Escolar Documentos
Profissional Documentos
Cultura Documentos
Radial Vibration
Thrust Position
Differential Expansion
Eccentricity
REBAM*
Acceleration
Velocity
Shaft Absolute
Note: The monitor channels are programmed in pairs and can perform up to two of these functions
at a time. Channels 1 and 2 can perform one function, while channels 3 and 4 perform another (or
the same) function.
2.
Specifications
Inputs
Acceleration
and
Acceleration2
10 mV/ (m/s2) (100 mV/g).
Signal
Accepts from 1 to 4 proximity,
velocity or acceleration
transducer signals.
Velocity and
Velocity2
20 mV/ (mm/s) pk (500 mV/ (in/s)
pk), or
Input
Impedance
Standard I/O
10 k (Proximitor and
Acceleration Inputs).
TMR I/O
The effective impedance of three
Bussed TMR I/O channels wired in
parallel to one transducer is 50
k.
Power
Consumption
Shaft Absolute,
Radial Vibration
3.94 mV/m (100 mV/mil), or
7.87 mV/m (200 mV/mil).
Shaft Absolute,
Direct
3.94 mV/m (100 mV/mil), or
Sensitivity
Radial Vibration
3.94 mV/m (100 mV/mil), or
Thrust
3.94 mV/m (100 mV/mil), or
Circular
Acceptance
Region
See Radial Vibration.
Outputs
0.394 mV/m (10 mV/mil), or
0.787 mV/m (20 mV/mil).
REBAM
40 mV/m (1000 mV/mil), or
Front Panel
LEDs
OK LED
Indicates when the 3500/42M is
operating properly.
Signal Conditioning
Buffered
Transducer
Outputs
Radial Vibration
Frequency
Response
Direct filter
User-programmable, single-pole,
-3db at 4 Hz to 4000 Hz or 1 Hz to
600 Hz, 1% accuracy.
550
Transducer
Power Supply
Gap filter
-24 Vdc
Recorder
-3 dB at 0.09 Hz.
Not 1X filter
Resolution
Accuracy
Direct and Gap
Exclusive of filtering, within
0.33% of full-scale typical, 1%
maximum.
1X and 2X
The Shaft Absolute I/O modules
have one output for each channel
Within 5% maximum.
Not 1X
3% for machine speeds less
than 30,000 cpm.
8.5% for machine speeds
greater than 30,000 cpm.
10 to 14,500 Hz
10 to 14,500 Hz
Filter quality
Thrust and
Differential
Expansion
High-Pass
4-pole (80 dB per decade, 24 dB
per octave).
Frequency
Response
Low-Pass
Direct filter
-3 dB at 1.2 Hz.
Gap filter
Accuracy
-3 dB at 0.41 Hz.
Accuracy
Within 0.33% of full-scale
typical, 1% maximum.
Acceleration II
Frequency
Response
Eccentricity
Frequency
Response
Bias filter
-3 dB at 0.01 Hz
Direct filter
Not OK filter
-3 dB at 15.6 Hz.
-3 dB at 2400 Hz
Gap filter
1X and 2X
Vector filter
-3 dB at 0.41 Hz.
Accuracy
Within 0.33% of full-scale
typical, 1% maximum.
Acceleration
Frequency
Response
The following table shows the
frequency ranges if both channels
of a channel pair are enabled:
Output
Type
Without Filter
RMS
10 to 30,000
Hz
3 to 30,000
Hz
Peak
With Integration
Low- or
High-Pass
Filter
10 to 9,155
Hz
3 to 9,155
Hz
With Integration
10 to 20,000 Hz
10 to 20,000 Hz
With
Integration
10 to 9,155
Hz
10 to 9,155
Hz
Specifications and Ordering Information
Part Number 143694-01
Rev. K (06/13)
Page 4 of 18
Accuracy
Filter Quality
High-Pass
4-pole (80 dB per decade, 24 dB
per octave).
Low-Pass
4-pole (80 dB per decade, 24 dB
per octave).
Velomitor*
Sensor
Accuracy
Full Scale 0-0.5: 3% Typical
Full Scale 0-1.0: 2% Typical
Accuracy
Velocity and
Velocity II
Shaft Absolute,
Radial Vibration
Frequency
Response
Frequency
Response
Direct filter
User-programmable, 4 Hz to 4000
Hz or 1 Hz to 600 Hz.
Bias
-3dB at 0.01 Hz (Velocity II only)
Gap filter
Not OK filter
-3 dB at 0.09 Hz.
-3 dB at 40 Hz (Velocity II only)
1X Vector filter
RMS
Accuracy
3 to 5,500 Hz, -3 dB
1X and 2X
Vector filter
Valid for machine speeds of 60 to
100,000 cpm. (Velocity II only)
1X
Within 0.33% of full-scale
typical, 1% maximum.
Filter Quality
Shaft Absolute,
Velocity
High-Pass
2-pole (40 dB per decade, 12 dB
per octave).
Frequency
Response
Low-Pass
4-pole (80 dB per decade, 24 dB
per octave).
Peak or
Peak-to-Peak
User-programmable, 1 to 4,000
Hz, -3 dB.
Specifications and Ordering Information
Part Number 143694-01
Rev. K (06/13)
Page 5 of 18
Filter Quality
High-Pass
2-pole (40 dB per decade, 12 dB
per octave).
Low-Pass
2-pole (40 dB per decade, 12 dB
per octave).
1X Vector filter
1X Vector filter
Nominal Shaft
Speed (Hz)
Valid Speed
Range (Hz)
10 to <126
126 to <252
252 to <504
504 to 584
0.071 to 160
0.133 to 330
0.25 to 660
0.50 to 750
REBAM
Frequency
Response
approximately 20 KHz.
Filter Quality
Spike
Spike high-pass
User-programmable from 0.152
to 8678 Hz.
Element
User-programmable for BPFO
ranging from 0.139 to 3836 Hz.
High-pass corner is 0.8x BPFO.
Low-pass corner is 2.2x BPFO.
Element
bandpass
Rotor low-pass
Rotor
Direct
Programmable from 3.906 to 14.2
Hz. Selection is determined by
Spike and Rotor filters.
Rotor, Direct
high-pass
Gap
Specifications and Ordering Information
Part Number 143694-01
Rev. K (06/13)
Page 6 of 18
Alarms
Alarm setpoints
The user can use software
configuration to set Alert levels
for each value measured by the
monitor and Danger setpoints for
any two of the values measured
by the monitor Alarms are
adjustable from 0 to 100% of fullscale for each measured value.
The exception is when the fullscale range exceeds the range of
the transducer. In this case, the
range of the transducer will limit
the setpoint. Accuracy of alarms
is to within 0.13% of the desired
value.
Accuracy
Amplitude
Within 0.33% of full scale typical,
1% maximum when input signal
is at the center frequency of the
proportional value's passband.
Phase
3 degrees error, maximum.
Channels
enabled
Certain configurations allow the
user to enable only one channel
of a channel pair. See the
discussion and graphs in the final
pages of this datasheet.
Filter tracking/
stepping
(requires a valid
speed signal)
Alarm Time
Delays
Note: Applies to Radial Vibration, Thrust, Differential Expansion,
Eccentricity, Acceleration, Velocity, Acceleration2, Velocity2,
Circular Acceptance Region, Shaft Absolute Radial Vibration
Initial condition
Alert
Nominal filter set used.
Acceleration
Direct, defined as one of the
following:
Alert
RMS Acceleration, or
Peak Acceleration, or
Danger
RMS Velocity, or
From 1 to 60 seconds in 0.5
second intervals.
Peak Velocity, or
Band-pass peak Acceleration, or
Band-pass peak Velocity.
Acceleration II
REBAM
RMS Acceleration, or
From (calculated minimum value)
to 400 seconds in 1 second
intervals.
Peak Acceleration, or
RMS Velocity, or
Peak Velocity, or
Danger
Static Values
Static values are measurements used to monitor the
machine. The Proximitor/Seismic Monitor returns the
following static values:
Velocity
Direct, defined as one of the
following:
Radial Vibration
RMS Velocity, or
Thrust Position
Band-pass, or
Direct, Gap
Differential
Expansion
Peak-to-peak Displacement.
Velocity II
Direct, Gap
Eccentricity
RMS Velocity, or
REBAM
Peak-to-peak Displacement.
Additionally, 1X Phase, 2X Phase
and Bias Voltage.
Shaft Absolute, Radial
Vibration and Shaft
Absolute, Velocity
Direct, Gap, 1X Amplitude, 1X
Phase Lag
Channel
Parameters
(entity)
Vmax = 27.25 V
Imax = 91.8 mA
Rmin (PWR) = 297
Environmental Limits
Operating
Temperature
Circular
Acceptance
Region
Barrier Parameters
The following parameters apply for both CSA-NRTL/C
and ATEX approvals.
Proximitor
Barrier
Circuit Parameters
Vmax (PWR) = 26.80 V
(SIG) = 14.05 V
Imax (PWR) = 112.8 mA
(SIG) = 2.82 mA
Rmin (PWR) = 237.6
(SIG) = 4985
Channel Parameters
(entity)
Vmax = 28.0 V
Imax = 115.62 mA
Rmin (PWR) = 237.6
(SIG) = 4985
Humidity
95%, noncondensing.
Electrical Safety
Standards:
EN 61010-1
Seismic Barrier
Circuit
Parameters
Vmax (PWR) = 27.25 V
Imax (PWR) = 91.8 mA
T4 @ Ta = -20C to +65C
North American
(-4F to +150F)
Approval Option
(01)
When used with I/O module ordering
options with internal barriers:
Brazil
Approval Option
(02)
T4 @ Ta = -20 C to +65 C
(-4 F to +150 F)
(-4 F to +150 F)
per drawing 138547
When used with I/O module ordering
options without internal barriers:
Ex nC [L] IIC: Class I, Div 2
AEx nC IIC: Class 1, Div 2
Groups A, B, C, D
South Africa
Approval Option
(02)
T4 @ Ta = -20 C to +65 C
(-4 F to +150 F)
per drawing 149243
ATEX
T4 @ Ta = -20 C to +65 C
Approval Option
(02)
(-4 F to +150 F)
For Selected Ordering Options
with ATEX/CSA agency
approvals:
For ATEX agency approval
ordering options with internal
barriers:
II 3/(1) G
Ex nC[ia Ga] IIC T4 Gc
T4 @ Ta = -20C to +65C
Physical
Monitor Module
(Main Board)
(-4F to +150F)
For ATEX agency approval
ordering options without internal
barriers:
II 3/(3) G
Dimensions
(Height x Width
x Depth)
241.3 mm x 24.4 mm x 241.8 mm
Specifications and Ordering Information
Part Number 143694-01
Rev. K (06/13)
Page 10 of 18
I/O Module
(non-barrier)
Dimensions
(Height x Width
x Depth)
Internal Barrier
I/O Modules
Consult the 3500 Internal Barrier
specification sheet (part number
141495-01) if the Internal Barrier
Option is selected.
Shaft Absolute
I/O Module
(barrier)
Dimensions
(Height x Width
x Depth)
241.3 mm x 24.4 mm x 163.1 mm
Weight
0.46 kg (1.01 lb.).
REBAM
Monitor Module
I/O Modules
Ordering Information
General
Acceleration II
The Acceleration II channel type
requires the following (or later)
firmware, and software revisions:
Specifications and Ordering Information
Part Number 143694-01
Rev. K (06/13)
Page 11 of 18
Option
A 04
A 05
A 06
B:
06
07
08
09
10
Ordering Option
A 01 & A 02
A 03
Chs 1 and 2
Prox/Accel
Prox/Accel
Velomitor sensor
Chs 3 and 4
Prox/Accel
Velomitorsensor
Velomitor sensor
Ordering Options
A:
See Note 2
X
X
Note 2: The following table shows the ordering options that are
available for Internal Barriers with this monitor.
Velocity II
Circular
Acceptance
Region
X
X
Prox/Accel
Velom
See Note 4
X
X
Seismoprobe
X
128015-08
Proximitor/Velomitor External
Termination Block (Euro Style
connectors).
Proximitor/Velomitor External
Termination Block (Terminal Strip
connectors).
128240-01
126632-01
00530843
143489-01
135489-01
Cables
3500 Transducer (XDCR) Signal to External Termination
(ET) Block Cable
129525 -AXXXX-BXX
A:
B:
Cable Length
0005
0007
0010
0025
0050
0100
Assembly Instructions
01
02
B:
Cable Length
0005
0007
0010
0025
0050
0100
Assembly Instructions
01
02
Spares
176449-02
128229-01
135489-02
135489-03
138708-01
138700-01
00517018
140471-01
140482-01
00561941
00580434
00580432
00502133
1.
2.
3.
4.
5.
Status LEDs
Buffered Transducer Outputs
Prox/Seismic I/O Module with Internal Terminations
Prox/Seismic I/O Module with External Terminations
TMR I/O Module with External Terminations
Specifications and Ordering Information
Part Number 143694-01
Rev. K (06/13)
Page 14 of 18
1.
2.
3.
4.
1.
2.
3.
REBAM* Channels:
The following graphs show the maximum machine speed allowed for a monitor channel pair configured for REBAM.
The top graph assumes both channels of the channel pair are enabled. The bottom graph assumes only one channel
of a channel pair is enabled. The maximum speed is dependent on the number of rolling elements in the bearing. The
graph assumes that the rotor lowpass filter corner is set at 3.2X the shaft speed and the spike highpass filter corner is
set at 4X the element pass frequency for the outer race (BPFO).
Max R PM
20000
15000
10000
5000
0
6
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
32
34
36
38
40
N umber of E lements
Rotor
Element Pass
Spike
Max R PM
30000
25000
20000
15000
10000
5000
0
6
10
12
14
16
18
20
22
24
26
28
30
N umber of Elements
Rotor
Element Pass
Spike
* denotes trademarks of Bently Nevada, INC., a wholly owned subsidiary of General Electric Company.
1999 2013 Bently Nevada Inc., All rights reserved.
Printed in USA. Uncontrolled when transmitted electronically.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 775.782.3611
Fax: 775.215.2873
www.ge-mcs.com/bently