INTRODUCTION
Adding a Femto cell layer can be a solution to improve coverage quality
and capacity
Two carriers allocation strategies are possible
o Femto network deployed on 3G macro carrier
o Femto network deployed on a dedicated carrier

5
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Small cell solution architecture


The high level system architecture for small cell as defined by 3gpp

6
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

AGENDA

Item 1 | Introduction
Item 2 | Product Overview
Item 3 | Femto Indoor RF Guidelines
Item 4 | Femto Outdoor RF Guidelines

7
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Enterprise V2.2 2100 Mhz Small Cell with


Integrated Antennas
The Alcatel-Lucent 9362 enterprise cell v2.2 2100Mhz is designed to be
located indoors for filling holes in coverage within building to improve network
reach and increase capacity
Radio Characteristic
 Operation Band : 2100 Mhz (UMTS)
 Listening band

2100 Mhz (UMTS)

900/1800 GSM

 Capacity

Pay as you grow capacity 16 ,24, 32 users

 Maximum bearer

21 Mb/s L1 HSDPA+ bearer

5.7 Mb/s L1 HSUPA bearer

 Maximum Transmission Power


100 mW output power (option increase to 250 mW with licensing)
 -2 dBi internal antenna
 Can use with power supply by PoE+ injector
8
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Enterprise V2.2 2100 Mhz Small Cell with


Integrated Antennas Antenna Pattern

9
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Home Cell ASKEY V3


The Alcatel-Lucent 9361 home cell askey v3 20 mW is a
low power, high capacity wireless device designed to be
located indoors for filling holes in coverage
Radio Characteristic

 Operation Band : 2100 Mhz (UMTS)


 Listening band
2100 Mhz (UMTS)
900/1800 GSM

 Capacity
8 devices with each connection supporting a simultaneous voice
call and data session

 Maximum bearer
21 Mb/s L1 HSDPA+ bearer
5.7 Mb/s L1 HSUPA bearer

 Maximum Transmission Power : 20 mW output power


 -2 dBi internal antenna
10
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Home Cell ASKEY V3- Antenna Pattern

11
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Metro Cell Outdoor V2 2100Mhz


The Alcatel-Lucent 9364 metro cell is more than extending
coverage and capacity. It also enables the creation of new
and innovative applications
Radio Characteristic
 Operation Band : 2100 Mhz (UMTS)

Capacity
Pay as you grow capacity 16 ,24, 32 users

 Maximum Transmission Power : 250 mW output power


 Maximum bearer
21 Mb/s L1 HSDPA+ bearer
5.7 Mb/s L1 HSUPA bearer

 Power supply by PoE+ injector


 Support 2 external antenna with N-type Male
 Compact size 241x241x53 mm with 2kg weight
12
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Light Radio Metro Cell Outdoor (MCO)


The Alcatel-Lucent 9764 LR MCO is the entire solution with all
the parts assembled. It share a common look & fell as well as
a simple installation
Radio Characteristic
 Operation Band : 2100 Mhz (UMTS)

Capacity
Support up to 32 users

 Maximum Transmission Power : 1 W output power at


internal antenna connector
 Maximum bearer
21 Mb/s L1 HSDPA+ bearer
5.7 Mb/s L1 HSUPA bearer

 Flexible media connector :either Optical GE(1000Base-X) or


Electrical GE(1000Base-T) using (SFP)
 Integrated two directional cross polarized antennas with a
8.5 dBi gain
 Compact size 350x 138x 124 mm with 4.5kg weight
13
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

LR MCO 1W - Antenna Pattern

14
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

AGENDA

Item 1 | Introduction
Item 2 | Product Overview
Item 3 | Femto Indoor RF Guidelines
Item 4 | Femto Outdoor RF Guideline

15
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Small Cell RF deployment Process


3 Scenarios are considered:
Coverage only :
Coverage is not ensured through the underlay Macro (indoor/outdoor)
Small Cells are used to fill coverage holes

Capacity only :
Coverage is ensured through the underlay Macro (indoor/outdoor)
Small Cells are used to offload the Macro and provide additional resources and/or improve the
quality of experience

Coverage and Capacity


Coverage is not ensured through the underlay Macro (indoor/outdoor)
The areas has a high user density or high foot fall.

The process ensures that


Experience from more complex deployments is feedback to improve similar deployments in
the future.
Guidelines can by dynamically updated
16
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

SHUNTER
Based on the input from the Customer, an initial classification is made
between the different projects.

The classification will rely on the number of Small Cells which are to
deployed and on knowledge gained from already studied scenarios.

Three choices are offered:


GREEN (couple of Small Cells)
YELLOW (few Small Cells)
RED (many Small Cells)

17
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

HOW TO ESTIMATE THE # OF SMALL CELLS?


In a second step, the number of users that can be supported using the
Number of Small Cells for Coverage is to be calculated.

In the case it is below the number of users in the Enterprise, then the
case will be classified as
GREEN if the number of Small Cells is between 1-2 (or home cell)
YELLOW if the number of Small Cells is between 3 and 5 (5 being the number of
PSC allowed for Small Cells)

In any other cases, the classification will be RED

18
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Classification - GREEN
These are straight forward scenarios
No RF expertise is required
Profile should be configured by Maintenance team
A GREEN classified Scenario can be moved to YELLOW following the initial
Evaluation Phase or due to Performance Issues
It will rely on
Profiles and Deployment Guidelines

19
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Classification - YELLOW
This is complex scenarios where RF Knowledge is needed
RF Expertise is needed
A GREEN classified Scenario can be moved to YELLOW following the initial
Evaluation Phase or due to Performance Issues
It will rely on
An analysis of the location
Profiles and Deployment Guidelines
Known cases
Manual Planning can be done in case of Small Cell group

20
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Classification - RED
This is the most complex scenarios
RF Expertise is strongly required
A YELLOW classified Scenario can be moved to RED following the initial Evaluation
Phase or due to Performance Issues
It will rely on
Deep analysis
Walk tests / Detailed site survey
Simulations
Optimization steps

In the case KPIs target cannot be meet, an alternative solution is to be


provided

21
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Indoor Femto Cell Coverage design


Indoor RF design in shared carrier is driven by
Macro best server signal strength

To perform a RF design it is mandatory to evaluate this, to ensure indoor


layer must be above the highest macro RSCP value measured in indoor to
ensure the dominance

RSSI of macro layer in indoor

In some cases generally for high floor levels, macro radio quality can be
very poor as a high number of servers is detected, and it is very difficult to
match good macro RF design over all floors and alos in outdoor

22
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Indoor ENVIRONMENTS DESCRIPTION


Environment

Description

MoO

Moderately Open

Warehouse, Airport, Manufacturing

MiD

Mildly Dense

Retail, Office Space w/ approx 80%


cubes/20% hard-walled offices

MoD

Moderately Dense

Office Space w/ approx 50% cubes/50% hardwalled offices

Den

Dense

Hospital, Office Space w/ approx 20%


cubes/80% hard-walled offices

23
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

HOW TO ESTIMATE THE # OF SMALL CELLS?


Indoor COVERAGE SCENARIO (Shared carrier)
1700-2100 Mhz bands
Indoor
Environement

Moderately Open

Midly Dense

Moderately Dense

Dense

Femto Power
1W (7 dBi)
250 mW
100 mW
20 mW
1W (7 dBi)
250 mW
100 mW
20 mW
1W (7 dBi)
250 mW
100 mW
20 mW
1W (7 dBi)
250 mW
100 mW
20 mW

Outodoor
Macro
RSCP = -50
30 m
13 m
10 m
7m
21 m
10 m
8m
6m
16 m
8m
7m
5m
13 m
7m
6m
4m

Outodoor
Macro
RSCP = -60
55 m
25 m
19 m
13 m
37 m
18 m
14 m
10 m
27 m
14 m
11 m
8m
21 m
11 m
9m
7m

Outodoor
Macro
RSCP = -70
101 m
46 m
36 m
23 m
65 m
32 m
25 m
17 m
45 m
23 m
19 m
13 m
33 m
18 m
15 m
11 m

Outodoor
Macro
RSCP = -80
188 m
84 m
66 m
43 m
113 m
55 m
44 m
30 m
75 m
39 m
32 m
22 m
53 m
29 m
24 m
17 m

24
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Outodoor
Macro
RSCP = -90
347 m
156 m
122 m
79 m
197 m
96 m
77 m
52 m
124 m
64 m
52 m
37 m
84 m
46 m
38 m
27 m

Outodoor
Macro
RSCP = -100
642 m
288 m
226 m
147 m
344 m
167 m
134 m
91 m
206 m
106 m
87 m
61 m
134 m
73 m
61 m
44 m

HOW TO ESTIMATE THE # OF SMALL CELLS?


Indoor COVERAGE SCENARIO (dedicated carrier)
Compare to the shared carrier solution, there is nomore neighboring and
interference impact on outdoor network
The main challenge is to keep coverage inside the building avoiding outdoor UE to
be able to connect to Femto network

25
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Inter-Femto Cells distance


Indoor COVERAGE SCENARIO
Whatever indoor or outdoor femto deployment, distance between femto
depends essentially on service requested, or on the capacity required in
term of users/m2 which should be supported

If limitation is only coverage then inter small cell distance should be 2


times cell radius required to support service requested at cell edge

If capacity is the most constraining criterion then femto density should


be enough to support user desnity. In case for indoor, femto power
should be 20 mW or 100 mW

In indoor the minimum distance between small cells should be 10m,


having a lower distance may be induce too high inter-fmeto cell
interference

26
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

AGENDA

Item 1 | Introduction
Item 2 | Product Overview
Item 3 | Femto Indoor RF Guidelines
Item 4 | Femto Outdoor RF Guidelines

27
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Femto Outdoor deployment


Outdoor deployment 2 scenarios are possible

Femto cells are deployed on a dedicated carrier never resued by macrocell layer. There is no risk of interference, so no constraints

Femto cells are deployed in the spot area, but the carrier should be reused by the macro cell layer. A buffer zone should be applied in order to
avoid macro-layer interfering small cells. To avoid potential interference,
the channel can be re-used on macro cells whose RSCP received
levelanywhere in small cell cluster respects
Macro-cell RSCP < Femto RSCP - 10

28
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Femto Outdoor deployment


Shared Carrier Outdoor Femto deployment

To avoid DL interference from macro-cells layers in shared carrier


conditions, it is necessary to position outdoor femto cells in areas where
macro cells RSCP is lower than below recommendation at Femto position
to obtain at least 50 m Femto cell radius as best server

29
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

Femto Outdoor radius VS Macro signal level

M a c ro IS D = 5 0 0 m

M a c ro IS D = 1 7 3 2 m

90

350

0.25W
0.5W
1W
2W
5W

70

0.25W
0.5W
1W
2W
5W

300
Metrocell equivalent radius [m]

Metrocell equivalent radius [m]

80

60
50
40
30

250

200

150

100

20
50

10
0
-7 5

-7 0
-6 5
-6 0
-5 5
-5 0
M a x im u m m a c ro c e ll C P IC H R S C P a t m e t ro c e ll B S [ d B m ]

0
-9 5

-4 5

-9 0

-8 5
-8 0
-7 5
-7 0
-6 5
-6 0
-5 5
-5 0
M a x im u m m a c ro c e ll C P IC H R S C P a t m e t ro c e ll B S [ d B m ]

Deployment in low macro RSCP, or if this is not possible (e.g. in dense urban areas)
higher transmit powers required to achieve good metro cell coverage areas.

30
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

-4 5

LR MCO Trial case : Asiatique


2 LR MCO trial at AsiaTique for shared-carrier at good Macro signal
scenario

92

91

31
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

UE Measurement RSCP : AsiaTique Trial

Best RSCP without LR MCO

Best RSCP with LR MCO

32
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

UE Measurement EcNo : AsiaTique Trial

Best Ec/No
Ec/No Without LR MCO

Best Ec/No
Ec/No with LR MCO

33
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

LR MCO coverage on the road : Trisara Phuket


The objective is to improve coverage on the road near Trisara resort . There
is one Macro site nearby, but due to hilly terrain environment the macro
signal is not able to serve on these 2 road area.
LR MCO mouth on pole with daisy chain is planned as solution for this case

34
COPYRIGHT 2011 ALCATEL-LUCENT. ALL RIGHTS RESERVED.
ALCATEL-LUCENT INTERNAL PROPRIETARY USE PURSUANT TO COMPANY INSTRUCTION

LR MCO coverage on the road : Trisara Phuket


RSCP Coverage prediction : 2.5D model