Meter At A Glance
JEM10
Polyphase
Measurements
Instantaneous
Measurements
Demand
Measurements
Time-of-Use
Features
Bidirectional
Watthours
Watts Delivered
Peak
4 Rates
Watts Received
Watts
4 Seasons
Vars Delivered
Vars
20-Year Calendar
Vars Received
Volt-Amperes
200 Holidays
Bidirectional
Varhours, as:
Common, Net, or
Total
Quadrant 1
Quadrant 2
Quadrant 3
Quadrant 4
V2h
VA Delivered
VA Received
2 Holiday Rates
Storage
Registers
Fully
Configurable
Load Profile
Recording
Communication
Options
Data System
RS-232
Typical:
40 days of
15-minute,
5-channel data
Demand Threshold
20 mA Current Loop
JAV Data-Acquisition
Software Alarm
Phase Loss
Trend Link
Optical Port
Alerts Modem to
Pager, Data-Log
Printers, or Terminal
Event
Recording/Alarm
MV-90 Compatible
8 Rate Changes
Per Day
Billing
Reset Storage
Previous Season
Registers
Trend Link is a Registered Trademark of Canary Labs, Inc.
10/31/97 4:32 PM
Page 4
Forms Inexpensive
Data-Communication System with
JAV Data-Acquisition Software
Large, Readable
LCD Display
Demand
Threshold Alert
Call Originate
on Event Modem
True, Real-Time
Analog Outputs
Time-of-Use:
10 Registers, Four TOU
Rates, 20 Yr. Calendar
Call Originate
on Power Fail
JEMSET
Configuration Software
Voltage Phase
Loss Alarm
Five Pulse
Outputs, Form-C,
Surge Protected
Case Styles:
A, S,
9 Switchboard
Applications
JEM10
JEM10.
ITS MORE THAN A METER;
ITS A METERING SYSTEM.
Load Survey
Commercial/Industrial
Cogeneration
Substation Metering
Wholesale/High Revenue
0.1% accuracy, long-term stability and
flexible Time-of-Use billing capability
provide power users with an exceptional value for accurate, reliable billing
information.
Energy Management
10/31/97 4:34 PM
Page 5
INTRODUCING JEM10
COMMUNICATION MODEM WITH
PHONE HOME ALERTS
without special
datalinks, software
or disruption to your
natural flow of metering
data.
JEM10 SPECIFICATIONS
Packages
Socket mount, standard forms
Switchboard case; approx. dimensions:
9-1/8" H x 8-5/8" W x 7" D
A-base, surface mount
Voltage Ratings
69, 120, 240, 277 Volt
Optical Instrument Transformer
Current Ratings
ANSI Class 10, Class 20
IEC IN1, IN5
Optical Instrument Transformer
Measurements
Watt/Watthour, Var/Varhour (basic model),
Functions available on other
models include: Bidirectional Watthour,
Q-Hour as an alternate reactive measurement,
V 2Hour
Standard Model Functions
kWh/kvar (lag/lead), kWh/kQh,
kvarh/kvarh/V 2h, kWh/kQh/V 2h
Accuracy
0.1% calibration accuracy
0.2% load linearity
Surge Ratings
ANSI C37.90, ANSI C62.41, IEC 687, SWC
and fast transient to 5 kV
Storage registers:
BPR transfer registers
Season change registers
Time of Use
4 TOU rates (A, B, C, D)
20-year calendar with 200 holidays
4 seasons per year
Daily rate schedule for 9 day types
Previous season registers
Register Quantities
Consumptions registers:
kWh Del, kWh Rec, kvarh Del, kvarh Rec,
kvarh per Quadrant , V 2h
Options
KYZ pulse initiator outputs, up to 5 available
Maximum Demands:
kW Del, kW Rec; kvar Del, kvar Rec;
kvar Del Net, kvar Rec Net;
kvar Del Total, kvar Rec Total;
kVA Del, kVA Rec;
kVA Del Net, kVA Rec Net;
kVA Del Total, kVA Rec Total
old
old
Communications
RS-232 5-wire with RTS/DTR, 300 to 9600 baud
20 mA current loop to 9600 baud
Communication modem, auto-originate on
event, 9600 baud modem
ORDERING INFORMATION
MODEL J10 12005S12-NNNN
Basic Meter
Type Designation
A space
Measurement Function
120 Watthour, Varhour
221 Watthour, Varhour, V2 Hour
130 Watthour, Q-hour
231 Watthour, Q-hour, V2 Hour
Form & Package
Socket Relay
05S
05R
06S
06R
09S
09R
A-Base
05A
06A
09A
Option Field
Up to
4 characters
Class Current
1 10 Amp
2 20 Amp
A Optical I.T.*
Voltage Rating
0 69 Volt
1 120 Volt
2 240 Volt
3 277 Volt
5 69 Volt, 50 Hz
A Optical I.T.*
The JEM10 model number consists of 12 to 17 characters. Twelve characters, including a space following the meter type designation, are used to
define the basic hardware configuration. Up to four characters can be
used for combinations of options. Counting the dash between the base
model and the option designation gives a maximum 17-character field.
*Contact factory with calibration requirements.
Scientific Columbus
maintains a factory
and field
organization
of technically
trained specialists who offer
on-site assistance worldwide.
CER
FIED
TI
Since 1962, Scientific Columbus has been a leading supplier to power utilities and industrial users of power. The
proven performance of Exceltronic and Digilogic power
transducers, JEM electronic meters, the MicroJoule
Laboratory Standard and the SC-30 Field Standard has earned
Scientific Columbus a reputation for reliable products that
maintain high-accuracy specifications with little or no maintenance.