Você está na página 1de 4

Eccentric Diaphragm Pumps for Gas / Air

SP 620 / 625 / 628 EC-DU

SP 620 EC-DU

SP 628 EC-DU

SP 625 EC-LC-DU

Product Features

Applications

delivers two different media at the same time


oil free
maintenance free
minimum vibrations
reduced pulsation
low noise
small size
high flow
lightweight
minimal current consumption
virtually leak tight

Blood Pressure Monitoring


Anaesthesia Equipment
Exhaust Gas Analysers
Gas Detectors
Autosamplers
Pipetting Devices
Pneumatics

Am Lichtbogen 7 45141 Essen Germany


Phone: +49 201 31697-0 Fax: +49 201 31697-29
e-mail: info@schwarzer.com http://www.schwarzer.com

Subject to change without notice. Given values are for preliminary information only and not legally binding. 04.11.2015

Eccentric Diaphragm Pumps for Gas / Air

SP 620 / 625 / 628 EC-DU


The pumps listed below represent a typical selection of our wide range of eccentric pumps and are intended for initial tests.
Customised versions for your individual application would be made without extra costs - please contact us!

Note: In order to achieve highest life time, we offer different diaphragm designs. Please inform us about your application.
Designation

SP 620 EC-DU-DV SP 620 EC-DU-VD

Operating Voltage
Art.No. (parallel)
Art.No. (serial)

12 Vdc
7s57082

24 Vdc
7s57083

12 Vdc
7s57131

SP 625 EC-LC-DU-DV

24 Vdc
7s57132

6 Vdc
7s57077

12 Vdc
7s57078

SP 625 EC-LC-DU-VD

24 Vdc
7s57079

6 Vdc
7s57095
7s57147

12 Vdc
7s57096
7s57148

24 Vdc
7s57097
7s57149

Pneumatic Performance
parallel
Free Flow [l/min]

parallel

8,5

6,5

8,5

6,5

5,2
1870

4,0
1800

3,4
-660

2,5
-640

3,6
-710

2,5
-700

parallel
13,0

serial / parallel
8,0 / 13,0

9,7
1880

6,0
-660

4,2 / 6,0
-910 / -765

Pressure Side

flow at:
300 mbar [l/min]
max. Pressure [mbar]
flow at:

Vacuum Side

-300 mbar [l/min]


max. Vacuum [mbar]

Motor / Power Consumption


Motor Type
Iron core with ball bearings
-

standard
optional
max. Current [mA]

800

350

800

Low cost iron core with ball bearings


350

2000

1100

800

2000

1100

800

Construction
Pump Head
standard
optional

PPS
customer specific - upon request

Diaphragm, Valves
standard
optional
Tubing

EPDM
FKM, FFKM, PTFE
PUR
230

Weight [g]

250

Performance Curves
l/min

SP 625 EC-LC-DU-DV 6 / 12 / 24 Vdc parallel


SP 625 EC-LC-DU-VD 6 / 12 / 24 Vdc parallel
SP 625 EC-LC-DU-VD 6 / 12 / 24 Vdc serial
SP 620 EC-DU-DV 12 Vdc parallel
SP 620 EC-DU-VD 12 Vdc parallel
SP 620 EC-DU-DV 24 Vdc parallel
SP 620 EC-DU-VD 24 Vdc parallel

12,0

10,0

8,0

6,0

4,0

2,0

0,0
-1000

-800

-600

-400

-200

200

400

600

800

1000

1200

1400

1600

1800mbar

Am Lichtbogen 7 45141 Essen Germany


Phone: +49 201 31697-0 Fax: +49 201 31697-29
e-mail: info@schwarzer.com http://www.schwarzer.com

Subject to change without notice. Given values are for preliminary information only and not legally binding. 04.11.2015

Eccentric Diaphragm Pumps for Gas / Air

SP 620 / 625 / 628 EC-DU


The pumps listed below represent a typical selection of our wide range of eccentric pumps and are intended for initial tests.
Customised versions for your individual application would be made without extra costs - please contact us!

Note: In order to achieve highest life time, we offer different diaphragm designs. Please inform us about your application.
Designation

SP 628 EC-DU-DV

Operating Voltage
Art.No. (parallel)
Art.No. (serial)

12 Vdc
7s57134

SP 628 EC-DU-VD

24 Vdc
7s57135

12 Vdc
7s57137
7s57145

24 Vdc
7s57138
7s57146

Pneumatic Performance
Free Flow [l/min]

parallel
7,8

serial / parallel
5,8 / 7,8

6,0
1880

4,0
-700

2,7 / 4,3
-920 / -730

flow at:
300 mbar [l/min]
max. Pressure [mbar]
flow at:
-300 mbar [l/min]
max. Vacuum [mbar]

Motor / Power Consumption


Motor Type
Iron core with ball bearings
-

standard
optional
max. Current [mA]

780

340

780

340

Construction
Pump Head
PPS
customer specific - upon request

standard
optional
Diaphragm, Valves
standard
optional
Tubing

EPDM
FKM, FFKM, PTFE
PUR
320

Weight [g]

320

Performance Curves
l/min
SP 628 EC-DU-DV 12 / 24 Vdc parallel
SP 628 EC-DU-VD 12 / 24 Vdc parallel

8,0

SP 628 EC-DU-VD 12 / 24 Vdc serial


6,0

4,0

2,0

0,0
-1000

-800

-600

-400

-200

200

400

600

800

1000

1200

1400

1600

1800mbar

Am Lichtbogen 7 45141 Essen Germany


Phone: +49 201 31697-0 Fax: +49 201 31697-29
e-mail: info@schwarzer.com http://www.schwarzer.com

Subject to change without notice. Given values are for preliminary information only and not legally binding. 04.11.2015

Eccentric Diaphragm Pumps for Gas / Air

SP 620 / 625 / 628 EC-DU

SP 620 EC-DU

SP 625 EC-LC-DU

SP 628 EC-DU

Standard: connection ports as shown.