Você está na página 1de 40

Service Manual Supplement

VSWR Monitor for M-Cell6

E Motorola 1999
All Rights Reserved
Printed in the U.K.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

Copyrights, notices and trademarks


Copyrights
The Motorola products described in this document may include copyrighted Motorola computer
programs stored in semiconductor memories or other media. Laws in the United States and other
countries preserve for Motorola certain exclusive rights for copyright computer programs, including the
exclusive right to copy or reproduce in any form the copyright computer program. Accordingly, any
copyright Motorola computer programs contained in the Motorola products described in this document
may not be copied or reproduced in any manner without the express written permission of Motorola.
Furthermore, the purchase of Motorola products shall not be deemed to grant either directly or by
implication, estoppel or otherwise, any license under the copyrights, patents or patent applications of
Motorola, except for the rights that arise by operation of law in the sale of a product.

Restrictions
The software described in this document is the property of Motorola. It is furnished under a license
agreement and may be used and/or disclosed only in accordance with the terms of the agreement.
Software and documentation are copyright materials. Making unauthorized copies is prohibited by
law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored
in a retrieval system, or translated into any language or computer language, in any form or by any
means, without prior written permission of Motorola.

Accuracy
While reasonable efforts have been made to assure the accuracy of this document, Motorola
assumes no liability resulting from any inaccuracies or omissions in this document, or from the use
of the information obtained herein. Motorola reserves the right to make changes to any products
described herein to improve reliability, function, or design, and reserves the right to revise this
document and to make changes from time to time in content hereof with no obligation to notify any
person of revisions or changes. Motorola does not assume any liability arising out of the application
or use of any product or circuit described herein; neither does it convey license under its patent
rights of others.

Trademarks

MOTOROLA and M-Cell are trademarks of Motorola Inc.


OSF/1, Motif, UNIX and the X device are registered trademarks in the United States and other
countries, IT DialTone and the Open Group are trademarks of The Open Group.
X Window System, X and X11 are trademarks of the Massachusetts Institute of Technology.
Looking Glass is a registered trademark of Visix Software Ltd.
Ethernet is a trademark of the Xerox Corporation.
Wingz is a trademark and INFORMIX is a registered trademark of Informix Software Ltd.
SUN, SPARC, and SPARCStation are trademarks of Sun Microsystems Computer Corporation.
IBM is a registered trademark of International Business Machines Corporation.
HP is a registered trademark of Hewlett Packard Inc.
Netscape and Netscape Navigator are registered trademarks of Netscape Communications
Corporation in the United States and other countries. Netscapes logo and product and service names
are also trademarks of Netscape Communications Corporation, which may be registered in other
countries.
Windows NT is a registered trademark of Microsoft Corporation.

ii

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

First aid in case of electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Reporting safety issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Warnings and cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Human exposure to radio frequency energy (PCS1900 only) . . . . . . . . . . . . . . . . . . . . . .

Beryllium health and safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Devices sensitive to static . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Chapter 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General description of the VSWR monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Introduction to the VSWR monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Purpose of the VSWR monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VSWR monitoring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11
11
11
12

RF configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single VM configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multiple VM configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13
13
13
14

VM alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Individually wired VM alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial linked VM alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15
15
15
15

Chapter 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Preparing to install the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Introduction to VM installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Choosing a location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tools and equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21
21
21
21
21

Installing the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable loss compensation jumper settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting the RF cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VM Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VM Power connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22
22
22
23
23
23
23

Testing the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24
24
24

Chapter 3
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction to VM maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symptoms of a defective VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31
31
31

Maintenance procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing a defective VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32
32
32

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

iii

iv

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

First aid in case of electric shock

First aid in case of electric shock


Warning
WARNING
Do not touch the victim with your bare hands until the electric circuit is
broken.
Switch off. If this is not possible, protect yourself with dry insulating
material and pull or push the victim clear of the conductor.

Artificial
respiration
In the event of an electric shock it may be necessary to carry out artificial respiration.
Send for medical assistance immediately.

Burns treatment
If the patient is also suffering from burns, then, without hindrance to artificial respiration,
carry out the following:

5th Feb 99

1.

Do not attempt to remove clothing adhering to the burn.

2.

If help is available, or as soon as artificial respiration is no longer required, cover


the wound with a dry dressing.

3.

Do not apply oil or grease in any form.

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

Reporting safety issues

Reporting safety issues


Introduction
Whenever a safety issue arises, carry out the following procedure in all instances.
Ensure that all site personnel are familiar with this procedure.

Procedure
Whenever a safety issue arises:

1.

Make the equipment concerned safe, for example, by removing power.

2.

Make no further attempt to tamper with the equipment.

3.

Report the problem directly to GSM Customer Network Resolution Centre


+44 (0)1793 430040 (telephone) and follow up with a written report by fax
+44 (0)1793 430987 (fax).

4.

Collect evidence from the equipment under the guidance of the Customer Network
Resolution Centre.

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Warnings and cautions

Warnings and cautions


Introduction
The following describes how warnings and cautions are used in this manual and in all
manuals of the Motorola GSM manual set.

Warnings
Definition
A warning is used to alert the reader to possible hazards that could cause loss of life,
physical injury, or ill health. This includes hazards introduced during maintenance, for
example, the use of adhesives and solvents, as well as those inherent in the equipment.

Example and format


WARNING
Do not look directly into fibre optic cables or optical data in/out connectors.
Laser radiation can come from either the data in/out connectors or
unterminated fibre optic cables connected to data in/out connectors.

Cautions
Definition
A caution means that there is a possibility of damage to systems, or individual items of
equipment within a system. However, this presents no danger to personnel.

Example and format


CAUTION
Do not use test equipment that is beyond its calibration due date when testing
Motorola base stations.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

General warnings

General warnings
Introduction
Observe the following warnings during all phases of operation, installation and
maintenance of the equipment described in the Motorola GSM manuals. Failure to
comply with these warnings, or with specific warnings elsewhere in the Motorola GSM
manuals, violates safety standards of design, manufacture and intended use of the
equipment. Motorola assumes no liability for the customers failure to comply with these
requirements.

Warning labels
Personnel working with or operating Motorola equipment must comply with any warning
labels fitted to the equipment. Warning labels must not be removed, painted over or
obscured in any way.

Specific
warnings
Warnings particularly applicable to the equipment are positioned on the equipment and
within the text of this manual. These must be observed by all personnel at all times when
working with the equipment, as must any other warnings given in text, on the illustrations
and on the equipment.

High voltage
Certain Motorola equipment operates from a dangerous high voltage of 230 V ac single
phase or 415 V ac three phase mains which is potentially lethal. Therefore, the areas
where the ac mains power is present must not be approached until the warnings and
cautions in the text and on the equipment have been complied with.
To achieve isolation of the equipment from the ac supply, the mains input isolator must
be set to off and locked.
Within the United Kingdom (UK) regard must be paid to the requirements of the
Electricity at Work Regulations 1989. There may also be specific country legislation
which need to be complied with, depending on where the equipment is used.

RF radiation
High RF potentials and electromagnetic fields are present in the base station equipment
when in operation. Ensure that all transmitters are switched off when any antenna
connections have to be changed. Do not key transmitters connected to unterminated
cavities or feeders.
Refer to the following standards:
S

ANSI IEEE C95.1-1991, IEEE Standard for Safety Levels with Respect to Human
Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300GHz.

CENELEC 95 ENV 50166-2, Human Exposure to Electromagnetic Fields High


Frequency (10kHz to 300GHz).

Laser radiation
Do not look directly into fibre optic cables or optical data in/out connectors. Laser
radiation can come from either the data in/out connectors or unterminated fibre optic
cables connected to data in/out connectors.
4

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

General warnings

Lifting
equipment
When dismantling heavy assemblies, or removing or replacing equipment, the competent
responsible person must ensure that adequate lifting facilities are available. Where
provided, lifting frames must be used for these operations. When equipments have to be
manhandled, reference must be made to the Manual Handling of Loads Regulations
1992 (UK) or to the relevant manual handling of loads legislation for the country in which
the equipment is used.

Do not ...
... substitute parts or modify equipment.
Because of the danger of introducing additional hazards, do not install substitute parts or
perform any unauthorized modification of equipment. Contact Motorola if in doubt to
ensure that safety features are maintained.

Battery supplies
Do not wear earth straps when working with standby battery supplies.

Toxic material
Certain Motorola equipment incorporates components containing the highly toxic material
Beryllium or its oxide Beryllia or both. These materials are especially hazardous if:
S

Beryllium materials are absorbed into the body tissues through the skin, mouth, or
a wound.

The dust created by breakage of Beryllia is inhaled.

Toxic fumes are inhaled from Beryllium or Beryllia involved in a fire.

See the Beryllium health and safety precautions section for further information.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

Human exposure to radio frequency energy (PCS1900 only)

Human exposure to radio frequency energy (PCS1900 only)


Introduction
This equipment is designed to generate and radiate radio frequency (RF) energy. It
should be installed and maintained only by trained technicians. Licensees of the Federal
Communications Commission (FCC) using this equipment are responsible for insuring
that its installation and operation comply with FCC regulations designed to limit human
exposure to RF radiation in accordance with the American National Standards Institute
IEEE Standard C95.1-1991, IEEE Standard for Safety Levels with Respect to Human
Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300GHz.

Definitions
This standard establishes two sets of maximum permitted exposure limits, one for
controlled environments and another, that allows less exposure, for uncontrolled
environments. These terms are defined by the standard, as follows:

Uncontrolled environment
Uncontrolled environments are locations where there is the exposure of individuals who
have no knowledge or control of their exposure. The exposures may occur in living
quarters or workplaces where there are no expectations that the exposure levels may
exceed those shown for uncontrolled environments in the table of maximum permitted
exposure ceilings.

Controlled environment
Controlled environments are locations where there is exposure that may be incurred by
persons who are aware of the potential for exposure as a concomitant of employment, by
other cognizant persons, or as the incidental result of transient passage through areas
where analysis shows the exposure levels may be above those shown for uncontrolled
environments but do not exceed the values shown for controlled environments in the
table of maximum permitted exposure ceilings.

Maximum
permitted
exposures
The maximum permitted exposures prescribed by the standard are set in terms of
different parameters of effects, depending on the frequency generated by the equipment
in question. At the frequency range of this Personal Communication System equipment,
1930-1970MHz, the maximum permitted exposure levels are set in terms of power
density, whose definition and relationship to electric field and magnetic field strengths are
described by the standard as follows:

Power density (S)


Power per unit area normal to the direction of propagation, usually expressed in units of
watts per square metre (W/m2) or, for convenience, units such as milliwatts per square
centimetre (mW/cm2). For plane waves, power density, electric field strength (E) and
magnetic field strength (H) are related by the impedance of free space, 377 ohms. In
particular,
2
S + E + 377
377

H2

where E and H are expressed in units of V/m and A/m, respectively, and S in units of
W/m 2. Although many survey instruments indicate power density units, the actual
quantities measured are E or E2 or H or H2.
6

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Human exposure to radio frequency energy (PCS1900 only)

Maximum
permitted
exposure
ceilings
Within the frequency range, the maximum permitted exposure ceiling for uncontrolled
environments is a power density (mW/cm2) that equals f/1500, where f is the frequency
expressed in MHz, and measurements are averaged over a period of 30 minutes. The
maximum permitted exposure ceiling for controlled environments, also expressed in
mW/cm 2, is f/300 where measurements are averaged over 6 minutes. Applying these
principles to the minimum and maximum frequencies for which this equipment is intended
to be used yields the following maximum permitted exposure levels:
Uncontrolled Environment
1930MHz
Ceiling

1970MHz

Controlled Environment
1930MHz

1970MHz

1.287mW/cm 2 1.313mW/cm 2 6.433mW/cm 2 6.567mW/cm 2

If you plan to operate the equipment at more than one frequency, compliance should be
assured at the frequency which produces the lowest exposure ceiling (among the
frequencies at which operation will occur).
Licensees must be able to certify to the FCC that their facilities meet the above ceilings.
Some lower power PCS devices, 100 milliwatts or less, are excluded from demonstrating
compliance, but this equipment operates at power levels orders of magnitude higher, and
the exclusion is not applicable.
Whether a given installation meets the maximum permitted exposure ceilings depends, in
part, upon antenna type, antenna placement and the output power to which this
equipment is adjusted. The following example sets forth the distances from the antenna
to which access should be prevented in order to comply with the uncontrolled and
controlled environment exposure limits as set forth in the ANSI IEEE standards and
computed above.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

Human exposure to radio frequency energy (PCS1900 only)

Example
calculation
For a base station with the following characteristics, what is the minimum distance from
the antenna necessary to meet the requirements of an uncontrolled environment?
Transmit frequency

1930MHz

Base station cabinet output power, P

+39.0 dBm (8 watts)

Antenna feeder cable loss, CL

2.0dB

Antenna input power Pin

PCL = +39.02.0 = +37.0dB (5watts)

Antenna gain, G

16.4dBi (43.65)

Using the following relationship:


G + 4pr W
Pin
2

Where W is the maximum permissible power density in W/m2 and r is the safe distance
from the antenna in metres, the desired distance can be calculated as follows:
r+

GPin
+ 43.65 5 + 1.16m
4pW
4p 12.87

where W = 12.87 W/m2 was obtained from table listed above and converting from
mW/cm 2 to W/m2.
NOTE
The above result applies only in the direction of maximum radiation of the
antenna. Actual installations may employ antennas that have defined radiation
patterns and gains that differ from the example set forth above. The distances
calculated can vary depending on the actual antenna pattern and gain.

Power density
measurements
While installation calculations such as the above are useful and essential in planning and
design, validation that the operating facility using this equipment actually complies will
require making power density measurements. For information on measuring RF fields for
determining compliance with ANSI IEEE C95.1-1991, see IEEE Recommended Practice
for the Measure of Potentially Hazardous Electromagnetic Fields - RF and Microwave,
IEEE Std C95.3-1991. Copies of IEEE C95.1-1991 and IEEE C95.3-1991 may be
purchased from the Institute of Electrical and Electronics Engineers, Inc., Attn:
Publication Sales, 445 Hoes Lane, P.O. Box 1331, Piscattaway, NJ 08855-1331,
(800) 678-IEEE or from ANSI, (212) 642-4900. Persons responsible for installation of this
equipment are urged to consult these standards in determining whether a given
installation complies with the applicable limits.

Other equipment
Whether a given installation meets ANSI standards for human exposure to radio
frequency radiation may depend not only on this equipment but also on whether the
environments being assessed are being affected by radio frequency fields from other
equipment, the effects of which may add to the level of exposure. Accordingly, the overall
exposure may be affected by radio frequency generating facilities that exist at the time
the licensees equipment is being installed or even by equipment installed later.
Therefore, the effects of any such facilities must be considered in site selection and in
determining whether a particular installation meets the FCC requirements.
8

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Beryllium health and safety precautions

Beryllium health and safety precautions


Introduction
Beryllium (Be), is a hard silver/white metal. It is stable in air, but burns brilliantly in
Oxygen.
With the exception of the naturally occurring Beryl ore (Beryllium Silicate), all Beryllium
compounds and Beryllium metal are potentially highly toxic.

Health issues
Beryllium Oxide is used within some components as an electrical insulator. Captive within
the component it presents no health risk whatsoever. However, if the component should
be broken open and the Beryllium Oxide, which is in the form of dust, released, there
exists the potential for harm.

Inhalation
Inhalation of Beryllium Oxide can lead to a condition known as Berylliosis, the symptoms
of Berylliosis are similar to Pneumonia and may be identified by all or any of the
following:
Mild poisoning causes fever, shortness of breath, and a cough that produces
yellow/green sputum, or occasionally bloodstained sputum. Inflammation of the mucous
membranes of the nose, throat, and chest with discomfort, possibly pain, and difficulty
with swallowing and breathing.
Severe poisoning causes chest pain and wheezing which may progress to severe
shortness of breath due to congestion of the lungs. Incubation period for lung symptoms
is 2-20 days.
Exposure to moderately high concentrations of Beryllium in air may produce a very
serious condition of the lungs. The injured person may become blue, feverish with rapid
breathing and raised pulse rate. Recovery is usual but may take several months. There
have been deaths in the acute stage.
Chronic response. This condition is more truly a general one although the lungs are
mainly affected. There may be lesions in the kidneys and the skin. Certain features
support the view that the condition is allergic. There is no relationship between the
degree of exposure and the severity of response and there is usually a time lag of up to
10 years between exposure and the onset of the illness. Both sexes are equally
susceptible. The onset of the illness is insidious but only a small number of exposed
persons develop this reaction.

First aid
Seek immediate medical assistance. The casualty should be removed immediately from
the exposure area and placed in a fresh air environment with breathing supported with
Oxygen where required. Any contaminated clothing should be removed. The casualty
should be kept warm and at rest until medical aid arrives.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

Beryllium health and safety precautions

Skin contact
Possible irritation and redness at the contact area. Persistent itching and blister
formations can occur which usually resolve on removal from exposure.

First aid
Wash area thoroughly with soap and water. If skin is broken seek immediate medical
assistance.

Eye contact
May cause severe irritation, redness and swelling of eyelid(s) and inflammation of the
mucous membranes of the eyes.

First aid
Flush eyes with running water for at least 15 minutes. Seek medical assistance as soon
as possible.

Handling
procedures
Removal of components from printed circuit boards (PCBs) is to take place only at
Motorola approved repair centres.
The removal station will be equipped with extraction equipment and all other protective
equipment necessary for the safe removal of components containing Beryllium Oxide.
If during removal a component is accidently opened, the Beryllium Oxide dust is to be
wetted into a paste and put into a container with a spatula or similar tool. The spatula/tool
used to collect the paste is also to be placed in the container. The container is then to be
sealed and labelled. A suitable respirator is to be worn at all times during this operation.
Components which are successfully removed are to be placed in a separate bag, sealed
and labelled.

Disposal
methods
Beryllium Oxide or components containing Beryllium Oxide are to be treated as
hazardous waste. All components must be removed where possible from boards and put
into sealed bags labelled Beryllium Oxide components. These bags must be given to the
safety and environmental adviser for disposal.
Under no circumstances are boards or components containing Beryllium Oxide to be put
into the general waste skips or incinerated.

Product life cycle


implications
Motorola GSM and analogue equipment includes components containing Beryllium Oxide
(identified in text as appropriate and indicated by warning labels on the equipment).
These components require specific disposal measures as indicated in the preceding
(Disposal methods) paragraph. Motorola will arrange for the disposal of all such
hazardous waste as part of its Total Customer Satisfaction philosophy and will arrange
for the most environmentally friendly disposal available at that time.
10

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

General cautions

General cautions
Introduction
Observe the following cautions during operation, installation and maintenance of the
equipment described in the Motorola GSM manuals. Failure to comply with these
cautions or with specific cautions elsewhere in the Motorola GSM manuals may result in
damage to the equipment. Motorola assumes no liability for the customers failure to
comply with these requirements.

Caution labels
Personnel working with or operating Motorola equipment must comply with any caution
labels fitted to the equipment. Caution labels must not be removed, painted over or
obscured in any way.

Specific cautions
Cautions particularly applicable to the equipment are positioned within the text of this
manual. These must be observed by all personnel at all times when working with the
equipment, as must any other cautions given in text, on the illustrations and on the
equipment.

Fibre optics
The bending radius of all fibre optic cables must not be less than 30 mm.

Static discharge
Motorola equipment contains CMOS devices that are vulnerable to static discharge.
Although the damage caused by static discharge may not be immediately apparent,
CMOS devices may be damaged in the long term due to static discharge caused by
mishandling. Wear an approved earth strap when adjusting or handling digital boards.
See Devices sensitive to static for further information.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

11

Devices sensitive to static

Devices sensitive to static


Introduction
Certain metal oxide semiconductor (MOS) devices embody in their design a thin layer of
insulation that is susceptible to damage from electrostatic charge. Such a charge applied
to the leads of the device could cause irreparable damage.
These charges can be built up on nylon overalls, by friction, by pushing the hands into
high insulation packing material or by use of unearthed soldering irons.
MOS devices are normally despatched from the manufacturers with the leads shorted
together, for example, by metal foil eyelets, wire strapping, or by inserting the leads into
conductive plastic foam. Provided the leads are shorted it is safe to handle the device.

Special handling
techniques
In the event of one of these devices having to be replaced observe the following
precautions when handling the replacement:
S

Always wear an earth strap which must be connected to the electrostatic point
(ESP) on the equipment.

Leave the short circuit on the leads until the last moment. It may be necessary to
replace the conductive foam by a piece of wire to enable the device to be fitted.

Do not wear outer clothing made of nylon or similar man made material. A cotton
overall is preferable.

If possible work on an earthed metal surface. Wipe insulated plastic work surfaces
with an anti-static cloth before starting the operation.

All metal tools should be used and when not in use they should be placed on an
earthed surface.

Take care when removing components connected to electrostatic sensitive


devices. These components may be providing protection to the device.

When mounted onto printed circuit boards (PCBs), MOS devices are normally less
susceptible to electrostatic damage. However PCBs should be handled with care,
preferably by their edges and not by their tracks and pins, they should be transferred
directly from their packing to the equipment (or the other way around) and never left
exposed on the workbench.

12

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Chapter 1

Overview

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

ii

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Chapter 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General description of the VSWR monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Introduction to the VSWR monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Purpose of the VSWR monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VSWR monitoring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11
11
11
12

RF configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single VM configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multiple VM configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13
13
13
14

VM alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Individually wired VM alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial linked VM alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15
15
15
15

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

iii

iv

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

General description of the VSWR monitor

General description of the VSWR monitor


Introduction to
the VSWR
monitor
This supplement describes the features of the EGSM 900 VSWR Monitor (VM) and how
it can be configured to suit most application requirements.

Purpose of the
VSWR monitor
The VM is for use in M-Cell6 Indoor (or equivalent) BTS systems. Each VM can monitor
the VSWR performance of a single BTS sector, assuming the sector has no more than
three antennas and there is only one Tx antenna in the sector. If duplexers are used then
additional VMs will be required.
The VM is designed to be installed in the Tx/Rx lines between the BTS and the antenna.
It monitors the RF signals by means of side-mounted dual directional couplers. An
integral mounting bracket is fitted to the base of the VM.
The VM requires an external 48 V dc power supply, which must be provided by the user.
Alarm outputs are provided to connect the VM to an external PIX alarm connector on the
BTS (refer to the appropriate section of the M-Cell6 Service Manual for information on
wiring alarm sensors to the PIX connector).
Figure 1-1 shows the main features of the VSWR monitor:
BTS RF COUPLERS (RX)

BTS RF COUPLER (TX)

DC POWER
CONNECTOR

ALARM
CONNECTOR

POWER
LED
ANTENNA RF COUPLERS
(RX)

ANTENNA RF COUPLER
(TX)

CABLE LOSS
COMPENSATION JUMPERS

ALARM
LEDs

MOUNTING
BRACKET

Figure 1-1 VSWR Monitor

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

11

General description of the VSWR monitor

VSWR
monitoring range
The relationship between the effective VSWR monitoring range with respect to the
insertion loss of the antenna cable (the distance between the VM and the antenna) can
be expressed as follows:
1.5:1 < VSWR < 1:1 with antenna cable loss = 0 2 dB
2:1 < VSWR < 1:1 with antenna cable loss = 2 3.5 dB
3:1 < VSWR < 1:1 with antenna cable loss = 3.5 5 dB
Jumpers are provided on the side of the VM to enable the user to select the most
appropriate setting to compensate for cable loss (see Installing the VM for further
information).

12

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

RF configurations

RF configurations
Introduction
Single or multiple VM configurations can be used, depending on the configuration of the
BTS sector.

Single VM
configurations
Only one VM is required for each BTS sector, provided each sector has no more than
three antennas and there is only one Tx antenna.
Figure 1-2 and Figure 1-3 illustrate typical RF configurations for a single VM.

ANT

BTS

RX
ANTENNA

RX2

RX2

RX
ANTENNA

RX1

RX1

TX
ANTENNA

TX

TX

RX
RX

RX
RX

TX
TX

VSWR Monitor

BTS sector

Figure 1-2 Simple three antenna (Tx + 2 x Rx) configuration

ANT

BTS

RX2

RX2

RX
ANTENNA

RX1

RX1

TX/RX
ANTENNA

TX

TX

RX
RX

TX/RX

VSWR Monitor

TX/RX

BTS sector

Figure 1-3 Two antenna (Tx/Rx + Rx) configuration

NOTE
Unused Rx ports on the VM do not require terminations.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

13

RF configurations

Multiple VM
configurations
If a sector uses two duplexers for both transmitting and receiving, then one VM will be
required for each Tx/Rx antenna, as shown in Figure 1-4.
ANT

BTS

RX2

RX2

RX1

RX1

TX

TX

TX/RX
TX/RX
ANTENNA

VSWR Monitor

ANT

BTS

RX2

RX2

RX1

RX1

TX

TX

TX/RX

TX/RX
TX/RX
ANTENNA

VSWR Monitor

TX/RX

BTS sector

Figure 1-4 Two antenna (Tx/Rx + Tx/Rx) configuration


NOTE
Unused Rx ports on the VM do not require terminations.

14

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

VM alarm connections

VM alarm connections
Introduction
There are two methods for connecting the alarm outputs from the VM to the BTS alarm
system. The method chosen depends on the users preference and the number of spare
alarm inputs available at the BTS.
Refer to the appropriate section of the M-Cell6 Service Manual for information on wiring
alarm sensors to the PIX connector on the BTS.

Individually
wired VM alarms
Each VM unit can be individually wired to a separate external BTS (PIX) alarm, as shown
in Figure 1-5.

VM #1

VM #2

ALARM
#1

ALARM
#2

VM #3

ALARM
#3

Figure 1-5 Separate VM alarms

Serial linked VM
alarm
The alarm outputs from all VMs can be wired together serially and presented as a single
summary BTS (PIX) alarm, as shown in Figure 1-6.

VM #1

VM #2

VM #3

SUMMARY
ALARM

Figure 1-6 VM summary alarm

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

15

VM alarm connections

16

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Chapter 2

Installation

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

ii

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Chapter 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Preparing to install the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Introduction to VM installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Part numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Choosing a location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tools and equipment required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21
21
21
21
21

Installing the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable loss compensation jumper settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting the RF cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VM Alarm connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VM Power connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22
22
22
23
23
23
23

Testing the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24
24
24

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

iii

iv

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Preparing to install the VM

Preparing to install the VM


Introduction to
VM installation
This part of the supplement provides all the information required to install the VSWR
Monitor (VM) and test that the VM is operating correctly.

Part numbers
SWUF6020

VSWR Monitor (includes dc input and alarm output cables)

SWKN6706

Set of three 1.0 m coaxial cables for the VM

SWKN6705

Set of three 1.5 m coaxial cables for the VM

SWKN6702

Set of three 2.0 m coaxial cables for the VM

SWKN6703

Set of three 2.5 m coaxial cables for the VM

SWKN6704

Set of three 3.0 m coaxial cables for the VM


NOTE

Cables of an appropriate length can be assembled on site if one of the above


sets of coaxial cables is not suitable. They will require straight DIN 7/16 male
connectors.
Although there is no maximum recommended length for the coaxial cables,
they should be kept as short as possible.

Choosing a
location
Choose a suitable location for mounting the VM, paying particular attention to the
following:
S

The orientation of the VM, so that the RF cable runs will be reduced to a minimum.

Easy access to the six coaxial connectors on the VM will be required.

The length of the coaxial cable set (if a set of pre-assembled coaxial cables is to
be used).

Availability of a 48 V dc power supply.

Tools and
equipment
required
The following tools/equipment are required to install the VM:

5th Feb 99

Cable connector crimping tools (for terminating the dc power input and alarm
output cables

Assembly tools for DIN 7/16 connectors (not required if a set of pre-assembled
coaxial cables is to be used).

Digital Multi-Meter (DMM) (for measuring open and closed circuits).

6 x M4 bolts or screws (not supplied with the VM).

A suitable socket wrench or screwdriver (depending on the type of bolts/screws


used to mount the VM).

A pair of snipe nose pliers (for removing and refitting the cable loss compensation
jumpers).

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

21

Installing the VM

Installing the VM
Safety
precautions
Read through the information contained in Warnings and cautions at the beginning of
this document before starting the installation procedure. This equipment must only be
installed by suitably qualified personnel.
Disable the transmitter RF power in the BTS sector to be fitted with the VM by using lock
device commands from the OMC or via a PC connected to the MCU. Check that the
orange Tx STATUS LEDs on the relevant TCUs are not lit before starting to disconnect
the RF cables.

Cable loss
compensation
jumper settings
Figure 2-1 shows the arrangement of the three cable loss compensation jumper blocks
on the side of the VM.
Off

3.5

Off

3.5

Off

3.5

JUMPER
BLOCK

TX

RX2

RX1

JUMPER
ALARM
LEDs

Figure 2-1 Arrangement of cable loss compensation jumper blocks on the VM


Set the position of the jumpers for each of the Rx and Tx connections according to the
information supplied in Table 2-1 below:

Table 2-1 Cable loss compensation jumper positions


Cable Loss (dB)

Jumper Position

VSWR Range

Monitoring OFF

Off

0.0 2.0

> 1.5:1

2.1 3.5

3.5

> 2.0:1

3.6 5.0

> 3.0:1

Set the jumpers to position 3.5 if the cable loss figure is not known.
Set the appropriate Rx jumper to Off if either of the Rx cables is to be left
disconnected, otherwise a false alarm will be generated for that signal line.
22

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Installing the VM

Mounting the VM
WARNING
Check that the BTS is unable to transmit RF power before disconnecting the
coaxial cables.
Disconnect the antenna coaxial cables from their connectors on the BTS and label them
for identification.
Mount the VM in the predetermined location and secure in position using the six bolts or
screws.

Connecting the
RF cables
Connect the RF cables using the following procedure:
1.

Connect one end of each of the new coaxial cables to the connectors on the BTS
side of the VM.

2.

Connect the other ends of the cables from the VM to the appropriate Tx or Rx
connectors on the BTS.

3.

Connect the coaxial cables that were previously disconnected from the BTS to the
appropriate connectors on the antenna side of the VM.

VM Alarm
connections
Plug the connector on the alarm cable into its socket on the VM (the connector will only
fit the socket in one position). If multiple VMs are to be connected, wire the alarm cables
in accordance with the preferred option (see VM alarm connections).
Connect the other end of the alarm cable(s) to the BTS. Refer to the appropriate section
of the M-Cell6 Service Manual for information regarding connecting external alarms to
the M-Cell6 BTS.

VM Power
connections
Plug the connector on the dc power cable into its socket on the VM (the connector will
only fit the socket in one position).
Connect the other end of the power cable to the local 48 V dc supply.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

23

Testing the VM

Testing the VM
General
The test procedure described below is designed to test that the VM is working and that
the built-in alarm circuits generate a fault signal when a fault condition is deliberately
induced.
Check that all connections have been made correctly and that the jumper settings are
correct before carrying out the test procedure.

Test procedure
The procedure for testing the VM is as follows:
1.

Switch on the 48 V dc power supply and check that the green dc power LED on
the VM is illuminated.

2.

Switch on the BTS transmitter to generate RF power and check that the three red
VM alarm LEDs are not lit.

3.

Disconnect the alarm input cable from the PIX connector on the BTS and connect
the DMM across the pair of contacts which form the alarm circuit from the VM.
(The pins used will depend on the alarm configuration chosen and the alarm wiring
configuration at the BTS.)

4.

Disconnect the Rx coaxial cables (one at a time) at the antenna connection points
for the site and check that the corresponding alarm LED on the VM is illuminated.
Check that the DMM reads an open-circuit of more than 100 k on each Rx alarm
circuit which is displaying an illuminated alarm LED.

5.

Reconnect the Rx cables. Check that the Rx alarm LEDs on the VM are not lit and
the DMM reads a short circuit of less than 1 .

6.

Disable transmitter RF power to the VM as described previously.


WARNING
Check that the BTS is unable to transmit RF power before disconnecting the
Tx cable.
Disconnect the Tx coaxial cable at the antenna connection points for the site,
restore transmitter power and check that the Tx alarm LED on the VM is
illuminated. Check that the DMM reads an open-circuit of more than 100 k on the
Tx alarm circuit.

7.

Disable transmitter RF power to the VM. Reconnect the Tx cable and then restore
transmitter power. Check that the Tx alarm LED on the VM is not lit and the DMM
reads a short circuit of less than 1 .

8.

Disconnect the dc input power cable from the VM. Check that the DMM reads an
open-circuit of more than 100 k.

9.

Disconnect the DMM and reconnect the alarm input cable to the BTS PIX
connector.

10.

Reconnect the dc input power cable to the VM.

The VM is now ready for operation.


24

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Chapter 3

Maintenance

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

ii

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Chapter 3
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting the VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction to VM maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symptoms of a defective VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31
31
31

Maintenance procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance philosophy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing a defective VM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32
32
32

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

iii

iv

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

5th Feb 99

Troubleshooting the VM

Troubleshooting the VM
Introduction to
VM maintenance
This part of the supplement provides all the information required to determine whether or
not a failure is due to a defective VSWR Monitor (VM) and how to replace a VM.

Symptoms of a
defective VM
Power failure
A VM internal power failure is indicated if the green dc power LED is not illuminated when
the external 48 V dc supply is connected and known to be working.

False alarms
For a true false alarm to occur (thus indicating a failure within the VM), all of the
following conditions must be met:
1.

A Tx/Rx alarm signal from the VM has been received by the BTS.

2.

The BTS is transmitting and receiving normally.

3.

The jumper settings for unused VM connections have been set to OFF (if
applicable).

4.

One or more of the alarm LEDs on the VM is illuminated.


NOTE
If conditions 1 to 3 above have been met but none of the alarm LEDs are
illuminated (condition 4), this indicates that the false alarm has been caused by
a fault in the alarm wiring and not the VM. This can be checked by carrying out
the test procedure described in Testing the VM.

5th Feb 99

Service Manual Supplement: VSWR Monitor for M-Cell6


68P02900W86-O

31

Maintenance procedures

Maintenance procedures
Maintenance
philosophy
The maintenance philosophy for the VM is to replace a defective unit with a new VM.
The VM does not contain any user-serviceable parts and defective units should be
returned to Motorola for repair.

Replacing a
defective VM
Safety precautions
Read through the information contained in Warnings and cautions at the beginning of
this document. This equipment must only be removed and replaced by suitably qualified
personnel.
Disable the transmitter RF power in the BTS sector to be fitted with the VM by using lock
device commands from the OMC or via a PC connected to the MCU. Check that the
orange Tx STATUS LEDs on the relevant TCUs are not lit before starting to disconnect
the RF cables.

Removal procedure
The procedure for removing a VM is as follows:
1.

Disconnect the 48 V dc supply from the VM.

2.

Disconnect the alarm cable from the VM.

3.

Label all RF cable connections to the VM and then disconnect the cables.

4.

Undo the mounting screws/bolts and remove the VM. Note the positions of the
cable loss compensation jumpers.

Replacement procedure
The replacement procedure is a reversal of the removal procedure. Remember to set the
cable loss compensation jumpers on the new VM to the same positions as on the
defective VM.

Testing
Once installed, the new VM must be tested as described in Testing the VM.

32