ExampleofConcreteAnchorBoltDesignCalculationPart1:DeterminingSteelStrengthofAnchorBoltinTension
ExampleofConcreteAnchorBoltDesignCalculationPart3:DeterminingPulloutStrengthofAnchorinTension
PrintthisPost

ExampleofConcreteAnchorBoltDesignCalculation
Part2:DeterminingConcreteBreakoutStrengthof
Translate
AnchorinTension
Wewilldiscusshowtocalculatethe
TensileStructures
concretebreakoutstrengthaccording
totheACI318codeinthispartofthe EminentManufacturer&SupplierofTensileStructures@BestPrice.
concreteanchorfoundationbolt
designcalculationexample.Please
referpart1ofthecalculationtounderstandthedesignproblemstatementandthecalculationsfor
theanchorboltmaterialsstrength.

IfyourefertheFig.1andtheFig.2oftheproblemstatementthenitwillcleartoyouthatthe
distancebetweentwosurroundinganchors(inourcaseitis6inch)islessthanthreetimesthe
effectiveembedmentdepth(inourcaseitis10inch).So,asperACIcodes,theanchor
arrangementcanbetermedasgroupandtheACIformulaforcalculatingtheconcretebreakout
strengthfortheanchorgroupis:
Ncbg=(ANc/ANco)ec,Ned,Nc,Ncp,NNb..D5

Where,
Strengthreductionfactorforbreakoutstrengthanditsvaluefornonreinforcementintension
is0.70
ANcTotalprojectedareaforthegroupofanchorsofthefailuresurfaceasapproximatedbya
rectanglewithedgesboundedby1.5hef(1.5*10=15inchinourcase)andthefreeedgesofthe
concretefromthecenterlineoftheanchors.Confused?Youwillbeclearerwhilecalculatingitlittle
later.
hefEffectiveembedmentdepthofanchor(inourcaseitis10inch).
ANcoTotalprojectedfailureareaapproximatedbyasquareboundedby1.5hef(1.5*10=15inch
inourcase)fromthecenterlineoftheanchorsatallthesides.
ec,NModificationfactorfortheanchorgrouploadedeccentricallyintension,inourcasethereis
READPREVIOUSPOST:
noeccentricloading,soec,N=1.

ExampleofConcreteAnchorBoltDesignCalculationPart1:

DeterminingSteelStrengthofAnchorBoltinTension
ed,NModificationfactorforedgeeffectfortheanchorgroupintension,wewillcalculateitlater.

Anchorboltsareusedextensivelyasfoundationbolts
c,NModificationfactorbasedonthepresenceandabsenceofcrackintheconcrete,wewill
calculateitlater.
forrotatingequipmentslikemachinesandstructural
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart2determiningconcretebreakoutstrengthofanchorinte

1/6

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart2BreakoutStrengthinTension
forrotatingequipmentslikemachinesandstructural
membersliketowers.TheAmerican...
cp,NModificationfactorforpostweldtypesofanchor.Forcastinplaceanchor
cp,N=1

NbBasicconcretebreakoutstrengthforasingleanchorintension,wewillcalculateitlater.

CalculationofANc
Beforegoingtothecalculationpleaserefertheplanviewoftheanchorarrangementasbelow:

Fig.2.1:AnchorBoltPlanforcalculatingAnc

ANC=Areaofthesquareshownindottedline
=(15+6+5)*(15+6+5)=676SquareInch

CalculationofANco
Beforegoingtothecalculationpleaserefertheplanviewoftheanchorarrangementasbelow:

http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart2determiningconcretebreakoutstrengthofanchorinte

2/6

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart2BreakoutStrengthinTension

Fig.2.2:AnchorBoltPlanforcalculatingAnco

ANC=Areaofthesquareshownindottedline
=(15+15)*(15+15)=900SquareInch

Calculationofed,N
If,Ca,min(minimumdistancesbetweentwoanchors,6inchinourcase)is
lessthan1.5timesthehef(1.5*10=15inchinourcase)then
ed,N=0.7+(0.3*Ca,min)/(1.5*hef)
=0.7+(0.3*6)/(1.5*10)
=0.82

Calculationofc,N
Accordingtothecodethevalueofc,N=1whereconcretecrackislikelytooccur.

CalculationofNb
Nb=kchef1.5fcD7
Where,
Kcafactorwhichhasvalueof24forcastinconcrete.
Afactorrelatedtothereducedmechanicalpropertiesofconcrete,fornormalweightconcrete=1
hefEffectiveembedmentdepthofanchor(inourcaseitis10inch).
fcSpecifiedcompressivestrengthoftheconcrete,inourcasefc=4000psi(referproblemstatement)
So,byputtingthevalueinD7weget:
Nb=24*1*10^1.5*4000^0.5
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart2determiningconcretebreakoutstrengthofanchorinte

3/6

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart2BreakoutStrengthinTension

=48000lb

Now,byputtingallthevaluesinD5wegettheConcretebreakoutstrengthfortheanchorgroup
Ncbg=(ANc/ANco)ec,Ned,Nc,Ncp,NNb
=0.70*(676/900)*1*0.82*1*1*48000
=20694.6131lb
So,finallywegottheconcretebreakoutstrengthoftheanchorgroupintensionas20694.6131lb.Inthenextpart(Part3)of
thefoundationanchorboltdesigncalculationexample,wewilldiscussaboutcalculatingtheconcretepulloutforcein
tension.

FastrackBlackAnalogWatch
Rs.2,995.00 ShopNow&GetExtraCashback.
Fastrack

AboutShibashisGhosh
Shibashisisamechanicaldesignengineerbyprofessionandwriter/bloggerbypassion.Hehasworkedin
variousdesignprojectsinautomobile,powerplantandheavyearthmovingequipmentdomainsince2005.
Inhissparetimeapartfrommaintainingthisblog,heenjoyinvestingtimebuildinghisfirstRCplane
ReadMore>>
Findmoreaboutmeon:

1 2

More

Likethis:

Like
Bethefirsttolikethis.

Related

ExampleofConcreteAnchorBoltDesign
CalculationPart6:DeterminingConcrete
BreakoutStrengthofAnchorinShear
In"Engineeringdesign"

ExampleofConcreteAnchorBoltDesign
CalculationPart3:DeterminingPullout
StrengthofAnchorinTension
Pleaserefertheproblemstatementandthe
part1,part2ofthiscastinplaceconcrete
anchorboltdesigncalculationexampleso
thatyouwillbeinphasewiththispart
(part3)ofthecalculation.Herewewill
In"Engineeringdesign"
calculatethepulloutstrengthofthe

ExampleofConcreteAnchorBoltDesign
CalculationPart4:DeterminingSideface
BlowoutStrengthofAnchorinTension
Inthispartwewillcalculatethesideface
blowoutstrengthoftheconcreteanchor
accordingtotheACI318AppendixDcodes
andalsoconsolidatetheresultsofthe
differenttypesofanchorstrengthsin
In"Engineeringdesign"
tensionwehavecalculatedsofar.Please

1comment

1.
ashe

August19,2015at1:58am(UTC5.5)
accordingtothecommentary,ca,ministheminimumedgedistance,nottheminimumdistancebetweenboltsasyou
statedabove.

LeaveaReply

http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart2determiningconcretebreakoutstrengthofanchorinte

4/6

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart3PullOutStrengthinTension

Home

MechGuru
Categories
Engineeringdesign
ManufacturingEngineering
FluidEngineering
EngineeringCalculator
MaterialEngineering
HowitWorks
ThermalEngineering
EngineeringMath
EngineeringSoftwares
VehicleDesign
AppliedMath
Electronics
Advertise

Translate

ExampleofConcreteAnchorBoltDesignCalculationPart2:DeterminingConcreteBreakoutStrengthofAnchorin
Tension
ExampleofConcreteAnchorBoltDesignCalculationPart4:DeterminingSidefaceBlowoutStrengthofAnchorin
Tension
PrintthisPost

ExampleofConcreteAnchorBoltDesignCalculation
Part3:DeterminingPulloutStrengthofAnchorin
Tension
Pleaserefertheproblemstatementandthepart
ZIMMScrewJackSystems
1,part2ofthiscastinplaceconcreteanchor
boltdesigncalculationexamplesothatyouwill Yourcapablepartnerwith35years.ExperienceinScrewJackTechnology
beinphasewiththispart(part3)ofthe
calculation.Herewewillcalculatethepullout
strengthoftheconcreteanchoraccordingtotheACI318AppendixDcodes.

WhatisAnchorPulloutStrength?
Asthenamesuggests,itistheforcerequiredtouprootaanchoroutoftheconcrete.

Calculation
AccordingtoACIcodes,thepulloutstrengthofthegroupofanchorsisgivenby
Npn=8nc,PAbrgfc..D14

Where,
Strengthreductionfactorforpulloutstrengthanditsvaluefornon
reinforcementintensionis0.70
c,PModificationfactorforpulloutstrengthbasedonthepresenceof
concretecracks,fortheconcretewithcracksatserviceloadlevelc,P=1.

READPREVIOUSPOST:

ExampleofConcreteAnchorBoltDesignCalculationPart2:
DeterminingConcreteBreakoutStrengthofAnchorinTension

Wewilldiscusshowtocalculatetheconcretebreakout
strengthaccordingtotheACI318codeinthispartof...

nNumberofanchorbolts,inourcasen=4.
AbrgNetbearingareaoftheheadofanchorboltinsquareinch,inour
caseAbrg=0.654Squareinch.
fcTheconcretesspecifiedcompressivestrengthinpsi,inourcase
fc=4000psi.
So,byputtingallthevaluesinD14,wegetthepulloutstrengthoftheanchorgroupas
Npn=0.7*8*4*1*0.654*4000lb
=58598.4lb
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart3determiningpulloutstrengthofanchorintension/

1/3

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart4BlowoutStrengthinTension

Home

MechGuru
Categories
Engineeringdesign
ManufacturingEngineering
FluidEngineering
EngineeringCalculator
MaterialEngineering
HowitWorks
ThermalEngineering
EngineeringMath
EngineeringSoftwares
VehicleDesign
AppliedMath
Electronics
Advertise

Translate

ExampleofConcreteAnchorBoltDesignCalculationPart3:DeterminingPulloutStrengthofAnchorinTension
ExampleofConcreteAnchorBoltDesignCalculationPart5:DeterminingSteelStrengthofAnchorBoltinShear
PrintthisPost

ExampleofConcreteAnchorBoltDesignCalculation
Part4:DeterminingSidefaceBlowoutStrengthof
AnchorinTension
Inthispartwewillcalculatethesideface
blowoutstrengthoftheconcreteanchor
accordingtotheACI318AppendixDcodesand
alsoconsolidatetheresultsofthedifferenttypes
ofanchorstrengthsintensionwehave
calculatedsofar.
Pleaserefertheproblemstatementandthepart1,part2,part3ofthiscastinplaceconcreteanchorboltdesigncalculation
examplesothatyouwillbeinphasewiththispart(part4)ofthecalculation.
WhatisSidefaceBlowOutStrength?
Insimpleterm,itisthefailureoftheconcreteduetotheclosenessofananchorboltwiththesidesurfaceoftheconcrete
foundation.Whentheanchorboltistooclosetothesidethenthepossibilitiesaretherethatbeforebreakingoutthetop
concretesurface,thesidesurfacegetbroken.Whilecalculatingsidefaceblowoutthedepthoftheanchorboltandthe
distanceoftheanchorfromtheclosestedgeareconsidered.

Calculation

READPREVIOUSPOST:

ExampleofConcreteAnchorBoltDesignCalculationPart3:
DeterminingPulloutStrengthofAnchorinTension

AccordingtoACIcodes,youneedtocalculatethesidefaceblowoutonlyfortheanchorswhichhasthedistancefromthe
Pleaserefertheproblemstatementandthepart1,part
edgelesserthan0.4timesthedepthoftheanchor,or
2ofthiscastinplaceconcreteanchorboltdesign
calculationexample...
Ca1<0.4*hef4.1
Where,
Ca1Minimumdistancefromtheanchortothefoundationedge(inourcaseitis5inch)
hefEffectiveembedmentdepthofanchor(inourcaseitis10inch).
So,fromequation4.1,0.4**hefis4whichislessthanCa1soweneedtocalculatesidefaceblowoutstrengthforthis
example.
SummaryofCalculatedStrengthValuesinTension
Throughthepart1,Part2,part3,andthispartwehavecomeoutwiththefollowingstrengthvalues:
Nominalmaterialstrengthfortheanchors(Nsa)=75150lb
Concretebreakoutstrengthfortheanchorgroup(Ncbg)=20694.6131lb
Pulloutstrengthoftheanchorgroup(Npn)=58598.4lb
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart4determiningsidefaceblowoutstrengthofanchorinten

1/3

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart4BlowoutStrengthinTension

Sidefaceblowoutstrength=NA
Outofthesethreestrengthvaluesthesmallestonewillbethedesign
strength.
So,thedesignstrengthintension=20694.6131lb
Ifyourefertheproblemstatementforthisfoundationanchorboltdesign
calculationexamplethenyoucanobservethattensileload(20000lb)
appliedislowerthanthecalculateddesignstrengthintension(20694.6131
lb),so,thedesignissafeundertensileload.
Inthenextpart(Part5),wewilldiscusscalculatingthematerielstrength
orsteelstrengthinshear.

HdfcLifeRetirementPlan
Guaranteed*ReturnswithNOIntermediaryChargesBuy
OnlineNow

AboutShibashisGhosh
Shibashisisamechanicaldesignengineerbyprofessionandwriter/bloggerbypassion.Hehasworkedin
variousdesignprojectsinautomobile,powerplantandheavyearthmovingequipmentdomainsince2005.
Inhissparetimeapartfrommaintainingthisblog,heenjoyinvestingtimebuildinghisfirstRCplane
ReadMore>>
Findmoreaboutmeon:

More

Likethis:

Like
Bethefirsttolikethis.

Related

ExampleofConcreteAnchorBoltDesign
CalculationPart1:DeterminingSteel
StrengthofAnchorBoltinTension
In"Engineeringdesign"

ExampleofConcreteAnchorBoltDesign
CalculationPart3:DeterminingPullout
StrengthofAnchorinTension
Pleaserefertheproblemstatementandthe
part1,part2ofthiscastinplaceconcrete
anchorboltdesigncalculationexampleso
thatyouwillbeinphasewiththispart
(part3)ofthecalculation.Herewewill
In"Engineeringdesign"
calculatethepulloutstrengthofthe

ExampleofConcreteAnchorBoltDesign
CalculationPart7:DeterminingPryout
StrengthofAnchorinTension
Inthispartoftheconcreteanchorbolt
designcalculationexamplewewillcalculate
theconcretepryoutstrengthundershear
forceappliedtothestructuralcastinplace
foundationanchorboltofthecolumnshown
In"Engineeringdesign"
intheFigure1and2ofthePart1ofthis

LeaveaReply
Enteryourcommenthere...

Anouncement
ScienceorEngineeringGraduate?Writefor
mechGuru

Subscribe

Togetthelatestpostdirectlytoyouremailbox,Enter
youremailaddress:

Subscribe

http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart4determiningsidefaceblowoutstrengthofanchorinten

2/3

12/01/2016

ACI318AppendixDConcreteAnchorFoundationBoltDesignCalculationswithExampleCalculatingSteelStrengthinShear

Home

MechGuru
Categories

Translate

Engineeringdesign
ManufacturingEngineering
FluidEngineering
EngineeringCalculator
MaterialEngineering
HowitWorks
ThermalEngineering
EngineeringMath
EngineeringSoftwares
VehicleDesign
AppliedMath
Electronics
Advertise

ExampleofConcreteAnchorBoltDesignCalculationPart4:DeterminingSidefaceBlowoutStrengthofAnchorin
Tension
HowtoShowEnergyConservationsbyCalculatingtheKineticandPotentialEnergy
PrintthisPost

ExampleofConcreteAnchorBoltDesignCalculation
Part5:DeterminingSteelStrengthofAnchorBoltin
Shear
Inthispart(part5),wewillseetheconcrete
anchorboltdesigncalculationexamplefor
calculatinganchormaterial(steel)strengthin
shearaccordingtotheACI318appendixD
codes.Butbeforethat,pleasegothroughthe
problemstatementandpart1,part2,part3andpart4ofthisseries.

Upto Rs.50 cashback

Calculation

READPREVIOUSPOST:

ExampleofConcreteAnchorBoltDesignCalculationPart4:
DeterminingSidefaceBlowoutStrengthofAnchorinTension

TheformulafordeterminingthesteelstrengthinsheargivenintheAmericanConcreteInstitutecodeis:
Steelstrengthinshear,Nsa=nAse,Nfuta..D19
Where,

Inthispartwewillcalculatethesidefaceblowout
strengthoftheconcreteanchoraccordingtotheACI
318Appendix...

Strengthreductionfactoranditsvalueforductileanchorboltinshearthevalueofitis0.65
NsaNominalshearstrengthofthegroupofanchorinlb
nTotalanchornumberinthegroup,inourcasethevalueis4
Ase,NEffectivecrosssectionalareaofasingleanchor,thevalueofitforthe0.75inchanchorboltis0.334squareinch.
futaSpecifiedtensilestrengthforasingleanchor(tobeobtainedfrom
manufacturerscatalog)inpsi,inourcasethevalueis75000psi.

Now,byputtingthevaluesintheequationD19explainedabove,wecan
obtainthevalueofthesteelstrengthforthegroupofanchoris:
Nsa=0.65*4*0.334*75000=65130lb

Youmighthavealreadyobservedthatonlydifferencebetweencalculating
thecastinplaceanchorboltmaterialstrengthinshearandintensionisthe
strengthreductionfactor.Forshearitis0.65andfortension0.75.Also,pleaserememberthatinboththecasesweused
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart5determiningsteelstrengthofanchorboltinshear/

1/3

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleAccordingtoACI318AppendixDBreakoutStrengthinShear

Home

MechGuru
Categories
Engineeringdesign
ManufacturingEngineering
FluidEngineering
EngineeringCalculator
MaterialEngineering
HowitWorks
ThermalEngineering
EngineeringMath
EngineeringSoftwares
VehicleDesign
AppliedMath
Electronics
Advertise

HowtoShowEnergyConservationsbyCalculatingtheKineticandPotentialEnergy
Advantages,DisadvantagesandApplicationsofDifferentTypesofCompressors
PrintthisPost

ExampleofConcreteAnchorBoltDesignCalculation
Part6:DeterminingConcreteBreakoutStrengthof
AnchorinShear
Beforedivingintotheconcreteanchorbolt
designcalculationexampleforcalculating
anchorbreakoutstrengthinshear,pleasego
5% Cashback
throughtheproblemstatementandpart1,part
2,part3,part4andpart5ofthisseries.The
calculationexerciseiscarriedoutaccordingtotheACI318appendixDcodes.

on Rs.50

Calculation
Thecodegivesthefollowingformulaforfindingoutthebreakoutstrengthinshearforagroupofanchorbolts:
Vcbg=(AVc/AVco)ec,Ved,Vc,Vcp,VVb..D22

Where,
Strengthreductionfactorforbreakoutstrengthanditsvaluefornonreinforcementintensionis0.70
Avcprojectedconcretefailureareaofthegroupofanchors,forcalculationofstrengthinshear(ininch2)asapproximated
byarectanglewithedgesboundedby1.5*Ca1(1.5*5=7.5inchinourcase)andthefreeedgesoftheconcretefromthe
centerlineoftheanchors.Wewillcalculateitlittlelater.
Ca1Distancefromthecenterofananchorshafttotheedgeofconcreteinonedirection(ininch).ReferFig.1below.
AvcoTotalprojectedshearfailureareaapproximatedbyasquareboundedby1.5*Ca1(1.5*5=7.5inchinourcase)from
thecenterlineofaanchoratallthesides.Wewillcalculateitlittlelater.
ec,VModificationfactorfortheanchorgrouploadedeccentricallyinshear,inourcasethereisnoeccentricloading,so
ec,V=1.
ed,VModificationfactorforedgeeffectfortheanchorgroupinshear,wewillcalculateitlater.
c,VModificationfactorbasedonthepresenceandabsenceofcrackintheconcrete,inourcasevalueofit=1..
cp,VModificationfactorforpostweldtypesofanchor.Forcastinplaceanchorcp,V=1
VbBasicconcretebreakoutstrengthforasingleanchorinshear,wewillcalculateitlater.

CalculationofAVc
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart6determiningconcretebreakoutstrengthofanchorinsh

1/6

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleAccordingtoACI318AppendixDBreakoutStrengthinShear

Fig.1:ShowingCa1forcalculatingAvcandAvcoforAnchorGroup

Fig.2:AnchorBoltElevationforcalculatingAvc

Refertheabovetwofigure(Fig.1andFig.2),itshouldbeclearbynowthat
AVC=16.5*(5+6+16.5)=453.75inch2

CalculationofAVco

http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart6determiningconcretebreakoutstrengthofanchorinsh

2/6

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleAccordingtoACI318AppendixDBreakoutStrengthinShear

Translate

Fig.3:AnchorBoltElevationforcalculatingAvco
Byreferringtheabovefigure(Fig.3),wecancalculate
Avco=16.5*(16.5+16.5)=544.5inch2
Calculationofed,V
ForCa2<1.5Ca1
ed,V=0.7+(0.3*Ca2)/(1.5*Ca1)=0.7+(0.3*5)/(1.5*11)=0.79

Where,
Ca2MinimumconcreteedgedistancefromanchorperpendiculartoCa1.

CalculationofVb
Vb=(7*da*[le/da]0.2)**fc*(Ca1)1.5..D24

Where,
da=Diameteroftheanchorboltininch.,inourcaseitis0.75inch.Rememberwehavestartedwiththe0.75inchanchorin
thepart1ofthiscalculation.
le=Lengthoftheanchorinsertedinsidetheconcreteininch.Inourcaseitis10inch.
=Afactorrelatedtothereducedmechanicalpropertiesofconcrete,fornormalweightconcrete=1.
Ca1=wealreadyknowitfromtheFig.1.Itsvalueis11inch.
READPREVIOUSPOST:
fc=Specifiedcompressivestrengthoftheconcrete,inourcasefc=4000psi(referproblemstatementofpart1).

HowtoShowEnergyConservationsbyCalculatingtheKinetic

http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart6determiningconcretebreakoutstrengthofanchorinsh

3/6

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleAccordingtoACI318AppendixDBreakoutStrengthinShear
HowtoShowEnergyConservationsbyCalculatingtheKinetic
andPotentialEnergy

So,byputtingallthevalues,theaboveequation(D24)becomes

WhatisEnergy?Energyisthecapacityofanobjector
asystemtodoworkonsurroundingobjectsor...

Vb=(7*0.75*[10/0.75]0.2)*1*(4000)*111.5
=23482.02lb

Now,fromtheequationD22,afterputtingallthevaluesatrighthandside,
Vcbg=(AVc/AVco)ec,Ved,Vc,Vcp,VVb
=0.7*(453.75/544.5)*1*0.79*1*1*23482.02lb
=10821.297lb

TheconcretebreakoutstrengthinshearfortheanchorboltgroupaccordingtotheACIcodesiscalculatedas10821.297lb.
Thenextpart(Part7)willtalkaboutConcretePulloutStrengthinShear.

PittsburghPoloClubChronograph...
Rs.299.00 ShopNow&GetExtraCashback.
PittsburghPoloClub

AboutShibashisGhosh
Shibashisisamechanicaldesignengineerbyprofessionandwriter/bloggerbypassion.Hehasworkedin
variousdesignprojectsinautomobile,powerplantandheavyearthmovingequipmentdomainsince2005.
Inhissparetimeapartfrommaintainingthisblog,heenjoyinvestingtimebuildinghisfirstRCplane
ReadMore>>
Findmoreaboutmeon:

2 2

More

Likethis:

Like
Bethefirsttolikethis.

Related

ExampleofConcreteAnchorBoltDesign
CalculationPart4:DeterminingSideface
BlowoutStrengthofAnchorinTension
Inthispartwewillcalculatethesideface
blowoutstrengthoftheconcreteanchor
accordingtotheACI318AppendixDcodes
andalsoconsolidatetheresultsofthe
differenttypesofanchorstrengthsin
In"Engineeringdesign"
tensionwehavecalculatedsofar.Please

ExampleofConcreteAnchorBoltDesign
CalculationPart2:DeterminingConcrete
BreakoutStrengthofAnchorinTension
In"Engineeringdesign"

ExampleofConcreteAnchorBoltDesign
CalculationPart7:DeterminingPryout
StrengthofAnchorinTension
Inthispartoftheconcreteanchorbolt
designcalculationexamplewewillcalculate
theconcretepryoutstrengthundershear
forceappliedtothestructuralcastinplace
foundationanchorboltofthecolumnshown
In"Engineeringdesign"
intheFigure1and2ofthePart1ofthis

2comments

1.
asad

September7,2013at10:48am(UTC5.5)
nycjob

2.
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart6determiningconcretebreakoutstrengthofanchorinsh

4/6

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart7PryoutStrengthinShear

Home

MechGuru
Categories
Engineeringdesign
ManufacturingEngineering
FluidEngineering
EngineeringCalculator
MaterialEngineering
HowitWorks
ThermalEngineering
EngineeringMath
EngineeringSoftwares
VehicleDesign
AppliedMath
Electronics
Advertise

Translate

HowPracticalaWaterPoweredCarreallyis
ExampleofConcreteAnchorBoltDesignCalculationPart8:InteractionofTensileandShearForces
PrintthisPost

ExampleofConcreteAnchorBoltDesignCalculation
Part7:DeterminingPryoutStrengthofAnchorinTension
Inthispartoftheconcreteanchorboltdesign
calculationexamplewewillcalculatethe
concretepryoutstrengthundershearforce
appliedtothestructuralcastinplacefoundation
anchorboltofthecolumnshownintheFigure1
and2ofthePart1ofthisdesigncalculationseries.

WhatisConcretePryoutStrength?
Thisissomethingrelatedtothecomingoutoftheshortandstiffanchorsbybreakingorchippingtheconcreteatthedirection
oppositetotheappliedshearforcetothecolumn.
DesignCalculation
ThecodeACI318AppendixDgivesthefollowingequation:
Vcpg=kcpNcbgD31
Where,
Strengthreductionfactorforpryoutstrengthanditsvaluefornonreinforcementintensionis0.70
VcpgPryoutstrength
kcpFactor,whichhasvalue=2fortheanchorlongerthan2.5inch.
NcbgConcretebreakoutstrengthintension(=20694.6131lb,ReferPart2)fortheanchorgroup.

Now,byputtingallthevalueswegetthepryoutstrength,
Vcpg=28972.45lb
SummaryofCalculatedStrengthValuesinShear

READPREVIOUSPOST:

HowPracticalaWaterPoweredCarreallyis

Waterfueledcar?Well,itdoesexistorevenbetter,you
canconvertyourcartorunonwaterby...

Throughthepart5,Part6,andthispartwehavecomeoutwiththe
followingshearstrengthvalues:
Nominalmaterialstrengthinfortheanchors(Vsa)=65130lb
Concretebreakoutstrengthfortheanchorgroup(Vcbg)=10821.297
lb
Pryoutstrengthoftheanchorgroup(Vpn)=28972.45lb
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart7determiningpryoutstrengthofanchorintension/

1/4

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart7PryoutStrengthinShear

Outofthesethreestrengthvaluesthesmallestonewillbethedesign
strength.
So,thedesignstrengthinshear=10821.297lb
Fromtheproblemstatement(part1),youcanobservethatappliedfactoredshearforcetothecolumn=2300lb.
Since,designstrengthinshearismuchlowerthanthefactoredappliedshearforce,so,theanchorboltsaresafeundershear
loading.
Inthenextpart(Part8)ofthisconcreteanchorfoundationboltdesigncalculationexamplewewillseetheinteractionof
tensileandshearforcesaccordingtotheACI318D.

HdfcLifeClick2Retire
NoAllocationCharges.MaxCapitalGuarantee*of135%with
TaxBenefit

AboutShibashisGhosh
Shibashisisamechanicaldesignengineerbyprofessionandwriter/bloggerbypassion.Hehasworkedin
variousdesignprojectsinautomobile,powerplantandheavyearthmovingequipmentdomainsince2005.
Inhissparetimeapartfrommaintainingthisblog,heenjoyinvestingtimebuildinghisfirstRCplane
ReadMore>>
Findmoreaboutmeon:

More

Likethis:

Like
Bethefirsttolikethis.

Related

ExampleofConcreteAnchorBoltDesign
CalculationPart1:DeterminingSteel
StrengthofAnchorBoltinTension
In"Engineeringdesign"

ExampleofConcreteAnchorBoltDesign
CalculationPart4:DeterminingSideface
BlowoutStrengthofAnchorinTension
Inthispartwewillcalculatethesideface
blowoutstrengthoftheconcreteanchor
accordingtotheACI318AppendixDcodes
andalsoconsolidatetheresultsofthe
differenttypesofanchorstrengthsin
In"Engineeringdesign"
tensionwehavecalculatedsofar.Please

ExampleofConcreteAnchorBoltDesign
CalculationPart3:DeterminingPullout
StrengthofAnchorinTension
Pleaserefertheproblemstatementandthe
part1,part2ofthiscastinplaceconcrete
anchorboltdesigncalculationexampleso
thatyouwillbeinphasewiththispart
(part3)ofthecalculation.Herewewill
In"Engineeringdesign"
calculatethepulloutstrengthofthe

2comments

1.
ThilakeshKumar

April30,2012at10:27am(UTC5.5)
ifanybodydesigninanchorboltmodelplzuploadit.wewantsomemodels

2.
ThilakeshKumar

April30,2012at10:28am(UTC5.5)
IamlookingatrationaldesigncriteriaforAnchorbolts
1.Edgedistance
2.
Embedmentlength
3.Sleeverequirements
4.Projectionofanchorabove
groutcalculations
http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart7determiningpryoutstrengthofanchorintension/

2/4

12/01/2016

ConcreteAnchorFoundationBoltDesignCalculationswithExampleasperACI318AppendixDPart8InteractionofTensileandShearForces
Translate

Home

MechGuru
Categories
Engineeringdesign
ManufacturingEngineering
FluidEngineering
EngineeringCalculator
MaterialEngineering
HowitWorks
ThermalEngineering
EngineeringMath
EngineeringSoftwares
VehicleDesign
AppliedMath
Electronics
Advertise

ExampleofConcreteAnchorBoltDesignCalculationPart7:DeterminingPryoutStrengthofAnchorinTension
DifferencebetweenDMADVandDMAIC
PrintthisPost

ExampleofConcreteAnchorBoltDesignCalculation
Part8:InteractionofTensileandShearForces
Inthispartoftheconcreteanchorboltdesign
calculationexamplewewillseetheinteraction
oftensileandshearforcesforthestructuralcast
inplacefoundationanchorboltofthecolumn.
PleaserefertheFigure1and2ofthePart1of
thisanchordesignseries.
WhattheACI318Codessays

READPREVIOUSPOST:

ExampleofConcreteAnchorBoltDesignCalculationPart7:

If,thefactoredshearload(2300lbinourcase,referpart1)>0.2*designstrengthinshear(10821.297lbinourcase,refer
DeterminingPryoutStrengthofAnchorinTension
part7)

Inthispartoftheconcreteanchorboltdesign
And,thefactoredtensileload(20000lbinourcase,referpart1)>0.2*designstrengthintension(20694.6131lbinour
calculationexamplewewillcalculatetheconcretepry
case,referpart4)
outstrengthunder...
Then,
(factoredshearload/designstrengthinshear)+(factoredtensileload/designstrengthintension)
<=1.2..eq.8

Forourcase,thelefthandsideoftheeq.8becomes:
(2300/10821.297)+(20000/20694.613)=1.181,whichislessthan1.2,so,wecanconcludethattheanchorboltdesignis
safeundertheinteractionoftensileandshearforces.

ZIMMScrewJackSystems
Yourcapablepartnerwith35years.ExperienceinScrew
JackTechnology

AboutShibashisGhosh
Shibashisisamechanicaldesignengineerbyprofessionandwriter/bloggerbypassion.Hehasworkedin
variousdesignprojectsinautomobile,powerplantandheavyearthmovingequipmentdomainsince2005.
Inhissparetimeapartfrommaintainingthisblog,heenjoyinvestingtimebuildinghisfirstRCplane
ReadMore>>
Findmoreaboutmeon:

More

Likethis:

http://blog.mechguru.com/machinedesign/exampleofconcreteanchorboltdesigncalculationpart8interactionoftensileandshearforces/

1/3

Você também pode gostar