Você está na página 1de 21

Document code

Target readers

MMetro 1050 Deployment, Maintenance

Product name

OptiX Metro 1050

Product version

V100R001

Document

V1.0

Engineer
Edited by

Global Technical Service Dept.

version

Topic on OptiX Metro 1050 Product


Features

Prepared by

Bao Lifeng

Date

Reviewed by

Date

Reviewed by

Date

Approved by

Date

January 8, 2004

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Huawei Technologies Co, Ltd


All Rights Reserved

Review Record
Date
2004/01/08

2005-05-10

Revision Version
V1.0

Author
Bao Lifeng

Description
Completed the first draft.

Huawei Confidential. No disclosure without permission.

Page 2 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Contents
Chapter 1 OptiX Metro 1050 System Features..........................................................................
Chapter 2 Metro 1050 Version Features.....................................................................................
Chapter 3 OptiX Metro 1050 Product Structure..........................................................................
3.1 Equipment Structure.......................................................................................................
3.2 System and Interface Relation.....................................................................................
3.3 Bus Structure.............................................................................................................. 12
Chapter 4 Introduction to OptiX Metro 1050 Boards............................................................

14

4.2 PDH Interface Board................................................................................................... 15


4.3 Electrical Interface Commutator................................................................................. 15
4.4 10M/100M Ethernet Electrical Interface Board............................................................ 18
4.5 SDH Interface Board................................................................................................... 18
4.6 System Control & Communication Unit (FSCC)........................................................

19

4.7 Cross Connection/Clock Integrated Unit (XCS)........................................................

19

4.8 Synchronous Clock Interface Unit..............................................................................

19

4.9 Order Wire Processing Board..................................................................................... 19

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 3 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Keyword:
OptiX Metro 1050
Summary:
At present, OptiX Metro 1050 is in the R1 phase, and the protection mode is
the PP/SNCP. OptiX Metro 1050 supports the MSP networking from the R2
version. The matched deployment network management version is OptiX
iManager T2000 V100R006.
Abbreviation list:
None.
Reference list:
None.

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 4 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

OptiX Metro 1050 Product Features


Forward
At present, OptiX Metro 1050 is in the R1 phase, and the protection mode is
the PP/SNCP. OptiX Metro 1050 supports the MSP networking from the R2
version. The matched deployment network management version is OptiX
iManager T2000 V100R006.

Chapter 1

OptiX Metro 1050 System Features

OptiX Metro 1050 is integrated with the SDH and Ethernet technologies, and
can effectively protect services. Currently, the equipment includes type I and
type II. The type I adopts rear leading-out mode, and the type II adopts front
leading-out mode.

Figure 1.1

2005-05-10

OptiX Metro 1050 type I subrack (front view)

Huawei Confidential. No disclosure without permission.

Page 5 of 21

Topic on OptiX Metro 1050 Product Features

Figure 1.2

OptiX Metro 1050 type I subrack (rear view)

Figure 1.3

OptiX Metro 1050 type II subrack structure

Confidentiality Level:
Internal Use Only

Table 3.1 OptiX Metro 1050 interface type and access capacity
Interface type
SDH interface

STM-1 and STM-4 optical interface

Maximum access capacity of single equipment


6-channel STM-1 optical interface, or 2-channel STM-4 optical
interface.

PDH interface

E1/T1 and E3/DS3 electrical signal


interface

Ethernet interface

10M/100M Ethernet electrical signal

96-channel E1/T1 signal access or 18-channel E3/DS3 service


access.
12-channel 10M/100M Ethernet service access.

interface
Auxiliary interface

Network management interface


External clock interface

1-channel Ethernet interface and 1-channel F&f interface.


2-channel external clock signal output, 2-channel external
clock signal input. The clock signal can be 2MHz or 2Mbit/s.

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 6 of 21

Topic on OptiX Metro 1050 Product Features

Environment monitoring interface

Confidentiality Level:
Internal Use Only

4-channel Boolean interface (3 channels for input, and 1


channel for output).

Data communication interface

4-channel data communication interface (multiplexing with the


environment monitoring interface).

Order wire interface

1-channel PHONE interface.

Table 3.2 OptiX Metro 1050 protection function


Power module 1 + 1 protection.

Equipment-level
protection

Cross connection and clock processing unit 1 + 1 protection.


1 group E1/T1 1:N(N5) TPS protection
2 groups E3/DS3 1:N(N2)TPS protection
1 group E1/T1 and 1 group E3/DS3 1:N (N2) TPS mixing protection.
Note: E3/T3 protection group is in slots 4, 5 and 6. E1/T1 protection group is in slots 10, 11, and 12. Slots 6 and
12 are the protection slots for E3/T3 and E1/T1 respectively.
The main control unit data is backed up in the cross connection and clock processing board.

Network-level

Support sub-net connection protection (SNCP/PP)

protection

Support multiplex section protection (LMSP/MSP)

Table 3.3 OptiX Metro 1050 other features


Features

Description

Two equipment structures are available,

OptiX Metro 1050 type I structure is shown in Figure 1 and. Figure 2.

applying for multiple environments. Two

OptiX Metro 1050 type II structure is shown in Figure 3.

equipment is delivered at the same time. It


is subject to the requirements of the
customer.
Low cost and high integration

OptiX Metro 1050 is designed in the box type, featuring small size and low cost.

Flexible mounting mode

1) Wall hung mounting.


2) Cabinet mounting, including:
ETSI 300mm depth cabinet.
ETSI 600mm depth cabinet.
Standard 19-inch cabinet.
Huawei 19-inch open cabinet.
Huawei C series cabinets.

DCC resources flexible configuration


ECC transparent transmission capability

The DCC can be configured in D1-D3 bytes, or D4-D12 bytes.


OptiX Metro 1050 provides 6-channel ECC processing capability to transfer the
network management information. D1-D3 bytes or D4-D12 bytes can be used to
transfer the network management information, to transparently transmit the DCC
bytes (that are not used or used by other manufacturers).

Powerful cross connection capability

2005-05-10

The equipment has 2020 VC-4 cross connection capability.

Huawei Confidential. No disclosure without permission.

Page 7 of 21

Topic on OptiX Metro 1050 Product Features

Features

Confidentiality Level:
Internal Use Only

Description

Providing multi-channel clock source.

The equipment has clock sources ranging from 1 channel to 23 channels, including
1 internal clock source, up to 18 tributaries clock source, 2 line clock sources, and 2
external clock source.

Power and environment parameter

1) he equipment can monitor the power under-/over-voltage states.

monitoring

2) The equipment can provide alarm input/output function. The alarm input function
can realize the remote monitoring of user environment. The alarm output function
can realize the centralized monitoring of each equipment alarm through the
connection with the alarm interface of the first cabinet of each row.

Synchronous Status Message (SSM)

Support SSM management function.

management function

Chapter 2 Metro 1050 Version Features


For Metro 1050, there are three R versions: V100R001, V100R002 and
V100R003. V100R001 has three B versions: V100R001B01, V100R001B02
and V100R003. The version relation is shown below.
Platform: 5.00.04
Network Management: R008
V100R001B01
V100R001B01

V100R001B02
V100R001B02

V100R002
V100R002

Platform: 5.00.04
Platform: 5.00.03
Network Management: R006
Network Management:R004

V100R003
V100R003

Platform: 5.00.06C02
Network Management: R009
V100R001B03
V100R001B03

Platform: 5.00.06C01

Features of each version is described below:


Table 1.1 V100 R version and R versions B version
R Version
R001

B Version
B01

Feature
STM-1/STM-4

Description
Support 2-channel STM-1 optical interface access. Support 2-channel
STM-4 optical interface access. STM-1/4 line and cross connection
clock are integrated in the same board. STM-1 and STM-4 cannot be
accessed at the same time.

E1/T1 access

Support up to 16 6 channels. In the case of TPS protection (1:5),


support up to 16 5 channels.

E3/DS3 access

Support up to 3 6 channels. In the case of TPS protection (two groups


1:2), support up to 3 4 channels.

Network protection PP protection and SNCP protection.


2005-05-10

Huawei Confidential. No disclosure without permission.

Page 8 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Equipment

Power backup (the power is -48/-60 VDC), cross connection clock

protection

backup, main control board data backup, and tributary TPS protection.

DCC transparent

The DCC can be configured with D1-D3 bytes or D4-D12 bytes. The

transmission

network management information can be transmitted in D1-D3 bytes or


D4-D12 bytes.

Other interface

Order wire, external clock interface, Boolean interface, debug serial port,
network management interface.

B02

Ethernet access

(compatible

ET1

with B01)

FE electrical interface service access, layer 2 switching. Support


generation tree protocol, layer 2 multicast, VLAN identification, VLANbased service convergence, port-based flow control, and so on. The
system supports up to 12 channels, supports ML-PPP, and the mapping

granule is VC-12. The maximum bandwidth provided by each FE


port is 32 VC12. The maximum bandwidth provide by two ports is
32 VC12.
Network protection Linear multiplex section protection (1+1, 1:1).
Independent line
board

1-channel/2-channel STM-1 optical interface board, adding STM-1


access capability.

Front leading-out

Front leading-out area is in the No.6 board of Layer 2. The external

equipment form

clock board and interface board can share the same position.

220V power board 220V AC power board, with the basic alarm performance.
B03

TL1 interface

TL1 user interface is based on the management object.

TL1 specification

Adaptation management object and TL1 interface SDH and Ethernet


software specifications.

R002

TP4 NM protocol

TP4 NM NE communication and NE interconnection protocol.

TP4 software

Software loading based on TP4, PFCSocket protocols, and network

loading

management.

OSI over DCC

TP4 network management information is interconnected with the DCC.

EMS

Up to 4 6 channels Ethernet FE electrical access, with VC3/VC12

(Compatible with

granule. Support three encapsulation forms: GFP, HDLC and LAPS.

R001B02)

Support L2 Switch,VLAN;LCAS/CAR,MPLS.
MSP

Two-fiber unidirectional

STM-1/STM-4,1:1 protection. Maximum service capacity is 2STM-4

multiplex section
protection ring
Two-fiber bidirectional

STM-4,1:1 protection. Maximum service capacity is 2STM-4

multiplex section shared


ring
Optical fiber shared virtual path

The optical fibers in the different protection modes are shared. The

protection

multiplex section protection and the SNCP protection are in the same
optical fiber.

Better SDH function (software)

2005-05-10

Support E1/T1 frame format and CRC check.

Huawei Confidential. No disclosure without permission.

Page 9 of 21

Topic on OptiX Metro 1050 Product Features

R003 (Compatible

N64K

Confidentiality Level:
Internal Use Only

Up to 46 channels N64 electrical interface access. Support

with R001 and

X.21/V.24/V.35/RS-449/EIA-530 interface protocol signal and 2-channel

R002)

Framed E1 format.
155M electrical interface

Up to 21 channels 155M electrical interface access. STM-1 electrical


signal can be directly added to and dropped from the Metro1050 NE.

STM-1 single fiber receive/transmit

Up to 22 channels STM-1 single fiber bidirectional optical interface


access. Provide single fiber receive/transmit capability.

Better SDH function (software)

External clock resistance query.


OSI over DCC, realizing the interworking of the network management
information based on the standard protocol stack.
Support external clock interface to transmit the network management
information.
TL1 specifications: Adaptive to management object and SDH and
Ethernet software of TL1 interface.
Database backup scheme optimization.
Support SNMP NM V3 interface, support performance and alarm
processing board and interface board matching detection.
External clock resistance query.

Chapter 3 OptiX Metro 1050 Product Structure


3.1 Equipment Structure
OptiX Metro 1050 is designed in a box, integrated with box, fan board, power
filtering board, board insertion area and air filter. The structure complies with
19-inch 3U standard subrack specifications in IEC297.
Equipment feature parameter:
Dimensions: 436mm (W) x 365mm (D) x 130.6mm (H)
Power: -48V/-60V DC, range: -38.4 to -72V
Power consumption: Less than 90W (fully equipped)

3.2 System and Interface Relation


Figures 3-1, 3-2 and 3-3 show the interfaces relation of OptiX Metro 1050.

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 10 of 21

Topic on OptiX Metro 1050 Product Features

XCS B

Slot
XCS
A 1

Slot 2

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 9

Slot 10

Slot 11

Slot 12

Slot 13

Figure 1.1

Confidentiality Level:
Internal Use Only

Slot 3

OptiX Metro 1050 type I front panel slots allocation

XCS
B 21
Slot
Slot 26

Slot 25

Slot 24

Slot 32

Slot 31

Slot 30

Figure 1.2

OptiX Metro 1050 type I rear panel slots allocation

Slot 24

Slot 25

Slot 26

Slot 30

Slot 31

Slot 21/32
21

Slot 13

Figure 1.3

XCS B

XCSSlot
A 1

Slot 2

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 9

Slot 10

Slot 11

Slot 12

Slot 3

OptiX Metro 1050 type II front panel slots allocation

The front panel of type I equipment can be inserted with PDH electrical
interface processing board, SDH optical interface board, Ethernet interface
board, cross connection and clock board, main control board, power board,
order wire board and fan board. The correspondence between slots and
corresponding boards is shown as follows:

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 11 of 21

Topic on OptiX Metro 1050 Product Features

Table 3.1

Confidentiality Level:
Internal Use Only

Correspondence between slots and corresponding boards in front panel of OptiX Metro 1050 type I
Slot

Corresponding board

Slot 1, 2

PIU

Slot 3

FSCC

Slot 4, 5, 6, 10, 11, 12

PL1S, PL1D, PM1S, PM1D, PF1S, PF1D, PL3, ET1D

Slot 10, 11

SL1, SD1

Slot 7, 8

XCS4, XCS1, XCS

Slot 9

FEOW

Slot 13

FAN

The rear panel of type I equipment provides the board for leading-out cables
and switching board used together with the PDH electrical interface
processing board, cross connection and clock board. The board for leadingout cables and switching board can be inserted with the PDH electrical
interface commutator, PDH electrical interface switching & bridging unit, and
external clock interface board.
Table 3-1 describes the correspondence between slots and boards of type I
equipment. Table 3-2 describes the correspondence between the Slot of the
board for leading-out cables and processing board slots.
Table 3.2 Correspondence between slots and corresponding boards in rear panel of OptiX Metro 1050 type I
Corresponding board

Slot
Slot 21

STIA/STIB

Slot 24, 25, 26, 30, 31, 32

C12, C12S, C34S

Slot 26, 32

TSB3

Table 3.3 Correspondence between the Slot of the board for leading-out cables and processing board slots of OptiX
Metro 1050 type I
Slot of the board for leading-out cables
Slot 24

Corresponding processing board slot


Slot 4

Slot 25

Slot 5

Slot 26

Slot 6

Slot 30

Slot 10

Slot 31

Slot 11

Slot 32

Slot 12

Slot 21

Slot 7. 8

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 12 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Table 3-3 describes the correspondence between slots and boards of type II equipment.
Table 3-4 describes the correspondence between the Slot of the board for leading-out
cabless and processing board slots.
Table 3.4 Correspondence between slots and corresponding boards in OptiX Metro 1050 type II
Slot

Corresponding board

Slot 1.2

PIU

Slot 3

FSCC

Slot 4, 5, 6, 10, 11, 12

PL1S, PL1D, PM1S, PM1D, PF1S, PF1D, PL3, ET1D

Slot 10. 11

SL1, SD1

Slot 7. 8

XCS4, XCS1, XCS

Slot 9

FEOW

Slot 13

FAN

Slot 21

STIC/STID

Slot 24, 25, 26, 30, 31, 32

C12, C12S, C34S

Slot 26, 32

TSB3

Table 3.5 Correspondence between the Slot of the board for leading-out cabless and processing board slots of OptiX
Metro 1050 type II
Slot of the board for leading-out cables

Corresponding processing board slot

Slot 24

Slot 4

Slot 25

Slot 5

Slot 26

Slot 6

Slot 30

Slot 10

Slot 31

Slot 11

Slot 32

Slot 12

Slot 21

Slot 7. 8

Note:
In the Type II equipment, the external clock interface board STIC/STID and PDH electrical
interface bridging board C12/C12S/C34S/TSB3 occupy the same Slot21 (or Slot 32). When
the slot is inserted with the STIC/STID board, the slot No. is 21. When the slot is inserted with
the PDH electrical interface commutator or switching board, the slot No. is 32.
When the type II equipment is configured with the TPS protection of E1/T1 electrical interface
board, Slot 32 can only be inserted with the C12S, and the other external clock should not be
connected.
When E3/DS3 electrical interface board is in the two groups TPS protection, Slot 32 can only
be inserted with the TSB3, and other external clock should not be connected.

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 13 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

When the equipment is configured with the E1/T1 and E3/DS3 mixing protection, Slot 26 can
only be inserted with the TSB3, and Slot 32 can only be inserted with the C12S.

3.3 Bus Structure


OptiX Metro 1050 equipment provides up to 2020VC4(1260 1260 VC-12)
space division cross connection capability. Slot 7 and Slot 8 (17 and 18
logical board position) respectively occupy four buses. Slot 4, Slot 5, Slot 10
and Slot 11 respectively occupy two buses. Slot 6 and Slot 12 uplink have
one bus, and downlink have two buses, to facilitate the XCS broadcast and
complete PP/SNCP protection function. The buses from the service slot to
the active/standby cross connection slot are symmetric. The service bus
allocation is shown below:
Standby cross connection/clock
Active cross connection/clock

slot1
SPIU
slot2
SPIU

slot4

2
2
2
2

4X38M
4X38M
4X38M
4X38M

slot5

2
2
2
2

4X38M
4X38M
4X38M
4X38M

slot3
FSCC
slot6
slot9
slot10

slot8

XCS

2 4X38M
2 4X38M
1 4X38M
1 4X38M
2 4X38M
2 4X38M
2 4X38M
2 4X38M

slot11

2
2
2
2

4X38M
4X38M
4X38M
4X38M

slot12

2
2
1
1

4X38M
4X38M
4X38M
4X38M

slot7
Optical
sub-board

4
4
4
4

4X38M
4X38M
4X38M
4X38M

slot8
Optical
sub-board

4
4
4
4

4X38M
4X38M
4X38M
4X38M

Figure 1.1

slot7

Service bus allocation

OptiX Metro 1050 provides up to 6-channel ECC processing capability. Slot


4/Slot 5, Slot 7/Slot 8, and Slot 10/Slot 11 are respectively allocated with one
ECC route. The overhead pairing relation is: Slot 4 and Slot 5, Slot 7 and
2005-05-10

Huawei Confidential. No disclosure without permission.

Page 14 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Slot 8 (the logical slot corresponding to the line board is Slot 17 and Slot 18),
Slot 10 and Slot 11. When the FSCC is not in the position, the overhead of
the pairing slot can realize the connection. The overhead bus is allocated as
follows:

8M HW
slot4

slot5

8M HW

8M HW
slot10

slot11

slot7

slot8

8M HW

FSCC

8M HW
2M HW

8M HW
2M HW

FEOW slot9

2M HW
2M HW

Figure 1.2

Overhead bus allocation

Chapter 4 Introduction to OptiX Metro 1050


Boards
Table 1.1 Board category
Unit name
PDH interface unit

2005-05-10

Function description
PL1S

8 2048kbit/s electrical interface board

PL1D

16 2048kbit/s electrical interface board

PF1S

8 2048kbit/s electrical interface board (support the frame structure)

PF1D

16 2048kbit/s electrical interface board (support frame structure)

PM1S

8 2048kbit/s or 8 1544kbit/s electrical interface board

Huawei Confidential. No disclosure without permission.

Page 15 of 21

Topic on OptiX Metro 1050 Product Features

Unit name

Function description
PM1D

16 2048kbit/s or 16 1544kbit/s electrical interface board

PL3

3 34368kbit/s or 44736kbit/s electrical interface board

Ethernet interface unit

ET1D

2-port 10/100M Ethernet electrical interface board

SDH interface unit

OSB1

STM-1 optical interface board

OSB4

STM-4 optical interface board

SL1

STM-1 optical interface board

SD1

2STM-1 optical interface board

Cross connection and

XCS

Cross connection and timing board

timing unit

XCS1

Cross connection and timing board integrated with the OSB1

XCS4

Cross connection and timing board integrated with the OSB4

System control unit

FSCC

Main control board

Order wire unit

FEOW

Order wire board

Power supply unit

PIU

Power board

FAN

Fan board

C12

2048kbit/s or 1544kbit/s electrical interface commutator

Fan unit
Electrical interface

Confidentiality Level:
Internal Use Only

commutator
Electrical interface

C12S

switching and bridging


unit

2048kbit/s or 1544kbit/s 75 ohm/120 ohm /100 ohm electrical interface switching & bridging
unit

C34S

34368kbit/s or 44736kbit/s electrical interface switching board

TSB3

34368kbit/s or 44736kbit/s electrical interface switching & bridging unit

Synchronous timing

STIA

Synchronous timing interface unit75 ohm, applicable for OptiX Metro I

interface unit

STIB

Synchronous timing interface unit120 ohm, applicable for OptiX Metro I

STIC

Synchronous timing interface unit75 ohm, applicable for OptiX Metro II

STID

Synchronous timing interface unit120 ohm, applicable for OptiX Metro II

4.2 PDH Interface Board


On the board panel, A in the bar code indicates the 75 ohm board in the
interface, and B in the bar code indicates the 120 ohm board in the
interface.
E1/E3 signal is in the HDB3 code. T1 signal is in B8ZS or AMI code. DS3
signal of the interface is in B3ZS code.
On the board front panel, there is no connector, and the electrical signal
must be accessed in conjunction with the C12/C34S or C34/C34S.
There is an indicator in the PDH interface board:

If the indicator is On (green), the board is configured with the data and

is in the operation status.


2005-05-10

Huawei Confidential. No disclosure without permission.

Page 16 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

If the indicator is Off, the board is not configured with services or is in

the protection status.


When the PL3 board is configured with the TPS, E3/DS3 signal input and
output must be completed in conjunction with the C34S and TSB3 boards.

4.3 Electrical Interface Commutator


The C12 completes E1/T1 electrical signal conversion function together with
PL1D, PL1S, PM1D, PM1S, PF1D, and PF1S. When the TPS protection is
configured, C12S must be used. When the TPS is not configured, C12S can
be used together with the C12.
C34S board is the 3-channel E3/DS3 signal commutator, and completes
E3/DS3 electrical signal conversion together with the PL3. When the
equipment is configured with the TPS protection, the C34S board can be
inserted in Slot 24, 25, 30 and 31 (When Slot 26 and Slot 32 are inserted
with the TSB3, E3/DS3 signal TPS function must be completed together with
the TSB3). When the equipment is not configured with the TPS protection,
C34S board can be used as the signal commutator, and inserted in Slots
24,25,26,30,31,32. Schematic diagrams of C12S, C34S and TSB3 are
shown below:
Switch control module
slot 4 5 610 11

Cable

slot 12

DB78
Connector
Cable

slot 4 5 610 11
slot 12

Figure 1.1

C12S board principle

Take 1-channel E1/T1 signal input and output as an example to introduce


C12S board working principle:
In the normal status, the switch is toggled to the working position of E1/T1
electrical interface board bus. When the switching event occurs, the switch is
toggled to the protection position of E1/T1 electrical interface board bus.

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 17 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Switch control module

slot 451011

Cable

Protection bus

BNC
Conne
ctor

slot 4561011

Cable

Protection bus

Figure 1.2

slot 2632

slot 2632

C34S board principle

Take 1-channel E3/DS3 signal input and output as an example to introduce


C34S board working principle:
Receiving direction:
Normally, the E3/DS3 signal from the cable is input to the PL3 board of the
working slots (Slot 4, 5, 10 and 11) after the switch control module.
When the equipment detects the TPS switching event, the E3/DS3 signal
from the cable is switched to the protection bus in the switch control module,
and is sent to the TSB3 board of Slots 26 and 32.
Transmitting direction
Normally, the E3/DS3 signal output from the PL3 board of the working slots
(Slot 4, 5, 10, and 11) is output to the cable through the switch control
module.
When the equipment detects the TPS switching event, the switching occurs
in the switch of the switch control module. Now the power control module
receives the E3/DS3 signal sent from the TSB3 (from Slot 26, 32) from the
protection bus, and the signal is output to the cable.
Switch control module

slot 2531

Protection bus

Protection bus

slot 612

slot 2430

Figure 1.3

2005-05-10

TSB3 board principle

Huawei Confidential. No disclosure without permission.

Page 18 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Take 1-channel E3/DS3 signal as an example to introduce the principle of


the TSB3.
Receiving direction:
If the PL3 board in the Slot 5 or 11 is faulty, the E3/DS3 signal input from the
C34S board (in the Slot 25 or 31) is input to the PL3 board in Slot 6 or 12
through the switch control module.
If the PL3 board in the Slot 4 or 10 is faulty, the switching occurs to the
switch of the switch control module. The E3/DS3 signal input from the C34
board (in the Slot 24 or 30) is input to the PL3 board in Slot 6 or 12 through
the switch control module.
Transmitting direction:
If the PL3 board in the Slot 5 or 11 is faulty, the E3/DS3 signal output from
the protection slots (Slot 6 or 12) is sent to the C34S board in Slot 25 or 31
through the switch control module.
If the PL3 board in the Slot 4 or 10 is faulty, the switching occurs to the
switch of the switch control module. The E3/DS3 signal output from the
protection slots (Slot 6 or 12) is output to the C34S board in Slot 24 or 30
through the switch control module.

4.4 10M/100M Ethernet Electrical Interface Board


ET1D provides the access, transparent transmission and switching of 2channel 10M/100M Ethernet signal service. For the note of working principle
and deployment in detail, see the guide to the board deployment.

4.5 SDH Interface Board


The OSB1 is 155M optical interface board, and integrated in the XCS board
(in this case, the board name is XCS1). The OSB4 is 6222M optical interface
board, and integrated in the XCS board (in this case, the board name is
XCS4). The SL1 is 155M optical interface board, and the SD1 is 155M dual
optical interface board. SL1/SD1 can be inserted in Slot 10 and 11. Table 10
describes the standard and parameters of the corresponding optical
interface.

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 19 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

Table 1.1 OptiX Metro 1050 optical interface parameter


Parameter

Description
SL1

SD1

OSB1

Connector

SC

Fiber

1310nm, single mode optical fiber

Optical module code

Ie-1

S-1.1

L-1.1

L-1.2

Transmission distance

0.5km

15km

50km

80km

-19 to -14 dBm

-8 to -15dBm

0 to -5dBm

0 to -5dBm

-23 dBm

-28 dBm

-34 dBm

-34 dBm

-14 dBm

-8 dBm

-10 dBm

-10 dBm

Average transmitting optical


power
Receiving sensitivity
Overload point
Parameter

Description
OSB4

Connector

SC

Optical fiber

1310nm,single mode optical fiber

Optical module code

Ie-4

S-4.1

L-4.1

L-4.2

Transmission distance

25km

50km

80km

Average transmitting optical

-8 to -15dBm

-8 to -15dBm

-23 dBm

-28 dBm

+2 to -3dBm

+2 to -3dBm

power
Receiving sensitivity

-28 dBm

-28 dBm

4.6 System Control & Communication Unit (FSCC)


The FSCC provides up to 6-channel DCC processing capability, and is
located in Slot 3. Metro 1050 NE ID can be set through command line.
During the deployment and commissioning, the DIP switch of the FSCC
should not be set, and the factory default setting is recommended. The NE
ID and IP can be set through the command lines.

4.7 Cross Connection/Clock Integrated Unit (XCS)


The XCS1 is integrated with the cross connection and clock unit of the
OSB1. The XCS4 is integrated with the cross connection and clock unit of
the OSB4. The XCS/XCS1/XCS4 is inserted in Slot 7 and Slot 8 (They are
shown as Slot 17 and Slot 18 in the network management system). The XCS
provides board temperature detection, main control service data backup,
and board 1+1 hot backup to complete the service scheduling function. The
XCS only supports space division cross connection, and does not support
time division cross connection.

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 20 of 21

Topic on OptiX Metro 1050 Product Features

Confidentiality Level:
Internal Use Only

4.8 Synchronous Clock Interface Unit


STIA/STIB applies for type I equipment (A refers to 75 ohm interface and B
refers to 120 ohm interface). STIC/STID applies for type II equipment (C
refers to 75 ohm interface and D refers to 120 ohm interface). For A/C
interface, see the board silkscreen. B/D is DB9 interface. Definitions of pins
are as follows:
Table 1.1 Definition of DB9 pin in STIB/STID board
Pin

Signal

Description

GND

Protection ground

EXT1R+

1st channel external clock positive input

EXT1T+

1st channel external clock positive output

EXT1R-

1st channel external clock negative input

EXT1T-

1st channel external clock negative output

EXT2T+

2nd channel external clock positive input

EXT2R+

2nd channel external clock positive output

EXT2T-

2nd channel external clock negative input

EXT2R-

2nd channel external clock negative output

4.9 Order Wire Processing Board


The order wire processing board is in Slot 9, and completes the RS-232 data
broadcast interface of 1-channel order wire phone (supporting addressing
call and meeting call) and 4-channel transparent transmission. The
maximum rate of data broadcast interface is 19.2kbit/s (it can also be used
as 3-channel Boolean to input -S1/S2/S3 and 1-channel Boolean to output
S4). The order wire interface is RJ11. S1-S4 adopt RJ45 interface. The order
wire works in DTMF mode, and uses E1/E2 byte. S1/S2/S3/S4 interface
respectively uses X1/X2/X3/F2 bytes.
Note
Metro 1050 system does not provide the order wire outgoing subnet
connection function.

2005-05-10

Huawei Confidential. No disclosure without permission.

Page 21 of 21