Sub-Vendor Details:
ENR15002_JB
ID
Contract No.:
ENR15002
Address:
Issue Date :
2-Aug-2015
Attention:
6-Aug-2015
Tel. :
Total Attachments:
Refer below
Fax:
MR Number :
Total Pages :
E-mail:
Originator :
MA
A. Items to be quoted
Line Item
Descriptions
Unit
Quantity
Remark
Pieces
31
Set
31
Pieces
31
TERMINAL BLOCKS
DIN RAIL
Set
31
WIRES DUCT
Set
31
SS 316 PLUGS
Set
31
Document
1 SAES-J-902
2 SAES-P-104
3 34-SAMSS-831
Title
Current Issue
22-Jul-13
8-Aug-10
6-Feb-12
C. Attachment
SAES-J-902
SAES-P-104
34-SAMSS-831
VE-536302
SPDP
175-340200
S-00-1130-0150 Rev.02H
PACKING PROCEDURE
S-00-1130-0151 Rev.02H
SHIPING PROCEDURE
ENR15002-IE-002_REV.00
JB WIRING DIAGRAM
ENR15002-IE-003_REV.00
D. COMPLIANCE SHEET
See Next sheet
ISSUED
REV
PROJECT SPECS
SAES-J-902
SAES-P-104
34-SAMSS-831
VE-536302
Aspect
ARAMCO requirements
PROJECT REQUIREMENTS
non-hazardous areas
NEMA Type 4X or IEC 60529 Type IP 66 box
Type 316 stainless steel body, door, and hardware
Continuously welded seams, finished smooth.
single door
Stainless steel hinge
door shall open from left-to-right or from right-to-left
Removable door
1 Area classification
2 Enclosure rating
3 Enclosure construction
4 Door installation
5 Door lock
6 Mounting
7 Internal Installation
8 Earthing
9 DRAIN & BREATHER
10 CERTIFICATION
11 TERMINAL BLOK
The terminals shall be mounted on vertical DIN rails (i.e., horizontal DIN rails are not allowed).
The DIN rail must be insulated from the Enclosure
Ground stud for terminating A/C safety ground wire
Instrument enclosures and junction boxes having an internal volume exceeding 2,000 cm shall
be provided with Type 300 Series stainless steel breather and drain fittings, or a combination
breather and drain fitting
All instrument enclosures and junction boxes shall be third party certified. Self certification is not
acceptable
Terminal blocks shall be channel (rail) mounted,
strip type, with tubular box clamp connector and compression bar or yoke for wire termination.
As a minimum, the thickness of the terminals shall be 5 mm or higher.
Multi-deck and spring type terminal blocks are not acceptable
Terminals and terminal block accessories (e.g., DIN rail mounting brackets for electrical
insulation, busbar support blocks, end brackets, etc.) shall be fire retardant in accordance with
UL 94, V0.
Terminals and accessories shall be made of halogen free, high strength material such as
polyamide or equivalent. Brittle materials such as melamine shall not be used.
Terminal strip spacing shall allow ample room for plastic wire ducts and permit training and lacing Min. 60 mm spacing between TB to JB sides and TB to ducts
of cables, and fanning of individual
2-Aug-15
000
Vendor compliance
comply
comply
comply
comply
comply
comply
comply
comply
Captive screws used in lieu of captive clamps as per latest SAES J
902
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply
comply