6 Circuit Diagram (with AGR-11B OCR)

Main circuit

CT for
neutral line

Continuously-rated
shunt trip

3 Motor charging/

Operation

Operation circuit

i{j
`

1
ON switch
PB

05

02

12

i{j
`

10

Spring
charge
OFF
S1

S3

CT1

CT3

Position switches

Auxiliary switches

UVT power supply


Common 5
PB
i[j
i{j
` ` ` `

PB

03

Undervoltage trip

09 08 18 28

24 30

Basic
4C

151

141

131

121

111

211

Optional
3C

311

411

511

611

Optional
3C

711

811

911

011

UVT control circuit

Over-current release
(type AGR-11B OCR) (40ms)
M

Ry

LRC

SHT 2

UVT

S2
MHT

CT2

19 29
K

15

CT for
neutral line
L

22

7
3

20

Position switches
`
i|j

Symbols for accessories

2C2 ontrol power supply AC100 - 240V, DC100 - 250V, DC24V, DC48V
2Operation switch, common
3ON switch
5Operation indication terminal, common
5OCR trip indication or single-contact trip indication (40ms signal)
7Trip indication (not ready indication)
7Spring charge indicator
UVT power supply
0C0 ontinuously-rated shunt trip
Term. AC 100V AC 200V
No.
unit
unit
9Separate CT for neutral line ( k )
8-9 100V 200V
9Separate CT for neutral line (R)
8-9 110V 220V
8,8,8UVT power supply
8-9 120V 240V
9UVT power supply common
Term.
No.

8-9

DC 24V
unit
24V

CT1 - CT3 : Power CTs


S1 - S3
: Current sensors
M
: Charging motor
LRC
: Latch release coil
MHT
: Magnetic Hold Trigger
Isolating terminal connector
(for draw-out type)
Manual connector
User wiring
X
Relay or indicator lamp

AC 400V
unit
380V
415V
440V

DC 48V DC 100V
unit
unit
48V
100V

154 152 144 142 134 132 124 122 114 112 214 212 314 312 414 412 514 512 614 612 714 712 814 812 914 912 014 012

Designation of terminals for auxiliary and position switches


`
i|j

Check OCR voltage before connecting.

60

27

Terminal description

Do not exceed specified voltages

17

1: Do not connect bcontact of auxiliary switch to ON


switch in series, otherwise, pumping may occur.
2: See P. 23 for the circuit diagram of the continuouslyrated shunt trip device with capacitor trip device.
3: For motor split circuit, terminals 2, 2 and 3, 7 are
used for charging and closing operation respectively.
(Please specify when ordering)
4: Refer to page 24 (short pulse only)
5: Only one of terminals 8, 8, 8 must be used as
this is a single phase UVT.
Note: In case of a UVT and a Shunt fitted together or
Double opening or closing coil, use an aux. switch
to prevent burnout. Contact TERASAKI for wiring.

* * *

1: Common
2: b-contact
4: a-contact
1: Auxiliary switch
2: Position switch (for CONNECTED)
3: Position switch (for TEST)
4: Position switch (for ISOLATED)
5: Position switch (for INSERT)

Top
151 141 131 121
Middle 154 144 134 124
Bottom 152 142 132 122

Operation/control circuits
01 02 03 04 05 06 07 08 09 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30

Top
131 121
Middle 134 124
Bottom 132 122

numbers
( 1A,B,0:C:Switch
Auxiliary switches for microload
CONNECTED position : 121124 ON
121122 OFF
TEST position
: 131134 ON
131132 OFF
ISOLATED position
: 141144 ON
141142 OFF
INSERT position
: 151154 ON
151152 OFF
For operation sequence of
position switches, see page 19.

Auxiliary switches
(4c + optional 6c arrangement)
111 211 311 411 511 611 711 811 911 011
114 214 314 414 514 614 714 814 914 014
112 212 312 412 512 612 712 812 912 012
(4c arrangement)
111 211 311 411
114 214 314 414
112 212 312 412

61