Brochure | ABB solar inverters 3
Power plants
In large multi-megawatt photovoltaic (PV) power plants the PV
modules are typically mounted at ground level, either on fixedtilted structures facing the sun or on tracking devices. For these
land-based power plants ABB central inverters offer the most
cost-effective solution for PV energy generation by feeding
electricity directly to the medium voltage (MV) power distribution
network (i.e. grid). ABBs offering for large plants includes a
wide range of central inverters, inverter stations and megawatt
stations.
10
100
3000
Brochure | ABB solar inverters 5
String inverters
Efficiency of up to 96.3%
Despite the isolated operation, the UNO-2.0-I and UNO-2.5-I
feature an efficiency of 96.3%. The wide input voltage range
makes the inverter suitable to low power installations with
reduced string size.
In addition to its new look, this inverter has new features
including a special built-in heat sink compartment and front
panel display system.
This rugged outdoor inverter has been designed as
a completely sealed unit to withstand the harshest
environmental conditions.
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Single-phase output
High frequency isolated topology
Each inverter is set on specific grid codes which can be
selected in the field
Wide input voltage range
Flat efficiency curves ensure high efficiency at all output
levels ensuring consistent and stable performance across
the entire input voltage and output power range
98
98
96
96
94
94
92
92
90
90
Efficiency [%]
Efficiency [%]
88
86
88
86
84
84
Vin=200V
82
Vin=200V
82
Vin=360V
Vin=360V
80
80
Vin=425V
78
0%
Vin=425V
78
10%
20%
30%
40%
50%
60%
70%
80%
90%
0%
100%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
UNO-2.0-I-OUTD
UNO-2.5-I-OUTD
520 V
360 V
2100 W
2600 W
1
2300 W Linear derating from max to null
[470 VVMPPT520 V]
200...470 V
12.5 A / 12.5 A
12.8 A / 12.8 A
15.0 A
DC connection type
Input protection
Reverse polarity protection
Yes
16 A / 600 V
Output side
AC grid connection type
Rated AC power (Pacr @cos=1 )
Maximum AC output power (Pacmax @cos=1)
Single-phase
2000 W
2200 W
230 V
AC voltage range
Maximum AC output current (Iac,max)
Contributory fault current
Rated output frequency (fr)
Output frequency range (f min...fmax)
Nominal power factor and adjustable range
Total current harmonic distortion
AC connection type
2500 W
2750 W
4)
180...264 V
1)
10.5 A
12.5 A
16.0 A
50 Hz / 60 Hz
47...53 Hz / 5763 Hz
> 0.990
2)
8)
< 2%
Screw terminal block, cable gland M25
Output protection
Anti-islanding protection
Maximum external AC overcurrent protection
Output overvoltage protection - varistor
5)
IN1.1(+)
IN1.2(+)
IN1.1(+)
+
IN1.2(+)
IN
IN
IN1.1(-)
IN1.2(-)
IN1.1(-)
IN1.2(-)
MPPT
(DC/DC)
HF
transformer
Bulk caps
Inverter
(DC/AC)
Grid parallel
relay
Line
filter
-L
IN
-N
- PE
Standard version
-S version
RS485
+ T/R
- T/R
RTN
DC/AC
DSP
Contr.
DC/DC
DSP
Contr.
Remote control
+R
-R
Alarm
N.C
N.O
C
Control circuit
UNO-2.0-I-OUTD
UNO-2.5-I-OUTD
Operating performance
Maximum efficiency (max)
Weighted efficiency (EURO/CEC)
96.3%
95.1% / -
95.4% / -
24.0 W
Night consumption
< 0.6 W
3)
Communication
Wired local monitoring
Remote monitoring
PVI-USB-RS232_485 (opt.)
VSN300 Wifi Logger Card (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
User interface
Graphic display
Environmental
Ambient temperature range
Relative humidity
50 dBA @ 1 m
2000 m / 6560 ft
Physical
Environmental protection rating
IP 65
Cooling
Dimension (H x W x D)
Natural
518 mm x 367 mm x 161 mm / 20.4 x 14.4 x 6.3
Weight
Mounting system
Wall bracket
Safety
Isolation level
Marking
Safety and EMC standard
Grid standard (check your sales channel for availability)
HF transformer
CE (50 Hz only), RCM
EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, AS/NZS 60950.1,
EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3
CEI 0-216), DIN V VDE V 0126-1-1, VDE-AR-N 41057), G83/2, EN 50438 (not for all national
appendices), RD 1699, RD 413, AS 4777.2, AS 4777.3, C10/11, IEC 61727, IEC 62116
UNO-2.0-I-OUTD
UNO-2.5-I-OUTD
UNO-2.0-I-OUTD-S
UNO-2.5-I-OUTD-S
5)
The AC voltage range may vary depending on specific country grid standard
Limited to 2500 W for Germany
6)
The Frequency range may vary depending on specific country grid standard
Limited to plant power 3 kW
3)
7)
Stand-by consumption < 8.0 W
Limited to plant power 3.68 kVA
4)
8)
Limited to 2000 W for Germany
The unit has not reactive power capability
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
2)
Efficiency of up to 96.8%
The transformerless (TL) operation gives the highest efficiency of
up to 96.8%. The wide input voltage range makes the inverter
suitable for low power installations with reduced string size.
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Single-phase output
Transformerless topology
Each inverter is set on specific grid codes which can be
selected in the field
Wide input voltage range
High speed and precise MPPT algorithm for real time
power tracking and improved energy harvesting
Dual input section with independent MPP tracking, allows
optimal energy harvesting from two sub-arrays oriented in
different directions
99
99
98
98
97
97
96
96
95
95
94
94
93
93
Efficiency [%]
Efficiency [%]
92
91
90
92
91
90
89
89
88
200Vdc
88
215Vdc
87
360Vdc
87
360Vdc
86
480Vdc
86
480Vdc
85
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
85
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
PVI-3.0-TL-OUTD
PVI-3.6-TL-OUTD
PVI-4.2-TL-OUTD
2000 W
600 V
200 V (adj. 120...350 V)
0.7 x V start...580 V (min 90 V)
360 V
3750 W
2
3000 W
3000 W
160...530 V
120...530 V
140...530 V
3120 W
4375 W
3000 W
3300 W 4)
3330 VA
14.5 A
16.0 A
20.0 A
Single-phase
3600 W
4000 W 5)
4000 VA
230 V
180...264 V 1)
17.2 A 2)
19.0 A
50 Hz / 60 Hz
47...53 Hz / 5763 Hz 3)
> 0.995, adj. 0.9 with
Pacr =3.6 kW
< 3.5%
Screw terminal block, cable gland M25
According to local standard
25.0 A
2 (L - N / L - PE)
4200 W
4600 W 6)
4670 VA
20.0 A
22.0 A
25.0 A
IN1.1(+)
IN1.2(+)*
IN1
IN1
IN1.1(-)
IN1.2(-)*
IN1.1(-)
MPPT 1
(DC/DC)
Bulk caps
Inverter
(DC/AC)
IN1
Line
filter
Grid parallel
relay
L
IN1.2(-)*
IN2.1(+)
IN2.1(+)
IN2
IN2
IN2.1(-)
IN2.1(-)
MPPT 2
(DC/DC)
PE
Residual current
detection
IN2
-
RS485
Standard version
+ T/R
-S version
- T/R
RTN
DC/DC
DSP
contr.
DC/AC
DSP
contr.
Remote Control
+R
-R
Alarm
N.C
N.O
C
Control circuit
PVI-3.0-TL-OUTD
PVI-3.6-TL-OUTD
PVI-4.2-TL-OUTD
96.8%
96.0% / 10.0 W
< 0.4 W
PVI-USB-RS232_485 (opt.)
VSN300 Wifi Logger Card (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
VSN300 Wifi Logger Card (opt.)
16 characters x 2 lines LCD display
-25...+60C /-13...140F with
derating above 50C/122F
IP 65
Natural
618 mm x 325 mm x 222 mm / 24.3 x 12.8 x 8.7
17.5 kg / 38.5 lbs
Wall bracket
Transformerless
CE (50 Hz only), RCM
EN 50178, IEC/EN 62109-1,
EN 50178, IEC/EN 62109-1,
IEC/EN 62109-2, AS/NZS 3100, IEC/EN 62109-2, AS/NZS 3100,
EN 61000-6-1, EN 61000-6-3,
EN 61000-6-1, EN 61000-6-3,
EN 61000-3-2, EN 61000-3-3 EN 61000-3-11, EN 61000-3-12
CEI 0-21, DIN V VDE V 0126-1-1, CEI 0-21, DIN V VDE V 0126-1-1,
VDE-AR-N 4105, G83/2, G59/3,
VDE-AR-N 4105, G83/2, G59/3,
EN 50438 (not for all national
EN 50438 (not for all national
appendices), RD 1699, RD 413,
appendices), RD 1699, RD 413,
ITC-BT-40, AS 4777.2, AS 4777.3, ITC-BT-40, AS 4777.2, AS 4777.3,
IEC 61727, IEC 62116
IEC 61727, IEC 62116
PVI-3.0-TL-OUTD
PVI-3.0-TL-OUTD-S
The AC voltage range may vary depending on specific country grid standard
For UK G83/2 setting, maximum output current limited to 16A up to a maximum output power of 3.68 kW
3)
The Frequency range may vary depending on specific country grid standard
Remark. Features not specifically listed in the present data sheet are not included in the product
PVI-3.6-TL-OUTD
PVI-3.6-TL-OUTD-S
1)
4)
2)
5)
6)
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Single-phase output
Transformerless topology
Each inverter is set on specific grid codes which can be
selected in the field
Dual input section with independent MPP tracking, allows
optimal energy harvesting from two sub-arrays oriented in
different directions
100
100
99
99
98
98
97
97
96
96
Efficiency [%]
Efficiency [%]
95
94
93
94
93
250 Vdc
92
10%
20%
30%
40%
50%
60%
70%
80%
90%
360 Vdc
91
480 Vdc
0%
250 Vdc
92
360 Vdc
91
90
95
100%
90
480 Vdc
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
PVI-5000-TL-OUTD
PVI-6000-TL-OUTD
600 V
200 V (adj. 120...350 V)
0.7 x Vstart...580 V (min 90 V)
360 V
5150 W
6200 W
2
4000 W
150...530 V
180...530 V
6000 W
6000 W
6670 VA
230 V
180...264 V
25.0 A
32.0 A
1)
30.0 A
40.0 A
50 Hz / 60 Hz
47...53 Hz / 5763 Hz 2)
> 0.995, adj. 0.9 with P acr =5.0 kW
> 0.995, adj. 0.9 with Pacr =6.0 kW
< 3.5%
Terminal block, cable gland M32
IN1.1(+)
IN1.2(+)
IN1
IN1
IN1.1(-)
IN1.2(-)
IN1.1(-)
MPPT 1
(DC/DC)
Inverter
(DC/AC)
Bulk caps
IN1
Line
filter
Grid parallel
relay
L
IN1.2(-)
IN2.1(+)
IN2.2(+)
IN2.1(+)
IN2.2(+)
IN2
IN2
IN2.1(-)
IN2.2(-)
IN2.1(-)
MPPT 2
(DC/DC)
PE
Residual current
detection
IN2
-
IN2.2(-)
RS485
Standard version
+ T/R
-S version
- T/R
RTN
DC/DC
DSP
contr.
DC/AC
DSP
contr.
Remote control
+R
-R
Alarm
N.C
N.O
C
Control circuit
PVI-5000-TL-OUTD
PVI-6000-TL-OUTD
According to local standard
32.0 A
40.0 A
2 (L - N / L - PE)
97.0%
96.4% / 10.0 W
< 0.4 W
PVI-USB-RS232_485 (opt.)
VSN300 WIFI Logger Card (opt.),
PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
VSN300 Wifi Logger Card (opt.)
16 characters x 2 lines LCD display
-25...+60C (-13...+ 140F)
IP 65
Natural
810 mm x 325 mm x 222 mm / 31.9 x 12.8 x 8.7
< 26.0 kg / 57.3 lbs
Wall bracket
Transformerless
CE (50 Hz only), RCM
EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, EN 61000-6-1,
EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
CEI 0-21, DIN V VDE V 0126-1-1, G59/3, EN 50438 (not for all national appendices),
RD 1699, RD 413, ITC-BT-40, AS 4777.2, AS 4777.3, C10/11, IEC 61727, IEC 62116
PVI-5000-TL-OUTD
PVI-5000-TL-OUTD-S
PVI-6000-TL-OUTD
PVI-6000-TL-OUTD-S
3)
The AC voltage range may vary depending on specific country grid standard
4600 W for Australia
The Frequency range may vary depending on specific country grid standard
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
2)
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Three-phase bridge topology for DC/AC output converter
Transformerless topology
Two independent MPPT channels for TRIO-7.5/8.5 allows
optimal energy harvesting from two sub-arrays oriented in
different directions (one MPPT channel for TRIO-5.8)
Flat efficiency curves ensure high efficiency at all output
levels ensuring consistent and stable performance across
the entire input voltage and output power range
Wide input voltage range
Remote inverter upgrade
Reactive power management
100
100
99
99
98
98
97
97
96
96
Efficiency [%]
Efficiency [%]
95
94
95
94
93
93
320 Vdc
92
320 Vdc
92
620 Vdc
91
620 Vdc
91
800 Vdc
800 Vdc
90
90
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
0%
100%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
TRIO-5.8-TL-OUTD
5950 W
1
6050 W
Linear derating from max to null
[800 VVMPPT950 V]
320800 V
-
TRIO-7.5-TL-OUTD
TRIO-8.5-TL-OUTD
1000 V
350 V (adj. 200...500 V)
0.7 x Vstart950 V (min 200 V)
620 V
7650 W
2
8700 W
2
4800 W
4800 W
320800 V
320800 V
5800 W
5800 VA
10.0 A
12.0 A
8500 W
8500 VA
14.5 A
16.5 A
16.0 A
20.0 A
97.4% / 32 W
98.0%
97.5% / 36 W
<3W
97.5% / 36 W
IN1.2(+)
IN1
IN1
IN1.1(-)
IN1.1(-)
MPPT 1
(DC/DC)
Bulk caps
Inverter
(DC/AC)
IN1
Line
filter
Grid parallel
relay
L1
IN1.2(-)
L2
L3
MPPT 2
(DC/DC)
*IN2.1(+)
*IN2.1(+)
N
PE
*IN2
IN2
IN2
*IN2.1(-)
*IN2.2(+)
*IN2.1(-)
*IN2.2(-)
Standard version
-S version
Control circuit
DC/AC
DSP
contr.
DC/DC
DSP
contr.
Ethernet
board
(opt.)
RJ_45
+ T/R
- T/R
GND
K1
K2
K3
K4
I1
I2
GND
AN1
AN1 COM
AN2
AN2 COM
24V
GND
PT1
PT2
PT3
MODBUS/PMU RS485
Service pc_RS485
+ T/R
- T/R
GND
Remote control 1
+R
GND
Analog input
Remote control 2
Service
board
(opt.)
Analog input
+R
GND
Alarm
24 V - 100 mA
N.C
N.O
C
Supervisor
board
TRIO-5.8-TL-OUTD
TRIO-7.5-TL-OUTD
TRIO-8.5-TL-OUTD
TRIO-7.5-TL-OUTD-400
TRIO-7.5-TL-OUTD-S-400
TRIO-8.5-TL-OUTD-400
TRIO-8.5-TL-OUTD-S-400
3)
The AC voltage range may vary depending on specific country grid standard
Check availability before to order
The Frequency range may vary depending on specific country grid standard
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
2)
Designed for commercial usage, this PVI-10/12.5, threephase inverter is highly unique in its ability to control the
performance of the PV panels, especially during periods
of variable weather conditions.
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
True three-phase bridge topology for DC/AC output
converter
Transformerless topology
Each inverter is set on specific grid codes which can be
selected in the field
Wide input voltage range
Dual input section with independent MPPT allows optimal
energy harvesting from two sub-arrays oriented in different
directions
99
99
98
98
97
97
96
96
Efficiency [%]
Efficiency [%]
95
94
95
94
93
93
300 Vdc
92
360 Vdc
92
580 Vdc
580 Vdc
91
90
91
750 Vdc
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
90
750 Vdc
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
PVI-10.0-TL-OUTD
PVI-12.5-TL-OUTD
900 V
360 V (adj. 250...500 V)
0.7 x V start850 V (min 200 V)
580 V
10300 W
12800 W
2
6500 W
8000 W
300...750 V
360...750 V
12500 W
13800 W 4)
13800 VA
400 V
320...480 V
1)
16.6 A
19.0 A
20.0 A
22.0 A
50 Hz / 60 Hz
47...53 Hz / 5763 Hz 2)
> 0.995, adj. 0.9 with Pacr =10.0 kW,
> 0.995, adj. 0.9 with Pacr =12.5 kW,
0.8 with max 11.5 kVA
0.8 with max 13.8 kVA
< 2%
Screw terminal block, cable gland M40
According to local standard
25.0 A
3 plus gas arrester
97.8%
97.1% / -
97.2% / 30.0 W
< 1.0 W
100%
IN1.1(+)
+
IN1.2(+)
IN1
IN1
IN1.1(-)
IN1.2(-)
IN1.1(-)
MPPT 1
(DC/DC)
Bulk caps
Inverter
(DC/AC)
IN1
Line
filter
Grid parallel
relay
L1
IN1.2(-)
L2
IN1.3(-)
L3
N
IN2.1(+)
IN2.2(+)
IN2.3(+)
IN2.1(+)
+
IN2
IN2
IN2.1(-)
IN2.2(-)
IN2.2(+)
IN2.1(-)
MPPT 2
(DC/DC)
PE
IN2
-
IN2.2(-)
IN2.3(-)
Standard version
-S version
IN1.1(+)
IN1.2(+)
IN1.3(+)
IN1
IN1.1(-)
RS485
IN1.2(-)
+ T/R
- T/R
IN1.3(-)
RTN
IN2.1(+)
DC/AC
DSP
contr.
DC/DC
DSP
contr.
IN2.2(+)
Remote control
+R
IN2.3(+)
-R
IN2
Alarm
N.C
IN2.1(-)
N.O
IN2.2(-)
Control circuit
IN2.3(-)
-FS version
PVI-10.0-TL-OUTD
PVI-12.5-TL-OUTD
PVI-USB-RS232_485 (opt.)
VSN300 Wifi Logger Card (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
VSN300 Wifi Logger Card (opt.)
16 characters x 2 lines LCD display
-25...+60C (-13...+140F)
-25...+60C (-13...140F)
with derating above 55C (131F)
with derating above 50C (122F)
0...100% condensing
50 dBA @ 1 m
2000 m / 6560 ft
IP 65
Natural
716 mm x 645 mm x 224 mm / 28.2 x 25.4 x 8.8
< 41.0 kg / 90.4 lbs
Wall bracket
Transformerless
CE (50 Hz only), RCM
EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, AS/NZS 60950.1,
EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, C10/11,
EN 50438 (not for all national appendices), RD 1699, RD 413, RD 661, P.O. 12.3,
AS/NZS 4777.2, AS/NZS 4777.3, IEC 61727, IEC 62116, BDEW, MEA, NRS 097-2-1
PVI-10.0-TL-OUTD
PVI-10.0-TL-OUTD-S
PVI-10.0-TL-OUTD-FS
PVI-12.5-TL-OUTD
PVI-12.5-TL-OUTD-S
PVI-12.5-TL-OUTD-FS
3)
The AC voltage range may vary depending on specific country grid standard
Limited to 10000 W for Belgium and Germany
4)
The Frequency range may vary depending on specific country grid standard
Limited to 12500 W for Germany
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
2)
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
True three-phase bridge topology for DC/AC output
converter
Transformerless topology
Each inverter is set on specific grid codes which can be
selected in the field
Detachable wiring box to allow an easy installation
Wide input voltage range
Electrolyte-free power converter to further increase the
life expectancy and long term reliability
100
100
99
99
98
98
97
97
96
96
Efficiency [%]
Efficiency [%]
95
94
95
94
93
93
500 Vdc
500 Vdc
92
92
620 Vdc
91
620 Vdc
91
800 Vdc
800 Vdc
90
90
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
0%
100%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
TRIO-20.0-TL-OUTD
TRIO-27.6-TL-OUTD
1000 V
430 V (adj. 250...500 V)
0.7 x V start950 V (min 200 V)
620 V
20750 W
28600 W
2
12000 W
16000 W
440...800 V
500...800 V
27600 W
30000 W 4)
30670 VA
400 V
320...480 V
1)
33.0 A
35.0 A
45.0 A
46.0 A
50 Hz / 60 Hz
47...53 Hz / 5763 Hz 2)
> 0.995, adj. 0.9 with Pacr =20.0 kW,
> 0.995, adj. 0.9 with Pacr =27.6 kW,
0.8 with max 22.2 kVA
0.8 with max 30 kVA
< 3%
Screw terminal block, cable gland PG36
According to local standard
50.0 A
63.0 A
4
4 (Type 2)
98.2%
98.0% / 98.0%
40 W
< 0.6 W
IN1A(+)
+
IN1(+)
IN1B(+)
MPPT 1
(DC/DC)
IN1C(+)
Bulk caps
Inverter
(DC/AC)
IN1D(+)
*IN1E(+)
IN1
IN1
IN1A(-)
Line
filter
IN1
IN1B(-)
IN1(-)
IN1C(-)
IN1D(-)
*IN1E(-)
Current
reading
IN2A(+)
+
IN2(+)
OVP
monitoring
IN2B(+)
IN2C(+)
L1
L1
L1, S
L1
L1, S
L2
L2
L2, S
L2
L2, S
L3
L3
L3, S
L3
L3, S
N, S
PE
MPPT 2
(DC/DC)
-S2X version
-S2 version
Grid parallel
relay
N,S
PE
PE
IN2D(+)
*IN2E(+)
IN2
IN2
IN2A(-)
IN2
IN2B(-)
IN2(-)
-S2F version
IN2C(-)
IN2D(-)
*IN2E(-)
Current
reading
-S2 version
OVP
monitoring
DC/DC
DSP
contr.
-S2X version
* not present on TRIO-20.0-TL
Current reading
OVP monitoring
IN1A(+)
IN1(+)
DC/AC
DSP
contr.
L3, S
N, S
PE
P
Control circuit
IN1C(+)
IN1
IN1A(-)
PMU_RS485
+ T/R
IN1B(-)
-
IN1C(-)
PT 100
IN1D(-)
PT 1000
*IN1E(-)
IN2C(+)
Service or normal
+ T/R
- T/R
GND
Remote control
+R
PC
*IN2E(+)
IN2
IN2A(-)
GND
PMU
AN 1
IN2B(-)
-
PC_RS485
ON/OFF EXT
IN2D(+)
IN2
GND
IN2B(+)
IN2C(-)
IN2D(-)
- T/R
Current
reading
IN2A(+)
IN2(-)
L2, S
L3
IN1D(+)
IN1
IN2(+)
L1, S
L2
IN1B(+)
*IN1E(+)
IN1(-)
L1
Alarm
AN 2
N.C
IN mode
N.O
C
*IN2E(-)
Current
reading
Standard version
-S2F version
* not present on TRIO-20.0-TL
INVERTER
WIRING BOX
TRIO-20.0-TL-OUTD
TRIO-27.6-TL-OUTD
PVI-USB-RS232_485 (opt.)
VSN300 Wifi Logger Card (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
VSN300 Wifi Logger Card (opt.)
Graphic display
-25...+60C /-13...140F with derating above 45C/113F
0...100% condensing
50 dBA @ 1 m
2000 m / 6560 ft
IP 65
Natural
1061 mm x 702 mm x 292 mm/ 41.7 x 27.6 x 11.5
< 70.0 kg / 154.3 lbs (Standard version)
< 75.0 kg / 165.4 lbs (Standard version)
Wall bracket
Transformerless
CE (50 Hz only), RCM
EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 3100, AS/NZS 60950.1, EN 61000-6-2,
EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, C10/11,
EN 50438 (not for all national appendices), RD 1699, RD 413, RD 661, P.O. 12.3, AS 4777.2,
AS 4777.3, BDEW, NRS-097-2-1, MEA, IEC 61727, IEC 62116, Ordinul 30/2013
TRIO-20.0-TL-OUTD-400
TRIO-20.0-TL-OUTD-S2-400
TRIO-20.0-TL-OUTD-S2F-400
TRIO-20.0-TL-OUTD-S2X-400
TRIO-27.6-TL-OUTD-400
TRIO-27.6-TL-OUTD-S2-400
TRIO-27.6-TL-OUTD-S2F-400
TRIO-27.6-TL-OUTD-S2X-400
3)
The AC voltage range may vary depending on specific country grid standard
Limited to 20000 W for Germany
4)
The Frequency range may vary depending on specific country grid standard
Limited to 27600 W for Germany
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
2)
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
100
99
98
Efficiency [%]
97
96
95
94
93
580 Vdc
92
850 Vdc
91
90
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
33 kW
PRO-33.0-TL-OUTD
Input side
Absolute maximum DC input voltage (Vmax,abs)
Startup DC input voltage (Vstart)
Operating DC input voltage range (Vdcmin...Vdcmax)
Rated DC input voltage (Vdcr)
Rated DC input power (Pdcr)
Number of independent MPPT
MPPT input DC voltage range (VMPPTmin...VMPPTmax) at Pacr
Maximum DC input current (Idcmax)/for each MPPT (IMPPTmax)
Maximum input short circuit current for each MPPT
1100 V 3)
610 V
580 to 950 V
580 V
33 700 W
1
580 to 850 V
58 A
80 A
Input protection
Reverse polarity protection
Input over voltage protection for each MPPT varistor (-/S) version
Input over voltage protection plug in modular surge arrester (-SX version)
Yes
Type 2
58 A/1000 V, 50 A/1200 V
15 A/1100 V
-S version
-SX version
Standard version
Inverter
(DC/AC)
DC1 (+)
DC2 (+)
Line filter
Grid parallel
relays
DC3 (+)
DC4 (+)
DC+
L1
DC+
L2
DC5 (+)
DC6 (+)
L3
DC7 (+)
DC8 (+)
N
PE
DC1 ()
DC2 ()
DC3 ()
DC
DC4 ()
DC
DC5 ()
DC6 ()
DC7 ()
DC8 ()
Current
reading
OVP
monitoring
Remote
control unit
interface
Monitoring
interface
OVP
monitoring
Extension
module
Extension
module
Control
unit
Status
leds
33 kW
PRO-33.0-TL-OUTD
According to local standard
80 A
5
98.3%
98.0%/98.1%
20 W
<1W
VSN700 Data logger (opt.)
Detachable graphical display
-25 to +60C /-13 to 140F with derating above 45C/113F
0 to 100% condensing
67 dBA @ 1 m
3000 m / 9840 ft
IP 65 (IP54 fans)
Forced
740 x 520 x 300 mm/29.1" x 20.5" x 11.8"
< 66.0 kg/146 lbs (standard version)
Wall bracket
Transformerless
CE, RCM
IEC/EN 62109-1, IEC/EN 62109-2, EN61000-6-2, AS/NZS 3200, EN61000-6-3,
EN61000-3-11, EN61000-3-12
CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, C10/11, EN 50438 (not for all
national appendices), PPC Greece, RD 1699, RD 413, RD 661, P.O. 12.3, UNE206007-1, AS 4777.2,
AS 4777.3, BDEW, NRS-097-2-1, SAGC, MEA, PEA, IEC 61727, IEC 62116, ABNT NBR16149/16150
PRO-33.0-TL-OUTD-400
PRO-33.0-TL-OUTD-S-400
PRO-33.0-TL-OUTD-SX-400
3)
The AC voltage range may vary depending on specific country grid standard
Inverter does not start >1000 V
The frequency range may vary depending on specific country grid standard
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
2)
PV + Storage
ABB PV + Storage
REACT-3.6/4.6-TL
3.6 to 4.6 kW
*Self-consumption is how much PV energy is used at home and not exported to the grid with
respect to the total energy production.
Energy self-sufficiency is how much PV energy is used at home and not exported to the grid
with respect to the total energy consumption.
String inverter
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
The REACT-4.6-TL (Renewable Energy Accumulator
and Conversion Technology) is a PV single-phase grid
connected inverter able to store energy in a 2.0kWh useful
capacity Li-Ion battery integrated within the same product
enclosure, expandable up to 3x
All features found in our family of string inverters are
maintained: double fast MPPT, broad input voltage range,
top class efficiency with TL topology, compactness,
installation flexibility
REACT-3.6/4.6-TL
REACT-3.6-TL
REACT-UNO-3.6-TL
System components
REACT-BAT-AP1
REACT-MTR-1PH (or -3PH)
REACT-UNO-3.6-TL
REACT-UNO-4.6-TL
REACT-4.6-TL
REACT-UNO-4.6-TL
600 V
200 V (adj. 120...350 V)
0.7 x V start...580 V (min 90 V)
360 V
5000 W
6000 W
2
2500 W
Linear derating [520VVMPPT580V]
3000 W
Linear derating [520VVMPPT580V]
160520 V
180520 V
12 A / 24 A
13.5 A / 27 A
15.0 A
2
Tool Free PV connector WM / MC4
Yes, from limited current source
Yes
According to local standard
25 A / 660 V
3000 W
3000 W
Single-phase
3600 W
3600 W
4000 VA
4600 W
4600 W
5100 VA
230 V
180...264 V
1)
19 A
24 A
50 Hz / 60 Hz
47...53 Hz / 5763 Hz 2)
> 0.995, adj. 0.9 @ P acr, 0.8 with max Smax
< 2%
Screw terminal block, cable gland M25
According to local standard
25 A
32 A
2 (L - N / L - PE)
2.5kWh
8kWh
10kWh
2kWh
2kWh
8+2 = 80%
Energy self-sufficiency = 12.5
= 50%
Self-consumption = 8+2
20
The AC voltage range may vary depending on specific country grid standard
2)
The Frequency range may vary depending on specific country grid standard
REACT-UNO-3.6-TL
REACT-UNO-4.6-TL
97.1%
96.6% / 94.0%
Integrated
Integrated, WiFi certified
Mobile APP, Webserver UI, Graphic display
PVI-USB-RS232_485 (opt.)
-20...+55C
+5...+35C
0...+40C
-10...+45C
095% non condensing
2000 m / 6560 ft
Indoor with ventilation openings
IP54 (inverter), IP21 (battery pack)
Natural
740 mm x 983 mm x 229 mm
740 mm x 490 mm x 229 mm
< 60 kg
< 30 kg
Wall bracket
Transformerless
CE
EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3,
EN 61000-3-2, EN 61000-3-3, EN61000-3-11, EN61000-3-12, EN60529
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, VFR2014
Output for GOGO-box (opt.)
Optional, automatic or manual restart, even with battery discharged
Services to grid enabled by factory, can be disabled
Optional special version, AC bus storage
Remark. Features not specifically listed in the present data sheet are not included in the product
Router + Modem
Mobile App
Wi-Fi
network
CLOUD
REACT-BAT-AP1
Panasonic
Li-Ion
1.5 kW / 1.8 kW
1.1 kW
2 kWh (6 kWh, with 3x battery pack)
> 4500 cycles
10 years ( Max 9 MWh discharged)
EN62109-1, EN62109-2, EN50178, compliance to applicable requirements of
EN60950-1, EN61000-6-2, EN61000-6-3, UN38.3, UN34.80
REACT-MTR-1PH (or -3PH)
Necessary for optimum battery energy management
Order separately REACT-MTR-1PH or REACT-MTR-3PH
P/ Q/ A/ V/ I
<1%, 1%
30 A, up to 5 Adc tolerant
1 or 3
110-230 V / 85...265 V
50-60 Hz / 45...65 Hz
Integrated, <1 W
4kVrms (for 1 minute) between AC measuring ports and communication port
CAT III,
Front IP40, screw terminals IP20
DIN 43880 Rail, 3 or 4 modules wide
-20...+55C
IEC 61010-1, IEC 61326-1
IN1.1(+)
Inverter
(DC/AC)
Bulk caps
Switch
IN1.2(+)
IN1.1(-)
IN1.2(-)
Line
filter
AC
Backup
Output
Grid parallel
relay
L
AC
Output
N
MPPT 2
(DC/DC)
IN2.1(+)
IN2.2(+)
PE
Residual current
detection
IN2.1(-)
IN2.2(-)
Control circuit
RS485
+ T/R
- T/R
RTN
DC/DC
DSP
contr.
DC/AC
DSP
contr.
Remote control
+R
-R
Alarm
N.C
N.O
C
Charger/
Discharger
(DC/DC)
Modbus
RS485
(Meter)
RS485
RTU
Go Go Box
Protection
STOP
RTN
- T/R
+ T/R
RTN
- T/R
+ T/R
WIFI
REACT-BAT
Battery
pack
Protection
BMS
Optional REACT-BAT
Battery
pack
Protection
BMS
Central inverters
Highlights
High total performance
Modular and compact product design
Extensive DC and AC side protection
Full grid support functionality
Fast and easy installation
Complete range of industrial-type data communication
options, including remote monitoring
Life cycle service and support through ABBs extensive
global service network
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
-0100kW-A
-0250kW-A
-0315kW-B
-0500kW-A
-0630kW-B
-0875kW-B
-1000kW-C
100 kW
250 kW
315 kW
500 kW
630 kW
875 kW
1000 kW
Input (DC)
120 kWp
300 kWp
378 kWp
600 kWp
756 kWp
1050 kWp
1200 kWp
450 to 825 V
450 to 825 V
525 to 825 V
450 to 825 V
525 to 825 V
525 to 825 V
600 to 850 V
1000 V
1000 V
1000 V
1100 V
1100 V
1100 V
1100 V
245 A
600 A
615 A
1145 A
1230 A
1710 A
1710 A
2, 4, 8 (+/-)
2, 4, 8 (+/-)
4 to 15 (+/-)
4 to 15 (+/-)
8 to 20 (+/-)
8 to 20 (+/-)
1)
1 (+/-) /4
2)
Output (AC)
Nominal power (PN(AC)) 3)
100 kW
250 kW
315 kW
500 kW
630 kW
875 kW
1000 kW
100 kW
250 kW
345 kW
600 kW
700 kW
1050 kW
1200 kW
96 kW
240 kW
300 kW
475 kW
600 kW
830 kW
950 kW
195 A
485 A
520 A
965 A
1040 A
1445 A
1445 A
300 V
300 V
350 V
300 V
350 V
350 V
400 V
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
3)
5)
Output frequency
Harmonic distortion, current
Distribution network type
6)
7)
< 3%
< 3%
< 3%
< 3%
< 3%
< 3%
< 3%
TN and IT
TN and IT
TN and IT
TN and IT
TN and IT
TN and IT
TN and IT
Efficiency
98.0%
98.0%
98.6%
98.6%
98.6%
98.7%
98.8%
97.5%
97.6%
98.3%
98.2%
98.4%
98.5%
98.6%
310 W
310 W
310 W
490 W
490 W
650 W
650 W
60 W
60 W
60 W
65 W
65 W
65 W
65 W
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
230 V, 50 Hz
1030/2130/690
1830/2130/680
1830/2130/680
2630/2130/708
2630/2130/708
3630/2130/708
3630/2130/708
550
1100
1100
1800
1800
2320
2320
Maximum
Euro-eta
8)
8)
Power consumption
9)
3)
4)
1)
2)
10)
7)
8)
9)
5)
6)
+/- 10%
At nominal power
Inverter side must be IT type
Without auxiliary power consumption at min UDC
115 V, 60 Hz optional
10)
Filter
EMC
filter
EMC
filter
Filter
EMC
filter
EMC
filter
Control
and
monitor
Control
and
monitor
-0100kW-A
-0250kW-A
-0315kW-B
-0500kW-A
-0630kW-B
-0875kW-B
-1000kW-C
100 kW
250 kW
315 kW
500 kW
630 kW
875 kW
1000 kW
Environmental limits
Degree of protection
IP42
IP42
IP42
IP42
IP42
IP42
IP42
-15 to +40C
-15 to +40C
-15 to +45C
-15 to +50C
-15 to +45C
-15 to +50C
-15 to +50C
+50C
+50C
+55C
+55C
+55C
+55C
+55C
15 to 95%
15 to 95%
15 to 95%
15 to 95%
15 to 95%
15 to 95%
15 to 95%
2000 m
2000 m
14)
2000 m
14)
4000 m
4000 m
4000 m
4000 m
75 dBA
15)
75 dBA
15)
14)
75 dBA
1300 m3/h
2500 m3/h
75 dBA
2500 m 3/h
15)
5000 m 3/h
75 dBA
75 dBA
15)
5000 m 3/h
15)
7950 m 3/h
75 dBA
15)
7950 m 3/h
Protection
Ground fault monitoring 16)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Grid monitoring
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Anti-islanding
Yes
Yes
Yes
Yes
Yes
Yes
Yes
DC reverse polarity
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Analog inputs/outputs
1/2
1/2
1/2
1/2
1/2
1/2
1/2
3/1
3/1
3/1
3/1
3/1
3/1
3/1
Fieldbus connectivity
Product compliance
Safety and EMC
Certifications and approvals
17)
18)
11)
15)
12)
16)
High efficiency
Low auxiliary power consumption
Efficient maximum power point tracking
Long and reliable service life of at least 20 years
Extensive protections
Proven technology
Junction box
with monitoring
Central inverter
Ethernet adapter
Internet
Fieldbus
Local PC
Modbus
MV
transformer
Mobile
Server
Remote PC
MV power network
Electricity
Data
Options
Integrated and flexible DC input extension cabinets
Cabinet heating
I/O extensions
DC grounding (negative and positive)
Fieldbus and Ethernet connections
Current measurement to each DC input
Warranty extensions
Solar inverter care contracts
Accessories
Solar array junction boxes with string monitoring
Remote monitoring solutions
ULTRA-700.0/1050.0/1400.0-TL OUTD
700 to 1400 kW
The largest solar power inverter in the ABB product range, the
new ULTRA-1400.0 unit is designed with large utility-grade
installations in mind.
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Maximum DC input voltage up to 1000 V (optional 1100V),
high design flexibility and reduced DC distribution losses
for large-scale PV plants
Reduced susceptibility to a single fault; in case of a
component failure, a maximum of 350kW will be lost
Integrated DC and AC distribution and protection; fully
equipped for connection, additional accessories not
required
Direct transformerless conversion to the 690 Vac output
reduces AC distribution cost
Extended MPPT input voltage range
Efficiency [%]
96
95
94
93
585
92
680
91
90
800
0,0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
ULTRA-700.0-TL
ULTRA-1050.0-TL
470...900 V
Linear derating from max to
15 kW [850 V<V MPPT<900 V]
560 kW @ 470 V
585...850 V @ 700 kW
645...850 V @ 780 kW
2
1388 A (2 x 694 A)
10
20 x 50 mm2 ... 240 mm2(M12)
ULTRA-1400.0-TL
470...900 V
Linear derating from max to
30 kW [850 V<V MPPT<900 V]
1120 kW @ 470 V
585...850 V @ 1400 kW
645...850 V @ 1560 kW
4
2776 A (4 x 694 A)
20
40 x 50 mm2 240 mm2(M12)
780 kW
780 kVA
650 A
1036 A
Three-phases 3W+PE
1170 kW
1170 kVA
690 V
621...759 V 1)
975 A
1554 A
50/60 Hz
47...53 / 57...63 Hz 2)
> 0.995 (adj. 0.90) (adj. 0.10)
< 3% (@ Pac,r)
6 x 240 mm2 (M12)
According to local standard
Type II voltage surge protection
Yes
Yes
3x450 A / 200 kA
1560 kW
1560 kVA
1300 A
2072 A
PV array 1(+)
PV array 2(+)
PV array 3(+)
PV array 4(+)
DC load
break switch
OVR
Bulk
caps
module
DC / AC
inverter
module
Line
filter
module
AC
contact
module
PV array 5(+)
AC
fuse
EMI
filter
PV array 1(-)
PV array 2(-)
PV array 3(-)
Control circuit
PV array 4(-)
PV array 5(-)
DC load
break switch
OVR
Bulk
caps
module
DC / AC
inverter
module
Line
filter
module
AC
contact
module
AC
fuse
EMI
filter
AC Circuit Breaker
(optional)
Control circuit
IMD
R
S Main AC power
connection
T
DC load
break switch
OVR
Bulk
caps
module
DC / AC
inverter
module
Line
filter
module
PE
AC
contact
module
AC
fuse
EMI
filter
Control circuit
PV array 17(+)
PV array 18(+)
PV array 19(+)
To each
350.0Kw module
PV array 16(+)
DC load
break switch
OVR
Bulk
caps
module
DC / AC
inverter
module
Line
filter
module
PV array 20(+)
AC
contact
module
AC
fuse
EMI
filter
PV array 16(-)
24 VDC
24 VDC
- 5 VDC
R
S
T
N
AUX power
connection
PE
PV array 17(-)
PV array 18(-)
AC circuit
breaker
Control circuit
400 VAC
control circuit
PV array 19(-)
PV array 20(-)
ULTRA-700.0-TL
ULTRA-1050.0-TL
ULTRA-1400.0-TL
98.7% 3)
98.2% / 98.0% 3)
< 110 W
3 x 400 Vac +N, 50/60 Hz
< 0.60% of Pac,r
< 0.06% of Pac,r
9 kHz
< 90 W
< 0.50% of Pac,r
< 0.05% of Pac,r
< 180 W
< 0.50% of Pac,r
< 0.05% of Pac,r
PVI-USB-RS232_485 (opt.)
PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
PVI-STRINGCOMB (opt.)
TFT LCD 5.7
-20...+ 60C/-4...140F with derating above 50C/122F
-40...+ 60C/-40...140F with derating above 50C/122F (opt.)
0...100% condensing
< 78 dB(A) @ 1 m
2000 m / 6560 ft
2000 m / 6560 ft
2000 m / 6560 ft
IP 65
Passive liquid
Not applicable
2920 mm x 3020 mm x 1520 mm / 2920 mm x 3720 mm x 1520 mm / 2920 mm x 4420 mm x 1520 mm /
114.9 x 118.9 x 59.9
114.9 x 146,5 x 59.9
114.9 x 174,0 x 59.9
< 3000 kg / 6613 lbs
< 3800 kg / 8377 lbs
< 4600 kg / 10141 lbs
< 55 kg / 121 lbs
No
CE (50 Hz only)
EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, EN61000-6-2, EN61000-6-4
CEI-0-16, BDEW, P.O.12.3, Ordinul 30/2013
The AC voltage range may vary depending on specific country grid standard
The Frequency range may vary depending on specific country grid standard
3)
Power consumption of the auxiliary services not included
Remark. Features not specifically listed in the present data sheet are not included in the product
For the available options refer to the configuration module and verify with ABB technical support
1)
2)
Turnkey stations
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Proven technology and reliable components
Compact and robust design
High total efficiency
Modular and serviceable system
Double-stage air pre-filtering for reduced maintenance
Global life cycle services and support
Accessories
Solar array junction boxes with string monitoring
Remote monitoring solutions
Warranty extensions
Solar inverter care contracts
Options
MV AC output voltages (6 to 24 kV)
Different MV switchgear configurations
Air-insulated MV switchgear
Optional liquid-filled and dry-type transformers
I/O extensions
DC grounding (negative and positive)
Fieldbus and Ethernet connections
Auxiliary power supply from main power connections
Solar inverters
ABB solar inverters are the result of decades of industry
experience and the use of proven frequency converter
technology. As such the solar inverters provide a highly
efficient and cost-effective way to convert the direct current,
generated by solar modules, into high-quality and CO2 -free
alternating current. Two ABB central inverters are used in the
ABB megawatt station. The inverters provide high efficiency
conversion with low auxiliary power consumption.
Transformer
The ABB megawatt station features an ABB vacuum cast coil
dry-type transformer. The transformer is designed to meet the
reliability, durability, and efficiency required in PV applications.
It is specifically designed and optimized for ABB solar
inverters to provide the best performance throughout the
lifetime of the plant.
The transformer is environmentally safe, having no volatile
liquids that can leak, and it carries no fire or explosion
risk. It provides excellent mechanical and short-circuit
characteristics.
Switchgear
ABB offers a complete range of medium voltage switchgear
for secondary distribution, including air-insulated and gasinsulated switchgear.
The ABB megawatt station is equipped, as standard, with
the widely proven ABB SafeRing, SF6-insulated switchgear.
A sealed steel tank with constant atmospheric conditions
ensures a high level of reliability as well as personnel safety.
The virtually maintenance-free
system comes in a compact and flexible
design that allows for a versatile switchgear configuration.
As an option ABBs gas-insulated SafePlus and air-insulated
Unisec switchgear are also available.
PVS800-MWS-1000kW-20
PVS800-MWS-1250kW-20
1 MW
1.25 MW
Input (DC)
Maximum input power (P PV, max)
DC voltage range, mpp (U DC, mpp)
Maximum DC voltage (U DC, max)
1)
2 600 kW
2 760 kW
450 to 825 V
525 to 825 V
1100 V
1100 V
2 1145 A
2 1230 A
< 3%
< 3%
2 8 (+/-)
2 8 (+/-)
1000 kW
1250 kW
28.9 A
36.1 A
Output (AC)
Nominal AC output power (P AC, N)
Nominal AC current (I AC, N)
Nominal output voltage (U AC,N)
2)
Output frequency
Harmonic distortion, current
3)
20 kV
20 kV
50/60 Hz
50/60 Hz
< 3%
< 3%
Yes
Yes
PVS800-57-0500kW-A
PVS800-57-0630kW-B
ABB Vacuum cast coil dry-type
4)
5)
Efficiency
Maximum
Euro-eta
6)
6)
(including transformer)
(including transformer)
If DC voltage is > 1000 V, the inverter will not be damaged, but will not start
Voltages between 6 and 24 kV available as an option
3)
At nominal power
4)
Other ABB transformer types available as an option
5)
Other ABB switchgear types available as an option
6)
Efficiency without auxiliary power consumption, at lowest DC voltage
1)
2)
97.8%
97.8%
97.1%
97.3%
Filter
EMC filter
Filter
EMC filter
EMC filter
1: PVS800-MWS
EMC filter
Control
and
monitoring
3
Control
and
monitoring
20 kV
2: PVS800-MWS
Filter
EMC filter
Filter
EMC filter
EMC filter
MV grid
connection
EMC filter
Control
and
monitoring
3
Control
and
monitoring
20 kV
PVS800-MWS-1000kW-20
PVS800-MWS-1250kW-20
1 MW
1.25 MW
< 1200 W
< 1200 W
Power consumption
Own consumption in operation
7)
< 140 W
< 140 W
3 ~ 400 V/50 Hz
3 ~ 400 V/50 Hz
20 t
21 t
-20 to +40C
-20 to +40C
7)
8)
9)
+50C
+50C
15 to 95%
15 to 95%
2000 m
2000 m
6720 m 3/h
6720 m3/h
Fieldbus connectivity
Product compliance
Conformity
Certifications and approvals
Grid support
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Proven technology and reliable components
Standard and robust design
Protected working interior
Modular and redundant system
Easy connection to a MV station
Extendable manufacturing footprint with fast deliveries
Embedded auxiliary power distribution system
Double-stage air pre-filtering for reduced maintenance
Life cycle service and support through ABBs extensive
global service network
Accessories
Solar array junction boxes with string monitoring
Remote monitoring solutions
Warranty extensions
Solar inverter care contracts
Options
Auxiliary transformer
Upgrades to match environmental conditions
Solar inverters
ABBs PVS800 central inverters are the result of decades
of industry experience and the use of proven frequency
converter technology. As such the central inverters provide
a highly efficient and cost-effective way to convert the direct
current generated by solar modules into high-quality and CO2free alternating current. Two ABB central inverters are used in
the ABB inverter station. The inverters provide high efficiency
conversion with low auxiliary power consumption.
2)
3)
PVS800-IS-1750kW-B
1.75 MW
PVS800-IS-2000kW-C
2 MW
2 1050 kW
525 to 825 V
1100 V
2 1710 A
2 12 (+/-)
2
2 1200 kW
600 to 850 V
1100 V
2 1710 A
2 12 (+/-)
2
2 875 kW
2 1000 kW
2 830 kW
2 1050 kW
2 950 kW
2 1200 kW
2 1445 A
2 1445 A
350 V
50/60 Hz
<3%
Yes
400 V
50/60 Hz
<3%
Yes
Inverter station
MV substation
MV network
connection
EMC
filter
Filter
EMC
filter
2 central inverters
Control
and
monitor
AUX
cabinet
AUX
voltage
EMC
filter
Filter
EMC
filter
AUX
transformer
(opt.)
Control
and
monitor
PVS800-IS-1750kW-B
1.75 MW
PVS800-IS-2000kW-C
2 MW
98.7%
98.5%
98.8%
98.6%
<1400 W
<100 W
3/N/PE AC 400 V 50 Hz
6058 x 2896 x 2438 mm
10 t
IP54
-20C to +45C
+55C
15 to 95%
6)
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Developed to be used jointly with outdoor type inverters
(ULTRA Series)
Designed and built for outdoor use in all environmental
conditions
Completely removable protection grid for simplified
installation and maintenance
ULTRA-MVC-S
1)
ULTRA-MVC-770.0-S
ULTRA-MVC-1160.0-S
ULTRA-MVC-1550.0-S
ULTRA-700.0-TL
ULTRA-1050.0-TL
ULTRA-1400.0-TL
LV distribution panel
LV connections from the inverter 1)
Low voltage AC power distribution from inverters
to trafo (magnetothermic switch)
Device for insulation permanent control 2)
Energy meters
3)
Medium-voltage transformer
Construction
Oil-sealed
4)
800 kVA
1250 kVA
1600 kVA
2 x 2.5%
1
ONAN
Mineral oil
Dyn11
6%
Refer to transformer datasheet
IP65
Mv switchgear
Configuration
Trafo protection
Auxiliary supply
Auxiliary supply voltage
Low voltage distribution for auxiliary functions
Supply for customer devices
3x400 Vac + N, 50 Hz
Yes (include dedicated and protected supply lines for: inverter, data logger, lighting, AC socket, spare)
Single-phase socket with RCD protection, 16 A/230 V/50 Hz (Id = 0,03 A)
Dry
15 kVA (690/400 V)
Air
Dyn11
<130 W / <460 W
Circuit breaker
Cooling
Cooling type (switch gear cabinet)
LBS
ES1
ULTRA-1400.0-TL
(1556kW@cos=1)
ES
ES
0,69kV / XXkV
L1
L2
///
L3
ES2
MV trafo 1600kVA
Inv. Aux
MV
LV distribution
for AUX functions
LV distribution
for AUX functions
(UPS section)
Datalogger
Lighting
Inv. Aux 1
Fan
Inv. Aux 2
AUX QMT
Extractor fan
Aux trafo
protection
fuses
AUX QBT
AUX QMT-UPS
2P Spare
AUX QBT-UPS
2P Socket
Aux trafo
U
V
W
N
Therm. unit
trafo
UPS
U
V
W
N
3x400V+N 3x690V
1)
Environmental parameters
Full power operating temperature range
Relative humidity (non-condensing)
Maximum operating altitude without deranting 5)
Communication/user interface and system monitoring
Communication port (PC / Data logger)
Communication to inverter
Remote communication (optional)
UPS (optional)
UPS for protection and monitoring system
Lighting
Mechanical characteristics
Dimensions (W x H x D)
Body material (MV switch gear cabinet)
Oil collecting tank
Environmental protection rate
(MV switch gear cabinet)
Environmental protection rate
(trafo protection grid)
ULTRA-MVC-770.0-S
ULTRA-MVC-1160.0-S
ULTRA-MVC-1550.0-S
ULTRA-700.0-TL
ULTRA-1050.0-TL
ULTRA-1400.0-TL
-25C...+45C
95%
1000
1 x RS485
1 x RS485
VSN700 Data Logger
2 kVA, 10
Fluorescent lamps T8 2x18 W,
electronic supplier for emergency lighting with Ni-Cd hermetic battery (1 h autonomy)
5200 x 2800 x 2300 mm
Metal housing with double metal panel insulated by polyurethanic foam
110% of oil content
IP43 (IP54 optional)
IP1XA
4)
2)
Optional
LV electrical panel with automatic circuit breaker
Energy meters (one for each inverter)
LV distribution panels for auxiliary functions
Auxiliary transformer
Single / double feeder switchgear
Monitoring system VSN700 Data Logger
UPS 2 kVA for monitoring and protection system
Hot climate package 50C
IP54 ambiental protection degree
IP54 ambiental protection degree + sand trap filter
ULTRA-MVC-S
Footprint ULTRA-MVC-3110.0-S
PROTECTION NET IP10
REAR VIEW
2720
FRONT VIEW
2300
5130
REMOVABLE FRAME
SPILL CONTAINMET
PLANT
71
SECTION A-A
1974
1822
76
76
259
3156
DOUBLE DOOR
1650x2400h
2489
2720
461
300
72
Optional IP 54
Optional KIT SAND TRAP
140
20
Q.S.
630
TRAFO
AUX
50 KVA
(OPTIONAL)
UPS
2 kVA
ONLY RING
CONFIGURATION
5000
Q.TRAUX
QMT
ABB
73
OIL TRAFO
..... KVA
192
905
1330
1930
A
300
2276
DOOR
5130
DOOR
1000x2200h
ULTRA-MVC-1940.0-S
ULTRA-700.0-TL
1)
ULTRA-1050.0-TL
ULTRA-MVC-2330.0-S
ULTRA-MVC-2720.0-S
ULTRA-1050.0-TL
2x ULTRA-1050.0-TL
ULTRA-1400.0-TL
ULTRA-MVC-3110.0-S
2x ULTRA-1400.0-TL
LV distribution panel
Max 12 x 3 x 240 mm2
3)
Medium-voltage transformer
Construction
Oil-sealed
4)
2000 kVA
2500 kVA
3150 kVA
3150 kVA
2 x 2.5%
1
ONAN
Mineral oil
Dyn11
6%
Refer to transformer datasheet
IP65
Mv switchgear
Configuration
Trafo protection
Auxiliary supply
Auxiliary supply voltage
Low voltage distribution for auxiliary functions
Supply for customer devices
3x400 Vac + N, 50 Hz
Yes (include dedicated and protected supply lines for: inverter, data logger, lighting, AC socket, spare)
Single-phase socket with RCD protection, 16 A/230 V/50 Hz (Id = 0,03 A)
Dry
25 kVA (690/400 V)
Air
Dyn11
<200 W / <650 W
Circuit breaker
Cooling
Cooling type (switch gear cabinet)
LBS
ES1
ULTRA-1400.0-TL
(1556kW@cos=1)
ES
0,69kV / XXkV
MV
ES2
///
MV trafo 3150kVA
Inv. Aux1
MV
ULTRA-1400.0-TL
(1556kW@cos=1)
LV distribution
for AUX functions
LV distribution
for AUX functions
(UPS section)
Inv. Aux2
ES
Lighting
Aux trafo
protection
fuses
Inv. Aux 1
Fan
Inv. Aux 2
AUX QMT
Extractor fan
AUX QBT
Datalogger
2P Spare
AUX QMT-UPS
2P Socket
AUX QBT-UPS
U
V
W
N
Therm. unit
trafo
UPS
U
V
W
N
Aux trafo
3x400V+N 3x690V
ULTRA-MVC-1940.0-S
1)
Environmental parameters
Full power operating temperature range
Relative humidity (non-condensing)
Maximum operating altitude without deranting 5)
Communication/user interface and system monitoring
Communication port (PC / Data logger)
Communication to inverter
Remote communication (optional)
UPS (optional)
UPS for protection and monitoring system
Lighting
Mechanical characteristics
Dimensions (W x H x D)
Body material (MV swithc gear cabinet)
Oil collecting tank
Environmental protection rate
(MV switch gear cabinet)
Environmental protection rate
(trafo protection grid)
ULTRA-700.0-TL
ULTRA-1050.0-TL
ULTRA-MVC-2330.0-S
ULTRA-MVC-2720.0-S
ULTRA-1050.0-TL
2x ULTRA-1050.0-TL
ULTRA-1400.0-TL
ULTRA-MVC-3110.0-S
2x ULTRA-1400.0-TL
-25C...+45C
95%
1000
1 x RS485
1 x RS485
VSN 700 Data Logger
2 kVA, 10
Fluorescent lamps T8 2x18W, electronic supplier for emergency lighting with Ni-Cd hermetic battery
(1 h autonomy)
5200 x 2800 x 2300 mm
Metal housing with double metal panel insulated by polyurethanic foam
110% of oil content
IP43 (IP54 optional)
IP1XA
4)
For further details, please refer to the specific inverter data-sheet
Other medium voltage levels available on request
2)
5)
Available as inverter option
Contact ABB for application at higher altitudes
3)
Available as inverter option - 4 quadrant MID certified
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
Optional
LV electrical panel with automatic circuit breaker
Energy meters (one for each inverter)
LV distribution panels for auxiliary functions
Auxiliary transformer
Single / double feeder switchgear
Monitoring system VSN700 Data Logger
UPS 2 kVA for monitoring and protection system
Hot climate package 50C
IP54 ambiental protection degree
IP54 ambiental protection degree + sand trap filter
ULTRA-MVC-S
Commercial
Share data with Plant Viewer
and maintain a portfolio with
Plant Portfolio Manager
Utility
Asset management with
Plant Portfolio Manager
in parallel with SCADA
systems
Aurora Vision
Plant Viewer
Plant Viewer is a web based tool designed for residential
customers. Home owners using Plant Viewer can see how
well their solar power plant is operating. They can view plant
information over the course of a day, week, month or year,
without interfering with how the plant is being operated.
It is an easy way for the home owner to demonstrate the
environmental benefits of their home PV plant to family
and friends. Clear and dynamic graphics show how much
potential pollution is being prevented by generating solar
electricity.
Access to Plant Viewer is controlled by the plant installer to
give the home owner as much access to the plant as the
installer wants to provide.
Highlights
Integrates with the full line of ABB monitoring and
communication products to remotely diagnose and address
customer issues
Use established Plant Portfolio Manager or Plant Viewer to
user login account
Use a PC web browser and a favourite mobile device; both
options can be used simultaneously
This solution works with solar power systems selfregistered by homeowners
Integrates with Aurora Vision Plant Management Platform
to enable or disable access to system information
See current and past energy generation values to track
energy production over the life of one or more plants
Mail yourself detailed energy information for further
investigation
Displays weather information from weather stations
installed at the solar power plant site
Works on iOS and Android devices that support iOS 8.x
and Android 4.x
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
VSN700-01
String inverters
Internet
Plant Viewer
Highlights
All VSN700 Data Logger models include:
Data management system with serial and Ethernet ports
for data and event logging
Quick installation and fast plug-n-play commissioning with
device discovery mechanism
Network Provisioning with dynamic IP addressing (DHCP
client and server)
Reliable and secure transmission of operational data to
Aurora Vision Plant Management Platform
Remote configuration and management capabilities,
including firmware upgrades over the Internet using Plant
Portfolio Manager
Simple end-user UI using Plant Viewer
Communication interfaces
Serial port interface
Physical limitation of 32 (reduced by poll rate, inverter data set size and logger type)
Fieldbus cable
RS-485 Shielded Twisted Pair. Recommend Belden # 1120A cable or # 3106A for 3 conductors
Ethernet port 0
Ethernet port 1
Ethernet connections
Communication protocols
Plant fieldbus protocols
LAN/WAN protocols
Local storage
Log data for 30 days based on 15-minute intervals (Days logged may be reduced by intervals shorter than 7 minute)
Upgradeability
Field upgradable over the Internet or locally via USB memory stick
Power Supply
AC power supply input
12 VDC, 1 A
Environmental parameters
Ambient temperature range
0 C - 40C
Environmental protection
IP 20
Relative humidity
<85% Non-condensing
Weight
Mounting system
Accessories
VSN-MGR-DIN
VSN800-12
Weather Station with sensors: ambient temperature, panel temperature, global irradiance
VSN800-14
Weather Station with sensors: ambient temperature, panel temperature, global irradiance, plane of array irradiance,
wind speed and direction
Compliance
Emissions
FCC Part 15 Class B, CISPR 22, EN 55022 Conducted and Radiated Emission
Immunity
EN55024
1)
Remark. Features not specifically listed in the present data sheet are not included in the product
String inverters
VSN800-14
Weather Station
VSN700-05
or
RS-485
MODBUS TCP or IP
Internet
Plant Viewer
Plant Viewer
for Mobile
SCADA
VSN700-01
Devices Supported
VSN700-03
VSN700-05
1, 3, 5, 15 minute configurable
intervals
No
No
Yes
No
No
Yes
5 x ABB inverters
10 x ABB inverters
VSN-MGR-DIN
VSN800-12
VSN800-14
The VSN300 Wifi Logger Card is easy to install, for new and
most existing string inverters by using the inverters internal
expansion slot.
The local web server in VSN300 Wifi Logger Card adds the
ability to use a standard web browser to access inverter data.
The built-in IP networking connectivity and innovative WiFi commissioning techniques enable this card to be easily
configured for most Wi-Fi networks and access points
without installing any additional external devices.
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
The Wi-Fi Certified mark assures interoperability with
IEEE 802.11b/g/n networks over the 2.4 GHz band
Easily installed on new and existing UNO and TRIO string
inverters
IEEE 802.11b/g/n (2.4 GHz) support
Local, remote monitoring in one solution
High performance non-volatile data logging
High-speed inverter data exchange through Hyperlink
[where available]
Communication interfaces
Inverter interface
User interface
Hyperlink (CAN@1 Mbps + RS485@115 kBaud) / Legacy (Serial link TTL @ 19.2 KBaud)
Wi-Fi Certified IEEE 802.11 b/g/n (2,4 GHz)
Communication protocols
Protocolli LAN/WAN
Monitoring
Web user interface (WUI)
Local monitoring
Remote monitoring
Integrated
Wirelessly allowed via any Wi-Fi device connecting the integrated WUI or running Plant Viewer for Mobile
Plant Portfolio Manager / Plant Viewer / Plant Viewer for mobile
Advanced functionalities
Remote O&M operations
Smart grid functionalities
2)
2)
2)
Power supply
DC power supply output
~2W
Environmental parameters
Ambient temperature range
[-20; +85]C
Environmental protection
IP 20
Relative humidity
<85% Non-condensing
Weight
Mounting System
Compliance
Marking
Emissions
Immunity
EN55024
1)
2)
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
Internet
Router WI-FI
1)
Monitoring
UNO-2.0
Yes
No
UNO-2.5
Yes
No
UNO-7.6
Yes
Yes
UNO-8.6
Yes
Yes
PVI-3.0
Yes
No
PVI-3.6
Yes
No
PVI-3.8
Yes
No
PVI-4.2
Yes
No
PVI-4.6
Yes
No
PVI-5000
Yes
No
PVI-6000
Yes
No
PVI-6.0
Yes
No
PVI-8.0
Yes
No
PVI-10.0
Yes
No
PVI-12.5
Yes
No
TRIO-5.8
Yes
Yes
TRIO-7.5
Yes
Yes
Yes
TRIO-8.5
Yes
TRIO-20.0
Yes
No
TRIO-27.6
Yes
No
Inverters parameters setting and inverters firmware upgrade (from FW version 1.8.x)
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Commercial application with VSN730 System Monitor using VSN800 Weather Station
TRIO-20.0/27.6 or PVI-10.0/12.0
VSN800
Weather Station
VSN730
System Monitor
RS-485
Internet
Plant Portfolio Manager
Highlights
VSN700-03 or VSN700-05 Data Logger
Enclosed in a painted, steel NEMA 4/ IP65 enclosure
85 VAC to 305 VAC / 24 VDC, 1 A power supply
Supports 10 ABB string inverters and a VSN800 Weather
Station
RS-485 surge protection
Easy installation
Remote performance and asset management through the
Aurora Vision Plant Management Platform
Plant Viewer
Plant Viewer
for Mobile
VSN730-05
Platform
Devices supported
Monitoring
Inverter control
Communication interfaces
Serial port interface
RS-485 port 1 configuration
RS-485 port 2 configuration
Maximum devices per serial port
Fieldbus cable
Ethernet port 0
Ethernet port 1
Ethernet connections
Communication protocols
Plant fieldbus protocols
LAN/WAN protocols
Data logging specifications
Data sampling rate
Logging
Local storage
Upgradeability
Communications surge protection
Replaceable cartride
Power supply
DC power supply input
DC power supply output
Environmental protection rating
Ambient temperature range
Environmental protection rating
Relative humidity
Mechanical parameters
Dimensions H x W X D
Enclosure options
Weight
Mounting System
Compliance
Safety
Marking
Altitude
Emission
Immunity
Telecom
1)
Consult latest supported devices list
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
Commercial application with VSN730 System Monitor using individual weather sensors
TRIO-20.0-TL or TRIO-27.6-TL
VSN730
System Monitor
RS-485
Individual sensor
Internet
Plant Viewer
Plant Viewer
for Mobile
VSN730 - Accessories
VSN800-12
VSN800-14
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Utility application with VSN750 Plant Manager 10MW installation example
Copper Ethernet
ULTRA or
PVS800
Combiners
ULTRA or
PVS800
VSN700-05
Revenue
Grade
Meter
Modbus
Combiners
ULTRA or
PVS800
VSN750
Plant Manager
Revenue
Grade
Meter
Modbus
VSN800
Combiners
VSN700-05
Revenue
Grade
Meter
Modbus
Fiber
Ethernet
Fiber
Ethernet
Modbus TCP
SCADA Interface
Copper Ethernet
ULTRA or
PVS800
Combiners
ULTRA or
PVS800
VSN700-05
Revenue
Grade
Meter
Modbus
Combiners
VSN750
Plant Manager
Revenue
Grade
Meter
Modbus
ULTRA or
PVS800
Combiners
VSN700-05
Revenue
Grade
Meter
Modbus
VSN800
Highlights
VSN700-05 Data Logger
RS-485 repeater with galvanic isolation
85 VAC to 305 VAC / 24 VDC, 1.25 A power supply
NEMA 4 / IP65 enclosure
Revenue grade energy metering options
Copper, Fiber, Cellular and RS-485 communications
options
Easy installation
Monitoring support for all ABB inverters and many meters,
combiners and weather stations
VSN700-05
VSN750-N00110
VSN700-05
VSN750-N05110
VSN700-05
VSN750-N00130
VSN700-05
VSN750-N05030
VSN700-05
VSN700-05
VSN750-N06060
Ethernet Switch
Cell Router
Yes
5 Port
VSN750-N10010
VSN700-05
Veris E51C2
VSN750-N10110
VSN700-05
Veris E51C2
VSN750-N15110
VSN700-05
Veris E51C2
VSN750-N10130
VSN700-05
Veris E51C2
VSN750-N15030
VSN700-05
Veris E51C2
VSN750-N10030
VSN700-05
Veris E51C2
Pwr Supply
1 port
Yes
1 port
Yes
Yes
1 port
Yes
Yes
3 port
Yes
5 Port
3 port
Yes
4 Port Copper,
2 Port Fiber
(2) 3 port
Yes
Yes
5 Port
1 port
Yes
1 port
Yes
Yes
1 port
Yes
Yes
3 port
Yes
5 Port
3 port
Yes
3 port
Yes
Platform
Devices supported
Monitoring
Inverter control
All ABB devices, third-party meters and other modbus devices (Consult latest supported list)
Power/Energy generation and demand, Inverter Direct, Environmental Sensors *
Power reduction, reactive power, COS by Modbus TCP (Available commands are inverter dependent)
Communication interfaces
Serial port interface
RS-485 port 1 configuration
RS-485 port 2 configuration
Maximum devices per serial port
Fieldbus cable
RS-485 shielded twisted Pair. Recommend Belden # 1120A cable or # 3106A for 3 conductors
Ethernet port 0
Ethernet port 1
Ethernet connections
Communication protocols
Plant fieldbus protocols
LAN/WAN protocols
Local storage
Log data for 30 days based on 15-minute intervals. (Days logged may be reduced by intervals shorter than 7-minute)
Upgradeability
Field upgradable over the Internet or locally via USB memory stick
Ethernet switch
CAT-5 connections
Fiber connections
Managed
Unmanaged
100 meters
2 km
Cell router
Network
Internet connection
Antenna connection
Power supply
DC power supply input
DC power supply output
VSN800
Weather Station
VSN750
Plant Manager
RS-485
Internet
Plant Portfolio Manager
Plant Viewer
Plant Viewer
for Mobile
-40C to 50C
NEMA 4
0 to 100% condensing
Mechanical parameters
Dimensions H x W X D
Enclosure options
Weight
Mounting system
Painted steel
40 lbs (18.2 kg)
Screws through flanges
Compliance
Safety
UL/CSA/EN/IEC 61010-1
Marking
cCSAus / CE
Altitude
Emission
FCC Part 15 Class A, CISPR 22, EN 55022 Conducted and Radiated Emission
Immunity
EN 61000, EN55024
Telecom
FCC Part 68
VSN750 - Accessories
VSN800-12
Weather Station with sensors: ambient temperature, panel temperature, global irradiance
VSN800-14
Weather Station with sensors: ambient temperature, panel temperature, global irradiance, plane of array
irradiance, wind speed and direction
VSN-MGR-AUX-CT100
Current transformer 100 A, 0.333 VAC output, 1% accuracy, solid core, 1.0 window diameter
VSN-MGR-AUX-CT200
Current transformer 200 A, 0.333 VAC output, 1% accuracy, solid core, 1.0'' window diameter
VSN-MGR-AUX-CT200SC
Current transformer 200 A, 0.333 VAC output, 1% accuracy, split core, 1.25 window diameter
VSN-MGR-AUX-CT400SC
Current transformer 400 A, 0.333 VAC output, 1% accuracy, split core, 2.5 x 2.9 window diameter
VSN-MGR-AUX-CT600SC
Current transformer 600 A, 0.333 VAC output, 1% accuracy, split core, 2.5 x 2.9 window
VSN-MGR-AUX-CT800SC
Current transformer 800 A, 0.333 VAC output, 1% accuracy, split core, 2.5 x 2.9 window
VSN-MGR-AUX-CT1000SC
Current transformer 1000 A, 0.333 VAC output, 1% accuracy, split core, 2.5 x 5.50 window
VSN-MGR-AUX-CT1200SC
Current transformer 1200 A, 0.333 VAC output, 1% accuracy, split core, 2.5 x 5.5 window
VSN-MGR-AUX-CT1600SC
Current transformer 1600 A, 0.333 VAC output, 1% accuracy, split core,2.5 x 5.5 window
VSN-MGR-AUX-CT2000SC
Current transformer 2000 A, 0.333 VAC output, 1% accuracy, split core, 2.5 x 5.5 window
VSN-MGR-AUX-CT2400SC
Current transformer 2400 A, 0.333 VAC output, 1% accuracy, split core, 2.5 x 5.5 window
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Block diagram of VSN800 Weather Station
Horizontal
irradiance
sensor
Wind speed
sensor
(CMML model)
12 - 24 Vdc
Panel
temperature
sensor
Analog
input
module
Wind direction
sensor
(CMML model)
RS-485 Modbus;
SunSpec compliant
Plane of array
irradiance sensor
(CMML model)
RS-485
Ambient
temperature
sensor
VSN800-12
VSN800-14
Sensors
Ambient temperature
PV panel temperature
Solar radiation
Number of radiation sensors
Wind direction
WindsSpeed
Communication
Serial port
Terminal block
Recommended cable
Power supply
DC power supply input
Terminal block
Compliance
EMC
Enclosure
Humidity
Physical parameters
Dimensions H x W x D
Weight
Ambient temperature range
Mounting
Remark. Features not specifically listed in the present data sheet are not included in the product
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Highlights
Manual 1000 V output disconnect with lock-out tag-out
Touch-safe fuse holders and live component shields
NEMA 4 / IP65 metal enclosure
Code compliant and certified to either UL 1741 or IEC
50178
Wire management back plate
SunSpec Alliance compliant Modbus communication
interface
Valid for all markets accepting US or EU market
certifications
VSN600-16
16
VSN600-32
24
1000 V
15 A (other sizes are special order)
10x38 gPV
11.25 A
250 A or 400 A
<1% above 4 A, absolute error <0.05 A (<0.02 A above 1 A)
250 A
32
400 A
10 A
#14 - #6 AWG (2.08 mm2 - 13.29 mm2) spring clamp (90C terminals, copper only)
#14 - #6 AWG (2.08 mm2 - 13.29 mm2) spring clamp (90C terminals, copper only)
Up to 1 x 300 mm2 or 2 x 180 mm2
/ Up to 1 x 600 MCM or 2 x 350 MCM
16
Up to 2 x 300 mm2
/ Up to 2 x 600 MCM
Up to 2 x 300 mm2
/ Up to 2 x 600 MCM
1/2 inch (M12) hole provided for single or dual-hole compression lug
24
14 AWG - 4 AWG (2.08 mm2 - 21.14 mm2)
1
Up to 3/0 (95 mm2)
250 A only
180 A
250 A or 400 A
200 A or 270 A
32
400 A only
320 A
Local
controller
Local
controller
Local
controller
AFDI / remote
disconnect
DC disconnect
Output
Wifi
board
External RS-485
DC
switch
remote
control
DC
voltage
sense
Power
supply
SPD
Local
controller
Local
controller
Local
controller
AFDI / remote
disconnect
DC disconnect
Output
MIB
External 24V control
power
External RS-485
Wifi
board
DC
switch
remote
control
DC
voltage
sense
Power
supply
SPD
VSN600-16
VSN600-32
RS-485 2 wire, Modbus RTU, SunSpec Alliance compliant register set (legacy Aurora Protocol available)
#28 - #16 AWG (0.08 mm2 - 1.5 mm 2)
Belden #1120 A or # 3106 A for 3 conductors or equivalent
Wi-Fi CertifiedTM (IEEE 802.11.b/g/n 2.4 GHz) (Modbus TCP)
String current, array voltage 1), internal temperature, surge protection status 1), arc fault status 1)
24 V Nominal, 22-30 V, 1 A
AWG #22 - #14 (0.325 mm2 - 2.08 mm2)
24V transformed from DC string 200 V to 1000 V (no external power needed)
Class II
Drill templates
H4 on inputs, cable glands for output and communication
Multi-entry glands, (3) inputs for every string (Positive, Negative, Ground)
UL 1699B (Type 1)
Red light on top of cabinet and alarm over communication link. Output power removed in case of fault
Tuned to ABB inverters only
Single fusing or dual fusing
Positive, negative or floating
1)
Option dependent
Remark. Features not specifically listed in the present data sheet are not included in the product
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Block diagram of PVI-PMU
Monitoring system
with ABB
proprietary protocol
Supply 24VDC or AC
Analog reactive power control
External RS485
PVI-PMU
RS485
RS485
100% digital
60% active
30% power
0% control
PVI-PMU
15...36 V
24 V
50/60 Hz
18...48 V
24 V
< 10 W
RS485 inverter / RS485 external
Half-Duplex
19200 bps
ABB proprietary
32 1)
0.9
1 k between +5V/+D and RTN/-D
120 2)
100 Vdc 4)
4...20 mA (max 22 mA)
4...20 mA (max 22 mA)
4 3)
15 V
50 mA
100 Vdc 4)
IP 20
-20...+60C
0...95%
53 x 90 x 57 mm
180 g
CE
EN55011; EN61000-6-2
Max 32 X ABB string inverters or 55 kW power modules (PRO-33 and PVS-xxx ABB inverters not supported)
Adjustable
Remark. Features not specifically listed in the present data sheet are not included in the product
1)
3)
2)
4)
Highlights
Converters from ABB proprietary Aurora Protocol to
MODBUS RTU
PVI-RS485-MODBUS-STRING (for ABB string inverters)
PVI-RS485-MODBUS-CENTRAL (for ABB central
inverters)
Converters from ABB proprietary Aurora Protocol to
MODBUS TCP
PVI-RS485-MODBUS-TCP-STRING (for ABB string
inverters)
PVI-RS485-MODBUS-TCP-CENTRAL-xx (for ABB
central inverters)
Up to 32 inverters or 55 kW modules manageable
Multi-drop bus connection allowed for RTU
50 Hz transformer and cables are provided
Active-reactive power control allowed by some Modbus
RTU models
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
Block diagram of PVI-RS485-MODBUS Converter
PVI-RS485-TCP
RS485
Modbus RTU
PVI-RS485-MODBUS
Gateway
Modbus TCP
PVI-RS485-MODBUS
RS485 Half-Duplex
19200 bps not modifiable
ABB Proprietary
32
15...36 V
24 V
50 or 60 Hz
18...48 V
24 V
Remark. Features not specifically listed in the present data sheet are not included in the product
String inverters
PV + Storage
Central inverters
Turnkey stations
Monitoring and
communications
RS485
RS485
RS485
USB 2.0
Personal computer
PVI-USB-RS232_485
2.0
B-Type
selectable via switch
Half-Duplex
Yes
Windows 7, Windows XP, Linux Based
1)
Remark. Features not specifically listed in the present data sheet are not included in the product
Prepurchase
We help our customers to select the right inverter and
services for their applications. This ensures higher yield and
performance of the entire system.
Order and delivery
Orders can be placed through any ABB office or through
ABBs channel partners. Ordering online through the web is
also possible. Our sales and service network offers timely
deliveries, including express delivery.
Installation and commissioning
ABB certified engineers can advise or undertake the
installation and commissioning of the solar inverters.
Con trac t s
al
Technic support
in
Train
g an d l e a r n i n
g
Replacement
and
recycling
Upgrade
and
retrofit
Operation
and
maintenance
Prepurchase
Order
and
delivery
Installation
and
commissioning
Prewired monitoring
and control turnkey
solution
MV switchgear
e.g. ABB SafeRing,
SafePlus and UniSec.
Transformers
Dry-type and liquid-filled
transformers
Asynchronous and
brushless motors
M3AA, 9C
Programmable logic
controllers
AC500 CPU
Fuse holders
E 90 PV
Miniature circuit
breakers
S800 PV-S
Residual current
devices
F200 PV-B
Surge protective
devices
OVR PV
Junction box