Escolar Documentos
Profissional Documentos
Cultura Documentos
AR120&AR150&AR160&AR200&AR500&AR510&A
R1200&AR2200&AR3200&AR3600 series
Enterprise Routers
08
Date
2015-05-08
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,
and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website:
http://enterprise.huawei.com
Issue 08 (2015-05-08)
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Description
Indicates an imminently hazardous situation
which, if not avoided, will result in death or
serious injury.
Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury.
Indicates a potentially hazardous situation
which, if not avoided, could result in
equipment damage, data loss, performance
deterioration, or unanticipated results.
NOTICE is used to address practices not
related to personal injury.
Issue 08 (2015-05-08)
ii
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Symbol
Description
Calls attention to important information, best
practices and tips.
NOTE
Change History
Changes between document issues are cumulative. The latest document issue contains all the
changes made in earlier issues.
Issue 08 (2015-05-08)
This issue has the following updates:
The following section is modified:
l
1 Router Overview
Issue 07 (2015-02-28)
This issue has the following updates:
The following section is added:
l
Issue 06 (2014-10-31)
This issue has the following updates:
The following section is added:
l
Router Overview
Issue 08 (2015-05-08)
iii
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Issue 05 (2014-10-20)
This issue has the following updates:
The following section is modified:
l
Issue 04 (2014-09-15)
This issue has the following updates:
The following section is added:
l
Router Overview
Issue 03 (2014-06-16)
This issue has the following updates:
The following sections are added:
l
Router Overview
Issue 02 (2013-12-31)
This issue has the following updates:
The following sections are modified:
l
Issue 01 (2013-10-30)
This is the first official release.
Issue 08 (2015-05-08)
iv
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Contents
Contents
About This Document.....................................................................................................................ii
1 Router Overview............................................................................................................................1
2 Preparing for Installation.............................................................................................................5
2.1 Reading Carefully the Safety Cautions..........................................................................................................................6
2.2 Checking Installation Environment................................................................................................................................7
2.3 Checking the Cabinet......................................................................................................................................................8
2.4 Checking the Power Supply...........................................................................................................................................9
2.5 Preparing Installation Tools..........................................................................................................................................11
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Contents
vi
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Contents
vii
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Contents
12 Maintaining a Router..............................................................................................................221
12.1 Replacing a Card......................................................................................................................................................222
12.2 Replace a Power Module..........................................................................................................................................223
12.3 Replace a Fan Module..............................................................................................................................................225
12.4 Replacing an Optical Module...................................................................................................................................226
12.5 Replacing a SIM Card (on a Card)...........................................................................................................................228
13 Hardware Troubleshooting...................................................................................................232
13.1 Power Supply Failures..............................................................................................................................................233
13.1.1 An AR Router Fails to Be Powered On.................................................................................................................233
13.1.2 The PWR Indicator Is Steady Red.........................................................................................................................233
13.2 Fan Failures..............................................................................................................................................................234
13.2.1 Fans Create Loud Noises and the STATUS Indicator Fast Blinks Red................................................................234
13.3 Card Failures.............................................................................................................................................................236
13.3.1 A Card Cannot Be Powered On.............................................................................................................................236
13.3.2 A Card Fails to Register After a Software Upgrade..............................................................................................237
13.3.3 A Card Resets Unexpectedly During Operating....................................................................................................237
13.4 Memory Failures.......................................................................................................................................................238
13.4.1 Failed to Write Data to the SD Card or USB Flash Drive.....................................................................................238
14 Appendix...................................................................................................................................239
14.1 Appendix A List of Indicators..................................................................................................................................240
14.2 Appendix B On-site Cable Assembly and Installation.............................................................................................242
14.2.1 Cable Assembly Precautions.................................................................................................................................242
14.2.2 Assembling Power Cables.....................................................................................................................................243
14.2.3 Assembling Ethernet Cables..................................................................................................................................252
14.2.4 Installing Cable Accessories..................................................................................................................................266
14.2.5 Replacing the Mold of the Crimping Tool............................................................................................................281
14.3 Appendix C Environmental Requirements for Device Operation............................................................................285
14.3.1 Environmental Requirements for an Equipment Room........................................................................................285
14.3.2 Requirements for Power Supply............................................................................................................................292
Issue 08 (2015-05-08)
viii
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Contents
Issue 08 (2015-05-08)
ix
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
1 Router Overview
Router Overview
Issue 08 (2015-05-08)
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
1 Router Overview
WiFi 0
ADSL
12V;5A
RESET
WiFi 1
FXS 3
FXS 1
FXS 2
FE1
FE2
FE3
FXO
FXS 0
FE0 WAN
CON/AUX
AR511GW-LAV2M3
PWR
SYS
USB
WWAN I
RSS
MODE
GPS N1
WLA N2
WLA
FI0
WI
FI1
WI
GE0
GE1
IV
E-D
AIN
E-M
3G/LT
3G/LT
GP
S
RESET
CONSOLE
micro SD
OTG
SIM1
SIM2
micro SD
AR511GW-LM7
AR513W-V3M8
GE1
RS485
RESET
GE0
USB0
AUDIO
Output
CONSOL
USB
(OTG)
AR1220
ON
OFF
FE4
FE1
FE0
GE0
FE2
FE5
FE6
~100-240
z;2A
V;50/60H
FE7
FE3
GE1
CON/AUX
AR2202-48FE
AR2202-
48FE
ON
OFF
;50/60Hz;3
~100-240V
+12V; 11.5A
LINK
LINK
ACT
LINK
ACT
Issue 08 (2015-05-08)
SA
ACT
E1
SLOT CARD
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
1 Router Overview
AR2204
AR2200
Series
+12V; 11.5A
EN
EN
ON
GE1
SYS
OFF
RPS
~100-2
/60Hz;3A
40V;50
ACT
micro SD
CON/AUX
RST
ACT
LINK
PWR
GE2
GE0
AR2220
AR2200
EN
EN
CON/AUX
Series
RST
ACT
ON
SYS
STATUS OFF
WR150A
micro SD
LINK
GE2
GE1
ACT
GE0
;50/60Hz;2A
~100-240V
AR2240
s
AR2200 Serie
STATUS
ON
OFF
~100-240V;
50/60Hz;5A
GE1
EN
GE1
GE2
GE0
ACT0 ACT1
micro SD
RST
EN
CON/AUX
LINK0 LINK1
ACT
SYS ACT
AR3260
s
AR3200 Serie
STATUS
ON
OFF
50/60Hz;5A
~100-240V;
GE1
EN
GE1
ACT0 ACT1
micro SD
SYS ACT
Issue 08 (2015-05-08)
RST
EN
CON/AUX
LINK0 LINK1
GE2
GE0
ACT
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
1 Router Overview
NOTE
l The procedures and methods for installing the AR120/AR150/AR160/AR200 series routers are the
same. This document uses the AR157VW as an example to describe the installation methods. For
details, see 3 Installing AR120/AR150/AR160/AR200 Series Routers.
l For details on how to installing an AR503GW-LM7 router, see 4 Installing an AR503GW-LM7
Router.
l For details on how to installing an AR509G-L-D-H router, see 5 Installing an AR509G-L-D-H
Router.
l The procedures and methods for installing the AR511GW-LAV2M3, and AR511GW-L-B3 routers are
the same. This document uses the AR511GW-LAV2M3 as an example to describe the installation
methods. For details, see 6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers.
l For details on how to installing an AR511GW-LM7 router, see 7 Installing AR511GW-LM7
Router.
l For details on how to installing an AR513W-V3M8 router, see 8 Installing an AR513W-V3M8
Router.
l The procedures and methods for installing the AR2201-48FE and AR2202-48FE routers are the same.
This document uses the AR2202-48FE as an example to describe the installation methods. For details,
see 9 Installing AR2201-48FE/AR2202-48FE Routers.
l The procedures and methods for installing the AR1200 series, AR2204, AR2220E and AR2220 routers
are the same. This document uses the AR1220 as an example to describe the installation methods. For
details, see 10 Installing the AR1200 Series/AR2204/AR2220E/AR2220 Routers.
l The procedures and methods for installing the AR2240, AR3260 and AR3670 routers are the same.
This document uses the AR2240 as an example to describe the installation methods. For details, see
11 Installing AR2240/AR3260/AR3670 Routers.
Issue 08 (2015-05-08)
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
DANGER
In case of fire, immediately leave the building or equipment deployment site and press the fire
alarm button or call the fire department. Never enter the building on fire again in any situation.
CAUTION
l Before performing any operation on a router, wear ESD clothing and ESD gloves or an ESD
wrist strap. Remove conductive objects like jewelry and watches.
l After installing the router on a cabinet/rack, connect the ground cable to the chassis before
any operations on the chassis and remove the ground cable only after you remove all the
other components and cables from the chassis.
Environmental Safety
DANGER
Do not place or operate the router in an environment with flammable or explosive gases or smoke.
NOTE
l Keep the router away from water or damp to prevent damages to circuits.
l The router heats during operation. The installation site must be well ventilated to ensure normal
operation of the router.
Issue 08 (2015-05-08)
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Electric Safety
DANGER
l Direct contact with a high-voltage power source or indirect contact through damp objects
can be fatal. Misoperations on high-voltage facilities may result in fire, electric shock, or
other accident.
l Never install or remove the router or power cables while the power is on. The electric arc or
spark generated between a power cable and conductor may cause a fire or eye damage.
l To protect personal and equipment safety, ground the router before powering it on.
Laser Safety
CAUTION
l Invisible laser beams will cause eye damage. Do not look into bores of optical modules or
connectors of optical fibers without eye protection.
l After unplugging an optical fiber, cover the fiber connectors with dust caps.
Mechanical Safety
CAUTION
l Before carrying a heavy object, use appropriate tools to protect yourself from bruise or sprain.
l Before pulling the chassis out of the cabinet, check whether there are any unstable or heavy
objects on the cabinet. Be careful not to make the objects fall, which may cause body injuries.
l Do not drill holes on a cabinet without permission. Unqualified holes on a cabinet affect the
electromagnetic filter performance of the cabinet and cause damages to the cables in the
cabinet. In addition, metal scraps may fall into the cabinet when you are drilling holes, causing
short circuit on printed circuit boards (PCBs).
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Requirement
Heat dissipation
Cleanness
ESD
Surge protection
Electromagnetic radiation
Issue 08 (2015-05-08)
Check Item
Requirement
Width
Installation space
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Check Item
Requirement
Grounding
Heat dissipation
Guide rail
Issue 08 (2015-05-08)
Check Item
Requirement
Preparation
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Check Item
Requirement
Voltage
Issue 08 (2015-05-08)
10
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
Tool
Function
Measuring
tape
Measures distances.
ESD wrist
strap
Prevents ESD
damages when you
touch or operate the
device or components.
Utility knife
Flat-head
screwdriver
Tightens or loosens
slotted screws.
Phillips
screwdriver
Tightens or loosens
cross recessed screws.
Marker
Diagonal
pliers
Multimeter
Tests cabinet
insulation, cable
connectivity, and
device electrical
performance
indicators including
voltage, current, and
resistance.
Picture
11
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
Tool
Function
Claw
hammer
Hammer
drill
Drills installation
holes on a wall.
Picture
12
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Installing AR120/AR150/AR160/AR200
Series Routers
Issue 08 (2015-05-08)
13
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
NOTICE
l Ensure that the desk is flat and properly grounded.
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Do not place other objects on the router.
Procedure
Step 1 Attach four rubber pads in the imprinted round areas marked plus (+) signs at the bottom of the
router.
ADSL
WiFi 1
CON/A
UX
FXS 3
FXS 2
FXS 1
FXS 0
WiFi 0
FXO
FE3
FE2
FE1
FE0 WA
N
RESE
T
12V;5A
Issue 08 (2015-05-08)
14
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
WiFi 0
ADSL
12V;5A
RESET
WiFi 1
FXS 3
FXS 2
FXS 1
FXS 0
FXO
FE3
FE2
FE1
FE0 WAN
CON/AUX
----End
DANGER
Before drilling holes on a wall, make sure that no power cable is routed in the wall. Otherwise,
power cables in the wall may cause personal injury.
NOTICE
l The interface side of a wall-mounted router must face down to protect interfaces from water.
l Screws must be installed solid in the wall; otherwise, the wall-mounted router may fall down
after cables are connected.
l Ensure that there are no flammable or explosive materials near the router and no obstructions
within 100 mm around the router.
l Install the router at an appropriate height to ensure that the indicators can be observed easily.
Measuring tape
Marker
Hammer drill
Claw hammer
Phillips screwdriver
Issue 08 (2015-05-08)
15
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Use a measuring tape to determine positions of two mounting holes, keep the two positions
aligned, and mark the positions with a marker.
130mm
Choose an appropriate drill bit according to the diameter of the mounting screws. The
diameter of the mounting screws cannot exceed 4 mm.
2.
3.
Use a Phillips screwdriver to screw the mounting screws into the wall anchors. Leave the
screws protruding 2 mm from the wall.
90
90
c
2mm
Step 3 Align the mounting holes on the rear of the router with mounting screws and hang the router on
the mounting screws.
Issue 08 (2015-05-08)
16
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
----End
NOTICE
l It is not recommended to install a Wi-Fi-capable router in a cabinet.
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Seen from the front panel of the router, the airflow of the router is left to right.
l If multiple routers are installed in a cabinet, it is recommended that at least 1 U of space (1
U = 44.45 mm) be kept between two routers. These routers must have the same airflow
direction; otherwise, heat dissipation is affected by hot air circulation.
Make sure the following before the installation:
l
The router installation position in the cabinet is determined and arranged properly.
The router to be installed is available and located near the cabinet for convenient movement.
Phillips screwdriver
Flat-head screwdriver
Issue 08 (2015-05-08)
17
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Floating nuts
Mounting brackets
M4 screws
M6 screws
NOTE
The mounting brackets, floating nuts, M4 screws, and M6 screws are not included in the installation
accessory package and need to be purchased separately.
Procedure
Step 1 Use a Phillips screwdriver to fix the mounting brackets to both sides of the router with M4
screws.
NOTE
The mounting brackets can be installed close to the front panel or rear panel.
WiFi 0
ADSL
12V;5A
RESET
WiFi 1
FXS 3
FXS 2
FXS 1
FXS 0
FXO
FE3
FE2
FE1
FE0 WAN
CON/AUX
Step 2 Install two floating nuts on each front mounting rail. Leave a mounting hole between the two
floating nuts on the same mounting rail.
NOTE
l The length of three adjacent mounting holes may not be 1 U. Observe the scale ticks on the mounting
rails when installing floating nuts.
l You can use a flat-head screwdriver to install floating nuts.
h4
1U
Issue 08 (2015-05-08)
Use the Phillips screwdriver to install M6 screws on the two lower floating nuts, and leave
2 mm of the screws out of the floating nuts.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
18
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3 Installing AR120/AR150/AR160/AR200 Series Routers
2.
Move the router into the cabinet with one hand supporting bottom of the router, and hook
the mounting bracket on the M6 screws.
3.
Use the Phillips screwdriver to tighten the lower M6 screws and then the upper M6 screws.
2m
m
b
WiFi 0
ADSL
12V;5A
RESET
WiFi 1
FXS 3
FXS 2
FXS 1
FXS 0
FXO
FE3
FE2
FE1
FE0 WAN
CON/AUX
----End
Antenna Type
AR151G-HSPA+7
3G whip antenna
AR151G-C
AR157G-HSPA+7
AR207G-HSPA+7
AR161FG-L
AR161FGW-L
AR169FGVW-L
AR161FW-P-M5
Issue 08 (2015-05-08)
19
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Model
Antenna Type
AR151W-P
AR156W
AR157W
AR157VW
AR158EVW
AR169FVW
AR201VW-P
AR207VW
3G whip antenna
3G remote antenna
l 3G remote antennas are not included in the installation accessory package and need to be purchased
separately.
l LTE remote antennas are not included in the installation accessory package and need to be purchased
separately.
Procedure
Step 1 Connect the antennas to the SMA connectors on the rear panel of the router.
WiFi 0
12V;5A
WIF
I
RESET
WiFi 0
ADSL
12V;5A
RESET
WiFi 1
FXS 3
FXS 2
FXS 1
WIF
I
FXS 0
FXO
FE3
FE2
FE1
FE0 WAN
WIF
I
CON/AUX
NOTE
The procedures and methods for installing different whip antennas on a router are the same. A Wi-Fi whip
antenna is used as an example here.
Step 2 Adjust positions of the antennas to obtain the optimal wireless transmission and receiving
performance.
Issue 08 (2015-05-08)
20
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
3G
3G
If the router is mounted on a wall, make the primary antenna parallel to the wall and
secondary antenna vertical to the wall.
It is recommended that you place the 3G remote antenna on the top of the cabinet, vertical to the
ground.
Issue 08 (2015-05-08)
21
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3 Installing AR120/AR150/AR160/AR200 Series Routers
3G MAIN
3G MAIN
3G remote antenna
WIFI
WIFI
If the router is placed on a desk, make the Wi-Fi antennas vertical to the desk.
If the router is mounted on a wall, make the Wi-Fi antennas parallel with the wall.
Issue 08 (2015-05-08)
22
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
WIFI
WIFI
----End
Issue 08 (2015-05-08)
23
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3 Installing AR120/AR150/AR160/AR200 Series Routers
WiFi 0
PoE
12V;2A
WiFi 1
FE3
CON/AUX
FE2
FE1
FE0 WAN
48V;2A
RESET
WAN FE
AP
AP
NOTE
l The following LAN interfaces support PoE power supply: FE0 to FE3 of the AR151W-P, FE0 to FE6
of the AR201VW-P and AR207V-P, and GE0 to GE3 of the AR161FW-P-M5 and AR169-P-M9.
l The methods for connecting a PoE power supply to different AR routers are the same. An AR151WP router is used as an example here.
The PoE power supply is not included in the installation accessory package and needs to be purchased
separately.
Procedure
Step 1 Connect one end of the PoE power supply to the PoE power jack of the router and the other end
to an AC power outlet.
Issue 08 (2015-05-08)
24
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
PoE
RESET
48V;2A
WiFi 0
PoE
12V;2A
WiFi 1
FE3
CON/AUX
FE2
FE1
FE0 WAN
48V;2A
RESET
WAN FE
AP
AP
----End
NOTICE
l The ground cable of a router must be correctly connected to protect the router against
lightning and interference.
l Do not power on the router before you finish connecting cables.
Phillips screwdriver
Multimeter
Ground cable
Issue 08 (2015-05-08)
25
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Connect the ground cable.
1.
Use a Phillips screwdriver to remove the M4 screw from the ground point on the rear panel
of the router. Keep the M4 screw in an appropriate place for later use.
2.
Align the M4 lug of the ground cable with the tapped hole on the ground point, and then
secure the ground cable with the M4 screw.
3.
Connect the M6 lug of the ground cable to a ground point on the desk, wall, or cabinet
where the router is installed.
ADSL
WiFi 1
CON/AUX
FXS 3
WiFi 0
FXS 2
FXS 1
FXS 0
FXO
FE3
FE2
FE1
RESET
FE0 WAN
12V;5A
Ground cable
12V;5A
12V;5A
----End
Follow-up Procedure
Perform the following operations after connecting the ground cable:
l
Check that the ground cable is securely connected to the ground points.
Use a multimeter to measure the resistance between the ground points at two ends of the
ground cable. The resistance must be smaller than 5 ohm.
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Issue 08 (2015-05-08)
26
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Console cable
NOTE
The console cable is not included in the installation accessory package and needs to be purchased separately.
Procedure
Step 1 Connect the console cable.
1.
Connect the RJ45 connector of the console cable to the CON/AUX interface (RJ45) of the
router.
2.
Connect the DB9 connector of the console cable to the serial interface (COM) of a
management PC.
CON/AUX
ADSL
WiFi 1
CON/AUX
FXS 3
WiFi 0
FXS 2
FXS 1
FXS 0
FXO
FE3
FE2
FE1
FE0 WAN
RESET
12V;5A
COM
Console cable
----End
Follow-up Procedure
After connecting the console cable, configure the serial port communication software on the
management PC, so that you can log in to the command line interface (CLI) of the router. The
following describes how to set the serial port communication software on the Windows XP and
Windows 7 operating systems.
l
Issue 08 (2015-05-08)
Windows XP
1.
2.
Create a connection, select a serial port, and configure the following parameter
settings:
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
27
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Click OK. The router copyright statement is displayed on the HyperTerminal. Enter
the default user account admin and password Admin@huawei as prompted to log in
to the CLI of the router.
Windows 7
The Windows 7 operating system does not provide the HyperTerminal. You can download
free HyperTerminal software, such as PuTTY, from the Internet. The following example
describes how to use the PuTTY software.
1.
Download the PuTTY software to the PC and double-click it to run the software.
2.
3.
4.
Click Open. The router copyright statement is displayed. Enter the default user
account admin and password Admin@huawei as prompted to log in to the CLI of
the router.
For details on how to log in to the router through the console interface, see Logging In to the
System for the First Time.
Issue 08 (2015-05-08)
28
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3 Installing AR120/AR150/AR160/AR200 Series Routers
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Diagonal pliers
Cable ties
Marker
Procedure
Step 1 Select Ethernet cables of appropriate quantity and lengths according to the number of ports and
measured cabling distances.
Step 2 Attach temporary labels to both ends of each Ethernet cable and write numbers on the labels to
identify the Ethernet cables. For details, see 14.5.3 Engineering Labels for Network Cables.
Step 3 Connect one end of an Ethernet cable to an Ethernet interface of the router and the other end to
an Ethernet interface of the remote device.
FE3
FE2
FE1
FE0 WAN
ADSL
WiFi 1
CON/AUX
FXS 3
WiFi 0
FXS 2
FXS 1
FXS 0
FXO
FE3
FE2
FE1
FE0 WAN
RESET
12V;5A
Network cable
Ethernet interface of
the remote device
Issue 08 (2015-05-08)
29
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Step 4 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 5 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm away
from the connectors at both ends.
----End
Follow-up Procedure
Check the following items after connecting Ethernet cables:
l
Labels are correctly filled and securely attached to cables, with texts facing the same
direction.
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on the router before you finish connecting the power cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
The AC power cable parameters vary in different countries or regions. The figures in this section are for
reference only and may differ from the cables delivered.
Power adapter
AC Power Cable
Procedure
Step 1 Verify that the router is reliably grounded.
Issue 08 (2015-05-08)
30
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3 Installing AR120/AR150/AR160/AR200 Series Routers
Step 2 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 3 Connect the power adapter.
NOTE
The router does not have a power switch, and its power supply is controlled by the power switch of the
external power supply system.
1.
Connect one end of the power adapter to the power socket on the router.
2.
12V;5A
ADSL
WiFi 1
CON/AUX
FXS 3
WiFi 0
FXS 2
FXS 1
FXS 0
FXO
FE3
FE2
FE1
FE0 WAN
RESET
12V;5A
AC Power Cable
AC power outlet
Insert the AC terminal locking latch into the jack on the rear panel of the router.
2.
3.
Issue 08 (2015-05-08)
31
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
----End
Follow-up Procedure
Perform the following operations after connecting the power adapter:
l
If multiple routers are installed, attach labels to both ends of each power cable and write
numbers on the labels to identify them.
32
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Context
Before you power on the router, check and ensure the following:
l
Procedure
Turn on the power switch of the power supply system to start the router.
After the router starts, check indicators on the front panel to check whether the router runs
normally. Figure 3-2 describes the indicator states when the router is running normally.
Figure 3-2 Normal indicator states on the router
PWR
SYS
USB
PPP
VPN
LINK
PWR
SYS
USB
PPP
VPN
ACT
ADSL
0
WLAN WAN
LAN
FXO
AR150 Series
Indicator
Description
PWR
SYS
NOTICE
Powering off the router will interrupt all the services on the router. Exercise caution when
you perform this operation.
Turn off the power switch of the power supply system.
----End
Issue 08 (2015-05-08)
33
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Follow-up Procedure
After the router starts, you can log in to its CLI to configure, manage, and maintain the router.
For details, see the CLI-based Configuration.
Wired mouse
Bluetooth mouse
Bluetooth keyboard
Procedure
Step 1 Connect a wired mouse to the USB (Host) interface of the router.
Step 2 Connect the router to a monitor using the video cable. The router's main interface will be
displayed on the monitor.
Step 3 Turn on the switch of the bluetooth mouse to enable the bluetooth enable.
Step 4 Use the wired mouse to choose Settings > Bluetooth > Scan and find the bluetooth mouse in
the list of available devices.
Issue 08 (2015-05-08)
34
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Step 5 Click the bluetooth mouse to match it with the router. After the match succeeds, you can
configure the router using the bluetooth mouse.
Step 6 Turn on the switch of the bluetooth keyboard and press the connect button on the keyboard to
enable the bluetooth function.
Step 7 Use the bluetooth mouse to choose Settings > Bluetooth > Scan and find the bluetooth keyboard
in the list of available devices.
Step 8 Click the bluetooth keyboard to match it with the router, type in the verification code displayed
on the screen using the bluetooth keyboard, and then press Enter. After the match succeeds, you
can configure the router using the bluetooth keyboard.
Issue 08 (2015-05-08)
35
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3 Installing AR120/AR150/AR160/AR200 Series Routers
----End
Mouse
Keyboard
Procedure
Step 1 Connect a mouse and a keyboard to the USB (Host) ports of the router.
NOTE
The AR161FW-P-M5 supports Bluetooth connections. You can connect the mouse and keyboard using
Bluetooth.
Step 2 Connect the router to the display screen through a video cable. The router main interface is
displayed on the screen.
Issue 08 (2015-05-08)
36
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
3 Installing AR120/AR150/AR160/AR200 Series Routers
Hardware Installation and Maintenance Guide
Step 3 Enter the initial password Admin@huawei and click LOGIN. You successfully log in to the
router.
Step 4 Use the mouse and keyboard to view required information and perform configurations using the
menu on the main interface.
NOTE
Step 5 Click
NOTE
Use the keyboard and mouse to view and set menus on the APPS page of the router.
l You can right-click on the main interface to return to the upper-level menu.
l You can also press ESC to return to the upper-level menu.
37
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3 Installing AR120/AR150/AR160/AR200 Series Routers
Choose Settings > PRIVACY&SECURITY > Security > USER SETTINGS > Change
password to change the login password.
NOTE
Choose Settings > PRIVACY&SECURITY > Security > USER SETTINGS > Modify
the lock screen time/s to set the screen lock timeout.
NOTE
Choose Settings > PRIVACY&SECURITY > Security. The security configuration page
is displayed. In Unknown sources, set whether to allow installation of unknown
applications to control the path where the applications are obtained.
----End
Issue 08 (2015-05-08)
38
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
39
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
DANGER
Before drilling holes on a wall, make sure there are no power cables in the wall to avoid electric
shock.
NOTICE
l Take water-proofing measures to protect a wall-mounted router from damages caused by
water.
l Screws must be installed solid in the wall; otherwise, the wall-mounted router may fall down
after cables are connected.
l Ensure that there are no flammable or explosive materials near the router and no obstructions
within 100 mm around the router.
l Install the router at an appropriate height to ensure that the indicators can be observed easily.
Measuring tape
Marker
Hammer drill
Phillips screwdriver
Procedure
Step 1 Install a SIM card into the router.
1.
Use a Phillips screwdriver to loosen the M3x6 screw on the SIM card cover, remove the
SIM card cover, and place it in an appropriate place for later use.
2.
Align the SIM card with a SIM card slot and horizontally insert the SIM card into the slot,
until you hear a click.
Issue 08 (2015-05-08)
40
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
When inserting a SIM card, keep the notch on the SIM card in the same direction as the
notch marked above the slot.
NOTE
3.
Install the SIM card cover back to the router and tighten the M3x6 screw.
M7
-L
W
3G
50
AR
Step 2 Use a measuring tape to determine the two mounting bracket installation positions. Keep the
two positions on a horizontal line and mark the positions with a marker.
l
To mount the router horizontally, make a 139 mm of center distance between the two
mounting holes.
To mount the router vertically, make a 187 mm of center distance between the two mounting
holes.
Issue 08 (2015-05-08)
41
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
.UXO`UTZGRR_
139mm
<KXZOIGRR_
187mm
Step 3 Use the Phillips screwdriver to fix the mounting brackets on both sides of the router with four
M4x8 screws.
Use the Phillips screwdriver to install two M4x8 self-tapping screws in the marked positions
on the wall, and leave 2 mm of the screws out of the wall.
2.
Hang the router on the M4x8 self-tapping screws through mounting holes on the mounting
brackets.
Issue 08 (2015-05-08)
42
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3.
Use the Phillips screwdriver to tighten the two M4x8 self-tapping screws. Then install and
tighten two M4x8 self-tapping screws in the lower mounting holes to secure the router on
the wall.
NOTE
The methods for mounting a router horizontally and vertically are the same. The preceding procedure
mounts a router horizontally.
2mm
----End
Issue 08 (2015-05-08)
43
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Context
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Console cable
NOTE
The console cable is not included in the installation accessory package and needs to be purchased separately.
Procedure
Step 1 Connect the console cable.
1.
Connect a DB9 connector of the console cable to the RS232 interface (DB9) of the router.
2.
Connect the DB9 connector at the other end of the console cable to the serial interface
(COM) of a management PC.
RS232
COM
Console cable
----End
Issue 08 (2015-05-08)
44
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Diagonal pliers
Cable ties
Marker
Procedure
Step 1 Select Ethernet cables of appropriate quantity and lengths according to the number of ports and
measured cabling distances.
Step 2 Attach temporary labels to both ends of each Ethernet cable and write numbers on the labels to
identify the Ethernet cables. For details, see 14.5.3 Engineering Labels for Network Cables.
Step 3 Connect one end of an Ethernet cable to an Ethernet interface of the router and the other end to
an Ethernet interface of the remote device.
Network cable
Ethernet interface of
the remote device
Issue 08 (2015-05-08)
45
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 4 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 5 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm away
from the connectors at both ends.
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l The two Wi-Fi strip-shaped antennas must be more than 100 mm away from each other.
Phillips screwdriver
Cable ties
Diagonal pliers
Procedure
Step 1 Connect the Wi-Fi strip-shaped antennas.
l
Method 1: Attach the Wi-Fi strip-shaped antennas to both sides of the router, and then use
a Phillips screwdriver to fix the antennas with four M2.5x8 screws.
Method 2: Attach the Wi-Fi strip-shaped antennas on a clean plane, and then use a Phillips
screwdriver to fix the antennas with four M2.5x8 screws.
Issue 08 (2015-05-08)
46
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Plane
Step 2 Connect the other end (female connector) of each Wi-Fi strip-shaped antenna to a Wi-Fi antenna
interface of the router.
NOTICE
When the router is used on a bus, insert connectors of the antennas securely to ensure that the
antennas can sustain long-time vibration when the bus is running.
Issue 08 (2015-05-08)
47
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 3 Arrange feeders of the Wi-Fi strip-shaped antennas and bundle them with cable ties. Use diagonal
pliers to cut off redundant cable ties.
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l The two LTE remote antennas must be more than 230 mm away from each other.
l Bundle the LTE remote antennas with cable ties.
LTE remote antennas for the router include a primary LTE remote antenna and a GPS+LTE
remote diversity antenna. Table 4-1 lists connections of the two LTE remote antennas.
Table 4-1 Connections of LTE remote antennas
Issue 08 (2015-05-08)
Antenna
Connect To
48
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTE
The primary LTE remote antenna and GPS+LTE remote diversity antenna are installed in the same way.
The following procedure installs the GPS+LTE remote diversity antenna.
Procedure
Step 1 Connect the SMA connectors of the GPS+LTE remote diversity antenna to the GPS interface
and LTE DIV interface of the router, and attach the other end (cover) to a plastic plane.
NOTICE
l When the router is used on a bus, insert connectors of the antennas securely to ensure that
the antennas can sustain long-time vibration when the bus is running.
l You can use an electric drill to fix the cover on the horizontal plane with two M3.5 selftapping screws.
----End
Issue 08 (2015-05-08)
49
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Context
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on the router before you finish connecting cables.
l Keep signal cables more than 10 cm away from power cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
The power cable parameters vary in different countries or regions. The figures in this section are for
reference only.
Wire Color
2-pin Male
Connector
2-pin Female
Connector
1-black (-)
Black
Green
Red
4-white (+)
White
Issue 08 (2015-05-08)
50
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Blade fuse
ACC
Bus key
Battery
ON
AR503GW-LM7
Off
Master power
switch
Ground wire
Powered devices
NEG-
Power cable
Procedure
Step 1 Connect the M12 connector to the power jack on the router and select a 2-pin connector at the
other end to connect a 2-pin power terminal on the external power supply system based on the
power terminal type.
NOTICE
When the router is used on a bus, insert the connectors of the power cable securely to ensure
that the power cable can sustain long-time vibration when the bus is running.
Issue 08 (2015-05-08)
51
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
----End
Procedure
Turn on the power switch of the external power supply system to start the router.
After the router starts, check indicators on the front panel to check whether the router runs
normally. Figure 4-2 describes the indicator states when the router is running normally.
Issue 08 (2015-05-08)
52
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
M7
-L
W
3G
50
AR
Indicator
Description
PWR
SYS
NOTICE
Powering off the router will interrupt all the services on the router. Exercise caution when
you perform this operation.
Turn off the power switch of the external power supply system.
----End
Issue 08 (2015-05-08)
53
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
54
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
l Ensure that the desk is flat and properly grounded.
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Do not place other objects on the router.
Procedure
Step 1 Attach four rubber pads in the imprinted round areas marked plus (+) signs at the bottom of the
router.
Issue 08 (2015-05-08)
55
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
-L-D-H
AR509G
VDSL
CON RS23
----End
DANGER
Before drilling holes on a wall, make sure there are no power cables in the wall to avoid electric
shock.
NOTICE
l Take water-proofing measures to protect a wall-mounted router from damages caused by
water.
l Screws must be installed solid in the wall; otherwise, the wall-mounted router may fall down
after cables are connected.
l Ensure that there are no flammable or explosive materials near the router and no obstructions
within 100 mm around the router.
l Install the router at an appropriate height to ensure that the indicators can be observed easily.
Measuring tape
Marker
Hammer drill
Phillips screwdriver
Issue 08 (2015-05-08)
56
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Install a SIM card into the router.
1.
Use a Phillips screwdriver to loosen the captive screw on the SIM card cover, remove the
SIM card cover, and place it in an appropriate place for later use.
2.
Align the SIM card with a SIM card slot and horizontally insert the SIM card into the slot,
until you hear a click.
NOTICE
When inserting a SIM card, keep the notch on the SIM card in the same direction as the
notch marked above the slot.
NOTE
3.
Install the SIM card cover back to the router and tighten the captive screw.
a
AR509G
-L-D-H
VDSL
232
CON RS
Step 2 Use a measuring tape to determine the two mounting bracket installation positions. Keep the
two positions on a horizontal line and mark the positions with a marker.
l
To mount the router horizontally, make a 150 mm of center distance between the two
mounting holes.
To mount the router vertically, make a 210 mm of center distance between the two mounting
holes.
Issue 08 (2015-05-08)
57
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
ZOTM
RSU[T
G
Z
T
U
`
O
.UX
150mm
[TZOTM
RSU
<KX ZOIG
210mm
Step 3 Use the Phillips screwdriver to fix the mounting brackets on both sides of the router with four
M4x8 screws.
-L-D-H
AR509G
VDSL
CON RS
232
Issue 08 (2015-05-08)
Use the Phillips screwdriver to install two M4x8 self-tapping screws in the marked positions
on the wall, and leave 2 mm of the screws out of the wall.
58
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
2.
Hang the router on the M4x8 self-tapping screws through mounting holes on the mounting
brackets.
3.
Use the Phillips screwdriver to tighten the two M4x8 self-tapping screws. Then install and
tighten two M4x8 self-tapping screws in the lower mounting holes to secure the router on
the wall.
2mm
----End
Issue 08 (2015-05-08)
59
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
AR509G
-L-D-H
VDSL
CON RS
232
AP
AP
NOTE
On an AR509G-L-D-H router, LAN interfaces GE0 to GE3 support the PoE function.
The PoE power supply is not included in the installation accessory package and needs to be purchased
separately.
Procedure
Step 1 Connect one end of the PoE power supply to the PoE power jack of the router and the other end
to an AC power outlet.
Issue 08 (2015-05-08)
60
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
AR509G
-L-D-H
VDSL
CON RS
232
AP
AP
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l When connecting cables, notice interface identifiers to ensure correct cable connections.
Incorrect cable connections may cause damage to the interface module or the router.
The console cable is not included in the installation accessory package and needs to be purchased separately.
Procedure
Step 1 Connect the console cable.
1.
Connect the RJ45 connector of the console cable to the console interface (RJ45) of the
router.
2.
Connect the DB9 connector of the console cable to the serial interface (COM) of a
management PC.
Issue 08 (2015-05-08)
61
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
CON RS232
AR509G-L-D-H
CON RS232
VDSL
COM interface
Console cable
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l When connecting cables, notice interface identifiers to ensure correct cable connections.
Incorrect cable connections may cause damage to the interface module or the router.
Diagonal pliers
Marker
Issue 08 (2015-05-08)
62
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Select Ethernet cables of appropriate quantity and lengths according to the number of interfaces
and measured cabling distances.
Step 2 Attach temporary labels to both ends of each Ethernet cable and write numbers on the labels to
identify the Ethernet cables. For details, see 14.5.3 Engineering Labels for Network Cables.
Step 3 Connect one end of an Ethernet cable to an Ethernet interface of the router and the other end to
an Ethernet interface of the remote device.
GE0
GE1
GE2
GE3
AR509G-L-D-H
CON RS232
VDSL
Ethernet Cables
Ethernet interface of
the remote device
Step 4 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 5 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm away
from the connectors at both ends.
----End
Follow-up Procedure
Check the following items after connecting Ethernet cables:
l
Labels are correctly filled and securely attached to cables, with texts facing the same
direction.
Issue 08 (2015-05-08)
63
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
l The ground cable of a router must be correctly connected to protect the router against
lightning and interference.
l Do not power on the router before you finish connecting cables.
Phillips screwdriver
Multimeter
Ground cable
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Connect the ground cable.
1.
Use a Phillips screwdriver to remove the M4 screw from the ground point on the interface
panel of the router. Keep the M4 screw in an appropriate place for later use.
2.
Align the M4 lug of the ground cable with the tapped hole on the ground point, and then
secure the ground cable with the M4 screw.
3.
Connect the M6 lug of the ground cable to a ground point on the wall or DIN rail, and
secure the M6 lug with an M6 screw.
Issue 08 (2015-05-08)
64
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
AR509G-L-D-H
CON RS232
VDSL
Ground cable
12V;1A
12V;1A
----End
Follow-up Procedure
Perform the following operations after connecting the ground cable:
l
Check that the ground cable is securely connected to the ground points.
Use a multimeter to measure the resistance between the ground points at two ends of the
ground cable. The resistance must be smaller than 5 ohm.
NOTICE
l Do not power on the router before you finish connecting cables.
l When connecting cables, notice interface identifiers to ensure correct cable connections.
Incorrect cable connections may cause damage to the interface module or the router.
Procedure
Step 1 Connect one end of a standard telephone cable to the VDSL interface of the router and the other
end to an DSL device.
Issue 08 (2015-05-08)
65
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
VDSL
AR509G-L-D-H
CON RS232
VDSL
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Procedure
Step 1 Connect the LTE whip antennas to the SMA connectors on the rear panel of the router.
Issue 08 (2015-05-08)
66
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
4G
AR509G-L
-D-H
4G
4G
VDSL
CON RS2
32
Step 2 Adjust positions of the antennas to obtain the optimal wireless transmission and receiving
performance.
If the router is placed on a desk, make the primary antenna vertical to the desk and the
secondary antenna parallel to the desk.
-
AR509G-L
-D-H
-
3G
VDSL
CON RS2
Issue 08 (2015-05-08)
32
If the router is mounted on a wall, make the primary antenna parallel to the wall and the
secondary antenna vertical to the wall.
67
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
-
-
----End
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
Do not power on the router before you finish connecting the power cables.
Issue 08 (2015-05-08)
68
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Power cable
Procedure
Step 1 Verify that the router is reliably grounded.
Step 2 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 3 Connect power cables.
1.
Connect one end of the power cable to the power jack on the router.
2.
Connect the other end of the power cable to the DC power source.
1
AR509G-L-D-H
CON RS232
VDSL
DC power source
----End
Follow-up Procedure
Perform the following operations after connecting the power cable:
l
If multiple routers are installed, attach labels to both ends of each power cable and write
numbers on the labels to identify them.
69
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Context
Check the following items before powering on the router:
l
Procedure
Turn on the power switch of the external power supply system to start the router.
After the router starts, check indicators on the router to check whether the router runs
normally. Figure 5-2 describes the indicator states when the router is running normally.
Figure 5-2 Normal indicator states on the router
AR509G
-L-D-H
VDSL
232
CON RS
Indicator
Description
PWR
SYS
NOTICE
Powering off the router will interrupt all the services on the router. Exercise caution when
deciding to perform this operation.
Issue 08 (2015-05-08)
70
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Turn off the power switch of the external power supply system.
----End
Follow-up Procedure
After the router starts, you can log in to its CLI to configure, manage, and maintain the router.
For details, see the CLI-based Configuration.
Issue 08 (2015-05-08)
71
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
72
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
NOTICE
l Ensure that the desk is flat and properly grounded.
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Do not place other objects on the router.
Phillips screwdriver
Procedure
Step 1 Install SIM cards into the router.
1.
Use a Phillips screwdriver to loosen the M3 screw on the SIM card cover, and remove the
SIM card cover from the router. Keep the SIM card cover and M3 screw in an appropriate
place for later use.
2.
Align the SIM card with a SIM card slot and horizontally insert the SIM card into the slot,
until you hear a click.
NOTICE
When inserting the SIM card, keep the notch on the SIM card in the same direction as the
notch marked on the left of the slot.
NOTE
3.
Issue 08 (2015-05-08)
Install the SIM card cover back to the router and tighten the M3 screw.
73
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
SIM2
micro SD
IV
E-D
SIM1
3G/LT
GP
micro SD
micro SD
micro SD
1
3G/LT
IV
E-D
GP
IV
E-D
3G/LT
GP
1
2
SIM1
SIM2
micro SD
PWR S
SY
USB AN
WW SI
RS
MODES
GP AN1
WL AN2
WL
FI0
FI1
IV
E-D
MAIN
E-
3G/LT
3G/LT
GP
WI
WI
GE0
GE1
RESET
CONSOLE
micro SD
OTG
SIM1
SIM2
micro SD
PWR
SYS
USB AN
WW I
RSS DE
MO
GPS N1
WLA N2
WLA
FI0
WI
GE1
GE0
IV
E-D
AIN
E-M
GP
3G/LT
FI1
WI
3G/LT
CONSOL
RESET
micro SD
OTG
SIM1
SIM2
micro SD
----End
DANGER
Before drilling holes on a wall, make sure that no power cable is routed in the wall. Otherwise,
power cables in the wall may cause personal injury.
Issue 08 (2015-05-08)
74
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
NOTICE
l Take water-proofing measures to protect a wall-mounted router from damages caused by
water.
l Screws must be installed solid in the wall; otherwise, the wall-mounted router may fall down
after cables are connected.
l Ensure that there are no flammable or explosive materials near the router and no obstructions
within 100 mm around the router.
l Install the router at an appropriate height to ensure that the indicators can be observed easily.
Marker
Hammer drill
Electric drill
Wrench
Phillips screwdriver
Mounting bracket
The mounting bracket is not included in the installation accessory package and needs to be purchased
separately.
Procedure
Step 1 Install SIM cards into the router.
1.
Use a Phillips screwdriver to loosen the M3 screw on the SIM card cover, and remove the
SIM card cover from the router. Keep the SIM card cover and M3 screw in an appropriate
place for later use.
2.
Align the SIM card with a SIM card slot and horizontally insert the SIM card into the slot,
until you hear a click.
NOTICE
When inserting the SIM card, keep the notch on the SIM card in the same direction as the
notch marked on the left of the slot.
NOTE
Issue 08 (2015-05-08)
75
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
3.
Install the SIM card cover back to the router and tighten the M3 screw.
SIM2
micro SD
IV
E-D
S
SIM1
3G/LT
GP
micro SD
micro SD
micro SD
1
IV
E-D
3G/LT
GP
IV
E-D
3G/LT
GP
1
2
SIM1
SIM2
micro SD
PWR S
SY
USB AN
WW SI
RS
MODES
GP AN1
WL AN
WL
WI
FI0
GE0
WI
FI1
IV
E-D
GP
GE1
MAIN
E-
3G/LT
3G/LT
RESET
CONSOLE
micro SD
OTG
SIM1
SIM2
micro SD
Step 2 Attach the mounting bracket to the wall and keep its top and bottom edges horizontal. Use a
marker to mark four mounting positions, two at the top and two at the bottom.
Attach the mounting bracket to the rear of the router and align the four mounting holes on
the mounting bracket with the tapped holes on the router.
2.
Issue 08 (2015-05-08)
76
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
RESET
I0
WIF
CONSOLE
GE1
GE0
I1
WIF
SIM1
SIM2
OTG
S
GP
micro SD
MAIN
TE-
DIV
TE-
Use an appropriate method to mount the router according to conditions of the wall surface. Two typical
wall mounting methods are provided here.
Method 1: Use tapping screws to mount the router on the wall. You do not need to drill
holes on the wall.
Hold the router with the heat warning label upright. Align the four mounting holes on the
mounting bracket with the four mounting positions marked on the wall in step 1, and use
four M4 tapping screws to fix the router on the wall.
Issue 08 (2015-05-08)
77
OTG
SIM1
SIM2
micro SD
CONSOLE
RESET
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
Method 2: Use bolts to mount the router on the wall. You need to drill holes on the wall.
1.
Use a hammer drill to drill holes in the four mounting positions marked on the wall
in step 1.
2.
Hold the router with the heat warning label upright, and use four M4 bolts to fix the
router on the wall.
78
OTG
SIM1
SIM2
micro SD
CONSOLE
RESET
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
----End
Issue 08 (2015-05-08)
79
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Context
NOTICE
l You are advised to install the router on the floor in a bus.
l You are advised to install the router behind the driver seat, because this position is close to
the dashboard and makes it easy for the router to connect to the power source and other
devices in the bus.
l The router installation position should not hinder open and closing of cabinet doors or the
inspection hatch, and should not affect maintenance of other devices in the bus.
l Screws on the router must be tightened solid to ensure that the router can sustain long-time
vibration when the bus is running.
l Sufficient clearance must be reserved around the router for later cable connection and router
maintenance.
Phillips screwdriver
Electric drill
Mounting bracket
Router support
l The mounting bracket and router support are not included in the installation accessory package and
needs to be purchased separately.
l To protect the router from theft, use one or two M4 hex socket screws among the screws mentioned in
steps 2, 3, and 5.
The router support consists of a base and two top covers, as shown in Figure 6-1.
Issue 08 (2015-05-08)
80
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Top cover
Support base
Procedure
Step 1 Install SIM cards into the router.
1.
Use a Phillips screwdriver to loosen the M3 screw on the SIM card cover, and remove the
SIM card cover from the router. Keep the SIM card cover and M3 screw in an appropriate
place for later use.
2.
Align the SIM card with a SIM card slot and horizontally insert the SIM card into the slot,
until you hear a click.
NOTICE
When inserting the SIM card, keep the notch on the SIM card in the same direction as the
notch marked on the left of the slot.
NOTE
3.
Issue 08 (2015-05-08)
Install the SIM card cover back to the router and tighten the M3 screw.
81
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
SIM2
micro SD
micro SD
3G/LT
GP
IV
E-D
SIM1
micro SD
micro SD
1
3G/LT
IV
E-D
GP
IV
E-D
3G/LT
GP
SIM1
SIM2
micro SD
PWR S
SY
USB AN
WW SI
RS
MODES
GP AN1
WL AN2
WL
FI0
WI
WI
FI1
GE0
IV
E-D
MAIN
E-
3G/LT
3G/LT
GP
GE1
RESET
CONSOLE
micro SD
OTG
SIM1
SIM2
micro SD
Attach the mounting bracket to the rear of the router and align the four mounting holes on
the mounting bracket with the tapped holes on the router.
2.
RESET
I0
WIF
CONSOLE
GE1
GE0
I1
WIF
OTG
S
GP
SIM1
SIM2
DIV
TE-
micro SD
MAIN
TE-
Keep the power supply side of the router at the same side with the cable notches on the
support base. Place the router inside of the four positioning plates.
2.
Align the four mounting holes on the mounting bracket with the four tapped holes on the
support base, use four M4 screws to fix the router on the support base, and tighten the M4
screws with a Phillips screwdriver.
Issue 08 (2015-05-08)
82
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
AR
51
0 Se
rie
PWR
SYS
USB
WWAN
RSSI
MODE
GPS
WAN1
WAN2
Output0
VIDEO
Output1
VIDEO
ut
Input/Outp
AUDIO
8-36 V;
4A
Step 4 Place the router support in the planned position and use four M4 tapping screws to fix it on the
bus floor.
NOTICE
Before performing this step, connect cables to the router by referring to 6.5 Connecting the
Router.
NOTE
l It is recommended that power supply side (cable side) of the router should face the left to protect cables
from collisions with passengers.
l It is recommended that you connect a USB data extension cable to the USB interface to facilitate future
maintenance operations on the router.
PWR
PWR
SYS
SYS
USB
USB
N
WWAN
WWA
RSSI
RSSI
E
MODE
MOD
GPS
GPS
WLAN11 22
WLAN
WLAN
WLAN
GE0
WI
FI0
GE1
WI
FI2
3G/LT
E-DIV
AIN
E-M
3G/LT
GP
RESET
CONSOLE
micro SD
OTG
SIM1
SIM2
micro SD
2.
Issue 08 (2015-05-08)
83
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Top cover
PWR
SYS
USB
WWAN
RSSI E
MOD
GPS
WLAN1 2
WLAN
Top cover
WI
FI0
GE0
WI
3G/LT
E-DIV
AIN
E-M
3G/LT
GP
FI2
RESET
CONSOLE
micro SD
0
OTG
SIM0
SIM1
micro SD
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l The two LTE remote antennas must be more than 230mm away from each other.
l Bundle the LTE remote antennas with cable ties.
LTE remote antennas for the router include a primary LTE remote antenna and a GPS+LTE
remote diversity antenna. Table 6-1 lists connections of the two LTE remote antennas.
Table 6-1 Connections of LTE remote antennas
Issue 08 (2015-05-08)
Antenna
Connect To
84
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
NOTE
The primary LTE remote antenna and GPS+LTE remote diversity antenna are installed in the same way.
The following procedure installs GPS+LTE remote diversity antenna.
Procedure
Step 1 Connect the SMA connectors of the GPS+LTE remote diversity antenna to the GPS interface
and LTE DIV interface of the router, and attach the other end (cover) to a plastic horizontal
plane.
NOTICE
l Insert connectors of the LTE remote antennas securely to ensure that the antennas can sustain
long-time vibration when the bus is running.
l You can use an electric drill to fix the cover on the horizontal plane with two M3.5 tapping
screws.
3G/LT
DIV
E-
PS
SIM2
GE1
GE0
WI
WI
0
FI
SIM1
AIN
-M
DIV
E-
PS
1
OTG
3G/LTE
1
FI
3G/LT
micro SD
CONSOLE
RESET
micro SD
----End
85
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Context
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l The two Wi-Fi button remote antennas must be more than 100 mm away from each other.
l Bundle the Wi-Fi button remote antennas with cable ties.
NOTE
l A Wi-Fi button remote antenna consists of a Wi-Fi button antenna and a Wi-Fi feeder.
l Wi-Fi button remote antennas must be installed on an insulated surface. If they are installed on a metal
surface, Wi-Fi coverage in the bus will be severely affected.
l It is recommended that Wi-Fi button remote antennas be installed on ceiling of the bus.
Marker
3 m Wi-Fi feeders
Plastic screws
Procedure
Step 1 Connect the female connector of a Wi-Fi feeder to a Wi-Fi antenna interface, and connect the
male connector to a Wi-Fi button antenna.
NOTICE
Insert connectors of the Wi-Fi feeders securely to ensure that the antennas can sustain long-time
vibration when the bus is running.
Issue 08 (2015-05-08)
86
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
WI
SIM2
GE1
GE0
micro SD
micro SD
WI
WI
CONSOLE
0
FI
SIM1
AIN
-M
DIV
E-
PS
1
OTG
3G/LTE
1
FI
3G/LT
0
FI
1
FI
WI
RESET
Step 2 Use a marker to mark the mounting holes for the two Wi-Fi button antennas on the ceiling.
NOTE
If the distance from a Wi-Fi button antenna to the router exceeds 3 m, use a Wi-Fi extension cable to
lengthen the Wi-Fi button remote antenna.
Step 3 Use plastic screws to fix the Wi-Fi button antennas on the ceiling.
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
The MicroUSB data cable is not included in the installation accessory package and needs to be purchased
separately.
Issue 08 (2015-05-08)
87
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Connect the MicroUSB data cable.
1.
Connect the MicroUSB end of the MicroUSB data cable to the MicroUSB port of the router.
2.
Connect the USB end of the MicroUSB data cable to a USB port of the management PC.
CONSOLE
SIM2
GE1
GE0
WI
WI
micro SD
CONSOLE
0
FI
SIM1
AIN
-M
DIV
E-
PS
1
OTG
3G/LTE
1
FI
3G/LT
USB
RESET
micro SD
Before using the console interface to log in to the device, install the console port driver on the PC.
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Diagonal pliers
Cable ties
Marker
Issue 08 (2015-05-08)
88
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Select Ethernet cables of appropriate quantity and lengths according to the number of ports and
measured cabling distances.
Step 2 Attach temporary labels to both ends of each Ethernet cable and write numbers on the labels to
identify the Ethernet cables. For details, see 14.5.3 Engineering Labels for Network Cables.
Step 3 Connect one end of an Ethernet cable to an Ethernet interface of the router and the other end to
an Ethernet interface of the remote device.
GE0
SIM2
GE1
GE0
WI
WI
micro SD
CONSOLE
0
FI
SIM1
AIN
-M
DIV
E-
PS
1
OTG
3G/LTE
1
FI
3G/LT
RESET
micro SD
Network cable
Ethernet interface of
the remote device
Step 4 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 5 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm away
from the connectors at both ends.
----End
The AR511GW-LAV2M3 and AR511GW-L-B3 routers can connect to audio terminals using audio cables.
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l Keep signal cables more than 10 cm away from power cables.
l Cables routed out from the router support must have O-rings installed to protect them from
water.
Issue 08 (2015-05-08)
89
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Signal
Wire Color
Connect To
DB9
Audio interface
Bare wire
IN
Red
Station reporter
IN-GND
White
OUT-L
Blue
OUT-L-GND
Green
OUT-R
Yellow
OUT-R-GND
Black.
Stereo (right
channel)
Diagonal pliers
Audio cable
Procedure
Step 1 Use a pair of diagonal pliers to peel 10 mm of insulation coating off the six bare wires of the
audio cable.
NOTICE
Do not cut the metal conductor of the bare wires when peeling insulation coating.
Step 2 Connect the DB9 connector of the audio cable to the audio interface of the router, and connect
the other end with bare wires to the station reporter and stereo.
NOTICE
Insert the connector of the audio cable securely to ensure that the cable can sustain long-time
vibration when the bus is running.
Issue 08 (2015-05-08)
90
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
AUDIO Input/Output
Station reporter
AUDIO Input/Output
2
VIDEO Output1
VIDEO Output0
8-36 V; 4 A
IN
IN-GND
Audio cable
OUT-L
OUT-L-GND
Stereo (right channel)
OUT-R
OUT-R-GND
----End
The AR511GW-LAV2M3 and AR511GW-L-B3 routers can connect to video terminals using video cables.
NOTICE
l Do not power on the router before you finish connecting cables.
l Before connecting a router to a video terminal using a video cable, power on the router and
video terminal to verify that they can work normally. Then power off the router and video
terminal, and connect the video cable.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l Keep signal cables more than 10 cm away from power cables.
l Cables routed out from the router support must have O-rings installed to protect them from
water.
Issue 08 (2015-05-08)
91
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Diagonal pliers
Video cable
Procedure
Step 1 Connect the DVI-I connector of a video cable to a video interface of the router and the BNC
connector to a video terminal, such as a TV set or a monitor.
NOTE
If only one video cable is required, connect the video cable to interface VIDEO Output0 of the router (the
one on the right).
NOTICE
Insert connectors of the video cable securely to ensure that the cable can sustain long-time
vibration when the bus is running.
VIDEO Output0
AUDIO Input/Output
2
VIDEO Output1
VIDEO Output0
8-36 V; 4 A
Video cable
----End
Issue 08 (2015-05-08)
92
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Context
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on the router before you finish connecting cables.
l Keep signal cables more than 10 cm away from power cables.
l Cables routed out from the router support must have O-rings installed to protect them from
water.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
The power cable parameters vary in different countries or regions. The figures in this section are for
reference only and may differ from the cables delivered.
Wire Color
NEG (-)
Black
ACC-NEG (-)
Green
ACC-RTN (+)
Red
RTN (+)
White
A router supports two power inputs, one from a power source on the bus (constant power supply),
and the other from the ACC circuit on the bus (switch controlled power supply). Figure 6-2
shows how the power cable is connected.
Issue 08 (2015-05-08)
93
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Blade fuse
ACC
Bus key
ON
Ground wire
ACC-NEG-
AR511GW-LAV2M3
Off
Master power
switch
Battery
ACC-RTN+
Blade fuse
Powered devices
NEG-
Diagonal pliers
Power cable
O-rings (optional)
Procedure
Step 1 Use a pair of diagonal pliers to peel 10 mm of insulation coating off the four bare wires of the
power cable.
NOTICE
Do not cut the metal conductor of the bare wires when peeling insulation coating.
Step 2 Connect the M12 connector of the power cable to the power jack of the router, and connect the
bare wires at the other end to the constant power supply and switch controlled power supply on
the bus.
NOTICE
l Insert the connector of the power cable securely to ensure that the power cable can sustain
long-time vibration when the bus is running.
l When the router is installed on a bus, ensure that the four bare wires of the power cable are
securely connected to power sources on the bus. It is recommended that you weld the bare
wires on the power terminals on the bus.
Issue 08 (2015-05-08)
94
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
8-36 V; 4 A
AUDIO Input/Output
2
VIDEO Output1
VIDEO Output0
8-36 V; 4 A
Power cable
ACC-RTN+
ACC-NEG- Switch controlled power supply
RTN+
NEG-
----End
Procedure
Turn on the power switch of the external power supply system to start the router.
After the router starts, check indicators on the front panel to check whether the router runs
normally. Figure 6-3 describes the indicator states when the router is running normally.
Issue 08 (2015-05-08)
95
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
PWR S
SY
USB AN
WW SI
RS
MODES
GP AN1
WL AN2
WL
WI
FI0
GE0
WI
FI1
3G/LT
IV
E-D
GP
GE1
MAIN
E-
3G/LT
RESET
CONSOLE
micro SD
OTG
SIM1
SIM2
micro SD
Indicator
Description
PWR
SYS
NOTICE
Powering off the router will interrupt all the services on the router. Exercise caution when
you perform this operation.
Turn off the power switch of the external power supply system.
----End
The AR511GW-LAV2M3 and AR511GW-L-B3 routers integrate an Android operating system. You can
log in the routers and configure them using the Android operating system.
Issue 08 (2015-05-08)
96
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
Mouse
Keyboard
USB hub
Procedure
Step 1 Connect a mouse and a keyboard to the USB (Host) interface of the router.
NOTE
The router has only one USB (Host) interface. Connect a USB hub to this USB interface to provide more
USB interfaces.
Step 2 Connect the router to a monitor using the video cable. The router's main interface will be
displayed on the monitor.
Step 3 Enter the default password Admin@huawei to display the main interface of the router.
Step 4 Click
Issue 08 (2015-05-08)
97
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
NOTE
Use the keyboard and mouse to view and set menus on the APPS page of the router.
l You can right-click on the main interface to return to the upper-level menu.
l You can also press ESC to return to the upper-level menu.
Choose Settings > PRIVACY&SECURITY > Security > USER SETTINGS > Change
password to change the login password.
NOTE
Choose Settings > PRIVACY&SECURITY > Security > USER SETTINGS > Modify
the lock screen time/s to set the screen lock timeout.
NOTE
Issue 08 (2015-05-08)
Choose Settings > PRIVACY&SECURITY > Security. The security configuration page
is displayed. In Unknown sources, set whether to allow installation of unknown
applications to control the path where the applications are obtained.
98
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
6 Installing AR511GW-LAV2M3/AR511GW-L-B3 Routers
Hardware Installation and Maintenance Guide
----End
Issue 08 (2015-05-08)
99
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
100
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
l A SIM card is not hot swappable.
l Industrial SIM cards are recommended for the AR routers.
l If only one SIM card needs to be installed, install it in slot SIM1 (the top slot).
l When inserting a SIM card, keep the notch on the SIM card in the same direction as the notch
marked on the left of the slot.
Phillips screwdriver
Procedure
Step 1 Use a Phillips screwdriver to loosen the three captive screws on the metal box and remove the
top cover from the box. Keep the top cover in an appropriate place for later use.
a
Step 2 Install a SIM card into the router.
1.
Use the Phillips screwdriver to loosen the M3 screw on the SIM card cover, and remove
the SIM card cover from the router. Keep the SIM card cover and M3 screw in an
appropriate place for later use.
2.
Align the SIM card with a SIM card slot and horizontally insert the SIM card into the slot,
until you hear a click.
3.
Install the SIM card cover back to the router and tighten the M3 screw.
Issue 08 (2015-05-08)
101
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
SIM2
micro SD
G/LTE-D
G/LTE-D
SIM1
micro SD
1
IV
3G/LT
AIN
E-M
IV
3G/LT
AIN
E-M
AIN
E-M
G/LTE-D
3G/LT
IV
micro SD
micro SD
SIM1
FI0
WI
FI1
WI
GE0
micro SD
SIM2
GPS
/LTE-DIV
AIN
E-M
3G/LT
SIM1
3G
SIM2
CONSOL
RESET
SATA
micro SD
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l The two LTE remote antennas must be more than 230 mm away from each other.
LTE remote antennas for the router include a primary LTE remote antenna and a GPS+LTE
remote diversity antenna. Table 7-1 lists connections of the two LTE remote antennas.
Table 7-1 Connections of LTE remote antennas
Antenna
Connect To
NOTE
The primary LTE remote antenna and GPS+LTE remote diversity antenna are installed in the same way.
The following procedure installs the GPS+LTE remote diversity antenna.
Issue 08 (2015-05-08)
102
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Connect the SMA male connectors of the GPS+LTE remote diversity antenna to the GPS and
LTE DIV interfaces of the router, and screw the SMA male connectors clockwise to tighten
them. Attach the cover at the other end to a horizontal plane.
NOTICE
l Insert connectors of the antennas securely to ensure that the antennas can sustain long-time
vibration when the bus is running.
PS
/LTE-D
3G
IV
/LTE-D
3G
GE0
WI
SIM0
OTG
SIM1
micro SD
SATA
WI
CONSOLE
0
FI
3G/LTE
IV
1
FI
PS
AIN
-M
l You can use an electric drill to fix the cover on the horizontal plane with two M3.5 tapping
screws.
RESET
Step 2 Put the feeders of the LTE remote antenna through the groove on the metal box, install the top
cover removed in step 1 to the metal box, and then tighten the three captive screws.
Issue 08 (2015-05-08)
103
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
----End
NOTICE
l Ensure that the desk is flat and properly grounded.
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Do not place other objects on the router.
Procedure
Step 1 Gently place the router on the desk.
Issue 08 (2015-05-08)
104
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 2 Attach the cover of the LTE remote antenna on the desk.
----End
NOTICE
l You are advised to install the router behind the driver seat, because this position is close to
the dashboard and makes it easy for the router to connect to the power source and other
devices in the bus.
l The router installation position should not hinder open and closing of cabinet doors or the
inspection hatch, and should not affect maintenance of other devices in the bus.
l Screws on the router must be tightened solid to ensure that the router can sustain long-time
vibration when the bus is running.
l Sufficient clearance must be reserved around the router for later cable connection and router
maintenance.
Phillips screwdriver
Issue 08 (2015-05-08)
105
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Use a Phillips screwdriver to secure the mSATA hard disk onto the metal fixture with two
M2.5x4 screws.
Step 2 Loosen the two M3 screws at the bottom of the metal box and remove the bottom cover from
the box.
Step 3 Insert the mSATA hard disk into the Mini PCIe slot of the router, and then secure the metal
fixture with two M2.5x4 screws.
a
b
Issue 08 (2015-05-08)
106
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 4 Install the bottom cover back to the metal box and tighten the two M3 screws.
Step 5 Align mounting holes on the mounting brackets with mounting holes on the bottom of the metal
box, and use four M4x8 screws to fix the mounting brackets on the metal box.
Step 6 Use four M4x12 screws to fix the router in the equipment box in the bus.
Step 7 Attach the cover of the LTE remote antenna to a plastic horizontal plane.
Issue 08 (2015-05-08)
107
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
It is recommended that you fix the cover with two M3.5 tapping screws using a Phillips
screwdriver, so that the cover can sustain long-time vibration when the bus is running.
----End
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on the router before you finish connecting cables.
l Keep signal cables more than 10 cm away from power cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
The power cable parameters vary in different countries or regions. The figures in this section are for
reference only.
Issue 08 (2015-05-08)
Connector P1
(M12)
Wire Color
2-pin male
connector
2-pin female
connector
1-black (-)
Black
Green
Red
4-white (+)
White
108
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
The router supports two power inputs, one from a power source on the bus (constant power
supply), and the other from the ACC circuit on the bus (switch controlled power supply). Figure
7-1 shows how the power cable is connected.
Figure 7-1 Power cable connection
RTN+
GPS
ALARM
Blade fuse
ACC
Bus key
ON
Ground wire
AR511GW-LM7
Off
Master power
switch
Battery
ACC-RTN+
Blade fuse
ACC-NEG-
Powered devices
NEG-
Power cables
Procedure
Step 1 Connect the M12 connector of the power cable to the power jack of the router, and select an
appropriate 2-pin connector at the other end to connect to the vehicle-mounted power source
based on the connector type of the vehicle-mounted power source.
NOTICE
Insert the connectors of the power cable securely to ensure that the power cable can sustain longtime vibration when the bus is running.
Issue 08 (2015-05-08)
109
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
8-36 V; 4 A
Power cable
2-pin male connector
----End
Procedure
Turn on the power switch of the external power supply system to start the router.
After the router starts, check indicators on the front panel to check whether the router runs
normally. Figure 7-2 describes the indicator states when the router is running normally.
Issue 08 (2015-05-08)
110
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Indicator
Description
PWR
SYS
NOTICE
Powering off the router will interrupt all the services on the router. Exercise caution when
you perform this operation.
Turn off the power switch of the external power supply system.
----End
Issue 08 (2015-05-08)
111
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Issue 08 (2015-05-08)
112
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Phillips screwdriver
Procedure
Step 1 Identify the three pre-defined installation areas for the router, 60 W open frame power supply,
and power adapter plate in the advertising cabinet.
Router
Step 2 Use a Phillips screwdriver to fix the mounting brackets to both sides of the router with eight M4
countersunk screws.
NOTE
Determine the depth of the router in the cabinet by fixing screws in appropriate mounting holes on the
mounting brackets. The minimum depth of the router allowed in the cabinet is 45 mm.
Issue 08 (2015-05-08)
113
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
GE1
RS485
RESET
GE0
USB0
AUDIO
Output
USB
(OTG)
CONSOL
There are two positioning pins and four studs in the router installation area, which are used to secure the
router.
1.
Hold the router with the heat warning label upright, and hang the router on the two
positioning pins in the router installation area through the two cucurbit holes on the upper
mounting bracket.
2.
Use four M4 pan head screws to fix the router on the four studs in the router installation
area.
Issue 08 (2015-05-08)
114
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
positioning pin
positioning pin
CONSOLE
RS485
USB0
AUDIO
Output
USB
(OTG)
RESET
GE1
GE0
Step 4 Install the 60 W open frame power supply horizontally in the advertising cabinet.
NOTE
Install the 60 W open frame power supply with the output side (to be connected to the power adapter plate)
facing left and the input side (to be connected to the power strip in the cabinet) facing right.
1.
Align the four mounting holes on the 60 W open frame power supply with the four studs
in the power supply installation area.
2.
Use four M3 pan head screws to fix the 60 W open frame power supply on the studs.
Issue 08 (2015-05-08)
115
CONSOLE
RS485
USB0
AUDIO
Output
p
USB
(OTG)
RESET
GE1
GE0
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
a Stud
60 W open fr
ame power su
pply
Step 5 Install the power adapter plate vertically in the advertising cabinet.
Issue 08 (2015-05-08)
116
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTE
Install the power adapter plate with the output side (to be connected to the router) facing left and the input
side (to be connected to the 60 W open frame power supply) facing right.
1.
Align the four mounting holes on the power adapter plate with the four studs in the power
adapter plate installation area.
2.
Use four M3 pan head screws to fix the power adapter plate on the studs.
Issue 08 (2015-05-08)
117
CONSOLE
RS485
USB0
AUDIO
Output
p
USB
(OTG)
RESET
GE1
GE0
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Stud
Input
Output
Issue 08 (2015-05-08)
118
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 6 Cover the 60 W open frame power supply and power adapter plate with a protection cap to
protect them from contact with the power source.
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
The MicroUSB data cable is not included in the installation accessory package and needs to be purchased
separately.
Procedure
Step 1 Connect the MicroUSB data cable.
1.
Connect the MicroUSB end of the MicroUSB data cable to the MicroUSB interface
(marked CONSOLE) of the router.
2.
Connect the USB end of the MicroUSB data cable to a USB interface of the management
PC.
Issue 08 (2015-05-08)
119
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
CONSOLE
USB
GE1
RS485
RESET
USB0
AUDIO
Output
USB
(OTG)
GE0
CONSOLE
Before logging in to the router through the console interface, install a console driver on the PC.
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Diagonal pliers
Cable ties
Marker
Procedure
Step 1 Select Ethernet cables of appropriate quantity and lengths according to the number of interfaces
and measured cabling distances.
Step 2 Attach temporary labels to both ends of each Ethernet cable and write numbers on the labels to
identify the Ethernet cables. For details, see 14.5.3 Engineering Labels for Network Cables.
Issue 08 (2015-05-08)
120
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 3 Connect one end of an Ethernet cable to an Ethernet interface of the router and the other end to
an Ethernet interface of the remote device.
GE0
GE1
RS485
RESET
USB0
AUDIO
Output
USB
(OTG)
GE0
CONSOLE
Ethernet cable
Ethernet interface of
the remote device
Step 4 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 5 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm away
from the connectors at both ends.
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l Keep signal cables more than 10 cm away from power cables.
Diagonal pliers
Cable ties
The HDMI video cable is not included in the installation accessory package and needs to be purchased
from other vendors.
Issue 08 (2015-05-08)
121
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Procedure
Step 1 Connect one end (HDMI connector) of an HDMI video cable to an HDMI video interface of the
router and the other end (HDMI connector) to a video terminal, such as an advertising screen.
NOTE
Connect the HDMI video cables to the middle or lower screen in the advertising cabinet.
HDMI0
HDMI
HDMI
WiFi1
1:5V
2:DI-0
3:GND
4:DI-1
5:DO-1
6:GND
1 2 3 4 5 6
DI/O
WiFi0
USB2
+'0,
HDMI1
eSATA
VGA
HDMI0
USB1
+'0,
Issue 08 (2015-05-08)
122
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Context
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l Keep signal cables more than 10 cm away from power cables.
Diagonal pliers
Cable ties
The VGA video cable is not included in the installation accessory package and needs to be purchased from
other vendors.
Procedure
Step 1 Connect one end (VGA connector) of an HDMI video cable to the VGA video interface of the
router and the other end (VGA connector) to a video terminal, such as an advertising screen.
NOTE
Connect VGA video cable to the upper screen in the advertising cabinet.
Issue 08 (2015-05-08)
123
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
VGA
VGA
VGA
WiFi1
1:5V
2:DI-0
3:GND
4:DI-1
5:DO-1
6:GND
1 2 3 4 5 6
DI/O
WiFi0
USB2
HDMI1
eSATA
VGA
HDMI0
USB1
Step 2 Arrange the VGA video cable to prevent it from being twisted with other cables, and then fix it
with cable ties. Use diagonal pliers to cut off redundant cable ties.
----End
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l Keep signal cables more than 10 cm away from power cables.
l An eSATA hard disk and its data cable and power cable are hot swappable.
Issue 08 (2015-05-08)
124
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Diagonal pliers
Cable ties
Procedure
Step 1 Connect the eSATA power and signal cable.
1.
Connect the eSATA connector of the eSATA power and signal cable to the eSATA interface
of the router and the 6-pin connector to the SATA hard disk power jack on the router.
2.
Connect the SAS connector of the eSATA power and signal cable to an SATA hard disk.
6Pin
WiFi1
eSATA
SAS
1:5V
2:DI-0
3:GND
4:DI-1
5:DO-1
6:GND
1 2 3 4 5 6
DI/O
3.5inch
WiFi0
USB2
HDMI1
eSATA
VGA
HDMI0
USB1
ESATA
SAS
Step 2 Arrange the eSATA power and signal cable to prevent it from being twisted with other cables,
and then fixed it with cable ties. Use diagonal pliers to cut off redundant cable ties.
----End
Issue 08 (2015-05-08)
125
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Context
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
l The two Wi-Fi button remote antennas must be more than 100 mm away from each other.
NOTE
l A Wi-Fi button remote antenna consists of a Wi-Fi button antenna and a Wi-Fi feeder.
l The Wi-Fi button remote antennas must be installed on an insulated surface. If they are installed on a
metal surface, Wi-Fi coverage will be severely affected.
Marker
Plastic screws
Cable ties
Procedure
Step 1 Connect the female connector of a Wi-Fi feeder to a Wi-Fi antenna interface on the router, and
connect the male connector to a Wi-Fi button antenna.
WiFi1
WiFi0
DI/O
WiFi0
USB2
HDMI1
eSATA
VGA
HDMI0
USB1
Step 2 Find the mounting holes for the two Wi-Fi button antennas on the top of the advertising cabinet.
NOTE
If the distance from a Wi-Fi button antenna to the router exceeds 0.65 m, use a Wi-Fi extension cable to
lengthen the Wi-Fi button remote antenna.
Step 3 Use plastic screws to fix the Wi-Fi button antennas on the top of the advertising cabinet.
----End
Issue 08 (2015-05-08)
126
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on the router before you finish connecting cables.
l Keep signal cables more than 10 cm away from power cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
l The power cable parameters vary in different countries or regions. The figures in this section are for
reference only.
l The power supply system consists of a 60 W open frame power supply and a power adapter plate.
Diagonal pliers
Phillips screwdriver
Cable ties
Procedure
Step 1 Connect the two cord end terminals of the power adapter cable to the Phoenix terminal block,
and then use a Phillips screwdriver to tighten the two screws on the top of the Phoenix terminal
block.
Step 2 Connect power cables.
1.
Connect the Phoenix terminal block on the power adapter plate cable to the power adapter
plate, and then use the Phillips screwdriver to tighten the screws at two sides of the Phoenix
terminal block. Connect the 4-pin connector of the power adapter plate cable to the power
jack of the router.
2.
Connect the 8-pin connector of the power cable of the 60 W open frame power supply to
the power adapter plate.
Issue 08 (2015-05-08)
127
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3.
Connect the 3-pin connector of the 60 W open frame power supply cable (input cable) to
the 60 W open frame power supply, and connect the C13 connector of the cable to the AC
power strip.
4Pin
WiFi1
1:5V
2:DI-0
3:GND
4:DI-1
5:DO-1
6:GND
1 2 3 4 5 6
DI/O
WiFi0
USB2
HDMI1
eSATA
VGA
HDMI0
USB1
8Pin
c
AC Power cable
AC Power strip
Step 3 Arrange the power cables to prevent them from being twisted with other cables, and then fix
them with cable ties. Use diagonal pliers to cut off redundant cable ties.
----End
128
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Procedure
Turn on the power switch of the external power supply system to start the router.
After the router starts, check indicators on the front panel to check whether the router runs
normally. Figure 8-1 describes the indicator states when the router is running normally.
Figure 8-1 Normal indicator states on the router
GE1
RS485
RESET
GE0
USB0
AUDIO
Output
USB
(OTG)
E
CONSOL
Indicator
Description
PWR
SYS
NOTICE
Powering off the router will interrupt all the services on the router. Exercise caution when
you perform this operation.
Turn off the power switch of the external power supply system.
----End
Issue 08 (2015-05-08)
129
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Installing AR2201-48FE/AR2202-48FE
Routers
Issue 08 (2015-05-08)
130
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Seen from the front panel of the router, the airflow of the router is left to right.
l If multiple routers are installed in a cabinet, it is recommended that at least 1 U of space (1
U = 44.45 mm) be kept between two routers. These routers must have the same airflow
direction; otherwise, heat dissipation is affected by hot air circulation.
Make sure the following before the installation:
l
The router installation position in the cabinet is determined and arranged properly.
The router to be installed is available and located near the cabinet for convenient movement.
Phillips screwdriver
Flat-head screwdriver
Floating nuts
Mounting brackets
M4 screws
M6 screws
Procedure
Step 1 Use a Phillips screwdriver to fix the mounting brackets to both sides of the router with M4
screws.
NOTE
The mounting brackets can be installed close to the front panel or rear panel.
Step 2 Install two floating nuts on each front mounting rail. Leave a mounting hole between the two
floating nuts on the same mounting rail.
Issue 08 (2015-05-08)
131
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTE
l The length of three adjacent mounting holes may not be 1 U. Observe the scale ticks on the mounting
rails when installing floating nuts.
l You can use a flat-head screwdriver to install floating nuts.
h4
1U
Step 3 Move the router into the cabinet. Support the bottom of the router with one hand and tighten the
M6 screws on the mounting brackets with the other hand. Tighten the lower screws first, and
then the upper screws.
----End
132
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
If the RPS150 and router are connected to the same external power supply system, the
RPS150 can prevent service interruption caused by failures of the router's internal power
module.
If the RPS150 and router are connected to different external power supply systems, the
RPS150 can prevent service interruption caused by failure of the router's internal power
module and external power supply system. Therefore, this deployment is more reliable.
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l
Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
Phillips screwdriver
Flat-head screwdriver
Floating nuts
Mounting brackets
M4 screws
M6 screws
RPS cable
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Use a Phillips screwdriver to fix the front mounting brackets at both sides of the RPS150 with
M4 screws.
Issue 08 (2015-05-08)
133
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
l The length of three adjacent mounting holes may not be 1 U. Observe the scale ticks on the mounting
rails when installing floating nuts.
l You can use a flat-head screwdriver to install floating nuts.
h4
1U
AR2202-48
FE
ON
OFF
~100-2
/60Hz;3A
40V;50
+12V; 11.5A
LINK
LINK
ACT
LINK
ACT
SA
ACT
E1
SLOT CARD
Step 4 Move the RPS150 into the cabinet. Support the bottom of the RPS150 with one hand and tighten
the M6 screws on the mounting brackets with the other hand. Tighten the lower screws first, and
then the upper screws.
Issue 08 (2015-05-08)
134
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
AR2202-48
FE
ON
OFF
~100-2
/60Hz;3A
40V;50
+12V; 11.5A
LINK
LINK
ACT
ACT
LINK
ACT
SA
E1
SLOT CARD
Put the TOP side of the RPS cable plugs upwards. Connect one end of the RPS cable to the
RPS input interface on the router, and connect the other end to the RPS output interface on
the RPS150.
2.
Tighten the captive screws at two sides of the RPS cable plugs clockwise.
FE
AR2202-48
ON
OFF
/60Hz;3A
40V;50
~100-2
+12V; 11.5A
LINK
LINK
ACT
LINK
ACT
SA
ACT
E1
SLOT CARD
Issue 08 (2015-05-08)
135
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Figure 9-1 Same external power supply system for the RPS150 and router
AR2202-48
FE
ON
OFF
~100-2
/60Hz;3A
40V;50
+12V; 11.5A
LINK
LINK
ACT
ACT
LINK
ACT
SA
E1
SLOT CARD
Figure 9-2 Different external power supply systems for the RPS150 and router
AR2202-48
FE
ON
OFF
~100-2
/60Hz;3A
40V;50
+12V; 11.5A
LINK
LINK
ACT
ACT
LINK
ACT
SA
E1
SLOT CARD
Insert the AC terminal locking latch into the jack on the rear panel of the router.
2.
3.
Issue 08 (2015-05-08)
136
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
----End
Issue 08 (2015-05-08)
137
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Context
NOTICE
l The ground cable of a router must be correctly connected to protect the router against
lightning and interference.
l Do not power on the router before you finish connecting cables.
Phillips screwdriver
Multimeter
Ground cable
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Connect the ground cable.
1.
Use a Phillips screwdriver to remove the M4 screw from the ground point on the rear panel
of the router. Keep the M4 screw in an appropriate place for later use.
2.
Align the M4 lug of the ground cable with the tapped hole on the ground point, and then
secure the ground cable with the M4 screw.
3.
Connect the M6 lug of the ground cable to a ground point on the cabinet.
AR2202-48FE
ON
+12V; 11.5A
LINK
LINK
LINK
ACT
ACT
ACT
SA
SLOT CARD
OFF
E1
~100-240V;50/60Hz;3A
Ground cable
ON
ON
OFF
OFF
----End
Follow-up Procedure
Perform the following operations after connecting the ground cable:
Issue 08 (2015-05-08)
138
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Check that the ground cable is securely connected to the ground points.
Use a multimeter to measure the resistance between the ground points at two ends of the
ground cable. The resistance must be smaller than 5 ohm.
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Console cable
Procedure
Step 1 Connect the console cable.
1.
Connect the RJ45 connector of the console cable to the CON/AUX interface (RJ45) of the
router.
2.
Connect the DB9 connector of the console cable to the serial interface (COM) of a
management PC.
COM
Console cable
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
GE1
PWR
CON/AUX
SYS
EN
WAN
EN
L/A
ACT
RPS
AR2200 Series
MANAGE
GE0
----End
Issue 08 (2015-05-08)
139
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Follow-up Procedure
After connecting the console cable, configure the serial port communication software on the
management PC, so that you can log in to the command line interface (CLI) of the router. The
following describes how to set the serial port communication software on the Windows XP and
Windows 7 operating systems.
l
Windows XP
1.
2.
Create a connection, select a serial port, and configure the following parameter
settings:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bit: 1
Flow control: None
3.
Click OK. The router copyright statement is displayed on the HyperTerminal. Enter
the default user account admin and password Admin@huawei as prompted to log in
to the CLI of the router.
Windows 7
The Windows 7 operating system does not provide the HyperTerminal. You can download
free HyperTerminal software, such as PuTTY, from the Internet. The following example
describes how to use the PuTTY software.
Issue 08 (2015-05-08)
1.
Download the PuTTY software to the PC and double-click it to run the software.
2.
3.
140
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
4.
Click Open. The router copyright statement is displayed. Enter the default user
account admin and password Admin@huawei as prompted to log in to the CLI of
the router.
For details on how to log in to the router through the console interface, see Logging In to the
System for the First Time.
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Diagonal pliers
Cable ties
Issue 08 (2015-05-08)
141
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Marker
Procedure
Step 1 Select Ethernet cables of appropriate quantity and lengths according to the number of ports and
measured cabling distances.
Step 2 Attach temporary labels to both ends of each Ethernet cable and write numbers on the labels to
identify the Ethernet cables. For details, see 14.5.3 Engineering Labels for Network Cables.
Step 3 Lead the Ethernet cables into the cabinet from the top cable inlet (for overhead cabling) or bottom
cable inlet (for on-ground cabling), and route the cables from one side of the cabinet.
Step 4 Connect one end of an Ethernet cable to an Ethernet interface of the router and the other end to
an Ethernet interface of the remote device.
12
13
14
10
11
15
12
13
16
14
15
17
16
17
18
18
19
19
20
21
20
22
23
21
24
25
22
26
27
23
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
GE1
PWR
CON/AUX
SYS
EN
WAN
EN
L/A
ACT
RPS
AR2200 Series
MANAGE
GE0
Network cable
Ethernet interface of
the remote device
Step 5 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 6 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm away
from the connectors at both ends.
----End
Follow-up Procedure
Check the following items after connecting Ethernet cables:
l
Labels are correctly filled and securely attached to cables, with texts facing the same
direction.
Issue 08 (2015-05-08)
142
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
CAUTION
Invisible laser beams will cause eye damage. Do not look into bores of optical modules or
connectors of optical fibers without eye protection.
NOTICE
l A router must use Huawei-certified optical modules. Non-Huawei-certified optical modules
cannot ensure transmission reliability and may affect service stability. Huawei is not
responsible for any problem caused by the use of non-Huawei-certified optical modules and
will not fix such problems.
l Do not over bend optical fibers. The bend radius of an optical fiber should be no less than
40 mm.
l Do not bundle optical fibers too tight. Otherwise, optical fiber performance may be degraded,
affecting communications between devices.
Procedure
Step 1 Gently push an optical module into an optical interface until you hear a click.
NOTE
If the optical module cannot be completely inserted into the optical interface, do not force it into the
interface. Turn the optical module 180 degrees over and try again.
143
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTE
Place the dust plug in an appropriate place. After optical fibers are removed from the optical module, cover
the optical module with the dust plug to protect it from dust.
Step 3 Before connecting optical fibers, attach temporary labels on both ends of each optical fiber to
identify them. For details on how to make labels of optical fibers, see 14.5.2 Engineering Labels
for Optical Fibers.
Step 4 Remove the dust caps from the fiber connectors. Connect one end of the optical fiber to the
optical module and the other end to the remote device.
NOTE
Connect the receive and transmit ends of the fiber connector according to the identifiers on receive and
transmit bores of the optical module. Do not connect the two ends reversely.
L/A
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
GE1
PWR
CON/AUX
SYS
EN
WAN
EN
L/A
ACT
RPS
AR2200 Series
MANAGE
GE0
Optical fibers
Optical interface of
the remote device
Step 5 Arrange the optical fibers to make them parallel and bundle them with fiber binding tape at an
interval of 150 mm to 300 mm.
Step 6 Replace all the temporary labels with formal labels on the optical fibers.
----End
DANGER
To avoid electric shock, do not connect power cables while the power is on.
Issue 08 (2015-05-08)
144
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
l Do not power on a router before you finish connecting power cables and network cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
The AC power cable parameters vary in different countries or regions. The figures in this section are for
reference only and may differ from the cables delivered.
AC Power Cable
Procedure
Step 1 Verify that the router is reliably grounded.
Step 2 Set the power switch to OFF.
Step 3 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 4 Connect the AC power cable.
1.
Connect one end of the AC power cable to the power socket on the router.
2.
ON
OFF
~100-240V;50/60Hz;3A
AR2202-48FE
ON
+12V; 11.5A
LINK
LINK
LINK
ACT
ACT
ACT
SA
SLOT CARD
OFF
E1
~100-240V;50/60Hz;3A
AC Power Cable
AC power outlet
Step 5 Connect the AC terminal locking latch.
1.
Insert the AC terminal locking latch into the jack on the rear panel of the router.
2.
Issue 08 (2015-05-08)
145
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
3.
ON
OFF
~100-2
/60H
40V;50
z;3A
/60H
40V;50
z;3A
/60H
40V;50
z;3A
ON
OFF
~100-2
ON
OFF
~100-2
----End
Follow-up Procedure
Perform the following operations after connecting the AC power cable:
l
Verify that the AC power cable is securely connected to the power socket on the router.
If multiple routers are installed, attach labels to both ends of each power cable and write
numbers on the labels to identify them.
Issue 08 (2015-05-08)
146
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Procedure
Turn on the power switch of the power supply system, and then turn on the power switch
on the router to start the router.
After the router starts, check indicators on the front panel to check whether the router runs
normally. Figure 9-3 describes the indicator states when the router is running normally.
Figure 9-3 Normal indicator states on the router
PWR
SYS
WAN
RPS
AR2200 Series
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
GE1
PWR
CON/AUX
SYS
EN
WAN
EN
L/A
ACT
RPS
AR2200 Series
MANAGE
GE0
Indicator
Description
PWR
SYS
NOTICE
Powering off the router will interrupt all the services on the router. Exercise caution when
you perform this operation.
Issue 08 (2015-05-08)
147
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Turn off the power switch on the router, and then turn off the power switch of the power
supply system.
----End
Follow-up Procedure
After the router starts, you can log in to its CLI to configure, manage, and maintain the router.
For details, see the CLI-based Configuration.
Issue 08 (2015-05-08)
148
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
10
Issue 08 (2015-05-08)
149
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
NOTICE
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Seen from the front panel of the router, the airflow of the router is left to right.
l If multiple routers are installed in a cabinet, it is recommended that at least 1 U of space (1
U = 44.45 mm) be kept between two routers. These routers must have the same airflow
direction; otherwise, heat dissipation is affected by hot air circulation.
Make sure the following before the installation:
l
The router installation position in the cabinet is determined and arranged properly.
The router to be installed is available and located near the cabinet for convenient movement.
Phillips screwdriver
Flat-head screwdriver
Floating nuts
Mounting brackets
M4 screws
M6 screws
Procedure
Step 1 Use a Phillips screwdriver to fix the mounting brackets to both sides of the router with M4
screws.
NOTE
The mounting brackets can be installed close to the front panel or rear panel.
Issue 08 (2015-05-08)
150
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Step 2 Install two floating nuts on each front mounting rail. Leave a mounting hole between the two
floating nuts on the same mounting rail.
NOTE
l The length of three adjacent mounting holes may not be 1 U. Observe the scale ticks on the mounting
rails when installing floating nuts.
l You can use a flat-head screwdriver to install floating nuts.
h4
1U
Step 3 Move the router into the cabinet. Support the bottom of the router with one hand and tighten the
M6 screws on the mounting brackets with the other hand. Tighten the lower screws first, and
then the upper screws.
----End
Issue 08 (2015-05-08)
151
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
NOTICE
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Seen from the front panel of the router, the airflow of the router is left to right.
l If multiple routers are installed in a cabinet, it is recommended that at least 1 U of space (1
U = 44.45 mm) be kept between two routers. These routers must have the same airflow
direction; otherwise, heat dissipation is affected by hot air circulation.
Make sure the following before the installation:
l
The router installation position in the cabinet is determined and arranged properly.
The router to be installed is available and located near the cabinet for convenient movement.
Phillips screwdriver
Flat-head screwdriver
Floating nuts
Mounting brackets
M4 screws
M6 screws
Procedure
Step 1 Use a Phillips screwdriver to fix the mounting brackets to both sides of the router with M4
screws.
NOTE
The mounting brackets can be installed close to the front panel or rear panel.
Issue 08 (2015-05-08)
152
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
Step 2 Install two floating nuts on each of the front and rear mounting rails. Leave a mounting hole
between the two floating nuts on the same mounting rail.
NOTE
l The length of three adjacent mounting holes may not be 1 U. Observe the scale ticks on the mounting
rails when installing floating nuts.
l The floating nuts on the rear mounting rails must be aligned with the floating nuts on the front mounting
rails.
l You can use a flat-head screwdriver to install floating nuts.
Issue 08 (2015-05-08)
153
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
h8
1U
1U
Step 3 Fix the mounting bracket guide rails on the rear mounting rails.
Move the router into the cabinet, align the rear mounting brackets with the guide rails, and
gently push the router into the cabinet until the front mounting brackets are completely
attached to the front mounting rails.
2.
a
b
----End
Issue 08 (2015-05-08)
154
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
NOTICE
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Seen from the front panel of the router, the airflow of the router is left to right.
l If multiple routers are installed in a cabinet, it is recommended that at least 1 U of space (1
U = 44.45 mm) be kept between two routers. These routers must have the same airflow
direction; otherwise, heat dissipation is affected by hot air circulation.
Make sure the following before the installation:
l
The router installation position in the cabinet is determined and arranged properly.
The router to be installed is available and located near the cabinet for convenient movement.
Phillips screwdriver
Flat-head screwdriver
Floating nuts
Mounting brackets
M4 screws
M5 screws
M6 screws
Procedure
Step 1 Use a Phillips screwdriver to fix the mounting brackets to both sides of the router with M4
screws.
NOTE
The mounting brackets can be installed close to the front panel or rear panel.
Issue 08 (2015-05-08)
155
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Step 2 Mark the positions of L-shaped guide rails and floating nuts.
nU (n1)
Ensure that the floating nuts on the left and right are on the same horizontal plane. Use a
flat-head screwdriver to install four floating nuts in the marked positions on the front
mounting rails, two on left and two on right.
2.
The bottom edges of the L-shaped guide rails must be in line with the bottom edges of the
marked mounting holes. Use a Phillips screwdriver to fix the L-shaped guide rails in the
marked positions with M5 screws.
Issue 08 (2015-05-08)
156
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
a
b
Move the router into the cabinet, place the router on the L-shaped guide rails, and gently
push the router into the cabinet until the mounting brackets are completely attached to the
front mounting rails.
2.
a
b
----End
Issue 08 (2015-05-08)
157
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Context
NOTICE
l Ensure that the desk is flat and properly grounded.
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Do not place other objects on the router.
Procedure
Step 1 Attach four rubber pads in the imprinted round areas marked plus (+) signs at the bottom of the
router.
----End
Issue 08 (2015-05-08)
158
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
DANGER
Before drilling holes on a wall, make sure that no power cable is routed in the wall. Otherwise,
power cables in the wall may cause personal injury.
NOTICE
l The interface side of a wall-mounted router must face down to protect interfaces from water.
l Screws must be installed solid in the wall; otherwise, the wall-mounted router may fall down
after cables are connected.
l Ensure that there are no flammable or explosive materials near the router and no obstructions
within 100 mm around the router.
l Install the router at an appropriate height to ensure that the indicators can be observed easily.
Measuring tape
Marker
Hammer drill
Claw hammer
Phillips screwdriver
Procedure
Step 1 Use a measuring tape to determine positions of two mounting holes, keep the two positions
aligned, and mark the positions with a marker.
Issue 08 (2015-05-08)
159
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
270mm
Choose an appropriate drill bit according to the diameter of the mounting screws. The
diameter of the mounting screws cannot exceed 4 mm.
2.
3.
Use a Phillips screwdriver to screw the mounting screws into the wall anchors. Leave the
screws protruding 2 mm from the wall.
90
90
c
2mm
Step 3 Align the mounting holes on the rear of the router with mounting screws and hang the router on
the mounting screws.
Issue 08 (2015-05-08)
160
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
----End
NOTICE
l All cards are hot swappable.
l Vacant slots in the router must be covered with filler panels.
l When installing a card, slowly push it into the slot. If you feel resistance or find the card
inclined, pull the card out and push it into the slot again. Do not push the card with force;
otherwise, the connectors on the card and backplane may be damaged.
l A card can only be installed in a router that supports this card. For the specific cards supported
by different routers, see Cards in the Hardware Description.
Phillips screwdriver
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Loosen the captive screw on the filler panel and remove the filler panel.
Issue 08 (2015-05-08)
161
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Step 3 Perform the following steps depending on whether slots are combined:
l
The methods for installing SIC and WSIC cards into SIC and WSIC slots are the same. The following
procedures install a SIC card into a SIC slot.
1.
Rotate the ejector levers outward and slide the card into the slot horizontally along
the guide rails until the card panel is closely attached to the router panel.
2.
Rotate the ejector levers inward until the card is completely seated in the slot, and then
tighten the captive screws on both sides of the card.
b
2
STAT
STAT
LINK/ACT
GE0
FE0
GE1
LINK/ACT
FE2
FE1
GE0
LINK/ACT
LINK/ACT
FE2
FE1
FE0
GE1
G
ON
Hz;2A
0V;50/60
STAT
0
LINK/ACT
LINK/ACT
FE5
FE4
FE0
GE0
OFF
FE1
FE2
FE6
~100-24
FE7
FE3
GE1
CON/AUX
Slots of a router can be combined into a larger slot. For example, two SIC slots can be combined into
a WSIC slot, and two SIC slots and the WSIC slot below them can be combined into an XSIC slot.
In this example, two SIC slots are combined into a WSIC slot.
1.
Loosen the captive screw on the guide rail between the two SIC slots.
2.
Remove the guide rail to combine the two SIC slots into a WSIC slot.
3.
Slide the WSIC card into the WSIC slot horizontally along the guide rails until the
card is completely seated in the slot. Rotate the ejector levers inward to lock the card
in the slot, and then tighten the captive screws on both sides.
c
1
FE4
FE0
GE0
FE1
FE2
FE5
FE6
FE7
FE3
GE1
GE0
GE1
2
ON
OFF
FE4
FE0
GE0
FE1
FE2
FE5
FE6
Hz;2
0V;50/60
~100-24
FE7
FE3
GE1
CON/AUX
----End
Issue 08 (2015-05-08)
162
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
The procedures and methods for installing antennas on different routers are the same. An AR1220VW
router is used as an example here.
Wi-Fi antenna
Procedure
Step 1 Connect the Wi-Fi antennas to the SMA connectors on the rear panel of the router.
ON
)
NEG(-) RTN(+
OFF
FE4
FE0
GE0
FE1
FE5
~100-240
V;50/60H
z;2A
FE7
FE6
FE3
FE2
GE1
CON/AUX
Step 2 Adjust positions of the antennas to obtain the optimal wireless transmission and receiving
performance.
l
If the router is placed on a desk, make the Wi-Fi antennas vertical to the desk.
ON
)
NEG(-) RTN(+
OFF
FE4
FE0
GE0
FE1
FE2
FE5
FE6
~100-240
V;50/60H
z;2A
FE7
FE3
GE1
CON/AUX
Issue 08 (2015-05-08)
If the router is mounted on a wall, make the Wi-Fi antennas parallel with the wall.
163
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
----End
Issue 08 (2015-05-08)
164
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
NEG(-)
RTN(+)
AP
AP
NOTE
l LAN interfaces FE4 to FE7 of the AR1220V, AR1220W, and AR1220VW routers support PoE power
supply.
l LAN interfaces GE4 to GE7 of the AR1220EV and AR1220EVW support PoE power supply.
l The methods for connecting a PoE power supply to different AR routers are the same. An AR1220V
router is used as an example here.
The PoE power supply is not included in the installation accessory package and needs to be purchased
separately.
Procedure
Step 1 Connect one end of the PoE power supply to the PoE power jack of the router and the other end
to an AC power outlet.
Issue 08 (2015-05-08)
165
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
NEG(-)
RTN(+)
NEG(-)
RTN(+)
AP
AP
----End
Only the AR2204 and AR2220E can connect to an RPS150 power supply.
An RPS150 is a redundant power supply system that provides power redundancy for the
connected routers to ensure uninterrupted services. When the internal power module of a router
fails, the RPS150 can detect the power failure and supply power to the router immediately. The
router can continue running without a restart, which improves system reliability.
An RPS150 can provide power redundancy for a router to ensure uninterrupted services.
l
If the RPS150 and router are connected to the same external power supply system, the
RPS150 can prevent service interruption caused by failures of the router's internal power
module.
If the RPS150 and router are connected to different external power supply systems, the
RPS150 can prevent service interruption caused by failure of the router's internal power
module and external power supply system. Therefore, this deployment is more reliable.
DANGER
To avoid electric shock, do not connect power cables while the power is on.
Issue 08 (2015-05-08)
166
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
NOTICE
l
Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
Phillips screwdriver
Flat-head screwdriver
Floating nuts
Mounting brackets
Screws
RPS cable
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Use a Phillips screwdriver to fix the front mounting brackets at both sides of the RPS150 with
M4 screws.
l The length of three adjacent mounting holes may not be 1 U. Observe the scale ticks on the mounting
rails when installing floating nuts.
l You can use a flat-head screwdriver to install floating nuts.
Issue 08 (2015-05-08)
167
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
h4
1U
Step 4 Support the bottom of the RPS150 with one hand and tighten the screws on the mounting brackets
with the other hand. Tighten the lower screws first, and then the upper screws.
Put the TOP side of the RPS cable plugs upwards. Connect one end of the RPS cable to the
RPS input interface on the router, and connect the other end to the RPS output interface on
the RPS150.
2.
Tighten the captive screws at two sides of the RPS cable plugs clockwise.
Issue 08 (2015-05-08)
168
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
Figure 10-5 Different external power supply systems for the RPS150 and router
Issue 08 (2015-05-08)
169
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Insert the AC terminal locking latch into the jack on the rear panel of the router.
2.
3.
----End
170
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
Context
l
When an AR2204 or AR2220E router needs to provide the voice service, install a DSP card
and a voice daughter card in the router.
When an AR2220 router needs to provide the voice service, install a DSP card in the router.
NOTICE
To install the DSP card and voice daughter card, first remove the chassis cover. Opening the
chassis for this purpose does not affect warranty of the router.
NOTE
The methods for installing a DSP card and voice daughter card in different router models are the same.
The following procedure installs a DSP card and voice daughter card in an AR2204 router.
Tools
l
Phillips screwdriver
Procedure
Step 1 Set the power switch to OFF.
Step 2 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 3 Use a Phillips screwdriver to remove the screws on the top cover and two sides of the chassis
and remove the chassis cover.
Issue 08 (2015-05-08)
171
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
AR2200
+12V; 11.5A
EN
EN
CON/AUX
Series
RST
ACT
ON
LINK
PWR
SYS
POE
OFF
GE1
GE0
ACT
micro SD
GE2
50/60Hz;2A
~100-240V;
1
2
AR2200
+12V; 11.5A
EN
EN
CON/AUX
Series
RST
ACT
ON
LINK
PWR
SYS
POE
OFF
GE1
micro SD
ACT
GE2
GE0
50/60Hz;2A
~100-240V;
Remove the four screws around the voice daughter card slot with the Phillips screwdriver.
2.
Take out the four studs delivered with the voice daughter card from the package. Align the
studs with the tapped holes around the daughter card slot and use a hex socket wrench to
tighten the studs.
3.
Insert the voice daughter card into the slot until it is completely seated in the slot.
4.
Insert the four screws into the tapped holes and tighten the screws in the studs to secure the
voice daughter card in the slot.
Issue 08 (2015-05-08)
172
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
AR2200
+12V; 11.5A
EN
EN
CON/AUX
Series
RST
ACT
ON
LINK
PWR
SYS
POE
OFF
GE1
micro SD
ACT
GE2
GE0
;50/60Hz;2
~100-240V
Step 6 Install the chassis cover and tighten the screws on the chassis.
----End
Follow-up Procedure
Verify whether the voice daughter card is installed correctly.
1.
2.
3.
If the following information is displayed, the voice daughter card is installed correctly and
working normally.
AR2204's Device status:
Slot Sub Type
Online
Power
Register
Alarm
Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
TDM-SWITCH
Present PowerOn
Registered
Normal
NA
2.
3.
If the following information is displayed, the DSP card is installed correctly and working
normally.
Symbol:
Channel NO.
---------------------------------------------------------------------0000-0049 00000 00000 00000 00000 00000 00000 00000 00000 00000
Issue 08 (2015-05-08)
173
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
00000
0050-0099 00000 00000 0000
Total:
64 DSP
channel
64 idle, 0 G.711 Busy, 0 All Busy, 0 Wastage, 0
Fault,
0
IP loopback, 0 PCM loopback, 0 prohibited
Impact tool
Diagonal pliers
Phillips screwdriver
Protective units
M6 screws
NOTE
The cable management strip holder, cable management strip, protective units, and M6 screws are not
included in the installation accessory package delivered with a card and need to be purchased separately.
Procedure
Step 1 Use a Phillips screwdriver and M6 screws to fix the cable management strip holder onto
mounting rails of the cabinet, as shown in Figure 10-6.
Issue 08 (2015-05-08)
174
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Figure 10-6 Installing the cable management strip holder onto the cabinet
Step 2 Put the unshielded network cable connected to the local device through the cable inlet at one
side of the cable management strip holder, and put the unshielded network cable connected to
the remote device through the cable inlet at the other side of the cable management strip holder.
See Figure 10-7.
Issue 08 (2015-05-08)
175
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
The following describes connection of one unshielded network cable. Connect all the unshielded network
cables in the same way.
1.
Use a pair of diagonal pliers to strip off about 15 cm of insulation coating of the unshielded
network cable.
2.
Divide the four twisted pairs of the cable into eight wires and arrange them orderly.
3.
At the local device side, put each two wires through a pair of wire dividers at the left side
of the cable management strip and lead the wires into the wire slots at the left side. At the
remote device side, put each two wires through a pair of wire dividers at the right side of
the cable management strip and lead the wires into the wire slots at the right side. See
Figure 10-8
Issue 08 (2015-05-08)
176
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
NOTICE
The two wires in the same wire slot on the cable management strip must be the same color.
5LJKWVLGH
:LUHGLYLGHU
:LUHGLYLGHU
/HIWVLGH
4.
Issue 08 (2015-05-08)
Use an impact tool to push the wires into the wire slots. Press a wire with the impact tool
until you hear a click, as shown in Figure 10-9.
177
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
5.
Install a protective unit on each wire slot with wires connected. Keep a protective unit
vertical with a wire slot (with the diode of the protective unit facing the arrowhead on the
wire slot), and insert the protective unit until it is completely in the wire slot, as shown in
Figure 10-10.
Figure 10-10 Installing protective units
6.
Issue 08 (2015-05-08)
Install the cable management strip onto the cable management strip holder, making the end
with a shorter hook face up and the end with longer hook face down, as shown in Figure
10-11. Gently shake the cable management strip. If the cable management strip is still fixed
on the holder, it is installed properly.
178
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Figure 10-11 Installing the cable management strip on the cable management strip holder
0
9
0
9
0
9
0
9
----End
Issue 08 (2015-05-08)
179
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Context
NOTICE
l The ground cable of a router must be correctly connected to protect the router against
lightning and interference.
l Do not power on the router before you finish connecting cables.
Phillips screwdriver
Multimeter
Ground cable
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Connect the ground cable.
1.
Use a Phillips screwdriver to remove the M4 screw from the ground point on the rear panel
of the router. Keep the M4 screw in an appropriate place for later use.
2.
Align the M4 lug of the ground cable with the tapped hole on the ground point, and then
secure the ground cable with the M4 screw.
3.
Connect the M6 lug of the ground cable to a ground point on the cabinet.
ON
EN
EN
CON/AUX
management
GE0
GE1
FE0
FE1
FE2
FE3
FE4
FE5
FE6
OFF
FE7
~100-240V;50/60Hz;2A
Ground cable
~100-24
Hz
0V;50/60
;2A
~100-24
Hz
0V;50/60
;2A
----End
Follow-up Procedure
Perform the following operations after connecting the ground cable:
Issue 08 (2015-05-08)
180
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
Check that the ground cable is securely connected to the ground points.
Use a multimeter to measure the resistance between the ground points at two ends of the
ground cable. The resistance must be smaller than 5 ohm.
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Console cable
Procedure
Step 1 Connect the console cable.
1.
Connect the RJ45 connector of the console cable to the CON/AUX interface (RJ45) of the
router.
2.
Connect the DB9 connector of the console cable to the serial interface (COM) of a
management PC.
Issue 08 (2015-05-08)
181
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
EN
CON/AUX
ON
EN
EN
management
GE0
CON/AUX
GE1
FE0
FE1
FE2
FE3
FE4
FE5
FE6
FE7
OFF
~100-240V;50/60Hz;2A
COM
Console cable
----End
Follow-up Procedure
After connecting the console cable, configure the serial port communication software on the
management PC, so that you can log in to the command line interface (CLI) of the router. The
following describes how to set the serial port communication software on the Windows XP and
Windows 7 operating systems.
l
Windows XP
1.
2.
Create a connection, select a serial port, and configure the following parameter
settings:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bit: 1
Flow control: None
3.
Click OK. The router copyright statement is displayed on the HyperTerminal. Enter
the default user account admin and password Admin@huawei as prompted to log in
to the CLI of the router.
Windows 7
The Windows 7 operating system does not provide the HyperTerminal. You can download
free HyperTerminal software, such as PuTTY, from the Internet. The following example
describes how to use the PuTTY software.
Issue 08 (2015-05-08)
182
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
1.
Download the PuTTY software to the PC and double-click it to run the software.
2.
3.
4.
Click Open. The router copyright statement is displayed. Enter the default user
account admin and password Admin@huawei as prompted to log in to the CLI of
the router.
For details on how to log in to the router through the console interface, see Logging In to the
System for the First Time.
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Issue 08 (2015-05-08)
183
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Diagonal pliers
Cable ties
Marker
Procedure
Step 1 Select Ethernet cables of appropriate quantity and lengths according to the number of ports and
measured cabling distances.
Step 2 Attach temporary labels to both ends of each Ethernet cable and write numbers on the labels to
identify the Ethernet cables. For details, see 14.5.3 Engineering Labels for Network Cables.
Step 3 Lead the Ethernet cables into the cabinet from the top cable inlet (for overhead cabling) or bottom
cable inlet (for on-ground cabling), and route the cables from one side of the cabinet.
Step 4 Connect one end of an Ethernet cable to an Ethernet interface of the router and the other end to
an Ethernet interface of the remote device.
FE0
FE1
FE2
FE3
AR1220
ON
EN
EN
CON/AUX
management
GE0
GE1
FE0
FE1
FE2
FE3
FE4
FE5
FE6
FE7
OFF
~100-240V;50/60Hz;2A
Network cable
Ethernet interface of
the remote device
Step 5 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 6 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm away
from the connectors at both ends.
----End
Follow-up Procedure
Check the following items after connecting Ethernet cables:
Issue 08 (2015-05-08)
184
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Labels are correctly filled and securely attached to cables, with texts facing the same
direction.
CAUTION
Invisible laser beams will cause eye damage. Do not look into bores of optical modules or
connectors of optical fibers without eye protection.
NOTICE
l A router must use Huawei-certified optical modules. Non-Huawei-certified optical modules
cannot ensure transmission reliability and may affect service stability. Huawei is not
responsible for any problem caused by the use of non-Huawei-certified optical modules and
will not fix such problems.
l Do not over bend optical fibers. The bend radius of an optical fiber should be no less than
40 mm.
l Do not bundle optical fibers too tight. Otherwise, optical fiber performance may be degraded,
affecting communications between devices.
NOTE
The methods for connecting optical modules and optical fibers to different routers are the same. The
following uses an AR2220 router as an example to describe how to connect optical modules and optical
fibers.
Procedure
Step 1 Gently push an optical module into an optical interface until you hear a click.
NOTE
If the optical module cannot be completely inserted into the optical interface, do not force it into the
interface. Turn the optical module 180 degrees over and try again.
Issue 08 (2015-05-08)
185
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Place the dust plug in an appropriate place. After optical fibers are removed from the optical module, cover
the optical module with the dust plug to protect it from dust.
Step 3 Before connecting optical fibers, attach temporary labels on both ends of each optical fiber to
identify them. For details on how to make labels of optical fibers, see 14.5.2 Engineering Labels
for Optical Fibers.
Step 4 Remove the dust caps from the fiber connectors. Connect one end of the optical fiber to the
optical module and the other end to the remote device.
NOTE
Connect the receive and transmit ends of the fiber connector according to the identifiers on receive and
transmit bores of the optical module. Do not connect the two ends reversely.
management
ON
AR2200 Series
STATUS
OFF
SYS
micro SD
LINK
management
EN
PWR150A
~100-240V;
50/60Hz;2A
ACT
GE0
GE1
GE2
ACT
EN
CON/AUX
RST
Optical fibers
Optical interface of
the remote device
Step 5 Arrange the optical fibers to make them parallel and bundle them with fiber binding tape at an
interval of 150 mm to 300 mm.
Issue 08 (2015-05-08)
186
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Step 6 Replace all the temporary labels with formal labels on the optical fibers.
----End
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on a router before you finish connecting power cables and network cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
The AC power cable parameters vary in different countries or regions. The figures in this section are for
reference only and may differ from the cables delivered.
AC Power Cable
Procedure
Step 1 Verify that the router is reliably grounded.
Step 2 Set the power switch to OFF.
Step 3 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 4 Connect the AC power cable.
1.
Connect one end of the AC power cable to the power socket on the router.
2.
Issue 08 (2015-05-08)
187
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
ON
EN
EN
CON/AUX
AR1220
1
management
GE0
GE1
FE0
FE1
FE2
FE3
FE4
FE5
FE6
FE7
OFF
~100-240V;50/60Hz;2A
AC Power Cable
AC power outlet
Step 5 Connect the AC terminal locking latch.
1.
Insert the AC terminal locking latch into the jack on the rear panel of the router.
2.
3.
Issue 08 (2015-05-08)
188
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
----End
Follow-up Procedure
Perform the following operations after connecting the AC power cable:
l
Verify that the AC power cable is securely connected to the power socket on the router.
If multiple routers are installed, attach labels to both ends of each power cable and write
numbers on the labels to identify them.
Issue 08 (2015-05-08)
189
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Routers
Hardware Installation and Maintenance Guide
Context
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on a router before you finish connecting power cables and network cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
l The DC power cable parameters vary in different countries or regions. The figures in this section are
for reference only and may differ from the cables delivered.
l The methods for connecting DC power cables to different routers are the same. The following procedure
connects DC power cables to the AR1220 DC model.
Phillips screwdriver
DC power cables
Procedure
Step 1 Verify that the router is reliably grounded.
Step 2 Set the power switch to OFF.
Step 3 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 4 Connect the DC power cables.
1.
Connect one end of the DC power cables to the DC power module of the router.
NOTE
The black cable is the -48 V return ground cable and must be connected to the RTN(+) terminal. The
blue cable is the -48 V power cable and must be connected to the NEG(-) terminal.
2.
Issue 08 (2015-05-08)
Connect the other end of the power cables to output terminals of the external DC power
supply system.
190
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
ON
EN
EN
CON/AUX
NEG(-)
RTN(+)
1
management
GE0
GE1
FE0
FE1
FE2
FE3
FE4
FE5
FE6
OFF
FE7
-48--60V:3A
NEG(-) RTN(+)
DC power cables
DC power supply system
----End
Follow-up Procedure
Perform the following operations after connecting the DC power cables:
l
Verify that DC power cables are securely connected to the power terminals.
If multiple routers are installed, attach labels to both ends of each power cable and write
numbers on the labels to identify them.
Procedure
Turn on the power switch of the power supply system, and then turn on the power switch
on the router to start the router.
After the router starts, check indicators on the front panel to check whether the router runs
normally. Figure 10-12 describes the indicator states when the router is running normally.
Figure 10-12 Normal indicator states on the router
SYS
WAN
SYS
ACT
WAN
RST
AR1200 Series
Issue 08 (2015-05-08)
191
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers10 Installing the AR1200 Series/AR2204/AR2220E/AR2220
Hardware Installation and Maintenance Guide
Routers
Indicator
Description
SYS
NOTICE
Powering off the router will interrupt all the services on the router. Exercise caution when
you perform this operation.
Turn off the power switch on the router, and then turn off the power switch of the power
supply system.
----End
Follow-up Procedure
After the router starts, you can log in to its CLI to configure, manage, and maintain the router.
For details, see the CLI-based Configuration.
Issue 08 (2015-05-08)
192
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
11
Installing AR2240/AR3260/AR3670
Routers
Issue 08 (2015-05-08)
193
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
l Leave at least 50 mm of clearance around the router for heat dissipation.
l Seen from the front panel of the router, the airflow of the router is left to right.
l If multiple routers are installed in a cabinet, it is recommended that at least 1 U of space (1
U = 44.45 mm) be kept between two routers. These routers must have the same airflow
direction; otherwise, heat dissipation is affected by hot air circulation.
Make sure the following before the installation:
l
The router installation position in the cabinet is determined and arranged properly.
The router to be installed is available and located near the cabinet for convenient movement.
NOTE
The procedures and methods for installing AR3260 and AR3670 routers into a cabinet are the same. The
following procedure installs an AR3260 router into cabinet.
Phillips screwdriver
Flat-head screwdriver
Floating nuts
Mounting brackets
M4 screws
M6 screws
Procedure
Step 1 Use a Phillips screwdriver to fix the mounting brackets to both sides of the router with M4
screws.
NOTE
The mounting brackets can be installed close to the front panel or rear panel.
Issue 08 (2015-05-08)
194
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 2 Mark the positions of L-shaped guide rails and floating nuts.
l An AR2240 router is 2 U high, which is the distance between six mounting holes. Mark the
mounting holes for L-shaped guide rails and floating nuts with a marker.
l An AR3260 router is 3 U high, which is the distance between nine mounting holes. Mark the
mounting holes for L-shaped guide rails and floating nuts with a marker.
Issue 08 (2015-05-08)
195
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
AR
nU (n1)
The methods for installing floating nuts and L-shaped guide rails for the AR2240 and AR3260 routers are
the same, except that the installation positions of the floating nuts and L-shaped guide rails differ. An
AR2240 router is used as an example here to describe the installation procedure.
1.
Use a flat-head screwdriver to install four floating nuts in the marked positions on the front
mounting rails, two on left and two on right. Ensure that the floating nuts on the left and
right are on the same horizontal plane.
2.
Use a Phillips screwdriver to fix the L-shaped guide rails in the marked positions with M5
screws. The bottom edges of the L-shaped guide rails must be in line with the bottom edges
of the marked mounting holes.
Issue 08 (2015-05-08)
196
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
a
b
Move the router into the cabinet, place the router on the L-shaped guide rails, and gently
push the router into the cabinet until the mounting brackets are completely attached to the
front mounting rails.
2.
a
b
Issue 08 (2015-05-08)
197
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
----End
NOTICE
l All cards are hot swappable.
l Vacant slots in the router must be covered with filler panels.
l When installing a card, slowly push it into the slot. If you feel resistance or find the card
inclined, pull the card out and push it into the slot again. Do not push the card with force;
otherwise, the connectors on the card and backplane may be damaged.
l A card can only be installed in a router that supports this card. For the specific cards supported
by different routers, see Cards in the Hardware Description.
Phillips screwdriver
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Loosen the captive screw on the filler panel and remove the filler panel.
Issue 08 (2015-05-08)
198
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 3 Perform the following steps depending on whether slots are combined:
l
The methods for installing SIC, WSIC, and XSIC cards into SIC, WSIC, and XSIC slots are the same.
The following procedures install a SIC card into a SIC slot.
1.
Rotate the ejector levers outward and slide the card into the slot horizontally along
the guide rails until the card panel is closely attached to the router panel.
2.
Rotate the ejector levers inward until the card is completely seated in the slot, and then
tighten the captive screws on both sides of the card.
Slots of a router can be combined into a larger slot. For example, two SIC slots can be combined into
a WSIC slot, and two SIC slots and the WSIC slot below them can be combined into an XSIC slot.
In this example, two SIC slots are combined into a WSIC slot.
Issue 08 (2015-05-08)
1.
Loosen the captive screw on the guide rail between the two SIC slots.
2.
Remove the guide rail to combine the two SIC slots into a WSIC slot.
3.
Slide the WSIC card into the WSIC slot horizontally along the guide rails until the
card is completely seated in the slot. Rotate the ejector levers inward to lock the card
in the slot, and then tighten the captive screws on both sides.
199
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
----End
NOTICE
l AC and DC power modules cannot be used together in the same router.
l A power module can be hot swapped.
l Vacant slots in the router must be covered with filler panels.
Phillips screwdriver
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Loosen the captive screw on the filler panel and remove the filler panel.
Step 3 Install a power module in the router.
Issue 08 (2015-05-08)
200
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
1.
Rotate the ejector levers on the power module outward and slide the power module into
the slot along the guide rails until the power module is completely attached to the router
panel.
2.
Rotate the ejector levers inward to lock the power module in the slot.
3.
Use a Phillips screwdriver to tighten the captive screws on the power module.
c
b
----End
Impact tool
Diagonal pliers
Phillips screwdriver
Protective units
M6 screws
NOTE
The cable management strip holder, cable management strip, protective units, and M6 screws are not
included in the installation accessory package delivered with a card and need to be purchased separately.
Procedure
Step 1 Use a Phillips screwdriver and M6 screws to fix the cable management strip holder onto
mounting rails of the cabinet, as shown in Figure 11-5.
Issue 08 (2015-05-08)
201
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Figure 11-5 Installing the cable management strip holder onto the cabinet
Step 2 Put the unshielded network cable connected to the local device through the cable inlet at one
side of the cable management strip holder, and put the unshielded network cable connected to
the remote device through the cable inlet at the other side of the cable management strip holder.
See Figure 11-6.
Issue 08 (2015-05-08)
202
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
The following describes connection of one unshielded network cable. Connect all the unshielded network
cables in the same way.
1.
Use a pair of diagonal pliers to strip off about 15 cm of insulation coating of the unshielded
network cable.
2.
Divide the four twisted pairs of the cable into eight wires and arrange them orderly.
3.
At the local device side, put each two wires through a pair of wire dividers at the left side
of the cable management strip and lead the wires into the wire slots at the left side. At the
remote device side, put each two wires through a pair of wire dividers at the right side of
the cable management strip and lead the wires into the wire slots at the right side. See
Figure 11-7
Issue 08 (2015-05-08)
203
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
NOTICE
The two wires in the same wire slot on the cable management strip must be the same color.
5LJKWVLGH
:LUHGLYLGHU
:LUHGLYLGHU
/HIWVLGH
4.
Issue 08 (2015-05-08)
Use an impact tool to push the wires into the wire slots. Press a wire with the impact tool
until you hear a click, as shown in Figure 11-8.
204
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
5.
Install a protective unit on each wire slot with wires connected. Keep a protective unit
vertical with a wire slot (with the diode of the protective unit facing the arrowhead on the
wire slot), and insert the protective unit until it is completely in the wire slot, as shown in
Figure 11-9.
Figure 11-9 Installing protective units
6.
Issue 08 (2015-05-08)
Install the cable management strip onto the cable management strip holder, making the end
with a shorter hook face up and the end with longer hook face down, as shown in Figure
11-10. Gently shake the cable management strip. If the cable management strip is still fixed
on the holder, it is installed properly.
205
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Figure 11-10 Installing the cable management strip on the cable management strip holder
0
9
0
9
0
9
0
9
----End
Issue 08 (2015-05-08)
206
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Context
NOTICE
l The ground cable of a router must be correctly connected to protect the router against
lightning and interference.
l Do not power on the router before you finish connecting cables.
Phillips screwdriver
Multimeter
Ground cable
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Connect the ground cable.
1.
Use a Phillips screwdriver to remove the M4 screw from the ground point on the rear panel
of the router. Keep the M4 screw in an appropriate place for later use.
2.
Align the M4 lug of the ground cable with the tapped hole on the ground point, and then
secure the ground cable with the M4 screw.
3.
4
Connect the M6 lug of the ground cable to a ground point on the cabinet.
3
AR2240
Ground cable
----End
Issue 08 (2015-05-08)
207
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Follow-up Procedure
Perform the following operations after connecting the ground cable:
l
Check that the ground cable is securely connected to the ground points.
Use a multimeter to measure the resistance between the ground points at two ends of the
ground cable. The resistance must be smaller than 5 ohm.
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Console cable
Procedure
Step 1 Connect the console cable.
1.
Connect the RJ45 connector of the console cable to the CON/AUX interface (RJ45) of the
router.
2.
Connect the DB9 connector of the console cable to the serial interface (COM) of a
management PC.
Issue 08 (2015-05-08)
208
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
EN
CON/AUX
AR2200 Series
ON
STATUS
STATUS
OFF
~100-240V;50/60Hz;5A
PWR350A
10PWR 9PWR
11 SRU
12
F
A
N
GE1
SYS ACT
LINK0 LINK1
micro SD
ACT
SRU40
EN
ACT0 ACT1
GE0
GE1
EN
GE2
CON/AUX
RST
FAN
COM
Console cable
----End
Follow-up Procedure
After connecting the console cable, configure the serial port communication software on the
management PC, so that you can log in to the command line interface (CLI) of the router. The
following describes how to set the serial port communication software on the Windows XP and
Windows 7 operating systems.
l
Windows XP
1.
2.
Create a connection, select a serial port, and configure the following parameter
settings:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bit: 1
Flow control: None
3.
Click OK. The router copyright statement is displayed on the HyperTerminal. Enter
the default user account admin and password Admin@huawei as prompted to log in
to the CLI of the router.
Windows 7
The Windows 7 operating system does not provide the HyperTerminal. You can download
free HyperTerminal software, such as PuTTY, from the Internet. The following example
describes how to use the PuTTY software.
Issue 08 (2015-05-08)
209
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
1.
Download the PuTTY software to the PC and double-click it to run the software.
2.
3.
4.
Click Open. The router copyright statement is displayed. Enter the default user
account admin and password Admin@huawei as prompted to log in to the CLI of
the router.
For details on how to log in to the router through the console interface, see Logging In to the
System for the First Time.
NOTICE
l Do not power on the router before you finish connecting cables.
l Notice flags on interfaces when connecting cables. Incorrect cable connection may damage
interface modules or the router.
Issue 08 (2015-05-08)
210
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Diagonal pliers
Cable ties
Marker
Procedure
Step 1 Select Ethernet cables of appropriate quantity and lengths according to the number of ports and
measured cabling distances.
Step 2 Attach temporary labels to both ends of each Ethernet cable and write numbers on the labels to
identify the Ethernet cables. For details, see 14.5.3 Engineering Labels for Network Cables.
Step 3 Lead the Ethernet cables into the cabinet from the top cable inlet (for overhead cabling) or bottom
cable inlet (for on-ground cabling), and route the cables from one side of the cabinet.
Step 4 Connect one end of an Ethernet cable to an Ethernet interface of the router and the other end to
an Ethernet interface of the remote device.
GE2
AR2200 Series
ON
STATUS
STATUS
OFF
~100-240V;50/60Hz;5A
PWR350A
10PWR 9PWR
11 SRU
12
F
A
N
GE1
SYS ACT
LINK0 LINK1
micro SD
ACT
SRU40
EN
ACT0 ACT1
GE0
GE1
GE2
EN
CON/AUX
RST
FAN
Network cable
Ethernet interface of
the remote device
Step 5 Arrange the Ethernet cables to make them parallel, and then bundle them with cable ties. Use
diagonal pliers to cut off redundant cable ties.
Step 6 Remove the temporary labels from the Ethernet cables, and then attach formal labels 2 cm away
from the connectors at both ends.
----End
Follow-up Procedure
Check the following items after connecting Ethernet cables:
Issue 08 (2015-05-08)
211
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Labels are correctly filled and securely attached to cables, with texts facing the same
direction.
CAUTION
Invisible laser beams will cause eye damage. Do not look into bores of optical modules or
connectors of optical fibers without eye protection.
NOTICE
l A router must use Huawei-certified optical modules. Non-Huawei-certified optical modules
cannot ensure transmission reliability and may affect service stability. Huawei is not
responsible for any problem caused by the use of non-Huawei-certified optical modules and
will not fix such problems.
l Do not over bend optical fibers. The bend radius of an optical fiber should be no less than
40 mm.
l Do not bundle optical fibers too tight. Otherwise, optical fiber performance may be degraded,
affecting communications between devices.
Procedure
Step 1 Gently push an optical module into an optical interface until you hear a click.
NOTE
If the optical module cannot be completely inserted into the optical interface, do not force it into the
interface. Turn the optical module 180 degrees over and try again.
Issue 08 (2015-05-08)
212
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Place the dust plug in an appropriate place. After optical fibers are removed from the optical module, cover
the optical module with the dust plug to protect it from dust.
Step 3 Before connecting optical fibers, attach temporary labels on both ends of each optical fiber to
identify them. For details on how to make labels of optical fibers, see 14.5.2 Engineering Labels
for Optical Fibers.
Step 4 Remove the dust caps from the fiber connectors. Connect one end of the optical fiber to the
optical module and the other end to the remote device.
NOTE
Connect the receive and transmit ends of the fiber connector according to the identifiers on receive and
transmit bores of the optical module. Do not connect the two ends reversely.
GE1
AR2200 Series
ON
STATUS
STATUS
OFF
~100-240V;50/60Hz;5A
PWR350A
10PWR 9PWR
11 SRU
12
F
A
N
GE1
SYS ACT
LINK0 LINK1
micro SD
ACT
SRU40
EN
ACT0 ACT1
GE0
GE1
GE2
EN
CON/AUX
RST
FAN
Optical fiber
Optical interface of
the remote device
Issue 08 (2015-05-08)
213
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Step 5 Arrange the optical fibers to make them parallel and bundle them with fiber binding tape at an
interval of 150 mm to 300 mm.
Step 6 Replace all the temporary labels with formal labels on the optical fibers.
----End
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on a router before you finish connecting power cables and network cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
The AC power cable parameters vary in different countries or regions. The figures in this section are for
reference only and may differ from the cables delivered.
AC Power Cable
Procedure
Step 1 Verify that the router is reliably grounded.
Step 2 Set the power switch to OFF.
Step 3 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 4 Connect the AC power cable.
1.
Connect the one end of the AC power cable to the power socket on the AC power module.
2.
Issue 08 (2015-05-08)
214
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
AC Power Cable
AC power outlet
AR2200 Series
ON
STATUS
STATUS
OFF
~100-240V;50/60Hz;5A
PWR350A
10PWR 9PWR
11 SRU
12
F
A
N
GE1
SYS ACT
LINK0 LINK1
micro SD
ACT
SRU40
EN
ACT0 ACT1
GE0
GE1
EN
GE2
CON/AUX
RST
FAN
Insert the AC terminal locking latch into the jack beside the power socket.
2.
3.
Issue 08 (2015-05-08)
215
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
ON
OFF
0Hz;5A
~100-24
0V;50/6
~100-24
0V;50/6
ON
OFF
0Hz;5A
ON
OFF
~100-24
5A
0Hz;
0V;50/6
----End
Follow-up Procedure
Perform the following operations after connecting the AC power cable:
l
Verify that the AC power cable is securely connected to the power socket on the router.
If multiple routers are installed, attach labels to both ends of each power cable and write
numbers on the labels to identify them.
Issue 08 (2015-05-08)
216
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Context
DANGER
To avoid electric shock, do not connect power cables while the power is on.
NOTICE
l Do not power on a router before you finish connecting power cables and network cables.
l Each router has its own power cables delivered as accessories. The power cables can only
be used on the router in the same package and cannot be used on any other device.
NOTE
The DC power cable parameters vary in different countries or regions. The figures in this section are for
reference only and may differ from the cables delivered.
DC power cables
Procedure
Step 1 Verify that the router is reliably grounded.
Step 2 Set the power switch to OFF.
Step 3 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 4 Install cord end terminals or OT bare crimp terminals on the DC power cables.
NOTE
The cord end terminals and OT bare crimp terminals are delivered in the installation accessory package.
When using a DC power module in the router, select the terminals as required.
If the DC power supply system for the router requires cord end terminals, assemble the DC
power cables by referring to Figure 11-11.
Figure 11-11 Installing a cord end terminal
1
L1
Issue 08 (2015-05-08)
217
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
If the DC power supply system for the router requires OT bare crimp terminals, assemble
the DC power cables by referring to Figure 11-12.
Figure 11-12 Installing an OT bare crimp terminal
1
L2
L1
Insert the one end of the DC power cables to the DC power terminals on the DC power
module.
2.
Connect the other end of the power cables to output terminals of the external DC power
supply system.
AR2200 Series
STATUS
PWR
OFF
NEG(-)
RTN(+)
STATUS
10PWR 9PWR
11 SRU
ON
PWR350D
12
F
A
N
-48 -60V;9.6A
GE1
SYS ACT
LINK0 LINK1
micro SD
ACT
SRU40
EN
ACT0 ACT1
GE0
GE1
GE2
EN
CON/AUX
RST
FAN
NEG(-) RTN(+)
DC power cable
----End
Follow-up Procedure
Perform the following operations after connecting the DC power cables:
l
Verify that DC power cables are securely connected to the power terminals.
If multiple routers are installed, attach labels to both ends of each power cable and write
numbers on the labels to identify them.
218
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Procedure
Turn on the power switch of the power supply system, and then turn on the power switch
on the router to start the router.
After the router starts, check the STATUS indicator of the power module first. If this
indicator is in normal state, check the other indicators of the router. Figure 11-13 describes
the indicator states when the router is running normally.
Figure 11-13 Normal indicator states on the router
STATUS
STATUS
AR2200 Series
ON
STATUS
STATUS
OFF
~100-240V;50/60Hz;5A
PWR350A
SYS ACT
SYS ACT
12
F
A
N
GE1
LINK0 LINK1
micro SD
ACT
SRU40
10PWR 9PWR
11 SRU
EN
ACT0 ACT1
GE0
GE1
GE2
EN
CON/AUX
RST
FAN
Hardware Module
Indicator
Description
Power module
STATUS
MPU
SYS
Fan module
STATUS
NOTICE
l Powering off the router will interrupt all the services on the router. Exercise caution
when you perform this operation.
l Do not power off or restart the AR3670 router when it is performing read-write operating
on the SATA hard disk.
Issue 08 (2015-05-08)
219
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Turn off the power switch on the router, and then turn off the power switch of the power
supply system.
----End
Follow-up Procedure
After the router starts, you can log in to its CLI to configure, manage, and maintain the router.
For details, see the CLI-based Configuration.
Issue 08 (2015-05-08)
220
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12
12 Maintaining a Router
Maintaining a Router
Issue 08 (2015-05-08)
221
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
NOTICE
l Replacing a card interrupts services. Therefore, save the configurations before replacing the
card.
l To avoid damages to the card, do not touch the electronic components on the card during the
replacement.
l Unused cards or parts must be placed in ESD bags. Do not pack cards with common foam
materials, plastic bags, paper bags, or other packing materials without the ESD prevention
function.
l Vacant slots in the router must be covered with filler panels.
NOTE
The methods for replacing SIC, WSIC, XSIC, and SRU cards on routers are the same. The following
procedure replaces a SIC card on an AR2240 router.
Tools
l
Phillips screwdriver
ESD bag
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Remove cables from the card to be replaced, and record mappings between cables and interfaces
on the card to ensure correct cable connections on the new card.
Step 3 Remove the old card.
1.
Loosen the captive screws on both sides of the card and rotate the ejector levers outward.
2.
Lowly pull the card out of the slot along the guide rails.
Issue 08 (2015-05-08)
222
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
Do not touch the other power module with your body or any tool to avoid electric shocks.
Issue 08 (2015-05-08)
223
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
NOTICE
l AC and DC power modules cannot be used together in the same router.
l Before replacing a power module, turn off its power switch.
l A power module can be hot swapped.
l Vacant slots in the router must be covered with filler panels.
NOTE
The procedures for replacing a power module in different routers are the same. The following procedure
replaces an AC power module in an AR2240 router.
Tools
l
Phillips screwdriver
Procedure
Step 1 Confirm the power module that needs to be replaced.
Before replacing a power module, determine in which cabinet and chassis the power module is
installed, find the power module in the chassis, and attach a label on the panel of the power
module.
Step 2 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 3 Turn the power switch on the power module to the OFF position.
Step 4 Remove the power cable from the power module.
The procedure for removing a power cable is opposite to the procedure for installing the power
cable. For details, see 11.5.5 Connecting the AC Power Cable.
Step 5 Remove the power module.
1.
Use a Phillips screwdriver to loosen the captive screws on the power module.
2.
Rotate the ejector levers outward to release the power cable from the slot.
3.
Lowly pull the power module out of the slot along the guide rails.
Issue 08 (2015-05-08)
224
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
a
b
s
AR2200 Serie
STATUS
ON
OFF
Hz;5A
50/60
~100ON240V;
GE1
50/60Hz;5A
~100-240V;
OFF
EN
GE1
ACT0 ACT1
ro SD
micro
m
SYS ACT
RST
EN
CON/AUX
LINK00 LINK1
GE2
GE0
ACT
Step 6 Install a new power module into the router. For details, see 11.3 Installing a Power Module.
Step 7 Connect the power cable to the power module.
l
For details on how to connect the AC power cable, see 11.5.5 Connecting the AC Power
Cable.
For details on how to connect the DC power cables, see 11.5.6 Connecting DC Power
Cables.
Step 8 Turn the power switch on the power module to the ON position.
Step 9 Use either of the following methods to check whether the new power module works normally:
l Check the indicator on the new power module. If the indicator is steady green, the power
module is working normally.
l Run the display device command to check the running status of the new power module.
----End
NOTICE
Fan modules are hot swappable. When replacing a fan module, insert the new fan module within
1 minute.
NOTE
The procedures for replacing a fan module in different routers are the same. The following procedure
replaces a fan module in an AR2240 router.
Issue 08 (2015-05-08)
225
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
Tools
l
Phillips screwdriver
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Remove the old fan module.
1.
Use a Phillips screwdriver to loosen the captive screws on the fan module.
2.
Grasp the handle of the fan module and pull out a part of the fan module. Wait until the
fans stop running, and then pull the fan module completely out of the chassis.
b
AR2200 Series
ON
STATUS
OFF
~100-240V;50
/60Hz;5A
GE1
EN
CON/AUX
LINK0 LINK1
GE1
GE2
GE0
ACT0 ACT1
micro SD
RST
EN
ACT
SYS ACT
Hold the handle of the fan module with one hand and support the bottom with the other
hand. Slowly push the fan module into the slot along the guide rails, until the fan module
is completely attached to the backplane.
2.
Use the Phillips screwdriver to tighten the captive screws on the fan module.
a
AR2200 Series
ON
STATUS
OFF
~100-240V;50
GE1
EN
GE1
ACT0 ACT1
RST
EN
CON/AUX
LINK0 LINK1
micro SD
SYS ACT
/60Hz;5A
GE2
GE0
ACT
----End
Issue 08 (2015-05-08)
226
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
Context
DANGER
Invisible laser beams will cause eye damage. When replacing optical modules, do not look into
bores of optical modules or connectors of optical fibers without eye protection.
NOTICE
l A router must use Huawei-certified optical modules. Non-Huawei-certified optical modules
cannot ensure transmission reliability and may affect service stability. Huawei is not
responsible for any problem caused by the use of non-Huawei-certified optical modules and
will not fix such problems.
l Replacing an optical module interrupts service transmission on the corresponding interface.
Therefore, replace an optical module only when you confirm that the optical module has
failed.
l Optical modules are hot swappable, and you do not need to power off the switch when
replacing optical modules.
l Do not insert an optical module reversely. If an optical module cannot be completely inserted
into an optical interface, do not force it into the interface. Turn the optical module over and
try again.
l Install or remove optical fibers carefully to avoid damages to fiber connectors.
l After removing the optical fibers from an optical module, cover the fiber connectors with
dust caps. Place the optical fibers in an appropriate place to prevent them from swinging.
Tools
l
Dust caps
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Remove the optical fibers on the optical module.
Mark the positions of the Tx and Rx optical fibers on the bores of the optical module, and then
remove the optical fibers.
Step 3 Cover the removed optical fibers with dust caps.
Step 4 Remove the optical module.
Issue 08 (2015-05-08)
227
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
1.
2.
Pull the handle of the optical module and press the router panel with your thumb to remove
the optical module.
Step 5 Insert a new optical module into the optical interface until the optical module is secured in the
optical interface.
Step 6 Connect the Tx and Rx optical fibers to the marked positions.
Step 7 Check the LINK indicator on the optical interface. If the LINK indicator turns green, the new
optical module works normally.
----End
NOTICE
l A router must use a Huawei-certified SIM card. Non-Huawei-certified SIM card cannot
ensure reliability and may affect service stability. Huawei is not responsible for any problem
caused by the use of non-Huawei-certified SIM cards and will not fix such problems.
l A SIM card is not hot swappable.
Table 12-1 lists the cards that support SIM card replacement.
Issue 08 (2015-05-08)
228
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
3G-HSPA+7
Supported
3G-EVDO
1LTE-H
Supported
1LTE-L
1LTEC
Tools
l
Phillips screwdriver
Procedure
Step 1 Wear an ESD wrist strap. Ensure that the ESD wrist strap is grounded and in a close contact
with your wrist.
Step 2 Turn off the power switch on the router.
Step 3 Remove the card with the SIM card to be replaced from the router.
Step 4 Loosen the screw on the SIM card holder.
LO
PE
N
CK
Step 5 Slide the SIM card holder horizontally towards the direction specified by the OPEN arrow and
open the SIM card holder.
Issue 08 (2015-05-08)
229
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
Issue 08 (2015-05-08)
230
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
12 Maintaining a Router
Step 8 Slide the SIM card holder towards the direction specified by the LOCK arrow, close the SIM
card holder, and tighten the screw.
LO
PE
N
CK
----End
Issue 08 (2015-05-08)
231
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
13
13 Hardware Troubleshooting
Hardware Troubleshooting
Issue 08 (2015-05-08)
232
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
13 Hardware Troubleshooting
Possible Causes
l
Troubleshooting Procedure
1.
2.
3.
4.
If the router still cannot be powered on, the router itself is faulty. Contact Huawei technical
support or Huawei agent through Ask for Help and ask them to replace the router.
Possible Causes
l
Issue 08 (2015-05-08)
233
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
13 Hardware Troubleshooting
Troubleshooting Procedure
1.
2.
3.
Possible Causes
l
One or more fans stop running because the blades are blocked.
Troubleshooting Procedure
1.
Reinstall the fan module to make sure that it is securely connected to the backplane, and
then fasten the captive screws on the fan module panel.
2.
If there are obstacles blocking fan blades, remove the fan module, clear the fans, and install
the fan module in the chassis.
NOTE
A fan module usually has more than one fan. If any fan fails to run, all the other fans run at the full
speed, causing loud noises.
3.
Check whether the fan module is running the latest software version. Contact Huawei
technical support through Ask for Help to know the latest software version for fan modules.
If the fan module is not running the latest software version, upgrade the software version.
Software version 103 is used as an example here.
a.
Run the display fan command to check the status of the fan module. The following
information indicates that the fan module is not working normally.
<Huawei> display fan
FanId
FanNum
Present
16
[1-3]
YES
Register
YES
Speed
NA
Mode
MANUAL
The following information will be displayed if the fan module is working normally:
<Huawei> display fan
FanId
FanNum
Present
16
[1-3]
YES
1
2
3
Issue 08 (2015-05-08)
Register
YES
Speed
49%
2670
2640
2640
Mode
MANUAL
234
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
13 Hardware Troubleshooting
NOTE
If the fan module creates loud noises but the display fan command output shows that the fan
speed is 100%, the fan module is working normally. It may be the high ambient temperature
that causes the fans to run at full speed.
b.
If the speed field in the display fan command output displays NA, the fans are not
running normally. Reinstall the fan module, and then run the display version slot
fan command to check the software version of the fan module.
<Huawei> display version slot fan
FAN version information:
1. PCB
Version : AR01DF05A VER.A
2. Board
Type
: FAN
3. Software Version : 103
Software version 103 is not the latest version and needs to be upgraded.
c.
Contact Huawei technical support through Ask for Help to obtain the latest fan
software version.
d.
See Transferring Files Using FTP/TFTP to load the fan software version to SD1 of
the router.
e.
Run the upgrade fan-software command to upgrade the fan software version.
<Huawei> system-view
Enter system view, return user view with Ctrl
+Z
[Huawei] diagnose
Now you enter a diagnostic command view for developer's testing,some
commands
may affect operation by wrong use,please carefully use it with HUAWEI
engineer's direction
[Huawei-diagnose] upgrade fan-software sd1:/
arfan_soc_V108.iap
Info: Now Loading the upgrade file to fan-board, please wait a
moment
Info: Upgrade the fan-board successfully.The new version is 108, while the
old version is 103
NOTE
f.
If the fan module is removed during the upgrade or the upgrade fails, the following
information is displayed:
[Huawei-diagnose] upgrade fan-software sd1:/
arfan_soc107.iap
Info: Now Loading the upgrade file to fan-board, please wait a
moment
Load app get response fail! Index =
0xaa
Load Tx fail!
Error: Load the upgrade file to fan-board fail
When this occurs, reinstall the fan module, and repeat step e to perform the upgrade
again.
NOTE
The new fan software takes effect after the upgrade succeeds, without a need to restart the
router.
4.
Issue 08 (2015-05-08)
If the problem persists, install another fan module of the same model into the fan slot. If
the new fan module can work normally, the original fan module has failed.
235
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
13 Hardware Troubleshooting
NOTICE
Before replacing the fan module, power off the router.
Possible Causes
l
Troubleshooting Procedure
1.
2.
3.
Issue 08 (2015-05-08)
Contact Huawei technical support through Ask for Help and confirm whether this software
version supports the card.
236
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
13 Hardware Troubleshooting
If a card registers successfully, the Register field in the display device command output
displays Registered.
<Huawei> display device
AR3260's Device status:
Slot
Sub Type
Online
5
8FE1GE
Present
Power
PowerOn
Register
Registered
Alarm
Normal
Primary
NA
Power
PowerOn
Register
Unregistered
Alarm
NA
Primary
NA
Possible Causes
l
The card was removed and reinstalled before the upgrade but was not securely connected
to the backplane.
The card software is upgraded after the system software is upgraded. During the card
software upgrade, the router is powered off, causing an upgrade failure.
Troubleshooting Procedure
1.
Remove the card and check whether any pins on the backplane connector are bent. Ensure
that the card can be securely connected to the backplane.
NOTE
2.
Contact Huawei technical support through Ask for Help and restore the card software under
their help.
NOTE
A card software upgrade takes about 8 minutes. Ensure that the router is not powered off during the
upgrade.
Possible Causes
l
Issue 08 (2015-05-08)
237
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
13 Hardware Troubleshooting
Troubleshooting Procedure
1.
Turn off the power switch on the router, reinstall the power cable and power module
properly, and turn on the power switch.
2.
3.
Check whether the input voltage is stable. If lights in the equipment room flicker, use a
voltage regulator to maintain the voltage or power the router with an uninterruptible power
supply.
4.
Connect the ground point on the router to an indoor equipotential terminal to mitigate the
risks of unexpected resets caused by lightning.
Possible Causes
l
Troubleshooting Procedure
1.
2.
NOTICE
Use a Huawei-certified SD card or USB flash drive.
If the system still fails to write data to the Huawei-certified SD card or USB flash drive, contact
Huawei technical support through Ask for Help.
Issue 08 (2015-05-08)
238
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
14
Appendix
Issue 08 (2015-05-08)
239
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Silkscreen
Color
Description
On the chassis
SYS
On the SRU
SYS
ACT: (active/
standby status
indicator)
Green
Issue 08 (2015-05-08)
240
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Color
Description
STATUS
Color
Description
STATUS
Color
Description
STAT
Green
Issue 08 (2015-05-08)
Red
Off
241
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Color
Description
EN (CON/AUX
port)
Green
If the jacket or insulation of a cable has visible damage, irreparable scuffing, or other
defects, do not use the cable.
If the cable jacket or insulation cracks after the cable is bent or twisted, discard this cable
and check whether other cables have the same problem. If other cables have the same
problem, replace these cables.
Do not use connectors if their shells or pins have exposed part or uneven plating, or their
pins are lost, broken, or bent.
Do not use connectors that have dirt on their pins or in their jacks or if there are conductors
between pins or between pins and the shell.
Use dedicated tools or tools delivered by Huawei and follow the methods given here during
assembly.
Hold terminals of cables instead of pulling the cables themselves when installing or
removing cable components.
Issue 08 (2015-05-08)
242
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Coil cables longer than 2 m (6.56 ft) after cutting. Bind and fasten the coils using
bundling ropes. The inner diameters of the coils should be larger than 20 times the outer
diameters of the cables.
When stripping the jackets of cables, avoid damaging the shield layers (braid or
aluminum foil), insulation, core conductors, and other jackets that do not need to be
stripped.
After assembling cables, cut all visible cross sections of jackets to ensure that the cross
sections are arranged neatly.
Do not touch the core conductors of cables with your hands. Terminate exposed
conductors in a timely way after stripping off insulation so that the surface of the
conductors does not become oxidized.
l
Take the following precautions when crimping and connecting cables or connectors:
The terminals and conductors should be connected tightly after they are crimped. They
should not be moved or turned.
Cut all the exposed copper wires.
Try to avoid a second crimping of sleeves.
Keep all the conductors clean and aligned.
NOTE
The connectors, cables, and tools provided by different vendors may be different. The figures in this
document are for your reference only.
A. Heat-shrinkable tubing
Issue 08 (2015-05-08)
C. Insulation
D. Conductor
243
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Procedure
Step 1 Based on the cross-sectional area of the cable conductor, strip a length of insulation coating C
to expose the conductor D of length L1, as shown in Figure 14-2. The recommended values of
L1 are listed in Table 14-6.
Figure 14-2 Stripping a power cable (OT terminal)
NOTICE
l When you strip a power cable, do not damage the conductor of the cable.
l If the bare crimping terminal is not provided by Huawei, the value of L1 is 1 mm (0.04 in.)
to 2 mm (0.08 in.) greater than the value of L.
Table 14-6 Mapping between the cross-sectional area of the conductor and the value of L1
Issue 08 (2015-05-08)
CrossSectional Area
of Conductor
(mm2(in.2))
Value of L1 (mm
(in.))
Cross-Sectional
Area of Conductor
(mm2(in.2))
Value of L1 (mm
(in.))
1 (0.002)
7 (0.28)
10 (0.015)
11 (0.43)
1.5 (0.002)
7 (0.28)
16 (0.025)
13 (0.51)
2.5 (0.004)
7 (0.28)
25 (0.039)
14 (0.55)
4 (0.006)
8 (0.31)
35 (0.054)
16 (0.63)
6 (0.009)
9 (0.35)
50 (0.077)
16 (0.63)
244
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
NOTE
If you are proficient in assembling OT terminals and power cables, you can obtain the value of L1 by
comparing the part to be crimped with the power cable.
Step 2 Put the heat-shrinkable (A) tubing onto the bare crimping terminal, as shown in Figure 14-3.
Figure 14-3 Putting the heat shrink tubing onto the bare crimping terminal
Step 3 Put the OT terminal B onto the exposed conductor, and ensure that the OT terminal is in good
contact with the insulation coating C, as shown in Figure 14-3.
NOTICE
After the conductor is fed into the OT terminal, the protruding part of the conductor, or L2 in
Figure 14-3, must not be longer than 2 mm (0.08 in.).
Step 4 Crimp the joint parts of the bare crimping terminal and the conductor, as shown in Figure
14-4.
NOTE
The shapes of crimped parts may vary with the crimping dies.
Issue 08 (2015-05-08)
245
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Figure 14-4 Crimping the joint parts of the bare crimping terminal and the conductor (OT
terminal)
Step 5 Push the heat shrink tubing (A) toward the connector until the tube covers the crimped part, and
then use a heat gun to heat the tube, as shown in Figure 14-5.
Figure 14-5 Heating the heat shrink tubing (OT terminal)
NOTICE
Stop heating the shrink tubing when the connector is securely locked in the shrink tubing. Do
not heat the shrink tubing too long as this may damage the insulation coating.
----End
Issue 08 (2015-05-08)
246
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Context
Figure 14-6 shows the components of a JG terminal and a power cable.
Figure 14-6 Components of a JG terminal and a power cable
A. JG terminal B. Heat-shrinkable tubing C. Insulation layer of a power cable D. Conductor of a power cable
Procedure
Step 1 Strip a part of the insulation to expose the cable conductor with a length of L, as shown in Figure
14-7. The recommended values of L are listed in Table 14-7.
NOTICE
l When you strip a power cable, do not damage the conductor of the cable.
l If the bare crimping terminal is not provided by Huawei, you can adjust the value of L as
required.
Issue 08 (2015-05-08)
247
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Table 14-7 Mapping between the cross-sectional area of the conductor and the value of L
Cross-Sectional Area of Conductor
(mm2(in.2))
Value of L (mm(in.))
16 (0.025)
13 (0.51)
25 (0.039)
14 (0.55)
35 (0.054)
16 (0.63)
50 (0.077)
16 (0.63)
Step 2 Put the heat shrink tubing onto the bare crimping terminal, as shown in Figure 14-8.
Figure 14-8 Putting the heat shrink tubing onto the bare crimping terminal
Step 3 Put the bare crimping terminal onto the exposed conductor, and ensure that the bare crimping
terminal is in good contact with the insulation of the power cable, as shown in Figure 14-8.
Step 4 Crimp the joint parts of the bare crimping terminal and the conductor, as shown in Figure
14-9.
Figure 14-9 Crimping the joint parts of the bare crimping terminal and the conductor (JG
terminal)
Issue 08 (2015-05-08)
248
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 5 Push the heat shrink tubing toward the connector until the tube covers the crimped part, and then
use a heat gun to heat the tube, as shown in Figure 14-10.
Figure 14-10 Heating the heat shrink tubing (JG terminal)
----End
Procedure
Step 1 Strip a part of the insulation to expose the cable conductor with a length of L1, as shown in
Figure 14-12. The recommended values of L1 are listed in Table 14-8.
Issue 08 (2015-05-08)
249
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
NOTICE
When you strip a power cable, do not damage the conductor of the cable.
Table 14-8 Mapping between the cross-sectional area of the conductor and the value of L1
CrossSectional Area
of Conductor
(mm2(in.2))
Value of L1 (mm
(in.))
Cross-Sectional
Area of Conductor
(mm2(in.2))
Value of L1 (mm
(in.))
1 (0.002)
8 (0.31)
10 (0.015)
15 (0.59)
1.5 (0.002)
10 (0.39)
16 (0.025)
15 (0.59)
2.5 (0.004)
10 (0.39)
25 (0.039)
18 (0.71)
4 (0.006)
12 (0.47)
35 (0.054)
19 (0.75)
6 (0.009)
14 (0.55)
50 (0.077)
26 (1.02)
Step 2 Put the cord end terminal onto the conductor, and ensure that the conductor is aligned with the
edge of the cord end terminal, as shown in Figure 14-13.
NOTICE
After the conductor is fed into the cord end terminal, the protruding part of the conductor must
not be longer than 1 mm (0.04 in.).
Issue 08 (2015-05-08)
250
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Figure 14-13 Putting the cord end terminal onto the conductor
Step 3 Crimp the joint parts of the cord end terminal and the conductor, as shown in Figure 14-14.
Figure 14-14 Crimping the cord end terminal and the conductor
Step 4 Check the maximum width of the tubular crimped terminal. The maximum width of a tubular
crimped terminal is listed in Table 14-9.
Table 14-9 Maximum width of a tubular crimped terminal
Issue 08 (2015-05-08)
0.25 (0.0004)
1 (0.04)
0.5 (0.0008)
1 (0.04)
1.0 (0.0015)
1.5 (0.06)
1.5 (0.0023)
1.5 (0.06)
2.5 (0.0039)
2.4 (0.09)
4 (0.006)
3.1 (0.12)
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
251
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
6 (0.009)
4 (0.16)
10 (0.015)
5.3 (0.21)
16 (0.025)
6 (0.24)
25 (0.039)
8.7 (0.34)
35 (0.054)
10 (0.39)
----End
A. Jacket of connector
Procedure
Step 1 Fit the jacket of the connector onto the Ethernet cable, as shown in Figure 14-16.
Issue 08 (2015-05-08)
252
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Figure 14-16 Fitting the jacket of the connector onto the Ethernet cable
Step 2 Remove a 30 mm (1.18 in.) long section of the jacket, cut off the nylon twine inside the jacket,
and cut a no more than 5 mm (0.20 in.) cleft in the jacket, as shown in Figure 14-17.
NOTICE
l When you remove a section of the jacket, do not damage the shield layer of the twisted-pair
cable.
l When you remove the shield layer, do not damage the insulation of the twisted-pair cable.
Step 3 Fit the metal shell onto the twisted-pair cable. The shield layer is covered by the metal shell, as
shown in Figure 14-18.
Issue 08 (2015-05-08)
253
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Figure 14-18 Fitting the metal shell onto the twisted-pair cable
Step 4 Fit the metal shell onto the twisted-pair cable until the shield layer is covered completely. Along
the edge of the metal shell, cut off the aluminum foil shield layer and ensure that there is no
surplus copper wire. The exposed twisted-pair cable is about 20 mm (0.79 in.) long, as shown
in Figure 14-19.
Figure 14-19 Removing the shield layer of a twisted-pair cable (unit: mm (in.))
Step 5 Lead the four pairs of twisted-pair wires through the wire holder, as shown in Figure 14-20 and
Figure 14-21. Ensure that the colored wires are in the correct location in the cable.
Figure 14-20 Leading wires through the wire holder
G C
Issue 08 (2015-05-08)
254
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
White-Orange
Orange
White-Green
Green
Blue
White-Blue
White-Brown
Brown
Step 6 Align the four pairs of cables in the holder, as shown in Figure 14-22. The connections between
the wires and the pins are shown in Figure 14-23 and listed in Table 14-10.
Figure 14-22 Four pairs of cables on a wire holder
Issue 08 (2015-05-08)
255
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Pin 8
Pin 1
Table 14-10 Connections between wires and pins (using a straight-through cable as an example)
Matching Pins of Wires
Wire Color
White-Orange
Orange
White-Green
Blue
White-Blue
Green
White-Brown
Brown
Step 7 Cut off the surplus cables along the lower edge of the wire holder, as shown in Figure 14-24.
Issue 08 (2015-05-08)
256
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 8 Put the connector body onto the wire holder and turn the metal shell by 90, as shown in Figure
14-25.
NOTE
Ensure that the wire holder is in good contact with the connector body.
Figure 14-25 Putting the connector body onto the wire holder
Step 9 Push the metal shell toward the connector body until the wire holder and the connector body are
engaged completely. Crimp the connector, as shown in Figure 14-26.
Figure 14-26 Crimping the connector
Issue 08 (2015-05-08)
257
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 10 Push the jacket towards the metal shell until the metal shell is covered. This completes the
assembly of one end of the cable, as shown in Figure 14-27.
Figure 14-27 Pushing the metal shell
Step 11 To complete the assembly of the other end, repeat Step 1 through Step 10.
----End
B
C
A. Plug of connector
Issue 08 (2015-05-08)
B. Jacket
C. Twisted-pair wires
258
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Procedure
Step 1 Remove a 16-mm (0.63 in.) long section of the jacket, as shown in Figure 14-29.
NOTICE
When you remove the shield layer, do not damage the insulation of the twisted-pair cable.
Step 2 Align the four pairs of wires and cut the ends neatly, as shown in Figure 14-30. The connections
between the wires and the pins are listed in Table 14-11.
Figure 14-30 Connections between wires and pins (unit: mm (in.))
C
White-Orange
Orange
White-Green
Blue
White-Blue
Green
White-Brown
Brown
Pin 8
Pin 1
16
Table 14-11 Connections between wires and pins (using a straight-through cable as an example)
Issue 08 (2015-05-08)
Wire Color
White-Orange
Orange
White-Green
Blue
White-Blue
Green
White-Brown
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
259
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Wire Color
Brown
Step 3 Feed the cable into the plug, and crimp the connector, as shown in Figure 14-31.
NOTE
When inserting the cable, check from the side or bore of the plug to ensure that the cable is completely
seated in the plug.
Step 4 To complete the assembly of the other end, repeat Step 1 through Step 3.
----End
To ensure proper contact between the crimped wires and the wire conductors, the heights
and sizes of the contact strips must be standard and the same.
The contact strips must be parallel to each other, with an offset of less than 5. The top
margin of a strip must be parallel to the axis of the connector, with an offset of less than
10.
The contact strips must be in good contact with the RJ45 socket. The plastic separators
must remain intact and be aligned.
The contact strip blade must extend beyond the ends of the wires. The ends of the wires
must be in contact with the edge of the RJ45. The distance between them must be less than
0.5 mm (0.02 in.).
Procedure
Step 1 Hold the crimped connector, with the front side facing you, and check whether the contact strips
are of the same height. The height should be 6.02 0.13 mm (0.237 0.005). If a measuring
tool is not available, you can compare the connector with a standard connector. Figure 14-32
shows an unqualified piece, and Figure 14-33 shows a qualified piece.
Issue 08 (2015-05-08)
260
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
NOTE
Step 2 Hold an RJ45 connector and turn it 45. Observe the top edges of the metal contact strips. Figure
14-34 shows an unqualified piece.
Figure 14-34 Unparallel contact strips of different heights
Issue 08 (2015-05-08)
261
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 3 Check whether the contact strips are clean. If they are not clean and the dirt cannot be removed,
replace it with a new RJ45 connector. Figure 14-35 shows an unqualified piece.
Figure 14-35 Dirt on a contract strip
Step 4 Check whether the contact strips and the plastic separators are well aligned and intact. If a
separator is skewed and cannot be fixed, replace it with a new RJ45 connector. Figure 14-36
shows an unqualified piece.
Figure 14-36 Skewed plastic separators
Step 5 Hold the connector with the side facing towards you, and check whether you can see the crosssections of the wires. Ensure that the ends of the wires are in good contact with the edge of the
RJ45, and that the contact strip blade extends beyond the ends of the wires and is crimped with
the wires. If not, replace the connector. Figure 14-37 shows an unqualified piece.
Figure 14-37 Wires not in good contact with the edge of the RJ45
Issue 08 (2015-05-08)
262
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
----End
Straight-through cables are connected in a one-to-one manner. They are used to connect
terminals such as a computer or switch to network devices. Table 14-12 lists the
connections of core wires in a straight-through cable.
Table 14-12 Connections of core wires in a straight-through cable
RJ45 Connector 1
RJ45 Connector 2
Twisted or Not
Orange
Twisted
Orange-White
Green
Green-White
Blue
Blue-White
Brown
Brown-White
Twisted
Twisted
Twisted
Crossover cables are connected in a crossover manner. They are used to connect terminals
such as two computers or switches. Table 14-13 lists the connections of core wires in a
crossover cable.
Table 14-13 Connections of core wires in a straight crossover cable
Issue 08 (2015-05-08)
RJ45 Connector 1
RJ45 Connector 2
Twisted or Not
Orange
Twisted
Orange-White
Green
Green-White
Blue
Blue-White
Brown
Twisted
Twisted
Twisted
263
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
RJ45 Connector 1
RJ45 Connector 2
Brown-White
Twisted or Not
Pin8
Pin1
Procedure
Step 1 Feed both connectors of the cable into the ports of the cable tester.
Step 2 After the connectors are properly inserted, turn on the tester. If the indicators from 1 to G turn
on simultaneously, you can infer that the pins work normally and the wires are correctly
connected.
NOTE
Turn the switch to the S position to slow down lighting of the indicators so that you can see the indicators
more clearly, as shown in Figure 14-39.
Issue 08 (2015-05-08)
264
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 3 Gently shake the connector and repeat Step 2 to check whether the metal contact strips are in
good contact with the core wires and Ethernet ports, as shown in Figure 14-40.
Figure 14-40 Checking the reliability
The procedure for testing a crossover cable is the same as that for testing a straight-through cable
except for the sequence in which the indicators turn on, which depends on the wire connections
of a crossover cable.
The Ethernet cable is qualified if the indicators turn on in the following sequence:
At the master (left) section of the tester, the indicators turn on in the sequence of 1-8-G. At the
slave (right) section of the tester, the indicators turn on in the sequence of 3-6-1-4-5-2-7-8-G.
If the indicators do not come on in this sequence, the Ethernet cable is unqualified.
NOTE
If a tester is not available, you can use a multimeter to perform a simple test, as shown in Figure 14-41.
Issue 08 (2015-05-08)
265
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
----End
The illustrations in this document may differ from actual situations, but the installation methods are the
same. For example, in this document, the adapters of cable connectors have separate interfaces. In the actual
situation, the adapters may have interfaces fixed on equipment.
Use dedicated tools provided or specified by Huawei and follow the installation procedure
described here.
Bending Radius
Unless otherwise specified, bending radius (R) of cables or fibers must meet the requirements
listed in Table 14-14.
Table 14-14 Bending radius of cables or fibers
Cable or Fiber
Ordinary cable
Fiber
NOTE
Hold terminals of cables instead of pulling the cables themselves when installing or
removing cable components.
Do not insert a connector forcibly when the connector is blocked. Use a dedicated tool to
pull out the connector. Install the connector again after you check that the pins are inserted
properly.
Before tightening screws on cable connectors, ensure that the connectors are properly
connected to their adapters. Tighten the screw with appropriate force using a flat-head or
Phillips screwdriver instead of bare hands or an electric screwdriver. If the screw cannot
be screwed into the tapped hole, determine the reason and try again. Do not apply too much
force, or the screw or adapter may be damaged.
Issue 08 (2015-05-08)
266
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
When removing densely aligned cables or fiber connectors, use dedicated pliers such as
cable-pulling pliers and fiber-pulling pliers.
Cover the idle fiber connectors with dust caps. Remove the dust caps before using the fiber
connectors.
To protect cables, remove the burrs in the cable through-holes or install protective rings in
the holes.
To ease the connection and to avoid stress, keep cable joints slack. After connecting
multiple cables to a connector that has multiple interfaces, keep the cables slack to avoid
generating stress.
Bind or clean cables gently because cable distortion affects signal quality.
Sharp objects must not touch cable wiring to prevent damage to cables.
To protect power cables, route power cables of the active and standby power modules
separately.
Procedure
l
Install an OT terminal.
1.
Align the hole of the OT terminal (conductor upward) with a connecting hole, as shown
in Figure 14-42.
Figure 14-42 Aligning the OT terminal with a connecting hole
NOTE
When you install an OT terminal, the crimping sleeve is installed as shown in Figure 14-43,
where A is correct and B is incorrect.
Issue 08 (2015-05-08)
267
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
2.
Place the spring washer and flat washer in turn, mount a matching screw, and fasten
it clockwise, as shown in Figure 14-44.
Figure 14-44 Installing two terminals back to back
NOTICE
Ensure that the OT terminal is not in contact with other terminals or metal components.
3.
Issue 08 (2015-05-08)
Move the cable slightly and ensure that it is securely connected, as shown in Figure
14-45.
268
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Issue 08 (2015-05-08)
269
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
NOTICE
If the two terminals are different sizes, place the smaller one above the bigger one. A
maximum of two terminals can be installed on a post.
l
----End
Procedure
Step 1 Hold a cord end terminal upright and place it on a terminal jack, as shown in Figure 14-48. To
ensure bump contact and dense connection, place the plain side of the terminal outwards.
Figure 14-48 Placing a terminal on a terminal jack vertically
Step 2 Insert the terminal into the jack vertically, and turn the screw clockwise to fasten the terminal,
as shown in Figure 14-49.
Figure 14-49 Feeding the terminal into the jack
Issue 08 (2015-05-08)
270
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
NOTICE
l Ensure that the exposed section of the terminal is less than 2 mm (0.079 in.) in length.
l Do not press the insulation of the terminal.
l Insert only one terminal into one jack.
Step 3 Move the cable slightly and ensure that it is securely connected.
Step 4 Before you remove a cord end terminal, loosen the screw counterclockwise.
----End
Procedure
Step 1 Hold the male and female connectors, with the male connector facing the female connector, as
shown in Figure 14-50.
Figure 14-50 Holding the male and female shielded connectors
Step 2 Insert the male connector into the female connector, as shown in Figure 14-51.
Issue 08 (2015-05-08)
271
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Figure 14-51 Feeding the male shielded connector into the female shielded connector
Step 3 When you hear a click, the cable connector is completely inserted in the port. (The clip on the
cable connector pops up to fix the connector in the port.) Pull the connector slightly and ensure
that it is securely connected, as shown in Figure 14-52.
Figure 14-52 Installed shielded Ethernet connector
Step 4 To remove an Ethernet connector, press the locking key and pull out the connector, as shown in
Figure 14-53.
Figure 14-53 Removing a shielded Ethernet connector
Issue 08 (2015-05-08)
272
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
----End
Procedure
Step 1 Hold the male and female connectors, with the male connector facing the female connector, as
shown in Figure 14-54.
Figure 14-54 Holding the male and female unshielded connectors
Step 2 Feed the male connector into the female connector, as shown in Figure 14-55.
Figure 14-55 Feeding the male connector into the female unshielded connector
Step 3 A crisp click indicates that the connector is locked by the locking key. Pull the connector slightly
and ensure that it is securely connected. Figure 14-56 shows an installed Ethernet connector.
Issue 08 (2015-05-08)
273
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 4 To remove an Ethernet connector, press the locking key and pull out the connector, as shown in
Figure 14-57.
Figure 14-57 Removing an unshielded Ethernet connector
----End
Issue 08 (2015-05-08)
274
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Context
NOTICE
l After you remove the dustproof cap, ensure that the fiber pins are clean and install them as
soon as possible.
l When you disassemble fiber connectors, you must use a dedicated tool if the connectors are
densely installed.
Procedure
Step 1 Clean the pins of a fiber connector by using lint-free cotton and alcohol.
Step 2 Clean the pins again by using dust-free cotton. If necessary, clean the pins by using an air gun.
Ensure that the pins are free from any fiber or debris.
----End
Procedure
Step 1 Remove the dustproof cap of the FC connector and store it for future use.
Step 2 Align the core pin of the male connector with that of the female connector, as shown in Figure
14-58.
Figure 14-58 Aligning the male connector with the female connector
Step 3 Align the male connector with the female connector and gently push the male connector until it
is completely seated in the female connector, as shown in Figure 14-59.
Issue 08 (2015-05-08)
275
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Figure 14-59 Feeding the male connector into the female connector
Step 4 Fasten the locking nut clockwise and ensure that the connector is securely installed, as shown
in Figure 14-60.
Figure 14-60 Fastening the locking nut
Step 5 To disassemble an FC fiber connector, loosen the locking nut counterclockwise, and gently pull
the male connector, as shown in Figure 14-61.
Issue 08 (2015-05-08)
276
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
----End
Procedure
Step 1 Remove the dustproof cap of the LC fiber connector and store it for future use.
Step 2 Align the core pin of the male connector with that of the female connector, as shown in Figure
14-62.
Figure 14-62 Aligning the male connector with the female connector
Step 3 Align the male connector with the fiber adapter and gently push the male connector until it is
completely seated in the fiber connector, as shown in Figure 14-63.
Issue 08 (2015-05-08)
277
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Figure 14-63 Feeding the male connector into the female connector
Step 4 A clicking sound indicates that the male connector is locked, as shown in Figure 14-64.
Figure 14-64 Installed LC connector
Step 5 To disassemble an LC fiber connector, press the locking nut to release the locking clips from
the bore, and gently pull the male connector, as shown in Figure 14-65.
Figure 14-65 Disassembling an LC fiber connector
Issue 08 (2015-05-08)
278
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
----End
Procedure
Step 1 Remove the dustproof cap of the SC fiber connector and store it for future use.
Step 2 Align the core pin of the male connector with that of the female connector, as shown in Figure
14-66.
Figure 14-66 Aligning the male connector with the female connector
Step 3 Feed the fiber connector into the female connector, with your fingers holding the shell of the
fiber connector (not the pigtail). When you hear a click, the fiber connector is secured by the
clips (internal parts, not illustrated in the figure). Pull the fiber connector gently. If the connector
does not loosen, the installation is complete. See Figure 14-67.
Figure 14-67 Installed SC fiber connector
Issue 08 (2015-05-08)
279
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 4 To disassemble an SC fiber connector, hold the shell of the connector (do not hold the fiber) and
gently pull the connector in the direction vertical to the adapter. Unlock the male connector, and
then separate it from the shell, as shown in Figure 14-68.
Figure 14-68 Disassembling an SC fiber connector
----End
Procedure
Step 1 Remove the dustproof cap of the MPO fiber connector and store it for future use.
Step 2 Align the core pin of the male connector with that of the female connector, as shown in Figure
14-69.
Figure 14-69 Aligning the male connector with the female connector
Issue 08 (2015-05-08)
280
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 3 Hold the shell labeled "PUSH" and feed the male connector into the female connector until you
hear a clicking sound. The male and female connectors are securely installed, as shown in Figure
14-70.
Figure 14-70 Installed MPO fiber connector
Step 4 To disassemble an MPO fiber connector, hold the shell labeled "PULL" and remove the male
connector, as shown in Figure 14-71.
Figure 14-71 Disassembling an MPO fiber connector
----End
281
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 2 Hold the handles of the COAX crimping tools to open the self-locking mechanism. The jaw of
the COAX crimping tools opens automatically, as shown in Figure 14-73.
Figure 14-73 Pliers jaw opening automatically
Step 3 Remove the mold from the COAX crimping tools, as shown in Figure 14-74.
Issue 08 (2015-05-08)
282
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Figure 14-74 Removing the mold from the COAX crimping tools
Step 4 Place the mold to be installed into the jaw of the COAX crimping tools and align the screw holes,
as shown in Figure 14-75.
Figure 14-75 Installing a new mold in the COAX crimping tool
NOTICE
Keep the short side of the mold inwards and the long side outwards, with the teeth of the mold
aligning from the larger size to the smaller size.
Step 5 Hold the handles of the COAX crimping tools tightly to match the mold and the jaw completely.
Align the screw holes, as shown in Figure 14-76.
Issue 08 (2015-05-08)
283
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Step 6 Hold the handles of the COAX crimping tools with one hand. Tighten the two fastening screws
clockwise. Figure 14-77 and Figure 14-78shows the mold installed in the COAX crimping tool.
Figure 14-77 Mold installed in the COAX crimping tool
----End
Issue 08 (2015-05-08)
284
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
The room should be located at a distance of at least 5 km (3.11 mi.) from heavy pollution
sources such as smelting and coal mines. It should be located at a distance of at least 3.7
km (2.30 mi.) from moderate pollution sources such as chemical, rubber, and galvanization
factories. It should be located at a distance of at least 2 km (1.24 mi.) from light pollution
sources such as packinghouses and tanyards. If these pollution sources cannot be avoided,
ensure that the equipment room is upwind of the pollution sources. In addition, use a highquality equipment room or protection products.
The room should be located away from livestock farms, or be upwind of the livestock farms.
Do not use an old livestock room or fertilizer warehouse as the equipment room.
The equipment room must be far away from residential areas. An equipment room that is
not far away from residential areas must comply with equipment room construction
standards to avoid noise pollution.
The room should be located far away from industrial and heating boilers.
The room should be at least 3.7 km (2.30 mi.) away from the seaside or salt lake. Otherwise,
the equipment room should be airtight with cooling facilities. In addition, alkalized soil
cannot be used as the construction material. Otherwise, equipment suitable for wet
conditions must be used.
The doors and windows of the equipment room must be kept closed to maintain an airtight
room.
No cracks or openings are allowed on the walls or floors. The outlet holes on the walls or
windows must be sealed. Walls must be constructed such that they are smooth, wear-
Issue 08 (2015-05-08)
285
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
resistant, dustproof, flame retardant, sound insulated, heat absorptive, and have
electromagnetic shielding.
l
The air vent of the room should be far from the exhaust of city waste pipes, big cesspools
and sewage treatment tanks. The room should be in the positive pressure state to prevent
corrosive gases from entering the equipment room and corroding components and circuit
boards.
It is recommended that the room be on or above the second floor. If this requirement cannot
be met, the ground for equipment installation in the room should be at least 600 mm (23.62
in,) above the maximum flood level.
The equipment room should be strong enough to resist winds and downpours.
The room should be located away from dusty roads or sand. If this is unavoidable, the doors
and windows of the equipment room must not face pollution sources.
Do not place air conditioning vents near the equipment so that they blow directly on the
equipment because condensation may be blown into the equipment.
Do not use decorative materials that contain sulfur in the equipment room.
Transmission
room
Control room
Generator room
Main communication
equipment room
Power distribution
room
Battery room
Substation room
Communication cable and optical cable
Power cable
It should meet requirements for laying out and maintaining communication cables and
power cables.
It should reduce the cabling distance, which facilitates cable maintenance, reduces potential
communication faults, and maximizes efficiency.
Issue 08 (2015-05-08)
286
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Issue 08 (2015-05-08)
Item
Requirements
Area
The smallest area of the equipment room can accommodate the equipment
with the largest capacity.
Net height
The minimum height of the equipment room should not be less than 3 m
(9.84 ft). The minimum height of the equipment room is the net height
below overhead beams or ventilation pipes.
Floor
Load-bearing
capacity
The floor must bear loads larger than 150 kg/m2 (0.21 bf/in.2).
Door and
windows
The door of the equipment room should be 2 m (6.56 ft) high and 1 m (3.28
ft) wide. One door is enough. Seal the doors and windows with dustproof
plastic tape. Use double-pane glass in the windows and seal them tightly.
Wall surface
treatment
Paste wallpaper on the wall or apply flat paint. Do not use pulverized paint.
Cable trays
Use cable trays to arrange cables. The inner faces of the cable trays must
be smooth. The reserved length and width of the cable trays, and the number,
position and dimensions of the holes must comply with the requirements
of device arrangement.
Water pipe
Do not pass service pipes, drainpipes, and storm sewers through the
equipment room. Do not place a fire hydrant in the equipment room, but
place it in the corridor or near the staircase.
Internal
partition wall
Separate the area where the equipment is installed from the equipment room
door. The partition wall can block some outside dust.
Installation
position of the
air conditioner
Install air conditioner vents so that the air does not blow directly on
equipment.
Other
requirements
Avoid the proliferation of mildew, and keep out rodents (like mice).
287
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Unit
Concentration
Dust particle
Particle /m3
3x 104
(no visible dust accumulated
on a workbench in three
days)
Suspending dust
mg/m3
0.2
Precipitable dust
mg/m2h
1.5
Description
l Dust particle diameter 5 m
l Suspending dust diameter 75 m
l 75 m precipitable dust diameter 150 m
288
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Use screens on the door and windows facing outside. The outer windows should be dustproof.
Clean the equipment room regularly and clean the air filter monthly.
Wear shoe covers and ESD clothing before entering the equipment room.
Unit
Concentration
SO2
mg/m3
0.20
H2S
mg/m3
0.006
NH3
mg/m3
0.05
Cl2
mg/m3
0.01
Avoid constructing the room near a place where the corrosive gas concentration is high,
such as a chemical plant.
Ensure the air intake vent of the room is in the prevailing upwind direction from any
pollution source.
Keep the correct humidity level in the equipment room to reduce the impact of static
electricity.
Ground all conductive materials in the room, including computer terminals. Use ESD
worktables.
Keep non-ESD materials (such as common bags, foam, and rubber) at least 30 cm (11.81
in.) away from boards and ESD-sensitive components.
Issue 08 (2015-05-08)
289
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Take effective measures against electrical interference from the power supply system.
Do not use the working ground of the equipment as the same ground for surge protection.
Separate them as far as possible.
Keep the equipment far away from high-power radio transmitters, radar units, and highfrequency and high-current equipment.
Requirements
Capital
construction
Power cables
leading in the
equipment room
need to be
equipped with a
surge protector
l After the low-voltage power cables are led into the room, install the
surge protector for the power cables in the AC voltage stabilizer and
the AC power distribution panel (box). Correctly ground the surge
protector nearby.
l For an equipment room in urban area, install a power supply surge
protector with the nominal discharge current of no less than 20 kA.
For an equipment room that is built in a suburb and subject to lightning
strikes, install a power supply surge protector with the nominal
discharge current of more than 60 kA. For an equipment room that is
built in a mountain area and subject to frequent lightning strikes, or in
a separate high-rise building in a city, install a power supply surge
protector with the nominal discharge current of more than 100 kA.
l The ground cable of the surge protector should be no longer than 1 m
(3.28 ft).
Grounding for
DC power
distribution
Issue 08 (2015-05-08)
290
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Item
Requirements
Equipotential
connection
l Properly ground the devices and auxiliary devices in the room such as
mobile base station, transmission, switching equipment, power supply
equipment, and cable distribution frame. Connect all PGND cables to
the collective protective ground bar. Connect all PGND cables in one
equipment room to one protective ground bar.
l Apply joint grounding to the working ground and protective ground
of devices, which means the two share one grounding network.
l The cable tray, rack or shell, metal ventilation pipe, metal door or
window of the equipment should be grounded for protection.
General
requirements for
grounding
l Do not connect the neutral line of the AC power cable with the
protective ground of any telecom equipment in the equipment room.
l Do not install a fuse or switch on the ground cable.
l All ground cables should be as short as possible, and arranged in a
straight line.
l The grounding resistance must be lower than 1 ohm.
Grounding
resistance
l The upper end of the grounding body should be at least 0.7 m (2.30
ft) over the ground. In cold areas, bury the grounding body below the
frozen ground.
l Measure the grounding resistance periodically to ensure effective
grounding.
Routing of signal l Do not arrange the signal cables overhead in the equipment room. All
cable
signal cables must be led into the site underground.
l Use the cables with a metal jacket or place them into a metal pipe if
they come out/in the equipment room.
l Ground the idle lines inside the cable in the equipment room.
l Signal cables should be deployed on internal walls. Do not deploy
outdoor aerial cables.
l Keep signal cables away from power cables and surge protection
devices.
l Use a ground ring or ground bar for the collective ground cable.
Collective
ground cable
Grounding leadin
Issue 08 (2015-05-08)
291
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Item
Requirements
Grounding of the
cabinet
l All the devices including the surge protection device in the cabinet
must be connected in an equipotential manner. The ground cables can
be aggregated to the ground bar or surge protector socket first, and
then the ground bar or surge protector socket can be connected to the
ground.
l The resistance between the device ground terminals and ground bar
cannot exceed 0.1 ohm.
l The cabinet can be grounded using the protecting earthing (PE) wire
of the electrical network in the building, zinc-coated angle steel, or
the main steel bar of the building.
l If the cabinet is grounded using the PE wire of the electrical network,
use a multimeter to test the grounding status. If the voltage between
the PE wire and neutral wire is lower than 5 V and the voltage between
the PE wire and live wire is about 220 V, the PE wire is grounded well.
If the tested AC voltages are not within the ranges, the cabinet must
be grounded in other ways.
l The yellow-green ground cable contains multiple copper wires. The
cross-sectional area of the ground cable must be no less than 6 mm2
(0.0093 in.2) and the length cannot exceed 3 m (9.84 ft.).
l Ground cables cannot be twisted with signal cables.
l Antirust and anticorrosion measures must be taken on the ground
terminals.
l The fiber reinforcing rib can be directly connected to the ground bar
of the cabinet. Before wrapping the reinforcing rib with insulation
tape, cut a 0.5 m (1.64 ft.) segment from the reinforcing rib. Wrap the
reinforcing rib with at least five layers of insulation tape. Keep the
reinforcing rib at least 5 cm (1.969 in.) from the cabinet surface.
292
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
independent devices. Configure the current-carrying capacity of the protection switch of the
equipment room for more than that of the devices.
Table 14-19 lists the voltage range of the AC power supply for the devices.
Table 14-19 Voltage range of AC power supply
Item
Requirements
Frequency of alternating
current
The automated electric generator must have a standard interface that supports
telecommunication protocols, remote telecommunication, monitoring, and control.
AC power cables should meet the following specifications:
l
AC neutral should have a conductor with the same cross section as the phase line.
AC cables should have non-flammable insulation. The layout of AC cables should comply
with local regulations. Low-voltage power distribution rooms should comply with local
regulations.
If the voltage of the power mains that supply power directly to devices exceeds the rated
voltage by -10% to 5%, or exceeds the voltage range that devices can support, a voltage
regulating device or voltage stabilizing device is required.
If the mains do not supply power for the device directly, or if the mains voltage exceeds
the rated voltage by -15% to 10% or exceeds the input voltage range of the DC power
supply, a voltage regulating device or voltage stabilizing device is required.
Storage batteries are usually installed in a parallel connection of two groups. UPS storage
batteries are generally installed in one group. The redundancy required for the UPS can
rely on concatenation or parallel connection. When an inverter or a UPS is used, the active
inverter is determined by the maximum power and a backup inverter is required.
Issue 08 (2015-05-08)
293
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
A large-scale enterprise can deploy an independent power supply system on each floor to
supply power to the telecommunications equipment room on the respective floor.
A medium-scale enterprise can use a power room and a battery room for centralized power
supply or use distributed power supply systems.
A small-scale enterprise can deploy an integrated power supply system in its equipment
room but must take measures to prevent corrosive gases released from batteries from
eroding circuit boards of telecommunications equipment.
Requirements
-38 V to -72 V
DC power
capacity to
support the surge
current
Regulated
voltage precision
If the AC input voltage is in the range of 85% to 110% of the rated value,
and the load current is in the range of 5% to 100% of the rated value, the
output voltage of the rectifier ranges from -46.0 V to -56.4 V, with the
regulated voltage precision less than or equal to 1%.
Overshoot
amplitude of
switch on/off
Peak noise
voltage
200 mV
Dynamic
response
The recovery time is less than 200 ms. The overshoot is in the range of
the integral value of the DC output voltage 5%.
Use distributed power supply mode. Use multiple DC power supply systems and put power
equipment in multiple locations.
Adopt a standard DC power supply system, and set the output voltage to the
communications equipment within the required range.
Issue 08 (2015-05-08)
294
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Improve reliability of the AC power supply system to reduce the necessary capacity of
storage batteries. For small offices, increase the capacity of storage batteries if it is difficult
to enhance reliability of the AC power supply system.
The total capacity of the high-frequency switching rectifier must satisfy the power of the
communication loading and battery charging. If there are 10 or fewer active rectifier
modules, configure one backup module. If there are more than 10 active modules, configure
one backup module for every 10 active modules.
Install storage batteries in two or more groups. The capacity is determined by the duration
for which the storage batteries must supply power. For most offices, the batteries should
be able to supply power for at least one hour.
Description
The working ground and protective ground, including the shielded ground and the
lightning-proof ground of the cable distribution frame should share the same
grounding conductor.
The cable trays, shells, metal ventilation pipes, metal doors and windows in the
equipment room should be grounded for protection.
The metal parts of the equipment which are electrically floating in normal conditions
should be grounded for protection.
The ground cable must be connected securely to the protective ground bar of the
equipment room.
Do not use other equipment as part of the ground cable or electrical connection.
295
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Description
All communication devices and auxiliary devices (such as mobile base stations,
transmission and switching devices, power supply devices) in the equipment room
should be grounded for protection. Connect all protective ground for various devices
jointly to a general ground bar, and then to the same protective ground bar in the
room together with the protective ground (PGND) of the device.
The PGND of the equipment is shorted to the copper ground bar provided by the
customer. The short-circuiting cable used should be a yellow-green plastic insulated
cable with a copper core and a cross-sectional area greater than 25 sq. mm (0.039 sq.
in.).
There are grounding terminals and grounding lugs at the lower part of the front door,
rear door and side panel of the cabinet, connected to the grounding terminals of the
cabinet framework through connection cables with cross-sectional area of no less
than 1.6 sq. mm (0.002 sq. in.).
Ensure that all metal components of the cabinet conduct well. No insulating coating
should be sprayed on the connection part of the metal components.
Connect the cabinets in the same row by fastening captive screws and gaskets on the
top of the cabinets. Do not spray any coating into a rectangular area measuring 30
mm x 50 mm (1.18 in. x 1.97 in.) around the connection hole for a captive bolt.
Measures to prevent rust and corrosion must be taken for this area. Zinc electroplating
with iridescent yellow chromate conversion coating should be applied to the gasket
and nut to ensure good electrical contact.
When combining cabinets of the same type, short-circuiting cables are required to
connect the ground busbars (if any) of the cabinets. The cross-sectional area of the
short-circuiting cable is 6 sq. mm (0.009 sq. in.) and is no more than 300 mm (11.8
in.) long. Connect the two ends of the short-circuiting cable to the ground busbar
terminals of neighboring cabinets and fix them firmly.
Issue 08 (2015-05-08)
No.
Description
The inlet for the AC power cable at the equipment room should be equipped with a
surge protection device (C-level) with a nominal discharge current no less than 20
kA.
296
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
No.
Description
The protective ground for the power supply and that for communication equipment
share the same grounding conductor. If the power supply and the equipment are in
the same equipment room, use the same protective ground bar for them if possible.
The positive of the -48 V DC power supply or negative pole of the 24 V DC power
supply should be grounded at the output of the DC power supply.
The working ground and protective ground of the DC power supply equipment should
use the same grounding conductor with the protective ground of the switching
equipment. If the power supply and equipment are in the same equipment room, use
the same protection ground bar for them if possible.
Description
Equip the cable outdoors with a metal jacket, well grounded at both ends, or connect
the ends of the metal jacket to the protective ground bar of the equipment room. For
cables inside the equipment room, install surge protection devices at the interface to
the equipment. The PGND cable for the surge protection devices should be as short
as possible.
The incoming and outgoing signal cables to and from the office and unused wires
inside the cable should be grounded for protection.
The Tone & Data Access (TDA) cable must pass through the Main Distribution
Frame (MDF) with surge protective device (SPD) when going out of the office. The
cable's shield layer should be connected to the protective ground of the MDF. The
MDF should use the same grounding conductor as the cabinet.
Issue 08 (2015-05-08)
297
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Description
The grounding wire should not run parallel to or twist around the signal cable.
Bury ground underground or arrange them indoors. Do not route ground cables
overhead.
Do not connect two cables together to extend the PGND cable, or add any switches
or fuses.
The PGND cable should be an alternating yellow and green plastic insulated one with
a copper core.
The neutral line of the AC power cable cannot be connected to the protective ground
of transmission and communication equipment in the equipment room.
Signal cables include network cables, optical fibers, and user cables.
Fill in labels according to specified requirements to keep consistency of labels in the equipment room.
Make a relevant statement in the self-check report.
Issue 08 (2015-05-08)
298
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
To specify more clearly the position of a cable, use the dividing lines on the label. For example,
there is a dividing line between the cabinet number and the chassis number, and another one
between the chassis number and the slot number. Each dividing line is light blue (Pantone 656c)
and 1.5 mm x 0.6 mm (0.06 in. x 0.02 in.).
The cut dotted line helps to fold the label when affixed to the cable, and its size is 1 mm x 2 mm
(0.04 in. x 0.08 in.).
The word "TO:" (upside down in the figure) at the lower right corner of the label is used to
identify the opposite end of the cable on which the label is affixed.
299
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Label Printing
The contents can be printed or written on the labels. Printing is recommended for the sake of
high efficiency and eye-pleasant layout.
300
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
You can modify the contents of the template. Do not change settings of centered characters,
direction, and fonts.
If many characters need to be filled in, decrease the font size, but make sure that the printouts
are clear and legible.
2.
Select Format/Borders and Shading/Borders. Select Box tab and click OK.
3.
Drag the mouse to select cells to be merged and select the Table/Merge Cells.
Try printing on ordinary paper with both sides blank. Place the blank paper over the whole
page of the label paper, and check whether the page setup conforms to the label layout.
2.
Make sure the printer properties, such as "paper size" and "direction", have been set
correctly.
l If the printout conforms to the sheet of labels, print the labels on the label paper.
l If the printout does not conform, adjust the page setup and try printing again until the
correct printout is produced.
2.
3.
Select the Margins tab page. Select Left for Gutter Position and adjust the values of Top,
Bottom, Left, and Right.
NOTE
If the warning prompt as shown in Figure 14-83 appears before printing, click Ignore to continue
the printing.
After the page setup has been made correctly, save it for future use. This page setup is only
necessary the first time you use the template to print the labels.
Issue 08 (2015-05-08)
301
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
All the printouts must be on the label, and nothing should be printed on the backing layer
of the label page.
Contents in the cells should be aligned in the center. In a single-line printout, the dividing
lines and the word "TO:" should not be covered by printed characters.
When the cells are merged and the printouts are made in multiple lines, avoid covering the
word "TO:" when printing the text. Use the space bar to move the text to the next line.
Writing Labels
Writing Tools
To make sure the printouts are clear and legible, use black markers instead of ball-point pens to
write the labels.
If no marker is available, black ball-point pens are allowed, although not recommended.
Compared with ball-point pens, water-proof markers are better. When writing with a ball-point
pen, do not leave the oil on the label, which may contaminate the label and blur the words.
NOTE
The delivered marker has two nibs. Use the smaller nib to write the labels.
Font
For the sake of legibility, use standard block letters and numbers as shown in Table 14-26 (Times
New Roman).
Table 14-26 Standard typeface for handwriting
0
Determine the size of characters based on the number of letters or digits and ensure that the
characters are distinct and tidy.
Issue 08 (2015-05-08)
302
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Attaching Labels
After printing or writing the label, remove the label from the page and attach it to the signal
cable, or the identification plate of the power cable. The methods for attaching labels are
described in the following sections.
Issue 08 (2015-05-08)
303
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
The identification card is on the top of the cable in horizontal cabling. Make sure that the
label is facing out.
Issue 08 (2015-05-08)
304
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
TO:
B03
-48V2
-48V2
Cable
Area 1 contains the location information of the local end of the cable.
Area 2 (with the word "TO:") contains the location information of the opposite end of the
cable.
Seen from the cabling end of the equipment, the text part of the label is on the right side of the
cable. The side with "TO:" that is facing outside carries the location information of the opposite
end; and the other side carries the location information of the local end.
Issue 08 (2015-05-08)
305
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
In other words, the information in Area 1 at one end is the same as the information in Area 2 at
the other end of the cable.
Since the label paper is made of moistureproof material, ink-jet printers and ink pens cannot
be used to print and write labels.
Labels should be attached neatly. New-type labels are L-shaped. If they are pasted at
incorrect locations or in the incorrect direction, the appearance of the device is affected.
Power cable ties should be attached in the same positions on power cables, with
identification plates on the same side.
The positions of "up", "down", "left" or "right" are all based on the viewpoint of the
engineering person who is working on the label.
One is for the fiber that connects the optical interfaces on two devices.
The other is for the fiber that connects the device and the ODF.
Meaning
Example
MN-B-C-DR/T
MN: cabinet
number
Issue 08 (2015-05-08)
B: chassis
number
C: physical slot
number
306
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Content
14 Appendix
Meaning
Example
D: optical
interface
number.
R: Receiving
interface
T: optical
transmitting
interface
01
01
01
TO:
G01
01
01
A01
"A01-01-05-01-R" indicates that the local end of the optical fiber is connected to the optical
receiving interface 01 in slot 5, chassis 01 in the cabinet in row A, column 01 in the machine
room.
"G01-01-01-01-T" indicates that the opposite end of the optical fiber is connected with
optical transmitting interface 01 in slot 01, chassis 01 in the cabinet in row G, column 01
in the machine room.
Labels for the Optical Fibers Connecting the Device and an ODF
Meaning of the Labels
Table 14-28 shows information on both sides of labels attached to an optical fiber between a
device and an optical distribution frame (ODF).
Table 14-28 Information on labels affixed to a fiber between a device and an ODF
Issue 08 (2015-05-08)
Content
Meaning
Example
MN-B-C-DR/T
MN: cabinet
number
307
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
Content
14 Appendix
Meaning
Example
B: chassis
number
C: physical slot
number
D: optical
interface
number.
R: Optical
receiving
interface
T: optical
transmitting
interface
ODF-MN-BC-R/T
B: row number of
the terminal
device
C: column
number of the
terminal device
R: Optical
receiving
interface
T: optical
transmitting
interface
01
05
01
Issue 08 (2015-05-08)
01
TO:
A01
ODF G01
308
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
"ODF-G01-01-01-R" indicates that the local end of the optical fiber is connected to the
optical receiving terminal in row 01, column 01 of the ODF in row G, column 01 in the
machine room.
"A01-01-05-01-R" indicates that the opposite end of the optical fiber is connected to optical
receiving interface 1 in slot 05, chassis 01 in the cabinet in row A, column 01 in the machine
room.
Label Content
Table 14-29 shows the information on both sides of the labels affixed to Ethernet cables.
You can also decide the label content based on the actual environment. If the device is not
installed in the cabinet, for example, you can remove the cabinet number.
Table 14-29 Information on the Ethernet cables
Content
Meaning
Example
MN-B-C-D
MN: cabinet
number
B: chassis number
C: physical slot
number
D: network port
number
MN: cabinet
number
Z: Location
number
MN-Z
Issue 08 (2015-05-08)
309
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
The contents of the labels for network cables connecting hubs and devices or agents and the
network cables for other purposes should be specified according to actual connections. The
details are as follows:
l
For a network cable connecting a hub and device, the label on the hub end should indicate
the numbers of the chassis and cabinet where the hub resides, and the serial number on the
hub. The label on the device end should indicate the number of the chassis and cabinet
where the device is located. If the device is a standalone device, provide the specific position
of the device.
For a network cable connecting a hub and an agent or terminal, the label on the agent or
terminal end should contain the serial number of the network interface. The definitions of
the cabinet number and chassis number are the same as those described in Table 14-29.
If the hub is a standalone device without a cabinet or chassis, the label should contain
specific location information that identifies the hub.
The serial number on the hub, the network interface number of the agent or terminal, and the
location of the standalone device should be specified according to actual connections.
Label Example
Figure 14-91 shows a sample label on an Ethernet cable.
Figure 14-91 Sample label on an Ethernet cable
01
01
03
03
TO:
B02
A01
01
"A01-03-01-01" indicates that one end of the network cable is connected to network
interface 01 in slot 01, chassis 03 of the cabinet in row A, column 01 in the equipment
room.
"B02-03-01" indicates that another end of the network cable is connected to network
interface 01 in chassis 03 of the cabinet on row B, column 02 in the equipment room. No
slot number is given.
Issue 08 (2015-05-08)
310
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Meaning
Example
MN-B-C-D
MN: cabinet
number
B: frame number
C: physical slot
number
D: cable number
B: row number of
the terminal device
MDF-MN-B-C
C: column number
of the terminal
device
01
01
TO:
MDF G01
01
A01
01
"A01-03-01-01" indicates that the local end of the user cable is connected to port 1 in slot
1, chassis 03 of the cabinet in row A, column 01 in the equipment room.
"MDF-G01-01-01" indicates that the opposite end of the user cable is connected to the
terminal in row 01, column 01 of the MDF in row G, column 01 in the equipment room.
311
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Meaning
MN(BC)B--48Vn
MN(BC)-BBGND
MN(BC)-BPGND
The label only carries location information about the destination direction of the power cable
whereas information about the local end is unnecessary. That is, the label only carries location
information about the opposite equipment, the control cabinet, or the distribution box. Table
14-31 lists the information on two -48 V power supplies on the label. The information on other
DC voltages, such as 24 V and 60 V should be given in similar methods.
Make sure that labels are affixed in the correct direction. That is, after the cable ties are bundled
onto the cable, the identification plates with the labels should face up, and the text on the labels
in the same cabinet should be in the same direction. For details, see Figure 14-93.
Figure 14-93 Example of the labels for DC power cables
Issue 08 (2015-05-08)
312
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
On the loaded cabinet side, the label "A01/B08--48V2" on the cable indicates that the cable
is -48 V DC supply, which is from the eighth connector in row B of -48 V bus bar in the
cabinet in row A, and column 1 in the equipment room.
On the distribution box side, the label "B03--48V2" indicates that the cable is -48 V DC
supply, connected to DC power socket 2 in row B, column 03 in the equipment room.
NOTE
In the power distribution box or the first power cabinet of a row in a transmission equipment room, every
terminal block on the -48 V connector bar has a numeric identification. For example, in the above label of
"A01/B08--48V2", "08" (or sometimes "8") is the numeric identification of the terminal block.
PGND and BGND are two copper bars, on which the terminal blocks are short-circuited.
Therefore, it makes no difference which terminal is connected to them. It is only necessary to
give the row and column of the power distribution box, instead of giving the specific serial
number of the terminal block on the copper bar. For example, if the label on the loaded cabinet
side is "A01-BGND", it means that the power cable is a BGND that connects BGND copper bar
in the power distribution box in row A, column 01 in the machine room. Information on the
labels for PGND cables should be given in a similar way.
Meaning
MN-(B)-ACn
MN: serial number of the cabinet or the socket where the power is led in
B: chassis number, numbered in bottom-up order with two digits, for
example, 01.
n: power port number, numbered as 1 to 3 in bottom-up and left-to-right
order.
Serial number of the socket where the power is led in: the location of the
socket is marked according to the actual situation. If the sockets can be
identified by row numbers and column numbers, they can be numbered
following the same rule for the cabinets. If the sockets cannot be identified
by rows and columns, specify the detailed locations to avoid confusion
with other sockets.
The label only carries location information about the opposite equipment and the power socket;
information about the local end is unnecessary.
Issue 08 (2015-05-08)
313
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
Make sure that labels are affixed in the correct direction. That is, after the cable ties are bundled
onto the cable, the identification plates with the labels should face up, and the text on the labels
in the same cabinet should be in the same direction, as shown in Figure 14-94.
Figure 14-94 Labels for AC power cables
On the equipment cabinet side, the label marked "A01-AC1" indicates that the power cable
is connected to the first AC power socket of row A and column 01 in the equipment room.
On the power socket side, the label marked "B01-AC1" indicates that the power cable is
connected to the first AC power socket in the cabinet of row B and column 01 in the
equipment room.
2.
3.
The preceding faults lead to temporary or long-term cut-off of optical signals; or even cause
permanent damages to the optical module, affecting communication services.
Issue 08 (2015-05-08)
314
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
When installing an optical module, insert it in position. If you hear a click or feel a slight
shake, it indicates that the latch boss is secured.
If the latch boss is not secured, the gold finger of the optical module is not in good contact
with the connector on the board. In this case, the link may be connected but optical signals
will be cut off or the optical module will be loosened when the optical module is shaken
or hit.
2.
Figure 14-95 shows the release handle on an optical module when it is open and closed.
When inserting the optical module, make sure that the release handle is closed. At this time,
the latch boss locks the optical module. After the optical module is inserted, try pulling it
out to see if it is installed in position. If the optical module cannot be pulled out, it is secured.
Cleaning tissues must be prepared on site. You need to clean the optical connector before
inserting it in the receptacle. This protects the receptacle against contamination on the
surface of the optical connector.
Figure 14-96 Cleaning optical fibers with special cleaning tissues
NOTE
Place at least three cleaning tissues on the work bench. As shown in Figure 14-96, wipe the end of
an optical connector from left to right or from right to left on a cleaning tissue, and then move the
connector end to the unused part of the cleaning tissue to continue.
2.
Issue 08 (2015-05-08)
Cover an unused optical module with a protective cap to prevent dust, as shown in Figure
14-97.
Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
315
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
If no protective cap is available, use fibers to protect the optical module, as shown in Figure
14-98.
Figure 14-98 Using fibers to protect an optical module
3.
Cover unused optical connectors with protective caps, as shown in Figure 14-99, and then
lay out fibers on the fiber rack or coil them in a fiber management tray to prevent fibers
from being squeezed.
Figure 14-99 Installing a protective cap on a fiber
4.
Issue 08 (2015-05-08)
If a receptacle or an optical connector has not been used for a long time and is not covered
with a protective cap, you need to clean it before using it. Clean a receptacle with a cotton
swab, as shown in Figure 14-100. Clean an optical connector with cleaning tissues.
316
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
14 Appendix
NOTICE
When cleaning a receptacle, insert the cotton swab and turn it slowly in the receptacle. Do
not use too much strength because the receptacle may be damaged.
5.
If optical signals are lost during the operation of a device, use the preceding method to
clean the receptacle or the optical connector. In this manner, the possibility of contamination
can be excluded.
Before using an optical time-domain reflectometer (OTDR) to test the connectivity or the
attenuation of optical signals, disconnect the optical fibers from the optical module.
Otherwise, the optical module will be burnt.
2.
When performing a self-loop test, use an optical attenuator. Do not loosen the optical
connector instead of the optical attenuator.
1.
The optical connector should be vertically inserted in the receptacle to avoid damages to
the receptacle.
2.
Fibers must be inserted into optical modules of the corresponding type. That is, multimode
fibers must be inserted into multimode optical modules, and single mode fibers must be
inserted into single mode optical modules. If a fiber is inserted into an optical module of a
different mode, faults may occur. For example, optical signals will be lost.
Precautions
Fax:
317
Huawei
AR120&AR150&AR160&AR200&AR500&AR510&AR1
200&AR2200&AR3200&AR3600 series Enterprise Routers
Hardware Installation and Maintenance Guide
BOM
Code
Product
Description
Bar
Code*
14 Appendix
Fault
Occurring
Date*
Description
of the Fault
Phenomena*
Category
No.*
Software
Version*
Issue 08 (2015-05-08)
318