DAIKIN
GAS
HEAT PUMP
AIR CONDITIONING SYSTEM
Lower CO 2 Emission
Natural gas is used as the main energy
source. Natural gas emissions are
comparatively lower than other fossil fuels.
CO2 emissions
100
80
Coal
60
Natural gas
Petroleum
What is GHP ?
The compressor is the heart of an
air conditioner and consumes
the most energy. In a Gas Heat Pump (GHP)
air conditioner, the compressor is
driven by a gas engine using natural gas,
whereas an Electric Heat Pump (EHP)
uses an electric motor.
Indoor Unit
Image of
heating
Power consumption
100
Fans
10
Heat
exchanger
E HP
Compressor
GHP
Gas
Electricity
As the load changes during the day, GHP systems are able to match the varying load
by adjusting compressor capacity output through engine speed control.
GHP
EHP
Time
Heating capacity
01
Outdoor Unit
Room temperature
Gas engine
GHP
EHP
10C
02
Footprint 1.46 m2
16-25 class
Centralised control
Footprint 1.23 m2
8-13 class
By controlling both EHP and GHP systems off a common centralised control system,
the designer can capitalize on the unique characteristic and features of both
systems to deliver an engineered solution that meets the demands of the modern building.
Weight : 565 kg
13 class series
Control is centralised
by one controller.
D
Weight : 745 kg
-NET communication
20 class series
-NET communication
VRV System
GHP System
SYSTEM
(Electric Heat Pump)
Footprint 1.35 m2
20 class
Footprint 1.68 m2
30 class
Control Systems
Footprint 1.68 m2
30 class
Capacity range
Heat pump
standard series
Heat pump
large-capacity series
Heat recovery series
03
22.4 kW
28.0 kW
35.5 kW
45.0 kW
56.0 kW
71.0 kW
85.0 kW
8 class
10 class
13 class
16 class
20 class
25 class
30 class
Common models of indoor units
Common indoor models for both GHP and EHP systems ensure
a consistent look for exposed units whilst maintaining similar
comfort levels and keeping operational control.
Air Treatment
Equipment Lineup
04
Installation Flexibility
8 / 10 / 13
class series
The long piping length provides more design flexibility, to meet the needs of large commercial buildings.
16 / 20 / 25
class series
Weight :
565 kg
2,077
mm
Max. actual
piping length
20 class series
165 m
745 kg
2,077
mm
13 class series
Weight :
880 mm
880 mm
Max. equivalent
piping length
190 m
*1
520 m
1,400 mm
1,660 mm
Footprint 1.23 m
h
e
Footprint 1.46 m
(Unit: mm)
External static
pressure:
30 Pa
50 m
Outdoor unit below indoor unit:
40 m
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .
Actual
piping length
Example
Equivalent
piping length
165 m
a+f+g+h+i
190 m *1
520 m
a+b+c+d+e+f+g+h+i
Between the first indoor branch and the farthest indoor unit
60 m
f+g+h+i
Level
Difference
Example
15 m
50 m
40 m
*1
Elevator
Outdoor unit
Outdoor unit
8 / 10 / 13 class series
2,077
1,400
Maximum
allowable
piping length
Maintenance
space
Balcony
*1. Field setting is necessary.
880
Maximum
allowable
level difference
Quiet Operation
Heating
Cooling
10C
10C
18C (WB)
43C
dB(A) 60
55
54
52
56
57
45
40
Easy Maintenance
10 class
13 class
05
Connection ratio
Maximum connection ratio is 130%.
Connection ratio
50%130%
Normal mode
Quiet mode
50
8 class
*1. When the equivalent piping length between outdoor and indoor units is 100 m or more, the size of main pipes (both gas-side and liquid-side) must be
increased.Refer to the Engineering Data Book.
59
54
Connection ratio =
kW
22.4
28.0
35.5
45.0
56.0
71.0
Class
8
10
13
16
20
25
Capacity
index
200
250
320
400
500
630
100%
200
250
320
400
500
630
130%
260
325
416
520
650
819
Maximum number of
connectable indoor units
13
16
20
26
33
41
06
Cooling operation
Model
GYAQ8ANV1
GYAQ10ANV1
Power supply
Gas
GYAQ13ANV1
Capacity
22.4
28.0
35.5
45.0
56.0
71.0
76,400
95,500
121,000
154,000
191,000
242,000
kcal/h
19,300
24,100
30,500
38,700
48,200
61,100
25.0
31.5
40.0
50.0
63.0
80.0
Btu/h
85,300
107,000
136,000
171,000
215,000
273,000
kcal/h
21,500
27,100
34,400
43,000
54,200
68,800
kW
2
2,077
2,077
2,077
2,077
2,077
2,077
mm
1,400
1,400
1,400
1,660
1,660
1,660
Depth
mm
880
880
880
880
880
880
Height
Cooling
Power
consumption
Heating
kW
0.34
0.44
0.57
1.26
1.26
1.53
kW
0.42
0.58
0.74
1.11
1.11
1.34
Cooling
Fuel gas
consumption Heating
kW
15.0
19.2
26.4
31.0
41.7
58.5
kW
15.9
20.3
27.0
32.7
42.0
57.2
Scrollx1
Scrollx1
Scrollx1
Scrollx2
Scrollx2
Scrollx2
Type
Type
Propeller fan
Number of units
Motor output
Airflow rate
m3/min
275x2
275x2
275x2
350+600
350+600
600x2
167
194
213
346
346
388
15.9
15.9
15.9
Drive
Refrigerant
Piping
Direct drive
Liquid
mm
Gas
9.5
9.5
mm
19.1
22.2
25.4
28.6
28.6
31.8
inch
R3/4
R3/4
R3/4
R3/4
R3/4
R3/4
mm
80
80
80
100
100
100
30
30
30
30
30
30
565
565
565
745
745
755
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
11.0
11.0
11.0
11.5
11.5
11.5
62
kg
Type
Charge
kg
14
-10
43
-10
10
20
30
OUTDOOR TEMPERATURE (CDB)
40
OPERATION
10
10
-30
-10
-20
-10
18
10
20
Options
Option name
Cool/Heat selector *1
Fixing box
Harness kit for Cool/Heat Selector *2
REFNET header
Model
GYAQ8ANV1
GYAQ10ANV1
GYAQ16ANV1
GYAQ20ANV1
GYAQ25ANV1
KRC19-26A
KJB111A
AGKRC19E1
KHRP26M22H (Max. 4 branch)
KHRP26M33H (Max. 8 branch)
KHRP26A22T
KHRP26A33T
KHRP26A22T
KHRP26A33T
KHRP26A72T
Distributive
piping
REFNET joint
GYAQ13ANV1
KHRP26M22H
KHRP26M33H
KHRP26M72H
KHRP26M73H
4
8
8
8
branch)
branch)
branch)
branch)
KHRP26A22T
KHRP26A33T
KHRP26A72T
KHRP26A73T
KHRP26M73TP
KHRP26M73HP
(Max.
(Max.
(Max.
(Max.
K-GBM13B70
AGFJ280E1
AGBJ280E1
K-GBM13B71
AGFJ560E2
AGBJ560E1
*1. The Cool/Heat Selector is required when selecting cool/heat mode from the outdoor unit.
*2. The harness kit is required when using the Cooling/Heating Selector.
*3. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.
The specified antivibration mount must be used. Otherwise abnormal vibration may occur.
*4. The Air direction adjuster is designed to prevent snow from accumulating on the air outlet of the outdoor unit and to change the air direction to the front or back if the air outlet is
blocked by an obstacle. If The Air direction adjuster is installed, the operation sound may increase slightly depending on ambient conditions.
Aisin Coolant S
Freezing temperature
-35
Normal mode
Sound
pressure level Quiet mode
dB(A)
54
56
59
56
59
dB(A)
52
54
57
54
57
60
Piping length;equivalent/actual
190/165
190/165
190/165
190/165
190/165
190/165
50
50
50
50
50
50
40
40
40
40
40
40
15
15
15
15
15
15
13
16
20
26
33
41
50-130
50-130
50-130
50-130
50-130
50-130
Note:
10
20
Type
07
12.7
Weight
Refrigerant
20
28
* If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit.
Dimensions Width
Fans
24
30
GYAQ25ANV1
Btu/h
Compressor
30
Natural gas
kW
Heating
GYAQ20ANV1
1- phase , 230 V , 50 Hz
Type
Cooling
GYAQ16ANV1
Heating operation
INDOOR TEMPERATURE (CDB)
Specifications
number
capacity
1 Indoor temp.: 27 CDB, 19CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m
2 Indoor temp.: 20 CDB / outdoor temp.: 7CDB, 6CWB/ Equivalent piping length: 7.5 m, level difference: 0 m
08
Installation flexibility
The long piping length provides more design flexibility, which can match even large-sized buildings.
1080 kg
2,170
mm
Max. actual
piping length
Footprint 1.68 m2
800 mm
Max. equivalent
piping length
170 m
200 m
640 m
2,100 mm
The compact outdoor unit can be installed on the service balcony of each floor.
External static
pressure:
Maintenance
space
21C
18C (WB)
Cooling
10C
46C
Quiet Operation
k
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .
dB(A) 65
60
Maximum
allowable
piping length
Maximum allowable
level difference
50 m
Actual
piping length
Balcony
*1
30 Pa
Outdoor unit
Example
Equivalent
piping length
170 m
a+f+g+h+i
200 m
640 m
a+b+c+d+e+f+g+h+i
Between the first indoor branch and the farthest indoor unit
90 m *1
f+g+h+i
Level
Difference
Example
15 m *1
50 m
*1.When the piping length between the indoor branch and the farthest indoor unit is 40 m or more, the maximum allowable level difference between the indoor
units is decreased.Refer to the Engineering Data Book.
62
59
55
Normal mode
Connection ratio
Quiet mode
Connection ratio
50%130%
50
45
30 class
Easy Maintenance
Frequent oil change is not required.
Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 20,000hrs of operation.
Connection ratio =
kW
85.0
Class
30
Capacity
index
750
100%
750
130%
975
Maximum number of
connectable indoor units
48
09
10
Operation range
GYAQ30ANV1
Power supply
Gas
1- phase , 230 V , 50 Hz
Type
1
Capacity
290,000
kcal/h
73,100
Btu/h
kcal/h
Casing colour (Munsell no.)
95.0
324,000
81,700
Ivory white(5Y7.5/1)
mm
2,170
Dimensions Width
mm
2,100
Depth
mm
800
Cooling
Power
consumption Heating
kW
1.66
kW
1.51
Cooling
Fuel gas
consumption Heating
kW
67.7
Height
Compressor
kW
66.3
Type
Scrollx2
Type
Propeller fan
Number of units
Fans
Motor output
Airflow rate
m3/min
Drive
570
Direct drive
mm
Gas
mm
31.8
inch
R3/4
mm
60.5
370x3
Liquid
Refrigerant
Piping
20
10
(Note 1)
14
-10
-10
46
10
20
30
OUTDOOR TEMPERATURE (CDB)
40
50
30
RANGE FOR CONTINUOUS OPERATION
20
15
-21
18
10
-30
-20
-10
10
20
85.0
Btu/h
kW
Heating
25
30
Natural gas
kW
Cooling
30
Model
Heating operation
INDOOR TEMPERATURE (CDB)
Cooling operation
kg
Type
19.1
Option name
Cool/Heat selector
Fixing box
REFNET header
Distributive
piping
REFNET joint
Pipe size reducer
Antivibration mount *1
Air direction adjuster
Air guard
Exhaust extension adaptor
Exhaust extension external drain filter
Water discharge kit
External contact output harness *2
Model
GYAQ30ANV1
KRC19-26A
KJB111A
KHRP26M22H
KHRP26M33H
KHRP26M72H
KHRP26M73H
(Max.
(Max.
(Max.
(Max.
4
8
8
8
branch)
branch)
branch)
branch)
KHRP26A22T
KHRP26A33T
KHRP26A72T
KHRP26A73T
KHRP26M73TP , KHRP26M73HP
YGAS850J1
FKA850H
ARD850H
HA850H
DFB19E
RGA850H1
OSH850J
*1. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.
The specified antivibration mount must be used. Otherwise abnormal vibration may occur.
*2. Only use of input contact point is possible. Use of output contact point is not possible. (only for 30 class heat pump)
15
1080
R-410A
Charge
kg
11.8
Yanmar genuine GHP oil
Engine
coolant
Type
Sound
pressure level
Normal mode
dB(A)
Quiet mode
dB(A)
Freezing temperature
Piping length;equivalent/actual
-35
62
59
200/170
50
15
Options
number
capacity
50
48
50-130
Note:
1 Indoor temp.: 27 CDB, 19 CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m
2 Indoor temp.: 20 CDB / outdoor temp.: 7CDB, 6CWB/ Equivalent piping length: 7.5 m, level difference: 0 m
11
12
BS unit
Indoor unit
(Heating)
800 mm
Indoor unit
(Cooling)
1,690 mm
BS
Unit
Heat radiation
cooling
cooling
cooling
Indoor Unit
For example,
the heat recovery system can
meet the following needs:
2,100 mm
Footprint 1.35 m2
Outdoor Unit
1040 kg
2,170
mm
800 mm
(A)
Weight :
860 kg
2,170
mm
BS unit
30 class
series
Weight :
BS unit
20 class
series
Footprint 1.68 m2
The compact outdoor unit can be installed on the balcony of each floor.
cooling
External static
pressure:
(B)
cooling,
( mainly
part heating operation )
Heat radiation
In mainly cooling, partly heating mode, the system recycles heat exhausted from the cooling operation to use for heating.
In mainly heating, partly cooling mode, the system uses cooled post-heating operation refrigerant for cooling. Efficiency
improves when simultaneous operation is performed.
Heating
Window
cooling
cooling
cooling
Cooling
Cooling
BS unit
*1
heating
30 Pa
Outdoor unit
(C)
Maintenance
space
Balcony
*1. Field setting is necessary.
cooling
cooling
heating
heating
(D)
Heat absorption
Cooling
Heating
heating,
( mainly
part cooling operation )
BS unit
cooling
heating
heating
Hallway
heating
Quiet Operation
(E)
heating
heating
heating
heating
Heating
11C
18C (WB)
Cooling
10C
43C
Note: Operation modes (A) and (E) are applicable when the outdoor temperature is 35C and 7C respectively;
The other modes are applicable under typical outdoor conditions.
dB(A) 65
60
55
62
58
59
55
Normal mode
Quiet mode
50
13
45
20 class
30 class
Easy Maintenance
Heating
Cooling
14
Specifications
Max. equivalent
piping length
170 m
200 m
640 m
First indoor branch
f
b
Model
h
d
GYEQ20AN
Power supply
Gas
Natural gas
Type
kW
Cooling
Capacity
50 m
56.0
85.0
Btu/h
191,000
290,000
kcal/h
48,200
73,100
kW
Heating
63.0
95.0
Btu/h
215,000
324,000
kcal/h
54,200
Maximum
allowable
piping length
Actual
piping length
Example
170 m
a+f+g+h+i
200 m
640 m
a+b+c+d+e+f+g+h+i
f+g+h+i
Between the first indoor branch and the farthest indoor unit
90 m*
Equivalent
piping length
mm
2,170
2,170
mm
1,690
2,100
Depth
mm
800
800
Cooling
Power
consumption
Heating
kW
1.17
1.77
kW
1.10
1.57
Cooling
Fuel gas
consumption Heating
kW
47.4
67.7
kW
46.6
66.3
Scrollx2
Scrollx2
Compressor
Type
Type
Propeller fan
Number of units
Maximum allowable
level difference
Level
Difference
Example
15 m*1
50 m
Fans
50%130%
Connection ratio =
20
30
Capacity
index
500
750
100%
500
750
130%
650
975
Maximum number of
connectable indoor units
32
48
570
15.9
19.1
28.6
31.8
mm
22.2
28.6
inch
R3/4
R3/4
mm
60.5
60.5
kg
Refrigerant
Type
Charge
kg
15
15
860
1040
R-410A
R-410A
11.8
11.8
Yanmar genuine GHP oil
Type
Freezing temperature
-35
Sound
pressure level Quiet mode
dB(A)
58
dB(A)
55
59
Piping length;equivalent/actual
200/170
200/170
50
50
50
50
15
15
Note:
15
380
mm
Normal mode
370x3
mm
Weight
Connection ratio
370x2
Direct drive
Discharge
Engine
coolant
56.0
85.0
m3/min
GYEQ20AN
GYEQ30AN
Airflow rate
Refrigerant Suction
Piping
kW
Liquid
1. When the piping length between the indoor branch and the farthest indoor unit is 40 m or more, the maximum allowable level difference between the indoor units is
decreased.Refer to the Engineering Data Book.
Model name *1
Motor output
Drive
Connection ratio
81,700
Ivory white(5Y7.5/1)
Dimensions Width
Height
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .
GYEQ30AN
1- phase , 200 V , 50 Hz
number
capacity
62
32
48
50-130
50-130
1 Indoor temp.: 27 CDB, 19 CWB / outdoor temp.: 35 CDB / Equivalent piping length: 7.5 m, level difference: 0 m
2 Indoor temp.: 20 CDB / outdoor temp.: 7 CDB, 6 CWB/ Equivalent piping length: 7.5 m, level difference: 0 m
16
Operation range
Heating operation
25
20
10
(Note 1)
14
-10
-10
43
10
20
30
OUTDOOR TEMPERATURE (CDB)
40
30
30
RANGE FOR CONTINUOUS
OPERATION
20
15
18
-11
10
-30
-20
-10
10
20
MODEL
BSGQ100PV1
Power supply
Total capacity index of connectable indoor units
No. of connectable indoor units
Model
GYEQ20AN
GYEQ30AN
KRC19-26A
KJB111A
REFNET header
REFNET joint
KHRP25A22T,KHRP25A33T
(KHRP25A72T+KHRP25M72TP)
(KHRP25A73T+KHRP25M73TP)
Distributive
piping
Antivibration mount *1
Air direction adjuster
Air guard
Exhaust extension adaptor
Exhaust extension external drain filter
Water discharge kit
External contact output harness
20 to 100
Max. 5
Max. 8
Max. 8
Casing
Dimensions (HXWXD)
Option name
Cool/Heat selector
Fixing box
YGAS560J1
FKA560H
ARD560H
Piping
connections
Indoor Liquid
Unit
Gas
YGAS850J1
FKA850H
ARD850H
Notes:
mm
mm
Liquid
Outdoor
mm
Suction gas
Unit
High and low pressure gas
Machine weight
Sound level
BSGQ250PV1
No. of branches
BSGQ160PV1
1-phase, 220-240 V, 50 Hz
207x388x 326
9.5 (Brazing) 1
9.5 (Brazing)
9.5 (Brazing)
15.9 (Brazing) 1
15.9 (Brazing) 2
22.2 (Brazing) 3
9.5 (Brazing)
9.5 (Brazing)
9.5 (Brazing)
15.9 (Brazing)
15.9 (Brazing) 2
22.2 (Brazing) 3
12.7 (Brazing)
12.7 (Brazing) 2
kg
12.0
12.0
dB(A)
42 (32) 4
43 (32) 4
30
Cooling operation
19.1 (Brazing) 3
15.0
44 (34) 4
1 When connecting with an indoor unit with a capacity index between 20 and 50, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.)
2 When connecting with indoor units with total capacity indexes between 150 and 160, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.)
3 When connecting with indoor units with a capacity index of 200, or with total capacity indexes between 160 and 200, connect the attached pipe to the field pipe.
(Braze the connection between the attached and field pipe.)
4 Figures in brackets ( ) indicate sound levels when the all indoor units connected to the BS unit are not operating but other indoor units within the same system are operating.
HA850H
DFB19E
RGA850H1
OSH850J
*1. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof.
The specified antivibration mount must be used. Otherwise abnormal vibration may occur.
17
18
Lineup
FXFQ-SVM
To be launched
in June 2014
Indoor units
(kW)
2.2
2.8
3.6
4.5
FXFQ-SVM
To be launched
in June 2014
FXFQ-PVE
11.2
14
16
145
16.2
145
180
20
180
22.4
28
FXDQ-NBVE
Ceiling Concealed
(Duct) Type
7.1
Ceiling Mounted
Built-in
5.6
Ceiling Concealed
(Duct)
FXSYQ-MVE
FXDYQ-M(A)V1
FXDYQ-M(A)V1
19
This FXUQ model is not compatible both Heat Pump 30 class and Heat Recovery systems.
20
FXFQ25S/FXFQ32S/FXFQ40S
FXFQ50S/FXFQ63S/FXFQ80S
FXFQ100S/FXFQ125S
To be launched
in June 2014
Room temperature is
calculated as 27C in the area which
is in the vicinity of the person.
Energy savings
The temperature near the person is automatically calculated by
detecting the temperature of the floor. Energy is saved, because
the area around the feet does not get too cold.
21
Position 2
Swing
Comfortable airflow
Airflow rate automatically increases during hot or cold periods (when there
is a large difference with set temperature), and operation is rapidly
performed for cooling or heating.When the difference with set temperature
becomes small, drafts are prevented by automatically reducing airflow rate,
and raising the flap to a horizontal position during cooling operation.
Sound
level
(H/M/L)
25/32
40
50
63
80
100
125
Airflow block
for cabinet side
850 mm
Setpoint (C)
Detecting the
average
temperature of
indoor floor
Position 3
Automatic
control using
the temperature
near the person
as the room
temperature.
Position 0
Room
temperature is
detected as
30C.
20C near floor
Presence of
people in 4
areas
Airflow block
air velocity
approx. 0.3m/s*4
Sensing function
28
27
26
27C
26C
Occupied
Unoccupied
After 30 min
26C
Automatically
reverts when
people return.
Horizontal flow
Time
Shift temperature and time can be selected from 0.5 to 4C in 0.5C increments
and 15, 30, 45, 60, 90 or 120 minutes respectively with remote controller.
Airflow block
Airflow
block
500 mm*5
Wall
*1. These functions are not available when using the group control system.
*2. User can set these functions with remote controller.
22
Indoor Unit
UnitsLineup
Ceiling Mounted Cassette (Compact Multi Flow) Type
FXFQ25P/FXFQ32P/FXFQ40P
FXFQ50P/FXFQ63P/FXFQ80P
FXZQ40M / FXZQ50M
FXFQ100P/FXFQ125P
Round Flow
(240 V)(dB(A))
FXZQ-M
20/25
32
40
50
Sound level
(H/L)
32/26
34/28
37/29
42/35
Comfortable airflow
1
Auto swing
Untreated surface
Dirt and
grime Condition after
exposure to the
smoke of 600
3
cigarettes in 1 m
enclosed space.
Resists
soiling
25/32
40
50
(dB(A))
63
80
100
125
Sound
level
30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34
(HH/H/L)
850 mm
All-round flow
60
60
3-way flow
0
60
60
750 mm
23
4-way flow
3-way flow
L-shaped
2-way flow
*For 3-way or 2-way flow installation, the sealing member for air discharge outlet
(option) must be used to close each unused outlet.
24
Indoor Unit
UnitsLineup
Ceiling Mounted Cassette (Double Flow) Type
FXCQ20M/FXCQ25M/FXCQ32M
FXCQ40M/FXCQ50M/FXCQ63M
FXUQ71A/FXUQ100A
FXCQ80M/FXCQ125M
This model is not compatible both Heat Pump 30 class and Heat
Recovery systems.
305 mm
198 mm
3-way flow
(240 V)(dB(A))
FXCQ-M
20
25/32
40/50
63
80
125
Sound level
(H/L)
34/29
36/30
37/32
39/34
41/36
46/40
Position 2
600 mm
Position 3
25
Swing
26
FXKQ25MA/FXKQ32MA
FXKQ40MA/FXKQ63MA
Min.195 mm
Panel spacer
20 mm
28C
32C 30C
26C
22C
20C
Only
6 (m)
200 mm
700 mm
200 mm
900 mm
Suspension bolt*
Air filter
240 mm
AIR
Main body
500 mm
24C
1
0
Discharge grille *
AIR
Downward discharge
Suction grille *
* To be obtained locally
Main body
750 mm
(dB(A))
FXDQ-PB/NB
20/25/32
40
50
63
Sound level
(HH/H/L)
33/31/29
34/32/30
35/33/31
36/34/32
Ceiling
* The values of operation sound level represent those for rear-suction operation.
Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
of 15 Pa.
27
28
Indoor Unit
UnitsLineup
Ceiling Concealed (Duct) Type
FXSYQ20M/FXSYQ25M/FXSYQ32M
FXSYQ40M/FXSYQ50M /FXSYQ63M
FXSYQ80M/FXSYQ100M
FXSYQ125M
FXDYQ80MA/FXDYQ100MA
FXDYQ125MA/FXDYQ145MA
FXDYQ180M/FXDYQ200M
FXDYQ250M
Standard
Air suction
canvas bellows
With duct
Min.
350 mm
Access panel
Ceiling return
Long-life lter
Long-life lter
Access panel
250 mm
20/25/32
40
41/33.5 41/34.5
(230 V)(dB(A))
50
63
80/100
125
43/37
45/38.5
48/43
49/41.5
The values of operation sound level are based on Australian Standard 1217.6-1985.
Measurement is based on bottom-return air entry.
29
30
FXMQ20P/FXMQ25P/FXMQ32P
FXMQ40P/FXMQ50P/FXMQ63P
FXMQ80P/FXMQ100P/FXMQ125P
FXMQ140P
FXHQ32MA/FXHQ63MA
FXHQ100MA
Sound absorption
member
40
50
63
80/100
125
140
Sound
level 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43
(HH/H/L)
Energy-efficient
The adopted DC fan motor is much more efficient than
the conventional AC motor, yielding an approximate
20% decrease in energy consumption (FXMQ125P).
FXMQ200MA/FXMQ250MA
Straightening vane
700 mm
Ceiling
FXMQ-P 20/25
Turbulent flow
is produced
32
63
100
Sound level
(H/L)
36/31
39/34
45/37
Installation is easy
Drain pump kit (option) can be easily incorporated.
600 mm
470 mm
31
25 mm
Indoor unit
222 mm
Non-dew Flap
0250
470 mm
Maintenance is easy
Non-dew Flap with no implanted bristles
(dB(A))
FXHQ-MA
100
Indoor unit
32
FXAQ20P/FXAQ25P
FXLQ20MA/FXLQ25MA
FXAQ50P/FXAQ63P
FXLQ50MA/FXLQ63MA
FXLQ32MA/FXLQ40MA
FXAQ32P/FXAQ40P
(dB(A))
FXAQ-P
20
25
32
40
50
63
Sound level
(H/L)
35/31
36/31
38/31
39/34
42/37
47/41
Wall hanging
Floor installation
FXNQ20MA/FXNQ25MA
FXNQ32MA/FXNQ40MA
FXNQ50MA/FXNQ63MA
Drain pump kit is available as optional accessory, which
lifts the drain 1,000 mm from the bottom of the unit.
Height of drain-up
1,000 mm
33
Connecting
port
Refrigerant
piping
* Applies also to Floor Standing type (FXLQ-MA).
34
kcal/h
Cooling capacity
Btu/h
kW
kcal/h
Heating capacity
Cooling
Power consumption
Heating
Casing
12,300
2.8
2,800
Liquid (Flare)
Gas (Flare)
3,900
4,800
6,100
7,700
9,600
12,000
15,400
19,100
24,200
30,700
38,200
47,800
4,300
Dimensions(HWD)
Weight
8,600
10,800
13,800
12.5
16.0
13,600
17,100
21,500
27,300
34,100
3.2
4.0
5.0
6.3
8.0
10.0
0.031
0.041
0.080
0.095
0.194
0.219
0.027
0.037
0.075
0.090
0.180
0.199
kW
kW
dB(A)
dB(A)
mm
208/191/166
47/45.5/44
19
mm
12.7
Panel
(Option)
Power consumption
Casing
Cooling
Heating
Panel
(Option)
3,900
4,800
6,100
7,700
9,600
12,000
Btu/h
9,600
12,300
15,400
19,100
2.8
3.6
4.5
5.6
24,200
30,700
38,200
47,800
kW
7.1
9.0
11.2
14.0
3,400
4,300
5,400
17,100
21,500
kW
3.2
4.0
Gas (Flare)
Weight
54,600
42,700
6.3
8.0
12.5
16.0
0.052
0.066
0.093
0.187
0.209
kW
0.027
0.034
0.038
0.053
0.075
0.174
0.200
/s
216/191/166
dB(A)
30/28.5/27
48/46.5/45
m3/min
dB(A)
13/11.5/10
mm
10.0
mm
19.5
246840840
32/26/20 33/28/22.5
288840840
22
6.4
25
9.5
12.7
15.9
VP25 (External Dia, 32/Internal Dia, 25)
BYCP125K-W1
Model
Dimensions(HWD)
13,800
10,800
5.0
Drain
Colour
34,100
0.047
kg
Liquid (Flare)
8,600
6,900
27,300
0.033
kW
Fresh white
mm
50X950X950
kg
5.5
35
8,500
10,900
2.5
3.2
0.073
3.6
3,400
13,600
4.0
0.076
4,800
3,900
15,400
4.5
17,100
5.0
21,500
6.3
0.115
0.089
183/133
233/166
240 V dB(A)
32/26
240 V dB(A)
49
34/28
37/29
42/35
0.064
9/7
9.5/7.5
51
mm
Dimensions(HWD)
11/8
54
kg
18
mm
12.7
59
6.4
VP20 (External Dia, 26/Internal Dia, 20)
BYFQ60B8W1
White (6.5Y9.5/0.5)
mm
55700700
2.7
kg
MODEL
Btu/h
kW
kcal/h
Btu/h
Heating capacity
kW
6,900
9,600
27,300
38,200
8.0
11.2
7,700
10,800
30,700
42,700
9.0
Cooling
kW
Heating
0.090
kW
0.073
Casing
FXUQ100AVEB
FXUQ71AVEB
kcal/h
Cooling capacity
12.5
0.200
0.179
Fresh white
/s
375/325/267
517/433/350
m3/min
22.5/19.5/16
31/26/21
dB(A)
47/44/40
dB(A)
40/38/36
Dimensions (HWD)
mm
Machine weight
kg
Liquid (Flare)
Piping
Gas (Flare)
connections
Drain
14/10
286575575
Colour
Power
consumption
5.6
158/125
Power supply
19,100
5,400
4,300
3,100
13,600
2.8
2,800
3,100
12,300
150/116
/s
Weight
2,400
2,800
2.2
2,200
Model
5.5
10,900
9,600
0.107
Piping
Gas (Flare)
connections
Drain
50950950
Btu/h
7,500
FXZQ50MVE
0.080
Dimensions (HWD)
Fresh white
FXZQ40MVE
0.068
m3/min
FXZQ32MVE
Liquid (Flare)
kcal/h
kcal/h
kW
Machine weight
Power supply
Heating
BYCQ125B-W1
kg
kW
15.9
mm
Cooling
Casing
MODEL
Heating capacity
Power
consumption
9.5
Cooling capacity
kW
26
23
2,400
Btu/h
Heating capacity
288840840
6.4
1,900
Btu/h
kW
FXZQ25MVE
kcal/h
30/28.5/27
FXZQ20MVE
kcal/h
Cooling capacity
54,600
42,700
12.5/11.5/10.0
Model
Colour
6,900
MODEL
Power supply
14.0
11.2
9.0
7.1
5,400
10,900
Drain
Panel
(Option)
5.6
4.5
3.6
3,400
kg
Machine weight
Piping
connections
3,100
9,600
kW
m3/min
2,400
Btu/h
/s
MODEL
Power supply
58/56/54
65/62/58
198950950
26
27
9.5
mm
15.9
VP20 (External Dia, 26/Internal Dia, 20)
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
(See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
36
MODEL
Power supply
kcal/h
1,900
2,400
3,100
3,900
4,800
6,100
7,700
12,000
Btu/h
7,500
9,600
12,300
15,400
19,100
24,200
30,700
47,800
kcal/h
2,200
2,800
3,400
4,300
5,400
6,900
8,600
13,800
Btu/h
8,500
10,900
13,600
17,100
21,500
27,300
34,100
54,600
kW
Cooling
2.5
3.2
4.0
5.0
6.3
8.0
10.0
16.0
kW
Heating
0.077
0.092
0.130
0.106
0.209
0.256
kW
0.044
0.059
0.097
0.126
0.176
0.223
Cooling capacity
kW
Heating capacity
Power
consumption
2.2
2.8
3.6
5.6
7.1
9.0
14.0
Casing
/s
m3/min
240 V
Dimensions (HWD)
Machine weight
dB(A)
mm
116/83
150/108
200/150
275/216
433/350
550/416
7/5
9/6.5
12/9
16.5/13
26/21
33/25
34/29
36/30
37/32
39/34
41/36
46/40
305990600
305775600
26.0
kg
31.0
Liquid (Flare)
Piping
Gas (Flare)
connections
Drain
mm
Colour
Weight
32.0
35.0
mm
531,030680
kg
8.0
3051,665600
47.0
48.0
6.4
9.5
12.7
15.9
BYBC32G-W1
Dimensions(HWD)
3051,175600
Model
Panel
(Option)
4.5
531,245680
531,430680
531,920680
8.5
9.5
12.0
Cooling capacity
Btu/h
kW
kcal/h
Heating capacity
Power
consumption
Casing
Btu/h
Cooling
Heating
240 V
kW
kW
mm
kg
Dimensions(HWD)
Weight
3,900
mm
kg
6,100
12,300
15,400
24,200
2,800
3,400
4,300
6,900
2.8
3.6
10,900
3.2
13,600
4.0
0.066
11/9
40/35
4.5
7.1
17,100
27,300
0.076
0.105
5.0
0.056
216/166
215X1,110X710
13/10
42/36
31
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
Model
Colour
3,100
FXKQ63MAVE
9,600
183/150
Liquid (Flare)
Piping
connections Gas (Flare)
Drain
Panel
(Option)
2,400
/s
mm
FXKQ40MAVE
0.046
Dimensions (HWD)
Machine weight
FXKQ32MAVE
kW
m3/min
dB(A)
BYK45FJW1
White (10Y9/0.5)
8.0
0.085
300/250
18/15
44/39
215X1,310X710
34
9.5
15.9
BYK71FJW1
70X1,240X800
70X1,440X800
8.5
9.5
37
FXDQ20PBVE
Power consumption
Cooling
Heating
Casing
Airflow rate (HH/H/L)
External static pressure
Sound level (HH/H/L)
1 3
kcal/h
1,900
Btu/h
7,500
FXDQ25PBVE
1-phase, 220-240 V/220 V, 50/60 Hz
2,400
kW
2.2
2.8
3.6
2,200
2,800
3,400
Btu/h
8,500
10,900
13,600
kW
2.5
3.2
kW
0.086
kW
0.067
4.0
0.089
0.070
/s
133/120/106
m3/min
8.0/7.2/6.4
Pa
30-10
dB(A)
33/31/29
51
mm
200700620
kg
23.0
6.4
Liquid (Flare)
Piping
Gas (Flare)
connections
Drain
3,100
12,300
9,600
dB(A)
FXDQ32PBVE
kcal/h
mm
12.7
VP20 (External Dia, 26/Internal Dia, 20)
FXKQ25MAVE
MODEL
Power supply
Heating capacity
Machine weight
BYBC125G-W1
White (10Y9/0.5)
Cooling capacity
Dimensions (HWD)
BYBC63G-W1
BYBC50G-W1
MODEL
Power supply
FXDQ40NBVE
Power supply
Cooling capacity
Heating capacity
Power consumption
Cooling
Heating
Casing
Airflow rate (HH/H/L)
External static pressure
Sound level (HH/H/L)
1 3
Dimensions (HWD)
Machine weight
Liquid (Flare)
Piping
Gas (Flare)
connections
Drain
FXDQ50NBVE
FXDQ63NBVE
kcal/h
3,900
4,800
6,100
Btu/h
15,400
19,100
24,200
kW
4.5
5.6
7.1
kcal/h
4,300
5,400
6,900
Btu/h
17,100
21,500
27,300
kW
5.0
6.3
8.0
kW
0.160
0.165
0.181
kW
0.147
0.152
0.168
/s
175/158/141
m3/min
10.5/9.5/8.5
12.5/11.0/10.0
34/32/30
35/33/31
52
53
Pa
dB(A)
dB(A)
mm
kg
mm
27.0
44-15
200900620
6.4
275/241/216
16.5/14.5/13.0
28.0
12.7
36/34/32
54
2001,100620
31.0
9.5
15.9
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1: Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.
2: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is
10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.)
3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be
obtained by adding 5 dB(A).
38
MODEL
Power supply
Cooling capacity
1-phase, 220-240 V, 50 Hz
kcal/h
1,900
2,400
3,100
Btu/h
7,500
9,600
12,300
kW
kcal/h
Btu/h
Heating capacity
kW
Power
consumption
Cooling
kW
Heating
kW
Casing
/s
m3/min
Pa
2.2
2.8
3.6
2,200
2,800
3,400
10,900
13,600
3.2
4.0
8,500
2.5
0.089
0.096
0.089
0.096
Piping
Gas (Flare)
connections
Drain
Weight
24,200
30,700
38,000
47,800
7.1
9.0
11.2
14.0
5,400
6,900
8,600
10,800
13,800
34,100
42,700
54,600
10.0
12.5
16.0
0.304
0.309
0.366
0.304
0.309
0.366
5.6
4.5
4,300
21,500
17,100
27,300
6.3
5.0
8.0
0.145
0.106
0.178
0.145
0.106
0.178
350/235
450/355
466/370
21/14.1
27/21.3
28/22.2 38/27.42
98-65-33
191/143
88-57-27
96-65-57
86-58-43
41/33.5
41/34.5
43/37
58/50.5
58/51.5
60/54
30
34
35
300X550X800
300X700X800
115-84-52
140-122-61
138-118-53
98-58
48/43
49/41.5
62/55.5
65.5/60
66/59
300X1,000X800
300X1,400X800
44
57
6.4
9.5
12.7
15.9
BYBS45DJW1
633/457
45/38.5
BYBS32DJW1
Dimensions(HWD)
19,100
250/190
mm
Colour
12,000
158/112
Model
Panel
(Option)
9,600
kg
Liquid (Flare)
7,700
9/6.72
mm
Machine weight
6,100
150/112
15,400
4,800
230 V dB(A)
3,900
BYBS71DJW1
White (10Y9/0.5)
55X650X500
55X800X500
55X1,100X500
55X1,500X500
3.0
3.5
4.5
6.5
Cooling capacity
kcal/h
7,600
9,600
12,000
13,800
17,200
19,300
24,100
Btu/h
30,000
38,200
47,400
54,600
68,200
76,400
95,500
kcal/h
Btu/h
Heating capacity
kW
Power
consumption
Cooling
kW
Heating
kW
Casing
/s
m3/min
8,480
33,800
11.2
mm
kg
mm
13.9
10,800
13,800
42,700
54,600
12.5
16.0
0.700
0.780
0.415
0.700
0.780
510
778
30.6
46.7
45
46
50
60
9.9
0.415
120
360X1168X869
16.0
15,800
62,800
18.4
0.880
20.0
22.4
19,300
21,500
76,400
85,300
22.4
25.0
0.980
0.880
0.980
852
957
51.1
57.4
1.020
360X1478X899
65
15.9
9.5
107,500
31.5
1.200
1,180
1,200
1,400
70.8
72.0
84.0
180
200
51
66
27,100
1.200
150
48
28.0
1.020
Pa
240 V dB(A)
Dimensions (HWD)
8.8
500X1210X910
77
79
19.1
500X1410X910
98
22.2
39
1,900
2,400
3,100
3,900
4,800
Btu/h
7,500
9,600
12,300
15,400
19,100
kW
2.2
2.8
3.6
4.5
5.6
kcal/h
2,200
2,800
3,400
4,300
5,400
Btu/h
8,500
10,900
13,600
17,100
21,500
kW
2.5
3.2
4.0
5.0
6.3
0.060
0.151
0.128
0.073
0.182
0.203
158/133/116
267/216/183
300/275/250
9.5/8/7
16/13/11
Cooling
kW
0.056
Heating
kW
0.069
Casing
Airflow rate (HH/H/L)
External static pressure
Sound level (HH/H/L)
Sound power (H)
Dimensions (HWD)
Power supply
kW
Power consumption
kcal/h
/s
9/7.5/6.5
Pa
30-100 (50)
dB(A)
dB(A)
30-160 (100)
33/31/29
34/32/30
51
52
mm
18/16.5/15
2
39/37/35
300X550X700
25
kg
50-200 (100)
41/39/37
57
59
300X700X700
300X1,000X700
28
36
6.4
mm
12.7
VP25 (External Dia, 32/Internal Dia, 25)
kcal/h
Cooling capacity
Btu/h
kW
Heating capacity
Power consumption
150/125/108
m3/min
MODEL
Heating capacity
Piping
connections Gas (Flare)
Drain
kg
Power supply
Cooling capacity
Liquid (Flare)
mm
MODEL
Machine weight
BYBS125DJW1
MODEL
Power supply
Cooling
Heating
6,100
7,700
9,600
12,000
13,800
24,200
30,700
38,200
47,800
54,600
7.1
9.0
11.2
14.0
16.0
kcal/h
6,900
8,600
10,800
13,800
15,500
Btu/h
27,300
34,100
42,700
54,600
61,400
kW
8.0
10.0
12.5
16.0
18.0
kW
0.138
0.185
0.215
0.284
0.405
kW
0.218
0.286
0.364
0.449
0.449
766/649/533
Casing
Airflow rate (HH/H/L)
External static pressure
Sound level (HH/H/L)
Sound power (H)
Dimensions (HWD)
Machine weight
Liquid (Flare)
Piping
connections Gas (Flare)
Drain
/s
m3/min
Pa
dB(A)
dB(A)
mm
kg
mm
325/292/267
417/375/333
533/450/383
650/550/466
19.5/17.5/16
25/22.5/20
32/27/23
39/33/28
50-200 (100)
46/39/32
50-140 (100)
42/40/38
43/41/39
44/42/40
46/45/43
60
61
62
64
300X1,400X700
300X1,000X700
36
46
47
9.5
15.9
VP25 (External Dia, 32/Internal Dia, 25)
40
MODEL
19,300
kW
Power consumption
Casing
Cooling
Heating
Btu/h
85,300
107,500
kW
25.0
kW
1.294
kW
1.294
240 V
Dimensions (HWD)
Machine weight
Piping
connections Gas (Flare)
Drain
1.465
1.465
Heating capacity
1
Power consumption
Pa
966/833
1,200/1,033
58/50
72/62
132-221
dB(A)
191-270
3,100
3,900
4,800
6,100
7,500
9,600
12,300
15,400
19,100
24,200
kcal/h
2,200
2,800
3,400
4,300
5,400
6,900
Btu/h
8,500
10,900
13,600
17,100
21,500
27,300
kW
2.5
3.2
4.0
5.0
6.3
8.0
kW
0.019
0.028
0.030
0.020
0.033
0.050
kW
0.029
0.034
0.035
0.020
0.039
0.060
/s
m3/min
dB(A)
Dimensions (HWD)
Machine weight
470X1,380X1,100
mm
2.2
2.8
Piping
connections Gas (Flare)
Drain
9.5
19.1
22.2
3.6
4.5
5.6
7.1
White (3.0Y8.5/0.5)
125/75
133/83
142/91
200/150
250/200
316/233
7.5/4.5
8/5
8.5/5.5
12/9
15/12
19/14
35/31
36/31
290795238
38/31
39/34
42/37
2901,050238
47/41
kg
11.0
Liquid (Flare)
137
mm
Heating
49/46
mm
Cooling
Casing
kg
Liquid (Flare)
31.5
2,400
kW
27,100
1,900
Btu/h
28.0
21,500
m3/min
22.4
Cooling capacity
95,500
kcal/h
/s
24,100
76,400
Btu/h
Heating capacity
MODEL
Power supply
kcal/h
Cooling capacity
FXMQ250MAVE
14.0
6.4
9.5
12.7
mm
15.9
PS1B
MODEL
Power supply
kcal/h
Cooling capacity
Heating
Casing
Airflow rate (H/L)
9,600
38,200
3.6
7.1
11.2
kW
kW
kW
/s
m3/min
Machine weight
kg
Piping
connections Gas (Flare)
Drain
6,100
24,200
dB(A)
Liquid (Flare)
3,100
12,300
Dimensions (HWD)
FXHQ100MAVE
kW
Btu/h
Cooling
FXHQ63MAVE
1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h
kcal/h
Heating capacity
Power consumption
mm
3,400
6,900
10,800
13,600
27,300
42,700
4.0
8.0
12.5
0.111
0.115
0.135
0.111
0.115
0.135
200/166
291/233
416/325
12/10
17.5/14
25/19.5
45/37
36/31
39/34
195960680
1951,160680
24.0
28.0
6.4
mm
White (10Y9/0.5)
12.7
1951,400680
33.0
9.5
15.9
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book
for details.)
Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXHQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions
1: Power consumption values are based on conditions of rated external static pressure.
2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".
41
MODEL
Power supply
FXLQ
Cooling capacity
Btu/h
kW
Heating capacity
FXNQ
Power consumption
Cooling
Heating
Casing
FXNQ
Machine weight
FXLQ
FXNQ
3,900
4,800
6,100
9,600
12,300
15,400
19,100
24,200
2.2
2.8
3.6
4.5
5.6
7.1
2,800
3,400
4,300
5,400
6,900
Btu/h
8,500
10,900
13,600
17,100
21,500
27,300
kW
2.5
3.2
4.0
5.0
6.3
8.0
kW
0.049
0.090
0.110
kW
0.049
0.090
0.110
dB(A)
mm
kg
Liquid (Flare)
Piping
connections Gas (Flare)
Drain
3,100
7,500
2,200
m3/min
FXLQ
2,400
kcal/h
/s
1,900
mm
Power supply
133/100
183/141
233/183
266/200
7/6
8/6
11/8.5
14/11
16/12
35/32
38/33
39/34
40/35
6001,000222
6001,140222
6001,420222
610930220
6101,070220
6101,350220
19.0
23.0
27.0
25.0
30.0
36.0
6.4
9.5
12.7
15.9
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book
for details.)
Sound level: (FXAQ-P) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
(FXLQ-MA, FXNQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
42
5
6
7
Item
Decoration panel
Sealing material of air discharge outlet
Panel spacer
Filter related
High efficiency filter unit 65%
High efficiency filter unit 90%
Replacement high efficiency filter 65%
Replacement high efficiency filter 90%
Filter chamber
Long life replacement filter
Ultra long-life filter
Replacement ultra long-life filter
Fresh air intake kit
Chamber type Without T joint-pipe and fan
With T joint-pipe without fan
Direct installation type
Branch duct chamber
Insulation kit for high humidity
BYCQ125B-W1
KDBHQ55B140
KDBP55H160FA
KAFP556B80
KAFP557B80
KAFP552B80
KAFP553B80
KDDFP55B160
KAFP551K160
KAFP55B160
KAFP55H160H
KDDQ55B140
KDDP55B160K
KDDP55X160
KDJP55B80
KDTP55K80
KAFP556B160
KAFP557B160
KAFP552B160
KAFP553B160
1
2
3
4
5
6
7
8
Decoration panel
Sealing material of air discharge outlet
Panel spacer
Filter related
High efficiency filter unit 65%
High efficiency filter unit 90%
Replacement high efficiency filter 65%
Replacement high efficiency filter 90%
Filter chamber
Long life replacement filter
Ultra long-life filter
Replacement ultra long-life filter
Fresh air intake kit
Chamber type Without T joint-pipe and fan
With T joint-pipe without fan
Direct installation type
Branch duct chamber
Chamber connection kit
Insulation kit for high humidity
No.
1
No.
KDJP55B160
KDTP55K160
BYCP125K-W1
KDBH55K160F
KDBP55H160FA
KAFP556B80
KAFP557B80
KAFP552B80
KAFP553B80
KDDFP55B160
KAFP551K160
KAFP55B160
KAFP55H160H
KDDP55B160
KDDP55B160K
KDDP55X160
KDJP55B80
KKSJ55KA160
KDTP55K80
KAFP556B160
KAFP557B160
KAFP552B160
KAFP553B160
KDTP55K160
Type
Item
FXZQ20M
FXZQ25M
Decoration panel
Sealing material of air discharge outlet
Panel spacer
Replacement long-life filter
Fresh air intake kit
Direct installation type
Item
FXZQ32M
FXZQ40M
FXZQ50M
BYFQ60B8W1
KDBH44BA60
KDBQ44BA60A
KAFQ441BA60
KDDQ44XA60
Type
FXUQ71A
1
2
Decoration panel
Filter related
FXCQ20M
FXCQ25M
43
Item
Panel related
Type
Decoration panel
Panel spacer
Long life replacement filter
Air discharge grille
Air discharge blind panel
Flexible duct (with shutter)
BYBC32G-W1
KAFJ532G36
KAFJ533G36
KDDFJ53G36
KAFJ531G36
FXCQ50M
BYBC50G-W1
KAFJ532G56
KAFJ533G56
KDDFJ53G56
KAFJ531G56
FXCQ63M
No.
1
FXKQ32MA
BYK45FJW1
KPBJ52F56W
KAFJ521F56
K-HV7AW
KDBJ52F56W
KFDJ52FA56
Decoration panel
Access panel
High efficiency filter 65% 1
High efficiency filter 90% 1
Long life replacement filter
Filter chamber for bottom suction
Air suction canvas
Screening door
BYBC63G-W1
KAFJ532G80
KAFJ533G80
KDDFJ53G80
KAFJ531G80
FXCQ125M
BYBC125G-W1
KAFJ532G160
KAFJ533G160
KDDFJ53G160
KAFJ531G160
FXKQ40MA
FXDQ63NB
FXSYQ20M
FXSYQ25M
FXSYQ32M
BYBS32DJW1
KTBJ25K36W
KAFJ252L36
KAFJ253L36
KAFJ251K36
KAJ25L36D
KSA-25K36
KBBJ25K36
KDT25N63
FXSYQ40M
FXSYQ50M
FXSYQ63M
BYBS45DJW1
KTB25KA56W
KAF252LA56
KAF253LA56
KAFJ251K56
KAJ25LA56D
KSA-25KA56
KBBJ25KA56
BYBS71DJW1
KTB25KA80W
KAF252LA80
KAF253LA80
KAFJ251K80
KAJ25LA80D
KSA-25KA80
KBBJ25KA80
FXSYQ80M
FXSYQ100M
FXSYQ125M
BYBS125DJW1
KTB25KA160W
KAF252LA160
KAF253LA160
KAFJ251K160
KAJ25LA160D
KSA-25KA160
KBBJ25KA160
Item
KRP1B5X
Type
Item
1
2
3
4
5
6
Filter chamber
Long life replacement filter
Long life filter chamber kit
Service panel
65%
90%
White
Fresh white
Brown
Item
No.
1
Item
Item
Type
FXKQ25MA
Type
No.
FXCQ80M
FXDQ50NB
1 If installing a high efficiency filter in the Ceiling Mounted Built-in type, a filter chamber for bottom suction is required.
FXCQ40M
FXDQ32PB
KDT25N50
Filter related
1
2
3
KDBHP49B140
KDBTP49B140
KAFP551K160
Type
Item
No.
Item
Panel related
Note:
FXDQ40NB
FXUQ100A
Type
Item
No.
KDJP55B160
FXDQ25PB
KDT25N32
Item
FXDQ20PB
Type
Item
Item
FXMQ20P
FXMQ25P
FXMQ32P
FXMQ40P
KAF372AA36
KAF373AA36
KDDF37AA36
KAF371AA36
KAF375AA36
KTBJ25K36W
KTBJ25K36F
KTBJ25K36T
KDAJ25K36A
KAF372AA56
KAF373AA56
KDDF37AA56
KAF371AA56
KAF375AA56
KTB25KA56W
KTBJ25K56F
KTBJ25K56T
KDAJ25K56A
FXHQ32MA
KDU50N60VE
KAF501DA56
KHFP5MA63
Type
FXAQ20P
Type FXLQ20MA
FXMQ50P
FXMQ63P
FXMQ80P
KAF372AA80
KAF373AA80
KDDF37AA80
KAF371AA80
KAF375AA80
KTB25KA80W
KTBJ25K80F
KTBJ25K80T
KDAJ25K71A
FXHQ63MA
KAF501DA80
FXMQ100P
FXMQ125P
FXMQ140P
FXMQ200MA
FXMQ250MA
KAF372AA160
KAF373AA160
KDDF37AA160
KAF371AA160
KAF375AA160
KTB25KA160W
KTBJ25K160F
KTBJ25K160T
KDAJ25K140A
KDU50N125VE
KHFP5MA160
KDU30L250VE
KAFJ372L280
KAFJ373L280
KDJ3705L280
KAFJ371L280
FXHQ100MA
KAF501DA112
FXAQ25P
FXAQ32P
FXAQ40P
FXAQ50P
FXAQ63P
FXLQ25MA
FXLQ32MA
FXLQ40MA
FXLQ50MA
FXLQ63MA
KAFJ361K28
K-KDU572EVE
KAFJ361K45
KAFJ361K71
KAFJ361K45
KAFJ361K71
FXKQ63MA
BYK71FJW1
KPBJ52F80W
KAFJ521F80
K-HV9AW
KDBJ52F80W
KFDJ52FA80
44
Control Systems
Individual Control Systems for Indoor Units
Convenience
Clear display
Dot matrix display
Setback (default:OFF)
Setback
temperature
Recovery
differential
Cooling
33
37C
-2
-8C
Heating
10
15C
+2
+8C
Weekly schedule
Backlight display
5 actions per day can be scheduled for each day of the week.
The holiday function will disable schedule timer for the days that have been set as holiday.
3 independent schedules can be set. (e.g. summer, winter, mid-season)
College classroom sample (a summer Monday case)
BRC1E62
1) 8:30
ON
2) 10:00
ON
Simple operation
OFF
3) 13:00
ON
4) 15:00
OFF
ON
OFF
OFF
Large buttons and arrow keys enable easy operation. Basic setting such as fan
speed and temperature can be intuitively operated. For other settings just select
the function from the menu list.
Guide on display
Multingual display
Energy saving
11 display languages are available. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish and Polish)
Until now only the temperature for one point could be set, but now the new
remote controller (BRC1E62) allows the setting of both Cooling and Heating,
and with the fan operation, mid-range temperatures are comfortable and
operation is more energy efficient.
20C
26C
Fan operation
operation
Cooling / Heating
Heating
Comfort
2 setpoints
Airflow direction of each of the four air outlets can be controlled individually.
(Positions 0 to 4, Swing, and No individual setting are selectable.)
Cooling
operation
Outlet mark
Control Systems
Restaurant sample
Restaurant opened
Temperature is set to 27C
27 C
24 C
After 30 minutes*
Automatically returns to preset
temperature (27C) Returns to
27 C
Off timer
03
45
automatically
Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.
*1 Only available for 4-Way Flow Ceiling Suspended type FXUQ-A series and Ceiling Mounted Cassette (Round Flow with Sensing) type FXFQ-S series.
04
46
Control Systems
Individual Control Systems for Indoor Units
Wireless remote controller (Option)
The same operation modes and settings as with wired remote controllers are
possible.
In all the series of GHP, Cool/Heat changeover in the same refrigerant circuit can be changed by the remote
controller of the indoor unit.
Outdoor
unit
* Individual airflow direction, auto airflow rate and sensing sensor control can be set only via wired remote controller
BRC1E62. Cannot be set via other remote controllers.
A compact signal receiver unit (separate type) to be mounted into a wall or ceiling
is included.
Group control
One remote controller can control the
operation of max.16 indoor units at the
same time.
Equipment
related to the
central control
A signal receiver unit (installed type) for a Ceiling Mounted Cassette (Round Flow,
Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall
Mounted type is mounted into the indoor unit.
Remote controller
Indoor unit
Remote controller
* Wireless remote controller and signal receiver unit are sold as a set.
Forced OFF
input
Remote controller
Remote
controller
Remote controller
Heat Reclaim
Ventilator
Concealed type
Remote
controller
Exposed type
(BRC2C51)
Remote
controller
Remote
controller
Wireless remote
controller
Remote control
FXFQ-S FXFQ-P
Nav Ease
FXZQ
FXCQ
FXUQ
FXKQ
FXDQ
FXSYQ
FXDYQ
FXMQ
FXHQ
FXAQ
FXL(N)Q
Control Systems
03
47
(Exposed type)
(BRC2C51)
04
48
Control Systems
Centralised Control Systems for Indoor Units
Up to 64 groups of indoor units (128 units) can be centrally controlled.
Optional controllers for centralised control can be combined
freely, and system can be designed in accordance with building
scale and purpose.
DCS302CA61
Connection of
up to 8 units
possible
Independent
and centralised
control of Heat
Reclaim
Ventilator is
possible.
8 units
Up to 2 units
connectable
Central control
adaptor kit
(DTA107A55).
Outdoor-air
processing
unit can be
connected.
7 cores max.
03
49
6 cores
Schedule timer (DST301BA61)
1 unit connection possible;
8 weekly schedule control patterns possible
Wiring adaptor
for other airconditioners
(DTA103A51)
DST301BA61
schedule patterns can be set, while the central controller can be used to select desired
zones. Up to 2 ON/OFF pairs can be set per day.
Max. 48 hours back up power supply
Max. wiring length 1,000 m (Total: 2,000 m)
Compact size casing (Thickness: 16 mm)
Connectable with Central Remote controller, Unified ON/OFF controller and BMS
system
Control Systems
Forced
shut-down
input
Central remote
controller
(DCS302CA61)
Connectable number of
centralised control
equipment
Unified on/off
controller
Unified on/off
controller
(DCS301BA61)
04
50
Control Systems
Advanced Control Systems for Indoor Units
Interface for
BACnet
and LONWORKS
Integrated control systems that recognise the trend of open control systems
Ethernet
BMS
DCS601C51
Lift
Pump
Lighting,etc
Fire alarm Security Power supply facility
DMS502B51
DMS504B51
GHP System
Local Controller
D -NET
Indoor Unit
Features
Colour LCD touch panel icon display
Small manageable size
Simplified engineering
Multi language (English, French, Italian, German, Spanish,
Heat Reclaim
Ventilator
Compatibility with BMS enhanced by utilising the international communication standards, BACnet or LONWORKS.
DMS502B51
DMS504B51
Control Systems
RS-232C
Heat
Reclaim
Ventilator
Yearly schedule
Auto heat/cool change-over
Temperature limitation
Enhanced history function
Built-in modem for connecting to Air Conditioning Network Service System (Option)
Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option)
03
51
04
52
Control Systems
Integrated Building Monitoring System
DIII-NET Line
The high speed transmission of DIII-NET enables more advanced control of the GHP system, providing
you with enhanced comfort.
BACnet/Ethernet or LONWORKS
Network Communication Line
Contact Signal Line
Close control and monitoring by integrating a wide variety of air-conditioners in the entire building.
Saving the in-building cabling using non-polar, two-wire cables. Easier wiring work with
tremendously fewer wiring errors.
Additional setups readily up and running. An extendable cabling up to 2 km in total.
Different control equipment flexibly joined in the system for hierarchical risk diversification.
Daikin's total heat exchangers and other devices under integral control.
GHP
(DCS601C51)
D -NET
(DCM601A51)
Unified ON/OFF
Controller
(DCS301BA61)
Schedule Timer
(DST301BA61)
BMS
(Obtain locally)
SkyAir
Packaged
Air-conditioner
Residential Air-conditioner
Wiring adaptor
for electrical appendices
(KRP2A61/62/53)
03
53
Control Systems
Central Remote
Controller
(DCS302CA61)
VRV
Electrical equipment
Supply water and drainage equipment
Automatic fire alarm
Parking equipment
Lift
Ventilation equipment
Lighting
Crime and fire prevention equipment
Caution:
Limitation may apply to some models and functions. Please contact your local sales office for details.
Consultation is necessary before employing this control system. Please contact your local sales office before
making a purchase.
Note: BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning
Engineers (ASHRAE). LONWORKS is a trademark of Echelon Corporation registered in the United
States and other countries.
04
54
Control Systems
Option List
Operation Control System Optional Accessories
No.
1
2
3
4
5
6-1
6-2
7
Item
Type
Wireless
Remote controller
Navigation remote controller (Wired remote controller)
Simplied remote controller (Exposed type)
Remote controller for hotel use (Concealed type)
Adaptor for wiring
Wiring adaptor for electrical appendices (1)
Wiring adaptor for electrical appendices (2)
Remote sensor (for indoor temperature)
9
10
No.
1
2
3
4
5
6-1
6-2
7
Item
Type
Remote controller
Wireless
Navigation remote controller (Wired remote controller)
Simplied remote controller (Exposed type)
Remote controller for hotel use (Concealed type)
Adaptor for wiring
Wiring adaptor for electrical appendices (1)
Wiring adaptor for electrical appendices (2)
Remote sensor (for indoor temperature)
10
FXFQ-S
FXFQ-P
FXZQ-M
FXUQ-A
FXCQ-M
FXKQ-MA
KRP1B61
KRP1C63
KRP1BA57
KRP1B61
KRP2A61
KRP2A62
KRP2A62
KRP2A61
KRP4AA53
KRP4AA53 KRP4AA53 KRP4AA51 KRP4AA51
KRCS01-4B
KRCS01-1B KRCS01-4B
KRCS01-1B
Note 2, 3
Note 4, 6
KRP1H98
DTA104A62
DTA114A61
KRP1BA101
DTA104A62
FXSYQ-M
FXDYQ-M(A)
FXMQ-P
BRC4C62
BRC4C62
BRC4C65
Note 5
BRC2C51
BRC3A61
KRP1C64
KRP2A61
KRP4AA51
KRCS01-4B
KRP1B61
KRP2A61
KRP4AA51
KRCS01-1B
Note 2, 3
KRP1BA97
FXHQ-MA
BRC4C62
BRC7EA63W
BRC1E62 Note 7
KRP1B61
KRP2A61
KRP4AA51
DTA104A61
DTA104A61
DTA104A61
DTA114A61
BRC4C65
BRC2C51
BRC3A61
KRP1B56
KRP2A53
KRP4A54
KRCS01-1B
Note 4, 6
KRP1B96
KRP1BA101
DTA104A61 DTA104A61 DTA104A53
FXMQ-MA
KRP4A96
KRP4A91
Note 2, 3
FXDQ-PB
FXDQ-NB
FXAQ-P
BRC7EA618
KRP1BA54
KRP2A62
KRP2A61
KRP4AA52 KRP4AA51
KRCS01-1B
Note 3
KRP1CA93
Note 2, 3
KRP4AA93
DTA104A62 DTA104A61
DTA114A61
FXLQ-MA
FXNQ-MA
BRC4C62
BRC2C51
BRC3A61
KRP1B61
KRP2A61
KRP4AA51
DTA104A61
No.
Item
Model No.
Up to 16 groups of indoor units (128 units) can be easily controlled using the
large LCD panel. ON/OFF, temperature settings and scheduling can be controlled
individually for indoor units.
DCS302CA61 Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneKJB311AA
ously. Connectable up to 2 controllers in one system.
DCS301BA61 Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or
KJB212AA
simultaneously, and operation and malfunction can be displayed. Can be used in
combination with up to 8 controllers.
KEK26-1A
Programmed time weekly schedule can be controlled by unied control for up to
DST301BA61
64 groups of indoor units (128 units). Can turn units ON/OFF twice per day.
Note 2
DCS303A51
2-1
3
3-1
3-2
Function
Schedule timer
For C(F)DK(X)S,
KRP928BB2S
FTK(X)S, FVXS, FLXS
Adaptors required to connect products other than those of the VRV System to the
For FCQ-B, FFQ-B,
DTA112BA51 high-speed DIII-NET communication system adopted for the VRV System.
FHQ-BV, FBQ-B
* To use any of the above optional controllers, an appropriate adaptor must be
installed on the product unit to be controlled.
Central control adaptor kit For UAT(Y)-K(A),FD-K DTA107A55
DIII-NET
Expander Adaptor
9-1
5
6
DTA103A51
Up to 1024 units can be centrally controlled in 64 different groups.
Wiring restrictions (max. length: 1,000m, total wiring length: 2,000m, max. number of branches: 16) apply to each adaptor.
DTA109A51
For GYAQ8,10,13,16,
20,25ANV1
For GYAQ30ANV1,
GYEQ20,30AN
AGDTA109E1
COB850J
Item
intelligent Touch
Controller
Basic
Option
intelligent Touch
Hardware
Controller
DIII-NET plus
Hardware
adaptor
Model No.
DCS601C51
DCS601A52
1-2
Hardware
intelligent Touch
Manager
KJB411A
DCM601A51
Option
DCM601A52
2-1
intelligent Touch
Manager
2-2
2-3
2-4
Di unit
3
3-1
3-2
Communication
interface
4
5
DEC101A51
Dio unit
Contact/analogue signal
Function
DEC102A51
*1 Interface for use in BACnet
DMS502B51
DAM411B51
Optional Di board
DAM412B51
DMS504B51
DCS302A52
Control Systems
System Conguration
Notes: *1. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
*2. LonWorks is a trademark of Echelon Corporation registered in the United States and other countries.
*3. Installation box for adaptor must be obtained locally.
03
55
04
56
Combine fresh air treatment and air conditioning,supplied from a single system.
Lineup
Model Name FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1
Capacity Index
125
200
250
Airflow rate
Air conditioning and outdoor air processing can be accomplished using a single system.
Air
Conditioning
Outdoor
Air Supply
Heating
Supported
Range
Operation
5
Connection Conditions
The following restrictions must be observed in order to maintain the indoor units connected to the same system.
When outdoor-air processing units are connected to GHP heat pump series 8-25 class outdoor unit, the total connection capacity index must be 50% to 100% of the capacity
index of the outdoor units. When outdoor-air processing units are connected to GHP heat pump series 30 class outdoor unit, the total connection capacity index must be 80%
to 108% of the capacity index of the outdoor unit.
When outdoor-air processing units and standard indoor units are connected to GHP heat pump series 8-25 class outdoor unit, the total connection capacity index of the
outdoor-air processing units must not exceed 30% of the capacity index of the outdoor units.
A mixed combination of outdoor-air processing units and standard indoor units can not be connected to GHP heat pump series 30 class outdoor unit.
57
Supported Cooling
Operation Range
td
Ou
ur
at
r
pe
m
Te )
ir WB
A
or (C
Indoor Unit
90
Indoor Unit
10
0%
H R
Re umi elat
lat dity ive
ive
Hu
m
idi 32
ty
Usage Limitations
Fan
Operation
15
19
30%
ve
elati
idity
Hum
(33.5)
BRC1E62
Nav Ease
(Wired remote controller)
(option)
The self-diagnosis function indicates the occurrence and nature of abnormalities in the system
by displaying codes on the remote controller.
1,080 m3/h
1,680 m3/h
2,100 m3/h
FXMQ125MFV1
FXMQ200MFV1
FXMQ250MFV1
e
lativ
Re ity
20% umid
H
43
Notes:
1. The data shown in the graph illustrates the supported operation ranges under
the following conditions.
Indoor and Outdoor Unit
Effective piping length: 7.5 m
Height differential: 0 m
2. The discharge temperature can be set using the remote controller. However,
the actual temperature may not match the temperature setting under some
circumstances due to the outdoor-air processing load or mechanical protection
controls.
3. The system will not operate in fan mode when the outdoor air temperature is
5 or below.
DCS302CA61
Central remote controller
(option)
Air Treatment
Equipment Lineup
58
Dimensions
Indoor unit
FXMQ125/200/250MFV1
28.0
kcal/h
7,700
12,000
15,000
Btu/h
30,400
47,400
59,400
8.9
13.9
17.4
0.548
0.638
Airflow rate
External static pressure
470X744X1,100
470X1,380X1,100
kW
/s
300
466
583
Pa
225
275
255
m3/min
240 V
0.380
18
28
Air filter
35
*2
Liquid
mm
Gas
mm
Drain
mm
Machine weight
Sound level *3
240 V
9.5 (flare)
15.9 (flare)
22.2 (brazing)
kg
86
123
dB(A)
43
48
8 class and above
Cooling
19 to 43
-5 to 15
Cooling
13 to 25
Heating
18 to 30
*4. Only Heat Pump series outdoor units can be connected. Refer to page 57 for connection
condition details.
*5. Local setting mode. Not displayed on the remote controller.
This equipment cannot be incorporated into the remote group control of the GHP system.
FXMQ200/250MFV1
11X100=1100
1200
1230
30
1
2
3
4
5
6
7
8
9
10
11
12
12
61
20- 7 hole
(All around)
5X100=500
600
630
30
A View
DST301BA61
KRP4AA51
KAFJ371L140
KAFJ371L280
KAFJ372L140
KAFJ372L280
KAFJ373L140
KAFJ373L280
KDJ3705L140
KDJ3705L280
KDU30L250VE
KRP1B61
Some options may not be used in combination.
Operating sound may increase somewhat depending on the options used.
200
346
360
330
200
1230
360
16-M5 hole
(All around)
KRP2A61
5X200=1000
16-M5 hole
(All around)
10-M5 hole
(All around)
2X200=400
580
630
B View
Air Treatment
Equipment Lineup
DCS301BA61
Schedule timer
250
200
DCS302CA61
360
BRC1E62
FXMQ250MFV1
250
FXMQ200MFV1
330
FXMQ125MFV1
250
Operation/control
D
20- 4.7 hole
32- 4.7 hole
32- 4.7 hole
FXMQ125MFV1
245
60
32- 7 hole
(All around)
C
5X100=500
11X100=1100
11X100=1100
580
613
760
B
685
1296
1296
Notes:
1. The attached piping in the diagram is for FXMQ200MFV1 and
FXMQ250MFV1 only. The gas piping connection port ( 2 in the
diagram) has a different bore form with FXMQ125MFV1.
2. An air filter is not supplied with this unit. Be sure to mount an air
filter in the suction side.[Use a filter with dust collection efficiency of
at least 50% (gravimetric method). This is available as an option.]
3. For outdoor ducts, be sure to provide heat insulation to prevent
condensation.
A View
Model
59
B View
Indoor unit
Filter chamber *1
Options
High-efficiency
filter
2 11 6 4
30
1100
250
A View
Heating
Discharge side
19.1 (brazing)
1100 or more
(Service space)
390
Motor output
470
mm
Dimensions (HxWxD)
D
(All around)
296
0.359
50
kW
Casing
25
Power consumption
Table of dimensions
Model
A
FXMQ125MFV1 744
FXMQ200MFV1 1380
FXMQ250MFV1 1380
3X100=300
kW
360
330
3X100=300
Heating capacity *1
390
22.4
296
95,500
14.0
kW
76,400
24,100
47,800
Approx.
150
19,300
Btu/h
12,000
650 or more
(Service space)
kcal/h
Model
FXMQ125MFV1
FXMQ200MFV1
FXMQ250MFV1
Cooling capacity *1
Refrigerant
piping
FXMQ250MFV1
25
Power supply
FXMQ200MFV1
360
330
FXMQ125MFV1
1148
3X100=300
Model
Fan
9
10
250
Type
5X200=1000
1230
60
23%
Model Names
This VAM series provides higher enthalpy efficiency 1, due to the greatly enhanced performance of the thin film
element. Furthermore, improved external static pressure 2 offers more flexibility for installation. Along with these three
outstanding improvements, the nighttime free cooling operation contributes to energy conservation and more
comfortable space.
EA
Sheet structure
Outdoor
High-humidity air
Molecule of water
Miscellaneous gas
CO2 molecule, etc.
Exhaust air
Precise, thin-film
material
RA
(unclean
indoor air)
Outdoor air
(fresh air)
Supply air
2%
Pre-cool,
Pre-heat Control
Exhaust air
RA
(Return air
from room)
SA
OA
6%
Auto-ventilation Mode
Changeover Switching
Low-humidity air
31%
(Supply air
to room)
The air conditioning load reduction values are based on the following conditions;
Application: Tokyo office building
Building form: 6 floors above ground, 2 floors underground, floor area 2,100 m2
Personnel density: 0.25 person/m2
Ventilation volume: 25 m3/h
Indoor air conditioning level: summer 25 50% RH, intermediate seasons 24 50%
RH, winter 22 40% RH
Operating time: 2745 hours (9 hours per day, approx. 25 days per month)
Calculation method: simulation based on "MICRO-HASP/1982" of the Japan
Building Mechanical and Electrical Engineers Association.
Indoor unit
ON/OFF signal
Cooling/Heating mode signal
Set temperature signal
Ventilation signal
Interlocking
61
Heat Reclaim
Ventilator
Compact Equipment
Energy Conservation
With a height of just 306 mm, the unit easily fits in limited
spaces, such as above ceilings.
* For VAM500GJVE
20%
0%
Normal
ventilation fan
306 mm
The air conditioning load reduction values may vary according to weather and
other environmental conditions at the location of the machine's installation.
SA
Standard operation at
temperatures down to -15.
-15CDB
-20
-10
50CDB
10
20
30
40
50
VAM-GJ
Interlocked operation
with air conditioner
5% !
VAM-GJ
Individual operation
*1 This function can be operated only when interlocked with air conditioners.
*2 Value is based on the following conditions:
Cooling operation performed from April to October.
Calculated for air conditioning sensible heat load only
(latent heat load not included).
Cold air
Exhaust
heat
Generated
heat
Heat is discharged.
Indoor
unit
Exhaust
heat
Indoor
unit
Air Treatment
Equipment Lineup
Comfortable!
62
High
Low
High
Low
For Cooling Ultra-High
High
Low
Power
Consumption
Heat
Ultra-High
Exchange
High
Mode
Low
Bypass
Mode
Sound
Level
79
74
75
72
78
72
77
75
79
74
75
72
78
72
77
84
79
82
80
77
74
80.5
75.5
79
72
71
70
67
67.5
65
70
65
72
72
71
70
67
67.5
65
70
65
72
76
74
77
74
71.5
67.5
72.5
67
75
66
63
66
55
61
61
64
61
62
66
63
66
55
61
61
64
61
62
70
66
70
59
64
64
68.5
64
66
125
137
200
248
342
599
635
1,145
1,289
111
120
182
225
300
517
567
991
1,151
57
60
122
128
196
435
476
835
966
125
137
200
248
342
599
635
1,145
1,289
High
111
120
182
225
300
517
567
991
1,151
Low
57
60
122
128
196
435
476
835
966
27-28.5
27-29
31.5-33
33-35.5
34-36
39-40.5
39.5-41.5
39.5-41.5
41.5-43.5
26-27.5
26-27.5
30-31.5
31.5-34
33-34.5
37-39.5
37.5-39.5
37.5-39.5
39-43
20.5-21.5
21-22
23-25
25-28.5
27.5-29.5
35-37.5
35-37.5
35-37.5
36-39
28.5-29.5
28.5-30.5
33-34.5
34.5-36
35-37.5
40.5-42
40.5-42.5
41-43
43-45.5
High
27.5-28.5
27.5-29
31.5-33
33-34.5
33-35.5
38.5-40
38.5-40.5
39.5-41
40.5-45
Low
22.5-23.5
22.5-23
24.5-26.5
25.5-28.5
27.5-30.5
36-38.5
36-38.5
36.5-38
37.5-39.5
Ultra-High
Heat
Ultra-High dB(A)
Exchange
High
Mode
Low
Bypass
Mode
75
79
Ultra-High dB(A)
Casing
Insulation Material
Dimensions (HXWXD)
Machine Weigh
mm
278X810X551
kg
24
306X879X800
338X973X832
32
45
External Static
Pressure
129
Ultra-High m3/h
150
250
350
500
650
800
1,000
1,500
2,000
High
150
250
350
500
650
800
1,000
1,500
2,000
Low
100
155
230
320
500
700
860
1,320
1,720
Ultra-High
41
69
97
138
180
222
277
416
555
High
/s
41
69
97
138
180
222
277
416
555
Low
27
43
63
88
138
194
238
366
477
120
70
169
105
85
133
168
112
116
High
106
54
141
66
53
92
110
73
58
Low
56
24
67
32
35
72
85
56
Ultra-High Pa
Motor Output
kW
mm
0.030X2
100
0.090X2
150
0.140X2
200
0.280X2
250
45
Silencer (Option)
Duct
(Obtain locally)
Thermal insulation material (Obtain locally)
Option List
Type
Item
Heat Reclaim Ventilator remote controller
Residential central remote controller
Centralised Central remote controller
controlling
Unified ON/OFF controller
device
Schedule timer
Wiring adaptor for electrical
appendices
For humidifier
Installation box for adaptor PCB
For heater control kit
Notes: 1.
2.
3.
4.
OA
EA
BRC301B61
DCS303A51 *1
DCS302CA61
DCS301BA61
DST301BA61
KRP2A61
KRP50-2
KRP50-2A90 (Mounted electric component assy of Heat Reclaim Ventilator)
BRP4A50
FXFQ-S
FXDQ-PB
FXLQ-MA
Type
For wiring (indoor unit of GHP) FXFQ-P FXZQ-M FXUQ-A FXCQ-M FXKQ-MA FXDQ-NB FXSYQ-M FXDYQ-M(A) FXMQ-P FXMQ-MA FXHQ-MA FXAQ-P FXNQ-MA
Installation box for adaptor PCB
Sirocco fan
KRP1H98 KRP1BA101
KRP1B96
KRP1BA101 KRP4A91
KRP4A96
KRP1CA93 KRP4AA93
Type VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE VAM2000GJVE
KDDM24B50
KDDM24B100
KDDM24B100X2
Nominal pipe diameter mm
200
250
High efficiency filter
KAF242H25M
KAF242H50M
KAF242H65M KAF242H80M KAF242H100M KAF242H80MX2 KAF242H100MX2
Air filter for replacement
KAF241G25M
KAF241G50M
KAF241G65M KAF241G80M KAF241G100M KAF241G80MX2 KAF241G100MX2
Flexible duct (1 m)
K-FDS101D
K-FDS151D
K-FDS201D
K-FDS251D
Flexible duct (2 m)
K-FDS102D
K-FDS152D
K-FDS202D
K-FDS252D
Duct adaptor
YDFA25A1
Nominal pipe diameter mm
250
Item
Silencer
0.280X4
350
Notes: 1. Sound level is measured at 1.5 m below the centre of the body.
2. Airflow rate can be changed over to Low mode or High mode.
3. Sound level is measured in an anechoic chamber.
Sound level generally becomes greater than this value depending on the operating conditions, reflected sound, and peripheral noise.
4. The sound level at the air discharge port is about 8 dB(A) higher than the unit's sound level.
5. The specifications, designs and information given here are subject to change without notice.
6. Temperature Exchange Efficiency is the mean value between cooling and heating.
7. Efficiency is measured under the following conditions:
Ratio of rated external static pressure has been maintained as follows; outdoor side to indoor side = 7 to 1.
8. In conformance with JIS standards (JIS B 8628), operating sound level is based on the value when one unit is operated, with the value converted for an anechoic chamber. This is transmission
sound from the main unit, and does not include sound from the discharge grille. Thus it is normal for the sound to be louder than the indicated value when the unit is actually installed.
9. Sound level from the discharge port causes the value to be approximately 8 dB(A) (models with the airflow rate of less than 150 to 500 m3/h) to approximately 11 dB(A) (models with
the airflow rate of 650 m3/h or more) greater than the indicated value. Furthermore, fan rotation and noise from the discharge grille may increase depending on the on-site duct
resistance conditions. Please consider noise countermeasures when installing the unit.
10. With large models in particular (1500 and 2000 m3/h models), if the supply air (SA) grille is installed near the main unit, the noise of the main unit may be heard from the discharge
grille via the duct, and this will result in a marked increase in noise. In such cases, if peripheral effects are included (such as reverberation of the floor and walls, combination with
other equipment, and background noise), sound level may be as much as 15 dB(A) higher than the indicated value. When installing a large model, please provide as much separation
as possible between the main unit and the discharge grille. If the equipment and discharge grille are near each other, please consider countermeasures such as the following:
Use a sound-muffling box, flexible duct and sound-muffling air supply/discharge grilles
Decentralised installation of discharge grilles
11. When installing in a location with particularly low background noise such as a classroom, please consider the following measures to avoid transmission sound from the main unit:
Use of ceiling materials with high sound insulating properties (high transmission loss)
Methods of blocking sound transmission, for example, by adding sound insulating materials around the bottom of the sound source.
Alternatively, consider supplementary methods such as installing the equipment in a different location (corridor, etc.)
63
SA
157
Type
Airflow Rate
67
Air Filter
Airflow Rate
55
Round hood
(Obtain locally)
Branch duct
(Obtain locally)
Air to air cross flow total heat (Sensible heat + latent heat) exchange
SA
Additional
function
Enthalpy
Exchange
Efficiency
79
Controlling device
Ultra-High
Flexible duct
(Option)
RA
PC Board Adaptor
Power Supply
Temp. Exchange
Efficiency
EA
SA
BRP4A50
Thermostat (Obtain locally)
(OFF when the temperature is at or more
than 5)
Outdoor
Heater
(Obtain locally)
OA
Thermostat
(Obtain locally)
(ON when the temperature
is at or below -10)
Power supply (Obtain locally)
Relay box
Air Treatment
Equipment Lineup
MODEL
Options
64
Memo