Você está na página 1de 21

BM11S E-light+RF+LASER

Multinational beauty machine

User manual

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
2

Warning
Dear user:
Thanks for using our company's products, in order to fully make use of the products, we
sincerely suggests follow:
Please read the instruction in detail and keep it well for further reading and
consulting.
Please follow the instruction to fit and operate the machine correctly.
Please do not remove and change any accessories of the machine.
It forbids others to open and remove the mainframe except the authorized people
in the company.
It forbids others to change and maintain the machine except the professional
people.
Please contact us if there is any trouble during operation.

This product does not belong to medical, please dont use for disease treatment!

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
3

Contents
Chapter 1 Product structure..................................................................................................................3
Chapter 2 Accessories list..................................................................................................................... 5
Chapter 3 Product informaion.............................................................................................................. 5
Chapter 4 Installation.............................................................................................................................. 6
Chapter 5 Operation.................................................................................................................................8
Chapter 6 Treatment.............................................................................................................................. 13
6.1 Principle........................................................................................................................................... 13
6.2 Hand-piece and Application......................................................................................................... 13
6.3 Attentions before the treatment................................................................................................... 14
6.4 Hair removal....................................................................................................................................15
6.5 Skin rejuvenation........................................................................................................................... 16
6.6 Pigmentation Therapy................................................................................................................... 16
6.7 Vascular Therapy...........................................................................................................................17
6.8 Acne Therapy..................................................................................................................................18
6.9 Wrinkle removal..............................................................................................................................18
6.10 After Treatment Care...................................................................................................................19
Chapter 7 Service manual....................................................................................................................19
Chapter 8 Maintenance......................................................................................................................... 20

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
4

Caution
1. When you received the new machine, please open it work one minute
(enjoin from the machine working).
2. Shut down the machine.
3. Affusion water again
4. Anew Open the machine
When the water stream very well, then you can let the machine working.

Chapter 1 Product structure

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
5

Chapter 2 Accessories

Chapter 3 Product informaion

3.1 Application
E light application:
1. Therapy acne
2. Reduction of vascular lesions
3. Reduction of pigmented lesions
4. Skin rejuvenation
5. Permanent hair removal
6. Wrinkle removal
RF application:

1.

Skin lifting, tightening, and whitening

2.

New collagen stimulation and production

3.

Removes fine lines and wrinkles

4.

Facial remodeling and body contouring

5.

Visibly minimize pores

6.

Circumference and cellulite reduction

7.

Body Shaping areas: abdomen, buttocks, thighs, neck, upper arms.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
6

Laser application:

1. 1064nm Wavelength: Remove black and dark blue tattoo pigments, such as tattoos,
eyebrows, dark color around the eyes, freckle, age spot etc.
2. 532nm Wavelength: Remove red and brown tattoos and redmark.

3.2 Specification:
Wavelength

430/530/560/580/640-1200(nm)

E light Handpiece

1 piece with 5 filters

RF handle

1 piece with 3 tips

Laser handle

1 piece with 2 tips(1064 and 532)

Cooling system

semiconductor+air+water+cooling gel

IPL light energy

1-50(J/cm)

Pulse Duration

1-10ms

Pulse NO.

1--6

Skin cooling

-4c-10c

Display

10.4"color touch screen

Output power

2000W

RF frequency

10MHZ

Laser frequency

1-6HZ

Voltage

110V,50HZ or 220V,60HZ

Machine Size

(L*W*H):42cm*38cm*90cm

Net weight

56kg

Gross weight

91kg

Package size

65cm*63cm*111cm

Color

white & gray

Chapter 4 Installation

4.1 The process of installation includes:


1. Unpacking the device.
2. Staying the device for one day, in order to avoid destruction by high humidity during
long distant transportation.
3.

Assembly of its components and ensure that all connections are firmly inplace.

4.

Fill the water tank with distilled water only.

5.

Connect the power supply.

6.

Switch on the device and test all functions / parameters of the system.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
7

4.2 Installation
1)

Installation treatment handpiece, please follow the figure,Plug

the handpiece

connector firmly and properly to avoid the water circulation problem.

Figure 4.1
1)

Unscrew the Infusion hole cap and the overflow hole cap. (According to the following figure)

Figure 4.2
2)

Infuse distilled water until the water overflow the overflow hole.
Overflow hole

Figure 4.3
3)

Ensure that the key is in the off position and that the emergency cut off button is not engaged. If
it is engaged, release it by rotating the button towards the direction of the arrow indicator.

4)

Attach the power cord .

5)

Switch the circuit breaker to the On position.

Figure 4.4

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
8

6)

Switch the unit on by inserting the key and turning it in a clockwise direction. At this time water
circulation and the cooling system starts automatically.

7)

Observe whether water circulation runs well or not. After cooling system runs for at least 1
minute, the water slide into the cooling system and then turn off the power.

8)

Then switch on the system. It means you can fully assemble system with handpiece, screw on
the infusion cap.

9)

According to the following figure changeable of the various wavelength by 430,530,560,


580,640~1200nm filter for spot size: 12*30mm.

slot

Figure 4.5
10) When replace water
1. Drain the remaining water which contains in the handle. Pay particular attention as not to
spill any water on the electronic terminals. Wipe off any spilled water with a soft absorbent
cloth.
2. Replace water every 1-2 months.

CAUTION
1.
2.
3.
4.

Only distilled water is to be used in the cooling system.


When using the system for the first time, rinse the cooling system with distilled water.
Ensure that the water level is adequate before treatment to prevent over heating.
Distilled water is added periodically specially when working in warmer climates and
when the treatment handpiece are changed often.
5. Make sure that the treatment head is firmly secured .

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
9

Chapter 5 Operation

WARNING
1. WARNING: HIGH VOLTAGE: please ensure that all panels are secured prior to
operation.
2. Place the treatment head on its support when on standby / simmer mode.
3. All personnel in the treatment room must wear the protective filteredglasses supplied.
4. Make sure the patient is wearing the opaque protective goggles prior to treatment
5. Avoid looking directly into the intense light during the treatmenteven if you are
wearing the protection glasses.
6. Do not point the treatment head outside the treatment field

1Select Therapy Program


Turn on the key switch of the machineenter Select Therapy Programs interface (as Fig.1).
Select the treatment model to enter the interface of relevant treatment.

Fig.1

2Treatment Interface (E-light)

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
10

Fig.2

After entering the interface of Treatment interface (as shown in Fig.2), press Ready to trigger
the handpiece. Capacitors will be charged automatically. Treatment can begin after charging
accomplished. Press Standby to turn off the handpiece.
Treatment modeTo indicate the current treatment mode.
Treatment parametertreatment parameters recorded in treatment mode.
State indicationTo indicate the current state and the flash numbers of the handpiece.
Treatment record To indicate the current treatment record, different treatment records can be
recorded to facilitate different patients. Treatment records can be altered, three
choices available.
Cooling adjusting: To adjust the cooling temperature of the handpiece, five levels available. The
more blue snowflakes are, the cooler it will get. When the blue snowflakes
disappear, cooling stops.
Return button: To return to the menu of Select Therapy Program not available when it is gray
(during treatment).
IPL energy:

To adjust the output energy of the handpiece. Energy value will be displayed on the
screen while adjusting, adjustable range: 1~50J/cm2. This setting can be done
directly during treatment with or . to increase, to decrease
press and hold or to rapidly adjust the output energy.

RF energy: To adjust the RF output energy, Energy value will be displayed on the screen while
adjusting, adjustable range: 1~20. This setting can be done directly during
treatment with or . to increase, to decreasepress or
to rapidly adjust the output energy.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
11

The functions of IPL and RF can be turned on or off separately, but make sure that at least one of
them is turned on. Pressing Ready cannot light the lamp when IPL function is off work.

Status Prompted Window

treatment parameter
Adjust treatment parameter ,we can change the output energy of the treatment head, pulse duration,
pulse number,thus can get different treatment effect. There are 8 items adjustable.

RadioFrequency50~2500msUnit:50msThe greater the datathe


longer the time of RF. 600ms is recommended

Pulse number(1-6), 3 is recommend

Pulse charge interval time(1-4s) 2S is recommended


Press '' or '' to increase or decrease parameters
First pulse duration:To adjust width of first pulse.The range is 1-10ms. 0.1ms as every unit.
First pulse delay:To adjust delay between first pulse and next pulse.The range is 1-100ms,each
unit is 1ms.
Second pulse duration:To adjust width of first pulse.The range is 1-10ms. 0.1ms as every unit.
Second pulse delay:To adjust delay between second pulse and next pulse.The range is 1100ms,each unit is 1ms.
Repeat pulse duration:To adjust duration of third pulse and repeat pulse.The range is 110ms,every unit is 0.1ms.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
12

Pulse output
First

Second

First Delay

Repeat

First

Second
RF delay

Discharge
interval

Treatment
Pressing "Ready" button (green) to start treatment head and charge capacitors automatically, Start
the treatment after the capacitors finish charging. Press "Standby" button (red) to light up the
treatment head, system goes into standby mode. After finishing charging, please wait 10 seconds to
start treatment after cooling the treatment head. After pressing "ready" button, any buttons on the
screen no response.After releasing the "ready" button,other button can be adjusted At the end of
treatment, pressing"standby" button exit the treatment program and close the treatment
head.
Doing the treatment with RF should make the skin good contact with electrode and daubs cold gel.
The energy should adjust from low to high and the time can not keep too long when the skin
contacts with electrode to avoid scalding. The feeling of RF treatment is hot inner of the skin. If the
tingle is strong, the reason could be that the cold gel is not enough and the skin is not good
contacting with electrode. The way to solve the problem is to daubs cold gel again or adjust
electrode.

RF treatment

RF
Pulse

Cooling

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
13

LASER treatment

frequency

engery

Chapter 6 Treatment

6.1 Principle
E Light(IPL and RF)combines three advanced technologies: Bipolar Radio Frequency +

IPL

+Skin Contact Cooling.When the three are united in one treatment, wonderful treatment
experience and result can beexpected. The energy of Radio Frequency can reach the middle
and deep layer of the skin and heat up tissue, thus, lower energy is applied during the IPL
treatment. Uncomfortable feeling during the IPL treatment will be decreased significantly and
better result can be expected. In addition, cooling system involved in E-light can also ease the
uncomfortable feeling.The absorbing of the energy of radio frequency is not concerned with
melanin. So, the E-Lighttreatment can get good result on the soft or thin hair so as to decrease
the risk caused by traditional IPL treatment.

6.2 Hand-piece and Application


Wavelength

Treatment

430-1200nm

Acne removal

530-1200nm

Freckles removal, Skin rejuvenation

560-1200nm

Whitening skin, Skin rejuvenation

580-1200nm

Vascular removal, fade melasma, skin rejuvenation

640-1200nm

Thick Hair removal

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
14

The darker the skin

1.
2.

Decrease the fluence


Increase the pulse delay (allow more cooling)

The lighter the skin

1. Increase the fluence


2. Decrease the pulse delay

The darker the hair / pigmented lesion

1.
2.

The lighter the hair / pigmented lesion

1. Increase the fluence


2. Decrease the pulse delay

Fine blood vessels

1. higher fluence
2. Decrease the pulse delay
3. Decrease the pulse width

Thicker blood vessels

1. Increase pulse delay (allow more cooling)


2. Increase the pulse width

The smaller the target size / lesion

1.

Decrease pulse delay

The larger the target size / lesion

1.

Increase pulse delay

Bony prominences (forehead, malar area,


shins)

1.

Decrease the fluence by 10-20%

Decrease the fluence


Increase the pulse delay (allow more cooling)

(allow more cooling)

6.3 Attentions before the treatment


1. Consultation
patients who have the following conditions but not limited should not take the treatment :
A. Pregnant lady;
B. Hypersusceptible to light or recently take medicines, such asacheomycin;
C. Skin easy to scar;
D. Diabetes (blisters maybe appear and not easy to heal up);
E. Insolation in sunlight in recent 2 weeks;
F. Heart disease;
G. Epilepsy, and contagious skin disease, such as herpes;
H. Skin cancer.
2. Preparation
When begin the treatment, take off the accessories such as watch, rings, bracelets or
other metallic things which might be reflect light and cause danger during the treatment.
Wipe off the cosmetic and clean the skin. Ware the goggles to protect the eyes of the
patients and the beautician.
3. Sanitize the treatment head with alcoholized cotton balls.
4. Clean the filters with alcoholized cotton balls.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
15

6.4 Hair removal


1. Cut or shave hair to 1-2mm or ask patients to shave at home 2-3 days before treatment.
2. Clear treatment area.
3. Turn on machine ,put the 640nm or 690nm filter into the slot, select "hair removal",adjust
the parameter, set it to ready .
4. Put cooling gel on treatment area about 2mm.
5. Wear protect goggles for patient and operator.
6. Shot the treatment area, let the crystal tip to touch cooling gel, You are permitted to have
1/3 overlapping on treatment area.
7. Wipe off cooling gel after treatment and clear treatment area with cooling water. Ifpatients
feelwarm or hot, you may put ice bag on treatment area until heat disappear.
8. Treatment Parameter:

Woman:
Skin Type

Pulses
number

First
pulse

First
delay

Second
pulse

Second
delay

Fluency
(640nm filter)

One

6.0

21

6.5

22

33

Fluency
(690nm
filter)
34

Two

6.0

21

6.5

22

31

32

Three

5.0

22

5.5

23

29

30

Four

4.5

23

5.0

24

27

28

Five

4.5

24

5.0

24

26

27

Skin Type

Pulses
number

First
pulse

First
delay

Second
pulse

Second
delay

Fluency
(640nm filter)

Fluency
(690nm filter)

One

5.5

20

6.0

21

32

33

Two

5.5

20

6.0

21

30

31

Three

5.0

21

5.5

22

28

29

Four

4.5

22

5.0

23

26

27

Five

4.5

23

5.0

24

25

26

Man:

** If application for removal of facial and upper lip area, the fluency should be reduced by 2
to 3 Joules
** If application for fine and thin hair, the fluency can be increased by 1 to 2 Joules,D1
reduce by 1 to 2.
** If application for coarse and thick hair, the fluency can be reduced by 2 to 3 Joules ,D1
increase by 1 to 2.
** If using spot size 15x50mm,the fluency should be increased by 2 to 3 Joules.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
16

6.5 Skin rejuvenation


1. Clear treatment area.
2. Turn on machine ,put the 560nm filter into the slot, select "skin rejuvenation",adjust the
parameter, set it to ready .
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. Ifpatients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
7.Treatment parameter:
Skin Type
Pulses
number

First
pulse

First
delay

Second
pulse

Second
delay

Fluency (560nm
filter)

One

5.0

20

5.5

21

24

Two

5.0

20

5.5

21

23

Three

4.5

21

5.0

22

22

Four

4.0

22

4.5

23

21

Five

4.0

23

4.5

24

19

**If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules.

6.6 Pigmentation Therapy


1. Clear treatment area.
2. Turn on machine ,put the 480nm or 530nm filter into the slot, select "pigmentation
therapy",adjust the parameter, set it to ready.
3. Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
6. Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
Disappears.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
17

7.Treatment parameter:
Skin Type
Pulses
First
numbe pulse
r
One
3
5.0

First
delay

Second
pulse

Pulses
number

Fluency
(480nm filter)

Fluency
(530nm filter)

20

5.5

21

28

29

Two

5.0

20

5.5

21

27

28

Three

4.5

21

5.0

22

26

27

Four

4.0

22

4.5

23

25

26

Five

4.0

23

4.5

24

24

25

**If spot size 15x50mm, the fluency should be increased by 2 to 3 Joules.

6.7 Vascular Therapy


1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "vascular therapy",adjust the
parameter, set it to ready .
Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
7.Treatment parameter:
Skin Type
Pulses
number
One
Two
Three
Four
Five

3
3
4
4
5

First
pulse

First
delay

5.0
5.0
4.5
4.0
4.0

20
20
21
22
23

Secon
d
pulse
5.5
5.5
5.0
4.5
4.5

Pulses
numbe
r
21
21
22
23
24

Fluency (580nm
filter)
25
24
23
22
20

** If application for thin veins beneath the skin, the fluency can be reduced by
1 to 2 Joules
** If application for thick veins beneath the skin, the fluency can be increased
by 1 to 2 Joules
** If using spot size 15x50mm, the fluency should be increased by 2 to 3
Joules.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
18

6.8 Acne Therapy


1. Clear treatment area.
2. Turn on machine ,put the 430nm filter into the slot, select "acne therapy",adjust the
parameter, set it to ready .
Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
disappears.
7.Treatment parameter:
Skin Type
Pulses
number

First
pulse

First
delay

One

5.0

20

Secon
d
pulse
5.5

Pulses
numbe
r
21

Fluency(430nm
filter)

Two

5.0

20

5.5

21

24

Three

4.5

21

5.0

22

23

Four

4.0

22

4.5

23

22

Five

4.0

23

4.5

24

20

25

**If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules.

6.9 Wrinkle removal


1. Clear treatment area.
2. Turn on machine ,put the 580nm filter into the slot, select "wrinkle removal",adjust the
parameter, set it to ready .
Put cooling gel on treatment area about 2mm, you are suggested to put cooling gel in
refrigerator to keep temperature of gel during 0-4.
4. Wear goggles for patient and operator
5. Shot the treatment area, let the crystal tip to touch cooling gel. You are permitted to have
1/3 overlapping on treatment area.
Wipe off cooling gel after treatment and clear treatment area with cooling water. If patients
feel warm or hot, you may put ice bag on treatment area for 30 minutes until heat-feeling
Disappears.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
19

7.Treatment parameter:
Skin Type
Pulses
number

First
pulse

First
delay

Second
pulse

Second
delay

Fluency (560nm
filter)

One

5.0

20

5.5

21

24

Two

5.0

20

5.5

21

23

Three

4.5

21

5.0

22

22

Four

4.0

22

4.5

23

21

Five

4.0

23

4.5

24

19

**If using spot size 15x50mm, the fluency should be increased by 2 to 3 Joules.

6.10 After Treatment care


Untoward Reactions:Pain, Scab formation, Pigmentation change, Scar formation, Swelling
and Erythema.
2. Protect treated skin from exposure to the sunlight or irradiation of ultraviolet radiation.
3. DO NOT use irritative cosmetics within 24 hours.
4. Wash face with clean water, use moisture cosmetic when necessary.
5. Dont eat piquant food.
6. Take Vc or VE

Chapter 7 Service manual

No power

Check power cable


Check circuit breaker / fuse
Check key switch
Disengage the emergency cut off switch by rotating towards
the direction of the arrows indicated
Notify your distributor

Key pads are none responsive


System failed to initialize
Malfunction of flash lamp on
the treatment head

The treatment head is leaking

The treatment handle is warm

The power of The treatment


head has weakened

Please contact the dealer.


Not enough power, please check main power supply.
Please contact the dealer.
The treatment head / flash lamp has reached its maximum
life span (100,000) shots. Replace the treatment head
The E-light treatment head is probably damaged, please
change the treatment head or contact the dealer.
The treatment head is probably damaged, please change the
treatment head or contact the dealer.
The system is designed for continued used for up four hours
in optimal environmental temperature and humidity.
Always place the system on standby mode while awaiting
treatment. The system might have been left on for an extended
period. Turn the unit off, let it cool down for half an hour then restart
Contact the dealer.
The treatment head has nearly reached its maximum life
span (100,000 shots) the fluence can be adjusted by a few joules
to compensate.

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
20

Chapter 8 Maintenance
1. Please change the distilled or pure water every 2-3 month to keep the water tank clean
and make sure water circulation well.
2. Please get water out from the unit before moving it for long distance, e.g. from one city to
another.
3. Clean the main host.
4.Clear Sapphire Crystal right after each treatment.
5. Clear filter right after each treatment, and put into the box.
6 Replace the treatment hand-piece at a appropriate time(maximum life 100000 shots).

Sources of datahttp://www.bomeitong.com/BM11S-E-light-IPL/RF-laser-PDT-machine_206.html
E-light IPL beauty machine
21

Você também pode gostar