Você está na página 1de 70

R

E
K
A
E
R
B
T
I
U
C
CIR CESSORIES
C
A
AND
Catalogue
2014-2015

9001
CE

your expert for circuit protection

Contents
Miniature Circuit Breaker
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.

SPL9 - 63series ............................................................................................. 7


SLB2 - 32 series ............................................................................................ 8
SLB3 - 63 series ............................................................................................ 9
DZ47 - 63 series ........................................................................................... 10
DZ47IL - 63 series ....................................................................................... 11
DZ47IL - 100 series ..................................................................................... 12
SL7 series ...................................................................................................... 13
SIB1 - 63 circuit breaker.............................................................................. 14
SBKN circuit breaker..................................................................................... 15
SHV series....................................................................................................... 16
SDX series ....................................................................................................... 17
S5SX, S5SJ series ......................................................................................... 18
SNT - 50 series............................................................................................... 19
SBH, SBH-P series ........................................................................................ 20
THQL, THQC, THQP, TQL .............................................................................. 21
MEM series ..................................................................................................... 22
QO series.......................................................................................................... 23

Hydraulic Magnetic Circuit Breaker


1.
2.

SA-G3, SF-G3 series ..................................................................................... 25


SLB-H series .................................................................................................. 26

DC Circuit Breaker
1.
2.
3.

DZ47DC series DC Circuit Breaker ............................................................ 28


SLB3DC series DC Circuit Breaker ............................................................ 29
SLB4DC series DC Circuit Breaker ............................................................ 30

www.miniature-circuit-breaker.com

Residual Current Circuit Breaker


1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.

SPL9LE series................................................................................................ 32
SLB2LE-32I series....................................................................................... 33
SLB2LE-32II series..................................................................................... 34
SLB3LE-63 series.......................................................................................... 35
DZ47LE-63 series.......................................................................................... 36
DZ47LE-100 series....................................................................................... 37
SNT-50L series.............................................................................................. 38
SF7 series........................................................................................................ 39
SPFIM series.................................................................................................. 40
S5SM1 series.................................................................................................. 41
SDX-LE series.................................................................................................. 42
SFIN series..................................................................................................... 43
SNFIN series................................................................................................... 44

Motor Protection Circuit Breaker


1.
2.

SGV2 series..................................................................................................... 46
DZ108 series................................................................................................... 47

Molded Case Circuit Breaker


1.
2.
3.
4.
5.
6.
7.

SCM1 series ................................................................................................... 49


SDPX series .................................................................................................... 54
SBE/S series ................................................................................................... 55
SNF-CW series .............................................................................................. 57
S3VL 160/S3VL 1series ............................................................................... 58
S3VT series ..................................................................................................... 59
SNS series ...................................................................................................... 60

Auxiliary Products for Circuit Breaker


1.
2.
3.
4.

QOD series Load Center................................................................................ 63


MEM series Consumer Unit.......................................................................... 65
SBD series Circuit Breaker Lockout .......................................................... 66
Circuit Breaker Finder................................................................................... 67

www.miniature-circuit-breaker.com

Company brief
As one of largest miniature circuit breaker manufacturers in China, Guangzhou Shilin Electrical Co., Ltd.
(CGSL) was establish in 1998, and located in Guangzhou, where Canton Fair is held twice a year.
As famous brand in electrical industry, CGSL now has been acknowledged by worldwide electricians and
contractors, as Expert in Circuit Protection.
During engaging in exploring international market, CGSL has not only invested in raising technology,
but also focusing on electrical safety and decorating property, making CGSL real Your Expert for Circuit
Protection. After these years development, CGSL has formed a big team for RD, design, molding,
production, test, packing, and transportation, making us offer you Quality Goods, Professional Services,
including our strong After Service, thus youre assured of our Quality and CGSL.

WHY US

99
99
99
99

we were ISO9001 proved and CE certified for our circuit breakers


our own molding workshop guaranteed good material anddelicate appearance
perfect circuit breaker performance makes us real Your Expert For Circuit Protection
great variety of goods for your choice, includingminiaturecircuitbreaker,residual current
circuit breaker, moulded case circuit breaker, hydraulic magnetic circuit breaker, and motor
protection circuit breaker
99 peripheral products supplied largely saved your whole purchasing time and cost,
containingcircuit breaker panels,breaker lockout, and alsocircuitbreakerfinder
99 any technical support available in model selection, installation, test, replacement, and etc.
99 long warrantyof 24 months from items shipment

Payment terms
All payment should be made in Euros or US Dollars. No matter what order amount, deposit is necessary for any
orders, otherwise production wont be arranged. Deposit should be made through T/T or Paypal. As for payment
cost, buyer should bear the part which occurs in his country, and seller will recover the remaining ones. Deposit
amount shall be determined by total order amount.

For sales more than 5,000 USD, a 30% deposit should be made.

For sales between 3,000 USD and 5,000 USD, 50% deposit is needed by T/T or Paypal.

For sales less than 3,000 USD, buyer should pay 100% in advance.

For remaining balance, we normally accept payment ways as below:


a. T/T, remaining balance should be made after copy of Billing of Lading
b. L/C, buyer should pay balance immediately after he bought the documents which is submitted by
seller, through banks
c. Paypal, same as T/T

or
e

LI
SHI

E
ER

fe
Sa

ty
&

CUIT BR

AK

CIR

so much

Miniature

Circuit Breaker

YEAR
warranty

Http://www.miniature-circuit-breaker.com
Email: Info@miniature-circuit-breaker.com

SPL9-63 series

Miniature
Circuit Breaker
Application

good quality
high performance
long-term use

SPL9-63 series miniature circuit breakers are


the most cost effective series MCB in China.
They are mainly used in lighting distribution
system of AC 50/60Hz, rated current up to
63A, normally protecting against overload
and short-circuit, also working as infrequent
switch-over of electrical apparatus and
lighting circuits.

Features
SPL9-63 series is designed to be larger than
other MCB in size
Body material PA66 is adopted for
dimensional stability and great mechanical
strength
Red copper parts and bimetallic wired coil
is equipped for excellent performance and
higher reliability
The working current can be up to 63A, and
voltage can reach 400V
Three tripping characteristics B, C, D is
optional
SPL9-63 series MCB is complying with IEC/
EN 60898-1 standard

Safety & so much more

SLB2-32 series
Miniature
Circuit Breaker
Application
SLB2-32 is developed based on 1P and 2P
miniature circuit breakers, but safer than 1P
circuit breaker, and smaller than 2P MCB.
It is also used for single-phase circuit of
AC50/60Hz, rated voltage up to 230V, as
overload and short-circuit protection. It is
largely applied in houses, hotels, apartments,
hospitals, factories and mines, as branch
switch, it has been the first choice for
residential houses. Also this MCB complies
with IEC/EN 60898-1 standard.

Features

Specification

SLB2-32 MCB is small size, compact


structure, and space saving
Two poles (1P+N) is configured, but with
width of only 18mm
MCB could be connected with both lines
(phase line and neutral line), which are cutoff simultaneously for more safety
MCB can be connected with 10mm2 round
copper conductors at maximum
TH35-7.5 type standard DIN-rail is adopted
for installation
IEC/EN 60898-1 standard is applied for
design and production

Model
SLB2-32
Poles
1P+N
Characteristics
C, D
Nominal current (A)
6, 10, 16, 20, 25, 32
Nominal voltage (V)
AC230
Frequency (Hz)
50/60
Rated breaking capacity
4500A
Standard
IEC/EN 60898-1
Remarks:
1. OEM and custom services is available;
2. Details of MCB should be informed before ordering;

Safety & so much more

SLB3-63 series

Miniature
Circuit Breaker
Application
SLB3-63 is newly developed MCB with
beautiful appearance and high performance.
It is working in normal lighting distribution
system for overload and short-circuit
protection. SLB3-63 MCB conforms IEC/EN
60898-1 standard.

Features
SLB3-63 MCB is designed to be beautiful and
novel
Colorful handles for SLB3-63 can be
customized
Better material is adopted for long-term use
MCB is complying with IEC/EN 60898-1
standard

Specification
Model

SLB3-63

Poles

1P, 2P, 3P, 4P

Characteristics

B, C, D

Nominal current (A)

6, 10, 16, 20, 25, 32, 40, 50, 63

Nominal voltage (V)

AC230/400

Frequency (Hz)

50/60

Rated breaking capacity

4500A

Standard

IEC/EN 60898-1

Remarks:
1. OEM and custom services is available;
2. Details of MCB should be informed before ordering;

Safety & so much more

DZ47-63 series
Miniature
Circuit Breaker
Application
DZ47-63 model MCB can be your best choice with
best price! This series MCB is mainly working for
overload and short-circuit protection in power
system of AC 50/60Hz, rated current up to 63A,
and also it can infrequently change-over electrical
apparatus and lighting circuits.

Features
DZ47-63 series is designed to be simple and
mini sized for space saving
The working current can be up to 63A, and
voltage can reach 400V
Tripping characteristics B and C is for
options
DZ47-63 is complying with IEC/EN 60898-1
standard

Specification
Model
DZ47-63
Poles
1P, 2P, 3P, 4P
Characteristics
B, C, D
Nominal current (A)
6, 10, 16, 20, 25, 32, 40, 50, 63
Nominal voltage (V)
AC230/400
Frequency (Hz)
50/60
Rated breaking capacity
4500A
Standard
IEC/EN 60898-1
Remarks:
1. OEM and custom services is available;
2. Details of MCB should be informed before ordering;

10

Safety & so much more

DZ47IL-63 series

Miniature
Circuit Breaker
Application
DZ47IL-63 circuit breaker is a new type circuit
breaker equipped with interlock mechanism inside.
It works as overload and short-circuit protection,
and also circuit switchover, with two circuit breakers
handles at opposite positions, that means one circuit
breaker is at ON position, the other one should be at
OFF position.

Features
DZ47IL-63 is composed with two circuit
breakers (one pole ~ 4 poles) and mechanical
interlock accessory
It is mainly used in situation with two main
circuits not allowed working together
DZ47IL-63 is largely applied to protect ATS
and stabilizer, also it can work as simple ATS
The breaker is featured with circuits changedover fast and safely
The installation is very easy, with connection
top in bottom out
Mechanical life can be up to 20000 times
It can be installed in standard TH35-7.5 steel
DIN rail, which makes it used in wide range

Specification
Model
DZ47IL-63
Poles
2P/1P+1P, 4P/2P+2P, 6P/3P+3P, 8P/4P+4P
Tripping characteristics
B, C, D
Rated current (A)
6, 10, 16, 20, 25, 32, 40, 50, 63
Rated voltage (V)
AC230/400
Frequency (Hz)
50/60
Rated breaking capacity (kA)
4
Remarks:
1. OEM and custom services is available for options;
2. Requirements should be informed before ordering;

Safety & so much more

11

DZ47-100 series
Miniature
Circuit Breaker
Application
DZ47-100 series MCB is working as overload
and short-circuit protection in commercial
and industrial lighting distribution system of
AC50/60Hz, working voltage up to 400V, rated
current reaching up to 100A. It can also switchover electrical apparatus and lighting circuits.
DZ47-100 circuit breaker is also complying with
IEC/EN 60898-1 standard.

Features
DZ47-100 is configured with flame
retardant and impact resistant casing
It is featured as high breaking capacity,
reliable characteristics, quick tripping and
long-term use
DZ47-100 is applicable to DIN-rail
installation
DZ47-100 is mainly applied in lighting and
motor distribution systems

Specification

MCB is complying with IEC/EN 60898-1


standard

Model
DZ47-100
Poles
1P, 2P, 3P, 4P
Characteristics
C, D
Nominal current (A)
63, 80, 100
Nominal voltage (V)
AC230/400
Frequency (Hz)
50/60
Rated breaking capacity
10000A
Standard
IEC/EN 60898-1
Remarks:
1. OEM and custom services is available;
2. Details of MCB should be informed before ordering;

12

Safety & so much more

SL7 series

Miniature
Circuit Breaker
Application
MCB SL7 is one series of XPOLE. This MCB is
designed with features of safer, simpler, and faster
installation. It is mainly used to protect electrical
circuits and equipments against overload and shortcircuit damage, also it can get source isolated.

Features
Tripping characteristics of C and D is for
choices
Type C SL7 is applicable to lighting and
some power circuits, type D is for power
circuits and other circuits with strong
induction
Tripping setting is very accurate
Breaking capacity can be up to 10kA
Handles in different colors are designed for
different current ratings
Extremely high capacity of current limiting
makes high selectivity possible
Double terminals is designed for both busbars and single conductor
Bus-bars can be used for both sides
Multi-functional accessories series is
available
It is also featured with any directions of
incoming wires
DC type SL7 is also available, mainly
for telecommunications and electric
locomotives
Circuit Breaker is complying with
IEC60898 and GB10963

Specification
Model

SL7

Poles

1P, 1P+N, 2P, 3P, 3P+N,


4P

Tripping
characteristics

B, C, D

Rated current (A)

0.5, 1, 2, 3, 4, 6, 10, 16,


20, 25, 32, 40, 50, 63

Rated voltage (V)

AC230/400

Frequency (Hz)

50/60

Rated breaking
capacity (kA)

10

Standard

IEC60898
GB10963

Remarks:
1. OEM and custom services is available
for options;
2. Requirements should be informed
before ordering;

Safety & so much more

13

SIB1-63 series
Miniature
Circuit Breaker
Application
SIB1-63 series MCB is largely used industrially,
commercially and residentially. With excellent
quality, reliability and colored handles for easy
identification, SIB1-63 is very popular among
designers, installers, and panel-builders.

Features
SIB1-63 is largely applied in commercial,
industrial and residential markets with
high performance

Specification
Model

SIB1-63

Poles

1P, 1P+N, 2P, 3P,


3P+N, 4P

Tripping
characteristics

B, C, D

It is featured with accurate overload and


short-circuit protection
Color (Red/Green) contact position
indicator gives excellent user experience

0.5, 1, 2, 3, 4, 6, 10, 13,


Rated current (A) 16, 20, 25, 32, 40,50,
63
Rated voltage (V)

AC230/400

Frequency (Hz)

50/60

Rated breaking
capacity (kA)

6, 10

Standard

IEC60898-1

Remarks:
1. OEM and custom services is available
for options;
2. Requirements should be informed
before ordering;

14

Dual terminal structure is designed for


connection safely, flexibly, and reliably
Colored toggle handles is designed for
different current ratings
3 position Din rail clamp is configured
Comprehensive range of accessories
supplied makes installation quick and
easy
SIB1-63 is complying with international
and national standards

Safety & so much more

SBKN circuit breaker

Miniature
Circuit Breaker
Application
SBKN series circuit breakers are mainly used in
AC50/60Hz lighting distribution system and motor
distribution system as overload and short-circuit
protection.

Features
Breaking capacities of 6kA and 10kA is for
choices
Quick making and breaking mechanism is
equipped
High fire-resistant and shockproof plastic
for case makes SBKN long-life and durable
Besides overload and short-circuit
protection, SBKN can also work as
infrequent switchover in equipment and
lighting circuit
MCB is complying with both international
and national standards

Specification
Model

SBKN

Poles

1P, 1P+N, 2P, 3P, 3P+N, 4P

Tripping characteristics

B, C, D

Rated current (A)

0.5, 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63

Rated voltage (V)

AC230/400

Frequency (Hz)

50/60

Rated breaking capacity (kA)

6, 10

Remarks:
1. OEM and custom services is available for options;
2. Requirements should be informed before ordering;

Safety & so much more

15

10

SHV series
Miniature
Circuit Breaker
Application
SHV series MCB is another high breaking capacity
set of miniature circuit breaker. It is working as
overload and short-circuit protection in normal
distribution system. Besides this, MCB is also
featured with improved operational safety, greater
convenience and lower operating cost.

Features
SHV series MCB is exquisite, small and
light, easy to operate
It is suitable for common installation with
switchboards and switching points of lowvoltage end circuits
SHV is mainly for alternating current (AC)
system, but also can be used for direct
current (DC) system with short-circuit
resistance reduced by about 20%
B, C, D tripping characteristics is optional
It is designed according to European
standard EN 60898

Specification
Model

1 pole
2 poles
3 poles
4 poles
Tripping characteristics
Rated current (A)
Rated voltage (V)
Frequency (Hz)
Rated breaking capacity (kA)
Standard
Remarks:

SHV1
SHV2
SHV3
SHV4
B, C, D
1~63
AC240
50/60
10
IEC/EN 60898

1. OEM and custom services is available for options;


2. Requirements should be informed before ordering;

16

Safety & so much more

11

SDX series

Miniature
Circuit Breaker
Application
SDX series MCB designed is suitable for power
circuits of AC50/60Hz, rated voltage up to
400V, rated current reaching 125A, protecting
distribution system against overload, short-circuit
damage.

Features
SDX is designed to arrange distribution in
rows with absolute freedom
Wide rating range is supplied to be 63A for
single modular per pole, 80A ~ 125A for
1.5 modular
Handle is configured to be I-ON/red and
O-OFF/green
Tripping characteristics of B, C and D is for
options
High breaking capacity is optional
IEC60898 standard and IEC60947-2
standard is complied
Model
Poles
Tripping characteristics
Rated current (A)
Rated working voltage Ue (V)
Rated insulation voltage Ui
Rated impulse withstand current Uimp (kV)
Breaking capacity Icn acco. to IEC 60898
Breaking capacity Icu acco. to IEC 60947-2
Standard breaking capacity Ics acco. to IEC 60947-2
Mechanical life
Electrical life
Remarks:
1. OEM and custom services is offered;
2. Requirements should be informed before ordering;

Specification
SDX
1P, 2P, 3P
B, C, D
1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
AC230/400
500V
6
127/230V
6000A
230/400V
6000A
127/230V
10kA
230/400V
10kA
100%
20000
10000

Safety & so much more

17

12

S5SX, S5SJ series


Miniature
Circuit Breaker
S5SX is very safe from finger touch and
touch by the back of the hand
Its combined terminal allows bus-bar
and feeder cable to be simultaneously
connected
Quick mounting is available with snap-on
and snap-in mechanism
Its handle locking device can effectively
prevents unauthorized operation

S5SX

S5SX is especially suitable for mounting


in flat distribution boards for building
installations
Tripping characteristics of A, B, C, D is for
options

S5SJ is mainly applicable in power


system of AC50/60Hz, rated voltage up to
230/400V, protecting against overload and
short-circuit damage
Rated currents of 6 amp, 10 amp, 13 amp,
16 amp, 20 amp, 32 amp are for choices
1P, 1P+N, 2P, 3P is available for options
It is designed exclusively for buildings
S5SJ is produced complying with
IEC60898-1

S5SJ

18

Safety & so much more

13

SNT-50 series

Miniature
Circuit Breaker
Application
This mini circuit breaker has model of SNT-50, SNT50 mini circuit breaker is called to be safety circuit
breaker, which is mainly used in circuit of AC 50Hz,
rated voltage up to 240V, rated current up to 32A,
its function is overload protection, and short circuit
safeguard with fuse, of course it can also work as
circuit changeover.

Features
Small, beautiful and delicate appearance
make it very popular among electrical
contractors
Its suitable distribution system is AC 50Hz,
rated voltage from 115V to 240V, rated
current up to 32A
Black and white colors is for choices
Case is optional
It is totally safety with two lines completely
disconnected

Specification
Model

SNT-50

Poles

2P

Rated current (A)

10, 16, 20, 25, 32

Rated voltage (V)

AC120/240

Frequency (Hz)

50/60

Rated breaking capacity (kA)

3000

Remarks:
1. Case is optional for SNT-50 circuit breaker;
2. OEM and custom services is available;
3. Details should be informed before ordering;

Safety & so much more

19

14

SBH, SBH-P series


Miniature
Circuit Breaker
Model: SBH
Poles: 1P, 2P, 3P
Rated current In (A): 6, 10, 16, 20, 25, 32,
40, 50, 63, 100
Rated voltage Un (V): AC110/220 (1P),
AC240/415 (2P), AC415 (3P)
Rated frequency: 50/60Hz
Rated breaking capacity: 3000kA
Electrical life: >6000 times
Mechanical life: 20000 times
Standard: IEC/EN 60898-1, BS 3871-Pt1

SBH

Model: SBH-P
Poles: 1P, 2P, 3P
Tripping characteristics: B, C, D
Rated current In (A): 6, 10, 16, 20, 25, 32,
40, 50, 63, 100
Rated voltage Un (V): AC110/220 (1P),
AC240/415 (2P), AC415 (3P)
Rated frequency: 50/60Hz
Rated breaking capacity: 3000kA
Electrical life: >6000 times
Mechanical life: 20000 times
Standard: IEC/EN 60898-1, BS 3871-Pt1

SBH-P

20

Safety & so much more

15

THQL, THQC, THQP, TQL

Miniature
Circuit Breaker
Application
This series breaker is small size, light weight,
strong case and good performance. It is mostly
used for circuit switchover, overload and short
circuit protection, residentially, commercially
and industrially. The breaker is complying with
IEC60947 standard.

THQL

Specification

THQC

THQP

Poles

1, 2, 3

Tripping characteristics

B, C, D

Nominal current (A)

6, 10, 15, 20, 30, 40, 50, 63, 100

Nominal voltage (V)

AC110/277, AC220/415

Frequency (Hz)

50/60

Rated breaking capacity (A)

3000, 4500, 6000

Mechanical life

20000

Electrical life

6000

Standard

IEC60898, BS3781-1

TQL

Remarks:
1. OEM and custom services is available;
2. Requirements should be informed before ordering;

Safety & so much more

21

16

MEM series
Miniature
Circuit Breaker
Application
MEM series MCB protects from overload and shortcircuit in household and industrial distribution
system.

Specification
Model

MEM

Poles

1P, 2P, 3P

Rated current
(A)

6, 10, 15, 20, 25,


30, 40, 50, 60

Rated voltage (V)

AC230/400

Frequency (Hz)

50/60

Tripping
characteristics

C, D

Rated breaking
current Inc

3kA

Electrical life

4000

Mechanical life

16000

Remarks:
1. OEM and custom service is available;
2. Details should be informed before
ordering;

22

Safety & so much more

QO series

17

Miniature
Circuit Breaker
Application
QO series MCB is usually used in lighting distribution
system as protection against short circuit and
overload in industry, commence and dwelling, and
also protect fractional electric motors.
Meanwhile, they are also used in turning on or off
the electric apparatus and lighting circuit under the
normal condition. This plug in MCB QO is produced
according to IEC 60898 standard.

Specification
Model
Poles

QO
1P, 2P, 3P, 4P

RatedCurrent(A)

1,2,3,4,6,10,16,20,25,32,40

RatedVoltage(V)

230/400

RatedFrequency

50/60Hz

BreakingCapacity(A)

6000

ElectricalLife

6000

Mechanical life

20000

50, 63

4500

Remarks:
1. OEM and custom services is available;
2. Details should be informed before ordering;

Safety & so much more

23

or
e

LI
SHI

E
ER

fe
Sa

ty
&

CUIT BR

AK

CIR

so much

Hydraulic Magnetic

Circuit Breaker

YEAR
warranty

Http://www.miniature-circuit-breaker.com
Email: Info@miniature-circuit-breaker.com

SA-G3, SF-G3 series

Hydraulic Magnetic
Circuit Breaker
Model: SA-G3
Poles: 1P, 2P, 3P (SA1-G3: 1P; SA2-G3: 2P;
SA3-G3: 3P)
Tripping characteristics: B, C, D
Rated current In (A): 3, 5, 6, 10, 16, 20, 25,
32, 40, 50, 63

SA-G3

Rated voltage Un (V): AC230/240 (1P),


AC400/415 (2P, 3P),
Rated frequency: 50/60Hz
Rated breaking capacity: 3000A
Standard: IEC/EN 157-1973, BS 3871
PART 1
Model: SF-G3
Poles: 1P, 2P, 3P (SF1-G3: 1P; SF2-G3: 2P;
SF3-G3: 3P)
Tripping characteristics: B, C, D
Rated current In (A): 3, 5, 6, 10, 16, 20, 25,
32, 40, 50, 63
Rated voltage Un (V): AC230/240 (1P),
AC400/415 (2P, 3P),
Rated frequency: 50/60Hz
Rated breaking capacity: 6000A
Standard: IEC/EN 157-1973, BS 3871
PART 1

SF-G3

Safety & so much more

25

SLB-H series
Hydraulic Magnetic
Circuit Breaker
Application
SLB-H series hydraulic magnetic circuit breaker is
mainly used in power system of AC 50/60Hz, rated
voltage of single phase pole and double pole up
to 240V, 3 pole up to 415V, against overload and
short-circuit, also working as infrequent equipment
switchover operation.

Features
SLB-H is widely used in computers and
peripherals, industrial automation device,
telecommunication equipment, UPS
uninterruptible power supply equipment,
locomotive, marine electrical system, lift
controlling system and mobile power supply
equipment
It is very suitable to withdraw strong
vibration and impact
SLB-H circuit breaker provides two
connection ways, screw type and plug in type

SLB-H130

Specification

It should be installed before panel


It complies with GB17701-1999 and
IEC60934: 1993 and C22.2 standards

Frame current Inm (A)


30
50
1 pole
SLB-H130
SLB-H150
Model
2 poles
SLB-H230
SLB-H250
3 poles
SLB-H330
SLB-H350
Rated current (A)
3.5~30
10~50
Rated voltage (V)
AC230
Frequency (Hz)
50/60
Rated breaking capacity
1kA
Standard
IEC60934: 1993
Remarks:
1. Handles color could be optional;
2. OEM and custom services is available for options;
3. Requirements should be informed before ordering;

26

Safety & so much more

YEAR
warranty

Http://www.miniature-circuit-breaker.com
Email: Info@miniature-circuit-breaker.com

or
e

LI
SHI

ty
&

E
ER

fe
Sa

Circuit Breaker

CUIT BR

AK

DC

CIR

so much

1 DZ47DC series DC Circuit Breaker


Application
DZ47DC series DC circuit breaker is mainly
applicable in circuits of rated voltage up to
110/220V for single pole and 220/440V for two
poles, rated current reaching 63A, working
as overload and short-circuit protection and
infrequent switch-over in DC circuits. It is largely
used in electric automobiles and photovoltaic
power generation. The item is strictly complying
with IEC 60898 standard.

Features
DZ47DC is designed in modular, easily combined
with auxiliary contact, alarm contact and shunt
release
Breaking and signal control in remote distance
can be provided working with some accessories
It is normally installed with standard TH35-7.5
steel DIN rail
DZ47DC is widely adopted in industries like
electric automobiles and photovoltaic power
generation
It is complying with standards IEC60898 and
GB10963

Specification
Model
Poles
Tripping characteristics
Rated current (A)
Rated voltage (V)
Rated breaking capacity (kA)
Standard

DZ47DC
1P, 2P
B, C, D
1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63
DC110/220 (1P), DC220/440 (2P)
10
IEC 60898, GB 10963

Remarks:
1. Any DC voltage within range is available for your choices;
2. OEM and custom services is available for options;
3. Requirements should be informed before ordering;

28

Safety & so much more

2 SLB3DC series DC Circuit Breaker


Application
SLB3DC series DC circuit breaker is mainly
used for DC circuits of rated voltage up to
250V, rated current reaching 40A, working
as overload and short-circuit protection and
infrequent switch-over in DC circuits.

Features
SLB3DC is designed in modular, easily combined with auxiliary contact, alarm contact
and shunt release
It can provide breaking and signal control in
remote distance, working with some accessories
SLB3DC is normally installed with standard
TH35-7.5 steel DIN rail
It is largely used in PV system, protecting
inverter equipments
SLB3DC is produced strictly according to
standards IEC60947.2

Specification
Model

SLB3DC

Poles

1P, 2P

Tripping characteristics

B, C, D

Rated current (A)

1, 2, 3, 6, 10, 16, 20, 25, 32, 40

Rated voltage (V)

DC125/250

Rated breaking capacity (kA)

Remarks:
1. Any DC voltage within range is available for your choices;
2. OEM and custom services is available for options;
3. Requirements should be informed before ordering;

Safety & so much more

29

3 SLB4DC series DC Circuit Breaker


Application

up to
DC 1000V
10 kA
BREAKING
CAPACITY

SLB4DC series DC circuit breaker is mainly


used for DC circuits of rated voltage up
to 1000V, rated current reaching 63A, as
overload and short-circuit protection and
infrequent switch-over in DC circuits.

Features
SLB4DC is designed to protect against both
overload and short circuit
It has extremely high short-circuit breaking
capacity
Contact position indicator is equipped for
SLB4DC
It provides both terminal type and pin/fork
bus-bar type connection
Rigid conductor max. 25mm2 can be connected
It is designed suitable for both panel mounting and standard 35mm DIN rail installing

Specification
Model
Poles
Tripping characteristics
Rated current (A)
Rated voltage (V)

SLB4D3
1P, 2P, 3P, 4P
B, C, D
1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63
DC12, DC48, DC110, DC220, DC250, DC400, DC500,
DC630, DC800, DC1000
6.2kV
10
6000
IEC/EN 60947-2

Rated impulse withstand voltage


Rated breaking capacity (kA)
Mechanical endurance
Standard
Remarks:
1. Any DC voltage within range is available for your choices;
2. OEM and custom services is available for options;
3. Requirements should be informed before ordering;

30

Safety & so much more

YEAR
warranty

Http://www.miniature-circuit-breaker.com
Email: Info@miniature-circuit-breaker.com

or
e

LI
SHI

ty
&

E
ER

fe
Sa

Circuit Breaker

CUIT BR

AK

Residual Current

CIR

so much

SPL9LE series
Residual Current
Circuit Breaker
With Overload
Application
SPL9LE series RCBO is mainly used in lighting
distribution system of AC 50/60Hz, rated current
up to 63A, normally protecting against electric
leakage, overload and short-circuit. It conforms
to IEC/EN 61009-1 standard.

Specification
Model

SPL9LE

Poles

1P+N, 2P, 3P, 3P+N, 4P

Characteristics

B, C, D

Nominal current (A)

6, 10, 16, 20, 25, 32, 40, 50, 60

Nominal voltage (V)

AC230/400

Frequency (Hz)

50/60

Rated residual operating current In (mA)

30, 50, 100, 300

Rated residual non operating current Ino

0.5In

Rated residual making and breaking capacity Im

2000A

Rated conditional breaking current Inc

6kA

Rated conditional residual breaking current Ic

6kA

Standard

IEC/EN 61009-1

Remarks:
1. OEM and custom services is available;
2. Details should be informed before ordering;

32

Safety & so much more

SLB2LE-32I series

Residual Current
Circuit Breaker
With Overload

Application
SLB2LE-32I RCBO is applicable in
single-phase residential houses with
rated voltage up to 230V, protecting
against electric leakage, overload and
short-circuit. It is complying with IEC/
EN 61009-1 standard.

Features
It is small size, compact structure and space
saving
Two poles (1P+N) is configured within width of
36mm
Two poles will be cut-off simultaneously for
more safety
Electric leakage protection is available even
when phase and neutral is connected reversely
Visual residual operating indicator is designed
with white for no leakage fault and red for
leakage fault
10mm2 round copper conductors could be
connected at maximum
TH35-7.5 type standard DIN-rail is adopted for
installation
IEC/EN 61009-1 standard is applied for design
and production

Specification
Model
Poles
Characteristics
Nominal current (A)
Nominal voltage (V)
Frequency (Hz)
Rated residual operating current In (mA)
Rated residual non operating current Ino
Rated residual making and breaking capacity Im
Rated conditional breaking current Inc
Rated conditional residual breaking current Ic
Standard
Remarks:
1. OEM and custom services is available;
2. Details should be informed before ordering;

Safety & so much more

SLB2LE-63
1P+N
B, C, D
6, 10, 16, 20, 25, 32
AC230
50/60
30, 50, 100, 300
0.5In
2000A
6kA
6kA
IEC/EN 61009-1

33

SLB2LE-32II series

Residual Current
Circuit Breaker
With Overload
Application
Single pole RCBO SLB2LE-32II is applicable in
single phase residential houses with rated voltage
up to 230V, and rated current up to 40A, mainly
protecting from electric shock and ground fault, also
working as overload and short-circuit protection.
RCBO SLB2LE-32II can be used as infrequent
circuit switchover with isolation function.

Specification
Model

SLB2LE-32II

Poles

1P+N

Tripping characteristics

B, C

Rated current (A)

6, 10, 16, 20, 25, 32

Rated voltage (V)

AC230

Frequency (Hz)

50/60

Rated residual operating current In (mA)

30, 50, 100, 300

Rated residual non operating current Ino

0.5In

Rated residual making and breaking capacity Im

2000A

Rated conditional breaking current Inc

6kA

Rated conditional residual breaking current Ic

6kA

Standard

IEC/EN 61009-1

Remarks:
1. OEM and custom service is available;
2. Details should be informed before ordering;

34

Safety & so much more

SLB3LE-63 series

Residual Current
Circuit Breaker
With Overload
Application
SLB3LE-63 circuit breaker is working in normal
lighting distribution system for electric shock ,
overload and short-circuit protection. SLB3LE-63
MCB conforms IEC/EN 61009-1 standard.

Specification
Model

SLB3LE-63

Poles

1P+N, 2P, 3P, 3P+N, 4P

Characteristics

B, C, D

Nominal current (A)

6, 10, 16, 20, 25, 32, 40, 50, 63

Nominal voltage (V)

AC230/400

Frequency (Hz)

50/60

Rated residual operating current In (mA)

30, 50, 100, 300

Rated residual non operating current Ino

0.5In

Rated residual making and breaking capacity Im

2000A

Rated conditional breaking current Inc

6kA

Rated conditional residual breaking current Ic

6kA

Standard

IEC/EN 61009-1

Remarks:
1. OEM and custom services is available;
2. Details should be informed before ordering;

Safety & so much more

35

DZ47LE-63 series
Residual Current
Circuit Breaker
With Overload
Application
DZ47LE-63 is a kind of residual current circuit
breaker with overload protection. It is mainly
working for electric leakage, overload and shortcircuit protection in power system of AC 50/60Hz,
rated current up to 63A.

Specification
Model

DZ47LE-63

Poles

1P+N, 2P, 3P, 3P+N, 4P

Characteristics

B, C, D

Nominal current (A)

6, 10, 16, 20, 25, 32, 40, 50, 60

Nominal voltage (V)

AC230/400

Frequency (Hz)

50/60

Rated residual operating current In (mA)

30, 50, 100, 300

Rated residual non operating current Ino

0.5In

Rated residual making and breaking capacity Im

2000A

Rated conditional breaking current Inc

6kA

Rated conditional residual breaking current Ic

6kA

Standard

IEC/EN 61009-1

Remarks:
1. OEM and custom services is available;
2. Details should be informed before ordering;

36

Safety & so much more

DZ47LE-100 series

Residual Current
Circuit Breaker
With Overload
Application
DZ47LE-100 series RCBO (residual current circuit
breaker with overload protection) is applicable in
circuits of AC50/60Hz, working voltage 230/400V,
rated current reaching up to 100A, protecting
against overload, short-circuit and electric shock.

Specification
Model

DZ47LE-100

Poles

1P+N, 2P, 3P, 3P+N, 4P

Tripping characteristics

C, D

Rated current (A)

63, 80, 100

Rated voltage (V)

AC230/400

Frequency (Hz)

50/60

Rated residual operating current In (mA)

30, 50, 100, 300

Rated residual non operating current Ino

0.5In

Rated residual making and breaking capacity Im

2000A

Rated conditional breaking current Inc

6kA

Rated conditional residual breaking current Ic

6kA

Standard

IEC/EN 61009-1

Remarks:
1. OEM and custom service is available;
2. Details should be informed before ordering;

Safety & so much more

37

SNT-50L series
Residual Current
Circuit Breaker
Application
SNT-50L RCCB is designed based on SNT-50
miniature circuit breaker. It is working as current
discharge protection in residential single-phase
distribution line, for electrical equipments, such as
heater, refrigerator, vending machines and etc.

Features
It is small size and exquisite
Pole design for choice is only 2P
Its applicable circuit is single-phase
AC50Hz, 115V/240V, current up to 32A
It works as current residual protection for
electrical equipments, preventing them to
be damaged
It behaves high capacity, and excellent
performance

Specification
Model
Poles
Rated current (A)
Rated voltage Un(V)
Frequency (Hz)
Rated making capacity Im(A)
Rated ultimate short-circuit breaking capacity Inc(A)
Rated residual operation current In (mA)
Rated residual non-operation current Ino (mA)
Electrical life
Mechanical life

SNT-50LE
2P
10, 16, 20, 25, 32
AC120/240
50/60
120V: 1500
240V: 1000
3000
In: 10A, 16A
In: 20A, 25A
In: 32A
In: 10A, 16A
In: 20A, 25A
In: 32A
Loaded
Unloaded
10000

Remarks:
1. OEM and custom services is availablel;
2. Details should be informed before ordering;

38

Safety & so much more

10
15
30
5
7.5
15
6000
4000

SF7 series

Residual Current
Circuit Breaker
Application
SF7 series is one RCCB series of XPOLE. SF7 is
designed with features of safer, simpler, and faster
installation. It is mainly used for fault current/
residual current protection and additional protection.

Features
SF7 is designed for fault current/residual
current protection and additional protection,
with tripping not related with main circuit
voltage
Unnecessary wrong trip caused by electronic
equipment on-off operation can be prevented
Multi-functional connecting terminals is
equipped for both bus-bars and single
conductor
Wide variety of tripping currents make
selective protection possible
It is also configured with contact situation
indicator
It is complying with IEC61008 (EN61008)
and GB16916.1

Specification
Model
Poles
Rated current (A)
Rated voltage (V)
Frequency (Hz)
Rated residual operating current In (mA)
Rated residual non operating current Ino
Tripping duration
Sensibility
Rated making and breaking capacity Im
Rated residual making and breaking capacity Im
Rated conditional breaking current Inc
Rated conditional residual breaking current Ic
Remarks:
1. OEM and custom services is available for options;
2. Requirements should be informed before ordering;

Safety & so much more

SF7
2P, 4P
16, 25, 40, 63, 80
AC230/400
50/60
10, 30, 100, 300, 500
0.5In
40ms delay minimum, selection type
AC type
800A
800A
6kA
6kA

39

SPFIM series
Residual Current
Circuit Breaker
Application
SPFIM series is another RCCB series of Xpole.
SPFIM is designed with features of safer,
simpler, and faster installation. It is designed to
provide isolation, switching and earth leakage
protection for electrical circuits.

Features
SPFIM is designed for fault current/
residual current protection and
additional protection, with tripping not
related with main circuit voltage
SPFIM is a series of compact residual
current devices, supplying a wide range
of applications
Various nominal currents is available for
choices
Comprehensive range of accessories is
equipped
4 pole SPFIM has real contact position
indicator
It is also featured with automatic resetting function
SPFIM is complying with IEC61008

Specification
Model
Poles
Rated current (A)
Rated voltage (V)
Frequency (Hz)
Rated residual operating current In (mA)
Sensibility
Rated conditional breaking current Inc
Standard

SPFIM
2, 4
16, 25, 40,63, 80, 100
AC240/415
50/60
10, 30, 100, 300, 500
AC type
10kA
IEC61008

Remarks:
1. OEM and custom services is available for options;
2. Requirements should be informed before ordering;

40

Safety & so much more

10

S5SM1 series

Residual Current
Circuit Breaker
Application
S5SM1 series RCCB is mainly working for
distribution system or electrical apparatus of
AC50/60Hz, rated voltage at AC230/400V, rated
current from 16A ~ 80A, protecting against leakage,
fire accident and isolation damaged.
It is safer and more reliable with
electromagnetic configure
S5SM1 adopts new connection way
It is designed with delicate appearance,
different with old types RCCB
S5SM1 is largely used in distribution system
of residential houses, and also industrial
field, such as hotels, office buildings, mining
enterprises.
It is complying with EN61008 and
DINVDE0664 standards

Model

S5SM1

Poles

1P+N, 3P+N

Rated current (A)

6, 10, 16, 25, 32, 40, 50, 63, 80

Rated voltage (V)

AC125/230 (1P+N), AC230/400 (3P+N)

Frequency (Hz)

50/60

Rated residual operating current In (mA)

30, 50, 75, 100, 300, 500

Rated residual non operating current Ino

0.5In

Sensibility

AC type

Rated making and breaking capacity Im

800A

Rated conditional breaking current Inc

10kA

Standard

EN61008, DINVDE0664

Remarks:
1. S5SM2, S5SM3 series are available for choices;
2. OEM and custom services is available for options;
3. Requirements should be informed before ordering;

Safety & so much more

41

11

SDX-LE series
Residual Current
Circuit Breaker
Application
SDX-LE series RCCB is suitable for power circuits
of AC50/60Hz, rated voltage up to 400V, rated
current reaching 125A, breaking the circuit in
the event of a residual current fault but doesnt
provide protection against overload.

Features
Wide rating range is supplied to be 63A
for single modular per pole, 80A ~ 125A
for 1.5 modular
SDX-LE is designed to arrange distribution
in rows with absolute freedom
Handle is configured to be I-ON/red and
O-OFF/green
Sensibility of AC type, A type and also Hpi
type is for your choices
It is complying with standard IEC610081

Specification
Model
Poles
Rated current (A)
Rated voltage (V)
Frequency (Hz)
Rated residual operating current In (mA)
Sensibility
Rated making and breaking capacity Im
Rated residual making and breaking capacity Im
Rated conditional breaking current Inc
Rated conditional residual breaking current Ic
Standard

SDX-LE
2P, 4P
16, 25, 40, 63, 80
AC400
50/60
10, 30, 100, 300
AC type, A type, Hpi type
500A
1000A
10kA
10kA
IEC61008

Remarks:
1. OEM and custom services is offered;
2. Requirements should be informed before ordering;

42

Safety & so much more

12

SFIN series

Residual Current
Circuit Breaker
Application
SFIN Residual Current Circuit Breaker without
over-current protection conforms to the standards
of GB16916.1, IEC1008, and BC4293. It is used
in the circuit of AC50 ~ 60HZ, single phase 230V,
three phase 415V in industrial &mining enterprises,
commercial building and housing for protection
from electric shock hazard, and also can be used
for circuits infrequent switchover under normal
conditions.
When the circuit works normally, residual current
operated circuit breaker is in on position , when
leakage or electric shock occurs in the circuit, the
current transformer generates a signal to make
electromagnetic release work, and cut off power
source within 0.1 second to prevent leakage.

Specification
Model

SFIN

Poles

2P, 4P

Rated current (A)

25, 40, 63, 100

Rated voltage (V)

AC230/240, AC400/415

Frequency (Hz)

50/60

Rated residual operating current In (mA)

30, 100, 300, 500

Rated residual non-operation current (Ino)

15, 50, 150, 250

Residual operating current scooper

0.51n-10In

Sensitivity

AC and pulsating DC

Short-circuit capacity(Icn)

3000A

Remarks:
1. OEM and custom service is available;
2. Details should be informed before ordering;

Safety & so much more

43

13

SNFIN series
Residual Current
Circuit Breaker
Application
Residual current device SNFIN is in conformity with
the standard of IEC61008. It can cut off fault circuit
immediately on the occasion of shock hazard or earth
leakage of trunk, thus, it is suitable to avoid shock
hazard and fire caused by earth leakage.
SNFIN is mainly suitable for use in varieties of
plants and enterprises, buildings with system of
1 phase 230Vand3phase400V50/60Hz. RCD
isnotsuitableforuseonDCpulsesystem.

Specification
Model

SNFIN

Poles

2P, 4P

Rated current (A)

16, 25, 40, 63, 80

Rated voltage (V)

AC400

Frequency (Hz)

50/60

Rated residual operating current In (mA)

10, 30, 100, 300

Rated making and breaking capacity Im

500A

Rated residual making and breaking capacity Im

1000A

Rated conditional breaking current Inc

10kA

Rated conditional residual breaking current Ic

10kA

Standard

IEC/EN 61008

Remarks:
1. OEM and custom service is available;
2. Details should be informed before ordering;

44

Safety & so much more

YEAR
warranty

Http://www.miniature-circuit-breaker.com
Email: Info@miniature-circuit-breaker.com

or
e

LI
SHI

ty
&

E
ER

fe
Sa

Circuit Breaker

CUIT BR

AK

Motor ProtecTion

CIR

so much

SGV2 series

Motor Protection
Circuit Breaker
Application
SGV2 series circuit breaker is suitable for power
circuit of AC50/60Hz, rated voltage up tp 690V,
rated current from 0.16A ~ 32A, protecting threephase squirrel-cage asynchronous motors against
overload, phase loss, and short-circuit, and also
working as infrequent motor starting. MPCB SGV2
is compact and small-size, with width only to be
45mm; and also it is offered both installations of
panel mounting and DIN rail type. SGV2 breaker
is conforming to IEC 60947-2 and IEC 60947-4-1
standards. It includes SGV2-M, SGV2-ME, SGV2PM, SGV2-RS types.

SGV2 - M

SGV2 - ME
Specification

SGV2-M/ME (press-button control)


Model
SGV2-M01/ME01
SGV2-M02/ME01
SGV2-M03/ME03
SGV2-M04/ME04
SGV2-M05/ME05
SGV2-M06/ME06
SGV2-M07/ME07
SGV2-M08/ME08
SGV2-M10/ME10
SGV2-M14/ME14
SGV2-M16/ME16
SGV2-M20/ME20
SGV2-M21/ME21
SGV2-M22/ME22
SGV2-M32/ME32

Standard rated power of three-phase motors


(AC50/60Hz, AC-3 category) (kW)

Rated
current
(A)

230V

380V

415V

440V

500V

660V

0.16
0.25
0.4
0.63
1
1.6
2.5
4.0
6.3
10
14
18
23
25
32

0.37
0.75
1.1
2.2
3
4
5.5
5.5
7.5

0.37
0.75
1.5
2.2
4
5.5
7.5
11
11
15

0.75
1.5
2.2
4
5.5
9
11
11
15

0.37
0.55
1.1
1.5
3
4
7.5
9
11
11
15

0.37
0.75
1.1
2.2
3.7
5.5
7.5
9
11
15
18.5

0.37
0.55
1.1
1.5
3
4
7.5
9
11
15
18.5
26

Setting current (A)


Thermal
release
0.14-0.16
0.16-0.25
0.25-0.40
0.40-0.63
0.63-1.00
1.00-1.60
1.60-2.50
2.50-4.00
4.00-6.30
6.00-10.0
9.00-14.0
13.0-18.0
17.0-23.0
20.0-25.0
24.0-32.0

Magnetic
release
1.9
3.0
4.8
7.2
12
19
30
51
78
138
170
220
320
350
420

Weight
(kg)

0.26

Remarks:
1. Water-proof box SGV2-MC02 (IP55) and SGV2-MC01 (IP41) is optional;
2. Other series MPCB, SGV2-PM (knob control), SGV2-RS (racker control, for motors with starting current spikes)
are also available for choices;
3. OEM and custom services is offered;
4. Requirements should be informed before ordering;

46

Safety & so much more

DZ108 series

Motor Protection
Circuit Breaker
Application
DZ108 series motor protection circuit breaker is
suitable for power circuit of AC40/60Hz, rated voltage
up tp 660V, rated current from 0.1A ~ 63A, protecting
three-phase distribution circuit, motors and other
electrical apparatus against overload, phase loss, and
short-circuit, and also working as infrequent motor
starting. It is conforming to IEC 947-2, IEC947-5-1
and VDE0660 standards.

Specification

Model

Standard rated
power of threeRated Rated phase motors
Pole voltage current (AC50/60Hz,
AC-3 category)
(V)
(A)
(kW)
220V 380V 660V

Setting current (A)

Life

Weight
(kg)

Thermal Magnetic
Mechanical Electrical
release release
1-1.6
19
1.6-2.5
30
2.5-4.0
48
4.0-6.3
75
6.3-10
120
0.525
8.0-12.5
150
10-16
190
12.5-20
240
16-25
300
22-32
380
0.1-0.16
1.9
0.16-0.25
3.0
0.25-0.40
4.8
4104
5000
0.40-0.63
7.2
0.63-1.00
12
1.00-1.60
19
1.60-2.50
30
2.00-3.20
38
0.30
2.50-4.00
48
3.20-5.00
60
4.00-6.30
75
5.00-8.00
96
6.30-10.0
120
8.00-12.5
150
10.0-16.0
192
14.0-20.0
240

DZ108-32/2GA00
1.6
DZ108-32/2HA00
2.5
DZ108-32/2JA00
4.0
DZ108-32/2KA00
6.3
DZ108-32/2LA00
10.0
10 10
3
DZ108-32/8LA00
12.5
DZ108-32/2MA00
16.0
DZ108-32/8MA00
20.0
DZ108-32/2NA00
25.0
DZ108-32/2PA00
32.0
DZ108-20/2BU00
0.16
DZ108-20/2CU00
0.25
DZ108-20/2DU00
0.4
3
660
DZ108-20/2EU00
0.63
DZ108-20/2FU00
1
DZ108-20/2GU00
1.6
DZ108-20/2HU00
2.5
DZ108-20/8HU00
3.2
1.5 1.5
1
DZ108-20/2JU00
4.0
DZ108-20/8JU00
5
DZ108-20/2KU00
6.3
DZ108-20/8KU00
8
DZ108-20/2LU00
10
DZ108-20/8LU00
12.5
DZ108-20/2MU00
16
DZ108-20/2NU00
20
Remarks:
1. Other series MPCB, SGV2-M, SGV2-ME, SGV2-PM, SGV2-RS are also available for choices;
2. OEM and custom services is offered;
3. Requirements should be informed before ordering;

Safety & so much more

47

or
e

LI
SHI

E
ER

fe
Sa

ty
&

CUIT BR

AK

CIR

so much

Molded Case

Circuit Breaker

warranty

Http://www.miniature-circuit-breaker.com
Email: Info@miniature-circuit-breaker.com

SCM1 series

Molded Case
Circuit Breaker
Application
SCM1 molded case circuit breakers (hereafter
simply referred to be breakers) are newly
developed breakers with international advanced
design and manufacturing technologies. The
breakers is mainly applicable in circuits of
AC50/60Hz, rated insulated voltage up to 800V,
rated working voltage up to 690V, rated working
current reaching 800A, protecting circuits and
equipment against damage from overload, shortcircuit, under-voltage, also working as infrequent
change-over of the circuits.

Features
According to Icu (Ultimate short-circuit
breaking capacity), breakers could be
clarified as C class (Basic type), L class
(Standard type), M class (higher breaking
capacity), and H class (highest breaking
capacity)
The breakers have features of small
volume, high capacity, short arcover
(some parts of zero arcover) and impact
resistance
The breakers could be installed both
horizontally and vertically
Isolation function is designed for the
breakers
The breakers is complying with standards
of GB 14048.2-2008 and IEC 60947-2

Safety & so much more

49

SCM1 series
Specification
Frame current Inm (A)

63

Model

SCM1-63L

Rated current In (A)

SCM1-63M

SCM1-63

6, 10, 16, 20, 25, 32, 40, 50, 63

Pole

Rated insulation voltage Ui (V)

AC800

Rated working voltage Ue (V)

AC400

AC690V
Ultimate short-circuit breaking
ability Icu (kA)

AC400V

25

50

18

35

DC250V
AC690V
Operating short-circuit breaking
ability Ics (kA)

AC400V
DC250V

Dimension (mmmmmm)

1357873.5

Frame current Inm (A)


Model

SCM1100C

Rated current In (A)

SCM1-100L

Rated insulation voltage Ui (V)

Ultimate shortcircuit breaking


ability
Icu (kA)
Operating shortcircuit breaking
ability
Ics (kA)

50

SCM1-100

SCM1100H

3
AC800

DC250
AC400

AC400
AC690

AC400

AC690V

AC400

20

AC400V

50

DC250V

20

25

35

AC690V

50

85

35

50

10

AC400V

35

DC250V

15

Dimension (mmmmmm)

SCM1-100M

10,16, 20, 25, 32, 40, 50, 63, 80,100


2

Rated working voltage Ue (V)

13510381.5

100
SCM1-100

Pole

1357881.5

1506586

18

22

1509268

1509286

15012286

Safety & so much more

1509286

SCM1 series
Frame current Inm (A)
Model

160
SCM1-160C

SCM1-160L

SCM1-160M

Rated current In (A)


Pole

AC400
AC690

AC400

AC690V

20
25

35

50

85
20

AC690V
AC400V

10
18

25

35

50

DC250V

15
16510786

16510786

165107103

Frame current Inm (A)


Model

SCM1-225

Pole

SCM1225C

SCM1225L

Rated insulation voltage Ui (V)

SCM1-225M

SCM1-225

SCM1-225H

AC800
DC250
AC400

AC400
AC690

AC400

AC690V

AC400

20

AC400V

50

DC250V

20

25

35

AC690V

50

85

35

50

10

AC400V

35

DC250V

15

Dimension (mmmmmm)

165107103

100, 125, 140, 160, 180, 200, 225


2

Rated working voltage Ue (V)

165142103

225

Rated current In (A)

Operating shortcircuit breaking ability


Ics (kA)

AC400

DC250V

Dimension (mmmmmm)

Ultimate short-circuit
breaking ability
Icu (kA)

AC800

Rated working voltage Ue (V)

Operating short-circuit
breaking ability
Ics (kA)

Rated insulation voltage Ui (V)

AC400V

SCM1-160H

100, 125, 140, 160


3

Ultimate short-circuit
breaking ability
Icu (kA)

SCM1-160

16575103

18

22

16510786

Safety & so much more

165107103

165142103

165107103

51

SCM1 series
Frame current Inm (A)

250

Model

SCM1-250L

SCM1-250M

Rated current In (A)

SCM1-250

180, 200, 225, 250

Pole

Rated insulation voltage Ui (V)

Operating short-circuit
breaking ability Ics (kA)

AC400
AC690

AC400

AC690V
AC400V

50

AC690V
AC400V

35
165107103

SCM1-400C

52

165107103

SCM1-400

SCM1-400H

AC800
AC400
AC690

AC400

AC690V

AC400

20
35

50

AC690V

Dimension (mmmmmm)

165142103

225, 250, 315, 350, 400

Rated working voltage Ue (V)

AC400V

65

SCM1-400M

Rated insulation voltage Ui (V)

Operating shortcircuit breaking


ability Ics (kA)

42
16510786

SCM1-400L

AC400V

100

400

Rated current In (A)

Ultimate shortcircuit breaking


ability Icu (kA)

65
10

Frame current Inm (A)

Pole

AC400

20

Dimension (mmmmmm)

Model

AC800

Rated working voltage Ue (V)


Ultimate short-circuit
breaking ability Icu (kA)

SCM1-250H

65

100

42

65

15
25

35

257150106.5

257150106.5

257150106.5

257198106.5

Safety & so much more

257150106.5

SCM1 series
Frame current Inm (A)

630

Model

SCM1-630C

SCM1-630L

Rated current In (A)


3

Rated insulation voltage Ui (V)

AC690V

AC400V

35

50

AC690V
AC400V

AC400

20
65

100

42

65

15
25

35

270182110

270182110

Frame current Inm (A)

270182110

270240110

270182110

800

Model

SCM1-800M

SCM1-800

Rated current In (A)

SCM1-800H

630, 700, 800

Pole

Rated insulation voltage Ui (V)


Rated working voltage Ue (V)

Operating short-circuit
breaking ability Ics (kA)

AC400
AC690

AC400

Dimension (mmmmmm)

Ultimate short-circuit
breaking ability Icu (kA)

SCM1-630H

AC800

Rated working voltage Ue (V)

Operating short-circuit
breaking ability Ics (kA)

SCM1-630

400, 500, 630

Pole

Ultimate short-circuit breaking


ability Icu (kA)

SCM1-630M

AC690V

AC800
AC400
AC690

75

100

50

65

20

AC400V

Dimension (mmmmmm)

AC400

30

AC400V
AC690V

280210115.5

Safety & so much more

280280115.5

280210115.5

53

SDPX series
Molded Case
Circuit Breaker
Application
SDPX series molded case circuit breaker is a new
generation of MCCB, whose appearance is goodlooking, mainly working for distribution system of
AC50/60Hz, rated voltage up to 500V and rated
current reaching up to 630A, as overload and
short circuit protection. This moulded case circuit
breaker is complying with IEC 60947-2 and IS
13947-2.

Model

SDPX-125

SDPX-250

Frame current Inm (A)

125

250

Rated current In (A)

25-125

125-250

Pole

Rated insulation voltage Ui (V)

500

690

Rated working voltage Ue (V)

AC500

AC600

AC230/240V~

22

60

AC400/415V~

16

36

440V~

10

30

480/500V~

25

600V~

20

690V~

16

250V

16

36

Ultimate short-circuit breaking ability Icu


(kA)

Rated short-circuit breaking service ability Ics (kA)

100

Electrical life

1000

Mechanical life

7000

7000

Dimension (mmmmmm)

12075.674

200105105

Remarks:
1. OEM and custom services is available;
2. Details should be informed before ordering;
3. SDPX-160, SDPX-630 is also available for your options;

54

Safety & so much more

SBE/S series

Molded Case
Circuit Breaker
Application
These series molded case circuit breaker is specially
working for commercial and industrial power system
with AC50/60Hz, rated working voltage up to 600V/
DC250V, rated current reaching up to 630A, with
function of protecting against overload and short
circuit. It is largely applied for system switching
and infrequent motor starting. It could be installed
with both front board and back board, and it also can
equip hand-operating apparatus or motor-operating
apparatus to control in a remote distance. Besides,
accessories for the breakers are available to avoid
voltage loss and under-voltage.
*SBE refers to economical series; SBS involves
standard series.

Specification
Frame current Inm (A)
2 poles
Model
3 poles
4 poles
Rated current (A)
Frequency (Hz)
Rated operation voltage (V)
Rated insulation voltage (V)
Rated impulse withstand voltage (kV)
AC220/240V
AC380V
Ultimate breaking
AC415V
capacity Icu(kA)
AC440/460V
AC480/500V
AC600V
Utilization category
Electrical endurance
Mechanical endurance

30
SBS-32
SBS-33
5, 10, 15, 20, 30

10
7.5
5
5
2.5
2.5

50
SBE-52
SBS-52
SBE-53
SBS-53
SBS-54
5, 10, 15, 20, 30, 40, 50
50/60
600
690
6
10
25
7.5
14
5
10
5
10
2.5
7.5
2.5
5
A
1500
8500

60
SBE-62
SBE-63
-

SBS-52
SBS-53
SBS-54
60

10
7.5
5
5
2.5
2.5

25
14
10
10
7.5
5

Remarks:
1. Both economical and standard series are available for your choices;
2. OEM and custom services is offered;
3. Details should be informed before ordering;

Safety & so much more

55

SBE/S series
Frame current Inm (A)

Model

100

225

2 poles

SBE-102

SBS-102

SBE-202

SBS-202

SBE-402

SBS-402

3 poles

SBE-103

SBS-103

SBE-203

SBS-203

SBE-403

SBS-403

4 poles

SBE-104

SBS-104

SBE-204

SBS-204

SBE-404

SBS-404

5, 10, 15, 20,


30, 40, 50, 60,
75, 100

15, 20, 30, 40,


50, 60, 75, 100

Rated current (A)

100, 125, 150, 175, 200,


225

Frequency (Hz)

50/60

Rated operation voltage (V)

600

Rated insulation voltage (V)

690

Rated impulse withstand voltage (kV)

Ultimate
breaking
capacity
Icu(kA)

400

AC220/240V

10

50

35

50

35

50

AC380V

7.5

25

18

25

30

42

AC415V

25

18

25

25

35

AC440/460V

25

18

25

25

35

AC480/500V

2.5

25

10

14

18

25

AC600V

2.5

14

7.5

10

18

22

Utilization category

Electrical endurance

1500

1000

4000

Mechanical endurance

8500

7000

1000

Remarks:
1. Both economical and standard series are available for your choices;
2. OEM and custom services is offered;
3. Details should be informed before ordering;

56

250, 300, 350, 400

Safety & so much more

SNF-CW series

Molded Case
Circuit Breaker
Application
SNF-CW series MCCB is designed to applicable in
distribution system of AC50/60Hz, rated working
voltage up to 400V, rated current reaching 630A, as
overload and short-circuit protection, also as circuit
changeover use. It can be also used for motors as
Motor Protection Circuit Breaker (MPCB).

Specification
Model
Poles
Frame current Inm (A)

SNF30-CW
2, 3
32

Rated current (A)

10, 16, 20,


25, 32

Frequency (Hz)
Rated operation voltage Ue (V)
Rated insulation voltage Ui (V)
AC230V
Rated ultimate
AC380V
short-circuit
AC400V
breaking
AC440V
capacity Icu
AC500V
(kA)
DC250V
AC230V
Rated ultimate
AC380V
short-circuit
AC400V
breaking
AC440V
capacity Icu
AC500V
(kA)
DC250V

SNF63-CW
2, 3
63
10, 16, 20,
25, 32, 40,
50, 63

5
5
5
2.5
2.5
2
2
2
1
1
-

5
5
5
2.5
2.5
2
2
2
1
1
-

SNF125-CW
2, 3
125

SNF250-CW
2, 3
250
125, 150,
50, 63, 75,
175, 200,
100, 125
225, 250
50/60
AC400, DC250
AC690
25
30
10
18
10
18
10
15
7.5
10
13
15
5
9
5
9
5
8
4
5
-

SNF400-CW
2, 3
400

SNF630-CW
2, 3
630

250, 300,
350, 400

500, 600,
630

35
25
25
25
15
25
18
18
18
10
-

50
35
35
35
18
35
25
25
25
10
-

NOTE:
1. SNF-CS, SNF-SS is also available for your options;
2. OEM and customs services is supplied here for you;
3. Details should be informed before ordering;

Safety & so much more

57

S3VL160X/S3VL1 series
Molded Case
Circuit Breaker
Application
S3VL MCCB performs very excellently in overload
and short-circuit protection, in the power range of
16A to 1600A. This moulded case circuit breaker
with communication is a best choice for the new
plants.

Features
S3VL MCCB is designed with compact
dimensions
With space-saving feature, it is used for
plants, generators and motors protection
Thermal-magnetic over-current release (16A
to 630A) and electronic over-current release
(63A to 1600A) is for choices
It is mounted and operated easily and simply
It is complying with IEC60947-2 standard

Specification
Model

S3VL160X/S3VL1

Poles

3, 4

Frame current Inm (A)

160

Rated current (A)

20~160

Frequency (Hz)

50/60

Rated operation voltage Ue (V)

AC690, DC500

Rated insulation voltage Ui (V)

AC800

Rated impulse withstand voltage (kV)

8
240V

Rated ultimate short circuit breaking capacity Icu (kA)/


Rated short-circuit service breaking capacity Ics (kA)

415V

55/55

440V

25/20

500/525

18/14

690

8/4

Remarks:
1. S3VL250/S3VL3, S3VL400/S3VL4, S3VL630/S3VL5 are also available for your options.
2. OEM and custom services is offered;
3. Requirements should be informed before ordering;

58

65/65

Safety & so much more

S3VT series

Molded Case
Circuit Breaker
Application
S3VT MCCB is designed for distribution range from
10A to 1600A, providing a smart way to protect
plants, transformers, generators and motors. The
breaker can be applied in both infrastructure area
and industrial switchgear technology, as incoming
and outgoing circuit breakers.

Features
S3VT MCCB is designed to protect both
system and motors
It is featured as modular design, userfriendliness, and also highly safety and
reliability
It is very flexible, components can be
combined in a modular way
Both 3 pole and 4 pole types is available for
choices
Over-current release type is microprocessor
based trip unit
MCCB conforms to standard IEC60947-2

Specification
Model
Poles
Frame current Inm (A)
Rated current (A)
Frequency (Hz)
Rated operation voltage (V)
Rated insulation voltage (V)
Ultimate short circuit breaking capacity Icu (kA)

Service short-circuit breaking capacity Ics (kA)


Rated short-circuit making capacity (peak value)
Mechanical endurance
Electrical endurance

230V
415V
500V
690V
230V
415V
500V
690V
415V

S3VT2
3, 4
250
100, 160, 200, 250
50/60
Max. AC690
AC690
60
36
16
10
30
18
8
5
75kA
30000
3000

Remarks:
1. S3VT1, S3VT3 is also available for your options.
2. OEM and custom services are supplied here.
3. Requirements should be informed before ordering.

Safety & so much more

59

SNS series
Molded Case
Circuit Breaker
Application
Compact SNS series molded case circuit breaker is
used for circuit range from 16A to 3200A, it is largely
applied in marine, airports, oil and gas, and also wind
mills.

Features
The Compact SNS range is available in 4
sizes only in order to homogenize installation
dimensions, thus reducing switchboard
dimensions and facilitating their installation:
volume, depth, pole pitch and fastening
points are the same for each size
The Compact SNS technology satisfies
all your needs from 16 to 3200 A, with
a breaking capacity from 36 to200 kA.
Equipped with electronic control units, the
Compact SNS circuit-breakers guarantee
protection and measurement of your
electrical installation
Compact SNS adapts to all your applications:
protection of DC and AC installations,
generator protection, motor protection,
applications in 1000 V, switch-disconnectors,
source changeover switches. With Compact
SNS you have the choice
Compact SNS evolves together with your
installation: interchangeable trip units,
standardized accessories, changing of
rating without disassembling the device and
addition of indication and control functions
make Compact SNS the most flexible
solution on the market
Compact SNS series molded case circuit
breaker is available for applications in
marine, airports, oil and gas, wind mills

60

Safety & so much more

SNS series
Model
Poles
manual

Control

fixed
Connections

plug-in
(on base)/
withdrawable
(on chassis)

SNS160

SNS250

toggle
direct or extended rotary handle
electric
front connection
rear connection

2, 3, 4

front connection

rear connection

40 C
65 C
Rated insulation voltage (V) Ui
Rated impulse withstand voltage (kV) Uimp
AC 50/60 Hz
Rated operational voltage (V) Ue
DC
Frame current Inm (A)

160
150

250
220

AC750
8
690
750
N
SX
H
220/240V
85
90
100
380/415V
36
50
70
Ultimate breaking capacity Icu (kA)
AC 50/60 Hz
440V
35
50
65
500V
30
36
50
525V
22
35
35
660/690V
8
10
10
DC solutions from 48 to 750 V and breaking capacity 85 and 100 kA
Service short-circuit breaking capacity Ics (%Icu)
100%
Suitability for isolation

Utilisation category
A
Mechanical endurance
440V In/2
40000
20000
In
40000
20000
Electrical endurance
20000
10000
Remarks:
1. SNS80, SNS100, SNS400, SNS630 is also available for your options.
2. OEM and custom services are supplied here.
3. Requirements should be informed before ordering.

Safety & so much more

61

or
e

LI
SHI

E
ER

fe
Sa

ty
&

CUIT BR

AK

CIR

so much

Auxiliary Products for

Circuit Breaker

warranty

Http://www.miniature-circuit-breaker.com
Email: Info@miniature-circuit-breaker.com

QOD series Load Center

Features

Application

It is widely used in distribution system with


safety and simplicity

QOD series load center is the basic solution


for power distribution residentially and
commercially. Power supply can be
distributed into branch circuit breakers QO
type, through this QOD load center.

QOD designed is mainly for residential and


commercial uses
It is specially for indoor uses
QOD load center supplies 1 ~ 8 ways for
wide choices (1, 2, 3, 4, 6, 8)
It has both single-phase and three-phase
types for applications
Load center is exclusively designed for
working with QO circuit breakers
It is made of cold-rolled steel material,
making itself strong and long-life
Corrosion resistant tin-plated aluminum
terminals is equipped for such load centers
Tripping indicators VISI-TRIP is supplied
for great user experience
Main lugs equipped is ready for feeding
QOD load center is of grey color

Specification
Way

1
QOD
1F

Model
Rated current (A)
System type
Rated voltage (V)
Frequency (Hz)
Rated breaking
capacity (A)
Minimum conductor
size for feeding lugs
Maximum conductor
size for feeding lugs
width
Dimensions
(mm/)

height
depth

2
QOD
1S

QOD
2F

QOD
2S

50
1P, 2W
127

2P, 3W
240/120

3
QOD QOD
3F
3S
100
3P, 4W
220Y/127

4
QOD
4F

6
QOD
4S

60

QOD
6F

QOD
QOD
6S
8F
100
2P, 3W
240/120

QOD
8S

60
10000

13.3mm2
6AWG
93/
127/
3.75
5.0
185/
157/
7.3
6.2

13.3mm2
6AWG
127/ 93/
5.0
3.75
185/ 157/
7.3
6.2

2.08mm2
14AWG
67.43mm2
13.3mm2
2/0AWG
6AWG
190/ 165/ 190/ 165/
7.5
6.5
7.5
6.5
210/ 188/ 210/ 188/
8.2
7.4
8.2
7.4
75/2.95

Safety & so much more

53.48 mm2
1/0AWG
227/ 200/
8.9
7.9
210/ 188/
8.2
7.4

53.48 mm2
1/0AWG
269/ 242/
10.6 9.5
210/ 188/
8.2
7.4

63

Circuit Breaker and Accessories

64

Safety & so much more

64

2 MEM series Consumer Unit


Application
Features
Surface type and plug-in design gives easy
and simply installation
MEM-1 consumer unit is for single-phase
system use, MEM-3 is for three-phase system

MEM consumer unit is an entrance facility


supplying power distribution and control
services with safety and reliability, for
residential, commercial and light industrial
applications. It can be for both indoor
and outdoor uses with DIN rail design.
MEM consumer unit is mainly serving
to switchover MCB, which is installed in
enclosure.

Main switch equipped is 100A isolator, RCCB


or RCCB plus isolator can be customized
They are made of cold-rolled steel, with
texture coating and thickness 0.6mm for
MEM-1 (1.2mm for MEM-3)
Galvanized mounting plate is configured,
with thickness 1.8mm and 2.0mm copper
bars for MEM-1 (2.5mm and 2.0mm copper
bars for MEM-3)

MEM-1

RAL7032/RAL2004 colors is for options


Consumer units can be open with angle up to
120

MEM-3

Specification
Model

MEM-1

MEM-3

Installation type

Surface

Surface

way

8 (4~42 optional)

Rated current (A)


System type

250
Single-phase

4 (4~42 optional)
three-phase250
three-phase

Frequency (Hz)

50/60

50/60

Rated breaking capacity (A)

10000

10000

Safety & so much more

65

SBD series Circuit Breaker Lockout


Application
SBD series circuit breaker lockout works
on a wide range of mini circuit breaks all
over the world, through experiments they
can work on at least 750 types of MCB.
The whole series of circuit breaker lockout
is complying with OSHA (occupational
safety & health administrations) standard.

SBD-D01

Features

SBD-D02

Universal designs can be suitable for


a wide range of mini circuit breakers
It is easy to lock circuit breakers
without any tools, just through a
button
Single pole and multi poles lockout
is available for options
SBD accomplishes safety tasks
together with safety padlocks
Glass filled nylon is used for circuit
breaker lock construction
SBD circuit breaker lockout
conforms to OSHA standard

SBD-D03

SBD-D04

Specification
Model

SBD-D01

SBD-D02

SBD-D03

SBD-D04

Description

MCB lockout
(pins outward)

MCB lock
(pins inward)

MCB lock
(pull rod type)

MCB lock
(stitches outward,
broadening)

Accommodate
handle width (cm)

<2

<2

>2

>2

Accommodate
poles of MCB

2, 3, 4

2, 3, 4

66

Safety & so much more

4 Circuit Breaker Finder


Application
Features
Automatically adjust sensitivity and
locate the breaker or fuse associated with
receptacle
Test socket if any wiring fault is existing
Configured with flashlight inside for use in
darkness
Both beep and visual (LED) indications
Low battery warning
Complies with safety standard
IEC 61010-1 CAT II 600V

Circuit Breaker Finder/Socket Tester


(SF3349) is designed to locate correct
circuit breaker or fuse and also test
socket. It is mainly applicable in
houses, offices, plants and etc.
SF3349 has two functions as below:
1. locating circuit breaker or fuse
associated with any receptacle
without tripping the breaker or
blowing the fuse
2. testing socket if wiring faults is
existing
Correct wiring
Missing earth (ground)
Missing neutral
Live & earth reversed
Live & neutral reversed
Open circuit

Applicable in houses, offices,


plants and etc.

The Circuit Breaker Finder/Socket


Tester has two componentsan AC
powered transmitter and a batterypowered receiver.

Specification
Working temperature

0C ~50C (32F ~122F)

Relative humidity

<80%
Receiver

198mm40mm50mm
7.80in.1.57in.1.97in.

Transmitter

71mm64mm55mm
2.80in.2.52in.2.17in.

Receiver

126g

Transmitter

63g

Dimensions

Weight
Power source

9V battery

Safety standard

IEC 61010-1

Safety & so much more

67

We still supply any support after sales in documents or technically, giving solutions to any
of your problems. Moreover, trouble-shooting visit is also possible when assembling and
testing problems largely happened in CKD cases. During warranty period, if something is
wrong with circuit breaker quality due to material, design and manufacture, well provide
freemaintenance and spare parts for replacement. Given that some customers buy in CKD
situation and assemble themselves,we will make detailedassembling and testing proposal for
you, sometimes may be proposals for your choices. All we do is creating more value for you.

For any problems, you can write to us for solutions,


well make the reply ASAP.

After Service Support


Technical support:

Tracking and delivery:

Support@miniature-circuit-breaker.com

Logistic@miniature-circuit-breaker com

You should also pay attention to

our warranty policy!


LIN
SHI

suppor
ts

24

months
warranty

For items failed because of our product material, design and manufacture problems, CGSL
will repair or replace the items free of charge, also covering the cost of both way freight;
of course for small quantity case, well compensate you directly on our cost, if you accept,
items could be sent together with next order, or decrease money directly from amount of
next order, it all depends to you.
However for failures because of improper operation, unauthorized access to the product,
lighting stroke and any other natural or man-made sabotage, CGSL doesnt supply any
replacement, but repair is available, as long as buyer assumes all the cost occurs.
CGSL also have a policy for items failed after guarantee period, we can also repair the
damaged items on request, but buyer should bear all the cost and expenses caused.
This perfect warranty policy makes our customers assured of our quality and CGSL.

Youll get
more than
paid!

Circuit Breaker

& Accessories

Guangzhou Shilin Electrical Co., Ltd.


Ershe Industrial Zone, Daxiang Village, Renhe Town,
Baiyun District, Guangzhou City, Guangdong Province, China
Tel: 0086-20-86033123 | Fax: 0086-20-86033163 | Cell: 0086-15818845922
Info@miniature-circuit-breaker.com | www.miniauture-circuit-breaker.com

Você também pode gostar