DPCE-28.SMART
NEW
6...9
cable
27
Delta Contr
Delta Contr
Delta Contr
PRODUK A
PRODUK A
PRZETWC
Numer fabr
Zakres pom
Sygnal wyh
Zasilanie
PRZETWC
Numer fabr
Zakres pom
Sygnal wyh
Zasilanie
PD type electrical
connection, IP-65
Connector DIN 43650
120
103
114
5...10
cable
PRODUK A
27
PRZETWC
Numer fabr
Zakres pom
Sygnal wyh
Zasilanie
PZ type electrical
connection, IP-66
PM12 type
electrical connection, IP-67
1/2NPT
PRODUK A
PRZETWC
Numer fabr
Zakres pom
Sygnal wyh
Zasilanie
SW27
SG type electrical
connection, IP-68
Length of cable: according to
client specification.
Delta Contr
PRODUK A
PRZETWC
Numer fabr
Zakres pom
Sygnal wyh
Zasilanie
SW27
SW27
2 8
NEW
20
15
SW27
132
Delta Contr
132
NEW
G1/4
12
1/2NPT
25
25
G1/2 type
G1/2", 4 hole
M type
1/2NPT type
GP type
1/2NPT male +
internal thread G1/4
G1/2", 12 hole
1/2NPT F type
internal thread 1/2-14NPT
P type
M201.5, 4 hole
M201.5, 12 hole
1/4NPT F type
internal thread 1/4-18NPT
SW41
10
15
31
2 10
10.5
SW32
30
O-ring
26 2
35
CG1 type
12
25
CM302 type
M302 with flush
diaphragm
Application
DPCE-28.SMART pressure transmitter is applicable to the measurement of the pressure, underpressure and absolute
pressure of gases, vapours and liquids. The active sensing element is a piezoresistant silicon sensor separated from the
medium by a diaphragm and by specially selected type of manometric liquid.
Communication
The communication standard for data interchange with the
transmitter is the HART protocol.
Communication with the transmitter is carried out with:
o a KAP-03 communicator,
o some other Hart type communicators,
o a PC using an RS-HART converter and RAPORT 2 configuration software.
The data interchange with the transmitter enables the users
to:
o identify the transmitter;
Installation
The transmitter is not heavy, so it can be installed on the installation without additional mounting bracket. When the pressure of
steam or other hot media is measured, a siphon or impulse line should be used. The needle valve placed upstream the transmitter
simplifies installation process and enables the zero point adjustment or the transmitter replacement. The transmitters electrical
connections should be performed with twisted cable. The place for the communicator should be assigned before the communicator
installation.
Measuring ranges
No.
1
10 bar
(1MPa)
100:1
Overpressure limit
(without hysteresis)**
1200 bar
(120 MPa)
0..300 bar
(0..30 MPa)
3 bar
(300 kPa)
100:1
450 bar
(45 MPa)
0..160 bar
(0..16 MPa)
1,6 bar
(160 kPa)
100:1
450 bar
(45 MPa)
4
5
6
0...70 bar
0...25 bar
0...7 bar
(0...7 MPa)
(0...2.5 MPa)
(0...0.7 MPa)
0.7 bar
0.25 bar
0.07 bar
(70 kPa)
(25 kPa)
(7 kPa)
100:1
100:1
100:1
140 bar
50 bar
14 bar
(14 MPa)
(5 MPa)
(1.4 MPa)
-1...6 bar
0...2 bar
0...1 bar
-0.5...0.5 bar
0...0.25 bar
-100...100 mbar
-15...70 mbar
0...1.3 bar abs
0...7 bar abs
0...25 bar abs
0...70 bar abs
(-100...600kPa)
(0...200 kPa)
(0...100 kPa)
(-50...50 kPa)
(0...25 kPa)
(-10...10 kPa)
(-1.5...7 kPa)
(0...130 kPa abs)
(0...0,7 MPa abs)
(0...2.5 MPa abs)
(0...7 MPa abs)
300mbar
100 mbar
50 mbar
50 mbar
25 mbar
20 mbar
5 mbar
100 mbar abs
0.07 bar abs
0.25 bar abs
0.7 bar abs
(30 kPa)
(10 kPa)
(5 kPa)
(5 kPa)
(2.5 kPa)
(2 kPa)
(0.5 kPa)
(10 kPa abs)
(7 kPa abs)
(25 kPa abs)
(70 kPa abs)
23:1
20:1
20:1
20:1
10:1
10:1
17:1
13:1
100:1
100:1
100:1
14 bar
4 bar
2 bar
2 bar
1 bar
1 bar
0.5 bar
2 bar
14 bar
50 bar
140 bar
(1.4 MPa)
(400 kPa)
(200 kPa)
(200 kPa)
(100 kPa)
(100 kPa)
(50 k Pa)
(200 kPa)
(1.4 MPa)
(5 MPa)
(14 MPa)
7
8
9
10
11
12
13
14
15
16
17
Rangeability
Technical data
Metrological parameters
Accur acy
0.1% of calibrated range
Long-ter m stability
accuracy for 3 years
(for the basic range)
Therm al error < 0.08% (FSO) / 10C
(0.1% for ranges 12, 13)
max. 0.25% (FSO) in the whole compensation range
(0.4% for ranges 12, 13)
Therm al compensation range
-25...80C
-40...80C special vers ion
Time Constant
16..230ms(programmable)
Additional electronic damping
Er ror due to supply voltage changes
0...30 s
0.002% (FSO) / V
Electrical parameters
Power supply
Output signal
Load resistance
Materials
Wetted parts and diaphragms: 316Lss, Hastelloy C 276, Au
Casing:
304ss
Optional: 316ss
Operating conditions
Operating temperature range (ambient temp.)
-40...85C
EEx version
-4065C
-40...120C
240...1100
13
Ordering Procedure
Model
Code
Description
DPCE-28.SMART
Versions,
certificates*
/Exia....................................
/Tlen................................... For oxygen service(sensor filled with Fluorolube fluid, only M,G1/2 pr. conn.)
/-40+80C...........................................
**)
non-standard ranges available on request
Measuring set range
01000bar ( 0100MPa)
0300bar ( 030MPa)
0160bar ( 016MPa)
070bar ( 07MPa)
0.25bar ( 02,5MPa)
07bar ( 0700KPa)
02bar ( 0200kPa)
01bar ( 0100kPa)
00,25bar ( 025kPa)
-0,50,5bar ( -5050kPa)
-16bar ( -100600kPa)
-100100mbar ( -1010kPa)
-1570mbar ( -1,57kPa)
01.3bar absolute pressure (0130kPa abs)
07bar absolute pressure ( 0700kPa abs)
025bar absolute pressure ( 02.5MPa abs)
070bar absolute pressure ( 07MPa abs)
/PD..........
/PZ.........................
/PZ/316..................
/PM12................................
/SG ....................................
/SGM...................................
Start and end of calibrated range in relation to 4mA and 20mA output
Casing,
Electrical connection,
/01000bar..........................
/0300bar............................
/0160bar**......................
/070bar.......................
/025bar.......................
/07bar.....................
/02bar............................
/01bar.....................
/00,25bar...........................
/-0.5 +0.5bar.........................
/-16bar..................................
/-100100mbar.......................
/-1570mbar........................
/01.3bar ABS.......................
/07barABS.........................
/025barABS..........................
/070bar ABS.........................
/P............................
/P. (Hastelloy).................
/GP.....................
/GP (Hastelloy)..............
/CM30x2........................
Process connections
Example : Pressure transmitter , output 4..20mA + HART, version EExia, nominal measuring range 0..7bar, calibrated range 0..6bar,
process connection NPT male, electrical connection DIN43650 connector.
DPCE-28.SMART/EExia/0..7bar/0..6bar/PD/1/2NPTM
14