Você está na página 1de 4

Universidad Politcnica Salesiana-Sede Cuenca.

Practica #3: RELACIN DE


TRANSFORMACIN Y POLARIDAD
Criollo Boris, Gonzlez Anbal, Legarda Cristian, Sancho Patricio, Sigcha Felix
bcriolloe@est.ups.edu.ec agonzalezl1@est.ups.edu.ec clegarda@est.ups.edu.ec
msanchot@est.ups.edu.ec fsigcha@est.ups.edu.ec
Universidad Politcnica Salesiana - Sede Cuenca
Laboratorio de Maquinas Elctricas I
Resumen--- En este informe se presenta la determinacin de
relacin de transformacin del transformador, con la ayuda
del mdulo feedback 61-106.
Palabras Claves Transformador,
relacin de transformacin.

feedback

61-106,

OBJETIVOS
Objetivo General:
Determinar la relacin de transformacin y la polaridad de
los devanados del transformador monofsico FEEDBACK 61106.

elctrica alterna con otro nivel de voltaje mediante la accin


de un campo magntico. Consta de dos o ms bobinas de
alambre enrollados alrededor de un ncleo. Estas bobinas no
estn conectadas en forma directa. La nica conexin es el
flujo magntico que se encuentra dentro del ncleo.
Uno de los devanados del transformador se conecta a una
fuente de energa elctrica alterna y el segundo devanado
suministra energa elctrica a la carga.
El devanado del transformador que se conecta a la fuente de
potencia se le denomina devanado primario o devanado de
entrada y el devanado que se conecta a la carga se le
denomina devanado secundario o devanado de salida. [1]

Objetivos Especficos:
A partir del transformador monofsico 61-106:

Medir las tensiones del primario y secundario en


distintas configuraciones de conexin de sus
devanados.
Calcular la relacin de transformacin () para
configuracin de sus devanados.
Determinar la polaridad en cada una de sus
configuraciones.

Fig. 1: Construccin del Transformador

I. INTRODUCCIN
En el presente informe se realizara la relacin de
transformacin y la polaridad de un transformador monofsico
feedback, para ello se deber a unir los bobinados secundarios
del transformador para obtener una sola salida, es decir 125V
y se alimentara el transformador con una fuente variable de 0216V, los instrumentos que se utilizaran para medir los
voltajes en el primario y secundario son multmetros digitales.
Estas mediciones se realizaran con el objetivo de saber el tipo
de transformador y su relacin, en este caso es un reductor.
II. MARCO TERICO
2. El Transformador
Un transformador es un dispositivo elctrico que cambia la
potencia elctrica alterna con un nivel de voltaje a potencia

Fig. 2: Simbologa del Transformador

Universidad Politcnica Salesiana-Sede Cuenca.

2.1. Transformador FEEDBACK 61-106


La relacin de tensin nos permite conocer el tipo de
Transformador, el cual puede ser:
Elevador, si < 1
Reductor, si > 1
Aislamiento, si = 1
Como se observa el ejemplo de la figura 4:

Fig. 3: Transformador monofsico 61-106


La Transformador TFM ofrece dos mdulos adicionales; el
transformador monofsico 61-106 presentada en la figura 3 y
los transformadores trifsicos 61-107. Cada una est
completamente cerrado por seguridad y protegida
elctricamente. El panel frontal que tienen, proporciona
diagramas que simplifican las conexiones experimentales.
Para poder obtener diferentes tipos de conexin, como las de
sin carga y con carga rendimiento, autotransformadores,
estrella, delta, delta abierta y en zig-zag arrollamientos
relaciones de fase primaria-secundaria y la eficiencia. [2]

Fig. 4: Relacin de vueltas tensin Step Up (Aumenta),


tensin Step- Down (Disminuye)

2.2.1 Relacin de Transformacin


El termino relacin de transformacin hace referencia al
aumento o decremento que sufre la tensin a la salida del
transformador con respecto a su entrada, esta relacin es
directamente proporcional al devanado y numero de espiras
que posea un transformador en su bobina primaria y
secundaria. [3]

=

Donde:
Ep fuerza electromotriz inducida al devanado primario.
Es fuerza electromotriz inducida al devanado secundario.
Np nmero de espiras del devanado primario.
Ns nmero de espiras del devanado secundario.

Fig. 5: Relacin de transformacin de un transformador


monofsico
III. DESARROLLO
3.1 Procedimiento:
A continuacin se muestra la configuracin frontal del
transformador monofsico feedback, necesario para el
desarrollo de la prctica:

La relacin de transformacin () de la tensin entre el


bobinado primario y el bobinado secundario depende de los
nmeros de vueltas que tenga cada uno. Si el nmero de
vueltas del secundario es el doble del primario, en el
secundario habr el doble de tensin. [3]


=
=

Fig. 6: Configuracin frontal del transformador monofsico

Universidad Politcnica Salesiana-Sede Cuenca.

feedback 61-106
Para ello se tom varios valores que varan desde 0 hasta
216 volts, mientras que para el voltaje en el secundario se
hizo un puente entre 0V de la seccin 1 y 62.5V de la
seccin 2, obteniendo la siguiente tabla de valores.
VOLTAJE PRIMARIO

UNION ENTRE
BOBNAS
(secundario)

Conexin de
la fuente

Voltaje
aplicado
(V1)

Seccin 1

Seccin 2

216V, 0V

10

0V

62.5 V

216V, 0V

20

216V, 0V

30

216V, 0V

40

216V, 0V

50

216V, 0V

60

216V, 0V

70

216V, 0V

80

216V, 0V

90

216V, 0V

100

216V, 0V

110

216V, 0V

120

216V, 0V

130

216V, 0V

140

216V, 0V

160

216V, 0V

180

216V, 0V

200

216V, 0V

216

216V, 0V

200

216V, 0V

180

216V, 0V

160

216V, 0V

140

216V, 0V

120

216V, 0V

100

216V, 0V

80

216V, 0V

60

216V, 0V

40

216V, 0V

20

VOLTAJE
SECUNDARIO
Conexin del
voltmetro (V2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)
0V (Sec. 1), 62.5
(Sec. 1)
0V (Sec. 2), 62.5
(Sec. 2)
0V (Sec. 2), 62.5
(Sec. 1)

V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V

VOLTAJE PRIMARIO
Conexin de la
fuente

Voltaje
aplicado
(V1)

216V, 0V

10

216V, 0V

20

216V, 0V

30

216V, 0V

40

216V, 0V

50

216V, 0V

60

216V, 0V

70

216V, 0V

80

216V, 0V

90

216V, 0V

100

216V, 0V

110

216V, 0V

120

216V, 0V

130

216V, 0V

140

216V, 0V

160

216V, 0V

180

216V, 0V

200

216V, 0V

216

216V, 0V

200

216V, 0V

180

216V, 0V

160

216V, 0V

140

216V, 0V

120

216V, 0V

100

216V, 0V

80

216V, 0V

60

216V, 0V

40

216V, 0V

20

VOLTAJE
SECUNDARIO
Conexin del
voltmetro
(V2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)
0V (Sec. 2),
62.5 V (Sec. 1)
0V (Sec. 1),
62.5 V (Sec. 1)
0V (Sec. 2),
62.5 V (Sec. 2)

Relacin de
transformaci
n (V1/V2)

Tipo de
transformador
(elevador,
reductor o de
aislamiento)

1.78

Reductor

1.71

Reductor

1.66

Reductor

1.66

Reductor

1.65

Reductor

1.64

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.63

Reductor

1.62

Reductor

1.62

Reductor

1.62

Reductor

1.63

Reductor

1.63

Reductor

1.62

Reductor

1.64

Reductor

1.63

Reductor

1.63

Reductor

1.62

Reductor

1.62

Reductor

V
V
V
V

Tabla 1. Tabla con las configuraciones de conexin de


las bobinas del transformador 61-106 para la
determinacin de la relacin de transformacin.
Una vez con los valores medidos se calcula posteriormente la
relacin de transformacin quedando de la siguiente manera.

Tabla 2. Tabla de la relacin de transformacin


producto de conexin de las bobinas del transformador
61-106.

IV. RECURSOS (ACCESORIOS Y MATERIAL FUNGIBLE):


Banco de mquinas eltricas FEEDBACK.
Fuente de tensin variable, 0 220 V
Modulo de transformador monofsico, 61-106
Cables de conexin (Bananas)
Multmetro, (Varios).

Universidad Politcnica Salesiana-Sede Cuenca.

V.

CONCLUSIONES Y RECOMENDACIONES

(B Criollo) G1

Como conclusin de este informe realizado se puede decir que


la relacin de tensin de un transformador monofsico, est en
funcin de la relacin de vueltas en sus devanados, siendo en
el caso de reductor si alimentamos al primario con mayor
nmero de espiras, se obtiene una tensin en el secundario con
menor nmero de espiras, y siendo el caso de elevador si
alimentamos el secundario con menor nmero de espiras se
obtiene una nueva tensin en el primario con mayor nmero
de espiras, para realizar estos procedimientos tenemos que
tener en cuenta la polaridad de cada devanado al momento de
verificar las tensiones obtenidas.
Como recomendacin para realizar esta prctica, y no se
presenten daos los equipos debemos hacer las conexiones
con los equipos apagados, una vez que se haya armado el
circuito con su debida verificacin procedemos a encender el
modulo para analizar su funcionamiento, tambin se
recomienda, que si se aplica una modificacin en el circuito
primero apagamos el sistema para poder trabajar, esto es muy
til para proteger estos mdulos ya que son muy sensibles
internamente.

(A Gonzlez) G3

Concluimos que la relacin de transformacin y polaridad es


sumamente importante ya que sabemos en cuanto se va a
reducir o elevar la tensin aplicada al transformador, en esta
prctica lo hemos realizado de 10v a 216 v y viceversa, as
evitamos prdidas materiales o tambin evitamos alterar el
funcionamiento de una carga que se vaya a conectar al
transformador, la polaridad nos permite saber cmo realizar la
conexin entre transformadores y la carga. Se pudo garantizar
un buen funcionamiento de las bobinas as como su
conexin al realizar mediciones con los multmetros.

(C Legarda) G1

En conclusin se logra adjuntar que la relacin de


transformacin depende nicamente de la relacin que existe
entre el nmero de vueltas en el devanado primario y en el de
devanado secundario, ya que partiendo de esto podemos saber
que si un transformador de potencia es reductor, elevador o de
estabilizacin, adems se puede acotar que estos
transformadores al ser reales estn expuestos a prdidas ya sea
en el ncleo, tambin por las prdidas de cobre o simplemente
por corrientes parsitas, pero aun as gracias a su diseo de
fabricacin muchos de estos transformadores la pasar de los
aos se ha logrado que las prdidas sean mnimas logrando
aproximarse mucho a un transformador ideal.

(P Sancho) G3

En esta prctica se logr realizar la relacin de transformacin


del transformador, para ello se tuvo que realizar varias
medidas en el bobinado primario y secundario, mediante una
fuente variable, para obtener un voltaje de 125V se tuvo que

4
unir los dos bobinados secundarios del transformador.
Mediante esta relacin se pudo identificar que es un
transformador reductor y su relacin es aproximadamente 1.63
Como recomendacin cuando se finaliza la conexin en el
mdulo, antes de encender el mismo se debe verificar dicho
esquema y su respectiva conexin para evitar sobrecargas o
daos en los aparatos utilizados o mdulos. Para realizar
cualquier tipo de modificacin del circuito, se debe hacer con
el sistema apagado para evitar daos fsicos.

(F Sigcha) G1

Finalizando la prctica hemos determinado la relacin de


transformacin con las mediciones obtenidas en el laboratorio
las cuales estn especificadas en las tablas, en donde a es la
relacin de transformacin, si a es mayor a 1 tenemos un
transformador elevador, si a es menor a 1 se tiene un
transformador reductor y finalmente si a es igual a 1 va ser un
transformador aislante. Adems se determin la polaridad de
un transformador, en nuestro caso era fcil de determinar
porque ya estaba sealizado en el banco de trabajo el voltaje
igual a cero y entonces se pudo concluir el sentido relativo
instantneo del flujo de corriente, pero en los transformadores
que no se tiene esa facilidad se lo realiza con un multmetro
probando en los bornes del primario y secundario cuando el
voltaje es igual a cero ese es el sentido relativo instantneo del
flujo de corriente.

VI. REFERENCIAS
[1]

S. J. Chapman, "Motores sncronos", en Mquinas elctricas, 5 Ed.,


Mxico: Mc. GrawHill, 2005, Cap. 2, pp.48-117
[2]
http://www.feedbackinstruments.com/products/education/electrical_power_machines/single_t
hree_phase_transformers
[3] http://www.n9xh.org/license/pcara_general_upgrade_lesson_08.pdf