Air System Sizing Summary for Default System

Project Name: Proyecto de aire acondicionado


Prepared by: UNEXPO Barquisimeto

09/06/2015
07:28p.m.

Air System Information


Air System Name ................................ Default System
Equipment Class ............................................ CW AHU
Air System Type ................................................ SZCAV

Number of zones ............................................................. 1


Floor Area ............................................................... 2552.0 ft
Location ....................................... Maracaibo, Venezuela

Sizing Calculation Information


Calculation Months ..................................... Jan to Dec
Sizing Data .................................................. Calculated

Zone CFM Sizing ................. Sum of space airflow rates


Space CFM Sizing ............. Individual peak space loads

Central Cooling Coil Sizing Data


Total coil load .......................................................... 16.1
Total coil load ....................................................... 192.6
Sensible coil load ................................................. 113.4
Coil CFM at Jul 1600 ............................................. 4336
Max block CFM ..................................................... 4336
Sum of peak zone CFM ........................................ 4336
Sensible heat ratio ............................................... 0.589
ft/Ton ................................................................... 159.0
BTU/(hr-ft) ............................................................. 75.5
Water flow @ 10.0 F rise .................................... 38.54

Tons
MBH
MBH
CFM
CFM
CFM

gpm

Load occurs at ..................................................... Jul 1600


OA DB / WB ...................................................... 96.5 / 83.9
Entering DB / WB ............................................. 82.2 / 70.8
Leaving DB / WB .............................................. 58.0 / 57.1
Coil ADP ..................................................................... 55.3
Bypass Factor .......................................................... 0.100
Resulting RH ................................................................. 58
Design supply temp. ................................................... 58.0
Zone T-stat Check .................................................... 1 of 1
Max zone temperature deviation .................................. 0.0

F
F
F
F
%
F
OK
F

Supply Fan Sizing Data


Actual max CFM .................................................... 4336 CFM
Standard CFM ....................................................... 4333 CFM
Actual max CFM/ft ................................................ 1.70 CFM/ft

Outdoor Ventilation Air Data

Fan motor BHP ........................................................... 2.97 BHP


Fan motor kW ............................................................. 2.36 kW
Fan static .................................................................... 2.50 in wg
CFM/person .............................................................. 12.04 CFM/person

Design airflow CFM ................................................. 891 CFM


CFM/ft ................................................................... 0.35 CFM/ft

Hourly Analysis Program v4.91

Page 1 of 5

Zone Sizing Summary for Default System


Project Name: Proyecto de aire acondicionado
Prepared by: UNEXPO Barquisimeto

09/06/2015
07:28p.m.

Air System Information


Air System Name ................................ Default System
Equipment Class ............................................ CW AHU
Air System Type ................................................ SZCAV

Number of zones ............................................................. 1


Floor Area ............................................................... 2552.0 ft
Location ....................................... Maracaibo, Venezuela

Sizing Calculation Information


Calculation Months ..................................... Jan to Dec
Sizing Data .................................................. Calculated

Zone CFM Sizing ................. Sum of space airflow rates


Space CFM Sizing ............. Individual peak space loads

Zone Terminal Sizing Data

Zone Name
Zone 1

Design
Minimum
Supply
Supply
Airflow
Airflow
(CFM)
(CFM)
4336
4336

Zone
CFM/ft
1.70

Reheat
Zone
Zone
Reheat
Coil
Htg Unit
Htg Unit
Mixing
Coil
Water
Coil
Water
Box Fan
Load
gpm
Load
gpm
Airflow
(MBH)
@ 20.0 F
(MBH)
@ 20.0 F
(CFM)
0.0
0.00
0.0
0.00
0

Zone Peak Sensible Loads

Zone Name
Zone 1

Zone
Cooling
Time of
Sensible
Peak Sensible
(MBH)
Cooling Load
78.6
Jul 1700

Zone
Heating
Load
(MBH)
0.0

Zone
Floor
Area
(ft)
2552.0

Space Loads and Airflows

Zone Name /
Space Name
Zone 1
planta baja
mezzanina

Hourly Analysis Program v4.91

Cooling
Sensible
(MBH)

Mult.
1
1

43.8
35.7

Time of
Peak
Sensible
Load
Jul 1700
Jul 1800

Air
Flow
(CFM)
2389
1947

Heating
Load
(MBH)
0.0
0.0

Floor
Area
(ft)
1597.0
955.0

Space
CFM/ft
1.50
2.04

Page 2 of 5

Air System Design Load Summary for Default System


Project Name: Proyecto de aire acondicionado
Prepared by: UNEXPO Barquisimeto

ZONE LOADS
Window & Skylight Solar Loads
Wall Transmission
Roof Transmission
Window Transmission
Skylight Transmission
Door Loads
Floor Transmission
Partitions
Ceiling
Overhead Lighting
Task Lighting
Electric Equipment
People
Infiltration
Miscellaneous
Safety Factor
>> Total Zone Loads
Zone Conditioning
Plenum Wall Load
Plenum Roof Load
Plenum Lighting Load
Return Fan Load
Ventilation Load
Supply Fan Load
Space Fan Coil Fans
Duct Heat Gain / Loss
>> Total System Loads
Central Cooling Coil
>> Total Conditioning
Key:

Hourly Analysis Program v4.91

09/06/2015
07:28p.m.

DESIGN COOLING
DESIGN HEATING
COOLING DATA AT Jul 1600
HEATING DATA AT DES HTG
COOLING OA DB / WB 96.5 F / 83.9 F
HEATING OA DB / WB 72.0 F / 60.1 F
Sensible
Latent
Sensible
Latent
Details
(BTU/hr)
(BTU/hr)
Details
(BTU/hr)
(BTU/hr)
0 ft
0
0 ft
1958 ft
22550
1958 ft
0
955 ft
11737
955 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
0 ft
0
1597 ft
0
1597 ft
0
411 ft
0
411 ft
0
1597 ft
0
1597 ft
0
5104 W
14632
0
0
0W
0
0
0
3506 W
11380
0
0
74
14974
32670
0
0
0
0
0
0
0
0
0
0
0
0% / 0%
0
0
0%
0
0
75274
32670
0
0
86044
32670
0
0
0%
0
0
0
0%
0
0
0
0%
0
0
0
4336 CFM
0
4336 CFM
0
891 CFM
19337
46531
891 CFM
-1924
0
4336 CFM
8036
4336 CFM
-8036
0
0
0%
0
0%
0
113417
79201
-9960
0
113417
79204
-9960
0
113417
79204
-9960
0
Positive values are clg loads
Positive values are htg loads
Negative values are htg loads
Negative values are clg loads

Page 3 of 5

System Psychrometrics for Default System


Project Name: Proyecto de aire acondicionado
Prepared by: UNEXPO Barquisimeto

09/06/2015
07:28p.m.

July DESIGN COOLING DAY, 1600


TABLE 1:

SYSTEM DATA

Component
Ventilation Air
Vent - Return Mixing
Supply Fan
Central Cooling Coil
Cold Supply Duct
Zone Air
Return Plenum

Location
Inlet
Outlet
Outlet
Outlet
Outlet
Outlet

Dry-Bulb
Temp
(F)
96.5
80.5
82.2
58.0
58.0
76.4
76.4

Specific
Humidity
(lb/lb)
0.02232
0.01358
0.01358
0.00973
0.00973
0.01132
0.01132

Airflow
(CFM)
891
4336
4336
4336
4336
4336
4336

CO2 Level
(ppm)
400
1655
1655
1655
1655
1980
1980

Sensible
Heat
(BTU/hr)
19337
8036
113417
86044
0

Latent
Heat
(BTU/hr)
46531
79204
32670
-

Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 1.079 BTU/(hr-CFM-F)
Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4743.2 BTU/(hr-CFM)
Site Altitude = 20.0 ft

TABLE 2:

ZONE DATA

Zone Name
Zone 1

Hourly Analysis Program v4.91

Zone
Sensible
Load
(BTU/hr)
75274

Zone
T-stat
Cond
Mode (BTU/hr)
Cooling
86044

Zone
Temp
(F)
76.4

Zone
Airflow
(CFM)
4336

CO2
Level
(ppm)
1980

Terminal
Heating
Coil
(BTU/hr)
0

Zone
Heating
Unit
(BTU/hr)
0

Page 4 of 5

System Psychrometrics for Default System


Project Name: Proyecto de aire acondicionado
Prepared by: UNEXPO Barquisimeto

09/06/2015
07:28p.m.

WINTER DESIGN HEATING


TABLE 1:

SYSTEM DATA

Component
Ventilation Air
Vent - Return Mixing
Supply Fan
Central Cooling Coil
Cold Supply Duct
Zone Air
Return Plenum

Location
Inlet
Outlet
Outlet
Outlet
Outlet
Outlet

Dry-Bulb
Temp
(F)
72.0
70.4
72.1
70.0
70.0
70.0
70.0

Specific
Humidity
(lb/lb)
0.00835
0.00835
0.00835
0.00835
0.00835
0.00835
0.00835

Airflow
(CFM)
891
4336
4336
4336
4336
4336
4336

CO2 Level
(ppm)
400
432
432
432
432
440
440

Sensible
Heat
(BTU/hr)
1924
8036
9960
0
0

Latent
Heat
(BTU/hr)
0
0
0
-

Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 1.079 BTU/(hr-CFM-F)
Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4743.2 BTU/(hr-CFM)
Site Altitude = 20.0 ft

TABLE 2:

ZONE DATA

Zone Name
Zone 1

Hourly Analysis Program v4.91

Zone
Sensible
Load
(BTU/hr)
0

Zone
T-stat
Cond
Mode (BTU/hr)
Deadband
0

Zone
Temp
(F)
70.0

Zone
Airflow
(CFM)
4336

CO2
Level
(ppm)
440

Terminal
Heating
Coil
(BTU/hr)
0

Zone
Heating
Unit
(BTU/hr)
0

Page 5 of 5