Você está na página 1de 4

APPENDIX E - NTMP01 TERMINATION UNIT

CONFIGURATION
INTRODUCTION
The INICT03 INFI-NET to Computer Transfer Module (through
the IMMPI01 Multi-Function Processor Interface Module (MPI)
can use the NTMP01 termination unit for termination. Jumpers on the TMP unit configure the two RS-232-C ports for data
terminal equipment (DTE) or data communication equipment
(DCE). One of the RS-232-C ports can be configured as an
RS-485 port. Refer to the NTMP01 instruction for complete
information.
Figures E-1, E-2, E-3, and E-4 show the jumper configurations
for jumpers J1 and J2. Figure E-5 shows the jumper configurations for jumpers J3 through J10. Figure E-6 shows the
jumper configurations for jumpers J14 through J17. Figure
E-7 shows the NTMP01 connector assignments and jumper
locations.
Jumpers J11 and J12 are storage posts for extra jumpers.
Jumper J13 is normally set with pins one and two connected.
This connects the cable shielding pin of connector P7 to chassis ground. Jumper J18 configures the terminal serial port for
RS-485 operation when pins two and three are connected and
connector P7 is used instead of connector P5.
J1 AND J2
RXD

TXD-A
RXD-A

RTS-A

11
CTS-A

10

TXD

RTS

DB25-3

DB25-2

DB25-4

12
CTS

DB25-5

TP25051B .

Figure E-1. DTE Jumper Configuration for NTMP01


Termination Unit

I-E96-610A

INTRODUCTION
E-1

NTMP01 TERMINATION UNIT CONFIGURATION

J1 AND J2
RXD

TXD-A
RXD-A

RTS-A

11

10

TXD

RTS

DB25-3

DB25-2

DB25-4

12
CTS

CTS-A

DB25-5
TP25052B .

Figure E-2. DCE Jumper Configuration for NTMP01


Termination Unit

J1 AND J2

RXD

TXD-A
RXD-A

RTS-A

11
CTS-A

10

TXD

RTS

DB25-3

DB25-2

DB25-4

12
CTS

DB25-5
TP22115A

Figure E-3. NTMP01 Nonhandshake Jumper Configuration

INTRODUCTION
E-2

I-E96-610A

NTMP01 TERMINATION UNIT CONFIGURATION

J1 AND J2
RXD

TXD-A
RXD-A

RTS-A

11

10

TXD

RTS

DB25-3

DB25-2

DB25-4

12
CTS

CTS-A

DB25-5
TP22116A

Figure E-4. NTMP01 Loopback Jumper Configuration

+12 V

J6 AND J8
1

DSR

DB25-6

J5 AND J9
1

DCD

DB25-8

J7 AND J10
1

DTR

DB25-20

J4 AND J3
1

PROT-GND

GND

DB25-1

DB25-7

NOTE:
JUMPERS J3, J8, J9 AND J10 RELATE TO THE P6
CONNECTOR. JUMPERS J4, J5, J6 AND J7 RELATE
TO THE P5 CONNECTOR.
TP22140A .

Figure E-5. NTMP01 Jumpers J3 through J10 Configuration

I-E96-610A

INTRODUCTION
E-3

NTMP01 TERMINATION UNIT CONFIGURATION

J14
1

J14

DIGIN 1 (+)

CTSB (+)

26

P8

CTSB (+)

P1

J15
1

P8

25

P1

DIGIN 1 (-)

CTSB (-)

P8

26

P1

P8

25

P1

P8

34

P1

P8

33

P1

J16

J16
2

P8

34

P1

P8

33

P1

J17
1

J15
DIGIN 1 (-)
CTSB (-)

DIGIN 1 (+)

J17

HANDSHAKE

DIGITAL I/O

TP25216B

Figure E-6. NTMP01 Jumpers J14 through J17 Configuration

MFP2
ACTIVE

STATION
COM. B
NTMP01

P2

MFP2

J2

+24 V

J17

FUSE F1
CHASSIS
GROUND
COM

E2

TERMINAL
PORT

J4
J5
J6
J7

J16

RS-485 PORT

P5

CR1

J12

J13

DIGITAL
INPUT

P4
SPARE
P8

P7
E1
P3

J1

MFP1

CR2

E3

J14
J15

J18

PRINTER
PORT

J3
J9
J8
J10
J11
P6
SPARE

P1

STATION
COM. A

MFP1
ACTIVE
TP25067B

Figure E-7. NTMP01 Connector Assignments and Jumper Locations

INTRODUCTION
E-4

I-E96-610A

Você também pode gostar