P.O. Box 105689, Riyadh 11656, KSA.

Request For Quotation: JUNCTION BOX


Purchaser Details:

Sub-Vendor Details:

RFQ Reference No.:

ENR15002_JB

ID

Contract No.:

ENR15002

Address:

Issue Date :

2-Aug-2015

Attention:

Quote Required Date:

6-Aug-2015

Tel. :

Total Attachments:

Refer below

Fax:

MR Number :

Total Pages :

E-mail:
Originator :

MA

A. Items to be quoted
Line Item

Descriptions

Unit

Quantity

Remark

Pieces

31

As per JB wiring and layout DWG

Set

31

As per JB wiring and layout DWG

Pieces

31

As per JB wiring and layout DWG

JUNCTION BOX ENCLOUSRES

TERMINAL BLOCKS

SS 316 Drain and Breathers

DIN RAIL

Set

31

As per JB wiring and layout DWG

WIRES DUCT

Set

31

As per JB wiring and layout DWG

SS 316 PLUGS

Set

31

As per JB wiring and layout DWG

Vendor Delivery Date

B. ARAMCO APPLICABLE SPECS


SR. NO.

Document

1 SAES-J-902
2 SAES-P-104
3 34-SAMSS-831

Title

Current Issue

Saudi Aramco Engineering Standard - Electrical Systems for Instrumentation

22-Jul-13

Saudi Aramco Engineering Standard - Wiring Methods and Materials

8-Aug-10

Saudi Aramco Material Specification Standard - Instrumentation for Packaged Units

6-Feb-12

C. INFORMATION REQUIRED WITH QUOTATION


Commercial offer
Technical offer contains below:
1- Junction Box Layout dimenstional DWG with internal arrangment
2- 3rd Party certifiate
3- BOM with specs and Part number
4- Enclosure and internal components Catalogs

C. Attachment
SAES-J-902

Saudi Aramco Engineering Standard - Electrical Systems for Instrumentation

SAES-P-104

Saudi Aramco Engineering Standard - Wiring Methods and Materials

34-SAMSS-831

Saudi Aramco Material Specification Standard - Instrumentation for Packaged Units

VE-536302

BASIS OF DESIGN FOR INSTRUMENTATION AND CONTROL

SPDP

Complete SPDP Folder

175-340200

INSTRUMENTATION for PACKAGED UNITS ITR

S-00-1130-0150 Rev.02H

PACKING PROCEDURE

S-00-1130-0151 Rev.02H

SHIPING PROCEDURE

SA-7907; Instrumentation (General)

NON MATERIAL REQUIRMENTS

ENR15002-IE-002_REV.00

JB WIRING DIAGRAM

ENR15002-IE-003_REV.00

JB INSISDE & OUTSIDE LAYOUT

D. COMPLIANCE SHEET
See Next sheet

<<<<<< COVER SHEET

JUNCTION BOX Compliance sheet


PROJECT DATA
PROJECT NAME
FACILITY
LOCATION
ENVIRONMENTAL CONDITION

ISSUED
REV

Condensate Polishing Package (J50-U-0200)


EPC13 Utilities Distribution Package
JAZAN
SAFE AREA

PROJECT SPECS

SAES-J-902
SAES-P-104
34-SAMSS-831
VE-536302

Saudi Aramco Engineering Standard - Electrical Systems for Instrumentation


Saudi Aramco Engineering Standard - Wiring Methods and Materials
Saudi Aramco Material Specification Standard - Instrumentation for Packaged Units
BASIS OF DESIGN FOR INSTRUMENTATION AND CONTROL

Aspect

ARAMCO requirements

PROJECT REQUIREMENTS

non-hazardous areas
NEMA Type 4X or IEC 60529 Type IP 66 box
Type 316 stainless steel body, door, and hardware
Continuously welded seams, finished smooth.
single door
Stainless steel hinge
door shall open from left-to-right or from right-to-left
Removable door

As per ARAMCO specs


As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs

1 Area classification
2 Enclosure rating
3 Enclosure construction
4 Door installation

5 Door lock

6 Mounting
7 Internal Installation

316 Stainless steel captive clamps.


316 Stainless steel captive screws may be used in lieu of captive clamps provided that the
screws do not penetrate the door gasket.
Keylocks and padlocks are not acceptable
External mounting brackets
All field junction boxes shall be mounted vertically
Collar studs for mounting inside panel
316 Stainless steel back panels
Data/Print pocket on inside of door
The DIN rail shall only be mounted on the inside panel (back-pan) of the junction box.

8 Earthing
9 DRAIN & BREATHER

10 CERTIFICATION
11 TERMINAL BLOK

The terminals shall be mounted on vertical DIN rails (i.e., horizontal DIN rails are not allowed).
The DIN rail must be insulated from the Enclosure
Ground stud for terminating A/C safety ground wire
Instrument enclosures and junction boxes having an internal volume exceeding 2,000 cm shall
be provided with Type 300 Series stainless steel breather and drain fittings, or a combination
breather and drain fitting
All instrument enclosures and junction boxes shall be third party certified. Self certification is not
acceptable
Terminal blocks shall be channel (rail) mounted,
strip type, with tubular box clamp connector and compression bar or yoke for wire termination.
As a minimum, the thickness of the terminals shall be 5 mm or higher.
Multi-deck and spring type terminal blocks are not acceptable
Terminals and terminal block accessories (e.g., DIN rail mounting brackets for electrical
insulation, busbar support blocks, end brackets, etc.) shall be fire retardant in accordance with
UL 94, V0.
Terminals and accessories shall be made of halogen free, high strength material such as
polyamide or equivalent. Brittle materials such as melamine shall not be used.

As per ARAMCO specs


As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
316 SS Drain & Breather must be provided

As per ARAMCO specs


As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs
As per ARAMCO specs

As per ARAMCO specs

Terminal strip spacing shall allow ample room for plastic wire ducts and permit training and lacing Min. 60 mm spacing between TB to JB sides and TB to ducts
of cables, and fanning of individual

<<<<<< COVER SHEET

2-Aug-15
000

Vendor compliance
comply
comply
comply
comply
comply
comply
comply
comply
Captive screws used in lieu of captive clamps as per latest SAES J
902

comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply

comply
comply
comply
comply
comply
comply

comply

comply