PCVAU1410

DAIKIN
GAS
HEAT PUMP
AIR CONDITIONING SYSTEM

Heat Pump / Heat Recover y 50 Hz

Air Conditioned Comfort, Powered by Natural Gas.


Benefits of Gas Heat Pump (GHP)

Daikin's Gas Heat Pump (GHP) air conditioning system is designed to


operate primarily on natural gas. GHP systems consume less electrical
power than conventional Electrical Heat Pump systems, whilst
delivering air conditioned comfort to the modern building.

Lower CO 2 Emission
Natural gas is used as the main energy
source. Natural gas emissions are
comparatively lower than other fossil fuels.

CO2 emissions

This unique gas powered air conditioning system is available both as a


Heat Pump and Heat Recovery system to suit a broad range of
applications, and when combined with an Electrical Heat Pump system
can provide an enhanced value proposition.

100

80

Coal

60
Natural gas

Petroleum

Reduced Power Consumption

What is GHP ?
The compressor is the heart of an
air conditioner and consumes
the most energy. In a Gas Heat Pump (GHP)
air conditioner, the compressor is
driven by a gas engine using natural gas,
whereas an Electric Heat Pump (EHP)
uses an electric motor.

Indoor Unit
Image of
heating

In GHP system, only the condenser


fans and the indoor units consume
electricity. In comparison to EHP, the
electrical power required to operate
GHP is significantly less, thereby
enabling the electrical substation and
switch gear equipment to be
downsized compared to EHP.

Power consumption

100

Fans

10

Heat
exchanger

E HP

Compressor

* CO2 emissions from coal = 100.


* Source: Natural Gas Prospects 2010, 1986/
EA Report on Thermal Power Plant Atmospheric
Impact Assessment Technology Demonstration
Surveys, March 1990/Institute of Applied Energy

GHP

* Power consumption of the EHP = 100.

Gas
Electricity

As the load changes during the day, GHP systems are able to match the varying load
by adjusting compressor capacity output through engine speed control.

GHP
EHP

Time

Heating capacity

How is capacity controlled?

01

Rapid and Powerful Heating

Outdoor Unit
Room temperature

Gas engine

-10C Outdoor temperature

GHP
EHP

10C

The ability to harness the waste heat


from the coolant circuit enables rapid
and powerful heating performance.
This feature also results in less
frequent defrost operation for GHP
systems.

Comparison of heating start speed and heating capacity (image)

02

3 Types available to various application


Daikin offers a range of Heat Pump and Heat Recovery systems
that are ideally suited for wide range of applications.

Heat Pump Standard Series

Footprint 1.46 m2

16-25 class

Heat Pump Large-capacity Series

Centralised control

Compact and Light Weight

Footprint 1.23 m2

8-13 class

Outdoor Unit Lineup


Heat Pump Large-capacity Series

By controlling both EHP and GHP systems off a common centralised control system,
the designer can capitalize on the unique characteristic and features of both
systems to deliver an engineered solution that meets the demands of the modern building.

Weight : 565 kg
13 class series

Control is centralised
by one controller.
D

Weight : 745 kg

-NET communication

20 class series

Space Saving Design

Both systems can be


controlled by the
centralised controller,
which makes it simple to
operate.

-NET communication

VRV System

GHP System

Outdoor Unit Lineup


Heat Pump Standard Series

Combine with VRV system

Outdoor Unit Lineup


Heat Recovery Series

Outdoor Unit Lineup

SYSTEM
(Electric Heat Pump)

Space Saving Design


Simultaneous Heating and Cooling Operation

Footprint 1.35 m2

20 class

Indoor units with constant


comfort and unified design
Since both systems are
connected to the same indoor
units, both the comfort level
and operation procedures are
the same. The designs of
front panels, etc. can also be
consistent.

Footprint 1.68 m2

30 class

For Replacement Use

Water Cooled Model

For Small-sized Building

Control Systems

Heat Recovery Series

Indoor Unit Lineup

Footprint 1.68 m2

30 class

Capacity range
Heat pump
standard series
Heat pump
large-capacity series
Heat recovery series

03

22.4 kW

28.0 kW

35.5 kW

45.0 kW

56.0 kW

71.0 kW

85.0 kW

8 class

10 class

13 class

16 class

20 class

25 class

30 class
Common models of indoor units

Common models of indoor units

Common indoor models for both GHP and EHP systems ensure
a consistent look for exposed units whilst maintaining similar
comfort levels and keeping operational control.

Air Treatment
Equipment Lineup

DAIKIN GAS HEAT PUMP AIR CONDITIONING SYSTEM LINEUP

04

Outdoor Unit Lineup


Heat Pump Standard Series

Outdoor Unit Lineup


Heat Pump Standard Series 8/10/13/16/20/25 class
Compact Design

Installation Flexibility

Compact, lightweight outdoor units increase installation flexibility.

Long piping length

8 / 10 / 13
class series

The long piping length provides more design flexibility, to meet the needs of large commercial buildings.

16 / 20 / 25
class series
Weight :

565 kg

2,077
mm

Max. actual
piping length

20 class series

165 m

745 kg

2,077
mm

13 class series

Weight :

880 mm

880 mm

Max. equivalent
piping length

190 m

*1

Max. total piping length

520 m

1,400 mm

1,660 mm

First indoor branch

Max. level difference

Footprint 1.23 m

h
e

between the outdoor units and


the indoor units

Footprint 1.46 m

Outdoor unit above indoor unit:

Compact size allows the outdoor unit


to be transported in an elevator.

The compact outdoor unit can be installed on


the service balcony of each floor.

(Unit: mm)

External static
pressure:

30 Pa

50 m
Outdoor unit below indoor unit:

40 m

Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .

Actual
piping length

Example

Equivalent
piping length

Refrigerant piping length

165 m

a+f+g+h+i

190 m *1

Total piping length

520 m

a+b+c+d+e+f+g+h+i

Between the first indoor branch and the farthest indoor unit

60 m

f+g+h+i

Level
Difference

Example

15 m

If the outdoor unit is above.

50 m

If the outdoor unit is below.

40 m

*1

Elevator

Outdoor unit

Outdoor unit
8 / 10 / 13 class series

2,077
1,400

* Check the dimensions of


the elevator to be used.

* Allow the specified space for service.


A discharge duct may need to be
installed on the outdoor unit.

Maximum
allowable
piping length

Maintenance
space

Balcony
*1. Field setting is necessary.

880

Maximum
allowable
level difference

Wide Operating Range

Quiet Operation

System can operate under a wide range


of outdoor temperature.

Use of cutting edge technology delivers quiet


operations. Enabling the quiet mode further
lowers operating noise levels.

Heating
Cooling

10C
10C

18C (WB)
43C

dB(A) 60
55

54

52

56

57

45
40

Easy Maintenance

10 class

13 class

* The outdoor unit enters


power-saving operation in quiet
mode.

Frequent oil change is not required.


Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 30,000hrs of operation.
* Use the engine oil specified by Daikin.

05

Connection ratio
Maximum connection ratio is 130%.

Connection ratio

50%130%

Normal mode
Quiet mode

50

8 class

Between the outdoor units


and the indoor units

*1. When the equivalent piping length between outdoor and indoor units is 100 m or more, the size of main pipes (both gas-side and liquid-side) must be
increased.Refer to the Engineering Data Book.

59
54

Between the indoor units

Connection ratio =

Total capacity index of the indoor units


Capacity index of the outdoor units

Outdoor unit combination


Model name *1
GYAQ8ANV1
GYAQ10ANV1
GYAQ13ANV1
GYAQ16ANV1
GYAQ20ANV1
GYAQ25ANV1

kW
22.4
28.0
35.5
45.0
56.0
71.0

Class
8
10
13
16
20
25

Capacity
index
200
250
320
400
500
630

Total capacity index of connectable indoor units *2


Combination (%) *2
50%
100
125
160
200
250
315

100%
200
250
320
400
500
630

130%
260
325
416
520
650
819

Maximum number of
connectable indoor units
13
16
20
26
33
41

*1.Only single outdoor unit can be connected.


*2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit.

06

Outdoor Unit Lineup


Heat Pump Standard Series

Outdoor Unit Lineup


Heat Pump Standard Series 8/10/13/16/20/25 class
Operation range
INDOOR TEMPERATURE (CWB)

Cooling operation

Model

GYAQ8ANV1

GYAQ10ANV1

Power supply
Gas

GYAQ13ANV1

Capacity

22.4

28.0

35.5

45.0

56.0

71.0

76,400

95,500

121,000

154,000

191,000

242,000

kcal/h

19,300

24,100

30,500

38,700

48,200

61,100

25.0

31.5

40.0

50.0

63.0

80.0

Btu/h

85,300

107,000

136,000

171,000

215,000

273,000

kcal/h

21,500

27,100

34,400

43,000

54,200

68,800

kW
2

Ivory white (9.9Y8.4/1.2)


mm

2,077

2,077

2,077

2,077

2,077

2,077

mm

1,400

1,400

1,400

1,660

1,660

1,660

Depth

mm

880

880

880

880

880

880

Height

Cooling
Power
consumption
Heating

kW

0.34

0.44

0.57

1.26

1.26

1.53

kW

0.42

0.58

0.74

1.11

1.11

1.34

Cooling
Fuel gas
consumption Heating

kW

15.0

19.2

26.4

31.0

41.7

58.5

kW

15.9

20.3

27.0

32.7

42.0

57.2

Scrollx1

Scrollx1

Scrollx1

Scrollx2

Scrollx2

Scrollx2

Type
Type

Propeller fan

Number of units
Motor output

Airflow rate

m3/min

275x2

275x2

275x2

350+600

350+600

600x2

167

194

213

346

346

388

15.9

15.9

15.9

Drive
Refrigerant
Piping

Direct drive
Liquid

mm

Gas

9.5

9.5

mm

19.1

22.2

25.4

28.6

28.6

31.8

inch

R3/4

R3/4

R3/4

R3/4

R3/4

R3/4

Exhaust vent outside dia.

mm

80

80

80

100

100

100

Drain pipe for exhaust inside dia. mm

30

30

30

30

30

30

565

565

565

745

745

755

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

11.0

11.0

11.0

11.5

11.5

11.5

62

kg
Type
Charge

kg

Engine Lubricant Type


Engine
coolant

14
-10

43

-10

10
20
30
OUTDOOR TEMPERATURE (CDB)

40

OPERATION
10

10

-30

-10

-20

-10

18

10

20

OUTDOOR TEMPERATURE (CWB)

Options
Option name
Cool/Heat selector *1
Fixing box
Harness kit for Cool/Heat Selector *2
REFNET header

Model

GYAQ8ANV1

GYAQ10ANV1

GYAQ16ANV1

GYAQ20ANV1

GYAQ25ANV1

KRC19-26A
KJB111A
AGKRC19E1
KHRP26M22H (Max. 4 branch)
KHRP26M33H (Max. 8 branch)

KHRP26M22H (Max. 4 branch)


KHRP26M33H (Max. 8 branch)
KHRP26M72H (Max. 8 branch)

KHRP26A22T
KHRP26A33T

KHRP26A22T
KHRP26A33T
KHRP26A72T

Distributive
piping
REFNET joint

GYAQ13ANV1

KHRP26M22H
KHRP26M33H
KHRP26M72H
KHRP26M73H

4
8
8
8

branch)
branch)
branch)
branch)

KHRP26A22T
KHRP26A33T
KHRP26A72T
KHRP26A73T
KHRP26M73TP
KHRP26M73HP

Pipe size reducer


Antivibration mount *3
Air direction adjuster *4
Deodorizer kit

(Max.
(Max.
(Max.
(Max.

K-GBM13B70
AGFJ280E1
AGBJ280E1

K-GBM13B71
AGFJ560E2
AGBJ560E1

*1. The Cool/Heat Selector is required when selecting cool/heat mode from the outdoor unit.
*2. The harness kit is required when using the Cooling/Heating Selector.
*3. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.
The specified antivibration mount must be used. Otherwise abnormal vibration may occur.
*4. The Air direction adjuster is designed to prevent snow from accumulating on the air outlet of the outdoor unit and to change the air direction to the front or back if the air outlet is
blocked by an obstacle. If The Air direction adjuster is installed, the operation sound may increase slightly depending on ambient conditions.

Aisin Coolant S

Freezing temperature

-35

Normal mode
Sound
pressure level Quiet mode

dB(A)

54

56

59

56

59

dB(A)

52

54

57

54

57

60

Piping length;equivalent/actual

190/165

190/165

190/165

190/165

190/165

190/165

Height difference between O/U is above m


indoor and out door units O/U is below m

50

50

50

50

50

50

40

40

40

40

40

40

Height difference between indoor units m

15

15

15

15

15

15

13

16

20

26

33

41

50-130

50-130

50-130

50-130

50-130

50-130

Note:

10

RANGE FOR CONTINUOUS OPERATION

RANGE FOR CONTINUOUS

20

Aisin Gas Engine Oil L-10000G

Type

Connectable indoor units

07

12.7

Fuel gas pipe

Weight
Refrigerant

20

28

* If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit.

Dimensions Width

Fans

24

30

GYAQ25ANV1

Btu/h

Casing colour (Munsell no.)

Compressor

30

Natural gas
kW

Heating

GYAQ20ANV1

1- phase , 230 V , 50 Hz

Type
Cooling

GYAQ16ANV1

Heating operation
INDOOR TEMPERATURE (CDB)

Specifications

number
capacity

1 Indoor temp.: 27 CDB, 19CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m
2 Indoor temp.: 20 CDB / outdoor temp.: 7CDB, 6CWB/ Equivalent piping length: 7.5 m, level difference: 0 m

08

Outdoor Unit Lineup

Space Saving Design

Installation flexibility

Space saving design allows for


flexible installation.

Long piping length


Weight :

Outdoor Unit Lineup


Heat Pump Large-capacity Series

Heat Pump Large Capacity Series 30 class

The long piping length provides more design flexibility, which can match even large-sized buildings.

1080 kg
2,170
mm

Max. actual
piping length

Footprint 1.68 m2

800 mm

Max. equivalent
piping length

170 m

200 m

Max. total piping length

640 m

2,100 mm

The compact outdoor unit can be installed on the service balcony of each floor.
External static
pressure:

First indoor branch

Maintenance
space

*1. Field setting is necessary.

Wider Operating Range


System can operate under a wider
range of outdoor temperature.
Heating

21C

18C (WB)

Cooling

10C

46C

Quiet Operation

k
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .

dB(A) 65

60

Maximum
allowable
piping length

Maximum allowable
level difference

Use of cutting edge technology delivers


quiet operations. Enabling the quiet mode
further lowers operating noise levels.

50 m

Actual
piping length

Balcony

between the outdoor units and


the indoor units

*1

* Allow the specified space for service.


A discharge duct may need to be
installed on the outdoor unit.

Max. level difference

30 Pa

Outdoor unit

Example

Equivalent
piping length

Refrigerant piping length

170 m

a+f+g+h+i

200 m

Total piping length

640 m

a+b+c+d+e+f+g+h+i

Between the first indoor branch and the farthest indoor unit

90 m *1

f+g+h+i

Level
Difference

Example

Between the indoor units

15 m *1

Between the outdoor units and the indoor units

50 m

*1.When the piping length between the indoor branch and the farthest indoor unit is 40 m or more, the maximum allowable level difference between the indoor
units is decreased.Refer to the Engineering Data Book.

62
59

55

Normal mode

Connection ratio

Quiet mode

Maximum connection ratio is 130%.

Connection ratio

50%130%

50

45

30 class

* The outdoor unit enters power-saving


operation in quiet mode.

Easy Maintenance
Frequent oil change is not required.
Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 20,000hrs of operation.

Connection ratio =

Total capacity index of the indoor units


Capacity index of the outdoor units

Outdoor unit combination


Model name *1
GYAQ30ANV1

kW
85.0

Class
30

Capacity
index
750

Total capacity index of connectable indoor units *2


Combination (%) *2
50%
375

100%
750

130%
975

Maximum number of
connectable indoor units
48

*1.Only single outdoor unit can be connected.


*2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit.

* Use the engine oil specified by Daikin.

09

10

Outdoor Unit Lineup


Heat Pump Large Capacity Series 30 class
Specifications

Operation range

GYAQ30ANV1

Power supply
Gas

1- phase , 230 V , 50 Hz

Type
1

Capacity

290,000

kcal/h

73,100

Btu/h

kcal/h
Casing colour (Munsell no.)

95.0
324,000
81,700
Ivory white(5Y7.5/1)

mm

2,170

Dimensions Width

mm

2,100

Depth

mm

800

Cooling
Power
consumption Heating

kW

1.66

kW

1.51

Cooling
Fuel gas
consumption Heating

kW

67.7

Height

Compressor

kW

66.3

Type

Scrollx2

Type

Propeller fan

Number of units
Fans

Motor output

Airflow rate

m3/min

Drive

570
Direct drive

mm

Gas

mm

31.8

Fuel gas pipe

inch

R3/4

Exhaust vent outside dia.

mm

60.5

Drain pipe for exhaust inside dia. mm


Weight
Refrigerant

370x3

Liquid

Refrigerant
Piping

20

10

(Note 1)

RANGE FOR CONTINUOUS OPERATION

14
-10

-10

46

10
20
30
OUTDOOR TEMPERATURE (CDB)

40

50

30
RANGE FOR CONTINUOUS OPERATION

20
15

-21

18

10

-30

-20

-10

10

20

OUTDOOR TEMPERATURE (CWB)

Note 1: An optional air guard is required.


* If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit.

85.0

Btu/h
kW

Heating

25

30

Natural gas
kW

Cooling

30

Outdoor Unit Lineup


Heat Pump Large-capacity Series

Model

Heating operation
INDOOR TEMPERATURE (CDB)

INDOOR TEMPERATURE (CWB)

Cooling operation

kg
Type

19.1

Option name
Cool/Heat selector
Fixing box
REFNET header
Distributive
piping
REFNET joint
Pipe size reducer
Antivibration mount *1
Air direction adjuster
Air guard
Exhaust extension adaptor
Exhaust extension external drain filter
Water discharge kit
External contact output harness *2

Model

GYAQ30ANV1
KRC19-26A
KJB111A
KHRP26M22H
KHRP26M33H
KHRP26M72H
KHRP26M73H

(Max.
(Max.
(Max.
(Max.

4
8
8
8

branch)
branch)
branch)
branch)

KHRP26A22T
KHRP26A33T
KHRP26A72T
KHRP26A73T
KHRP26M73TP , KHRP26M73HP
YGAS850J1
FKA850H
ARD850H
HA850H
DFB19E
RGA850H1
OSH850J

*1. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.
The specified antivibration mount must be used. Otherwise abnormal vibration may occur.
*2. Only use of input contact point is possible. Use of output contact point is not possible. (only for 30 class heat pump)

15
1080
R-410A

Charge

kg

Engine Lubricant Type

11.8
Yanmar genuine GHP oil

Engine
coolant

Type

Sound
pressure level

Normal mode

dB(A)

Quiet mode

dB(A)

Yanmar genuine LLC (for GHP)

Freezing temperature

Piping length;equivalent/actual

-35

62
59
200/170

Height difference between O/U is above m


indoor and out door units O/U is below m

50

Height difference between indoor units m

15

Connectable indoor units

Options

number
capacity

50
48

50-130

Note:
1 Indoor temp.: 27 CDB, 19 CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m
2 Indoor temp.: 20 CDB / outdoor temp.: 7CDB, 6CWB/ Equivalent piping length: 7.5 m, level difference: 0 m

11

12

Outdoor Unit Lineup


Heat Recovery Series 20/30 class
Heat Recovery Operation

Large Capacity & Space Saving Design

Simultaneous heating and cooling operation within refrigerant system

Space saving outdoor units allow flexible installation.

BS unit
Indoor unit
(Heating)

800 mm

Indoor unit
(Cooling)

1,690 mm

Heat radiation operation


(all cooling operation)

BS
Unit

Heat radiation
cooling

cooling
cooling
Indoor Unit

For example,
the heat recovery system can
meet the following needs:

2,100 mm

Footprint 1.35 m2

Heat recovery operation mode

Outdoor Unit

1040 kg

2,170
mm

800 mm

Heat recovery operation!

(A)

Weight :

860 kg

2,170
mm

By adding suction gas piping and a BS


unit (sold separately), simultaneous
heating and cooling operation can be
provided by a single system.

BS unit

30 class
series
Weight :

BS unit

High and low pressure gas piping


Suction gas piping
Liquid piping
Outdoor unit

20 class
series

Footprint 1.68 m2

The compact outdoor unit can be installed on the balcony of each floor.

cooling

External static
pressure:

Heat radiation tendency


heat recovery operation

(B)

cooling,
( mainly
part heating operation )

Heat radiation

Outdoor Unit Lineup


Heat Recovery Series

In mainly cooling, partly heating mode, the system recycles heat exhausted from the cooling operation to use for heating.
In mainly heating, partly cooling mode, the system uses cooled post-heating operation refrigerant for cooling. Efficiency
improves when simultaneous operation is performed.

Heating
Window
cooling

cooling

cooling

Cooling

Cooling

BS unit

*1

* Allow the specified space for service.


A discharge duct may need to be
installed on the outdoor unit.

heating

Heat recovery operation

30 Pa

Outdoor unit

Office building in transition period to winter

(cooling and heating operation)

The difference between heat generated from the interior zone


and the cool air load in the perimeter zone is large.

(C)

Maintenance
space

Balcony
*1. Field setting is necessary.

cooling

cooling

heating

heating

Heat absorption tendency


heat recovery operation

(D)

Heat absorption

Cooling

Heating

heating,
( mainly
part cooling operation )

BS unit
cooling

heating

heating

Hallway

heating

Wide Operating Range

Quiet Operation

System can operate under a wide


range of outdoor temperature.

Use of cutting edge technology delivers


quiet operations. Enabling the quiet mode
further lowers operating noise levels.

Hotel in transition period

Heat absorption operation

Indoor units can independently meet the need for cooling


and heating.

(all heating operation)

(E)
heating

heating

heating

heating

Heating

11C

18C (WB)

Cooling

10C

43C

Note: Operation modes (A) and (E) are applicable when the outdoor temperature is 35C and 7C respectively;
The other modes are applicable under typical outdoor conditions.

dB(A) 65

60
55

62

58

59
55

Normal mode
Quiet mode

50

Thanks to the heat recovery system.

13

* The outdoor unit enters power-saving


operation in silent mode.

45

20 class

Automatic cooling-heating switching

Heat recovery saves energy

The system automatically switches the


operation mode to cooling or heating based on
the difference between the set temperature and
the indoor temperature. It is not necessary to
use the remote controller to switch the
operation mode to cooling or heating.

Operation efficiency can be


further increased by
recovering cooling exhaust
heat within the same system
and using it effectively as
heating energy.

30 class

Easy Maintenance
Heating

Cooling

Cooling exhaust heat is


recovered
as heating energy.

Frequent oil change is not required.


Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 20,000hrs of operation.
* Use the engine oil specified by Daikin.

14

Outdoor Unit Lineup


Heat Recovery Series 20/30 class
Installation Flexibility

Specifications

Long piping length


The long piping length provides more design flexibility, which can match even large-sized buildings.
Max. actual
piping length

Max. equivalent
piping length

170 m

200 m

640 m
First indoor branch

Max. level difference

between the outdoor units and the indoor units

f
b

Model

h
d

GYEQ20AN

Power supply

Gas

Natural gas

Type
kW
Cooling

Capacity

50 m

56.0

85.0

Btu/h

191,000

290,000

kcal/h

48,200

73,100

kW
Heating

63.0

95.0

Btu/h

215,000

324,000

kcal/h

54,200

Casing colour (Munsell no.)

Maximum
allowable
piping length

Actual
piping length

Example

Refrigerant piping length

170 m

a+f+g+h+i

200 m

Total piping length

640 m

a+b+c+d+e+f+g+h+i

f+g+h+i

Between the first indoor branch and the farthest indoor unit

90 m*

Equivalent
piping length

mm

2,170

2,170

mm

1,690

2,100

Depth

mm

800

800

Cooling
Power
consumption
Heating

kW

1.17

1.77

kW

1.10

1.57

Cooling
Fuel gas
consumption Heating

kW

47.4

67.7

kW

46.6

66.3

Scrollx2

Scrollx2

Compressor

Type
Type

Propeller fan

Number of units

Maximum allowable
level difference

Level
Difference

Example

Between the indoor units

15 m*1

Between the outdoor units and the indoor units

50 m

Fans

50%130%

Connection ratio =

Total capacity index of the indoor units


Capacity index of the outdoor units

20
30

Capacity
index
500
750

Total capacity index of connectable indoor units *2


Combination (%) *2
50%
250
375

*1.Only single outdoor unit can be connected.


*2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit.

100%
500
750

130%
650
975

Maximum number of
connectable indoor units
32
48

570

15.9

19.1

28.6

31.8

mm

22.2

28.6

Fuel gas pipe

inch

R3/4

R3/4

Exhaust vent outside dia.

mm

60.5

60.5

kg

Refrigerant

Type
Charge

kg

15

15

860

1040

R-410A

R-410A

11.8

Engine Lubricant Type

11.8
Yanmar genuine GHP oil

Type

Yanmar genuine LLC (for GHP)

Freezing temperature

-35

Sound
pressure level Quiet mode

dB(A)

58

dB(A)

55

59

Piping length;equivalent/actual

200/170

200/170

Height difference between O/U is above m


indoor and out door units O/U is below m

50

50

50

50

Height difference between indoor units m

15

15

Connectable indoor units

Note:

15

380

mm

Normal mode

outdoor unit combination


Class

370x3

mm

Weight

Connection ratio

370x2
Direct drive

Discharge

Engine
coolant

56.0
85.0

m3/min

Drain pipe for exhaust inside dia. mm

Maximum connection ratio is 130%.

GYEQ20AN
GYEQ30AN

Airflow rate

Refrigerant Suction
Piping

kW

Liquid

1. When the piping length between the indoor branch and the farthest indoor unit is 40 m or more, the maximum allowable level difference between the indoor units is
decreased.Refer to the Engineering Data Book.

Model name *1

Motor output

Drive

Connection ratio

81,700
Ivory white(5Y7.5/1)

Dimensions Width

Height
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .

GYEQ30AN
1- phase , 200 V , 50 Hz

Outdoor Unit Lineup


Heat Recovery Series

Max. total piping length

number
capacity

62

32

48

50-130

50-130

1 Indoor temp.: 27 CDB, 19 CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m
2 Indoor temp.: 20 CDB / outdoor temp.: 7 CDB, 6 CWB/ Equivalent piping length: 7.5 m, level difference: 0 m

16

Outdoor Unit Lineup


Heat Recovery Series 20/30 class
BS Unit: Specifications

Operation range
Heating operation

25
20

10

(Note 1)

RANGE FOR CONTINUOUS OPERATION

14
-10

-10

43

10
20
30
OUTDOOR TEMPERATURE (CDB)

40

30

30
RANGE FOR CONTINUOUS
OPERATION

20
15

18

-11

10

-30

-20

-10

10

20

OUTDOOR TEMPERATURE (CWB)

Note 1: An optional air guard is required.


* If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit.

MODEL

BSGQ100PV1

Power supply
Total capacity index of connectable indoor units
No. of connectable indoor units

Model

GYEQ20AN

GYEQ30AN
KRC19-26A
KJB111A

REFNET header

KHRP25M33H (Max. 8 branch)


KHRP25M72H (Max. 8 branch)
KHRP25M73H (Max. 8 branch)

REFNET joint

KHRP25A22T,KHRP25A33T
(KHRP25A72T+KHRP25M72TP)
(KHRP25A73T+KHRP25M73TP)

Distributive
piping

Antivibration mount *1
Air direction adjuster
Air guard
Exhaust extension adaptor
Exhaust extension external drain filter
Water discharge kit
External contact output harness

20 to 100

More than 100 but 160 or less

More than 160 but 250 or less

Max. 5

Max. 8

Max. 8

Casing

Galvanised steel plate

Dimensions (HXWXD)
Option name
Cool/Heat selector
Fixing box

YGAS560J1
FKA560H
ARD560H

Piping
connections

Indoor Liquid
Unit
Gas

YGAS850J1
FKA850H
ARD850H

Notes:

mm
mm

Liquid
Outdoor
mm
Suction gas
Unit
High and low pressure gas

Machine weight
Sound level

BSGQ250PV1

No. of branches

Outdoor Unit: Options

BSGQ160PV1
1-phase, 220-240 V, 50 Hz

207x388x 326
9.5 (Brazing) 1

9.5 (Brazing)

9.5 (Brazing)

15.9 (Brazing) 1

15.9 (Brazing) 2

22.2 (Brazing) 3

9.5 (Brazing)

9.5 (Brazing)

9.5 (Brazing)

15.9 (Brazing)

15.9 (Brazing) 2

22.2 (Brazing) 3

12.7 (Brazing)

12.7 (Brazing) 2

kg

12.0

12.0

dB(A)

42 (32) 4

43 (32) 4

Outdoor Unit Lineup


Heat Recovery Series

30

INDOOR TEMPERATURE (CDB)

INDOOR TEMPERATURE (CWB)

Cooling operation

19.1 (Brazing) 3
15.0
44 (34) 4

1 When connecting with an indoor unit with a capacity index between 20 and 50, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.)
2 When connecting with indoor units with total capacity indexes between 150 and 160, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.)
3 When connecting with indoor units with a capacity index of 200, or with total capacity indexes between 160 and 200, connect the attached pipe to the field pipe.
(Braze the connection between the attached and field pipe.)
4 Figures in brackets ( ) indicate sound levels when the all indoor units connected to the BS unit are not operating but other indoor units within the same system are operating.

HA850H
DFB19E
RGA850H1
OSH850J

*1. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.
The specified antivibration mount must be used. Otherwise abnormal vibration may occur.

17

18

Indoor Unit Lineup


Daikins indoor units are available in 90 models of 16 types to deliver comfortable
air conditioning whilst matching the varied requirements of the modern office and
residential building.

Ceiling Suspended Type

Wall Mounted Type

Slim body with quiet and wide


airflow

Stylish flat panel design


harmonised with your interior
dcor

Lineup
FXFQ-SVM

Ceiling Mounted Cassette


(Round Flow) Type
FXFQ-PVE

To be launched
in June 2014

Presence of people and floor


temperature can be detected to
provide comfort and energy savings

Ceiling Mounted Cassette


(Compact Multi Flow) Type

Quiet, compact, and designed for


user comfort

Floor Standing Type


360 airflow improves temperature
distribution and offers a
comfortable living environment.

4-Way Flow Ceiling


Suspended Type

This slim and stylish indoor unit


achieves optimum air distribution,
and can be installed without the
need for ceiling cavity.

Concealed Floor Standing Type


Suitable for perimeter zone air
conditioning

Indoor units
(kW)

2.2

2.8

3.6

4.5

FXFQ-SVM

To be launched
in June 2014

Ceiling Mounted Cassette


(Double Flow) Type

Thin, lightweight, and easy to install in


narrow ceiling spaces

Slim Ceiling Mounted Duct Type


FXDQ-PBVE

FXFQ-PVE

Ceiling Mounted Cassette


Corner Type

11.2

14

16

145
16.2
145

180
20
180

22.4

28

Ceiling Mounted Built-in Type


FXSYQ-MVE

FXDQ-NBVE

Ceiling Concealed
(Duct) Type

7.1

Slim design for flexible installation

Ceiling Mounted
Built-in

Slim design, quietness and


static pressure switching

5.6

Indoor Unit Lineup

Ceiling Mounted Cassette


(Round Flow with Sensing) Type

Ceiling Concealed
(Duct)

FXSYQ-MVE
FXDYQ-M(A)V1

Highly flexible for various


application

Ceiling Mounted Duct Type

FXDYQ-M(A)V1

High static pressure offers flexible


duct design that blends in with any
interior dcor in stores and offices

19

High external static pressure


allows flexible installations

This FXUQ model is not compatible both Heat Pump 30 class and Heat Recovery systems.

20

Indoor Unit Lineup


Ceiling Mounted Cassette (Round Flow with Sensing) Type

Airflow block function *3

Auto airflow rate mode + Auto airflow direction mode

FXFQ25S/FXFQ32S/FXFQ40S

Floor temperature is detected and over cooling prevented.

FXFQ50S/FXFQ63S/FXFQ80S

Without sensing function

FXFQ100S/FXFQ125S

To be launched
in June 2014

With sensing function

Room temperature is
calculated as 27C in the area which
is in the vicinity of the person.

Infrared presence sensor

24C near floor

The floor temperature, which is lower


than near the ceiling, is detected.

Energy savings
The temperature near the person is automatically calculated by
detecting the temperature of the floor. Energy is saved, because
the area around the feet does not get too cold.

Indoor unit offers 360 airflow discharges air in all


directions with more uniform temperature distribution.

Sensing sensor mode

Infrared floor sensor


The sensor detects the floor temperature and automatically
adjusts operation of the indoor unit to reduce the temperature
difference between the ceiling and the floor.

Individual airflow direction control


Thanks to the individual airflow direction control function, airflow
direction can be individually adjusted for each air discharge
outlet. 5 directions of airflow and auto-swing can be selected
with wired remote controller BRC1E62, which realises the
optimum air distribution.
Individual airflow direction example case

21

Position 2

Swing

Comfortable airflow
Airflow rate automatically increases during hot or cold periods (when there
is a large difference with set temperature), and operation is rapidly
performed for cooling or heating.When the difference with set temperature
becomes small, drafts are prevented by automatically reducing airflow rate,
and raising the flap to a horizontal position during cooling operation.

Dead spot of airflow

Energy efficiency has been improved thanks to the


adoption of a new heat exchanger with smaller tubes,
DC fan motor and DC drain pump motor.

Low operation sound level


FXFQ-S

Sound
level
(H/M/L)

25/32

40

50

63

80

100

125

30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35

Control of airflow rate can be selected from 3-step


control, which provides comfortable airflow. Auto airflow
rate control can be selected with wired remote controller
BRC1E62.
Drain pump is equipped as
standard accessory with 850 mm
lift.

Airflow block function prevents uncomfortable


drafts by reducing air velocity to approx. 0.3m/s.*4

Airflow block
for cabinet side

Also can support


such this case

New airflow block function prevents


uncomfortable drafts by reducing air velocity.
It can be set using the BRC1E62 remote controller.
There is no need for sealing material of air discharge
outlet (option).
This function only works when all-round flow
is used. It cannot be used when sealing material is
used in the air discharge outlet (option).
Easy setup with remote controller

Sensing sensor low mode *1. 2


When there are no people in a room,
the set temperature is shifted automatically.

850 mm

Example: Cooling setpoint: 26C


Shift temperature: 1.0C

Setpoint (C)

Detecting the
average
temperature of
indoor floor

Position 3

Automatic
control using
the temperature
near the person
as the room
temperature.

30C near ceiling

Dual sensors detect the presence of people and floor temperature


to provide comfortable air-conditioning and energy savings.

Position 0

Area around feet gets


too cold because air
conditioner continues
until the temperature
near the ceiling reaches
the set temperature.

Room
temperature is
detected as
30C.
20C near floor

Presence of
people in 4
areas

Airflow block
air velocity
approx. 0.3m/s*4

30C near ceiling

Presence of people and floor temperature can be


detected to provide comfort and energy savings

The sensor detects human presence and adjusts


the airflow direction automatically to prevent drafts.
Energy saving control can be performed
when no people are detected.

Total comfort by individual airflow direction control


and newly-equipped airflow block function

Indoor Unit Lineup

Sensing function

28
27
26

27C

26C
Occupied

Shift time: 30 min.


Limit cooling temperature: 30C
28C

Unoccupied

After 30 min

After another 30 min

26C

Automatically
reverts when
people return.

Horizontal flow

The airflow block function is


useful when rearranging the
room layout.

Time

If people do not return, the air conditioner will raise the


temperature 1C every 30 minutes and then operate at 30C.

Shift temperature and time can be selected from 0.5 to 4C in 0.5C increments
and 15, 30, 45, 60, 90 or 120 minutes respectively with remote controller.

Airflow block

Airflow
block

500 mm*5
Wall

*3. Works in one direction only.

*4. In case of FXFQ63S type (Data is based on Daikin research.)


*5. A gap of 1500 mm is required if the air block function is not used.

Sensing sensor stop mode *1. 2


When there are no people in a room, the system
stops automatically.

Absent stop time can be selected from 1 to 24 hrs in 1 hr


increments with remote controller.

*1. These functions are not available when using the group control system.
*2. User can set these functions with remote controller.

22

Indoor Unit
UnitsLineup
Ceiling Mounted Cassette (Compact Multi Flow) Type

Ceiling Mounted Cassette (Round Flow) Type

FXFQ25P/FXFQ32P/FXFQ40P

FXZQ20M / FXZQ25M / FXZQ32M

FXFQ50P/FXFQ63P/FXFQ80P

FXZQ40M / FXZQ50M

FXFQ100P/FXFQ125P

360 airflow improves temperature distribution


and offers a comfortable living environment.
The industrys first* Round Flow Ceiling Mounted
Cassette type offers 360 airflow with improved
temperature distribution.
4-way flow

Quiet, compact, and designed for user comfort


Dimensions correspond with 600 mm X 600 mm
architectural module ceiling design specifications.
Low operation sound level

Round Flow

(240 V)(dB(A))

FXZQ-M

20/25

32

40

50

Sound level
(H/L)

32/26

34/28

37/29

42/35

Comfortable airflow
1

There are much fewer


areas of uneven temperature.

Wide discharge angle: 0 to 60

Indoor Unit Lineup

There are areas of


uneven temperature.

Auto swing

* As of April 2004, the release date for Japan.

The light weight unit at 19.5 kg for FXFQ25-50P


models makes installation easy.
Drain pump is equipped as a
standard accessory with a 850 mm
lift.

A modern sophisticated decoration panel has been


applied, with a panel surface that has been treated with
a dirt-repellant coating.
Treated surface

Untreated surface
Dirt and
grime Condition after
exposure to the
smoke of 600
3
cigarettes in 1 m
enclosed space.

Resists
soiling

Control of the airflow rate can be selected from 3-step


control.
Low operation sound level
FXFQ-P

25/32

40

50

(dB(A))
63

80

100

125

Sound
level
30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34
(HH/H/L)

Example of airflow patterns:

850 mm

All-round flow

60

60

Fixed angles: 5 levels

An antibacterial treatment that uses silver ions has


been applied to the drain pan, preventing the growth
of slime, mould and bacteria that cause blockages
and odours.
The horizontal louvres prevent dew condensation.
Their non-flocking surfaces, which repel dirt, are
easy to clean.
The air filter has an anti-mould and antibacterial
treatment that prevents the growth of mould
generated from dust or moisture that may adhere to
the filter.
4-way flow

3-way flow

0
60

Drain pump is equipped as standard accessory with


750 mm lift.

60

*Angles can be also set on site to prevent drafts (0-35)


or soiling of the ceiling (25-60), other than standard setting (0-60).

2-, 3-, and 4-way airflow patterns are available,


enabling installation in the corner of a room.

750 mm

L-shaped 2-way flow

All-round flow is available, as well as 2-way to


4-way flows, so you can choose the most
suitable airflow pattern depending on location or
room layout.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.

23

4-way flow

3-way flow

L-shaped
2-way flow

*For 3-way or 2-way flow installation, the sealing member for air discharge outlet
(option) must be used to close each unused outlet.

24

Indoor Unit
UnitsLineup
Ceiling Mounted Cassette (Double Flow) Type

4-Way Flow Ceiling Suspended Type

FXCQ20M/FXCQ25M/FXCQ32M
FXCQ40M/FXCQ50M/FXCQ63M

FXUQ71A/FXUQ100A

FXCQ80M/FXCQ125M

This model is not compatible both Heat Pump 30 class and Heat
Recovery systems.

This slim and stylish indoor unit achieves


optimum air distribution, and can be installed
without the need for ceiling cavity.
Unit body and suction
panel adopted round
shapes and realised a
slim appearance design.
The unit can be used for
various locations such as
the ceilings with no cavity
and bare ceilings.

Thin, lightweight, and easy to install in


narrow ceiling spaces
The thin unit (only 305 mm high) can be installed in a
ceiling space as narrow as 350 mm. All models feature a
compact design with a depth of only 600 mm.

Indoor Unit Lineup

305 mm

(When a high-efficiency filter is attached, the unit's height is


400 mm.)

Flaps close automatically when the unit stops, which gives


a simple appearance.
Unified slim height of 198 mm
for all models that gives the
unified impression even when
models with different
capacities are installed in the
same area.

198 mm

With adoption of the individual flap control, airflow


direction adjustment can be individually set for each air
outlet. 5 directions of airflow and auto-swing can be
selected with wired remote controller BRC1E62, which
realises the optimum air distribution.

Low operation sound level

Control of the airflow rate has been improved from


2-step to 3-step control. Auto airflow rate control can
be selected with wired remote controller BRC1E62.
Energy efficiency has been improved thanks to the
adoption of a new heat exchanger with smaller
tubes, DC fan motor and DC drain pump motor.
Drain pump is equipped as a standard accessory, and the
lift height has been improved from 500 mm to 600 mm.
Depending on installation site requirements or room
conditions, 2-way, 3-way and 4-way discharge
patterns are available.
4-way flow

3-way flow

(240 V)(dB(A))

FXCQ-M

20

25/32

40/50

63

80

125

Sound level
(H/L)

34/29

36/30

37/32

39/34

41/36

46/40

Designed with higher airflow suitable for high ceiling


application up to 3 metres.
Providing 2 different settings of standard and ceiling soiling
prevention, the auto swing mechanism realises even
distribution of airflow and room temperature.
Drain pump is equipped as standard accessory with
600 mm lift.

Two types of optional high-efficiency filter are available


(65% and 95%, colourimetric method).
A long-life filter (maintenance free up to one year*) is
equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Individual airflow direction example case


Position 0

Position 2

600 mm
Position 3

25

Swing

L-shaped 2-way flow

Major maintenance work can be performed by removing


the panel. A flat-type suction grille and a detachable
blade make cleaning easy.

26

Indoor Unit Lineup


Slim Ceiling Mounted Duct Type

Ceiling Mounted Cassette Corner Type

Slim design, quietness and


static pressure switching

FXKQ25MA/FXKQ32MA
FXKQ40MA/FXKQ63MA

Suited to use in drop-ceilings!

Slim design for flexible installation


Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism realises even
distribution of airflow and room temperature.
(m)
3

Min.195 mm
Panel spacer
20 mm

Single-flow type allows effective air discharge


from corner or from drop-ceiling.
Drain pump is equipped as standard
accessory with 500 mm lift.

28C
32C 30C

26C

Only 700 mm in width and 23 kg in weight, this


model is suitable to install in limited spaces like
drop-ceilings in hotels.
Great for
hotel use!

22C
20C

Only

6 (m)

200 mm

700 mm

200 mm

900 mm

* 1,100 mm in width for the FXDQ63NB model.

Front discharge is possible with an air


discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.

Suspension bolt*

Air filter

240 mm

AIR

Main body
500 mm

Only 200 mm in height, this model can be installed in


rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.

24C

1
0

FXDQ40NB /FXDQ50NB / FXDQ63NB

Indoor Unit Lineup

Slim body needs only 220 mm space above the


ceiling. If you use a panel spacer (option), the
unit can be installed in the minimum space of
195 mm.

FXDQ20PB /FXDQ25PB /FXDQ32PB

Discharge grille *
AIR

Downward discharge

Suction grille *
* To be obtained locally

External static pressure selectable by remote controller


switching make this indoor unit a very comfortable and
flexible model.

Air discharge grille (Option)

10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.


15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.
Set for front discharge using a suspended ceiling.

Drain pump is equipped as standard accessory with


750 mm lift.

Main body

Air discharge grille


(Option)

Downward discharge is shut off and air is blown straight out


(front discharge).

A long-life filter (maintenance free up to one


year*) is equipped as standard accessory.

Control of the airflow rate has been improved from 2-step


to 3-step control.
Low operation sound level

750 mm

(dB(A))

FXDQ-PB/NB

20/25/32

40

50

63

Sound level
(HH/H/L)

33/31/29

34/32/30

35/33/31

36/34/32

Ceiling

* The values of operation sound level represent those for rear-suction operation.
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
of 15 Pa.

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

27

28

Indoor Unit
UnitsLineup
Ceiling Concealed (Duct) Type

Ceiling Mounted Built-in Type

FXSYQ20M/FXSYQ25M/FXSYQ32M
FXSYQ40M/FXSYQ50M /FXSYQ63M
FXSYQ80M/FXSYQ100M
FXSYQ125M

FXDYQ80MA/FXDYQ100MA
FXDYQ125MA/FXDYQ145MA
FXDYQ180M/FXDYQ200M
FXDYQ250M

High static pressure offers flexible duct design


that blends in with any interior dcor in stores and offices

Highly flexible for various application


Installation examples ( Optional parts)

Highly flexible installation is possible with a


complete lineup of optional kits to satisfy
various needs, such as the design concept,
interior decoration and so on.

Standard

Cassette style (standard filter)


Long-life lter

High efficiency Hi-X heat exchanger


coils that provide even more energy
savings.

Air suction
canvas bellows

The unit can be installed, if there is a space


of 350 mm above ceiling.
(when suction panel is used.)

Air suction panel

Cassette style (high efficiency filter)


High efciency
lter
Air suction
canvas bellows

With duct

Min.
350 mm

Air suction panel


Screening
door

Drain pump is equipped as standard


accessory with 250 mm lift.

Access panel

High external static pressure allows


comprehensive duct layout for various
applications.
120 Pa for FXDYQ80MA145MA
150 Pa for FXDYQ180M
180 Pa for FXDYQ200M
200 Pa for FXDYQ250M

Ceiling return

Indoor Unit Lineup

Long-life lter

Long-life lter
Access panel

Design of indoor units allows installation


in limited roof spaces.

250 mm

Return air spigots included for ease of


installation for FXDYQ80MA-145MA
models.
High external static pressure allows the use of flexible
ducts of various length.

Low operation sound level


FXSYQ-M
Sound level
(H/L)

20/25/32

40

41/33.5 41/34.5

(230 V)(dB(A))

50

63

80/100

125

43/37

45/38.5

48/43

49/41.5

The values of operation sound level are based on Australian Standard 1217.6-1985.
Measurement is based on bottom-return air entry.

29

Two external static pressure settings for


added flexibility.
Quiet yet powerful supply air fan.
High strength galvanised steel casing.

30

Indoor Unit Lineup


Ceiling Suspended Type

Ceiling Mounted Duct Type

FXMQ20P/FXMQ25P/FXMQ32P
FXMQ40P/FXMQ50P/FXMQ63P
FXMQ80P/FXMQ100P/FXMQ125P
FXMQ140P

FXHQ32MA/FXHQ63MA
FXHQ100MA

Slim body with quiet and wide airflow

Middle and high static pressure


allows for flexible duct design

Adoption of QUIET STREAM FAN


Uses the quiet stream fan and many
more advanced technologies.

A DC fan motor increases the external static


pressure capacity range to include middle to high
static pressures, increasing design flexibility.

Sound absorption
member

30 Pa100 Pa for FXMQ20P-32P


30 Pa160 Pa for FXMQ40P
50 Pa200 Pa for FXMQ50P-125P
50 Pa140 Pa for FXMQ140P

Drain pump is equipped as


standard accessory with
700 mm lift.

Control of the airflow rate has been improved


from 2-step to 3-step control.
Low operation sound level
(dB(A))
32

40

50

63

80/100

125

140

Sound
level 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43
(HH/H/L)

Energy-efficient
The adopted DC fan motor is much more efficient than
the conventional AC motor, yielding an approximate
20% decrease in energy consumption (FXMQ125P).

FXMQ200MA/FXMQ250MA

Quiet stream fan

Straightening vane

Low operation sound level

700 mm
Ceiling

FXMQ-P 20/25

Turbulent flow
is produced

Improved ease of installation


Airflow rate can be controlled using a remote controller during
test operation. With the conventional model, the airflow rate
was controlled from the PC board. It is automatically adjusted to
the range between approximately 10% of the rated HH tap
airflow for FXMQ20P125P.

Housing the drain pump inside the unit reduces the


space required for installation.

Without drain pump

32

63

100

Sound level
(H/L)

36/31

39/34

45/37

Installation is easy
Drain pump kit (option) can be easily incorporated.

600 mm

Wide air discharge openings produce a spreading 100


airflow.

470 mm

Simplified Static Pressure Control

External static pressure can be easily adjusted using


a change-over switch inside the electrical box to meet
the resistance in the duct system.

31

25 mm

Indoor unit

222 mm

Bristle-free Flap minimises


contamination and makes
cleaning simpler.

Non-dew Flap

Easy-to-clean flat design


Maintenance is easier because everything can be
performed from below the unit.

0250

470 mm

Maintenance is easy
Non-dew Flap with no implanted bristles

Drain pump kit


(built inside main unit)

With drain pump


mm

(dB(A))

FXHQ-MA

Improved ease of maintenance


The drain pan can be detached for easy cleaning. An
antibacterial treatment that uses silver ions has been applied to
the drain pan, preventing the growth of slime, mould and
bacteria that cause blockages and odours.
Built-in Drain Pump (Option)

Indoor Unit Lineup

All models are only 300 mm in height, an


improvement over the 390 mm height of
conventional models. The weight of the
FXMQ40P has been reduced from 44 kg to 28 kg.

100

A long-life filter (maintenance free up to one year*) is


equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Indoor unit

32

Indoor Unit Lineup


Floor Standing Type

Wall Mounted Type

FXAQ20P/FXAQ25P

FXLQ20MA/FXLQ25MA

FXAQ50P/FXAQ63P

FXLQ50MA/FXLQ63MA

FXLQ32MA/FXLQ40MA

FXAQ32P/FXAQ40P

Stylish flat panel design harmonised


with your interior dcor
Stylish flat panel design creates a graceful harmony that
enhances any interior space.
Flat panel can be cleaned with only the single pass of a
cloth across their smooth surface.
Flat panel can also be easily removed and washed for
more thorough cleaning.

The adoption of a fibre-less discharge grille featuring an


original design to prevent condensation also helps
prevent staining and makes cleaning easier.
A long-life filter (maintenance free up to one year*) is
equipped as standard accessory.

(dB(A))

FXAQ-P

20

25

32

40

50

63

Sound level
(H/L)

35/31

36/31

38/31

39/34

42/37

47/41

Floor Standing types can be hung on the wall for easier


cleaning. Running the piping from the back allows the
unit to be hung on walls. Cleaning under the unit, where
dust tends to accumulate, is considerably easier.

Wall hanging

* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

Floor installation

Concealed Floor Standing Type

Drain pan and air filter can be kept clean by mould-proof


polystyrene.

FXNQ20MA/FXNQ25MA

Vertical auto-swing realises efficiency of air distribution.


The louvre closes automatically when the unit stops.
5 steps of discharge angle can be set by remote
controller.
Discharge angle is automatically set at the same angle
as the previous operation when restarting. (Initial setting:
10 for cooling and 70 for heating)
Flexible installation
Drain pipe can be fitted to from either left or
right sides.

FXNQ32MA/FXNQ40MA
FXNQ50MA/FXNQ63MA
Drain pump kit is available as optional accessory, which
lifts the drain 1,000 mm from the bottom of the unit.
Height of drain-up

Designed to be concealed in the perimeter skirting-wall

1,000 mm

Drain pump kit

The unit is concealed in skirting-wall of perimeter, that


enables to create high class interior design.
Indoor unit

The connecting port faces downward,


greatly facilitating on-site piping work.
A long-life filter (maintenance free up
to one year*) is equipped as standard
accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

33

Indoor Unit Lineup

Low operation sound level

Suitable for perimeter zone air conditioning

Connecting
port
Refrigerant
piping
* Applies also to Floor Standing type (FXLQ-MA).

34

Indoor Unit Specifications


Indoor Units
Ceiling Mounted Cassette (Round Flow with Sensing) Type

kcal/h

Cooling capacity

Btu/h
kW

kcal/h

Heating capacity
Cooling

Power consumption

Heating

Casing

Sound power (H/M/L)


Dimensions (HWD)

12,300

2.8

2,800

Liquid (Flare)
Gas (Flare)

3,900

4,800

6,100

7,700

9,600

12,000

15,400

19,100

24,200

30,700

38,200

47,800

4,300

Dimensions(HWD)
Weight

8,600

10,800

13,800

12.5

16.0

13,600

17,100

21,500

27,300

34,100

3.2

4.0

5.0

6.3

8.0

10.0

0.031

0.041

0.080

0.095

0.194

0.219

0.027

0.037

0.075

0.090

0.180

0.199

kW
kW

dB(A)
dB(A)
mm

Galvanised steel plate

208/191/166

241/216/183 365/291/224 391/308/224 391/324/249 549/433/316 574/458/349


14.5/13.0/11.0 22.0/17.5/13.5 23.5/18.5/13.5 23.5/19.5/15.0 33.0/26.0/19.0 34.5/27.5/21.0

47/45.5/44
19

mm

12.7

Panel
(Option)

Power consumption
Casing

Cooling
Heating

Airflow rate (HH/H/L)


Sound level (HH/H/L)
Sound power (HH/H/L)
Dimensions (HWD)
Machine weight
Piping
connections

Panel
(Option)

3,900

4,800

6,100

7,700

9,600

12,000

Btu/h

9,600

12,300

15,400

19,100

2.8

3.6

4.5

5.6

24,200

30,700

38,200

47,800

kW

7.1

9.0

11.2

14.0

3,400

4,300

5,400

17,100

21,500

kW

3.2

4.0

Gas (Flare)

Weight

54,600

42,700

6.3

8.0

12.5

16.0

0.052

0.066

0.093

0.187

0.209

kW

0.027

0.034

0.038

0.053

0.075

0.174

0.200

/s

216/191/166

250/216/183 266/225/183 316/275/225 350/300/250 533/433/333 550/466/375

dB(A)

30/28.5/27

31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34

48/46.5/45

49/47/45 50/47.5/45 52/49/46 53/51.5/49 60/54.5/50 61/56/52

m3/min
dB(A)

13/11.5/10

mm

10.0

Galvanised steel plate


15/13/11 16/13.5/11 19/16.5/13.5 21/18/15

mm
19.5

246840840

32/26/20 33/28/22.5

288840840

22

6.4

25

9.5

12.7
15.9
VP25 (External Dia, 32/Internal Dia, 25)
BYCP125K-W1

Model
Dimensions(HWD)

13,800

10,800

5.0

Drain
Colour

34,100

0.047

kg

Liquid (Flare)

8,600

6,900

27,300

0.033

kW

Fresh white

mm

50X950X950

kg

5.5

Note: Specifications are based on the following conditions;


Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

35

8,500

10,900

2.5

3.2

0.073

3.6
3,400
13,600
4.0
0.076

4,800

3,900
15,400
4.5
17,100
5.0

21,500
6.3
0.115

0.089

183/133

233/166

240 V dB(A)

32/26

240 V dB(A)

49

34/28

37/29

42/35

0.064

Galvanised steel plate

9/7

9.5/7.5
51

mm

Dimensions(HWD)

11/8
54

kg

18

mm

12.7

59

6.4
VP20 (External Dia, 26/Internal Dia, 20)
BYFQ60B8W1

White (6.5Y9.5/0.5)
mm

55700700
2.7

kg

MODEL

1-phase, 220-240 V/220-230 V, 50/60 Hz

Btu/h
kW
kcal/h
Btu/h

Heating capacity

kW

6,900

9,600

27,300

38,200

8.0

11.2

7,700

10,800

30,700

42,700

9.0

Cooling

kW

Heating

0.090

kW

0.073

Casing

FXUQ100AVEB

FXUQ71AVEB
kcal/h

Cooling capacity

12.5

0.200
0.179
Fresh white

/s

375/325/267

517/433/350

m3/min

22.5/19.5/16

31/26/21

Sound level (H/M/L)

dB(A)

47/44/40

Sound power (H/M/L)

dB(A)

40/38/36

Dimensions (HWD)

mm

Airflow rate (H/M/L)

Machine weight

kg

Liquid (Flare)

Piping
Gas (Flare)
connections
Drain

14/10

286575575

Colour

Power
consumption

5.6

158/125

Power supply

This model is not


compatible both Heat
Pump 30 class and Heat
Recovery systems.

19,100
5,400

4,300

4-way Flow Ceiling Suspended Type

1-phase, 220-240 V/220 V, 50/60 Hz

3,100

13,600

2.8
2,800

3,100
12,300

150/116

/s

Weight

2,400

2,800

2.2
2,200

Model

5.5

10,900

9,600

0.107

Piping
Gas (Flare)
connections
Drain

50950950

Btu/h

7,500

FXZQ50MVE

0.080

Dimensions (HWD)

Fresh white

FXZQ40MVE

0.068

m3/min

Sound power (H)

FXZQ32MVE

1-phase, 220-240 V/220 V, 50/60 Hz

Liquid (Flare)

kcal/h

kcal/h

kW

Machine weight

FXFQ25PVE FXFQ32PVE FXFQ40PVE FXFQ50PVE FXFQ63PVE FXFQ80PVE FXFQ100PVE FXFQ125PVE

Power supply

Heating

Sound level (H/L)

BYCQ125B-W1

kg

kW

Airflow rate (H/L)

15.9

mm

Cooling

Casing

I.D. 25O.D. 32(VP25)

MODEL

Heating capacity

Power
consumption

9.5

Ceiling Mounted Cassette (Round Flow) Type

Cooling capacity

kW

26

23

2,400

Btu/h

Heating capacity

288840840

6.4

1,900

Btu/h
kW

48/46/44 53/49/45 55/50/45 55/52/48 60/54/48 61/56/51


246840840

FXZQ25MVE

kcal/h

31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35

30/28.5/27

FXZQ20MVE
kcal/h

Cooling capacity

54,600

42,700

12.5/11.5/10.0

Model
Colour

6,900

MODEL

Power supply

14.0

11.2

9.0

7.1

5,400

10,900

Drain

Panel
(Option)

5.6

4.5

3.6

3,400

kg

Machine weight
Piping
connections

3,100

9,600

kW

m3/min

Sound level (H/M/L)

2,400

Btu/h

/s

Airflow rate (H/M/L)

1-phase, 220 -240 V/220-230 V, 50/60 Hz

Indoor Unit Lineup

FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM

MODEL

Power supply

Ceiling Mounted Cassette (Compact Multi Flow) Type

58/56/54

65/62/58
198950950

26

27

9.5
mm

15.9
VP20 (External Dia, 26/Internal Dia, 20)

Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

36

Indoor Unit Specifications


Indoor Units
FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE

MODEL

1-phase, 220-240 V/220 V, 50/60 Hz

Power supply

kcal/h

1,900

2,400

3,100

3,900

4,800

6,100

7,700

12,000

Btu/h

7,500

9,600

12,300

15,400

19,100

24,200

30,700

47,800

kcal/h

2,200

2,800

3,400

4,300

5,400

6,900

8,600

13,800

Btu/h

8,500

10,900

13,600

17,100

21,500

27,300

34,100

54,600

kW
Cooling

2.5

3.2

4.0

5.0

6.3

8.0

10.0

16.0

kW

Heating

0.077

0.092

0.130

0.106

0.209

0.256

kW

0.044

0.059

0.097

0.126

0.176

0.223

Cooling capacity

kW
Heating capacity
Power
consumption

Slim Ceiling Mounted Duct Type (700 mm width type)

2.2

2.8

3.6

5.6

7.1

9.0

14.0

Galvanised steel plate

Casing

/s

Airflow rate (H/L)

m3/min

Sound level (H/L)

240 V

Dimensions (HWD)
Machine weight

dB(A)
mm

116/83

150/108

200/150

275/216

433/350

550/416

7/5

9/6.5

12/9

16.5/13

26/21

33/25

34/29

36/30

37/32

39/34

41/36

46/40

305990600

305775600
26.0

kg

31.0

Liquid (Flare)

Piping
Gas (Flare)
connections
Drain

mm

Colour
Weight

32.0

35.0

mm

531,030680

kg

8.0

3051,665600
47.0

48.0

6.4

9.5

12.7

15.9

BYBC32G-W1

Dimensions(HWD)

3051,175600

VP25 (External Dia, 32/Internal Dia, 25)

Model
Panel
(Option)

4.5

531,245680

531,430680

531,920680

8.5

9.5

12.0

Ceiling Mounted Cassette Corner Type


kcal/h

Cooling capacity

Btu/h
kW

kcal/h

Heating capacity
Power
consumption
Casing

Btu/h

Cooling

Heating

Airflow rate (H/L)


Sound level (H/L)

240 V

kW
kW

mm

kg

Dimensions(HWD)
Weight

3,900

mm
kg

6,100

12,300

15,400

24,200

2,800

3,400

4,300

6,900

2.8

3.6

10,900
3.2

13,600
4.0

0.066

11/9
40/35

4.5

7.1

17,100

27,300

0.076

0.105

5.0

0.056

Galvanised steel plate

216/166

215X1,110X710

13/10
42/36

31

6.4

12.7
VP25 (External Dia, 32/Internal Dia, 25)

Model

Colour

3,100

FXKQ63MAVE

9,600

183/150

Liquid (Flare)
Piping
connections Gas (Flare)
Drain
Panel
(Option)

2,400

/s

mm

FXKQ40MAVE

1-phase, 220 -240 V/220 V, 50/60 Hz

0.046

Dimensions (HWD)

Machine weight

FXKQ32MAVE

kW

m3/min
dB(A)

BYK45FJW1
White (10Y9/0.5)

8.0

0.085
300/250
18/15
44/39

215X1,310X710
34

9.5

15.9
BYK71FJW1

70X1,240X800

70X1,440X800

8.5

9.5

Note: Specifications are based on the following conditions;


Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

37

FXDQ20PBVE

Power consumption

Cooling
Heating

Casing
Airflow rate (HH/H/L)
External static pressure
Sound level (HH/H/L)

1 3

kcal/h

1,900

Btu/h

7,500

FXDQ25PBVE
1-phase, 220-240 V/220 V, 50/60 Hz
2,400

kW

2.2

2.8

3.6

2,200

2,800

3,400

Btu/h

8,500

10,900

13,600

kW

2.5

3.2

kW

0.086

kW

0.067

4.0
0.089
0.070

Galvanised steel plate

/s

133/120/106

m3/min

8.0/7.2/6.4

Pa

30-10

dB(A)

33/31/29
51

mm

200700620

kg

23.0

6.4

Liquid (Flare)

Piping
Gas (Flare)
connections
Drain

3,100
12,300

9,600

dB(A)

Sound power (HH)

FXDQ32PBVE

kcal/h

mm

12.7
VP20 (External Dia, 26/Internal Dia, 20)

Slim Ceiling Mounted Duct Type (900/1,100 mm width type)


MODEL

FXKQ25MAVE

MODEL

Power supply

Heating capacity

Machine weight

BYBC125G-W1

White (10Y9/0.5)

Cooling capacity

Dimensions (HWD)

BYBC63G-W1

BYBC50G-W1

MODEL

Power supply

FXDQ40NBVE

Power supply

Cooling capacity

Heating capacity
Power consumption

Cooling
Heating

Casing
Airflow rate (HH/H/L)
External static pressure
Sound level (HH/H/L)

1 3

Sound power (HH)

Dimensions (HWD)
Machine weight

Liquid (Flare)

Piping
Gas (Flare)
connections
Drain

FXDQ50NBVE

1-phase, 220-240 V/220 V, 50/60 Hz

FXDQ63NBVE

kcal/h

3,900

4,800

6,100

Btu/h

15,400

19,100

24,200

kW

4.5

5.6

7.1

kcal/h

4,300

5,400

6,900

Btu/h

17,100

21,500

27,300

kW

5.0

6.3

8.0

kW

0.160

0.165

0.181

kW

0.147

0.152

0.168

/s

175/158/141

m3/min

Galvanised steel plate


208/183/166

10.5/9.5/8.5

12.5/11.0/10.0

34/32/30

35/33/31

52

53

Pa

dB(A)
dB(A)
mm
kg
mm

27.0

44-15

200900620

6.4

Indoor Unit Lineup

Ceiling Mounted Cassette (Double Flow) Type

275/241/216

16.5/14.5/13.0

28.0

12.7

36/34/32
54

2001,100620
31.0

9.5

15.9

VP20 (External Dia, 26/Internal Dia, 20)

Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1: Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.
2: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is
10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.)
3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be
obtained by adding 5 dB(A).

38

Indoor Unit Specifications


Indoor Units
Ceiling Mounted Duct Type

MODEL

FXSYQ20MVE FXSYQ25MVE FXSYQ32MVE FXSYQ40MVE FXSYQ50MVE FXSYQ63MVE FXSYQ80MVE FXSYQ100MVE FXSYQ125MVE

Power supply

Cooling capacity

1-phase, 220-240 V, 50 Hz

kcal/h

1,900

2,400

3,100

Btu/h

7,500

9,600

12,300

kW
kcal/h
Btu/h

Heating capacity

kW
Power
consumption

Cooling

kW

Heating

kW

Casing

/s

Airflow rate (H/L)

m3/min
Pa

External static pressure

2.2

2.8

3.6

2,200

2,800

3,400

10,900

13,600

3.2

4.0

8,500
2.5

0.089

0.096

0.089

0.096

Piping
Gas (Flare)
connections
Drain

Weight

24,200

30,700

38,000

47,800

7.1

9.0

11.2

14.0

5,400

6,900

8,600

10,800

13,800

34,100

42,700

54,600

10.0

12.5

16.0

0.304

0.309

0.366

0.304

0.309

0.366

5.6

4.5
4,300

21,500

17,100

27,300

6.3

5.0

8.0

0.145

0.106

0.178

0.145

0.106

0.178

350/235

450/355

466/370

21/14.1

27/21.3

28/22.2 38/27.42

98-65-33

191/143

88-57-27

96-65-57

86-58-43

41/33.5

41/34.5

43/37

58/50.5

58/51.5

60/54

30

34

35

300X550X800

300X700X800

115-84-52

140-122-61

138-118-53

98-58

48/43

49/41.5

62/55.5

65.5/60

66/59

300X1,000X800

300X1,400X800

44

57

6.4

9.5

12.7

15.9

BYBS45DJW1

633/457

45/38.5

VP25 (External Dia, 32/Internal Dia, 25)

BYBS32DJW1

Dimensions(HWD)

19,100

250/190

mm

Colour

12,000

158/112

Model
Panel
(Option)

9,600

9.5/6.72 11.5/8.58 15/11.4

kg

Liquid (Flare)

7,700

9/6.72

mm

Machine weight

6,100

150/112

Sound power (H/L) 230 V dB(A)


Dimensions (HWD)

15,400

4,800

Galvanised steel plate

230 V dB(A)

Sound level (H/L)

3,900

BYBS71DJW1

White (10Y9/0.5)

55X650X500

55X800X500

55X1,100X500

55X1,500X500

3.0

3.5

4.5

6.5

Cooling capacity

kcal/h

7,600

9,600

12,000

13,800

17,200

19,300

24,100

Btu/h

30,000

38,200

47,400

54,600

68,200

76,400

95,500

kcal/h
Btu/h

Heating capacity

kW
Power
consumption

Cooling

kW

Heating

kW

Casing

/s

Airflow rate (H)

m3/min

External static pressure (H)


Sound level (H)
Machine weight
Liquid (Flare)
Piping
Gas (Flare)
connections
Drain

8,480
33,800

11.2

mm
kg
mm

13.9

10,800

13,800

42,700

54,600

12.5

16.0

0.700

0.780

0.415

0.700

0.780

510

778

30.6

46.7

45

46

50

60

9.9
0.415

120
360X1168X869

16.0

15,800
62,800
18.4
0.880

20.0

22.4

19,300

21,500

76,400

85,300

22.4

25.0

0.980

0.880

0.980

852

957

51.1

57.4

1.020

360X1478X899
65

15.9

9.5

VP25 (External Dia, 32/Internal Dia, 25)

107,500
31.5
1.200

1,180

1,200

1,400

70.8

72.0

84.0

180

200

51

66

27,100

1.200

150
48

28.0

1.020

Galvanised steel plate

Pa

240 V dB(A)

Dimensions (HWD)

8.8

500X1210X910

77

79

19.1

500X1410X910
98

22.2

BSP 3/4 inch internal thread

Note: Specifications are based on the following conditions;


Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: (FXSYQ) Anechoic chamber conversion value, based on Australian Standard 1217.6-1985. Measurement is based on bottom-return air entry.
(FXDYQ) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
For FXDYQ models, an air filter is not a standard accessory. A suitable locally obtained filter must be installed in the return air duct.
1: External static pressure is changeable to change over the connectors inside electrical box, this pressure means
"High static pressure-Standard-Low static pressure".
2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard".
3: External static pressure is changeable to change over the connectors inside electrical box (High static pressure-Standard static pressure).
The data above is for high static pressure setting.

39

1,900

2,400

3,100

3,900

4,800

Btu/h

7,500

9,600

12,300

15,400

19,100

kW

2.2

2.8

3.6

4.5

5.6

kcal/h

2,200

2,800

3,400

4,300

5,400

Btu/h

8,500

10,900

13,600

17,100

21,500

kW

2.5

3.2

4.0

5.0

6.3

0.060

0.151

0.128

0.073

0.182

0.203

158/133/116

267/216/183

300/275/250

9.5/8/7

16/13/11

Cooling

kW

0.056

Heating

kW

0.069

Casing
Airflow rate (HH/H/L)
External static pressure
Sound level (HH/H/L)
Sound power (H)

Dimensions (HWD)

Power supply

FXDYQ80MAV1 FXDYQ100MAV1 FXDYQ125MAV1 FXDYQ145MAV1 FXDYQ180MV1 FXDYQ200MV1 FXDYQ250MV1

kW

Power consumption

kcal/h

/s

9/7.5/6.5

Pa

30-100 (50)

dB(A)
dB(A)

30-160 (100)

33/31/29

34/32/30

51

52

mm

18/16.5/15
2

39/37/35

300X550X700
25

kg

50-200 (100)

41/39/37

57

59

300X700X700

300X1,000X700

28

36

6.4

mm

12.7
VP25 (External Dia, 32/Internal Dia, 25)

FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE


1-phase, 220-240 V/220 V, 50/60 Hz

kcal/h

Cooling capacity

Btu/h
kW

Heating capacity

Power consumption

Galvanised steel plate

150/125/108

m3/min

MODEL

Ceiling Concealed (Duct) Type


1-phase, 220 -240 V, 50 Hz

Heating capacity

Piping
connections Gas (Flare)
Drain

kg

Power supply

Cooling capacity

Liquid (Flare)

mm

MODEL

1-phase, 220-240 V/220 V, 50/60 Hz

Machine weight

BYBS125DJW1

FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE

MODEL
Power supply

Cooling
Heating

6,100

7,700

9,600

12,000

13,800

24,200

30,700

38,200

47,800

54,600

7.1

9.0

11.2

14.0

16.0

kcal/h

6,900

8,600

10,800

13,800

15,500

Btu/h

27,300

34,100

42,700

54,600

61,400

kW

8.0

10.0

12.5

16.0

18.0

kW

0.138

0.185

0.215

0.284

0.405

kW

0.218

0.286

0.364

0.449

0.449
766/649/533

Indoor Unit Lineup

Ceiling Mounted Built-in Type

Galvanised steel plate

Casing
Airflow rate (HH/H/L)
External static pressure
Sound level (HH/H/L)
Sound power (H)

Dimensions (HWD)
Machine weight
Liquid (Flare)

Piping
connections Gas (Flare)
Drain

/s

m3/min
Pa

dB(A)
dB(A)
mm
kg
mm

325/292/267

417/375/333

533/450/383

650/550/466

19.5/17.5/16

25/22.5/20

32/27/23

39/33/28

50-200 (100)

46/39/32
50-140 (100)

42/40/38

43/41/39

44/42/40

46/45/43

60

61

62

64

300X1,400X700

300X1,000X700
36

46

47

9.5
15.9
VP25 (External Dia, 32/Internal Dia, 25)

Note: Specifications are based on the following conditions;


Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1: Power consumption values are based on conditions of rated external static pressure.
2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static
pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.

40

Indoor Unit Specifications


Indoor Units
Ceiling Mounted Duct Type

Wall Mounted Type


FXMQ200MAVE

MODEL

19,300

kW

Power consumption
Casing

Cooling
Heating

Btu/h

85,300

107,500

kW

25.0

kW

1.294

kW

1.294

240 V

Dimensions (HWD)
Machine weight

Piping
connections Gas (Flare)
Drain

1.465

1.465

Heating capacity
1

Power consumption

Pa

966/833

1,200/1,033

58/50

72/62

132-221

dB(A)

191-270

3,100

3,900

4,800

6,100

7,500

9,600

12,300

15,400

19,100

24,200

kcal/h

2,200

2,800

3,400

4,300

5,400

6,900

Btu/h

8,500

10,900

13,600

17,100

21,500

27,300

kW

2.5

3.2

4.0

5.0

6.3

8.0

kW

0.019

0.028

0.030

0.020

0.033

0.050

kW

0.029

0.034

0.035

0.020

0.039

0.060

/s

m3/min
dB(A)

Sound level (H/L)

Dimensions (HWD)
Machine weight

470X1,380X1,100

mm

2.2

2.8

Piping
connections Gas (Flare)
Drain

9.5

19.1

22.2

3.6

4.5

5.6

7.1

White (3.0Y8.5/0.5)
125/75

133/83

142/91

200/150

250/200

316/233

7.5/4.5

8/5

8.5/5.5

12/9

15/12

19/14

35/31

36/31
290795238

38/31

39/34

42/37
2901,050238

47/41

kg

11.0

Liquid (Flare)

137

mm

Heating

Airflow rate (H/L)

49/46

mm

Cooling

Casing

Galvanised steel plate

kg

Liquid (Flare)

31.5

2,400

kW

27,100

1-phase, 220-240 V/220 V, 50/60 Hz

1,900

Btu/h

28.0

21,500

m3/min

External static pressure


Sound level (H/L)

22.4

FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE


kcal/h

Cooling capacity

95,500

kcal/h

/s

Airflow rate (H/L)

24,100

76,400

Btu/h

Heating capacity

MODEL

Power supply

1-phase, 220 -240 V/220 V, 50/60 Hz

kcal/h

Cooling capacity

FXMQ250MAVE

14.0

6.4

9.5

12.7

mm

15.9

VP13 (External Dia, 18/Internal Dia, 13)

PS1B

Floor Standing Type/Concealed Floor Standing Type


Ceiling Suspended Type
FXHQ32MAVE

MODEL
Power supply

kcal/h

Cooling capacity

Heating

Casing
Airflow rate (H/L)

9,600

38,200

3.6

7.1

11.2

kW
kW
kW
/s

m3/min

Machine weight

kg

Piping
connections Gas (Flare)
Drain

6,100

24,200

dB(A)

Liquid (Flare)

3,100

12,300

Sound level (H/L)

Dimensions (HWD)

FXHQ100MAVE

kW
Btu/h
Cooling

FXHQ63MAVE
1-phase, 220-240 V/220 V, 50/60 Hz

Btu/h
kcal/h

Heating capacity

Power consumption

mm

3,400

6,900

10,800

13,600

27,300

42,700

4.0

8.0

12.5

0.111

0.115

0.135

0.111

0.115

0.135

200/166

291/233

416/325

12/10

17.5/14

25/19.5
45/37

36/31

39/34

195960680

1951,160680

24.0

28.0

6.4

mm

White (10Y9/0.5)

12.7

1951,400680
33.0
9.5
15.9

VP20 (External Dia, 26/Internal Dia, 20)

Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book
for details.)
Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXHQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions
1: Power consumption values are based on conditions of rated external static pressure.
2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".

41

FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE

MODEL
Power supply
FXLQ

FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE


kcal/h

Cooling capacity

Btu/h
kW

Heating capacity
FXNQ

Power consumption

Cooling
Heating

Casing

Sound level (H/L)


Dimensions
(HWD)

FXNQ

Machine weight

FXLQ

FXNQ

3,900

4,800

6,100

9,600

12,300

15,400

19,100

24,200

2.2

2.8

3.6

4.5

5.6

7.1

2,800

3,400

4,300

5,400

6,900

Btu/h

8,500

10,900

13,600

17,100

21,500

27,300

kW

2.5

3.2

4.0

5.0

6.3

8.0

kW

0.049

0.090

0.110

kW

0.049

0.090

0.110

dB(A)
mm
kg

Liquid (Flare)

Piping
connections Gas (Flare)
Drain

3,100

7,500
2,200

m3/min
FXLQ

2,400

kcal/h

/s

Airflow rate (H/L)

1-phase, 220-240 V/220 V, 50/60 Hz

1,900

mm

Indoor Unit Lineup

Power supply

FXLQ: Ivory white (5Y7.5/1)/FXNQ: Galvanised steel plate


116/100

133/100

183/141

233/183

266/200

7/6

8/6

11/8.5

14/11

16/12

35/32

38/33

39/34

40/35

6001,000222

6001,140222

6001,420222

610930220

6101,070220

6101,350220

19.0

23.0

27.0

25.0

30.0

36.0

6.4

9.5

12.7

15.9

VP13 (External Dia, 18/Internal Dia, 13)

Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book
for details.)
Sound level: (FXAQ-P) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
(FXLQ-MA, FXNQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.

42

Indoor Unit Option List


Indoor Units
No.
1
2
3
4

5
6
7

Type FXFQ25S FXFQ32S FXFQ40S FXFQ50S FXFQ63S FXFQ80S FXFQ100S FXFQ125S

Item

Decoration panel
Sealing material of air discharge outlet
Panel spacer
Filter related
High efficiency filter unit 65%
High efficiency filter unit 90%
Replacement high efficiency filter 65%
Replacement high efficiency filter 90%
Filter chamber
Long life replacement filter
Ultra long-life filter
Replacement ultra long-life filter
Fresh air intake kit
Chamber type Without T joint-pipe and fan
With T joint-pipe without fan
Direct installation type
Branch duct chamber
Insulation kit for high humidity

Slim Ceiling Mounted Duct Type (700 mm width type)


No.
1

BYCQ125B-W1
KDBHQ55B140
KDBP55H160FA
KAFP556B80
KAFP557B80
KAFP552B80
KAFP553B80
KDDFP55B160
KAFP551K160
KAFP55B160
KAFP55H160H
KDDQ55B140
KDDP55B160K
KDDP55X160
KDJP55B80
KDTP55K80

KAFP556B160
KAFP557B160
KAFP552B160
KAFP553B160

1
2
3
4

5
6
7
8

Decoration panel
Sealing material of air discharge outlet
Panel spacer
Filter related
High efficiency filter unit 65%
High efficiency filter unit 90%
Replacement high efficiency filter 65%
Replacement high efficiency filter 90%
Filter chamber
Long life replacement filter
Ultra long-life filter
Replacement ultra long-life filter
Fresh air intake kit
Chamber type Without T joint-pipe and fan
With T joint-pipe without fan
Direct installation type
Branch duct chamber
Chamber connection kit
Insulation kit for high humidity

No.
1

No.

KDJP55B160
KDTP55K160

BYCP125K-W1
KDBH55K160F
KDBP55H160FA
KAFP556B80
KAFP557B80
KAFP552B80
KAFP553B80
KDDFP55B160
KAFP551K160
KAFP55B160
KAFP55H160H
KDDP55B160
KDDP55B160K
KDDP55X160
KDJP55B80
KKSJ55KA160
KDTP55K80

KAFP556B160
KAFP557B160
KAFP552B160
KAFP553B160

KDTP55K160

Ceiling Mounted Cassette (Compact Multi Flow) Type


No.
1
2
3
4
5

Type

Item

4-way Flow Ceiling Suspended Type


No.
1
2
3

FXZQ20M

FXZQ25M

Decoration panel
Sealing material of air discharge outlet
Panel spacer
Replacement long-life filter
Fresh air intake kit
Direct installation type

Item

FXZQ32M

FXZQ40M

FXZQ50M

BYFQ60B8W1
KDBH44BA60
KDBQ44BA60A
KAFQ441BA60
KDDQ44XA60

Type

FXUQ71A

1
2

Decoration panel
Filter related

High efficiency filter 65% 1


High efficiency filter 90% 1
Filter chamber bottom suction
Long life replacement filter

Note: 1 Filter chamber is required if installing high efficiency filter.

FXCQ20M
FXCQ25M

43

Item

Panel related

Air inlet and air


discharge outlet related

Type

Decoration panel
Panel spacer
Long life replacement filter
Air discharge grille
Air discharge blind panel
Flexible duct (with shutter)

Air inlet related

BYBC32G-W1
KAFJ532G36
KAFJ533G36
KDDFJ53G36
KAFJ531G36

FXCQ50M

BYBC50G-W1
KAFJ532G56
KAFJ533G56
KDDFJ53G56
KAFJ531G56

FXCQ63M

No.
1

FXKQ32MA
BYK45FJW1
KPBJ52F56W
KAFJ521F56
K-HV7AW
KDBJ52F56W
KFDJ52FA56

Decoration panel
Access panel
High efficiency filter 65% 1
High efficiency filter 90% 1
Long life replacement filter
Filter chamber for bottom suction
Air suction canvas
Screening door

BYBC63G-W1
KAFJ532G80
KAFJ533G80
KDDFJ53G80
KAFJ531G80

FXCQ125M

BYBC125G-W1
KAFJ532G160
KAFJ533G160
KDDFJ53G160
KAFJ531G160

FXKQ40MA

FXDQ63NB

FXSYQ20M
FXSYQ25M
FXSYQ32M

BYBS32DJW1
KTBJ25K36W
KAFJ252L36
KAFJ253L36
KAFJ251K36
KAJ25L36D
KSA-25K36
KBBJ25K36

KDT25N63

FXSYQ40M
FXSYQ50M

FXSYQ63M

BYBS45DJW1
KTB25KA56W
KAF252LA56
KAF253LA56
KAFJ251K56
KAJ25LA56D
KSA-25KA56
KBBJ25KA56

BYBS71DJW1
KTB25KA80W
KAF252LA80
KAF253LA80
KAFJ251K80
KAJ25LA80D
KSA-25KA80
KBBJ25KA80

FXSYQ80M
FXSYQ100M
FXSYQ125M
BYBS125DJW1
KTB25KA160W
KAF252LA160
KAF253LA160
KAFJ251K160
KAJ25LA160D
KSA-25KA160
KBBJ25KA160

Type FXDYQ80MA FXDYQ100MA FXDYQ125MA FXDYQ145MA FXDYQ180M FXDYQ200M FXDYQ250M

Item

Run/fault status PCB

KRP1B5X

Ceiling Mounted Duct Type

Type

Item

1
2

Drain pump kit


High efficiency filter

3
4
5
6

Filter chamber
Long life replacement filter
Long life filter chamber kit
Service panel

Air discharge adaptor

65%
90%

White
Fresh white
Brown

Item

No.
1

Item

Drain pump kit

Item

Long life replacement filter

Concealed Floor Standing Type


No.

Type

Drain pump kit


Replacement long-life filter (Resin net)
L-type piping kit (for upward direction)

Floor Standing Type

FXKQ25MA

Type

Ceiling Concealed (Duct) Type

No.

FXCQ80M

FXDQ50NB

1 If installing a high efficiency filter in the Ceiling Mounted Built-in type, a filter chamber for bottom suction is required.

FXCQ40M

FXDQ32PB

KDT25N50

Wall Mounted Type

Ceiling Mounted Cassette Corner Type


No.

Filter related

1
2
3

KDBHP49B140
KDBTP49B140
KAFP551K160

Type

Item

No.

Ceiling Mounted Cassette (Double Flow) Type


No.

Item

Panel related

Note:

FXDQ40NB

Insulation kit for high humidity

Ceiling Suspended Type

FXUQ100A

Sealing material of air discharge outlet


Decoration panel for air discharge
Replacement long-life filter

Type

Item

No.

KDJP55B160

FXDQ25PB
KDT25N32

Ceiling Mounted Built-in Type

Type FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125P

Item

FXDQ20PB

Insulation kit for high humidity

Slim Ceiling Mounted Duct Type (900/1,100 mm width type)

Ceiling Mounted Cassette (Round Flow) Type


No.

Type

Item

Item

Long life replacement filter

FXMQ20P
FXMQ25P
FXMQ32P

FXMQ40P

KAF372AA36
KAF373AA36
KDDF37AA36
KAF371AA36
KAF375AA36
KTBJ25K36W
KTBJ25K36F
KTBJ25K36T
KDAJ25K36A

KAF372AA56
KAF373AA56
KDDF37AA56
KAF371AA56
KAF375AA56
KTB25KA56W
KTBJ25K56F
KTBJ25K56T
KDAJ25K56A

FXHQ32MA
KDU50N60VE
KAF501DA56
KHFP5MA63

Type

FXAQ20P

Type FXLQ20MA

FXMQ50P
FXMQ63P
FXMQ80P
KAF372AA80
KAF373AA80
KDDF37AA80
KAF371AA80
KAF375AA80
KTB25KA80W
KTBJ25K80F
KTBJ25K80T
KDAJ25K71A

FXHQ63MA
KAF501DA80

FXMQ100P
FXMQ125P
FXMQ140P

FXMQ200MA
FXMQ250MA

KAF372AA160
KAF373AA160
KDDF37AA160
KAF371AA160
KAF375AA160
KTB25KA160W
KTBJ25K160F
KTBJ25K160T
KDAJ25K140A

KDU50N125VE
KHFP5MA160

KDU30L250VE
KAFJ372L280
KAFJ373L280
KDJ3705L280
KAFJ371L280

FXHQ100MA
KAF501DA112

FXAQ25P

FXAQ32P

FXAQ40P

FXAQ50P

FXAQ63P

FXLQ25MA

FXLQ32MA

FXLQ40MA

FXLQ50MA

FXLQ63MA

KAFJ361K28

K-KDU572EVE

KAFJ361K45

Indoor Unit Lineup

Ceiling Mounted Cassette (Round Flow With Sensing) Type

KAFJ361K71

Type FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA


KAFJ361K28

KAFJ361K45

KAFJ361K71

FXKQ63MA
BYK71FJW1
KPBJ52F80W
KAFJ521F80
K-HV9AW
KDBJ52F80W
KFDJ52FA80

44

Control Systems
Individual Control Systems for Indoor Units
Convenience

Nav Ease (Wired remote controller) (Option)


This simple, contemporary remote controller with fresh white colour
matches your interior design. The clear, backlight display with large
easy-to-read text makes navigation easy and provides one-touch control
over your in-home comfort.

Clear display
Dot matrix display

A combination of fine dots enables various


icons.Large text display is easy to see.

Setback (default:OFF)

Maintains the room temperature in a specific range during unoccupied period


by temporarily starting air conditioner that was turned OFF.
Ex) Setback temperature Cooling : 35C
Recovery differential Cooling : -2C
When the room temperature goes above 35C, the air conditioner starts operating in Cooling automatically.
When room temperature reaches 33C, the air conditioner returns OFF.

Setback
temperature

Recovery
differential

Cooling

33

37C

-2

-8C

Heating

10

15C

+2

+8C

Weekly schedule

Backlight display

Backlight display helps operating in


dark rooms.

5 actions per day can be scheduled for each day of the week.
The holiday function will disable schedule timer for the days that have been set as holiday.
3 independent schedules can be set. (e.g. summer, winter, mid-season)
College classroom sample (a summer Monday case)

BRC1E62

1) 8:30

ON

2) 10:00

The first period starts and the


air conditioner starts the cooling
operation.

ON

Simple operation

OFF

3) 13:00

In the second period, the classroom


is unoccupied and the air conditioner
stops.

ON

4) 15:00

When the third period starts,


operation starts again.

OFF

ON

OFF

After the third period, the classroom


becomes vacant again and the
air conditioner stops.

OFF

Large buttons and arrow keys

Large buttons and arrow keys enable easy operation. Basic setting such as fan
speed and temperature can be intuitively operated. For other settings just select
the function from the menu list.

Guide on display

The display gives an explanation of each setting for easy operation.

Multingual display

Energy saving

11 display languages are available. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish and Polish)

Until now only the temperature for one point could be set, but now the new
remote controller (BRC1E62) allows the setting of both Cooling and Heating,
and with the fan operation, mid-range temperatures are comfortable and
operation is more energy efficient.

20C

26C

Fan operation

operation

Saves energy by limiting the min. and max.


set temperature.
Avoids excessive cooling or heating.
This function is convenient when the remote
controller is installed at a place where any
number of people may operate it.

Individual airflow direction (*1)

Cooling / Heating

Heating

Setpoint range set

Comfort

2 setpoints

Airflow direction of each of the four air outlets can be controlled individually.
(Positions 0 to 4, Swing, and No individual setting are selectable.)
Cooling
operation

Setpoint auto reset

Even if the set temperature is changed, it returns


to the preset temperature after a preset period of
time.
Period selectable from 30 min / 60 min / 90 min /
120 min.

Outlet mark

Control Systems

Auto operation mode

Restaurant sample
Restaurant opened
Temperature is set to 27C

27 C

Full tables at lunchtime


Then is lowered to 24C
for crowded room

24 C

After 30 minutes*
Automatically returns to preset
temperature (27C) Returns to
27 C

Off timer

Turns off the air conditioner after a preset


period of time.
Period can be preset from 30 to 180 minutes
in 10-minute increments.

03
45

automatically

Auto airflow rate (*1)


*Setting possible for after 30, 60, 90,
and 120 minutes.

Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.
*1 Only available for 4-Way Flow Ceiling Suspended type FXUQ-A series and Ceiling Mounted Cassette (Round Flow with Sensing) type FXFQ-S series.

04
46

Control Systems
Individual Control Systems for Indoor Units
Wireless remote controller (Option)

The wired remote controller supports a wide range of control functions


Control of Cool/Heat
changeover

The same operation modes and settings as with wired remote controllers are
possible.

In all the series of GHP, Cool/Heat changeover in the same refrigerant circuit can be changed by the remote
controller of the indoor unit.

Outdoor
unit

* Individual airflow direction, auto airflow rate and sensing sensor control can be set only via wired remote controller
BRC1E62. Cannot be set via other remote controllers.

A compact signal receiver unit (separate type) to be mounted into a wall or ceiling
is included.

Group control
One remote controller can control the
operation of max.16 indoor units at the
same time.

Equipment
related to the
central control

A signal receiver unit (installed type) for a Ceiling Mounted Cassette (Round Flow,
Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall
Mounted type is mounted into the indoor unit.

Signal receiver unit can be


installed on the panel

Signal receiver unit


(Separate type)

Remote controller

Indoor unit

Remote controller

* Wireless remote controller and signal receiver unit are sold as a set.

* Refer to page 55 for the name of each model.

Forced OFF
input

Remote controller

Remote
controller

Remote controller

Heat Reclaim
Ventilator
Concealed type

Remote
controller

(For hotel use)


(BRC3A61)

Exposed type
(BRC2C51)

Signal receiver unit


(Installed type)

Simplified remote controller (Option)

Remote
controller

Remote
controller

ex. Ceiling Mounted Cassette (Round Flow) type

Wireless remote
controller

The remote controller


has centralised its
frequently used operation
selectors and switches
(on/off, operation mode,
temperature setting and
airflow volume), making
itself suitable for use in
hotel rooms or
conference rooms.

The concealed type remote controller smartly fits into a


night table or console panel in a hotel room.

The exposed type remote


controller is fitted with a
thermostat sensor.

Control by two remote controller

The indoor unit can be connected by the two remote


controller, for example one in the room and the other one
in the control room, which can control the operation of
indoor unit freely.(The last command has a priority.)
Of course, the group control by two remote controller is
also possible.

Remote control

The wiring of remote controller can be extended to max.


500 m and it is possible to install the remote controllers
for the different indoor units in one place.

FXFQ-S FXFQ-P

Nav Ease

(Wired remote controller)


(BRC1E62)

Wireless remote controller*

(Installed type signal receiver unit)

FXZQ

FXCQ

FXUQ

FXKQ

FXDQ

FXSYQ

FXDYQ

FXMQ

FXHQ

FXAQ

FXL(N)Q

Control Systems

Wide variation of remote controllers for indoor units

Wireless remote controller*

(Separate type signal receiver unit)

Simplified remote controller

Control for the combined operation

The operation of Heat Reclaim Ventilator can be


controlled by the remote controller of the indoor unit.
Of course, the remote controller can display the time to
clean the filter.

03
47

Expansion of system control

The system can be expanded to add several


controllers, such as BMS, Forced OFF input and etc.

(Exposed type)

(BRC2C51)

Simplified remote controller

(Concealed type: for Hotel use)


(BRC3A61)
*Refer to page 55 for the name of each model.

04
48

Control Systems
Centralised Control Systems for Indoor Units
Up to 64 groups of indoor units (128 units) can be centrally controlled.
Optional controllers for centralised control can be combined
freely, and system can be designed in accordance with building
scale and purpose.

System integration with various air-conditioning peripheral


equipment such as Heat Reclaim Ventilator is easy.

Wiring can be run up to a total length of 2 km, and adapts

DCS302CA61

Connection of
up to 8 units
possible

Independent
and centralised
control of Heat
Reclaim
Ventilator is
possible.

Address setting of central control can be


performed from the remote controller.
System without remote control is also available.

Max. 16 groups of indoor units can be operated


simultaneously/individually.

Group control of up to 16 units is possible


(group control via automatic address setting)

8 units

Schedule timer 1 unit

The VRV system can be combined.


DCS301BA61

Up to 2 units
connectable

Central control
adaptor kit
(DTA107A55).

Outdoor-air
processing
unit can be
connected.

7 cores max.

Unification adaptor for


computerised control (DCS302A52)

Interlink Building Management System


(host computer monitor panel) also
possible

Certain indoor units limit the functions of some control systems.

For more details, please refer to the Engineering Data.

03
49

Schedule timer (Option)


Max. 128 indoor units can be operated as programmed schedule.

Max. 128 indoor units controllable


When used in combination with a central remote controller, a maximum of 8 weekly

Interface adaptor for SkyAir


series
(DTA112BA51)

6 cores
Schedule timer (DST301BA61)
1 unit connection possible;
8 weekly schedule control patterns possible

Wiring adaptor
for other airconditioners
(DTA103A51)

Max. 16 groups (128 indoor units) controllable


2 remote controllers can be used to control from 2 different places.
Operating status indication (Normal operation, Alarm)
Centralised control indication
Max. wiring length 1,000 m (Total: 2,000 m)
Compact size casing (Thickness: 16 mm)
Connectable with Central Remote controller, Schedule timer and BMS system

DST301BA61

schedule patterns can be set, while the central controller can be used to select desired
zones. Up to 2 ON/OFF pairs can be set per day.
Max. 48 hours back up power supply
Max. wiring length 1,000 m (Total: 2,000 m)
Compact size casing (Thickness: 16 mm)
Connectable with Central Remote controller, Unified ON/OFF controller and BMS
system

Control Systems

Forced
shut-down
input

Central remote
controller
(DCS302CA61)

Max. 64 groups (128 indoor units) controllable


Max. 128 groups (128 indoor units) are controllable by using 2 central remote
controllers, which can control from 2 different places.
Zone control
Malfunction code display
Max. wiring length 1,000 m (Total: 2,000 m)
Connectable with Unified ON/OFF controller, schedule timer and BMS system
Airflow volume and direction can be controlled individually for indoor units in each group
operation.
Ventilation volume and mode can be controlled for Heat Reclaim Ventilator.
Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer.

Unified ON/OFF controller (Option)

Connectable number of
centralised control
equipment

Unified on/off
controller

Max. 64 groups (zones) of indoor units can be controlled individually same as


LCD Remote controller.

easily to large-scale system expansion.

Unified on/off
controller
(DCS301BA61)

Central remote 2 units


controller

Central remote controller (Option)

04
50

Control Systems
Advanced Control Systems for Indoor Units
Interface for

Communication functions in the user-friendly icon-based multilingual controller


simplify centralised control of the GHP system.

BACnet

and LONWORKS

Integrated control systems that recognise the trend of open control systems
Ethernet

Please contact Daikin for compatibility with BMS system

BMS

DCS601C51

Lift
Pump
Lighting,etc
Fire alarm Security Power supply facility

DMS502B51

DMS504B51

(Interface for use in BACnet) (Interface for use in LONWORKS)

GHP System

Local Controller
D -NET

D -NET Plus Adaptor


DCS601A52 (Option)

Indoor Unit

Number of indoor units expanded from 64 to 128.

Features
Colour LCD touch panel icon display
Small manageable size
Simplified engineering
Multi language (English, French, Italian, German, Spanish,

Heat Reclaim
Ventilator

Compatibility with BMS enhanced by utilising the international communication standards, BACnet or LONWORKS.
DMS502B51

Interface for use in BACnet

DMS504B51

Interface for use in LONWORKS

Support for Heat Reclaim Ventilator VAM series


Selectable temperature unit
BTL Certification
PPD data (Optional Di board is required.)
ISO 16484-5 (Does not support IEEE 802.3 protocol for BACnet)
Up to 40 outdoor units and 256 indoor unit groups on one gateway (optional adaptor)
XIF file for confirming of specifications of the units.
Connectable up to 10 outdoor units and 64 indoor unit groups.

Control Systems

RS-232C

Heat
Reclaim
Ventilator

Dutch, Portuguese, Chinese and Korean)

Yearly schedule
Auto heat/cool change-over
Temperature limitation
Enhanced history function
Built-in modem for connecting to Air Conditioning Network Service System (Option)
Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option)

03
51

04
52

Control Systems
Integrated Building Monitoring System
DIII-NET Line

The high speed transmission of DIII-NET enables more advanced control of the GHP system, providing
you with enhanced comfort.

BACnet/Ethernet or LONWORKS
Network Communication Line
Contact Signal Line

The DIII-NET system provides for:

Close control and monitoring by integrating a wide variety of air-conditioners in the entire building.
Saving the in-building cabling using non-polar, two-wire cables. Easier wiring work with
tremendously fewer wiring errors.
Additional setups readily up and running. An extendable cabling up to 2 km in total.
Different control equipment flexibly joined in the system for hierarchical risk diversification.
Daikin's total heat exchangers and other devices under integral control.

GHP

Controllers for Centralised Control

Heat Reclaim Ventilator

(DCS601C51)

D -NET

(High Speed Multiple


Transmission)

(DCM601A51)
Unified ON/OFF
Controller
(DCS301BA61)

Schedule Timer
(DST301BA61)

Control /Connection Interface


Unification adaptor
for computerised control
(DCS302A52)

DIII-NET, Daikins unique


high speed multiple
transmission system, links
air conditioners and
various other building
equipmentin
accordance with
applications, scale and
conditionsand transmits
vast amounts of
information between them.

BMS

Interface Adaptor for SkyAir Series


(DTA112BA51)

* No adaptor is required for the


FCQ-B and FHQ-BV.

Central Control Adaptor Kit


(DTA107A55)

Interface Adaptor for DIII-NET use


(KRP928BB2S)

(Obtain locally)

SkyAir

Packaged
Air-conditioner

Residential Air-conditioner

Interface for use in BACnet


(DMS502B51)
Di unit (DEC101A51)
Dio unit (DEC102A51)
Interface for use in LONWORKS
(DMS504B51)
GHP

Wiring adaptor
for electrical appendices
(KRP2A61/62/53)

03
53

Control Systems

Central Remote
Controller
(DCS302CA61)

VRV

Building services equipment

Electrical equipment
Supply water and drainage equipment
Automatic fire alarm
Parking equipment
Lift
Ventilation equipment
Lighting
Crime and fire prevention equipment

Caution:
Limitation may apply to some models and functions. Please contact your local sales office for details.
Consultation is necessary before employing this control system. Please contact your local sales office before
making a purchase.
Note: BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning
Engineers (ASHRAE). LONWORKS is a trademark of Echelon Corporation registered in the United
States and other countries.

04
54

Control Systems
Option List
Operation Control System Optional Accessories
No.
1
2
3
4
5
6-1
6-2
7

Item

Type

Wireless
Remote controller
Navigation remote controller (Wired remote controller)
Simplied remote controller (Exposed type)
Remote controller for hotel use (Concealed type)
Adaptor for wiring
Wiring adaptor for electrical appendices (1)
Wiring adaptor for electrical appendices (2)
Remote sensor (for indoor temperature)

Installation box for adaptor PCB

9
10

External control adaptor for outdoor unit


Adaptor for multi tenant

No.
1
2
3
4
5
6-1
6-2
7

Item

Type

Remote controller
Wireless
Navigation remote controller (Wired remote controller)
Simplied remote controller (Exposed type)
Remote controller for hotel use (Concealed type)
Adaptor for wiring
Wiring adaptor for electrical appendices (1)
Wiring adaptor for electrical appendices (2)
Remote sensor (for indoor temperature)

Installation box for adaptor PCB

External control adaptor for outdoor unit

10

Adaptor for multi tenant

FXFQ-S

FXFQ-P

FXZQ-M

FXUQ-A

FXCQ-M

FXKQ-MA

BRC7F634F BRC7F634F BRC7E530W BRC7CB58 BRC7C62


BRC4C61
BRC1E62 Note 7

KRP1B61
KRP1C63
KRP1BA57
KRP1B61

KRP2A61
KRP2A62
KRP2A62
KRP2A61
KRP4AA53
KRP4AA53 KRP4AA53 KRP4AA51 KRP4AA51
KRCS01-4B
KRCS01-1B KRCS01-4B
KRCS01-1B
Note 2, 3

Note 4, 6

KRP1H98
DTA104A62
DTA114A61

KRP1BA101
DTA104A62

FXSYQ-M

FXDYQ-M(A)

FXMQ-P

BRC4C62

BRC4C62

BRC4C65

Note 5

BRC2C51
BRC3A61
KRP1C64
KRP2A61
KRP4AA51
KRCS01-4B

KRP1B61
KRP2A61
KRP4AA51
KRCS01-1B

Note 2, 3

KRP1BA97

FXHQ-MA

BRC4C62
BRC7EA63W
BRC1E62 Note 7
KRP1B61
KRP2A61
KRP4AA51

DTA104A61

DTA104A61

DTA104A61

DTA114A61

BRC4C65

BRC2C51
BRC3A61
KRP1B56
KRP2A53
KRP4A54
KRCS01-1B
Note 4, 6

KRP1B96
KRP1BA101
DTA104A61 DTA104A61 DTA104A53

FXMQ-MA

KRP4A96

KRP4A91

Note 2, 3

FXDQ-PB
FXDQ-NB

FXAQ-P
BRC7EA618

KRP1BA54

KRP2A62
KRP2A61
KRP4AA52 KRP4AA51
KRCS01-1B
Note 3

KRP1CA93

Note 2, 3

KRP4AA93

DTA104A62 DTA104A61

DTA114A61

FXLQ-MA
FXNQ-MA
BRC4C62

BRC2C51
BRC3A61
KRP1B61
KRP2A61
KRP4AA51

DTA104A61

No.

Item

Model No.

Residential central remote controller

Central remote controller

Up to 16 groups of indoor units (128 units) can be easily controlled using the
large LCD panel. ON/OFF, temperature settings and scheduling can be controlled
individually for indoor units.
DCS302CA61 Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneKJB311AA
ously. Connectable up to 2 controllers in one system.
DCS301BA61 Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or
KJB212AA
simultaneously, and operation and malfunction can be displayed. Can be used in
combination with up to 8 controllers.
KEK26-1A
Programmed time weekly schedule can be controlled by unied control for up to
DST301BA61
64 groups of indoor units (128 units). Can turn units ON/OFF twice per day.
Note 2

DCS303A51

2-1

Electrical box with earth terminal (3 blocks)

3
3-1
3-2

Unied ON/OFF controller


Electrical box with earth terminal (2 blocks)
Noise lter (for electromagnetic interface use only)

Function

Schedule timer

For C(F)DK(X)S,
KRP928BB2S
FTK(X)S, FVXS, FLXS
Adaptors required to connect products other than those of the VRV System to the
For FCQ-B, FFQ-B,
DTA112BA51 high-speed DIII-NET communication system adopted for the VRV System.
FHQ-BV, FBQ-B
* To use any of the above optional controllers, an appropriate adaptor must be
installed on the product unit to be controlled.
Central control adaptor kit For UAT(Y)-K(A),FD-K DTA107A55

Wiring adaptor for other air-conditioner

DIII-NET
Expander Adaptor

9-1

Fixing Plate for


DNET Expander
Adaptor

5
6

Interface adaptor for


residential indoor units
Interface adaptor for
SkyAir-series

DTA103A51
Up to 1024 units can be centrally controlled in 64 different groups.
Wiring restrictions (max. length: 1,000m, total wiring length: 2,000m, max. number of branches: 16) apply to each adaptor.

DTA109A51
For GYAQ8,10,13,16,
20,25ANV1
For GYAQ30ANV1,
GYEQ20,30AN

AGDTA109E1
COB850J

The fixing plate is required when using D-NET Expander Adaptor.

Note: 1. Installation box for adaptor must be obtained locally.


2. For residential use only. Cannot be used with other centralised control equipment.

Notes: 1. Installation box is necessary for each adaptor marked .


2. Up to 2 adaptors can be xed for each installation box.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 installation boxes can be installed for each indoor unit.
5. Installation box is necessary for second adaptor.
6. Installation box is necessary for each adaptor.
7. Individual airow direction, auto airow rate and sensing sensor control can be set only via wired remote controller BRC1E62. Cannot be set via other remote controllers.

Building Management System


No.
1
1-1

Item
intelligent Touch
Controller

Basic
Option

intelligent Touch
Hardware
Controller
DIII-NET plus
Hardware
adaptor

Model No.
DCS601C51
DCS601A52

Additional 64 groups (10 outdoor units) is possible.

1-2

Electrical box with earth terminal (4 blocks)


Basic

Hardware

intelligent Touch
Manager

KJB411A

DCM601A51

Option

Hardware iTM plus adaptor

DCM601A52

2-1

intelligent Touch
Manager

2-2
2-3
2-4

Di unit

3
3-1
3-2

Communication
interface

4
5

DEC101A51

Dio unit

Contact/analogue signal

Function

Air-Conditioning management system that can be controlled by a


compact all-in-one unit.

DEC102A51
*1 Interface for use in BACnet

DMS502B51

Optional DIII board

DAM411B51

Optional Di board

DAM412B51

*2 Interface for use in LONWORKS

DMS504B51

Unication adaptor for computerised


control

DCS302A52

Wall embedded switch box.

Air-conditioning management system that can be controlled by touch


screen.
Additional 64 groups (10 outdoor units) is possible.
Max. 7 iTM plus adaptors can be connected to intelligent Touch
Manager.
8 pairs based on a pair of ON/OFF input and abnormality input.

Control Systems

For indoor unit use

System Conguration

4 pairs based on a pair of ON/OFF input and abnormality input.

Interface unit to allow communications between VRV and BMS.


Operation and monitoring of air-conditioning systems through BACnet
communication.

Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET


communication ports. Not usable independently.

Expansion kit, installed on DMS502B51, to provide 16 more wattmeter


pulse input points. Not usable independently.

Interface unit to allow communications between VRV and BMS.


Operation and monitoring of air-conditioning systems through
LonWorks communication.

Interface between the central monitoring board and central control


units.

Notes: *1. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
*2. LonWorks is a trademark of Echelon Corporation registered in the United States and other countries.
*3. Installation box for adaptor must be obtained locally.

03
55

04
56

Air Treatment Equipment Lineup


For Heat Pump series outdoor units only

Combine fresh air treatment and air conditioning,supplied from a single system.
Lineup
Model Name FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1
Capacity Index
125
200
250

Fresh air treatment and air conditioning


can be achieved with a single system by
using heat pump technologywithout the
usual troublesome air supply and air
discharge balance design. Fan coil units
for air conditioning and an outdoor-air
processing unit can be connected to the
same refrigerant line. The results are
enhanced design flexibility and a significant
reduction in total system costs.

* The system can operate with outdoor-air temperatures ranging


from -5 to 43. Heating performance is somewhat adversely
affected when the outdoor-air temperature is 0 or below.
* When shipped from the factory, the thermostat is set at 18
for cooling and 25 for heating. The set temperature can be varied
within the range of 1325 during cooling operation, and 1830
during heating operation, in the local setting mode using
the wired remote controller. The temperature, however, is not
displayed on the remote controller.
* While in machine protection mode and depending on outdoor air
conditions, discharge air temperature may not be at the set
temperature.
* The fan stops when operating in defrosting, oil returning and hot
start operations. The fan also may stop due to mechanical protection
control.

Ceiling mounted duct units with three differing


capacities are available. These can be connected
to GHP outdoor units to meet a variety
of different requirements.

Combination with GHP

Airflow rate

Air conditioning and outdoor air processing can be accomplished using a single system.

Optional equipment includes long-life filters.

Air
Conditioning

Outdoor
Air Supply

Heating
Supported
Range
Operation
5

Connection Conditions

The following restrictions must be observed in order to maintain the indoor units connected to the same system.

GHP heat recovery series outdoor unit can not be connected.

When outdoor-air processing units are connected to GHP heat pump series 8-25 class outdoor unit, the total connection capacity index must be 50% to 100% of the capacity
index of the outdoor units. When outdoor-air processing units are connected to GHP heat pump series 30 class outdoor unit, the total connection capacity index must be 80%
to 108% of the capacity index of the outdoor unit.
When outdoor-air processing units and standard indoor units are connected to GHP heat pump series 8-25 class outdoor unit, the total connection capacity index of the
outdoor-air processing units must not exceed 30% of the capacity index of the outdoor units.
A mixed combination of outdoor-air processing units and standard indoor units can not be connected to GHP heat pump series 30 class outdoor unit.

57

Supported Cooling
Operation Range

td

Ou

ur

at

r
pe
m
Te )
ir WB
A
or (C

Indoor Unit

90

Indoor Unit

10
0%
H R
Re umi elat
lat dity ive
ive
Hu
m
idi 32
ty

Usage Limitations

Outdoor-Air Processing Unit

Fan
Operation

15

19

30%

ve
elati

idity

Hum

(33.5)

* Group control is not possible between


this unit and standard type indoor
units. Connect remote controllers to
each unit.

BRC1E62
Nav Ease
(Wired remote controller)
(option)

The self-diagnosis function indicates the occurrence and nature of abnormalities in the system
by displaying codes on the remote controller.

* It is not possible to change the


discharge air temperature settings
from the central control system.
* Do not associate this equipment
into zones with standard indoor units,
as central control will not be possible.

Compatible with outdoor temperatures from -5 to


43.

GHP Heat Pump series outdoor units

As with the GHP system,


a variety of control systems
can be deployed, including
remote control from distances
of up to 500 m.

A central control system


compatible with the GHP
can be installed.

1,080 m3/h
1,680 m3/h
2,100 m3/h

FXMQ125MFV1
FXMQ200MFV1
FXMQ250MFV1

Outdoor-air processing units can be used without indoor units.

High-performance filters with dust collection


efficiencies (JIS calorimetry) of 90% and 65% are
also available as options.

The unit introduces outdoor air and adjusts


the outdoor air temperature via fixed discharge
temperature control, thereby reducing the air
conditioning load.

e
lativ
Re ity
20% umid
H

43

Notes:
1. The data shown in the graph illustrates the supported operation ranges under
the following conditions.
Indoor and Outdoor Unit
Effective piping length: 7.5 m
Height differential: 0 m
2. The discharge temperature can be set using the remote controller. However,
the actual temperature may not match the temperature setting under some
circumstances due to the outdoor-air processing load or mechanical protection
controls.
3. The system will not operate in fan mode when the outdoor air temperature is
5 or below.

DCS302CA61
Central remote controller
(option)

As with the GHP, the equipment employs the super


wiring system so that the wiring linking indoor and
outdoor units can also be utilised for central control.
Notes:
* Linked control of the product and the Heat Reclaim Ventilator is
not supported.
* This equipment is intended for the treatment of outdoor air only.
It is not to be used for maintaining indoor air temperature. Install
and use with standard indoor units. Be sure to position the air
discharge openings of the product in positions where the airflow
will not blow on people directly. When outdoor-air processing is
in excess, the unit switches to thermo-off mode, and outdoor air
flows into the room directly.
* For outdoor ducts, be sure to provide heat insulation to prevent
condensation.
* Group control of the product and the standard indoor units is not
supported. A separate remote controller should be connected to
each individual unit.
* The system will not operate in fan mode when the outdoor air
temperature is 5 or below.
* If the product is allowed to operate 24 hours a day, maintenance
(part replacement, etc.) must be performed periodically.
* Temperature setting and Power Proportional Distribution (PPD)
are not possible even if the intelligent Touch Controller or the
intelligent Touch Manager is installed.
* The remote controller wired to the outdoor-air processing unit
must not be set as the master remote controller. Otherwise,
when set to Auto, the operation mode will switch according to
the outdoor air conditions, regardless of the indoor temperature.

Air Treatment
Equipment Lineup

Outdoor-Air Processing Unit

58

Air Treatment Equipment Lineup


Standard Specifications

Dimensions

Indoor unit

FXMQ125/200/250MFV1

28.0

kcal/h

7,700

12,000

15,000

Btu/h

30,400

47,400

59,400

8.9

13.9

17.4

0.548

0.638

Galvanised steel plate

Airflow rate
External static pressure

470X744X1,100

470X1,380X1,100

kW
/s

300

466

583

Pa

225

275

255

m3/min
240 V

0.380
18

28

Air filter

35

*2
Liquid

mm

Gas

mm

Drain

mm

Machine weight
Sound level *3

240 V

9.5 (flare)
15.9 (flare)

Range of the discharge


temperature *5

22.2 (brazing)

kg

86

123

dB(A)

43

48
8 class and above

Cooling

19 to 43
-5 to 15

Cooling

13 to 25

Heating

18 to 30

*4. Only Heat Pump series outdoor units can be connected. Refer to page 57 for connection
condition details.
*5. Local setting mode. Not displayed on the remote controller.
This equipment cannot be incorporated into the remote group control of the GHP system.

FXMQ200/250MFV1

11X100=1100
1200
1230

30

1
2
3
4
5
6

Liquid pipe connection


Gas pipe connection
Drain piping connection
Electric parts box
Ground terminal
Name plate

7
8
9
10
11
12

Power supply wiring connection


Transmission wiring connection
Hanger bracket
Discharge companion flange
Water supply port
Attached piping (Note. 1)

12

61

20- 7 hole
(All around)

5X100=500
600
630

30

A View

DST301BA61

Wiring adaptor for electrical appendices (1)

KRP4AA51
KAFJ371L140

KAFJ371L280

KAFJ372L140

KAFJ372L280

KAFJ373L140

KAFJ373L280

KDJ3705L140

KDJ3705L280

Drain pump kit


Adaptor for wiring
Notes: *1. Filter chamber has a suction-type flange. (Main unit does not.)
Dimensions and weight of the equipment may vary depending on the options used.
Some options may not be usable due to the equipment installation conditions, so please
confirm prior to ordering.

KDU30L250VE
KRP1B61
Some options may not be used in combination.
Operating sound may increase somewhat depending on the options used.

200

346

360

330

200

1230

B View (For FXMQ200MFV1)


1004

360

Colourimetric method 90%

16-M5 hole
(All around)

KRP2A61

Wiring adaptor for electrical appendices (2)

5X200=1000

16-M5 hole
(All around)

10-M5 hole
(All around)

2X200=400
580
630

B View

Air Treatment
Equipment Lineup

DCS301BA61

Schedule timer

250

Unified ON/OFF controller

200

DCS302CA61

360

BRC1E62

Central remote controller

Colourimetric method 65%

FXMQ250MFV1
250

Operation remote controller

FXMQ200MFV1

330

FXMQ125MFV1

250

Operation/control

D
20- 4.7 hole
32- 4.7 hole
32- 4.7 hole

FXMQ125MFV1
245
60

32- 7 hole
(All around)

C
5X100=500
11X100=1100
11X100=1100

580

Long-life replacement filter


Filters

613
760

B
685
1296
1296

Notes:
1. The attached piping in the diagram is for FXMQ200MFV1 and
FXMQ250MFV1 only. The gas piping connection port ( 2 in the
diagram) has a different bore form with FXMQ125MFV1.
2. An air filter is not supplied with this unit. Be sure to mount an air
filter in the suction side.[Use a filter with dust collection efficiency of
at least 50% (gravimetric method). This is available as an option.]
3. For outdoor ducts, be sure to provide heat insulation to prevent
condensation.

A View

Model

59

Suction side (Note.2)

B View

Indoor unit

Filter chamber *1

*These diagrams are based on FXMQ200 and FXMQ250MFV1.

Options

High-efficiency
filter

2 11 6 4

30

1100

250

Notes: *1. Specifications are based on the following conditions;


Cooling: Outdoor temp. of 33CDB, 28CWB (68% RH), and discharge temp. of 18CDB.
Heating: Outdoor temp. of 0CDB, -2.9CWB (50% RH), and discharge temp. of 25CDB.
Equivalent reference piping length: 7.5 m (0 m horizontal)
*2. An intake filter is not supplied, so be sure to install the optional long-life filter or high-efficiency filter.
Please mount it in the duct system of the suction side. Select a dust collection efficiency (gravity method)
of 50% or more.
*3. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
These values are normally somewhat higher during actual operation as a result of ambient conditions.

A View

10 class and above

Heating

Discharge side

PS1B female thread

Connectable outdoor units *4


Operation range
(Fan mode operation between 15 and 19C)

19.1 (brazing)

1100 or more
(Service space)

Inspection hole 600 or more

390

Motor output

470

mm

Dimensions (HxWxD)

D
(All around)

296

0.359

50

kW

Casing

25

Power consumption

Table of dimensions
Model
A
FXMQ125MFV1 744
FXMQ200MFV1 1380
FXMQ250MFV1 1380

3X100=300

kW

360
330
3X100=300

Heating capacity *1

390

22.4

296

95,500

14.0

kW

76,400

24,100

47,800

Approx.
150

19,300

Btu/h

Liquid piping diameter


9.5
9.5
9.5

12,000

650 or more
(Service space)

kcal/h

Gas piping diameter


15.9
19.1 attached piping
22.2 attached piping

Model
FXMQ125MFV1
FXMQ200MFV1
FXMQ250MFV1

1-phase 220 - 240 V (also required for indoor units), 50 Hz

Cooling capacity *1

Refrigerant
piping

FXMQ250MFV1

25

Power supply

FXMQ200MFV1

360
330

FXMQ125MFV1

Local connection piping size

1148

3X100=300

Model

Fan

9
10

Ceiling Mounted Duct Type

250

Type

5X200=1000
1230

B View (For FXMQ250MFV1)

60

Air Treatment Equipment Lineup


Heat Reclaim Ventilator VAM series
Air conditioning load reduced by approximately 31%!

23%

Total heat exchange ventilation

Model Names

VAM150GJVE, VAM250GJVE, VAM350GJVE,


VAM500GJVE, VAM650GJVE, VAM800GJVE,
VAM1000GJVE, VAM1500GJVE, VAM2000GJVE
Heat Reclaim Ventilator remote controller*
BRC301B61 (Option)

Improved Enthalpy Efficiency


2
Higher External Static Pressure
Enhanced Energy Saving Functions
1

* This remote controller is used in case of independent


operation of Heat Reclaim Ventilator.

This VAM series provides higher enthalpy efficiency 1, due to the greatly enhanced performance of the thin film
element. Furthermore, improved external static pressure 2 offers more flexibility for installation. Along with these three
outstanding improvements, the nighttime free cooling operation contributes to energy conservation and more
comfortable space.
EA

(Exhaust air to outdoors)

For models: VAM150/250/350/650/800/1000/2000GJVE


2 For models: VAM150/350/500GJVE
1

Due to the thinner film

Decreases the moisture resistance of the partition sheets drastically.


Realises more space for extra layers in the element,
Thickness of
resulting in increased effective area that supply and
the partition sheet
exhaust air can be exposed to.

Moisture absorption increased by approx. 10%!


Indoor

Sheet structure

Outdoor

High-humidity air

Molecule of water
Miscellaneous gas
CO2 molecule, etc.

Exhaust air

(Fresh air from


outdoors)

Reduces air conditioning load by


not running the Heat Reclaim
Ventilator while air is still clean
soon after the air conditioner is
turned ON.

Precise, thin-film
material

RA
(unclean
indoor air)

Outdoor air
(fresh air)

Supply air

2%

Pre-cool,
Pre-heat Control

Exhaust air

RA

(Return air
from room)

Automatically switches the


ventilation mode (Total Heat
Exchange Mode/Bypass Mode)
according to the operating status
of the air conditioner.

Enthalpy efficiency drastically improved by employing


thin film element! (VAM-GJ model)

SA

OA

6%

Auto-ventilation Mode
Changeover Switching

This unit recovers heat energy lost through ventilation and


curbs room temperature changes caused by ventilation, thereby
conserving energy and reducing the load on the air conditioning
system.

Low-humidity air

Moisture exchange efficiency is greatly improved by using optimised


thinner films and moisture-absorption materials in the element.
Furthermore, miscellaneous gas barrier properties are maintained by
decreasing the porosity in the moisture-absorption materials.

31%

(Supply air
to room)

Daikin air conditioner

The air conditioning load reduction values are based on the following conditions;
Application: Tokyo office building
Building form: 6 floors above ground, 2 floors underground, floor area 2,100 m2
Personnel density: 0.25 person/m2
Ventilation volume: 25 m3/h
Indoor air conditioning level: summer 25 50% RH, intermediate seasons 24 50%
RH, winter 22 40% RH
Operating time: 2745 hours (9 hours per day, approx. 25 days per month)
Calculation method: simulation based on "MICRO-HASP/1982" of the Japan
Building Mechanical and Electrical Engineers Association.

Indoor unit

ON/OFF signal
Cooling/Heating mode signal
Set temperature signal
Ventilation signal

Operating mode signal


Filter cleaning signal
Failure detection signal

Interlocking

61

Heat Reclaim
Ventilator

Compact Equipment

Energy Conservation

With a height of just 306 mm, the unit easily fits in limited
spaces, such as above ceilings.

Air conditioning load reduced by approximately 31%!

* For VAM500GJVE

Air Conditioning Load


Reduced by Approximately

20%

0%
Normal
ventilation fan

Nighttime free cooling operation*1

LCD remote controller


for indoor unit

306 mm

The air conditioning load reduction values may vary according to weather and
other environmental conditions at the location of the machine's installation.

Air conditioning load reduction (%)

SA

Standard operation at
temperatures down to -15.

-15CDB

-20

-10

50CDB

10

20

30

40

50

VAM-GJ
Interlocked operation
with air conditioner

Air conditioning sensible

heat load reduced by


Nighttime free cooling operation is an energy-conserving function that works at night when air
*2
conditioners are off. By ventilating rooms containing office equipment that raises the room
approx.
temperature, nighttime free cooling operation reduces the The indoor accumulated heat is discharged at night.
cooling load when air conditioners are turned on in the
This reduces the air conditioning load the next day thereby increasing efficiency.
morning. It also alleviates feelings of discomfort in the
morning caused by heat accumulated during the night.

5% !

Nighttime free cooling operation only works to cool and if connected to


Building Multi or VRV systems.
Nighttime free cooling operation is set to off in the factory settings, so if
you wish to use it, request your dealer to turn it on.

Cold Climate Compatible

VAM-GJ
Individual operation

*1 This function can be operated only when interlocked with air conditioners.
*2 Value is based on the following conditions:
Cooling operation performed from April to October.
Calculated for air conditioning sensible heat load only
(latent heat load not included).

Cold air

Exhaust
heat

Generated
heat

Heat is discharged.

Indoor
unit

Exhaust
heat

Indoor
unit

Air Treatment
Equipment Lineup

The Heat Reclaim Ventilator Creates a High-Quality Environment by Interlocking


with the Air Conditioner

Comfortable!

The load is small so the temperature is rapidly reduced


to a comfortable level.
*Interlocked operation with an air conditioner

62

Air Treatment Equipment Lineup


Specifications

1-phase, 220-240 V/220 V, 50 Hz/60 Hz


%

High
Low

For Heating Ultra-High

High
Low
For Cooling Ultra-High

High
Low
Power
Consumption

Heat
Ultra-High
Exchange
High
Mode

Low
Bypass
Mode

Sound
Level

79

74

75

72

78

72

77

75

79

74

75

72

78

72

77

84

79

82

80

77

74

80.5

75.5

79

72

71

70

67

67.5

65

70

65

72

72

71

70

67

67.5

65

70

65

72

76

74

77

74

71.5

67.5

72.5

67

75

66

63

66

55

61

61

64

61

62

66

63

66

55

61

61

64

61

62

70

66

70

59

64

64

68.5

64

66

125

137

200

248

342

599

635

1,145

1,289

111

120

182

225

300

517

567

991

1,151

57

60

122

128

196

435

476

835

966

125

137

200

248

342

599

635

1,145

1,289

High

111

120

182

225

300

517

567

991

1,151

Low

57

60

122

128

196

435

476

835

966

27-28.5

27-29

31.5-33

33-35.5

34-36

39-40.5

39.5-41.5

39.5-41.5

41.5-43.5

26-27.5

26-27.5

30-31.5

31.5-34

33-34.5

37-39.5

37.5-39.5

37.5-39.5

39-43

20.5-21.5

21-22

23-25

25-28.5

27.5-29.5

35-37.5

35-37.5

35-37.5

36-39

28.5-29.5

28.5-30.5

33-34.5

34.5-36

35-37.5

40.5-42

40.5-42.5

41-43

43-45.5

High

27.5-28.5

27.5-29

31.5-33

33-34.5

33-35.5

38.5-40

38.5-40.5

39.5-41

40.5-45

Low

22.5-23.5

22.5-23

24.5-26.5

25.5-28.5

27.5-30.5

36-38.5

36-38.5

36.5-38

37.5-39.5

Ultra-High

Heat
Ultra-High dB(A)
Exchange
High
Mode
Low
Bypass
Mode

75

79

Ultra-High dB(A)

Casing

Galvanised steel plate

Insulation Material

Self-extinguishable polyurethane foam

Dimensions (HXWXD)
Machine Weigh

mm

278X810X551

kg

24

Heat Exchange System

306X879X800

338X973X832

32

45

External Static
Pressure

129

Ultra-High m3/h

150

250

350

500

650

800

1,000

1,500

2,000

High

150

250

350

500

650

800

1,000

1,500

2,000

Low

100

155

230

320

500

700

860

1,320

1,720

Ultra-High

41

69

97

138

180

222

277

416

555

High

/s

41

69

97

138

180

222

277

416

555

Low

27

43

63

88

138

194

238

366

477

120

70

169

105

85

133

168

112

116

High

106

54

141

66

53

92

110

73

58

Low

56

24

67

32

35

72

85

56

Ultra-High Pa

Motor Output

kW

Connection Duct Diameter

mm

0.030X2
100

0.090X2
150

0.140X2
200

0.280X2
250

45

Silencer (Option)
Duct
(Obtain locally)
Thermal insulation material (Obtain locally)

Option List
Type
Item
Heat Reclaim Ventilator remote controller
Residential central remote controller
Centralised Central remote controller
controlling
Unified ON/OFF controller
device
Schedule timer
Wiring adaptor for electrical
appendices
For humidifier
Installation box for adaptor PCB
For heater control kit

Notes: 1.
2.
3.
4.

OA

EA

BRC301B61
DCS303A51 *1
DCS302CA61
DCS301BA61
DST301BA61
KRP2A61
KRP50-2
KRP50-2A90 (Mounted electric component assy of Heat Reclaim Ventilator)
BRP4A50

FXFQ-S
FXDQ-PB
FXLQ-MA
Type
For wiring (indoor unit of GHP) FXFQ-P FXZQ-M FXUQ-A FXCQ-M FXKQ-MA FXDQ-NB FXSYQ-M FXDYQ-M(A) FXMQ-P FXMQ-MA FXHQ-MA FXAQ-P FXNQ-MA
Installation box for adaptor PCB

Sirocco fan

Unit Ambient Condition

KRP1C63 KRP1BA57 KRP1C67 KRP1B61 KRP1B61 KRP1B56


KRP1B61
Notes 2, 3 Note 4, 6
Notes 2, 3 Notes 4, 6 Notes 5

KRP1H98 KRP1BA101
KRP1B96
KRP1BA101 KRP4A91

Installation box is necessary for each adaptor marked .


Up to 2 adaptors can be fixed for each installation box.
Only one installation box can be installed for each indoor unit.
Up to 2 installation boxes can be installed for each indoor unit.

KRP1C64 KRP1B61 KRP1BA54 KRP1B61


Notes 2, 3
Notes 2, 3
Note 3

KRP4A96
KRP1CA93 KRP4AA93

5. Installation box is necessary for second adaptor.


6. Installation box is necessary for each adaptor.
7. *1 For residential use only. When connected with a Heat Reclaim Ventilator (VAM), you can
only switch the power ON/OFF. Cannot be used with other centralised control equipment.

Type VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE VAM2000GJVE

KDDM24B50
KDDM24B100
KDDM24B100X2
Nominal pipe diameter mm

200
250
High efficiency filter
KAF242H25M
KAF242H50M
KAF242H65M KAF242H80M KAF242H100M KAF242H80MX2 KAF242H100MX2
Air filter for replacement
KAF241G25M
KAF241G50M
KAF241G65M KAF241G80M KAF241G100M KAF241G80MX2 KAF241G100MX2
Flexible duct (1 m)
K-FDS101D
K-FDS151D
K-FDS201D
K-FDS251D
Flexible duct (2 m)
K-FDS102D
K-FDS152D
K-FDS202D
K-FDS252D
Duct adaptor

YDFA25A1
Nominal pipe diameter mm

250

Item

Silencer

0.280X4
350

-1550DB, 80%RH or less

Notes: 1. Sound level is measured at 1.5 m below the centre of the body.
2. Airflow rate can be changed over to Low mode or High mode.
3. Sound level is measured in an anechoic chamber.
Sound level generally becomes greater than this value depending on the operating conditions, reflected sound, and peripheral noise.
4. The sound level at the air discharge port is about 8 dB(A) higher than the unit's sound level.
5. The specifications, designs and information given here are subject to change without notice.
6. Temperature Exchange Efficiency is the mean value between cooling and heating.
7. Efficiency is measured under the following conditions:
Ratio of rated external static pressure has been maintained as follows; outdoor side to indoor side = 7 to 1.
8. In conformance with JIS standards (JIS B 8628), operating sound level is based on the value when one unit is operated, with the value converted for an anechoic chamber. This is transmission
sound from the main unit, and does not include sound from the discharge grille. Thus it is normal for the sound to be louder than the indicated value when the unit is actually installed.
9. Sound level from the discharge port causes the value to be approximately 8 dB(A) (models with the airflow rate of less than 150 to 500 m3/h) to approximately 11 dB(A) (models with
the airflow rate of 650 m3/h or more) greater than the indicated value. Furthermore, fan rotation and noise from the discharge grille may increase depending on the on-site duct
resistance conditions. Please consider noise countermeasures when installing the unit.
10. With large models in particular (1500 and 2000 m3/h models), if the supply air (SA) grille is installed near the main unit, the noise of the main unit may be heard from the discharge
grille via the duct, and this will result in a marked increase in noise. In such cases, if peripheral effects are included (such as reverberation of the floor and walls, combination with
other equipment, and background noise), sound level may be as much as 15 dB(A) higher than the indicated value. When installing a large model, please provide as much separation
as possible between the main unit and the discharge grille. If the equipment and discharge grille are near each other, please consider countermeasures such as the following:
Use a sound-muffling box, flexible duct and sound-muffling air supply/discharge grilles
Decentralised installation of discharge grilles
11. When installing in a location with particularly low background noise such as a classroom, please consider the following measures to avoid transmission sound from the main unit:
Use of ceiling materials with high sound insulating properties (high transmission loss)
Methods of blocking sound transmission, for example, by adding sound insulating materials around the bottom of the sound source.
Alternatively, consider supplementary methods such as installing the equipment in a different location (corridor, etc.)

63

SA

157

Multidirectional fibrous fleeces

Type

Airflow Rate

67

Specially processed nonflammable paper

Air Filter
Airflow Rate

55

Round hood
(Obtain locally)

Branch duct
(Obtain locally)

Air to air cross flow total heat (Sensible heat + latent heat) exchange

Heat Exchange Element Material


Fan

387X1,111X832 387X1,111X1,214 785X1,619X832 785X1,619X1,214

High efficient filter


(Option)

SA

Additional
function

Enthalpy
Exchange
Efficiency

79

Controlling device

Ultra-High

Flexible duct
(Option)

RA

PC Board Adaptor

Power Supply
Temp. Exchange
Efficiency

Air suction/discharge grille (Obtain locally)

VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE VAM2000GJVE

PC board adaptor for heater control kit (BRP4A50)


When the installation of an electric heater is required in a cold region, this adaptor with an internal timer function eliminates the
complicated timer connecting work that was necessary with conventional heaters.
Indoor
RA

EA

Heat Reclaim Ventilator

SA
BRP4A50
Thermostat (Obtain locally)
(OFF when the temperature is at or more
than 5)

Outdoor

Heater
(Obtain locally)

OA
Thermostat
(Obtain locally)
(ON when the temperature
is at or below -10)
Power supply (Obtain locally)
Relay box

Notes when installing


Examine fully an installation place and specification for
using the electric heater based on the standard and
regulation of each country.

Supply the electric heater and safety production devices


such as a relay and a thermostat, etc of which qualities
satisfy the standard and regulation of each country at site.
Use a non-inflammable connecting duct to the electric
heater. Be sure to allow 2 m or more between the electric
heater and the Heat Reclaim Ventilator for safety.

Air Treatment
Equipment Lineup

MODEL

Options

For the Heat Reclaim Ventilator, use a different power


supply from that of the electric heater and install a circuit
breaker for each.

64

Memo