Você está na página 1de 15

Technical manual

Emaris butterfly valves - DN 50 up to 300 mm

Summary

Applications and main


characteristics

Sale leaflet
Spare parts list
Overall dimensions
Top connections of the actuators
Actuators
Connecting flanges
Normalisation
Pressure/Temperature
Torque values
Flow rate (Kv)
Diagramme de pertes de charge (p)
Head loss chart
Tag/Traceability
Bolts and nuts
Installation

p.2
p.3
p.4
p.5
p.6
p.7
p.8
p.9
p.9
p.10
p.11
p.12
p.12
p.13-14
p.15

Performances and reliability in industrial applications with strict conditions of use.

Applications :

Main characteristics :

Any application requiring the use of butterfly


valve with double off set disc and fluid controls
up to 50 bar pressure and -50C till +220C
temperatures.

Application fields :

Steam, district heating, geothermal, industrial processes and refrigeration, pumping, offshore, ship buildings, sugar processing industry,
petrochemical, nuclear, paper industry, etc...

Numerous applications.
Vertical and horizontal mounting of the shaft.
Full range of mounting thanks to centring lug with
multiple connections.
Availability of connections thanks to standardised
fittings.
Available in tapped lug version.
Double off set disc design, reliability of the closing
system and low torque.
Easy access to the packing gland without removing
the actuator.
Direct connection of the actuators on an integrated
arcade.
Tightness seal in PTFE 50% stainless steel loaded.
Reliable technology : no need of spring or
tightness bearing .
The standard version is conformed to the ATEX directive 94/9/CE

An instruction notice specifying the installation characteristics and the commission of the Emaris is added to every product; It is
available on our web site www.socla.com or on request by our sales department.
ukemaris - Updated 07/02/2013

Technical manual

Emaris : High performance butterfly valve

Sale leaflet

By
concentrating
the
technologies
and
ting technical solutions of the highest levels, Socla fulfils its ambition :
competitiveness of a standard range,
reliability,
comprehensive range thanks to a multiplicity of solutions.

Identification and traceability ensured


by riveted metal tag : see page 12.

by

integra-

Body with long neck and integrated arcade,


designed to allow insulation.
Easy access to the packing gland without
removing the actuator.
Excellent dynamic tightness due to easy adjustment of the packing gland.
Direct mounting of the actuators on an integrated arcade with large normalised surface.
Identification and traceability ensured by
riveted metal tag.
Safety anti-ejection circlip keeps shaft in
place

Body : Full range of mounting thanks to centring lug with multiple connections
Fixation of the the guide plate outside of the seal
bearing which guarantees an optimal tightness
on the flange.
Disc : long life durability due to double off set
disc operating principle minimizing seat wear.
Low torque values
Tightness zone extended out of the shaft way.

Excellent guiding and centring of the shaft due


to anti-friction bearings - stainless steel + PTFE.
Single-direction butterfly valve .
Easy-directional maintenance due to a simple
design to avoid any mistake by mounting
the seal.
Assembly of the guide plate by screws ensuring
an easy access to the seal.

The external tightness allows a security at the


lower shaft way thanks to the o-ring.

ukemaris - Updated 07/02/2013

Technical manual

Emaris

Spare parts list


1
2
3
4
5
6
7
8
9
10

11

12
13
14

15

Nb.

DESCRIPTION

Qty

1
2

Nuts
Stop washer

2
4

Plate

4
5
6

1
2
4

Ring
Pin
Ring
Anti-extrusion
bush
Rivet

16

17

18

19

20

21

22

23

MATERIALS ACCORDING TO STANDARDS


JIS

Type of materials
Stainless steel
Stainless steel
Stainless steel
Steel
Stainless steel
Stainless steel marked
Graphite

EN
A2 - 70
A2 - 70
GX5CrNiMo 19-11-2 (1,4408)
X3CrNiMo 17-13-3 (1,4436)
X5CrNiMo17-12-2 (1,4401)
-

ASTM
304
304
316
WCC
316
316
-

SUS 304
SUS 304
SUS 316
SUS 316
SUS 316
-

Stainless steel

X3CrNiMo 17-13-3 (1,4436)

316

SUS 316

Aluminium / Stainless steel

Identification plate

Aluminium

EN AW - AL99,5 (EN AW - 1050A)

10

Body

11
12

Guide bushes
O-ring

2
1

GX5CrNiMo 19-11-2 (1,4408)


-

316
WCC
-

SUS 316
-

13

Bottom

14
15
16
17
18
19
20
21

Anti-static braid
Screw
Stop washer
Pin
Shaft
Disc
Seal
Seal

1
2
1

Stainless steel
Steel
Stainless steel + PTFE
Fluored elastomer
Stainless steel
Steel
Tinned copper
Stainless steel marked
Stainless steel
Stainless steel
Stainless steel
Stainless steel
PTFE loaded 50%stainless steel
Graphite

GX5CrNiMo 19-11-2 (1,4408)


A2-70
A2-70
A2-70
X5CrNiCuNb 16-14 (1,4542)
GX5CrNiMo 19-11-2 (1,4408)
-

316
WCC
304
304
304
630
316
-

SUS 316
SUS 304
SUS 304
SUS 304
SUS 630
SUS 316
-

22

Guide plate

23

Screw

Stainless steel
Steel
Stainless steel marked

GX5CrNiMo 19-11-2 (1,4408)


A2 - 70

316
WCC
304

SUS 316
SUS 304

1
1
1
1

ukemaris - Updated 07/02/2013

Technical manual

Emaris

Overall dimensions
T

H4

H3

H1

H2

D1

D2

N Holes R on S

L1

L2
Flat P

Centring lugs
Diameter

Face
to
face

DN NPS

50

2"

Overall dimensions
L1

H1

H2

H4

Square drive
outlet

Iso top according to EN ISO 5211


N

Travel of the
Weight
disc

Kg

H3 Flat P D1

D2

43

143 165 123

12

8,5

70

90

50

76

F07

11

16

11

35

5,9

65 2 1/2 47

146 175 138

12

8,5

70

90

50

76

F07

11

16

11

48

13

6,8

80

47

160 196 149

12

8,5

70

90

50

76

F07

14

19

14

56

16

100

53

160 213 162

13

8,5

70

90

50

76

F07

14

19

14

80

25

9,5

125

57

185 243 180

18

10,5 102 125

79

85

F10

17

24

20

113

40

13,5

150

57

217 272 197

15

10,5 102 125

79

85

F10

17

24

20

140

53

16,5

200

61

287 311 233

14

10,5 102 150

81

85

F10

17

29

20

188

77

25,7

250 10

69

333 345 265

18

12,5 125 150

81

104 F12

22

29

26

237

98

38,5

300 12"

78

293 360 295 13,5

140 175 106 110 F14

22

29

26

275 112 58,1

17

Tapped lugs
Diameter

Face
to
face

DN NPS

L2

H2

H4

H3 Flat P D1

50

43

146 165 123

12

8,5

70

90

50

76

F07

11

16

11

35

47

178 175 138

12

8,5

70

90

50

76

F07

11

19

11

48

13

9,4

65

2
2

1/2

Overall dimensions
H1

Square drive
outlet

Iso top according to EN ISO 5211

Travel of the
Weight
disc

Kg

D2

80

47

192 196 149

12

8,5

70

90

50

76

F07

14

19

14

56

16

10,3

100

53

241 213 162

13

8,5

70

90

50

76

F07

14

19

14

80

25

16,7

125

57

261 243 180

18

10,5 102 125

79

85

F10

17

25

20

113

40

20,7

150

57

311 272 197

15

10,5 102 125

79

85

F10

17

25

20

140

53

26,5

200

61

375 311 233

14

10,5 102 150

81

85

F10

17

29

20

188

77

40

250 10

69

413 345 265

18

12,5 125 150

81

104 F12

22

29

26

237

98

61,5

300 12"

78

480 360 295 13,5

140 175 106 110 F14

22

29

26

275 112 90,3

ukemaris - Updated 07/02/2013

17

Emaris

H1

H2

Connecting kit for


actuation

H3

Technical manual

N Trous R sur S

We recommend direct mounting of the actuator, otherwise see table below.

Iso top of the actuation


Iso top of
the valve

F04

DN

NPS

50

65

21/2

80

F07/o14

256

100

F07/o14

273

125

150

200

250

10

F12/o22

300

12

F14/o22

H1
225

F07/o11

235

F05

H2
60
60

H1
225
235
256
273

F07

H2

H1
225

60

235
256

60

273

323
352

F10/o17

H2
60

60

323
352

80

391

Iso to of
DN NPS
the valve

F10

391

80

425

Exceeding length of the shaft H3


Kit o9 o11 o14 o17 o22 o27 o36
F04

50-65 21/2

80

F07/o11

3
F07/o14

100

125

200

250

10

F07
F10
F04
F05
F07
F10
F12
F14
F04

11

15

19

24

11

15

19

24

11

15

19

24

H2

H1

F14

H2

H1

F16

H2

H1

H2

245
255
276

80

276

276

293

293

293

323

323

352

80

391

80

80

333

352

362

391

401

435

90

435

90

435

510

150

510

150

510

333
362

90

401

90

435
150

510

150

F04

5,5

42

F05

6,5

50

F07

8,5

70

F10

10,5

102

F12

12,5

125

F14

17

140

F16

22

165

Reminder of the iso top dimensions EN ISO 5211 (see also the
overall dimensions).

F05
F10/o17

150

F05

H1

F12

F07
F10

33

F12

On request : other special executions


is subject to technical feasibility.

F14

F12/o22

F07
F10
F12
F14

11

15

19

24

33

15

19

24

33

F16
F10
300

12

F14/o22

F12
F14
F16

ukemaris - Updated 07/02/2013

Technical manual

Emaris

Actuations

Find below the different standard assembly combinations.


For any other information, please ask our technical Department.

ASSEMBLY LEVEL 2

1 or 2 mechanical limit switch

Switchbox :

. mechanical

. inductive
For other options, please
consult us.

Inductive limit switch

Positioners (1)

ASSEMBLY LEVEL 1

Manual gearbox in
cast iron

Socla

Stainless steel hand lever

Bernard
Manual gearbox in
stainless steel

HAND LEVER

Auma

GEAR BOX

ukemaris - Updated 07/02/2013

GT

PNEUMATIC
ACTUATOR

ELECTRIC
ACTUATOR

Technical manual

Emaris

Connecting flanges

The Emaris butterfly valve can be mounted with the following connections (other
types on request) :
4 : possible mounting
l : possible mounting with re-machining
: impossible mounting

Centring lugs
EN 1092-1 & EN 1092-2

ASME/ANSI B16.5

DN

NPS

50

65

21/2

PN10 PN16

PN25

PN40 Class 150 Class 300

BS10

JIS B 2238 & JIS


B 2239

Table D Table E 10K

16K

4
4

80

100

125

150

200

250

10

300

12

Tapped lugs
DN

NPS

EN 1092-1 & EN 1092-2


PN10 PN16

50
65

2
2

1/2

PN25

ASME/ANSI B16.5

PN40 Class 150 Class 300

BS10

JIS B 2238 & JIS


B 2239

Table D Table E 10K

16K

4
4

80

100

125

150

200

250

10

300

12

Attention : the Emaris lug type body is not a multi-connection body (connection to many flanges of different sizes). Generally, every
connection relates to a different reference of finished products.

End of line mounting and downstream removing


The end of line mounting and the downstream removing, at ambient temperature, of the Emaris butterfly valve is limited to the pressure mentioned on page 9 according to the PED directive 97/23/CE .
These mountings are only possible on tapped lugs bodies.
Downstream
removing

ukemaris - Updated 07/02/2013

End of line
mounting

Technical manual

Emaris

Normalisation

Design :
According to EN 593 and marking according to EN 19
Iso top connection for actuations :
According to EN ISO 5211
Face to face :
According to 558-1 series 20

ISO 5752 series 20

API 609 table 2 Class 300
Connecting flanges : see on page 7
According to EN 1092-1 and EN1092-2 : PN10-16-25-40


ASME/ANSI B16.5 : ASA 150 and 300
Tests :
According to EN12266-1


Resistance and tightness of the body (directive PED 97/23/CE) : test P11 (1,5
x allowable operating pressure).


Tightness of the seat : test P12 rate A (1,1 x allowable operating pressure).
According to EN12266-2


Anti-static design : test F21
European Directives :
Our butterfly valves are in accordance to the safety requirements of the following directives. :
Directive 97/23/CE : Equipments under pressure PED (Pressure Equipment Directive)
Applies to the design, manufacturing and the assessment of the conformity of pressure equipment, the maximum allowable pressure of
which is 0.5 bar.
Pressure equipment for water supply, distribution, and disposal of water is excluded.
Depending on the type of pressure equipment, maximum allowable temperature (PS), DN, physical nature of the fluid (liquid, gas
or vapour) and the degree of danger of the fluid (group1/2)*, the directive classifies this same equipment into different categories
(article 3.3, I, II, III, IV), required for the assessment of conformity with CE marking.
The equipment defined in article 3.3 of the directive must not bear the CE marking.
(*) Group 1 : hazardous fluids (directive 67/548/EEC) / explosive / highly flammable /easily flammable / flammable / very toxic / toxic /
combustion agents.
Group 2 : all other fluids
Important notice : the indicated pressure for the different categories of fluids (L1/L2/G1/G2) is under no condition a guarantee of use.
Therefore, it is essential to validate the use of products under given operating conditions. Socla is not responsible for
alteration of the products to working conditions not previously specified by the customer.
In order to facilitate your choice regarding these new regulatory requirements, Socla has put the necessary information
concerning products with CE marking, specification sheets and product identification plates at your disposal in the price list (+ see additional
explanations on the detachable slip).
In addition, the operating instructions are available on our web site www.socla.com or by simple request from our sales department.

Directive 94/9/CE : ATEX (EXplosive ATmospheres)

This directive is only applicable for the following atmospheric conditions : -20C < T < +60C ; 0,8 bar P 1,2 bar.
In this risk analysis, the fluid which passes through the valve is not taken into account. It is under the responsibility of the user to take into
consideration the risks generated by the fluid like : heating of the surface of the valve, internal chocks generated by granulates, wave of
chocks due to the installation (water hammering), or the risks due to foreign bodies which are inside the installation.
Classification of the bare shaft valve :
The marking of the bare shaft valve is :
II 2 DG.
Classification of the set valve + actuation :
Valve with a hand lever :
The use of hand levers produced by Socla within an ATEX area do not represent additional risks. The valve with a hand lever is in
conformity to the marking :
II 2 DG.
Valve with other actuations :
The classification of the valve + actuation supplied by Socla is similar to the lowest classification of the components which composed
the assembly.
No additional marking will be used to indicate the classification of the assembly.
If a single element of the combination does not carry the ATEX mark, then the entire valve/control combination does not conform
to the ATX directive.
The classification of the equipment allows its use in a determinate area; an use in another area is under the responsibility of the user.

Machinery Directive 2006/42/CE : Machinery Directive

In its Appendix I it sets a certain number of Essential Health and Safety Requirements which must be met. It applies to motorised butterfly
valves, (with electric, pneumatic or hydraulic actuators). According to this Directive, these sets are Partly Completed Machineries designed
for being integrated into a machine.
Partly Completed Machinery means an assembly which is almost machinery but which cannot in itself perform a specific application. A drive
system is partly completed machinery. Partly completed machinery is only intended to be incorporated into or assembled with other machinery or other partly completed machinery or equipment, thereby forming machinery to which this Directive applies.
An instruction notice specifying the installation characteristics and the commission of the Emaris is added to every product; It is
available on our web site www.socla.com or on request by our sales department.
8

ukemaris - Updated 07/02/2013

Technical manual

Emaris

Pressure

DIRECTIVE 97/23/CE Equipments under pressure.


Products manufactured in conformity with the requirements of the directive, according to pressure, DN
and fluid (see on the precedent page ).

DN mm Cat.

LINERS

50 to 100
50 bar

125
150
PTFE reinforced

200
250

25 bar

300

MOUNTING

PFA

II

Flanges

End of line

50
36
50
36
50
36
25
18
25
18
25
18

II

Flanges

End of line

II

Flanges

I
II

End of line
Flanges

End of line

II

Flanges

End of line

II

Flanges

End of line

NOTE : Butterfly valves of category II used as end of line, please consult us.

PS

L1 L2 G1
50
36
50
36
50
36
25
18
25
18
25
18

50
36
50
36
50
36
25
18
25
18
25
18

G2

50
36
28
23
17,5
14
11,5

50
36
40
36
33
33
25
18
20
18
16,5
16,5

Differential pressure : 10 bar maxi

PS : Maximum allowable pressure (in bar) according to Directive 97/23/CE


PFA : Allowable operating pressure (in bar) for supply, distribution and disposal of water.

Pressure/temperature
diagram

Accidental working
condition

DN 50 - 150

10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250

-50
-40
-30
-20
-10

Pressure -bar

DN 200 -300

Temperature - C

Torque values
50

Torques for
water (Nm)
F07/11

65
80
100

F07/11
F07/14
F07/14

37
46
86

44
50
96

46
60
101

50
61
114

65
77
146

77
86
165

125

F10/17

145

173

187

209

269

297

150

F10/17

161

176

219

237

359

424

200

F10/17

360

510

525

550

250

F12/22

550

700

770

800

300

F14/22

DN

PS10

PS16

PS20

PS25

PS40

32

35

40

45

50

PS50

On request

NOTE : One actuation minimum per month.


ukemaris - Updated 07/02/2013

Technical manual

Emaris

Flow rate (Kv)

The butterfly valve is not the best product for regulating


Nevertheless, the Emaris butterfly valve can be used to regulate by an opening stage between 20 and 90.

A regulation in the opening stage lower than 20 is not advisable because of over speed, cavitation effect, which could
damage prematurely the valve.

OPENING STAGE
DN 10 20

30

50
65
80
100
125
150
200
250
300

Consult us
19 36 54 69
31 59 82 103
52 98 147 200
75 133 209 300
135 246 389 541
264 482 761 1058
465 848 1338 1862
Consult us

40 50 60

70
79
114
243
398
689
1348
2370

80 90
83
118
265
465
793
1552
2729

3
84 Kv = volume of water in m /h through a valve at a preset opening stage and under a head loss of 1 bar.
120
270
520
845
1652
2905

GALLON/MIN

M3/H

The maximum flow velocity of the fluid through the valve must not exceed :
- 3 m/s for liquid fluids. Between 3 and 5m/s, the use of the Emaris butterfly valve is possible, but the phenomena of
cavitation, noise, vibration and water hammering increase.
- 20m/s for gas. Between 20 and 25m/s, the use of the Emaris butterfly valve is possible, but the phenomena of
cavitation, noise, vibration and water hammering increase.
- 2 m/s for DN 900 to 1200
- for gas and and pulverulent or paste fluids : please consult us.

15000

4000

10000

3000
2500

8000
6000
5000
4000
3000
2500

1000

300
250

80

100

65

80
60
50
40

100

30
25

40
30
25

20
15
10
8

20

6
5

15

10

3
2.5

8
6
5
4

100

150

150

60
50

125

200

200

80

150

800

400

300
250

"KV"

1000

1500

400

200

1500

600
500

600
500

250

2000

2000

800

DN

2
1.5
1

10

20

30

DN 50 and 300 : please consult us


10

ukemaris - Updated 07/02/2013

40

50

60

OPENING
STAGE
DEGRES D'OUVERTURE

70

80

90

Technical manual

Emaris

Head loss diagram (p)

80
100

200

400

4000

10000

200
2000 3000

5000
6000
7000
8000

150

1000

2500
3000

125

600

2000

100

300 400

1500

80

200

500
600
700
800
900
1000

65

80 100

250
300

DN

40 50 60

150

15 20 25 30

40
50
60

250

15000
6000

20000

10000

25000
30000

FLOW
GALLON/ DEBIT
MIN
M3/H

1
.15 .2

.3

.4 .5 .6 .7 .8 1

3
1.5 2

5 6 7 8

4
3

10

5 6 7 8

15

PSI

10

M/CE
M/WC

DN 50 et 300 : Please consult us

ukemaris - Updated 07/02/2013

11

For other types of flanges, refer to the table


below.
Non appropriate connections will cancel our
guarantee.

A2

The Emaris butterfly valve has been designed


to be mounted on standard flanges. Only
standard flanges type 11, 21 and 34 according to EN 1092 are quite compatible.

A0

Type of flange

A1

Emaris

Technical manual

DN

A0

A1 mini

A2 maxi

B mini

50

42

37

66

100

65

54,5

50

75

115

80

64

60

86

127

100

87,4

80

107

158

125

116,6

115

137

181

150

142,5

140

162

216

200

190

192

215,5

230

250

237

242

265

292

300

278

278

320

370

Tag / traceability
Rep Description

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

12

ukemaris - Updated 07/02/2013

Name of the valve


Reference
Material of the disc
Material of the liner
Pressure PS between flanges L1/L2 (liquid)
Pressure PS between flanges G1/G2 (gas)
Pressure PS end flange L1/L2 (liquid)
Pressure PFA water 20C
Pressure PS end flange G2 (gas)
Number of manufacturing order
Notified Body Number for the Directive PED 97/23/CE
Manufacturing date
Connecting flanges
Limit of use
Approval information zone
Marking relating to the Directive ATEX 94/9/CE

Technical manual

Emaris

Bolts and nuts

Note : Bolts and nuts are not part of our standard supply.

NF EN 1092-1
DN NPS

50

2"

PN10

PN16

PN25

PN40

*Nb rods
or NB
screw

*Nb rods
or NB
screw

*Nb rods
or NB
screw

*Nb rods
or NB
screw

43

17

25

M16

24

M16

24

M16

24

M16

24

65 2"1/2 47
80
3"
47
100 4"
53
125 5"
57
150 6"
57
200 8"
61

18
18
20
20
20
30

28
28
30
30
30
30

8
8
8
8
8
8

M16
M16
M16
M16
M20
M20

24
24
24
24
24
26

8
8
8
8
8
12

M16
M16
M16
M16
M20
M20

24
24
24
24
24
26

8
8
8
8
8
12

M16
M16
M20
M24
M24
M24

24
24
24
24
24
26

8
8
8
8
8
12

M16
M16
M20
M24
M24
M27

24
24
24
24
24
26

250

10"

69

30

30

12

M20

26

12

M24

26

12

M27

26

12

M30

26

300

12"

78

30

45

12

M20

26

12

M24

32

16

M27

32

16

M30

32

NF EN 1092-2
DN NPS

50

PN10

PN16

PN25

PN40

*Nb rods
or NB
screw

*Nb rods
or NB
screw

*Nb rods
or NB
screw

*Nb rods
or NB
screw

43

17

25

M16

24

M16

24

M16

24

M16

24

65 2"1/2 47
80
3"
47
100 4"
53
125 5"
57
150 6"
57
200 8"
61

18
18
20
20
20
30

28
28
30
30
30
30

4
8
8
8
8
8

M16
M16
M16
M16
M20
M20

24
24
24
24
24
26

4
8
8
8
8
12

M16
M16
M16
M16
M20
M20

24
24
24
24
24
26

8
8
8
8
8
12

M16
M16
M20
M24
M24
M24

24
24
24
24
24
26

8
8
8
8
8
12

M16
M16
M20
M24
M24
M27

24
24
24
24
24
30

250

10"

69

30

30

12

M20

26

12

M24

26

12

M27

26

12

M30

35

300

12"

78

30

45

12

M20

26

12

M24

32

16

M27

32

16

M30

40

2"

ASME / ANSI B16.5


DN NPS

Class 150

*Nb rods
V
or NB
UNC
screw

50

Class 300
c

*Nb rods
V
or NB
UNC
screw

43

17

25

5/8"

24

5/8"

24

65 2"1/2 47
80
3"
47
100 4"
53
125 5"
57
150 6"
57
200 8"
61

18
18
20
20
20
30

29
29
30
30
30
30

4
4
8
8
8
8

5/8"
5/8"
5/8"
3/4"
3/4"
7/8"

24
24
24
24
24
26

8
8
8
8
12
12

3/4"
3/4"
3/4"
3/4"
3/4"
1"

24
24
24
24
24
30

250

10"

69

30

30

12

7/8"

26

16 1"1/8 35

300

12"

78

17

25

12

7/8"

26

16 1"1/8 40

2"

* CENTERING LUG TYPE BODY :


Assembly by rods : Number of nuts = 2 x Number of rods (above)
Assembly by bolts : Number of nut = Number of screws (above)
TAPPED LUG TYPE BODY :
Assembly by screws : Number of screws (above)
For any other connecting flanges, please consult the corresponding norms and use the
formula below.
ukemaris - Updated 07/02/2013

13

Technical manual

Emaris

Bolts and nuts

L1
j
c

j
b

For wafer type body ; assembly by rods :

L1 = a + 2(j+b+c)

L1 : minimum length of rods


a : width of the butterfly valve
b : thickness of the flange (customer)
c : thickness of washer + thickness of nut + exceeding length of the rod
j : thickness of the flange seal.

L2
j
c

For wafer type body ; assembly by bolts :

L2 = a + 2b + 2j+ c + f

L2 : minimum length under head of screw


a : width of the butterfly valve
b : thickness of the flange (customer)
c : thickness of washer + thickness of nut + exceeding length of the screw f :
thickness of washer
j : thickness of the flange seal.
f : thickness of the washer

L3

For lug type body ; assembly by screws :

L5
L6

L3 = j + b + e + f et L5 = j + b + e + f
with L4 > L3 - b and L6 > L5 - b

L3 : maximum length under head of screw


L4 : minimum length of the threading of the screw
L5 : maximum length under head of screw
L6 : minimum length of the threading of the screw
a : width of the butterfly valve
b : thickness of the flange (customer)
e : maxi depth of screw
e : maxi depth of screw
f : thickness of washer
j : thickness of flange seal

L4

f
b
j

e'

b
j

L7

L7

For lug type body ; assembly by rods:


V

L7 = d + b + j + e = d + b + j + e

d'

b
j

14

e'

e
a

b
j

ukemaris - Updated 07/02/2013

L7 : total length of the rod


a : width of the butterfly valve
b : thickness of the flange (customer)
d : exceeding length of the rod
d : exceeding length of the rod
e : maxi depth of screw
e : maxi depth of screw
j : thickness of the flange seal

Technical manual

Emaris

Installation

General remarks :
For safety reasons, the installation must take place
under the supervision of authorised people taking
account of local safety instructions and advice.
The handling of butterfly valves and their controls
must be done by staff trained in all technical
aspects of their operation.
Before installation, the pipes must be depressurised and purged (empty of its fluid) in order to
avoid any danger to the operator.
The pipe work must be correctly aligned so that
no extra stress is exerted on the valve casing.
In ATEX zone, check that the pipes are connected
to the earth. Do not use insulating pipes (PVC....)

Installation conditions :
It is recommended that the distances mentioned
below be respected in order to prolong the life
time of the valve.

Check the compatibility of the connection flanges


against the operating pressure : the PN number of
the flanges must be greater or equal to the operating pressure.
The valve is a machined piece of equipment and
must not be used to prise apart the flanges.
An instruction notice specifying the installation
characteristics and the commission of the Emaris is
added to every product. It is available on our web
site www.socla.com or on request by our sales
department.

Mounting the valve close to pipe work junctions


places it in turbulent zones which increase its
wear.

DN

DN

1 DN

2-3 DN

5-6 DN

1 DN

DN

1 DN

2-3 DN

2-3 DN

1 DN

DN
DN

DN

Socla can accept no responsibility for possible errors in catalogue, brochures and other printed material. Socla reserve the right to alter its products without notice. This also applies
to products already agreed. All trademarks in this material are the property of the respective companies.

Socla Sas
365 rue du lieutenant Putier
71530 VIREY LE GRAND
Postal address : CS 10273
71107 CHALON SUR SAONE Cedex

Tel : 33 3 85 97 42 52
Fax : 33 3 85 97 97 42
http://www.socla.com
e-mail:commerfr@socla.com

ukemaris - Updated 07/02/2013

15

Você também pode gostar