Você está na página 1de 36

LGR Column Formwork

The new range of panels: light and handset

Construccin

IMPORTANT:
Any safety provisions as directed by the appropriate governing
agencies must be observed when using our products.
The pictures in this brochure are snapshots of situations at
different stages of assembly, and therefore are not complete
images. For the purpose of safety, they should not be deemed
as definitive.
All of the indications regarding safety and operations
contained in this brochure, and the data on stress and loads
should be respected. ULMA Construccins Technical
Department must be consulted anytime that field changes
alter our equipment installation drawings.
Our equipment is designed to work with accessories and
elements made by our company only. Combining such
equipment with other systems is not only dangerous but also
voids any or all our warrantees.
The company reserves the right to introduce any modifications
deemed necessary for the technical development of the
product.

All rights reserved


Neither all nor part of this document may be reproduced or
transmitted in any way by any electronic or mechanical
procedure, including photocopy, magnetic recording or any
other form of information storage or retrieval system without
the written permission of ULMA Construccin.
National Book Catalogue Number: SS-854-2009

LGR Column Formwork


4
12
16
20
25
26
28
32

Product description
Assembly, use and disassembly
Solutions
Handling and maintenance conditions
Legal and standard references on health and safety
in the workplace and environmental risks
Components and accessories
ULMA Construccin addresses
Our products
Safety note
Control note
Warning note
Information note

LGR Column Formwork

Product description
Bet for new materials

The LGR is a light vertical formwork system created for framing rectangular
columns, and it is focused toward residential building. This system is comprised
of a range of handset panels in all existing sizes.
The constant research of ULMA Construccin has led to bet for new materials
like plastic. This type of product used in LGR formwork offers advantages to the
customer-operator and environment: increases durability and the life of the
formwork, reduces weight and facilitates its manipulation, is recyclable ...

Main features:
Rectangular columns framing system composed of light handset panels.
The panels shuttering face is made of plastic. The board is riveted to
the metal frame, providing lightweight to the panels and excellent
finishing.
Fixing elements are integrated in the panel and they cannot be lost.
These elements solve the union between panels in a simple way.
Reduced number of components.
Permits pouring dwarf walls joining laterally the panels using clamps.
Robust system, metallic frame with reinforced corners, which guarantees a
longer useful life for the panels.
Maximum allowable concrete pressure: 80 kN/m2. Up to a height of 3 m, it
is not necessary to control the pouring speed.
Range of system:
Panel heights: 3 m, 1 m and 0.5 m.
Width range: 0.7 m and 0.5 m.

4
Construccin

LGR Column Formwork

ULMA Construccin has developed the ideal product for maximum efficiency and economy of work in the
implementation of columns and dwarf walls: LGR Column Formwork.

Panels:
A product with long life
L

The panels are the main elements on column forming.


They are positioned and fixed in mill cross shape.

The range of LGR panels:


Height: 3 m, 1 m and 0.5 m
Width: 0.7 m and 0.5 m

5
Construccin

LGR Column Formwork

The frame has reinforced corners. These panels have


a perimeter frame made of steel profile, which can be
used with lateral joint clamps.
Two different profiles are used to make the ribs that
are welded to the frame to provide frame stiffness:
- Multipunched steel profile rib supports the safety tie
system.
- Rectangular tube, that has a reinforced hole with
bushing, permits assembling different formwork
accessories.
The shuttering face is made of 16 mm thick
plastic plywood that fits in the steel frame to which
it is riveted. The plywood edge is protected by the
perimeter profile.

Lift ring

Reinforce corner
element
F

Detail F
A

Riveted plastic
board
B

Detail A

Fixing elements are included in the panel, they


cannot be lost and are removable.
Detail B

Metal frame

Tubular rib
Sliding nut
C

Multipunched
rib

Detail C
D

Hollow for
crow bar

Bolt

Detail E
Detail D
L Panels description

6
Construccin

LGR Column Formwork

The tying system, which is comprised of a Sliding nut


and a Bolt, is part of the panel. These complements are
inside the multipunched and they can slide along the
rib. Both components are safely locked in the rib so
that they cannot be lost, but they are removable in
case of damage.

The frames four corners are reinforced with casting


elements that are welded to the profiles, which also
provide notches that can be used in conjunction with a
lever to position the panel.

L Detail of the Sliding nut and the Bolt

7
Construccin

LGR Column Formwork

Lifting:
Elevation with security and safety

Lifting hook

The Lifting hook is an auxiliary component used for lifting


single panels or gangs with a crane.
It is designed to lift a maximum load of 1,200 kg with a
maximum sling angle of 30 with respect to the vertical.
Two hooks will be used for lifting a full pillar.
The hook is stamped with the CE mark in compliance
with the European directive 98/37/CE on machinery.

L The Lifting hook must be used following the advices and instructions of
ULMA Construccin
L

L Placement of the Lifting hooks on the panels

8
Construccin

LGR Column Formwork

In addition, 3 m height panels have a Ring for lifting


instead of using the Lifting hook.

Opening the hook

Placing the hook

Basic hooks assembly

Fastening the hook

L The lifting elements must be inspected before each use


L

9
Construccin

LGR Column Formwork

Stabilizing system:
Guaranteed balance
Elements used during panel assembly to stabilize them
against wind loads and to plumb the formwork once it
is assembled. The system uses adjustable props to
support both tensile and compression stresses.

L Stabilizing system

It is comprised of the following:


Push-pull prop: tubular body that is adjustable sliding the inner tube to acquire the proper
length. The final adjustment is made by a nut. The range of Push-pull prop:
Push-pull prop 1.55-2.5
Push-pull prop 2.5-3.85
Push-pull prop head: an element that joins the panel and the Push-pull prop. It is tied with a Panel bolt and a
nut through the hole in the ribs.
Push-pull prop shoe: this element is incorporated in the main push-pull prop 2.5-3.85 and it is used to anchor
push-pull props to the foundation through the holes include on it. Its recommended to use HSA M20X125 Hilti
anchors.

10
Construccin

LGR Column Formwork

Stabilization settings:
FORMWORK HEIGHT

PUSH-PULL PROP 1.55-2.5

3m

H = 2.4 m
L = 2.7 m

3.5 m

H = 2.6 m
L = 2.9 m

DRAWING

PUSH-PULL PROP 2.5-3.85

4m

H = 0.5 m
L = 1.7 m

H = 3.1 m
L = 3.3 m

4.5 m

H = 0.5 m
H = 0.6 m

H = 3.1 m
L = 3.4 m

5m

H = 0.5 m
H = 1.6 m

H = 3.5 m
L = 3.85 m

Chamfer strip
Sharp edges on the columns can be avoided by using Chamfer strips. This is a plastic component that is placed between
two panels joined together at 90 angles; it is not necessary to nail it to the plywood because its special shape allows it to
brace the profile. It also has slotted holes necessary to permit passing the Bolt through the lateral holes of the panel.

L Chamfer strip placing on column

L The positioning of the Chamfer strip to the panel is made without any
additional element

L Column finishing with chamfered corners

11
Construccin

LGR Column Formwork

Assembly, use and disassembly


LGR column formwork system, for its lightness, allows manual and crane assembly and disassembly.

Manual assembly
The assembly process described below refers to a column formwork assembly manipulated without crane. It may vary
depending on the required geometry:

L Fixing detail

1 Position one panel perpendicular to another (in an L shape), facing the lateral profile holes to the multipunched
L

rib holes.
Insert the bolts in the panel holes in accordance with the column dimensions to be obtained. Tighten the nuts.

2 Assemble the Push-pull prop heads and the


L

Push-pull props on the panels.


Anchor the Push-pull prop shoes using Hilti HSA
M20x125 anchors.
Place reinforcement, if this was not done previously.

3 Assemble the other L gang as explained in the


L

previous points without stabilizing system, or join the


rest of the panels one by one with the LGR Bolts and
nuts with the column dimensions.

12
Construccin

LGR Column Formwork

4 Pour the concrete using the appropriate auxiliary


L

equipment.

5 Once the concrete has cured completely, stripping can


L

begin.
Release the Bolts and the nuts to dismantle the
panels.
Perform maintenance work and cleaning on the
panels.

13
Construccin

LGR Column Formwork

Disassembly basic process


Disassembly with crane

1 Start with the column formed and forged.


L

2 Using reglamentary auxiliary equipment, place the


L

Lifting hooks on the panels or connect the slings to the


rings.
Release the nuts and disconnect the panels without
dropping.
Remove the panels from the concreted column with a
lever.

14
Construccin

LGR Column Formwork

3 Remove panel gang with the crane, for following


L

uses or pours in the implementation of the


following pillars.

4 Once all the columns are executed, down panel


L

gangs on the ground and disassemble them.


Perform any maintenance and cleaning work on the
panels.

15
Construccin

LGR Column Formwork

Solutions
The right product for column
geometries

Columns
The LGR panel can be used to frame columns of varying
cross sections (from 15 cm to 60 cm per side), it is
adjustable up to 5 cm.
These column panels have several ribs with holes,
punched every 5 cm, through which the Bolts are
inserted. Depending on the hole used, the column
dimensions will vary.
PANEL WIDTH

0.7 m Panel

0.5 m Panel

Minimum column (mm)

300 x 300

150 x 150

Maximum column (mm)

600 x 600

400 x 400

L Column stabilized with Push-pull props

L Panel fixing with Bolt and Sliding nut

16
Construccin

LGR Column Formwork

Vertically connecting panels


To execute high columns (taller than 3 m), two panels
must be vertically joined together, always positioning
the small panel below to facilitate and ensure the
assembly from the ground.

L The clamp ensures the hermetic joint


between panels; it is also capable of
connecting fillers up to 12 cm.

L The smaller panel must be placed at the bottom

The join between two panels is preferably done with


two Adjustable clamps.
In these cases, the maximum allowable column
height is 5 m, always positioning the small panel
below.
The concrete pouring speed is limited based on a
panel resistance of 80 kN/m2.
L Panels join with two clamps

17
Construccin

LGR Column Formwork

Dwarf walls
To execute columns with a cross section larger than
60 cm, the panels must be joined laterally using Clamps.
In these cases, the height of the dwarf walls is limited
to a maximum of 5 m (always positioning the small
panels below). The panels must be joined face to face
using intermediate 15 Tie rods.
For the tying system, besides using these Tie rods, it is
possible to use Sliding nuts incorporated in the panel's
multipunched rib or the Plate washer nut 15, supported
on the outside of the multipunched ribs. To permit
recovering material and reusing it, the rods are
protected by plastic Spacer tubes 22/25 that are
inserted between panels supported on cones.

PANELS WIDTH

0.7 + 0.7 m

0.7 + 0.5 m

0.5 + 0.7 m

0.5 + 0.5 m

Minimum dwarf walls (mm)

1000

850

800

650

Maximum dwarf walls (mm)

1300

1100

1100

900

L Dwarf wall joined with clamps

L Panels tied with Plate washer nut 15

L Dwarf walls top view


L Panels tied with Sliding nut

18
Construccin

LGR Column Formwork

L The characteristics and qualities of the panel provide excellent finishes

Work at high elevations, such as pouring concrete,


should be carried out from safe and stable work
platforms that prevent workers from falling.
It can be used independent lifting platforms or
working platforms integrated in the formwork.
The walkway bracket is installed by inserting its pin
in the ribs' tie hole and the stop is supported on the
lower ribs to provide stability.
The platform is created by nailing the wooden planks
to the plastic strip on the walkway bracket and
installing handrails and toeboards using planks.
Walkway bracket load capacity: 150 Kg/m2.

L Walkway bracket
fixing detail

The lateral union for dwarf wall solutions, is made


according to next criteria:

LGR panel dim.

N clamps in height

LGR panel 3 m

5 clamps

LGR panel 1 m

2 clamps

LGR panel 0.5 m

1 clamps

L Work platform on bracket

19
Construccin

LGR Column Formwork

Handling and maintenance conditions


Use conditions
General use conditions
Follow the instructions for the project in execution at all times.
Follow the general manufacturers instructions at all times.
Formwork shall be put up and stripped by qualified personnel, who
are supervised, overseen and managed by a competent person.
If working close to high voltage power lines, power should be
shut off while work is in progress. If this is not possible, take the
necessary protective measures recommended in the current
applicable standard.
Work will not be done on the formwork when wind speeds are in
excess of 60 km/h or when there is ice or snow.
The crane used must be strong enough for the handling and assembly
of the gangs.
The auxiliary lifting elements should be appropriate for the loads to
be lifted. They should be checked before each use and discarded if
found to be faulty.
If the Lifting hook is used, it should be used following the instructions
provided by the manufacturer.
If due to conditions of the work environment, the crane operator
does not have the capacity to view the whole trajectory over
which the load is moved, the transport operations will be guided
by a signalman, who will communicate with the crane operator
using predefined signals.
Under no circumstances shall people loiter beneath or in the path
of elevated loads.

Formwork
For stacking formwork panels on the ground, frames will be placed
on planks or similar materials and distributed to avoid any damage,
facilitating organization, cleanliness and posterior distribution of the
panels to their assembly positions.
All gang positioning and assembly processes will be performed
following safe work procedures.
They will be levelled and stabilized properly depending on the terrain
and/or weather conditions.
New gang shall not be mounted in the working area until the previous
gang has been properly secured.
Do not leave any element partially assembled.
The working platforms should never be overloaded. Only elements
required for fluid work flow should be stacked on them.

20
Construccin

LGR Column Formwork

Assure proper tying between the nut and the bolt so as to make
sure that no grout is lost through the joints.
Make sure that all the plate washer nuts are properly tightened,
the push-pull props are properly placed and tightened and the
push-pull prop shoes are correctly tied to the ground.
Respect the maximum pressures of the formwork system
(according to product instructions).
The formwork surfaces should be checked and cleaned before
pouring concrete.
Release agent should be applied to a cloth or brush and used to
clean the panels after each use. Do not use wire brushes that
could damage the film on the plywood.
In general, it is not recommended to use nails, screws or similar
fasteners.
Panels should always be stored after their last use at the
construction site. Before stacking the panels, they must be
cleaned. Then, they should be stacked by placing a wooden piece
between one panel and the next. They should be kept off the
ground by stacking them on supports that are levelled, and they
should be stored under a roof.
Release agent
Release agent should be used to keep concrete from sticking to the
formwork, thus increasing number of times a panel can be used.
The release agent plays an important role in assuring the quality of
the concrete surface. It serves the purpose of assuring there are no
surface holes and that colour is uniform.
It should be applied uniformly and in thin coats at all times. Usage
and correct use guidelines should be taken into account at all times.
The panel surfaces should be cleaned carefully before applying the
release agent.
It is recommended to clean the metal frame and apply the release
agent to the frame every 4 or 5 pourings.
Pouring
It is recommended to pour the concrete from the lowest possible
height; never higher than 2 m if it is not poured through a conduit,
pipe or other pouring accessory. It is convenient to pour as close as
possible to the base, without pouring directly against the formwork
at a single point.
The condition of the formwork will be overseen while pouring
concrete. Pouring will be stopped if any incident is detected.
Do not permit concrete to splash on the high sides of the panels so
as to assure that it does not cause stains.
If concrete is poured from a bucket, special care should be taken to
avoid hitting the formwork with the bucket and to avoid exceeding
the cranes load limit.
21
Construccin

LGR Column Formwork

The appropriate compacting system should be used based on the


concrete specifications. This should be appropriate for the vibrator
used.
Internal needle vibrators are better for compacting the concrete on
site, and the external vibrators, which vibrate through the panels,
should not be used. The needle vibrator should penetrate the
concrete by 10 to 15 cm.
The needle vibrator should never come in contact with the formwork
surface to assure the expected loads are not exceeded.The vibrator
should penetrate the concrete quickly, and be held still, vertical or
slightly inclined for 10 to 30 seconds or until the concrete flows back
to the surface.
Remove the vibrator slowly and carefully.

Stripping and curing


Before stripping, the concrete must comply with a minimum resistance
to avoid losing concrete next to the surface since this would affect the
surface resistance and durability of the concrete.
The time before beginning the dismantling process should be
increased when there are low temperatures or strong winds that
could result in quickly drying the surface.
The same time interval should be respected while stripping other
elements from the construction area. From the surface quality
point of view, this is justified since the surface quality is directly
linked to and influenced by the time over which the surface is
isolated from the surrounding environment.
While stripping, check that there are no people near and verify that
there is no loose material that can fall from the platforms.
Vertical elements should be stripped from top to bottom.
Once the gang is stripped, it will be supported on the frames
where it will then be cleaned and totally disassembled if no more
concrete is going to be poured.
Before using any material, it should be checked to confirm that all
components are in proper working conditions.

Personal and collective protective equipment


Regulatory safety equipment should be used when working, or
working platforms with their corresponding safety handrails should
be used (collective safety equipment).
Personal Protective Equipment to be used should include at least:
helmet, safety footwear, gloves and a tool belt.
Other Personal Protective Equipment should be used depending on
the site guidelines, based on risk assessments.

22
Construccin

LGR Column Formwork

Handling conditions
Proper storage of components is a fundamental necessity for their
preservation.
Optimal storage conditions are the following:
- Place the pieces of the same type and dimensions on or in
elements that have been exclusively designed for them (baskets,
pallets, boxes, etc.).
- In order to avoid part deformation, do not strap the metal strips
too tightly.
- Apply the metal strips sufficiently tight to assure the parts cannot
move.
- Use protectors to guard the components from the excessive
pressure exerted by the metal strips.
- Do not permit parts to hit against one another while the material
is being moved.

Repairing
ULMA Construccin has specific equipments for cleaning, repairing
panels and replacing board.

Lifting hook
The Lifting hook should be used in a way it does not put in danger
the integrity of people.
The Lifting hook cannot be used in applications not described in the
Users Guide.
The Lifting hook can only be used to raise panels and gangs for
systems specifically designed by ULMA Construccin, LGR in this
case. It will never be used for other applications or other formwork
systems.
In case the Lifting hook does not work properly, it will have to be
taken back immediately to be repaired.
The Lifting hook must not suffer strong knocks and excessive
crushing during its handling, storage, transport and, mainly,
when shifting the Panel from these Brackets.
The Lifting hook will remain in a place protected from the
atmospheric and aggressive agents to avoid its deterioration.
In case anyone who manipulates the Lifting hook notices any
deterioration in it, he/she will immediately take it back to have it
repaired.
The revision and reparation of the Lifting hook will be carried out
by the staff authorised by the manufacturer.

23
Construccin

LGR Column Formwork

Make sure that the used wire rope slings to raise the panels are
placed in a symmetric way.
Check visually the state of the Lifting hook before any use,
discarding it if any problem.
In long term jobsites the components will be revised periodically
(every six months) by qualified personnel.
Never stay under the lifted load.
Panels will be raised slowly, avoiding sudden movements. When
raising the panel do not stay near it. Lift it some centimetres and
check the correct placement of the slings.
If the Lifting hooks are not working properly, the panel will be
placed on the ground and all the mistakes will be corrected.
If the load has to be guided, cords and other auxiliary means will
be used. These means will be placed in the panel in advance.
If the crane operator does not have visual control of the whole
course, the displacement labours of the panels will be guided by
someone qualified to do it. Never guide the load with the hand.
Gloves and safety boots with metallic toecap will always be used
for hand and feet protection when placing Lifting hook and raising
panels. A helmet will always be used to protect the head.
Handlings will be carried out in places with enough visibility (more
than 100 Lux).
Checking instructions
The hook must be verified at least once a year by qualified personnel from ULMA Construccin or, by someone that
has been previously qualified and authorised by ULMA Construccin.
For the overhaul of the Lifting hook check the parts specified in the next table:
CONTROL TYPE

COMPONENT

FAULT

REVISION FREQUENCY

CRITICAL YES / NO

REPAIR

Fixed and mobile


parts

Fissured welding, broken


or with an important
corrosion

Every use and every time it


goes out from the store to
the jobsite

Yes

Scrap

Staple

Deflection or excessive
erosion

Every use and every time it


goes out from the store to
the jobsite

Yes

Scrap

Hexagonal screw nut

Check the bundle of the


components. Deflections.
Missing component.

Every use and every time it


goes out from the store to
the jobsite

Yes

Replace
components

Spring

Missing component

Every use and every time it


goes out from the store to
the jobsite

No

Replace
components

Identification plate

Missing component

Every use and every time it


goes out from the store to
the jobsite

No

Replace
components

Surface appearance

Dirt that impedes the


functioning and mobility of
moving components

Every use and every time it


goes out from the store to
the jobsite

No

Clean

Visual

The self-blocking nut and hexagonal screw are for single use, so long as these elements are released, these
should be replaced by new ones.

24
Construccin

LGR Column Formwork

Legal and standard references on health and safety


in the workplace and environmental risks
Council Directive 89/391/EEC on the introduction of
measures to encourage improvements in the safety
and health of workers at work

Council Directive 89/656/EEC on the minimum health


and safety requirements for the use by workers of
personal protective equipment at the workplace

Council Directive 89/654/EEC on the minimum


safety and health requirements for the workplace

Council Directive 90/269/EEC on the minimum health


and safety requirements for the manual handling of
loads where there is a risk particularly of back injury to
workers

Council Directive 92/57/EEC on the implementation


of minimum safety and health requirements at
temporary or mobile construction sites
Council Directive 92/58/EEC on the minimum
requirements for the provision of safety and/or
health signs at work
Directives 89/655/EEC- 95/63/EC - 2001/45/EC
concerning the minimum safety and health
requirements for the use of work equipment by
workers at work

Directive 2002/44/EC on the minimum health and


safety requirements regarding the exposure of workers
to the risks arising from physical agents (vibrations)
Directive 2003/10/EC on the minimum health and
safety requirements regarding the exposure of workers
to the risks arising from physical agents (noise)
UNE-EN 13374 Temporary border protection systems,
product specifications, test methods

Agreement statement NEVI Lifting hook


AGREEMENT STATEMENT
According to Directive 98/37/CE concerning machines
Hereby ULMA C y E, S. Coop. declares that the product whose code and name are mentioned below complies with the design
and manufacturing aspects concerning peoples safety required by the corresponding European directive concerning the machines
98/37/CE, the standard UNE EN 13155 and UNE EN 729, being this the valid statement until the product suffers any modification.
Code: 1920835
Name: NEVI LIFTING HOOK

Signed

Oati, 23th January 2009


Aitor Ayastuy
Chairman

Agreement statement Lifting ring


AGREEMENT STATEMENT
According to Directive 98/37/CE concerning machines
Hereby ULMA C y E, S. Coop. declares that the product whose code and name are mentioned below complies with the design and
manufacturing aspects concerning peoples safety required by the corresponding European directive concerning the machines
98/37/CE, the standard UNE EN 13155 and UNE EN 729, being this the valid statement until the product suffers any modification.
Code: 9165401
Name: EYE BOLT SCREW M20 DIN580

Signed

Code: 9057200
Name: HEXAGONAL NUT M20 DIN985-8 ZINC COATED

Oati, 26th January 2009

Aitor Ayastuy
Chairman

25
Construccin

LGR Column Formwork

Components and accessories


Basic elements
WEIGHT (kg)

LGR Panel 3 x 0.7


LGR Panel 3 x 0.5

74.26
58.4

WEIGHT (kg)

CODE

LGR Panel 0.5 x 0.7


LGR Panel 0.5 x 0.5

16.9
12.9

1856075
1856080

NEVI Lifting hook

1920835

NEVI Clamp

3.96

1920851

Chamfer strip LGR 3 m


(16 units)

0.45

1856061

CODE

LGR Panel
1856050
1856065

LGR Panel

LGR Panel
LGR Panel 1 x 0.7
LGR Panel 1 x 0.5

29.5
22.6

1856060
1856070

26
Construccin

LGR Column Formwork

Stabilizing

Work Platforms - Anchors - Consumables


WEIGHT (kg)

Push-pull prop head

Push-pull prop 1.55 - 2.5

Push-pull prop 2.5 - 3.85

CODE

1.5

1856140

10.3

1856130

19.7

Hexagonal nut 15

0.4

0.22

ORMA Walkway bracket

CODE

12.2

1861094

Tie rod 15/1

1.7

0230100

Plate washer nut 15

1.4

1900256

Spacer tube 22/25


(75 ml)

0.3

7230455

Cone 22 (250 units)

0.006

7230264

Eye bolt screw


M20 DIN580

0.3

9165401

Hexagonal nut
M20 DIN985-8
zinc coated

0.06

9057200

1856120

ETALLE C

Panel bolt

WEIGHT (kg)

1861122

7238001

27
Construccin

Production Plant
ULMA C y E, S. Coop.
Ps. Otadui, 3 - P.O. Box 13
20560 OATI (Guipzcoa)
SPAIN
Phone: + 34 943 034900
Fax: + 34 943 034920
www.ulma-c.com

ULMA Worldwide
EUROPE
Germany
ULMA Betonschalungen
und Gerste GmbH
Paul-Ehrlich-Strae 8
D-63322 RDERMARK
Phone: + 49 6074 9294 0
Fax: + 49 6074 9294 101
www.ulma-c.de
Nordwest Branch
Stresemannallee 4c
D-41460 NEUSS
Phone: + 49 2131 40201 0
Fax: + 49 2131 40201 99
Sdwest Branch
Manfred - Wrner - Str. 115
D-73037 GPPINGEN
Phone: + 49 7161 50608 42
Fax: + 49 7161 50608 43
France
ULMA, S.A.R.L.
27, rue Gustave Eiffel
Z.I. de la Marinire
91070 BONDOUFLE
Phone: + 33 1 69 11 54 50
Fax: + 33 1 69 11 54 54
www.ulma-c.fr

IDF chafaudages Branch


22 Bis, rue Gustave Eiffel
Z.I. de la Marinire
91070 BONDOUFLE
Phone: + 33 1 69 11 63 30
Fax: + 33 1 69 11 63 31

Tarnos Branch
40, rue de lIndustrie
Z.I. de Tarnos
40220 TARNOS
Phone: + 33 5 59 64 44 45
Fax: + 33 5 59 64 44 84

IDF Construction Branch


27, rue Gustave Eiffel
Z.I. de la Marinire
91070 BONDOUFLE
Phone: + 33 1 69 11 63 40
Fax: + 33 1 69 11 63 37

Lons Branch
9, Avenue Larregain
Z.I. du Monhauba
64140 LONS
Phone: + 33 5 59 62 71 97
Fax: + 33 5 59 13 84 33

Eguilles Branch
50, alle Meulire
Z.I. - Route de Berre
13510 EGUILLES
Phone: + 33 4 42 64 62 30
Fax: + 33 4 42 64 62 31

Italy
ALPI, S.P.A.
Zona Industriale Est
I-39035 MONGUELFO (BZ)
Phone: + 39 0474 947 400
Fax: + 39 0474 947 499
www.alpionline.net

Saint Herblain Branch


11, rue Fondeur
Z.I. du Tisserand
44800 SAINT HERBLAIN
Phone: + 33 2 51 80 48 04
Fax: + 33 2 51 80 48 05
La Chapelle
dArmentires Branch
Zone Industrielle
Rue Andr Ampre
59930 LA CHAPELLE
DARMENTIRES
Phone: + 33 3 20 07 11 86
Fax: + 33 3 20 07 11 68

Kazakhstan
ULMA Kazakhstan
01000 ASTANA
6/2, Tashenova St. 4th floor, offices 7,9
Phone:/Fax: + 7 7172 58 05 19
Phone: + 7 7172 37 93 48
www.ulma-c.kz

Poland
ULMA Construccion Polska S.A.
03-115 WARSAW
ul. Klasykw 10
Phone: + 48 22 506 70 00
Fax: + 48 22 814 31 31
www.ulma-c.pl
WSCHD REGION
WARSZAWA Branch
Warszawa Office
03-197 WARSAW
ul. Laurowa 39
Phone: + 48 22 506 72 50
Fax: + 48 22 747 19 16
Olsztyn Office
10-467 OLSZTYN
ul. Sprztowa 3, lok. 18
Phone: + 48 89 537 73 10
Fax: + 48 89 532 04 95
LUBLIN Branch
Lublin Office
20-327 LUBLIN
ul. Wroska 2
Phone: + 48 81 749 72 90
Fax: + 48 81 744 04 90
Biaystok Office
15-100 BIAYSTOK
ul. 1. Armii Wojska Polskiego 9, lok. 203
Phone: + 48 85 676 73 00
Fax: + 48 85 675 06 53

28
Construccin

ZACHD REGION
POZNA Branch
61-317 POZNA
ul. Ostrowska 484
Phone: + 48 61 838 75 30
Fax: + 48 61 863 01 60

Nowa Sl Office
67-100 NOWA SL
ul. Kociuszki 29
Phone: + 48 68 376 77 60
Fax: + 48 68 387 02 21 wew. 357
POUDNIE REGION

BYDGOSZCZ Branch

KRAKW Branch

Bydgoszcz Office
85-739 BYDGOSZCZ
ul. Fordoska 199
Phone: + 48 52 323 76 80
Fax: + 48 52 345 25 65

Krakw Office
31-670 KRAKW
ul. Powstacw 66
Phone: + 48 12 620 73 70
Fax: + 48 12 647 34 22

Szczecin Office
70-676 SZCZECIN
ul. Gerarda Merkatora 7
Phone: + 48 91 485 77 30
Fax: + 48 91 462 53 11

Katowice Office
40-203 KATOWICE
al. Rodzieskiego 188b
Phone: + 48 32 356 74 80
Fax: + 48 32 353 33 90

GDASK Branch
80-298 GDASK
ul. Budowlanych 27
Phone: + 48 58 522 78 00
Fax: + 48 58 667 02 04

D Branch
94-250 D
ul. niwna 4/8
Phone: + 48 42 666 73 20
Fax: + 48 42 650 03 25

WROCAW Branch

Portugal
ULMA Portugal Lda.
Zona Industrial - Rua A, s/n
Vale de Figueira
2695 SO JOO DA TALHA - LISBON
Phone: + 351 219 947 850
Fax: + 351 219 558 022
www.ulma-c.pt

Wrocaw Office
50-541 WROCAW
ul. Armii Krajowej 53
Phone: + 48 71 391 76 30
Fax: + 48 71 367 30 90

Porto Branch
Zona Industrial da Feiteira
Rua das Casas Queimadas
717 Grij
4415-439 VILA NOVA DE GAIA
PORTO
Phone: + 351 227 418 820
Fax: + 351 227 418 829

Ukraine
ULMA Formwork Ukraine Ltd.
01013 KIEV
3, Derevoobrobna St.
Phone: + 380 44 255 14 92
Fax: + 380 44 255 14 94
www.ulma-c.com

Czech Republic
ULMA Construccin CZ, s.r.o.
Prmyslov 1009
294 71 BENTKY NAD JIZEROU
Phone: + 420 326 910 600
Fax: + 420 326 910 601
www.ulma-c.com
Slovak Republic
ULMA Construccion SK, s.r.o.
Rybnin 38/K
831 06 BRATISLAVA
Phone: + 421 2 4910 2911 - 13, 18
Fax: + 421 2 4910 2922
www.ulma-c.com
Romania
ULMA Cofraje s.r.l.
Sos Chitilei, 200
012405 - Sector 1 - BUCHAREST
Phone: + 40 31 425 13 22/23
Fax: + 40 31 425 13 24
www.ulma-c.ro

29
Construccin

Production Plant
ULMA C y E, S. Coop.
Ps. Otadui, 3 - P.O. Box 13
20560 OATI (Guipzcoa)
SPAIN
Phone: + 34 943 034900
Fax: + 34 943 034920
www.ulma-c.com

ULMA Worldwide
AMERICA
Argentina
ULMA Andamios y
Encofrados Argentina, S.A.
Bernardo de Irigoyen 722 6A
CP1072AAP CAPITAL FEDERAL
Phone/Fax: + 541 14 3425132
www.ulma-c.com.ar
Brazil
ULMA Brasil - Frmas e
Escoramentos Ltda.
Rua Joo Dias Ribeiro, 210
Jd. Sagrado Corao de Jesus
Itapevi - SP
CEP: 06693-810
Phone/Fax: + 55 11 3883 1300
www.ulma-c.com.br
Rio de Janeiro Branch
Rua Sargento Silva Nunes, 137
Ramos - Rio de Janeiro - RJ
CEP: 21040-231
Phone/Fax: + 55 21 2560 2757
Phone/Fax: + 55 21 2560 5541
Centro-Oeste Branch
Quadra 3, Lotes 680/700
Setor Industrial Leste
Gama - Brasilia DF
CEP: 72445-030
Phone/Fax: + 55 61 3556 6226
Salvador Branch
Travessa Dois de Fevereiro, 145
Centro - Lauro de Freitas - BA
CEP: 42700-000
Phone/Fax: + 55 71 3288 2003

Sul Branch
Rua Dr. Joo Incio, 195/199
Navegantes - Poa RS
CEP: 90230-180
Phone/Fax: + 55 51 3337 1003

West Branch (Phoenix)


1530 West Houston Avenue
Gilbert, ARIZONA 85233
Phone: + 1 480 304 4942
Fax: + 1 480 304 4948

Chile
ULMA Chile - Andamios y
Moldajes, S.A.
Vizcaya n 325 - Pudahuel
(Ruta 68, Camino Noviciado)
SANTIAGO
Phone: + 56 2 5990530
Fax: + 56 2 5990535
www.ulma-c.cl

Mid-Atlantic Branch (Baltimore)


8235 Patuxent Range Road
Jessup, MARYLAND 20794
Phone: + 1 443 296 9852
Fax: + 1 443 296 9860

Norte Branch
General Borgoa 934 of. 70
ANTOFAGASTA
Phone: + 56 5 5246770
Fax: + 56 5 5246960
Sur Branch
OHiggins 940 of. 904
CONCEPCIN
Phone: + 56 4 12522930
Fax: + 56 4 12228321
USA
ULMA Form Works, Inc.
58 Fifth Avenue
Hawthorne - NEW JERSEY 07506
Phone: + 1 973 636 2040
Fax: + 1 973 636 2045
www.ulma-c.us

Mexico
ULMA Cimbras y Andamios
de Mxico S.A. de C.V.
Va Gustavo Baz Prada 2160
Acceso 5
54060 Col. La Loma
TLALNEPANTLA
(Mexico State)
Phone: + 52 55 5361 6783
Fax: + 52 55 2628 3549
www.ulma-c.com.mx
Peru
ULMA Encofrados Per, S.A.
Av. Argentina 2882
LIMA
Phone: + 51 1 613 6700
Fax: + 51 1 613 6710
www.ulma-c.com.pe

ASIA-AFRICA
P.R. China
ULMA Formworks China R.O.
#1009 Fortunegate Mall
1701 West Beijing Road
SHANGHAI, 200040
Phone: + 86 21 62887070
Fax: + 86 21 62885980
www.ulma-c.com
UAE
ULMA Formworks UAE L.L.C.
Plot No. 597- 547
Dubai investments Park
P.O. Box. 282286
DUBAI
Phone: + 971 4 8858208
Fax: + 971 4 8858209
www.ulma-c.com
Singapore
ULMA Formwork
Singapore PTE. LTD.
2 Senoko Way
758027 SINGAPORE
Phone: + 65 6758 2338
Fax: + 65 6758 8523
www.ulma-c.com

Norte Branch
Ctra. Pomalca, km 2,7
Chiclayo - LAMBAYEQUE
Phone: + 51 7 460 8181
Fax: + 51 7 460 8182

30
Construccin

ULMA in Spain
ANDALUCA Branch

CASTILLA Branch

GALICIA Branch

LEVANTE Branch

Pol. Ind. Fridex


Autova Sevilla - Mlaga, km 4,2
41500 ALCAL DE GUADAIRA
(Sevilla)
Phone: 95 5630044
Fax: 95 5630020

Ctra. Burgos - Portugal, km 116


47270 CIGALES (Valladolid)
Phone: 983 581009
Fax: 983 581021

Pol. Ind. Espritu Santo


Rua Bell, 24-26
15650 CAMBRE (La Corua)
Phone: 981 649802
Fax: 981 649060

Pol. Ind. Los Vientos


Gregal, 7 - Apdo. 76
46119 NQUERA (Valencia)
Phone: 96 1399130
Fax: 96 1399096

Generoso Domnguez, s/n


Portela - Tameiga
36416 MOS (Pontevedra)
Phone: 986 344045
Fax: 986 304809

Pol. Ind. La Serreta


Cal, s/n
30500 MOLINA DE SEGURA
(Murcia)
Phone: 968 642679
Fax: 968 641276

Camino Nuevo, s/n


18210 PELIGROS (Granada)
Phone: 958 405028
Fax: 958 405328

Pol. Ind. de Roces, 5


Gustavo Eiffel, 46
33211 GIJN (Asturias)
Phone: 98 5168038
Fax: 98 5167513
CATALUA Branch

ARAGN Branch
Pol. Ind. El Pradillo II
Aneto, 2 - Parcela 23
50690 PEDROLA (Zaragoza)
Phone: 976 654645
Fax: 976 654635
CANARIAS Branch
Pol. Ind. Las Majoreras
Los Llanillos, 33
35259 INGENIO (Las Palmas)
Phone: 928 789212
Fax: 928 789538
Pol. Ind. Valle de Gimar
Manzana XIII - Parcelas 21 y 22
38509 GIMAR (Tenerife)
Phone: 922 505020
Fax: 922 501101

Pol. Ind. Sud - Est


Pintor Velzquez, 7 y 9
08213 POLINYA (Barcelona)
Phone: 93 7132727
Fax: 93 7133643
Pol. Ind. Son Noguera
Cas Rossos, 12-14
07620 LLUCMAJOR
(Illes Balears)
Phone: 971 669850
Fax: 971 121512

NORTE Branch
Pol. Ind. Goiain
Av. San Blas, 1
01170 LEGUTIANO (lava)
Phone: 945 001100
Fax: 945 001111
Iturritxualde, 3
48160 DERIO (Vizcaya)
Phone: 94 4521425
Fax: 94 4522468

CENTRO Branch
Pol. Ind. Sur
28863 COBEA (Madrid)
Phone: 91 6523199
Fax: 91 6528828
Ctra. N-401 Madrid-C. Real, km 87
45110 AJOFRN (Toledo)
Phone: 925 011000
Fax: 925 011008

31
Construccin

LGR Column Formwork

Our products
Vertical Formworks
ORMA Modular Formwork
A system for large works and
high performance

Circular Sheet
Formwork BIRA
Formwork system designed
for circular wall
configurations

ENKOFORM V-100
Bracing System
Wall and Column Formwork
with Steel Walers and Timber
Beams

LGR Column Formwork


Column formwork using light
panels

COMAIN Hand-held
Formwork
Modular Formwork that is
light and easy to handle by a
single person

CLR Circular Column


Formwork
Circular column formwork,
designed to solve the
different column diameters
easily

NEVI Modular Formwork


Vertical handset and gang
formwork system

Formwork Climbing
Systems
Climbing and self-climbing
systems for any height

32
Construccin

LGR Column Formwork

Notes

33
Construccin

LGR Column Formwork

Notes

34
Construccin

E00CBS13

ULMA C y E, S. Coop.
Ps. Otadui, 3-P.O.Box 13
20560 OATI (Guipzcoa)
SPAIN
Phone: + 34 943 034900
Fax: + 34 943 034920
ww w.ulma-c.com

Você também pode gostar