Você está na página 1de 7

INDUSTRIAL LOAD MANAGEMENT

SYSTEM USING SCADA & PLC

FMD88-10 PLC

FDM88-10
FMD88-10
T100MD888
Ethernet port can connect to other devices or web servers
Faster CPU
16 multi-functions digital I/Os and 10 analog I/Os (12-bit)
low cost, small foot-print circuit board open board design
Ladder+BASIC programming software
Expansion upto 120 Digital I/O using EXP1616R or EXP4040
Analog I/O expansion using RS485 port
RS232 and RS485 port for MODBUS protocol

ENERGY ANALYZER

1. V/A : Selects & Scrolls Voltage parameters display and phase current parameters display.
2. P : Select & Scrolls phase & system Power parameters
3. E : Select & Scrolls through Energy parameters
4. Sys : Select & Scroll through System parameters

OPERATION MODE

RS 485 communication

Potential Transformer Primary


Value

Potential Transformer Secondary


Value

Communication module in PLC and


energy analyzer

Current Transformer Primary


Value

Maximum length of 1.2km

Maximum of 32 instruments can be


connected

The permissible address range is


between 1 and247 for 32 instruments

The maximum latency time is 200

Current Transformer Secondary


Value

MULTIFUNCTION METER supports


MODBUS (RS485) RTU protocol( 2-wire ) .

AUTO-TRANSFER SWITCH

PURPOSE
These are four main interrupts
for overview
Automatic Transfer switch is
Complete version of:
Open Transition switch
Closed Transition switch
Soft Transition Switch
Non mechanical Static transfer
switch

Switching via Intrupts


System Start up Interrupt.
Power down Interrupt.
Surges Interrupt(5 Seconds).
Tripping hold interrupt.

cooling down interrupt.


1. Startup transition Switching.
2. Close Transition Switching.
3. Static Transition Switching

Architectural Benefits
Micro-processor based design
Automatic engine starting and
stopping commands
Automatic load transfer
Configurable via front panel
Automatic shut down on fault
condition
Test on / off modes
LED mimic indication
Operate with cranking dropouts
2 configurable auxiliary outputs
3 configurable auxiliary inputs
3 phase true RMS mains
voltage measuring and
monitoring
Mains frequency measuring
and monitoring
Generator phase true RMS
voltage measuring and
monitoring
Generator frequency measuring
and monitoring

Digitally adjustable low&high


mains and generator voltage
limits
Digitally adjustable generator
start command timings
Digitally adjustable generator
overspeed /underspeed limits
Digitally adjustable mains
voltage overspeed/underspeed
limits
Digitally adjustable auxiliary
inputs specifications
Digitally adjustable auxiliary
outputs specifications
Digitally adjustable load
transfer timings
Failure control
Digitally adjustable warm
up/cooling timings
Digitally adjustable
measurement calibrations
Digital display
Low cost,small dimensions

That is why that system can be installed in any


industry by just adjusting it according to industry
power demands and architecture.