


Related parameter configuration for hardware auto-discovery.

No change
No change

Related parameter configuration for auto-commissioning.

No change

Related parameter configuration for auto-setup transmission.

No change

Configure related parameters for data rollback.

No change

Indicate the OSPF instance ID.

No change

User-oriented description of the object.


Uniquely identify a router, represented in the form of IP address.
Indicate SPF calculation time interval.
Indicate whether the RFC1583 rule is compatible.

No change
No change
No change
No change

Indicate OSPF area sequence number.

No change

User-oriented description of the object.


Indicate OSPF area number, represented in the form of IP address.
Specify object ID of OSPF stub settings.

No change
No change
No change

User-oriented description of the object.


Indicate sequence number of OSPF interface.

No change
No change

User-oriented description of the object.


Indicate the OSPF interface number.
Indicate cost.
Indicate interval for sending Hello message.
Check whether neighbor in the Up status, If no response within the
dead time from the neighbor, regarding the neighbor in the Down
status.

No change
No change
No change
No change
No change

Set interface priority. If the priority is set to 0, it indicates that the


interface cannot be elected as DR or BDR.

No change

The local IP link number. It is corresponding to the ipNo attribute of


IpLayerConfig object.

No change

RDN

No change

User-oriented description of the object.


No change
A timer used by the Supplicant PAE to determine how long to wait for No change
a request from the Authenticator before timing it out.
A timer used by the Supplicant PAE state machine to determine when No change
an EAPOL-Start PDU is to be transmitted.
A timer used by the Supplicant state machine to define periods of
time during which it will not attempt to acquire an Authenticator.

No change

The maximum times of successful EAPOL-Start message


transmission before the client ensure that there is no authentication
end.

No change

User ID.
User password.
Ethernet link that bears IP.

No change
No change
No change

It is the same with a certain VALN of used Ethernet link.

No change

Modified

ZTE

Table Name
Configuration of ATM
Throughput Poroperty

Configuration of AAL5
Throughput Poroperty

Parameter Name

Short Name

Maximum Transmitting Bandwidth maxEgressBitRate

Average Transmitting Bandwidth

averageEgressBitRate

Minimum Transmitting Bandwidth

minEgressBitRate

Maximum Receiving Bandwidth

maxIngressBitRate

Average Receiving Bandwidth

averageIngressBitRate

Minimum Receiving Bandwidth

minIngressBitRate

Service Type

serviceCategory

Maximum Transmitting Bandwidth maxEgressBitRate

Average Transmitting Bandwidth

averageEgressBitRate

Minimum Transmitting Bandwidth

minEgressBitRate

Maximum Receiving Bandwidth

maxIngressBitRate

Average Receiving Bandwidth

averageIngressBitRate

Minimum Receiving Bandwidth

minIngressBitRate

<>

302 , 231

ZTE

Product Information

Local MEP Parameter

Remote MEP Parameter

BFD Authority Parameter

Information of event type

Service Type

serviceCategory

Product name

productName

Product number

productNumber

Local MEP Level

localLevel

the Lowest Alarm Level

alarmLowestLevel

Related Local MP Index

localMPIndex

MAC of Remote MEP

remoteMEPMacAddr

Authentication type

authorityType

Authentication key ID

authorityKeyId

Authentication key

authorityKeyValue

Event Type

eventType

Window Size

windowSize

<>

302 , 232

ZTE
Threshold

threshold

IPSec Security Policy Index

spIndex

Source address
Source address subnet mask
Destination address
Destination address subnet mask

sourceIp
sourceSubnetMask
destinationIp
destinationSubnetMask

Maximum rule of protocol code


Minimum rule of protocol code
Maximum source port
Minimum source port
Maximum destination port
Minimum destination port
Rule action

ruleMaxProtocol
ruleMinProtocol
maxSourcePort
minSourcePort
maxDestinationPort
minDestinationPort
ruleAction

Configuration for hardware


auto-discovery

Function switch

functionSwitch

Configuration for site autoopening

Auto-opening switch

functionSwitch

Operating mode

operatingMode

Automatic chain-establishment
switch

functionSwitch

Automatic chain-establishment
mode

autoConnectionMode

Tolerant time of first time link


broken

firstBrokenTolerantTime

IPSec Security Policy


Configuration

Configuration for Auto-setup


Transmission Link

<>

302 , 233

ZTE

Mapping relation from LTE


service type to DSCP at IP
layer

Tolerant time of next time link


broken

nextBrokenTolerantTime

Transmission priority 1 of LTE


service

serviceDscp1

Transmission priority 2 of LTE


service

serviceDscp2

Transmission priority 3 of LTE


service

serviceDscp3

Transmission priority 4 of LTE


service

serviceDscp4

Transmission priority 5 of LTE


service

serviceDscp5

Transmission priority 6 of LTE


service

serviceDscp6

Transmission priority 7 of LTE


service

serviceDscp7

Transmission priority 8 of LTE


service

serviceDscp8

Transmission priority 9 of LTE


service

serviceDscp9

Transmission priority 10 of LTE


service

serviceDscp10

Transmission priority 11 of LTE


service

serviceDscp11

Transmission priority 12 of LTE


service

serviceDscp12

<>

302 , 234

ZTE
Transmission priority 13 of LTE
service

serviceDscp13

Transmission priority 14 of LTE


service

serviceDscp14

Transmission priority 15 of LTE


service

serviceDscp15

Transmission priority 16 of LTE


service

serviceDscp16

Transmission priority 17 of LTE


service

serviceDscp17

Transmission priority 18 of LTE


service

serviceDscp18

Transmission priority 19 of LTE


service

serviceDscp19

Transmission priority 20 of LTE


service

serviceDscp20

Transmission priority 21 of LTE


service

serviceDscp21

Transmission priority 22 of LTE


service

serviceDscp22

Transmission priority 23 of LTE


service

serviceDscp23

Transmission priority 24 of LTE


service

serviceDscp24

Transmission priority 25 of LTE


service

serviceDscp25

Transmission priority 26 of LTE


service

serviceDscp26

<>

302 , 235

ZTE
Transmission priority 27 of LTE
service

serviceDscp27

Transmission priority 28 of LTE


service

serviceDscp28

Transmission priority 29 of LTE


service

serviceDscp29

Transmission priority 30 of LTE


service

serviceDscp30

Transmission priority 31 of LTE


service

serviceDscp31

Transmission priority 32 of LTE


service

serviceDscp32

Transmission priority 33 of LTE


service

serviceDscp33

Transmission priority 34 of LTE


service

serviceDscp34

Transmission priority 35 of LTE


service

serviceDscp35

Transmission priority 36 of LTE


service

serviceDscp36

Transmission priority 37 of LTE


service

serviceDscp37

Transmission priority 38 of LTE


service

serviceDscp38

Transmission priority 39 of LTE


service

serviceDscp39

Transmission priority 40 of LTE


service

serviceDscp40

<>

302 , 236

ZTE
Transmission priority 41 of LTE
service

serviceDscp41

Transmission priority 42 of LTE


service

serviceDscp42

Transmission priority 43 of LTE


service

serviceDscp43

Transmission priority 44 of LTE


service

serviceDscp44

Transmission priority 45 of LTE


service

serviceDscp45

Transmission priority 46 of LTE


service

serviceDscp46

Transmission priority 47 of LTE


service

serviceDscp47

Transmission priority 48 of LTE


service

serviceDscp48

Transmission priority 49 of LTE


service

serviceDscp49

Transmission priority 50 of LTE


service

serviceDscp50

Transmission priority 51 of LTE


service

serviceDscp51

Transmission priority 52 of LTE


service

serviceDscp52

Transmission priority 53 of LTE


service

serviceDscp53

Transmission priority 54 of LTE


service

serviceDscp54

<>

302 , 237

ZTE

Ethernet configuration
parameter

Configuration Recovery

Transmission priority 55 of LTE


service

serviceDscp55

Transmission priority 56 of LTE


service

serviceDscp56

Transmission priority 57 of LTE


service

serviceDscp57

Transmission priority 58 of LTE


service

serviceDscp58

Transmission priority 59 of LTE


service

serviceDscp59

Transmission priority 60 of LTE


service

serviceDscp60

Transmission priority 61 of LTE


service

serviceDscp61

Transmission priority 62 of LTE


service

serviceDscp62

Transmission priority 63 of LTE


service

serviceDscp63

Transmission priority 64 of LTE


service

serviceDscp64

Working mode

operatingMode

Transmitting bandwidth

egressPeakBitRate

Configuration for rollback switch

functionSwitch

<>

302 , 238

ZTE
Tolerance duration of the first link
broken

brokenTolerantTime

<>

302 , 239

ZTE

Parameter Format

Range and Step

Default Value

long

[0..30000]

2048

long

[0..30000]

2048

long

[0..30000]

2048

long

[0..30000]

2048

long

[0..30000]

2048

long

[0..30000]

2048

long

SRVC_CBR,
SRVC_RTVBR,
SRVC_NRTVBR,
SRVC_UBR,
SRVC_ABR,
SRVC_OTHER

SRVC_CBR

long

[0.1500]

128

long

[0..1500]

128

long

[0.1500]

128

long

[0..1500]

128

long

[0..1500]

128

long

[0..1500]

128

<>

302 , 240

ZTE
long

SRVC_CBR,
SRVC_RTVBR,
SRVC_NRTVBR,
SRVC_UBR,
SRVC_ABR,
SRVC_OTHER

SRVC_CBR

string

[1..201]

N/A

long

[0..65535]

long

[0..7]

long

[1..5]

long

[1..32]

long

Not support authentication,


Simple Password,
Keyed MD5,
Meticulous Keyed MD5,
Keyed SHA1,
Meticulous Keyed SHA1

Simple Password

long

[1..255]

string

N/A

0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0

long

Errored frame second link event,


Errored frame period link event,
Errored frame link event,
Errored symbol period link event

long

Errored frame second link event:


[10..900],
Errored frame period link event:
[1..600],
Errored frame link event, :
[1..60],
Errored symbol period link event:
[1..65535]

string

Errored frame second link event: [60],


Errored frame period link event: [600],
Errored frame link event: [1],
Errored symbol period link event: [1]

<>

302 , 241

ZTE
unsigned long

Errored frame second link event:


[1..900],
Errored frame period link event:
[1..65535],
Errored frame link event, :
[1..65535],
Errored symbol period link event:
[1..0xFFFFFFFF]

unsigned long

[1..48]

string
string
string
string

0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0

long
long
long
long
long
long
long

[0..255]
[0..255]
[0..65535]
[0..65535]
[0..65535]
[0..65535]
bypass,
discard,
protect

255
0
65535
0
65535
0
protect

long

Close,
Open

Close

long

Close,
Open

Close

long

Autonomous mode,
Controlled mode

Autonomous mode

long

Close,
Close
Enable automatic establishment
of chain,
Enable FE auxiliary
establishment of chain

long

Disable automatic chainestablishment switch:


[Try Ethernet/PPP/ATM mode,
Try Ethernet/PPP mode, Try
Ethernet/ATM mode, Try
Ethernet mode, Try PPP/ATM
mode,
Try PPP mode, Try ATM mode],
Enable automatic establishment
of chain:
[Try
Ethernet/PPP/ATM mode,
[1..300]
Try Ethernet/PPP mode, Try
Ethernet/ATM mode, Try
Ethernet mode, Try PPP/ATM
mode,
Try PPP mode, Try ATM mode],
Enable FE auxiliary
establishment of chain:
[Try Ethernet mode]

long

Disable automatic chainestablishment switch:


[Try Ethernet/PPP/ATM mode],
Enable automatic establishment of
chain:
[Try Ethernet/PPP/ATM mode],
Enable FE auxiliary establishment of
chain:
[Try Ethernet mode]
10

<>

302 , 242

ZTE
long

[1..300], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

<>

302 , 243

ZTE
long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

<>

302 , 244

ZTE
long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

<>

302 , 245

ZTE
long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

<>

302 , 246

ZTE
long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

[0x00..0x3F], Invalid

Invalid

long

Electrical port self-adaptive,


Electrical port 10Mbps FDT,
Electrical port 100Mbps FDT,
Optical port 100Mbps FDT,
Optical port 1000Mbps FDT,
Optical port 1000Mbps selfadaptive,
Optical port 10000Mbps FDT

Electrical port self-adaptive

unsigned long

Self Negotiation: [100..1000000]


step 100,
Electrical port 10Mbps FDT:
[100..10000] step 100,
Electrical port 100Mbps FDT:
[100..100000] step 100,
Optical port 1000Mbps FDT:
[100..1000000] step 100,
Optical port 100Mbps FDT:
[100..100000] step 100
Optical port 10000Mbps FDT:
Close,
[100..10000000] step 100
Open
Optical port 1000Mbps selfadaptive: [100..1000000] step
100

Self Negotiation: [100000],


Electrical port 10Mbps FDT: [10000],
Electrical port 100Mbps FDT:
[100000],
Optical port 1000Mbps FDT:
[1000000],
Optical port 100Mbps FDT: [100000],
Optical port 10000Mbps FDT:
[10000000]
Optical port 1000Mbps self-adaptive:
[1000000]
0

long

<>

302 , 247

ZTE
long

[15..1000]

30

<>

302 , 248

ZTE

Unit
kbps

EMS Path
Managed
Element/Transmission
Network/ATM Transport
Network/AAL2

Possible Means of Parameter Setting


Modification
Off-line modifications can be made
through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Managed
Element/Transmission
Network/ATM Transport
Network/SaalUni

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

kbps

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

<>

302 , 249

ZTE
N/A

N/A
N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

Managed
N/A
Element/Equipment/Cabin
N/A
et

N/A

Managed
N/A
Element/Transmission
Network/Network
Detection/Maintenance Point

N/A

N/A

N/A

Managed
N/A
Element/Transmission
Network/Network
Detection/Maintenance Point

N/A

N/A

N/A

Managed
Element/Transmission
Network/Network
Detection/Bidirectional
Forwarding Detection

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Managed
Element/Transmission
Network/Network
Detection/Ethernet Fault
Detection Configuration

N/A

N/A

<>

302 , 250

ZTE
times

N/A

N/A

Managed
Element/Transmission
Network/Network
Security/IPSec Security
Policy Database Object

N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A

Managed Element/System
Parameter/SON Function
Switch Object

N/A

N/A

Managed Element/System
Parameter/SON Function
Switch Object

N/A

N/A
N/A

N/A
Managed Element/System
Parameter/SON Function
Switch Object

N/A

N/A

N/A

min

N/A

<>

302 , 251

ZTE
min

N/A

N/A

Managed
Element/Transmission
Network/Signalling and
Business/Service and DSCP
mapping

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

<>

302 , 252

ZTE
N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

<>

302 , 253

ZTE
N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

<>

302 , 254

ZTE
N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

<>

302 , 255

ZTE
N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

Off-line modifications can be made


through GUI. Synchronizing the modified
tables to BTS is required to bring such
modifications into effect.

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Managed
Element/Transmission
Network/Physical
Hosting/Physical Layer Port

kbps

N/A

N/A

Use GUI to modify parameters. Then


perform the delivering modified data
operation so that the modified data
become valid at base station.

Managed Element/System
Parameter/SON Function
Switch Object

N/A

<>

302 , 256

ZTE
min

N/A

<>

302 , 257

ZTE

When to Take Effect

Impact on Service

Related Parameters

With immediate effect

N/A

N/A

With immediate effect

N/A

serviceCategory

With immediate effect

N/A

serviceCategory

With immediate effect

N/A

N/A

With immediate effect

N/A

serviceCategory

With immediate effect

N/A

serviceCategory

With immediate effect

N/A

N/A

With immediate effect

N/A

N/A

With immediate effect

N/A

serviceCategory

With immediate effect

N/A

serviceCategory

With immediate effect

N/A

N/A

With immediate effect

N/A

serviceCategory

With immediate effect

N/A

serviceCategory

<>

302 , 258

ZTE
With immediate effect

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

<>

302 , 259

ZTE
N/A

N/A

N/A

N/A

N/A

N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

With immediate effect

N/A

N/A

N/A

N/A

functionSwitch

N/A

N/A

functionSwitch

<>

302 , 260

ZTE
N/A

N/A

functionSwitch

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

<>

302 , 261

ZTE
It is required to synchronize the N/A
modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

<>

302 , 262

ZTE
It is required to synchronize the N/A
modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

<>

302 , 263

ZTE
It is required to synchronize the N/A
modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

<>

302 , 264

ZTE
It is required to synchronize the N/A
modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

It is required to synchronize the N/A


modified tables.

N/A

With immediate effect

N/A

refGeDevice

With immediate effect

N/A

refGeDevice
operatingMode

With immediate effect

N/A

N/A

<>

302 , 265

ZTE
With immediate effect

N/A

functionSwitch

<>

302 , 266

ZTE

Reference Protocol

Parameter Explanation

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the maximum transmission bandwidth.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the average transmission bandwidth.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the minimum sending bandwidth (that is, the


minimum bandwidth guaranteed for sending).

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the maximum receiving bandwidth.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the average receiving bandwidth.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the minimum receiving bandwidth (that is, the


minimum bandwidth guaranteed for receiving).

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the category of ATM services. All categories of


ATM services can be divided into two types: real-time
services (SRVC_CBR and SRVC_RTVBR) and nonreal-time services (SRVC_NRTVBR, SRVC_UBR,
SRVC_ABR, and SRVC_OTHER). Real-time services
are generally used for transmitting voice and signaling
data. Non-real-time services are generally used for
transmitting data services.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the maximum transmission bandwidth.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the average transmission bandwidth.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the minimum sending bandwidth (that is, the


minimum bandwidth guaranteed for sending).

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the maximum receiving bandwidth.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the average receiving bandwidth.

ITU-T I.363.2 B-ISDN ATM Adaptation Layer


specification: Type 2 AAL

Indicate the minimum receiving bandwidth (that is, the


minimum bandwidth guaranteed for receiving).

<>

302 , 267

ZTE
ITU-T I.363.2 B-ISDN ATM Adaptation Layer
specification: Type 2 AAL

Indicate the category of ATM services. All categories of


ATM services can be divided into two types: real-time
services (SRVC_CBR and SRVC_RTVBR) and nonreal-time services (SRVC_NRTVBR, SRVC_UBR,
SRVC_ABR, and SRVC_OTHER). Real-time services
are generally used for transmitting voice and signaling
data. Non-real-time services are generally used for
transmitting data services.

N/A
N/A

Specify the product name. Refer to Physical


Device Definition for product names.
Uniquely identify a product.

802.1ag

Indicate the local MEP level.

802.1ag

Indicate the lowest alarm level of the local MEP. The


local MEP only responds to the received alarm whose
level is higher than the lowest level.

N/A

Indicate the local MP index (EthernetCfmMp.mpIndex)


associated with the remote MEP.

N/A

Indicate the MAC address of the remote MEP. The digits


in the MAC address are separated with the symbol "-",
such as, 00-AA-BB-88-99-DD.

RFC 5880

Indicate the BFD authentication type. It is a parameter


for interconnection.

RFC 5880

It uniquely identifies authentication key. It is a parameter


for interconnection.

RFC 5880

Indicate the authentication key that consists of 20


values, with each within the range of 0-255. Different
values are separated by a dot.
(1) When the authentication type is 1, the valid value of
the authentication password is the first 5 values.
(2) When the authentication type is 2 or 3, the valid
value of the authentication password is the first 16
values.
Default value is: 0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0

N/A

Indicate the event type that needs to be configured.

N/A

Indicate the window size of the corresponding event


type.
eventType=0, unit: second.
eventType=1, unit: ten thousand PPS.
eventType=2, unit: second.
eventType=3, unit: million PPS.

<>

302 , 268

ZTE
N/A

Indicate the threshold of the corresponding event type.

N/A

It uniquely identifies an IPSec SPD security policy.

N/A
N/A
N/A
N/A

Indicate the source address.


Indicate the subnet mask of the source address.
Indicate the destination address.
Indicate the subnet mask of the destination address.

N/A
N/A
N/A
N/A
N/A
N/A
N/A

Indicate the protocol upper limit.


Indicate the protocol lower limit.
Indicate the upper limit of the source port.
Indicate the lower limit of the source port.
Indicate the upper limit of the destination port.
Indicate the lower limit of the destination port.
Indicate the action that shall be taken when the IPSec
rule is fulfilled.

N/A

Enable or disable hardware auto-discovery function.

N/A

Enable or disable auto-commissioning function.

N/A

Indicate operating mode of auto-commissioning function.

N/A

Indicate automatic chain-establishment switch. The


automatic chain-establishment function means that the
base station automatically establishes the O&M channel
between various physical media and OMC.

N/A

Select on which physical media the automatic chainestablishment is attempted. Precisely selecting the
transmission mode can accelerate the automatic chainestablishment.

N/A

Indicate when to initiate automatic connection after the


link is broken for the first time. The automatic connection
is started by the base station if the broken duration of
the following parameters exceed this value:
Transmission layer control link (SCTP, SSCOP), LMT
O&M channel, and OMC O&M channel.

<>

302 , 269

ZTE
N/A

Indicate when to initiate automatic connection after the


link is broken after the first time. The automatic
connection is started by the base station if the broken
duration of the following parameters exceed this value:
Transmission layer control link (SCTP, SSCOP), LMT
O&M channel, and OMC O&M channel.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 1 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 2 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 3 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 4 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 5 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 6 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 7 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 8 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 9 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 10 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 11 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 12 of LTE service.

<>

302 , 270

ZTE
RFC2474 - Definition of the Differentiated
Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 13 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 14 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 15 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 16 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 17 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 18 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 19 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 20 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 21 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 22 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 23 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 24 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 25 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 26 of LTE service.

<>

302 , 271

ZTE
RFC2474 - Definition of the Differentiated
Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 27 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 28 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 29 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 30 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 31 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 32 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 33 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 34 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 35 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 36 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 37 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 38 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 39 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 40 of LTE service.

<>

302 , 272

ZTE
RFC2474 - Definition of the Differentiated
Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 41 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 42 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 43 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 44 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 45 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 46 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 47 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 48 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 49 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 50 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 51 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 52 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 53 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 54 of LTE service.

<>

302 , 273

ZTE
RFC2474 - Definition of the Differentiated
Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 55 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 56 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 57 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 58 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 59 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 60 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 61 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 62 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 63 of LTE service.

RFC2474 - Definition of the Differentiated


Services Field (DS Field) in the IPv4 and IPv6
Headers

Transmission priority 64 of LTE service.

IEEE802.3

The Ethernet working mode. It should match with the


configuration on the opposite end. The rate mode
configuration depends on whether it is supported by the
Ethernet cable.

IEEE802.3

Transmission bandwidth in the Ethernet transmission


mode.

N/A

Enable or disable the function of configuration rollback.

<>

302 , 274

ZTE
N/A

When the link-broken time of LMT O&M channel and


OMC O&M channel exceeds this duration, the
configuration data of BS is automatically rolled back.

<>

302 , 275

ZTE

Change Records
No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

<>

302 , 276

ZTE

No change

No change
No change
No change

No change

No change

No change

No change

No change
No change

No change

No change

<>

302 , 277

ZTE

No change

No change

No change
No change
No change
No change
No change
No change
No change
No change
No change
No change
No change

No change

No change

No change
No change

No change

No change

<>

302 , 278

ZTE

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

<>

302 , 279

ZTE

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

<>

302 , 280

ZTE

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

<>

302 , 281

ZTE

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

<>

302 , 282

ZTE

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

No change

<>

302 , 283

ZTE

No change

<>

302 , 284

ZTE

<>

302 , 285

ZTE

<>

302 , 286

ZTE

<>

302 , 287

ZTE

<>

302 , 288

ZTE

<>

302 , 289

ZTE

<>

302 , 290

ZTE

<>

302 , 291

ZTE

<>

302 , 292

ZTE

<>

302 , 293

ZTE

<>

302 , 294

ZTE

<>

302 , 295

ZTE

<>

302 , 296

ZTE

<>

302 , 297

ZTE

<>

302 , 298

ZTE

<>

302 , 299

ZTE

<>

302 , 300

ZTE

<>

302 , 301

ZTE

<>

302 , 302

Você também pode gostar