Você está na página 1de 44

5-1

Crouse-Hinds
Hazardous Area Lighting

Product
Series

Description

Area
Classification

Page
No.

AEV

Incandescent

Zone 1

5-2

AEVA-EOLA

Obstruction Marker

Zone 1

5-6

T100A

Small Bulkhead Luminaire

Zone 1

5-7

eLLK92

Ceiling Mount Lighting Fixtures

Zone 1

5-8

eLLM92

Pole Mount Lighting Fixtures

Zone 1

5-11

eLL92

Emergency Lighting Fixtures

Zone 1

5-13

AEVF

Exd Fluorescent Luminaires

Zone 1
and Zone 21&22

5-15

Zone 2
and Zone 21&22

5-16

Zone 2
and Zone 21&22

5-18

Zone 1
and Zone 21&22

5-20

Zone 1
and Zone 21&22

5-21

Exde Hazard Gard HID Lighting Fixtures Zone 1


Integral Ballast
and Zone 21&22

5-26

Champ HID Exn / DIP


Lighting Fixtures

Zone 2
and Zone 21&22

5-34

Exn Floodlight Luminaire

Zone 2
and Zone 21&22

5-39

Zone 1
and Zone 21&22

5-42

Zone 1
and Zone 21&22

5-43

Incandescent

Fluorescent

NDFA

Exn/DIP Heavy Duty Fluorescent


Exn/DIP Fluorescent Lighting Fixtures

AEVBH
EVM

Large Bulkhead Luminaire


Hazard Gard HID Lighting Fixtures
Integral Ballast Factory Sealed

EVME
NVMV
Floodlights
NFMV
Beacons
FSFB301
FRFB301

May 2003

Flashing Beacon
Rotating Beacon

Copyright 2003 Cooper Industries, Inc

Hazardous

H.I.D.

Area
5 Lighting

nLLK

5-2
Crouse-Hinds
AEV
Incandescent
Lighting Fixtures

Flameproof, Exd, IIC, IP66


Zone 1

Application:
AEV incandescent lighting fixtures are
used:
In locations which are hazardous
due to the presence of flammable
vapours or gases and where
dampness or corrosion are present
In petroleum refineries, chemical
and petrochemical plants and other
process industry facilities where
similar hazards exist
As pendant, ceiling, wall bracket or
bulkhead fixtures indoors for general
area or room lighting, or outdoors for
"spot" lighting

Features:

Factory sealed - no external seal

5 Area
Lighting

Hazardous

needed
Easy to assemble and relamp
Shock absorbing receptacle
Gasket seals out dirt and liquids

Positive locking of globe holder


Inner reflector eliminates upward
spill light

Light weight, corrosion resistant,


copper-free aluminium

Standard Materials:

Body and guard ........ Copper free


aluminium

Glass ..... configurated glass, heat


and impact resistant

Standard Finish:

Body and guard ....................Grey


polyurethane

Size Ranges:

20mm through 40mm hubs


Capacity Ranges:

100W to 300W incandescent 160W


self ballasted mercury vapour
25W SL fluorescent lamp

Options:

Reflectors
Exit Sign AEVX ........ See

Compliances:

AS2380

Electrical equipment for


explosive atmospheres - Flameproof
enclosure
AS1939 - Degrees of Protection IP66
Certificate of Compliance No. Ex 491

Temperature Classification to AS2480


Incandescent
Self-Ballasted Mercury
Lamp Size
T Rating Lamp Size T Rating
100W
T5
160W
T4
150W
T5
200W
T5
300W
T4

SL Fluorescent
Lamp Size T Rating
18W
T6
25W
T6

Accessories on page 5-4

May 2003

Copyright 2003 Cooper Industries, Inc

5-3
Crouse-Hinds

Ordering Information:
Max. Lamp
Size

Style
WithGuard

Hub
Size
20mm
25mm

Pendant
AEVA211
AEVA221

Ceiling
AEVCX211
AEVCX221

Wall
Bracket
AEVBX211
AEVBX221

Bulkhead
AEVJ211
AEVJ221

WithoutGuard

20mm
25mm

AEVA210
AEVA220

AEVCX210
AEVCX220

AEVBX210
AEVBX220

AEVJX210
AEVJX220

With Guard

20mm
25mm

AEVA311
AEVA321

AEVCX311
AEVCX321

AEVBX311
AEVBX321

AEVJ311
AEVJ321

SL25W Fluorescent
Without20mm
AEVA310
160W S/B M/V
Guard
25mm
AEVA320
Notes:
1: Ratings are for lamp base up mounting
2: AEVBX and AEVJ fixtures take 30 angle reflectors only

AEVCX310
AEVCX320

AEVBX310
AEVBX320

AEVJ310
AEVJ320

150W Incandescent
SL 18W Fluorescent

300W Incandescent

Dimensions:
Max. Lamp Size
150W
Incandescent
SL18 Fluorescent

B
322
347
390
359

C
298
324
368
337

318
244

AEVA
AEVCX
AEVBX
AEVJ

216
216
216
216

375
397
441
413

343
368
413
384

333
267

16
16

20
20

16
16

20
20

238

260

1: Ratings are for lamp base up mounting


2: When angle reflectors are used, dimension "b" should be changed as follows: add 70mm to AEVA, AEVBX and AEVCX fixtures.
Add 76mm to AEVJ fixtures.
3. Remove reflector for application with SL25W lamp

May 2003

Copyright 2003 Cooper Industries, Inc

Hazardous

A
184
184
184
184

25mm

Area
5 Lighting

300W
Incandescent
SL25 Fluorescent
160W S/B M/V
Notes:

Type
AEVA
AEVCX
AEVBX
AEVJ

20mm

5-4
Crouse-Hinds
Replacement Parts & Accessories
Lamp Receptacles

Glass and holder assemblies

Guards

30 Angle

High Bay

Reflectors

Receptacles, Guards, Glass &


Holder Assemblies

Material:

5 Area
Lighting

Hazardous

Dome and 30 angle ... white fibreglass reinforced


polyester (Krydon)
High bay ... etched Alzak aluminium with natural finish
Max. Lamp Size
150W incandescent
18W fluorescent
300W incandescent
25W fluorescent
250W S/B M/V

Dome

Style

Diam.

Cat. No.

Dome
30Angle

300mm
300mm

RD63
RA63

Dome
30 Angle
High Bay

400mm
400mm
370mm

RD72
RA72
EV2912

Fixture
Size

Lamp
Receptacle
Cat. No.

Guards
Cat. No.

Glass &
Holder
Assemblies
Cat. No.

100W-150W

EV60

EV505

EV78

200W-300W

EV60

EV502

EV7202

Exit Sign Cover


Cat. No. AEVXA3584

Lamp : 200W

Photometric Data
Fixture with glass,
30 angle reflector
without guard

Total
Lumens Eff%
With
Guard 2090 55.0
Without
Guard 2481 65.3

Measurements taken from A-A' plane

May 2003

Copyright 2003 Cooper Industries, Inc

5-5
Crouse-Hinds
Photometric Data
Fixture with glass and
with or without guard

Fixture with glass, dome


reflector and with or without guard

Lamp Data: 100W through 300W


Note: All data provided is for 200W incandescent lamp.
Use following candlepower / lumens multipliers for other lamp sizes: 100W 0.44; 150W 0.72; 300W 1.57
Example: Zonal
lumens for 200W
lamp without guard
for 20-30 is 218.
Zonal lumens for
150W lamp for 2030 is 218 x 0.72
=157

Example: Zonal
lumens for 200W
lamp without guard
for 20-30 is 366.
Zonal lumens for
150W lamp for 2030 is 366 x 0.72
=263

Coefficient of Utilisation
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff.Ceil. Wall
50
80
30
10

Coefficient of Utilisation
Effective Floor Cavity Reflectance 20%

Room Cavity Ratio


1
2
3
.706
.601
.521
.659
.537
.451
.618
.483
.395

4
.457
.382
.326

5
.403
.330
.275

% Reflectance
Eff.Ceil. Wall
50
80
30
10

Room Cavity Ratio


1
2
3
.700
.618
.547
.672
.576
.497
.648
.540
.457

4
.485
.428
.385

5
.432
.373
.330

.671
.629
.590

.572
.513
.465

.497
.432
.380

.435
.367
.314

.384
.316
.265

70

50
30
10

.685
.659
.636

.606
.566
.535

.538
.490
.453

.476
.424
.382

.423
.369
.328

50

50
30
10

.605
.571
.541

.515
.468
.426

.449
.395
.351

.393
.336
.292

.349
.291
.247

50

50
30
10

.655
.635
.617

.583
.550
.520

.519
.478
.445

.459
.414
.378

.410
.362
.325

30

50
30
10

.545
.519
.494

.464
.426
.392

.404
.361
.324

.355
.308
.269

.316
.266
.229

30

50
30
10

.629
.613
.597

.561
.534
.509

.501
.466
.437

.444
.405
.373

.397
.254
.321

.491
.416
.363
.469
.385
.327
.449
.358
.296
Room Cavity Ratio
6
7
8
.362
.324
.291
.290
.254
.224
.238
.207
.177

.319
.280
.247

.284
.244
.210

10

.430
.395
.367

.385
.348
.317

9
.265
.200
.155

10
.234
.170
.129

.607
.541
.484
.593
.518
.455
.580
.498
.430
Room Cavity Ratio
6
7
8
.389
.350
.316
.331
.294
.261
.290
.255
.221

9
.289
.234
.196

10
.252
.197
.162

50
30
10
% Reflectance
Eff.Ceil. Wall
50
80
30
10
10

50
30
10
% Reflectance
Eff.Ceil. Wall
50
80
30
10

70

50
30
10

.345
.278
.228

.310
.244
.199

.279
.216
.171

.254
.192
.151.

.223
.165
.126

70

50
30
10

.383
.328
.287

.345
.328
.252

.312
.259
.220

.285
.232
.196

.248
.197
.162

50

50
30
10

.313
.256
.214

.282
.224
.185

.254
.200
.160

.232
.178
.141

.205
.153
.117

50

50
30
10

.370
.322
.285

.335
.284
.250

.302
.254
.219

.277
.228
.195

.242
.194
.161

30

50
30
10

.284
.236
.198

.255
.208
.171

.232
.183
.149

.212
.164
.131

.187
.140
.107

30

50
30
10

.360
.316
.283

.324
.281
.247

.294
.249
.217

.270
.224
.193

.235
.191
.159

10

50
30
10

.257
.215
.183

.233
.191
.158

.210
.168
.138

.192
.151
.121

.170
.128
.099

10

50
30
10

.349
.310
.279

.317
.277
.245

.286
.246
.216

.262
.221
.191

.230
.188
.158

May 2003

Copyright 2003 Cooper Industries, Inc

Hazardous

50
30
10

Area
5 Lighting

70

5-6
Crouse-Hinds
AEV-EOLA
Obstruction Marker

Flameproof, Exd, IIC, IP66


Zone 1

Application:
AEV incandescent lighting fixtures are
used:
To aid aircraft navigation in
hazardous locations
To mark towers and process
columns in petroleum refineries or
chemical process plants
To indicate the presence of drilling
rigs or other industrial facilities

Features:

Easy to assemble and re-lamp


Lightweight, corrosion resistant,
copper free aluminium

Red fresnel prismatic lens ensures


high visibility and avoids glare (other
colours also available upon request)
Available in single or double units,
pipe or base mount versions
1 x M20 entry (other entries
available upon request)

5 Area
Lighting

Hazardous

Standard Materials:

Body and guard - Copper free

Ordering Information
Type

Order
Code

Entry
Size

Incandescent
Lamp

Lamp
Holder

Single Unit
Pipe Mount

AEVA-EOLA1*

1 x M20

150W Max

E27

Double Unit
Pipe Mount

AEVA-EOLA2*

1 x M20

150W Max

E27

Single
Base Mount

AEVCX-EOLA1*

4 x M20

150W Max

E27

aluminium

External Lens - Configurated glass,


heat treated and impact resistant
Internal Lens - Coloured glass with
fresnel configuration

Standard Finish:

Body and guard - Grey


polyurethane

Size Ranges:

Dimensions:

150W (max) 240/250V


Incandescent

Compliances:

AS2380

Electrical equipment for


explosive atmospheres - Flameproof
enclosure
AS1939 - Degrees of Protection
IP66
Certificate of Compliance No.
Ex 491

May 2003

Copyright 2003 Cooper Industries, Inc

5-7
Crouse-Hinds
T100A Small
Bulkhead
Luminaire

Flameproof, Exd, IIB, IP66


Zone 1

Application:

For use in hazardous areas where


space is limited and local lighting is
required
In areas where low mounting height
requires a fixture with a low profile
For wall mounting in confined
spaces such as inspection pits
For mounting in pre-cast recesses

Features:

Cast aluminium body with flat

impact resistant glass, cast guard and


mounting feet
The lamp housing is separate from
the terminal housing which allows
direct connection to circuit wiring
without the use of high temperature
cable. The terminal housing is
accessible by means of an inspection
cover
Internal LPF control gear for
fluorescent and HID lamps
Three 25mm entries, 1 on each
side and 1 in the end
Reduced maintenance costs when
used with long life HID light sources

Standard Materials:

Ordering Information:
Lamp Size & Type
100W Incandescent
18W SL type fluorescent
9W PL type fluorescent

Cat. No.
T100A
T18-SL
T09-PL

Temperature Rating
T3
T6
T6

Body and guard........ Copper free


aluminium

Lens...Heat resistant borrosilicate

Dimensions:

glass

Standard Finish:

Natural
Compliances:

AS2380

Electrical equipment for


explosive atmospheres - Flameproof
enclosure
AS1939 - Degrees of Protection
IP66
Certificate of Compliance No.
Ex618

Electrical Rating:

Incandescent .....................100W
Mercury vapour ................... 50W
High pressure sodium ......... 35W
Fluorescent (SL type lamp) ..18W
Fluorescent (PL) type lamp) . 9W
All types .................... 240V/50Hz
May 2003

Copyright 2003 Cooper Industries, Inc

Hazardous

Area
5 Lighting

5-8
Crouse-Hinds
eLLK92 Series
Fluorescent
Lighting Fixtures

Increased Safety, Exde, IIC, IP66


Zone 1

Application:

Suitable for use in areas where

hazardous liquids, gases or vapours


are present during normal operation
Suitable for arduous conditions or
extreme environments
Ideal for walkways, bridges,
tunnels, security lighting, roadways
and process plants where reliable
lighting is required for safe operation
Low profile for use in areas where
very low mounting heights or other
space restrictions exist

Features:

Incorporates CEAG designed

electronic ballasts which are suitable


for use with bi-pin (to IEC 81)
fluorescent lamps
Electronic ballast provides high
luminous efficiency, lower energy
consumption and longer service life
of the lamps
Central locking system operated
by standard SW13 hex socket key
enables fixture to be opened from
single point on fixture housing
Diffuser fastened by 10, 20 and 24
latch points respectively on 18W,
36W, and 58W fixtures
Diffuser hinges from either side
and is also designed to act as a
convenient lamp support when open
to simplify lamp replacement
Automatic disconnect switch
ensures the isolation of all exposed
components when the fixture is
opened
Lamp operation on twin lamp
fixtures is independent so that failure
of one does not affect the other
Large internal terminal compartment
with twist locking knob on the cover
enables ready wiring access
Supplied as standard with 2 x M20
metal entries at each end, complete
with through wiring facility
Wide voltage range

5 Area
Lighting

Hazardous

Standard Materials:

Housing .... Glass-mat reinforced


polyester

Diffuser ........... Polycarbonate


May 2003

Bi Pin Fluorescent Lamp

Electrical Ratings:

Compliances:

EN50014, EN50019, EN50018,

Operating Voltage
AC 110 to 254 V 10% 47 - 63HZ
DC 110 to 230 V 10%
Lamp configurations
2 x 18W, 1 x 36W, 2 x 36W,
1 x 58W, 2 x 58W
Bi-pin 26mm diameter
Terminals ...... L1, L2, L3, L, N, PE
6mm2 maximum, 1 wire per terminal
Ambient Temperature Range .....
-25 C to +50 C

Electrical apparatus for potentially


explosive atmospheres, General
Requirements, Increased Safety e,
Flameproof Enclosure d
EN60529 Specification for degrees
of protection provided by enclosures
(IP Code) IP66
PTB ATEX 96 2144
SAA Aus Ex 3558X

Options:

Alternate entry sizes available,


consult factory for details

Ordering Information:
Type

Lamps

eLLK92018/18
eLLK92036
eLLK92036/36
eLLK92058
eLLK92058/58

2 x 18W
1 x 36W
2 x 36W
1 x 58W
2 x 58W

Rated
Current
0.18A
0.18A
0.34A
0.27A
0.53A

Power
Factor
0.95
0.95
0.95
0.95
0.95

Temp.
Class
T4
T4
T4
T4
T4

Catalogue
No.
1 2265 875 111
1 2263 875 103
1 2266 875 111
1 2264 875 111
1 2267 875 111

Copyright 2003 Cooper Industries, Inc

5-9
Crouse-Hinds
Dimensions
& Mounting Accessories
Dimensions:
eLLk92018/18

eLLK92036 & eLLK92036/36

Hazardous

Area
5 Lighting

eLLK92058 & eLLK92058/58

Mounting Accessories:
Note: Supplied as sets of two
Ceiling Mount D2
Cat No. 2 2480 102 000

Eye bolt A2
Cat No. 2 2480 002 000

Pipe Clamp
Type
R12
R22
R32

Pipe Diameter Height H


Cat No:
38-42mm
85mm 2 2480 462 000
47-50mm
95mm 2 2480 472 000
58-62mm
105mm 2 2480 482 000

Hex Screw S4
Cat No. 2 2480 054 000

May 2003

Copyright 2003 Cooper Industries, Inc

5-10
Crouse-Hinds
Photometric Data
2 x 18 W Fixture

Rated luminous flux of lamps 2 x 18 W = 2,700 Im


Light efficiency in operation:
2 x 18 W = 78%
Illumination data acc. to LiTG B 30

2 x 36 W Fixture

Rated luminous flux of lamps 1 x 36 W = 3,350 lm


Light efficiency in operation:
1 x 36 W = 86%
Illumination data acc. to LiTG B 30

Rated luminous flux of lamps 2 x 36 W = 6,700 lm


Light efficiency in operation:
2 x 36 W = 78%
Illumination data acc. to LiTG B 30

5 Area
Lighting

Hazardous

1 x 36 W Fixture

1 x 58 W Fixture

2 x 58 W Fixture

Rated luminous flux of lamps 1 x 58 W = 5,200 lm


Light efficiency in operation:
1 x 58 W = 81%
Illumination data acc. to LiTG B 30

Rated luminous flux of lamps 2 x 58 W = 10,400 lm


Light efficiency in operation:
2 x 58 W = 72%
Illumination data acc. to LiTG B 30

May 2003

Copyright 2003 Cooper Industries, Inc

5-11
Crouse-Hinds
eLLM92 Series
Fluorescent Pole
Lighting Fixtures

Increased Safety, Exde, IIC, IP66/67


Zone 1

Application:

Suitable for use in areas where

hazardous liquids, gases or vapours


are present during normal operation
Suitable for arduous conditions or
extreme environments
Ideal for walkways, bridges,
security lighting, roadways and
process plants where reliable
lighting is required for safe operation
To provide overhead lighting from
pole end mount position

Features:

Incorporates CEAG designed

electronic ballasts which are suitable


for use with bi-pin (to IEC 81)
fluorescent lamps
Electronic ballast provides high
luminous efficiency, lower energy
consumption and longer service life
of the lamps
Integral pole mounting sleeve
recessed into housing for 44mm
pipe (1 1/4 nominal bore)
Large terminal compartment
readily accessible and located
beneath pole mount
Central locking system operated
by standard SW13 hex socket key
enables fixture to be opened from
one point on housing
Diffuser fastened by 10, 20 and 24
latch points respectively on 18W,
36W and 58W fixtures
Diffuser hinges from either side
and is also designed to act as a
convenient lamp support when open
to simply lamp replacement
Automatic disconnect switch
ensures the isolation of all exposed
components when the fixture is
opened
Lamp operation on twin lamp
fixtures is independent so that failure
of one does not affect the other
Supplied with 25mm cable gland
for 8-17mm cable
Wide voltage range

Bi Pin Fluorescent Lamp

Area
5 Lighting

Hazardous

Electrical Ratings:

Compliances:

EN50014, EN50019, EN50018,

Operating Voltage
AC 110 to 254 V 10% 47 - 63HZ
DC 110 to 230 V 10%
Lamp configurations........
2 x 18W, 2 x 36W
Bi-pin 26mm diameter
Terminals ...... L1, N, PE, 2 x 6mm2
1 wire per terminal
Ambient Temperature Range .....
-25 C to +50 C

Electrical apparatus for potentially


explosive atmospheres, General
Requirements, Increased Safety e,
Flameproof Enclosure d
EN60529 Specification for degrees
of protection provided by enclosures
(IP Code) IP66
PTB96 ATEX 2144
SAA Aus Ex 3558X

Options:

Accessory kit for single ended


through wiring comprising adaptor
with 2 x M25 cable glands...........
.................Cat No. 2 2218 602 000

Standard Materials:

Housing .... Glass-mat reinforced


polyester
Diffuser .......... Polycarbonate

Ordering Information:
Type
eLLM92018/18
eLLM92036/36

Lamps
2 x 18W
2 x 36W

Rated
Current
0.18A
0.34A

Power
Factor
0.95
0.95

Temp.
Catalogue
Class
No.
T4
1 2268 875 101
T4
1 2269 875 101

May 2003

Copyright 2003 Cooper Industries, Inc

5-12
Crouse-Hinds
Dimensions & Photometric Data

Dimensions:
eLLM Pole Mount

Internal View of
Terminal Compartment

Standard

Through wiring
option

5 Area
Lighting

Hazardous

Mounting Accessories:
Wall Mount Bracket W26
Cat No. 2 2485 027 000

Photometric Data:
2 x 18 W Fixture

2 x 36 W Fixture

Rated luminous flux of lamps 2 x 18 W = 2,700 Im


Light efficiency in operation:
2 x 18 W = 6,700 Im
Illumination data acc. to LiTG B 30

Rated luminous flux of lamps 2 x 36 W = 6,700 lm


Light efficiency in operation:
2 x 36 W = 78%
Illumination data acc. to LiTG B 30

May 2003

Copyright 2003 Cooper Industries, Inc

5-13
Crouse-Hinds
eLLK92036/36NiB
Emergency
Lighting Fixtures

Increased Safety, Exdem ib, IIC, IP66


Zone 1

Application:

Suitable for use in areas where

hazardous liquids, gases or vapours


are present during normal operation
Suitable for arduous conditions or
extreme environments
In applications where lighting must
be maintained under emergency
conditions to ensure safe evacuation
of personnel
Ideal for walkways, bridges, tunnels,
roadways and process plants where
reliable lighting is required for safe
operation

Features:

Incorporates CEAG designed

electronic ballasts which are suitable


for use with bi-pin (to IEC 81)
fluorescent lamps
Electronic ballast provides high
luminous efficiency, lower energy
consumption and longer service life of
the lamps
Intelligent microelectronic controller
monitors battery charge cycle
eliminating overcharge and ni-clad
memory effect, extending battery life
Battery charge level indicated by
green LED display
Indicates when an operating
duration test is necessary at six month
intervals as required by safety
regulations
Indication provided after duration
test if a malfunction is apparent
Battery set can be safely replaced
within hazardous environment
Emergency operation can be set for
1.5 or 3 hour duration
Central locking system operated by
standard SW13 hex socket key
enables fixture to be opened from one
point of housing
Diffuser fastened by 10 and 20 latch
points respectively on 18W and 36W
fixtures
Diffuser hinges from either side and
is also designed to act as a
convenient lamp support when open
to simplify lamp replacement
Automatic disconnect switch
ensures the isolation of all exposed
components when the fixture is
opened
Lamp configuration on twin lamp
fixtures is dependent so that failure of
one does not affect the other
Incorporates inhibit function set by
internal wire terminal link to disable
emergency operation for when power
is intentionally removed. Link can also
be wired as external switch, for up to
10 fixtures per switch

May 2003

Compliances:

Housing .... Glass-mat reinforced


polyester
Diffuser ......... Polycarbonate

EN500

14, EN50019, EN50018, EN50028,


EN50020 Electrical apparatus for
potentially explosive atmospheres,
General Requirements, Increased
Safety e, Flameproof Enclosure d,
Encapsulation m, Intrinsic Safety i
EN60529 Specification for degrees
of protection provided by enclosures
(IP Code) IP66
PTB96 ATEX2144
SAA AUS Ex 3558X

Electrical Ratings:

Operating Voltage
AC 220 to 254 V 10%
Lamp configurations

47 - 63HZ

2 x 18W, 2 x 36W
Bi-pin 26mm diameter
Terminals ...... L1, L2, L3, L, N, PE
6mm2 maximum, 1 wire per terminal
Ambient Temperature Range .....
-5 C to +50 C
Emergency operation single lamp
for 1.5 hour or 3 hour, set by internal
wire terminal link

Ordering Information:
Ceiling Mounted Emergency Fittings
Type

Lamps

eLLK92018/18NiB 2 x 18W
eLLK92036/36NiB 2 x 36W

Rated
Current
0.23A
0.4A

Power
Factor
0.95 ind
0.95 ind

Temp.
Class
T4
T4

Catalogue
No.
1 2260 879 111
1 2261 879 111

Power
Factor
0.95 ind

Temp.
Class
T4

Catalogue
No.
1 2273 879 101

Pole Mounted Emergency Fitting


Type

Lamps

eLLM92018/18NiB 2 x 18W

Rated
Current
0.23A

Copyright 2003 Cooper Industries, Inc

Hazardous

Standard Materials:

Area
5 Lighting

Bi Pin Fluorescent Lamp

5-14
Crouse-Hinds
Features, Dimensions
& Photometric Data
Operation:

Battery temperature is
monitored during charge
cycle

Microelectronic controller
monitors charge cycle,
eliminating over charge and
Ni-cad memory effect

Status of the battery charge cycle is indicated by a

series of five green Light Emitting Diodes (LED), each


of which represents 20% of battery capacity. The level
of charge attained is indicated by the leading green
LED which flashes. The charge cycle is complete when
all five green LEDs are on.
Emergency operation commences on mains failure
or when the main supply is switched off. During
emergency operation the remaining battery capacity is
indicated by the number of LEDs which are on.
The red LED begins flashing after six months from
the last successful emergency duration test, or when
during battery discharge a defective power supply or
fluorescent lamp is detected. The red LED will continue
to flash until a successful duration test is completed.

Dimensions:

Charge status indicated


by green LED display
Flashing red LED indicates
when an operating duration
test is necessary at six
month intervals as required
by safety regulations
Red LED continues to
flash after duration test if
a malfunction is apparent
Battery set is replaceable
within hazardous area

5 Area
Lighting

Hazardous

eLLk92018/18 Ni Ceiling Mount - Emergency

eLLK92036/36 Ni Ceiling Mount - Emergency

eLLM92018/18 Ni Pole Mount - Emergency

Mounting Accessories:

Refer to pages 5-9 and 5-12

Photometric Data:

Emergency Operation:
Apply the following luminous flux factors when determining
performance under emergency single lamp operation:
18 W = approx. 1.5 h 90% / 3.0 h 45%
36 W = approx. 1.5 h 45% / 3.0 h 25%
Rated luminous flux of lamps:
1 x 18 W = 1,350 Im
1 x 36 W = 3,350 lm

May 2003

Copyright 2003 Cooper Industries, Inc

5-15
Crouse-Hinds
AEVF Series
Explosionproof
Fluorescent
Lighting Fixture

Flameproof, Exd, IIB, IP66


Zone 1
Combustible Dust
Zone 21 & 22

Application:
AEVF Luminaires are used to illuminate
areas where hazardous liquids, fumes
or gases are present. Areas such as:
Spray Booths
Drum Filling Areas
Process Plants
Combustible dusts present

Features:

Luminaire has been designed to

No. & Size of Lamps

Entries

Temp Rating

AEVF118
AEVF136
AEVF218
AEVF236

1 x 18W
1 x 36W
2 x 18W
2 x 36W

2 x 25mm
2 x 25mm
2 x 25mm
2 x 25mm

T5
T5
T5
T5

Utilisation factors:

Standard Finish:

UF (F)
SHR NOM = 1.75
Room
reflectance
Room Index
C W F
.60 .75 .801.00 1.251.50 2.002.50 3.00 4.00 5.00
.70 .50 .20
.22 N/A .24 .26 .29 .31 .35 .37 .38 .40 .42
.30
.19 N/A .21 .23 .26 .28 .32 .34 .36 .38 .40
.10
.14 N/A .17 .20 .23 .26 .29 .32 .34 .36 .38
.50 .50 .20
.14 N/A .23 .25 .28 .30 .33 .35 .36 .38 .39
.30
.18 N/A .20 .22 .25 .27 .30 .32 .34 .36 .38
.10
.15 N/A .17 .19 .22 .25 .28 .30 .32 .35 .36
.30 .50 .20
.20 N/A .22 .24 .26 .28 .31 .32 .34 .36 .37
.30
.15 N/A .18 .21 .24 .26 .29 .31 .32 .34 .35
.10
.13 N/A .16 .19 .22 .24 .27 .29 .31 .33 .34
.00 .00 .00
.13 N/A .16 .17 .20 .22 .25 .26 .28 .30 .31
Rating: Photometrically tested without ceiling board.
Multiply values by service corrections factors.
Calculated in accordance with CIBS Technical Memorandum No. 5 1980.

Grey polyurethane

Dimensions: (mm)

Standard Materials:

Body ......... copper free aluminium


Stainless steel guard and reflector

Electrical Rating:

240V 50Hz
Twin and single lamps PL18, PL24,
PL36. 18, 24 and 36W respectively

Compliances:

AS2380

Electrical equipment for


explosive atmospheres - Flameproof
enclosure
AS2236 Electrical equipment for
explosive atmospheres - Dust excluding
Ignition proof
AS1939 Degrees of Protection IP66
Certificate of Compliance No. Ex933X

Options:

Emergency Exit Sign ........... NCE


Emergency Lighting Battery Pack
....................................................NC
Pole Mount ..............................PM
May 2003

Copyright 2003 Cooper Industries, Inc

Hazardous

Cat. No.

Area
5 Lighting

utilise the latest technology of compact


fluorescent lamps
Cast aluminium body with screw
threaded construction
Integral control gear in fully
accessible compartment
Stainless steel guard and reflector
Mounting feet facilitate mounting on
either wall or ceiling
Ease of installation
Reduced initial cost
Reduced maintenance cost
Can be supplied with special
Emergency Exit sign
Can be supplied with external
Emergency Battery Pack for 2 hours
standby lighting

Ordering Information:

5-16
Crouse-Hinds
NDFA
Heavy Duty
Fluorescent
Lighting Fixtures

Non-Sparking, Exn, IIC, IP66/67


Zone 2
Combustible Dust
Zone 21 & 22

Application:

For use in locations where a

concentration of flammable gases or


vapours may occur as the result of
an abnormal situation
Suitable for DIP locations such as
grain handling facilities or other
areas where hazardous dusts fibres
& flyings are present and may
become suspended in the
atmosphere or settle on equipment
or ledges
Ideal for walkways, bridges,
tunnels, security lighting, roadways
and process plants where reliable
lighting is required for safe operation
For arduous conditions or extreme
environments
Low profile for use in areas where
very low mounting heights or other
space restrictions make installation
difficult

Brass entry

5 Area
Lighting

Hazardous

Robust

Features:

diffuser clips

Three different mounting

arrangements available:
Ceiling mount
Pipe mount
Hanger mount
Corrosion resistant FRP housing
makes it ideal for installations in
areas where corrosive and / or wet
conditions exist during normal plant
operation
Noryl clips secure prismatic
diffuser to the body to ensure
reliable sealing while still allowing
ease of relamping and maintenance
A reliable seal between body and
diffuser is provided by a closed cell
non aging rubber gasket
Prismatic Diffuser eliminates glare
without diminishing the amount of
illuminance
Reflector / gear tray is suspended
on hangers for ease of installation
and maintenance

Standard Materials:

Body ......... Grey FRP (Fibreglass


reinforced polyester)
Prismatic Diffuser .......... Moulded
polycarbonate
Gasket ........... Polyurethane foam
Quick Release Clips .......... Noryl
Cable entry ........................Brass
May 2003

Standard Finishes:

Electrical Ratings:

Body .....................................Grey
Prismatic Diffuser ................ Clear

240 V, 50 Hz standard. Other


voltages and frequencies on request
18W, and 36W
Temperature rating....

Options:
(Refer to ordering information)
Through wiring ...... Terminal block
at each end of the fixture internally
wired (4mm2) to facilitate ease of
connection
Hanger Mounting ...... Eye Bolts
allow for suspension of the fixture by
either chain or steel cable
Pipe Mounting .. Brackets to allow
suspension from a pipe stanchion or
wall bracket
Emergency Lighting Pack .....
integral power pack to give 2 hours
standby lighting in the event of a
power supply failure
Non standard voltages
Stainless Steel quick-release clips
Other entries available upon
request

Exn - T3,

DIP - T5

Compliances:

Australian Standard 2238 Electrical


Equipment for explosive
atmospheres ............. Non-sparking
apparatus. Type of Protection n.
Certificate of Compliance Ex1153x
Australian Standard 2236 Electrical
Equipment for explosive
atmospheres ........... Dust-excluding
ignitionproof enclosure. Certificate of
Compliance Ex1149DIP
Australian Standard 1939 Degrees
of Protection of electrical equipment
IP66

Copyright 2003 Cooper Industries, Inc

5-17
Crouse-Hinds
Ordering Information

N D F A 1M 236 8 D M N S E
Voltage &
Frequency
1 - 110V / 60Hz
2 - 120V / 60Hz
3 - 220V / 50Hz
4 - 220V / 60Hz
5 - 230V / 50Hz
6 - 240V / 50Hz
8 - Electronic
Ballast - 220-245V /
47-63Hz

Product Identifier NDFA


Entry Size
1M- M20
2M- M25
1N - 1/2" NPT
2N - 3/4" NPT

Wattage
118 - 1x18
218 - 2x18
136 - 1x36
236 - 2x6

Cable Entries
0 - No through entry
T - Through entries
S - Single through entries
(2 entries on one side)
D - Double through entries
(2 entries on one side)

Emergency
0 - Standard
N - Emergency

Securing Clips
0 - Plastic
S - Stainless Steel

Exit Sign
0 - None
E - Exit Sign

Hazardous

Area
5 Lighting

Dimensions:
Lamp
A
Size
mm
18W 660
36W 1275

Types of Entry
P - Plastic
M - Metal

B
mm
550
800

Ceiling Mount Bracket

Mounting Accessories :

Photometric Data:

Lighting fixtures supplied complete


with ceiling mount brackets. Order pipe
clamps and eye bolts separately if
required. Two required per fixture.
Pipe Clamp
Pipe Diameter Height H
38-42mm
85mm
47-50mm
95mm
58-62mm
105mm

Cat No:
UN8-43
UN8-51
UN8-63

Eye bolt
Cat No. EBM6SS

C0

C90

cd/klm

Typical luminous flux of lamps


1 x 18 W = 1,350 Im, 2 x 18 W = 2,700 Im
1 x 36 W = 3,350 lm, 2 x 36 W = 6,700 lm

May 2003

Copyright 2003 Cooper Industries, Inc

5-18
Crouse-Hinds
nLLK
Heavy Duty
Fluorescent
Lighting Fixtures

Non-Sparking, Exn, IIC, IP66/67


Zone 2
Combustible Dust
Zone 21 & 22

Application:

For use in locations where a

concentration of flammable gases or


vapours may occur as the result of
an abnormal situation
Suitable for DIP locations such as
grain handling facilities or other
areas where hazardous dusts fibres
& flyings are present and may
become suspended in the
atmosphere or settle on equipment
or ledges
Ideal for walkways, bridges,
tunnels, security lighting, roadways
and process plants where reliable
lighting is required for safe operation
For arduous conditions or extreme
environments
Low profile for use in areas where
very low mounting heights or other
space restrictions make installation
difficult

5 Area
Lighting

Hazardous

Features:

Electronic ballast provides high

luminous efficiency, lower energy


consumption and longer service life
of the lamps
Emergency operation can be set
for 2 hour duration
Central locking system operated
by standard SW13 hex socket key
enables fixture to be opened from
one point of housing
Diffuser fastened by 10 and 20
latch points respectively on 18W
and 36W fixtures
Diffuser hinges from either side
and is also designed to act as a
convenient lamp support when open
to simplify lamp replacement

Standard Materials:

Body ......... Grey FRP (Fibreglass


reinforced polyester)
Diffuser .... Moulded
polycarbonate
Gasket ........... Polyurethane foam
Cable entry ........................Brass
Standard Finishes:

Options:

Compliances:

(Refer to ordering information)


Through wiring ...... Terminal block
at each end of the fixture internally
wired (4mm2) to facilitate ease of
connection
Hanger Mounting ...... Eye Bolts
allow for suspension of the fixture by
either chain or steel cable
Pipe Mounting .. Brackets to allow
suspension from a pipe stanchion or
wall bracket
Emergency Lighting Pack .....
integral power pack to give 2 hours
standby lighting in the event of a
power supply failure
Other entries available upon
request

Australian Standard 2238 Electrical

Equipment for explosive atmospheres


............. Non-sparking apparatus.
Type of Protection n.
Certificate of Compliance
- Aus Ex 3723
- PTB 98 ATEX 2208 (excluding Emergency Luminaires)
Australian Standard 1939 Degrees
of Protection of electrical equipment
IP66

Electrical Ratings:

240 V, 50 Hz standard. Other


voltages and frequencies on request
18W, and 36W
Temperature rating.
- Exn - T4

Body .....................................Grey
Prismatic Diffuser ................ Clear

May 2003

Copyright 2003 Cooper Industries, Inc

5-19
Crouse-Hinds
Ordering Information
& Dimensions

Ordering Information
Type.

Lamps

Temp Class
at 400C

Circuit

Catalogue
No.

2 x 18W
1 x 36W
2 x 36W
1 x 58W
2 x 58W

T4
T4
T4
T4
T4

Electronic
Electronic
Electronic
Electronic
Electronic

13465218021
13465136021
13465236021
13465158021
13465258021

2 x 18W
1 x 36W
2 x 36W

T4
T4
T4

Electronic
Electronic
Electronic

nLLK1M2188DMN00
nLLK1M1368DMN00
nLLK1M2368DMN00

Standard Fixtures
nLLK98018/18
nLLK98036
nLLK98036/36
nLLK98058
nLLK98058/58
Emergency Fixtures
nLLK98018/18N
nLLK98036N
nLLK98036/36N

Accessories
Type

Area
5 Lighting

2 2480 002 000


2 2480 092 000
UN8-43SP
UN8-51P

Hazardous

Galvanised Eyebolt A2
Stainless Steel Ceiling Bracket D92
Pipe Clamps 43mm
Pipe Clamps 51mm

Catalogue No.

Options
Type
Diffuser c/w EXIT Sign

Catalogue No.
Add E to Cat. No.

Dimensions

May 2003

Copyright 2003 Cooper Industries, Inc

5-20
Crouse-Hinds
AEVBH
Large Bulkhead
Luminaire

Flameproof, Exd, IIC, IP66


Zone 1
Combustible Dust
Zone 21 & 22

Application:

The AEVBH bulkhead luminaire is

suitable for use with HID, fluorescent


and incandescent light sources in
Zone 1 and Zone 21 & 22 hazardous
locations
Ideal for areas with low headroom or
mounting height where it allows the
use of energy efficient HID light
sources
For wall mounting in inspection pits
and similar wall mounting application
where the adjustable reflector allows
the light to be directed

Features:

Low profile (180mm) enables it to be


mounted in tight spots
Adjustable reflector allows direction
of light in specific directions
Available with a variety of light
sources including energy efficient
HPS
Reduced maintenance costs when
used with long-life HID light sources

5 Area
Lighting

Hazardous

Standard Materials:

Body and dome cover ...............


.................... Copper free aluminium
Diffuser ......................................
...... Heat and impact resistant glass
Guard ........... Stainless steel wire
Reflector .............. Stainless steel
Standard Finish:

Ordering Information:
Cat. No.
AEVBH 22201
AEVBH 42051
AEVBH 42071
AEVBH 42101
AEVBH 42151
AEVBH 52021
AEVBH 82051
AEVBH 82081
AEVBH 82101
AEVBH 82121
AEVBH 82171
AEVBH 92171

Lamp
Size
200W
50W
70W
100W
150W
2 x 11W
50W
80W
100W
125W
175W
175W

Lamp
Type
Incandescent
HPS
HPS
HPS
HPS
PL Fluorescent
Mercury Vapour
Mercury Vapour
Mercury Vapour
Mercury Vapour
Mercury Vapour
Metal Halide

Entry
Size
25mm
25mm
25mm
25mm
25mm
25mm
25mm
25mm
25mm
25mm
25mm
25mm

Temperature
Rating
T3
T4
T4
T4
T3
T6
T3
T3
T3
T3
T3
T3

Dimensions:

Grey polyurethane

Electrical Rating:

240V 50Hz
200W incandescent
175W mercury vapour
150W high pressure sodium
2 x 11W fluorescent
175W metal halide
Option:

Pipe mounting............ Add suffix J


Corro free powder polyester finish
.....................Information on request

Compliances:

AS2380 - Electrical equipment for

explosive atmospheres - Flameproof


enclosure
AS2236 - Electrical equipment for
explosive atmospheres - Dust
excluding ignition proof
AS1939 - Degrees of Protection
IP66
Certificate of Compliance No. Ex647

May 2003

Copyright 2003 Cooper Industries, Inc

5-21
Crouse-Hinds
EVM Hazard Gard
H.I.D. Lighting Fixtures
Integral Ballast
Factory Sealed

Flameproof, Exd, IIB or IIC, IP66


Zone 1
Combustible Dust
Zone 21 & 22

Application:
EVM Hazard Gard lighting fixtures
are used in
Hazardous areas, both indoors
and outdoors where long lamp life
and low maintenance costs are
desired
Heavy process industries having
environments where flammable or
explosive vapours or gases, or
where combustible dusts are
present

Features:

Fixture is factory wired; power is

fed through "wireless" connection


block which serves as a mechanical
seal between entry and ballast
compartment. The result is fast,
easy installation with improved
reliability and safety, enabling cost
effective installation and
maintenance
Dome and angle reflectors made
of Krydon - will not rust, corrode,
dent, chip or peel
High bay Alzak aluminum
reflectors are available for mounting
heights above 6m.
Uniform attractive appearance in
all wattages and mounting styles
Configurated glass reduces glare
improving light distribution
Certified for operation in elevated
ambient temperatures of up to 50oC
Wide range of light sources to
meet specific lighting needs - 80,
100, 125, 175, 250 & 400W mercury
vapour (MV); 175, 250 & 400W
metal halide (MH); 70, 100, 150,
250W, 400W high pressure sodium
(HPS)
Four mounting types to suit all
lighting layout ... pendant, ceiling,
wall bracket, and stanchion
Integral ballasts ... separate
ballasts are not required
Lowest installed cost

Area
5 Lighting

Hazardous

Standard Materials:

Mounting modules, cover, ballast

housing, guard, globe ring - copper


free aluminium
Glass ................. Heat and impact
resistant, configurated glass
Lamp socket .......... porcelain with
stainless steel screw shell
Reflectors ... dome and angle .......
fibreglass reinforced polyester
(Krydon); High Bay, Alzak
aluminium
External Hardware stainless steel

Electrical Ratings:
Standard Finishes:

Copper free aluminium ........ Grey


polyurethane
Krydon .................... natural white
Alzak ............... natural aluminium
Options
(Refer to ordering Information)
For Group IIC applications
Fuse .......... To protect ballast and
capacitors against line surges
May be ordered with or without
guard
Instant restrike ballast - enables a
hot HPS lamp to immediately
restrike after momentary loss of arc
due to voltage fluctuation or power
loss. Available for use with 50-150W
LX HPS only

240 VAC 50Hz


70 to 400 Watts
Alternate operating voltages

available, see ordering information

Entry Sizes:

20, 25mm hubs on ceiling, pendant

and wall mounted, 1 1/4


BSP on Stanchion Mount
Alternate entries available, see
ordering information

Compliances:

AS2380

Electrical equipment for


explosive atmospheres - Flameproof
enclosure
AS2236 - Electrical equipment for
explosive atmospheres. Dust
excluding ignition proof
AS1939 - Degrees of Protection
IP66
Certificate of Compliance No. Ex434

May 2003

Copyright 2003 Cooper Industries, Inc

5-22
Crouse-Hinds
Ordering Information

E V M A H 1 M 40 B 6 0 0 0 0
Product Identifier
EVMA - Pendant Mount
EVMB - Wall Mount
EVMC - Ceiling Mount
EVMJ - Stanchion Mount

Gas Group
B - Group IIB
C - Group IIC

5 Area
Lighting

Hazardous

Lamp Type
S - HPS
H - MV
M - MH

1
2
3
4

Entry Size
- 20mm / 1/2"
- 25mm / 3/4"
- 32mm / 1"
- 1 1/4 "

Entry Thread
M - Metric
N - 25mm / 3/4"
B - BPS

2
3
4
5
6

Voltage
& Frequency
- 120V/60Hz
- 220V/50Hz
- 220V/60Hz
- 230V/50Hz
- 240V/50Hz

Special Options
O - Standard
S - Fuse

May 2003

Wattage
07 - 70W
08 - 80W
10 - 100W
12 - 125W
15 - 150W
17 - 175W
25 - 250W
40 - 400W

Special Options
0 - Standard
1 - Special
Instant Restrike
0 - None
I - IR

Options
0 - Standard
1 - Offshore Paint

Copyright 2003 Cooper Industries, Inc

5-23
Crouse-Hinds
Ordering Information

Watts

Entry
Size

Pendant
With Guard
Cat. No.

Wall Bracket
With Guard
Cat. No.

Ceiling
WIth Guard
Cat. No.

EVMA81M08B60000
EVMA82M08B60000

EVMB81M08B60000
EVMB82M08B60000

EVMC81M08B60000
EVMC82M08B60000

EVMA82M10B60000
EVMA82M10B60000

EVMB81M10B60000
EVMB82M10B60000

EVMC81M10B60000
EVMC82M10B60000

EVMA81M12B60000
EVMA82M12B60000

EVMB81M12B60000
EVMB82M12B60000

EVMC81M12B60000
EVMC82M12B60000

EVMA81M17B60000
EVMA82M017B6000

EVMB81M17B60000
EVMB82M17B60000

EVMC81M17B60000
EVMC82M17B60000

EVMA81M25B60000
EVMA82M25B60000

EVMB81M25B60000
EVMB82M25B60000

EVMC81M25B60000
EVMC82M25B60000

EVMA81M40B60000
EVMA82M40B60000

EVMB81M40B60000
EVMB82M40B60000

EVMC81M40B60000
EVMC82M40B60000

Stanchion
With Guard
Cat. No.

Mercury Vapour - High Power Factor


80

100

125

175

250

400

20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP

EVMJ84B08B60000

EVMJ84B10B60000

EVMJ84B12B60000

EVMJ84B17B60000

EVMJ84B25B60000

EVMJ84B40B60000

100

150

250

400

20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP

EVMA41M07B60000
EVMA42M07B60000

EVMB41M07B60000
EVMB42M07B60000

EVMC41M07B60000
EVMC42M07B60000

EVMA41M10B60000
EVMA42M10B60000

EVMB41M10B60000
EVMB42M10B60000

EVMC41M10B60000
EVMC42M10B60000

EVMA41M15B60000
EVMA42M15B60000

EVMB41M15B60000
EVMB42M15B60000

EVMC41M15B60000
EVMC42M15B60000

EVMA41M25B60000
EVMA42M25B60000

EVMB41M25B60000
EVMB42M25B60000

EVMC41M25B60000
EVMC42M25B60000

EVMA41M40B60000
EVMA42M40B60000

EVMB41M40B60000
EVMB42M40B60000

EVMC41M40B60000
EVMC42M40B60000

EVMJ44B07B60000

EVMJ44B10B60000

EVMJ44B15B60000

EVMJ44B25B60000

EVMJ44B40B60000

Metal Halide - High Power Factor Ballast


175

250

400

20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP
20mm
25mm
1 1/4" BSP

EVMA91M17B60000
EVMA92M17B60000

EVMB91M17B60000
EVMB92M17B60000

EVMC91M17B60000
EVMC92M17B60000

EVMA91M25B60000
EVMA92M25B60000

EVMB91M25B60000
EVMB92M25B60000

EVMC91M25B60000
EVMC92M25B60000

EVMA91M40B60000
EVMA92M40B60000

EVMB91M40B60000
EVMB92M40B60000

EVMC91M40B60000
EVMC92M40B60000

EVMJ94B17B60000

EVMJ94B25B60000

EVMJ94B40B60000

Fixtures are supplied as standard suitable for 240/50 hz operation. For other voltages please specify required voltage.
Ceiling and bracket mounts have 4 hubs; 3 are plugged

May 2003

Copyright 2003 Cooper Industries, Inc

Hazardous

70

Area
5 Lighting

High Pressure Sodium - High Power Factor

5-24
Crouse-Hinds

5 Area
Lighting

Hazardous

Accessories

Dome Reflector
Cat.No. RD739

Lamp
Receptacle
Cat. No. EV62
All sizes

30 Angle Reflector
Cat.No. RA739

Ceiling Mount
Entry
Cat. No.
20mm
EV16
25mm
EV26

Glass Assembly
Watts
Cat. No.
Up to 175 EV7302
250/400
EV7404

Wall Mount
Entry
Cat. No.
20mm
EV16 + EV87
25mm
EV26 + EV87

Pendant Mount
Entry
Cat. No.
20mm
EVMP2
25mm
EVMP3

High Bay Reflector


Cat.No. EV3912

Guard
Watts
Cat. No.
Up to 175 EV503
250/400 EV5140

Stanchion Mount
Entry
Cat. No.
1 1/4" BSP
EVMJ4

Temperature Classification:
40oc Ambient
Power
Rating (W)
70
80
100
125
150
175
250
400

Mercury
Vapour (MV)
T6
T4
T4
T3
T3
T3

High Pressure
Sodium (HPS)
T6
T4
T4
T3
T3

Metal
Halide (MH)
T4
T3
T3

50oc Ambient
Power
Rating (W)
70
80
100
125
150
175
250
400

Mercury
Vapour (MV)
T6
T4
T4
T3
T3
T3

High Pressure
Sodium (HPS)
T6
T4
T4
T3
T3

Metal
Halide (MH)
T4
T3
T3

May 2003

Copyright 2003 Cooper Industries, Inc

5-25
Crouse-Hinds
Accessories

Wall Mount

Pendant Mount

Ceiling Mount

Stanchion Mount
Hazardous

Area
5 Lighting

80, 100, 125, 175, MV


70, 100, 150W HPS
175 MH

250W & 400W


MV, HPS, MH

All

Type

EVMA

553

610

499

564

618

EVMBX

635

693

581

646

697

EVMCX

553

610

499

564

618

EVMJ

543

594

573

May 2003

Copyright 2003 Cooper Industries, Inc

5-26
Crouse-Hinds
EVME Hazard Gard
H.I.D. Lighting Fixtures
Integral Ballast

Flameproof, Exde, IIB or IIC, IP66


Zone 1
Combustible Dust
Zone 21 & 22

Application:
EVME Hazard Gard lighting fixtures
are used in
Hazardous areas, both indoors
and outdoors where long lamp life
and low maintenance costs are
desired
Heavy process industry
environments where flammable or
explosive vapours or gases, or
combustible dusts are present

Features:

Indirect cable entry into a

separate Exe termination enclosure


ensures ease of installation
Dome and angle reflectors made
of Krydon - will not rust, corrode,
dent, chip or peel
High bay Alzak aluminium
reflectors are available for mounting
heights above 6m
Uniform attractive appearance in
all wattages and mounting styles
Configurated glass reduces glare
improving light distribution
Certified for operation in elevated
ambient temperatures of up to 50oC
Wide range of light sources to
meet specific lighting needs - 80,
100, 125, 175, 250 & 400W mercury
vapour (MV); 175, 250 & 400W
metal halide (MH); 70, 100, 150,
250W, 400W high pressure sodium
(HPS)
Standard ceiling mount luminaires
can be adapted for wall, pendant or
stanchion mount by using brackets
(order brackets seperatetly)
Integral ballasts ... separate
ballasts are not required
Lowest installed cost

5 Area
Lighting

Hazardous

Standard Materials:

Mounting modules, cover, ballast

housing, guard, globe ring - copper


free aluminium
Glass ................. Heat and impact
resistant, configurated glass
Lamp socket .......... porcelain with
stainless steel screw shell
Reflectors ... dome and angle .......
fibreglass reinforced polyester
(Krydon); High Bay, Alzak
aluminium
External Hardware stainless steel

Standard Finishes:

Entry Sizes:

20, 25mm hubs on ceiling, pendant

Copper free aluminium ........ Grey


polyurethane
Krydon .................... natural white
Alzak ............... natural aluminium

Options
(Refer to ordering Information)
For Group IIC applications
Fuse .......... To protect ballast and
capacitors against line surges

Instant restrike ballast - enables a

hot HPS lamp to immediately


restrike after momentary loss of arc
due to voltage fluctuation or power
loss. Available for use with 50-150W
LX HPS only
Alternate entries available please consult factory

and wall mounted, 1 1/4


BSP on Stanchion Mount
Alternate entries available, see
ordering information

Compliances:

EN50014

EN50018
EN50019
EN60529
EN60598
AS/NZS: 60079.0.2000
AS/NZS: 60079.1.2000
AS/NZS: 60079.7.2002

Certificate of Compliance No.


PTB ATEX1056
Aus EX Pending
Ambient Temperature
0
0
-50 to 55 C

Electrical Ratings:

240 VAC 50Hz


70 to 400 Watts
Alternate operating voltages

available, see ordering information

May 2003

Copyright 2003 Cooper Industries, Inc

5-27
Crouse-Hinds
Ordering Information

E V M E H 1 M 40 B 6 0 0 0 0
Product Identifiers

Gas Group
B - Group IIB
C - Group IIC
Lamp Type
S - HPS
H - MV
M - MH

Entry Thread
M - Metric
N - 25mm / 3/4"
B - BPS

2
3
4
5
6

Voltage
& Frequency
- 120V/60Hz
- 220V/50Hz
- 220V/60Hz
- 230V/50Hz
- 240V/50Hz

Special Options
O - Standard
S - Fuse

May 2003

Hazardous

Entry Size
- 20mm / 1/2"
- 25mm / 3/4"
- 32mm / 1"
- 1 1/4 "

Area
5 Lighting

1
2
3
4

Wattage
07 - 70W
08 - 80W
10 - 100W
12 - 125W
15 - 150W
17 - 175W
25 - 250W
40 - 400W

Special Options
0 - Standard
1 - Special
Instant Restrike
0 - None
I - IR

Options
0 - Standard
1 - Offshore Paint

Copyright 2003 Cooper Industries, Inc

5-28
Crouse-Hinds
Ordering Information

Mercury Vapour (M/V)


Wattage

T Rating

Cat No.

80W
100W
125W
175W
250W
400W

T6
T5
T4
T4
T3
T3

EVMEH1M08B60000
EVMEH1M10B60000
EVMEH1M12B60000
EVMEH1M17B60000
EVMEH1M25B60000
EVMEH1M40B60000

High Pressure Sodium (HPS)


Wattage

T Rating

Cat No.

70W
100W
150W
250W
400W

T6
T4
T4
T3
T3

EVMES1M07B60000
EVMES1M10B60000
EVMES1M15B60000
EVMES1M25B60000
EVMES1M40B60000

Wattage

T Rating

Cat No.

70W
100W
150W
175W
250W
400W

T6
T4
T4
T4
T3
T3

EVMEM1M07B60000
EVMEM1M10B60000
EVMEM1M15B60000
EVMEM1M17B60000
EVMEM1M25B60000
EVMEM1M40B60000

5 Area
Lighting

Hazardous

High Metal Halide (MH)

* Please refer to table for other possible configurations

Mounting Brackets (order seperately)


Pendant Mount

Cat No.

M20
M25
1/2" NPT Clearance Hole
3/4" NPT Clearance Hole

EVMEPM1
EVMEPM2
EVMEPN1
EVMEPN2

Wall Mount

Cat No.

M20 Thread
M25 Thread

EVMEWM1
EVMEWM2

Stanchion Mount

Cat No.

2" Slipfitter Pipe


1 1/4" BSP Thread
1 1/2" NPT Thread

EVMEJ
EVMEJB4
EVMEJN5

May 2003

Copyright 2003 Cooper Industries, Inc

5-29
Crouse-Hinds
Accessories

Wall Bracket
Cat No. EVMEW

30 Angle Reflector
Cat.No. RA739

Guard
Watts
Cat. No.
Up to 175
EV503
250/400
EV5140

Stanchion Bracket
Cat No. EVMEJ

High Bay Reflector


Cat.No. EV3912

May 2003

Watts
Up to 125
150 to 400

Lamp Holder
Cat. No.
EVMVS62600-SA
EVMVS12850-SA

Pendant Bracket
Cat No. EVMEP

Copyright 2003 Cooper Industries, Inc

Hazardous

Glass Assembly
Watts
Cat. No.
Up to 175 EV7302
250/400
EV7404

Area
5 Lighting

Dome Reflector
Cat.No. RD739

5-30
Crouse-Hinds

5 Area
Lighting

Hazardous

Dimensions

Wall Mount

Pendant Mount

Ceiling Mount

Stanchion Mount

May 2003

Copyright 2003 Cooper Industries, Inc

5-31
Crouse-Hinds
Fixture With Globe
and Without Guard

Fixture With Globe, Dome Reflector


and Without Guard

Lamp: 100W mercury vapour - (MV)


Total bare lamp lumens: 4200

Lamp: 100W mercury vapour - (MV)


Total bare lamp lumens: 4200

NOTE: Photometric data was developed using a 100 watt


diffuse mercury vapour lamp (4200 lumens). For other
diffuse lamps, use the following conversion factors
(multipliers): 175W MV - 2.05; 70W MH - 1.33;
100W MH - 1.85; 175W MH - 3.3.
Multipliers are for use with candela curve only.
Luminaire Spacing ratio is 1.30.

NOTE: Photometric data was developed using a 100 watt


diffuse mercury vapour lamp (4200 lumens). For other
diffuse lamps, use the following conversion factors
(multipliers): 175W MV - 2.05; 70W MH - 1.33;
100W MH - 1.85; 175W MH - 3.3.
Multipliers are for use with candela curve only.
Luminaire spacing ratio is 1.25.

Coefficient of Utilisation
Effective Floor Cavity Reflectance 20%

Coefficient of Utilisation
Effective Floor Cavity Reflectance 20%

4
.439
.361
.302

5
.386
.311
.253

% Reflectance
Eff.Ceil. Wall
50
80
30
10

Room Cavity Ratio


1
2
3
.715
.637
.570
.688
.596
.521
.655
.562
.483

4
.509
.455
.413

5
.458
.401
.359

70

50
30
10

.660
.615
.572

.556
.493
.441

.479
.410
.355

.418
.347
.291

.368
.297
.244

70

50
30
10

.699
.675
.652

.624
.586
.556

.560
.514
.478

.500
.450
.410

.448
.396
.356

50

50
30
10

.596
.559
.526

.501
.450
.405

.432
.375
.328

.377
.317
.270

.334
.274
.227

50

50
30
10

.668
.648
.631

.598
.568
.540

.539
.500
.468

.481
.438
.404

.434
.388
.353

30

50
30
10

.538
.509
.481

.451
.410
.373

.389
.342
.302

.339
.290
.249

.302
.250
.210

30

50
30
10

.640
.624
.609

.576
.550
.527

.519
.487
.459

.465
.428
.398

.420
.379
.348

10

50
30
10

.485
.461
.439

.405
.371
.341

.349
.310
.277

.305
.263
.228

.271
.223
.193

10

50
30
10

.615
.602
.589

.554
.553
.514

.502
.474
.450

.450
.418
.391

.407
.372
.343

.410

.313

.251

.204

.171

.575

.500

.436

.377

.329

Room Cavity Ratio


6
7
8
.347
.312
.282
.273
.241
.214
.220
.192
.165

9
.259
.192
.147

10
.230
.166
.125

% Reflectance
Eff.Ceil. Wall
50
80
30
10

Room Cavity Ratio


6
7
8
.414
.375
.340
.358
.319
.286
.318
.282
.247

9
.313
.259
.222

10
.275
.222
.187

% Reflectance
Eff.Ceil. Wall
50
80
30
10
70

50
30
10

.331
.262
.211

.298
.231
.184

.270
.206
.160

.248
.185
.143

.220
.162
.121

70

50
30
10

.407
.354
.315

.369
.315
.278

.335
.283
.246

.308
.256
.221

.271
.222
.187

50

50
30
10

.300
.241
.197

.272
.212
.171

.246
.190
.149

.227
.172
.134

.203
.150
.113

50

50
30
10

.394
.347
.312

.358
.309
.275

.325
.278
.244

.229
.252
.219

.264
.217
.185

30

50
30
10

.272
.222
.183

.245
.196
.158

.225
.175
.139

.207
.158
.124

.185
.138
.105

30

50
30
10

.383
.340
.308

.346
.304
.272

.316
.273
.242

.292
.248
.217

.257
.214
.183

10

50
30
10

.246
.202
.168

.224
.180
.147

.203
.160
.129

.188
.146
.115

.169
.127
.096

10

50
30
10

.371
.333
.304

.338
.299
.269

.307
.268
.240

.284
.244
.215

.251
.210
.181

.148

.128

.111

.099

.082

.292

.257

.227

.204

.170

May 2003

Copyright 2003 Cooper Industries, Inc

Hazardous

Room Cavity Ratio


1
2
3
.694
.584
.503
.644
.516
.428
.600
.459
.369

Area
5 Lighting

% Reflectance
Eff.Ceil. Wall
50
80
30
10

5 Area
Lighting

Hazardous

5-32
Crouse-Hinds
Isolux Chart: Fixture With Globe and
300 Angle Reflector, Without Guard

Fixture With Globe


and Without Guard

Lamp: 100W diffuse mercury vapour (MV)

Lamp: 150W high pressure sodium (HPS)

Total bare lamp lumens: 4,200

Total bare lamp lumens: 16,000

NOTE: Photometric data was developed using a 100 watt


diffuse mercury vapour lamp (4200 lumens). For other
diffuse lamps, use the following conversion factors
(multipliers): 175W MV - 2.05; 70W MH - 1.33;
100W MH - 1.85; 175W MH - 3.3.

NOTE: Photometric data was developed using a 150 watt


clear high pressure sodium lamp (16,000 lumens). For
other clear lamps, use the following conversion factors
(multipliers): 50W HPS - .25; 70W HPS - .40;
100W HPS - .59.
Multipliers are for use with candela curve only.
Luminaire spacing ratio is 0.80.

Illumination in footcandles on work plane 3m below light


centre. Multiply by factor shown to convert to other
mounting heights
Height (m)
1.8
2.1
2.4

Factor
2.78
2.04
1.56

Height (m) Factor


2.7
1.23
3.3
0.83
3.7
0.70

Coefficient of Utilisation
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff.Ceil. Wall
50
80
30
10

4
.410
.326
.262

5
.382
.305
.246

70

50
30
10

.659
.613
.570

.549
.484
.431

.469
.397
.341

.387
.311
.251

.363
.291
.236

50

50
30
10

.592
.555
.522

.491
.439
.393

.419
.360
.312

.344
.279
.229

.237
.265
.218

30

50
30
10

.531
.502
.474

.438
.396
.358

.373
.325
.284

.304
.250
.207

.292
.240
.200

10

50
30
10

.476
.451
.429

.390
.355
.325

.331
.291
.257

.267
.222
.184

.260
.217
.181

.399

.295

.230

.159

.159

Room Cavity Ratio


6
7
8
.342
.306
.278
.266
.234
.209
.212
.184
.160

9
.265
.198
.153

10
.233
.168
.127

% Reflectance
Eff.Ceil. Wall
50
80
30
10

May 2003

Room Cavity Ratio


1
2
3
.695
.579
.494
.644
.509
.417
.599
.450
.356

70

50
30
10

.324
.254
.202

.292
.223
.176

.265
.201
.155

.253
.191
.149

.222
.163
.123

50

50
30
10

.292
.232
.187

.263
.203
.162

.240
.184
.143

.231
.177
.139

.203
.150
.114

30

50
30
10

.262
.211
.172

.236
.186
.148

.218
.167
.132

.210
.162
.129

.185
.138
.105

10

50
30
10

.234
.190
.156

.213
.169
.135

.195
.152
.121

.191
.149
.118

.167
.125
.096

.135

.116

.103

.081

Copyright 2003 Cooper Industries, Inc

5-33
Crouse-Hinds
Fixture With Globe, Hi-Bay Reflector
and Without Guard

Fixture With Globe, Dome Reflector


and Without Guard

Lamp: 150W high pressure sodium - (HPS)


Total bare lamp lumens: 16,000

Lamp: 150W high pressure sodium - (HPS)


Total bare lamp lumens: 16,000

NOTE: Photometric data was developed using a 150 watt


clear high pressure sodium lamp (16000 lumens). For other
clear lamps, use the following conversion factors
(multipliers): 50W HPS - .25; 70W HPS - .40;
100W HPS - .59.
Multipliers are for use with candela curve only.
Luminaire spacing ratio is 1.00.

NOTE: Photometric data was developed using a 150 watt


clear high pressure sodium lamp (16000 lumens). For
other clear lamps, use the following conversion factors
(multipliers): 50W HPS - .25; 70W HPS - .40;
100W HPS - .59.
Multipliers are for use with candela curve only.
Luminaire spacing ratio is 1.00.

Coefficient of Utilisation
Effective Floor Cavity Reflectance 20%

Coefficient of Utilisation
Effective Floor Cavity Reflectance 20%
4
.531
.495
.468

5
.494
.455
.427

% Reflectance
Eff.Ceil. Wall
50
80
30
10

Room Cavity Ratio


1
2
3
.716
.637
.568
.689
.596
.519
.666
.561
.480

4
.507
.452
.410

5
.455
.398
.355

70

50
30
10

.655
.639
.525

.608
.583
.564

.566
.536
.513

.525
.491
.464

.487
.452
.425

70

50
30
10

.700
.675
.653

.624
.585
.555

.559
.512
.476

.498
.447
.407

.446
.393
.353

50

50
30
10

.629
.616
.606

.587
.568
.550

.550
.525
.505

.511
.482
.459

.476
.446
.422

50

50
30
10

.668
.648
.631

.598
.567
.539

.538
.498
.466

.479
.435
.400

.432
.385
.349

30

50
30
10

.606
.597
.588

.569
.554
.539

.535
.514
.497

.498
.474
.454

.466
.438
.418

30

50
30
10

.640
.625
.610

.575
.549
.526

.518
.485
.457

.463
.425
.394

.417
.376
.344

10

50
30
10

.586
.578
.570

.533
.539
.528

.522
.504
.489

.487
.466
.449

.457
.433
.413

10

50
30
10

.615
.602
.590

.554
.532
.513

.500
.472
.448

.447
.415
.388

.404
.369
.339

.560

.517

.479

.439

.404

.575

.498

.434

.373

.326

Room Cavity Ratio


6
7
8
.460
.427
.396
.420
.388
.358
.394
.361
.330

9
.369
.330
.303

10
.328
.288
.262

% Reflectance
Eff.Ceil. Wall
50
80
30
10

Room Cavity Ratio


6
7
8
.413
.373
.339
.355
.318
.285
.316
.280
.246

9
.312
.258
.221

10
.275
.222
.187

% Reflectance
Eff.Ceil. Wall
50
80
30
10
70

50
30
10

.455
.418
.391

.423
.385
.359

.392
.356
.329

.366
.328
.303

.325
.288
.262

70

50
30
10

.405
.352
.312

.368
.314
.277

.334
.283
.245

.308
.256
.221

.271
.222
.187

50

50
30
10

.444
.412
.388

.414
.380
.357

.385
.352
.328

.360
.325
.301

.320
.285
.261

50

50
30
10

.392
.345
.309

.356
.307
.274

.324
.277
.243

.299
.252
.219

.264
.217
.185

30

50
30
10

.436
.407
.385

.406
.377
.354

.379
.348
.326

.354
.322
.300

.315
.282
.259

30

50
30
10

.380
.338
.306

.345
.303
.270

.316
.272
.241

.291
.247
.217

.257
.214
.183

10

50
30
10

.428
.402
.382

.400
.373
.352

.373
.345
.324

.348
.319
.298

.311
.280
.258

10

50
30
10

.369
.331
.301

.337
.298
.267

.307
.267
.238

.283
.244
.215

.251
.210
.181

.373

.343

.315

.290

.249

.292

.257

.227

.204

.170

May 2003

Copyright 2003 Cooper Industries, Inc

Hazardous

Room Cavity Ratio


1
2
3
.688
.618
.573
.651
.592
.542
.636
.569
.517

Area
5 Lighting

% Reflectance
Eff.Ceil. Wall
50
80
30
10

5-34
Crouse-Hinds
NVMV Champ
HID Lighting Fixtures
Integral Ballast

Non-Sparking, ExnR, IIC, IP66


Zone 2
Combustible Dust
Zone 21 & 22

Application:

Used in locations where a

concentration of hazardous gases


liquids or vapours may occur for
short periods of time at infrequent
intervals
Used in hazardous locations where
combustible dusts, fibres or flyings
may be present
Used where maintenance access
is difficult and extended periods
between relamping is required
Ideal for processing plants, waste
and sewage treatment facilities
security lighting, roadways, garages
& other heavy industrial applications
Used where space is limited and
high levels of lighting are required

Features:
All Units:
Several mounting arrangements:
Pendant
Ceiling for flush to surface mounting
Wall bracket-through feed
Stanchion - 25 angle
Integral long-life ballast
Choice of light source - mercury
vapour (MV), high pressure sodium
(HPS) or metal halide
Operating ambient temperature
between minus 45C and 55
Attractive gray polyurethane paint
finish
Configured glass and prismatic
refractors reduce glare and improve
light distribution
Recessed hubs
Restricted breathing design gives
improved T Rating allowing use of
higher lumen output fixtures
Special Exn terminals to ensure
positive connection to circuit wiring

5 Area
Lighting

Hazardous

Ceiling mount with dome reflector

Standard Finishes:

Aluminium ballast housings,

Electrical Rating:

Compliances:

Options:

Standard Materials:

Ballast housings and mountings

copper free aluminium


(less than 0.4 of 1%)
Guards - copper free aluminium or
stainless steel wire
Exterior hardware - stainless steel
Globes - configurated glass
Reflectors - dome or angle white
Krydon fibreglass - reinforced
polyester material
Reflector lens assy - Alzak
aluminium reflector, tempered glass
lens

May 2003

mountings and aluminium guards


............ grey polyurethane paint
Stainless steel wire guards
............................ natural
Reflectors .......................... natural

(Refer to ordering information)


Corro-free powder polyester
coating, information available on
request
Quartz auxiliary lamp to provide
light during the period required for
HID lamps to restrike following
resumption of power after a power
failure - Large body fixtures only
Instant restrike ballast - enables a
hot HPS lamp to immediately restrike
after a momentary loss of arc due to
voltage fluctuation or power outage. It
has no effect on the warm-up period
of cold lamps. Available for use with
50-150W HPS LX only
Large body for improved T Rating
on 250 Watt fixtures
For application subject to extreme
thermal shock, Tuff-skin coated G34
and G251 glasses are available
Non-standard supply voltage and
frequency, consult factory
Fuse - to protect against abnormal
line conditions and provide additional
circuit protection
Other entries available upon request

240V 50Hz
70 to 400W
P.F. 0.9
AS2380

Electrical equipment for


explosive atmospheres - NonSparking Equipment, & Dust
Excluding Ignition Proof
AS 1939 ... Degrees of protection
IP66
EN50021:1999
Certificate of Compliance No.
- Ex426
- PTB00 ATEX 2215

Dimensions:

See Pages 6-8 to 6-9


Photometric Data:

See Pages 6-10 to 6-13


Accessories:

See Page 5-38

Copyright 2003 Cooper Industries, Inc

5-35
Crouse-Hinds
Ordering Information

NVMV S 1 M C 40 6 P I 0 0
Product Group
NVMV- Champ

Wattage
07 - 70W
08 - 80W
10 - 100W
12 - 125W
15 - 150W
17 - 175W
25 - 250W
40 - 400W

Lamp Type
S - HPS
H - MV
M - MH

Entry Thread
M - Metric
N - NPT
B - BSP

2
3
4
5
6

Voltage
& Frequency
- 120V / 60Hz
- 220V / 50Hz
- 220V / 60Hz
- 230V / 50Hz
- 240V / 50Hz

Special Options
0 - Standard
S - Fuse

May 2003

Mounting
C - Ceiling
W - Wall
J - Stanchion

Hazardous

Entry Size
- 20mm / 1/2"
- 25mm / 3/4"
- 32mm / 1"
- 1 1/4"
- 1 1/2"

Area
5 Lighting

1
2
3
4
5

Guard
0 - Without Guard
P - Guard
R - RD4A
Instant Restrike
0 - None / Small Body
I - IR
L - Large Body

Options
0 - Standard
1 - Offshore Paint
R - Red Body

Copyright 2003 Cooper Industries, Inc

5-36
Crouse-Hinds
Ordering Information

Large body ceiling mount with


RD4A reflector lens assembly

Mercury Vapour (M/V) 240V/50Hz*


High power factor reactor ballast (.9)

5 Area
Lighting

Hazardous

Entry
Size

Lamp
Watts

With Glass and Guard


Cat. No.

With Reflector Lens Assy.


Cat. No.

Ceiling/Pendant Mount
20mm
80
25mm
80
20mm
100
25mm
100
20mm
125
25mm
125
20mm
175
25mm
175
20mm
250
25mm
250
20mm
400
25mm
400

NVMVH1MC086P000
NVMVH2MC086P000
NVMVH1MC106P000
NVMVH2MC106P000
NVMVH1MC126P000
NVMVH2MC126P000
NVMVH1MC176P000
NVMVH2MC176P000
NVMVH1MC256P000
NVMVH2MC256P000
NVMVH1MC406PL00
NVMVH2MC406PL00

Wall Mount
20mm
25mm
20mm
25mm
20mm
25mm
20mm
25mm
20mm
25mm
20mm
25mm

NVMVH1MW086P000
NVMVH2MW086P000
NVMVH1MW106P000
NVMVH2MW106P000
NVMVH1MW126P000
NVMVH2MW126P000
NVMVH1MW176P000
NVMVH1MW176P000
NVMVH1MW256P000
NVMVH2MW256P000
NVMVH1MW406PL00
NVMVH2MW406PL00

NVMVH1MW256RL00
NVMVH2MW256RL00
NVMVH1MW406RL00
NVMVH2MW406RL00

NVMVH4BJ086P000
NVMVH4BJ106P000
NVMVH4BJ126P000
NVMVH4BJ176P000
NVMVH4BJ256P000
NVMVH4BJ406PL00

80
80
100
100
125
125
175
175
250
250
400
400

Stanchion Mount
1 1/4" BSP 80
1 1/4" BSP 100
1 1/4" BSP 125
1 1/4" BSP 175
1 1/4" BSP 250
1 1/4" BSP 400

May 2003

NVMVH1MC256RL00
NVMVH2MC256RL00
NVMVH1MC406RL00
NVMVH2MC406RL00

Copyright 2003 Cooper Industries, Inc

5-37
Crouse-Hinds
Ordering Information
High Pressure Sodium (HPS) 240V/50Hz*
High power factor reactor ballast (.9) with solid state ignitor
With Reflector
& Lens Assy.
Cat. No.

NVMVS1MC076P000
NVMVS2MC076P000
NVMVS1MC106P000
NVMVS1MC106P000
NVMVS1MC156P000
NVMVS2MC156P000
NVMVS1MC256P000
NHMVS2MC256P000
NVMVS1MC406PL00
NVMVS2MC406PL00

NVMVS1MC256RL00
NVMVS2MC256RL00
NVMVS1MC406RL00
NVMVS2MC406RL00

NVMVS1MW076P000
NVMVS2MW076P000
NVMVS1MW106P000
NVMVS2MW106P000
NVMVS1MW156P000
NVMVS2MW156P000
NVMVS1MW256P000
NVMVS2MW256P000
NVMVS1MW406PL00
NVMVS2MW406PL00

NVMVS1MW256RL00
NVMVS2MW256RL00
NVMVS1MW406RL00
NVMVS2MW406RL00

NVMVS4BJ076P000
NVMVS4BJ106P000
NVMVS4BJ156P000
NVMVS4BJ256P000
NVMVS4BJ406PL00

NVMVS4BJ256RL00
NVMVS4BJ406RL00

Metal Halide (MH)


High power factor reactor ballast (.9) with solid state ignitor
Ceiling / Pendant Mount
20mm
175
25mm
175
20mm
250
25mm
250
20mm
400
25mm
400
Wall Mount
20mm
175
25mm
175
20mm
250
25mm
250
20mm
400
25mm
400
Stanchion Mount
1 1/4" BSP
175
1 1/4" BSP
250
1 1/4" BSP
400

NVMVM1MC176P000
NVMVM2MC176P000
NVMVM2MC256P000
NVMVM2MC256P000
NVMVM2MC406PL00
NVMVM2MC406PL00

NVMVM1MC256RL00
NVMVM1MC256RL00
NVMVM1MC406RL00
NVMVM1MC406RL00

NVMVM1MW176P000
NVMVM1MW176P000
NVMVM1MW256P000
NVMVM1MW256P000
NVMVM1MW406PL00
NVMVM1MW406PL00

NVMVM1MW256RL00
NVMVM1MW256RL00
NVMVM1MW406RL00
NVMVM1MW406RL00

NVMVM4BJ176P000
NVMVM4BJ176P000
NVMVM4BJ176PL00

NVMVM4BJ256RL00
NVMVM4BJ406RL00

Please refer to page 5-30 for other configurations


May 2003

Copyright 2003 Cooper Industries, Inc

Hazardous

With Glass
And Guard
Cat. No.

Area
5 Lighting

Entry
Lamp
Size
Watts
Ceiling / Pendant Mount
20mm
70
25mm
70
20mm
100
25mm
100
20mm
150
25mm
150
20mm
250
25mm
250
20mm
400
25mm
400
Wall Mount
20mm
70
25mm
70
20mm
100
25mm
100
20mm
150
25mm
150
20mm
250
25mm
250
20mm
400
25mm
400
Stanchion Mount
1 1/4" BSP
70
1 1/4" BSP
100
1 1/4" BSP
150
1 1/4" BSP
250
1 1/4" BSP
400

5-38
Crouse-Hinds
Accessories
GLASSES
Lamp Fixture
Size
70-250W

400W

Configured
Glass
Cat. No.
G34
(No Guard)
G251
(With Guard)
G303

Type
Heat
Resistant
Heat
Resistant
Heat
Resistant

REFLECTORS
Lamp
Size
70-250W
400W
(Large Body)

Cat. No.
RD70
RA70

Type
Dome
30 Angle

RD739
RA739

Dome
30 Angle

REFLECTOR/LENS

Hazardous

Lamp
Size
400W

Cat. No.
RD4A

5 Area
Lighting

GUARDS
Lamp
Size
70-250W
250W (Large Body)
400W

Suits Glass
Cat No.
G251
G303
G303

Guard.
Cat No.
P22
P33
P33

Temperature Classification:
Power
Rating (W)
70
80
100
125
150
175 (small body)
175 (large body)
250 (small body)
250 (large body)
400
400 (using sealed
reflector/glass RD4A)

Mercury
Vapour (MV)
G34 G303 G251
T4
T4
T4
T4
T4
T3
T3
T3
T3

T2
T3
T2
T3

High Pressure
Sodium (HPS)
G34 G303 G251
T5
T5
T4
T3
T4
T3
T4
T3
T2
T3
T3
T4

Metal
Halide (MH)
G34 G303 G251
T3
T3
T3

T2
T3
T2
T3

Note: Light fixtures up to 250W use small body.


400W fixtures use large body
250W can be supplied in large body to give improved T rating - Please refer to table on
May 2003

Copyright 2003 Cooper Industries, Inc

5-39
Crouse-Hinds
NFMV
Industrial
Floodlight
Luminaires

Non-Sparking, Exn R, IIC, IP66


Zone 2
Combustible Dust
Zone 21 & 22

Application:
NFMV floodlights are suitable for use in:
Outdoor locations such as those
found in process plants,
manufacturing plants, loading and
storage areas, petrochemical, waster
or sewerage treatment plants

Features:

Enclosed and gasketed for


wet locations
Choice of HID light sources

including HPS; 70, 100, 150,


250, & 400 MV; 175, 250 &
400 MH;175, 250 & 400
Versatile yoke mounting
bracket simplifies installation
Slipfitter adaptor
available for 2 pole top
mounting
Door frame is hinged
and has captive
fastening screws for
ease of relamping
Silicone rubber
gaskets are standard,
ensuring long life and
reliable environmental
sealing even under
adverse conditions
Die cast aluminium
exterior components are
epoxy powder coated for
superior corrosion resistance
Corrosion resistant stainless
steel external hardware

NFMV showing SFA6


slipfitter adaptor and gland
(order separately)

Hazardous

Area
5 Lighting

Standard Materials:

Housing and door frame


............................die cast aluminium
Lens ... tempered heat and impact
resistant glass
Gasket .............. extruded silicone
Exterior hardware .......... stainless
steel

Standard Finishes:

Grey epoxy powder coated

Ordering Information:
Cat No.
Mercury Vapour
NFMVH1MY4060000
NFMVH1MY2560000
NFMVH1MY1760000

NFMVS1MY4060000
NFMVS1MY2560000
NFMVS1MY1560000
NFMVS1MY1060000
NFMVS1MY0760000
Metal Halide

240 50Hz
70 to 400 watts
Other voltages and frequencies

NFMVM1MY4060000
NFMVM1MY2560000
NFMVM1MY1760000

Compliances:

Mounting Accessory

AS2380.9 Exn
AS 2236... 1994 DIP
EN50021
Certificate of Compliance No.

400W
250W
175W

MV
MV
MV

T3
T4
T5
T5
T6

400W
250W
150W
100W
70W

HPS
HPS
HPS
HPS
HPS

T3
T4
T4

400W
250W
175W

MH
MH
MH

High Pressure Sodium

Electrical Rating:

available on request

T3
T3
T4

Slipfitter
SFA6 - M20
SFA6 / 2M - M25

- Aus Ex 3562
- PTB 00 Atex 2214
May 2003

Copyright 2003 Cooper Industries, Inc

5-40
Crouse-Hinds
Ordering Information

NFMV S 1 M Y 40 6 0 0 0 0
Product Group
NFMV - Floodlight

Wattage
07 - 70W
08 - 80W
10 - 100W
12 - 125W
15 - 150W
17 - 175W
25 - 250W
40 - 400W

5 Area
Lighting

Hazardous

Lamp Type
S - HPS
H - MV
M - MH

1
2
3
4
5

Entry Size
- 20mm / 1/2"
- 25mm / 3/4"
- 32mm / 1"
- 1 1/4"
- 1 1/2"

Entry Thread
M - Metric
N - NPT
B - BSP

1
2
3
4
5
6
7

Voltage
& Frequency
- 110V / 60Hz
- 120V / 60Hz
- 220V / 50Hz
- 220V / 60Hz
- 230V / 50Hz
- 240V / 50Hz
- 227V / 60Hz

Special Options
0 - Standard
S - Fused

May 2003

Mounting
C - Ceiling
W - Wall
J - Stanchion

0 - NFMV

Instant Restrike
0 - None
I - IR

Options
0 - Standard
1 - Offshore Paint
R - Red Body

Copyright 2003 Cooper Industries, Inc

5-41
Crouse-Hinds

Lamp: 400W metal halide (M / H)


Total bare lamp lumens: 34,000

Lamp: 400W high pressure sodium (HPS)


Total bare lamp lumens: 50,000

For 250 watt clear metal halide,


multiply lux values by 0.6

For 150 watt HPS, multiply lux by 0.32. For 250 watt
high pressure sodium, multiply lux values by 0.6

Ratio of Distance to
Mounting Height

Ratio of Distance to
Mounting Height

Photometric Data
& Dimensions

Ratio of Distance to Mounting Feet

Ratio of Distance to Mounting Feet

Isolux Values at Various Mounting Heights


(Lux values for both charts)
C
21.52
11.84
7.53
5.38
4.30
3.23

D
8.61
5.38
3.23
2.15
1.61
1.18

E
4.30
2.47
1.51
1.08
0.75
0.65

Fixture aiming angle 300 past vertical


through 600 before vertical
EPA Data - Aiming Angle
00 = 2.9
300 = 2.5
450 = 2.5

Dimensions (mm)
430

175

65

45
0

660

20mm Entry

May 2003

390

530

10
12
0

Mo 2 Ho
le
un
tin s
g D 15
eta
ils

Copyright 2003 Cooper Industries, Inc

Hazardous

B
43.0
24.75
15.06
10.76
7.53
6.46

Fixtures located at 00, 00


Aiming angle at 450
Area
5 Lighting

Mounting
Height
A
5m
86.0
6m
18.42
7m
31.20
9m
21.52
11m
16.14
12m
11.84

5-42
Crouse-Hinds
FSFB 301
Flashing
Beacon

Flameproof, Exd, IIC, IP66


Zone 1
Combustible Dust
Zone 21 & 22

Application:
The FSFB flashing beacon can be
used as:
as an obstruction marker
as a visual alarm signal
in areas which may be hazardous
due to the presence of flammable
liquids, gases or vapours,and dusts

Features:

Solid state beacon means no moving


parts to wear out or fail
Flametight threaded joints
O-ring gaskets for weatherproofing
Lightweight, copper free aluminium
principal parts
Easy to assemble
Standard Materials:

Body ..... Copper free cast aluminium


Dome ................. Heat and impact
resistant glass
Beacon ......Solid state strobe light

5 Area
Lighting

Hazardous

Standard Finish:

Grey polyurethane
Options:

Cast aluminium guard


.........................Cat. No. EV505
Special paint or protective finishes
.............................. specify
Other colours: Clear, Green, Blue,
Amber. Add C, G, B or A to Cat. No.
when ordering
Pendant entry ..... specify size &
thread form

Dimensions:

Compliances:

AS2480

Electrical equipment for


explosive atmospheres - Flameproof
enclosure
AS2236 - Electrical equipment for
explosive atmospheres. Dust excluding
Ignition - proof
AS1939 - Degrees of Protection
IP65
Certificate of Compliance No. Ex491

Ordering Information:

FSFB201 / Voltage

/ Colour
Example FSFB20124R = 24 Volt red

Technical Data:
24V DC
Supply
240V AC
Flash
Rate
60 FPM

Light Output 2.25 Joules per flash


Conduit Entries 2 x 20mm
(1 Plugged)

May 2003

Copyright 2003 Cooper Industries, Inc

5-43
Crouse-Hinds
FRFB 301
Rotating
Beacon

Flameproof, Exd, IIC, IP66


Zone 1
Combustible Dust
Zone 21 & 22

Application:
The FRFB rotating beacon can be
used as:
as an obstruction marker
as a visual alarm signal
in areas which may be hazardous
due to the presence of flammable
liquids, gases or vapours, and dusts

Features:

Flametight threaded joints


O-ring gaskets for weatherproofing
Lightweight, copper free aluminium
principal parts
Easy to assemble
Standard Materials:

Body .. Copper free cast aluminium


Dome ................. Heat and impact
resistant glass - red
Beacon ..........................Lamp size

Hazardous

Area
5 Lighting

70 W quartz Halogen / 24V DC


55W quartz Halogen / 12V DC
25W incandescent / 240V AC
Add 12, 24 or 240 to Cat. No. when
ordering

Standard Finish:

Grey polyurethane
Options:

Cast aluminium guard


.........................Cat. No. EV505
Special paint or protective finishes
.............................. specify
Other dome colours: Clear, Green,

Blue, Amber. Add C, G, B or A to Cat.


No. when ordering
Pendant entry ..... specify size &
thread form

Dimensions:

Compliances:

AS2480 - Electrical equipment for

explosive atmospheres - Flameproof


enclosure
AS2236 - Electrical equipment for
explosive atmospheres. Dust excluding
Ignition - proof
AS1939 - Degrees of Protection IP65
Certificate of Compliance No. Ex491

Technical Data:
12/24V DC
Supply
240V 50HZ AC
Flash Rate 150 RPM
Conduit Entries 2 x 20mm
(1 Plugged)

Ordering Information:

FRFB301 / Voltage / Colour

Example FRFB30124R = 24 Volt red


May 2003

Copyright 2003 Cooper Industries, Inc

5 Area
Lighting

Hazardous

5-44
Crouse-Hinds

May 2003

Copyright 2003 Cooper Industries, Inc

Você também pode gostar