GRUNDFOS DATA BOOKLET

Pumping station systems


PS.G
Pumping station, glass-fibre-reinforced plastic (GRP)

Pumping station systems

Table of contents

1.

Introduction

Introduction
Applications
Product features
Liquids

3
3
3
3

Identification

PS.S
PS.G

4
5

Selection of products

Ordering a pumping station


Selection tool

6
7

4.

CE mark

5.

Product range

2.

3.

6.

7.

8.

9.

Pipes
Direction of outlet
Pumping stations and pipe variants
Other product variants

9
11
12
16

Construction

17

Pumping station
Valve chamber
Pumping station variants
Covers
Venting pipes
Control cabinets
Service platforms
Baffle plates
Screen baskets
Level controllers

17
18
19
20
21
21
21
21
22
22

Accessories

23

Pump controllers
AUTOADAPT pumps

23
26

Installation

28

Transportation and handling


Acceptance inspection
Installation of pumping station
Backfill
Pump
Electrical installation
Commissioning

28
28
29
31
31
31
31

Dimensions

32

Starting frequency
Sump volume
Dimensions of pumping station
Dimensions of valve chamber
Dimensions of the foundation slab
Dimensions of concrete covers

32
32
33
34
35
38

10. Grundfos Product Center

42

1. Introduction
Introduction

Product features

This data booklet deals with Grundfos prefabricated


pumping stations, types PS.S and PS.G.

Corrosion-free materials

Introduction

Pumping station systems

Pipes are made of stainless steel or polyethylene.


Modular flexibility
The pumping stations consist of four main elements:
two or three high-efficiency pumps
pit size suitable for several requirements
factory-fitted pipes, valves and controllers ensure
operational efficiency and safety
standard covers and covers approved for traffic.
Many sizes available
Our pumping stations come in a full range of sizes.
Easy to install and service
The pumping station is mounted on a concrete
foundation to prevent uplift when installed in areas with
high groundwater levels.
The components of the pumping station are selected
according to Grundfos principles of high reliability, long
life and great consideration for the environment during
production, operation and disposal.

Liquids

TM06 4009 1415

Liquid temperature

Fig. 1

Grundfos pumping station

The pumping station is made of glass-fibre-reinforced


plastic (GRP) and comes with inlet and outlet pipes
pre-fitted. Pumps may be supplied separately.
The pipes are made of polyethylene (PE) or stainless
steel (AISI 304).
The pumping stations come in many variants and for a
range of applications. Special variants are available on
request.
Pumping stations are also available with a separate
valve chamber enabling the operator to access valves
without having to enter the station.
The standard cover comes in GRP and the hatch in
aluminium.

Maximum liquid temperature is 40 C. For higher


temperatures, contact Grundfos.
The liquid temperature depends on the pump selected.
See the installation and operating instructions for the
pump.
pH value
The pit is normally capable of withstanding pH values
between 5.5 to 8.0. In case of doubt or another pH
value, contact Grundfos.
Viscosity
Very thick wastewater must not be led into the pit. See
the installation and operating instructions for the pump
or Grundfos Product Center at www.Grundfos.com.
Density
Maximum 1100 kg/m3.

Applications
Grundfos prefabricated pumping stations are used for
the collection and pumping of drainage water, grey
wastewater and sewage. The type of pump depends
on the liquid being pumped.
Wastewater is led into the pit. When the liquid in the pit
reaches the start level, the pump will start moving it on
to a sewer or sewage treatment plant.

Pumping station systems

Identification

2. Identification
PS.S
Nameplate

Type key

If a complete pumping station has been configured in


the PUMPING STATION CREATOR at
www.Grundfos.com, the nameplate shown below will
be added to the pit together with a CE mark. See
section Selection tool on page 7. At the same time
Grundfos will deliver an EC declaration of conformity in
accordance with the Machinery Directive (2006/42/EC)
EN ISO 12100:2010.
1

5
4
6

11

13

Nameplate of PS.S pumping stations


Description

Product number

Production site

Type designation

Country of origin

Weight

Production code and date of production (YYWW)

Installation and operating instructions, publication number

Product number, pumping station

Product number, pump

10

Product number, pump controller

11

Product number, level controller

12

Product number, accessories

13

Not filled in

TM06 1743 2714

7
9

Pos.

Grundfos pumping station


System
Pit type and material
R:
Rotation-moulded PE
G:
Glass-fibre reinforced plastic

Pit depth x 100


40:
4000 mm

Fig. 2

PS S. G. 18. 40. SE/SL. DCD318. PT

Pit diameter
18:
1800 mm

8 10 12 13

Example

Pump type
CC:
Unilift CC
KP:
Unilift KP
AP12:
Unilift AP12.50
AP35:
Unilift AP35, Unilift AP12.40
AP50:
Unilift AP50
APB:
Unilift AP35B, Unilift AP50B
SEG:
SEG, SEG AUTOADAPT
DP, EF: DP (0.6 - 1.5 kW), EF
DP, SL: DP (2.6 kW), SL1.50.65, SLV.65.65
SE, SL: SE, SL
S:
S-pump
Pump controller
LC 108: Level controller
LCD 108: Level controller, two pumps
DC 318: Dedicated Controls
DC 319: Dedicated Controls
DCD 318: Dedicated Controls, two pumps
DCD 319: Dedicated Controls, two pumps
Level controller
FS2:
Two float switches
FS3:
Three float switches
FS4:
Four float switches
PT:
Pressure transducer

PS.G
Nameplate

Type key

The nameplate shown below is the standard


nameplate that provides information about the
pumping station and carries the CE mark of the
pumping station.
Declaration of performance is in accordance with
Annex III of Regulation (EU) No 305/2011
(Construction Product Regulation).
1

Model
Type

Example
Pumping station

Glass-fibre reinforced plastic


Pit diameter
18:
1800 mm
Pit depth x 100
40:
4000 mm

Number
S:
D:
T:

P10

Standards used: EN 12050-1 or EN 12050-2


Made in

Notified body:0197

Fig. 3
Pos.

DK-8850 Bjerringbro, Denmark

Nameplate of PS.G pumping stations


Description

Product number

Production site

Type designation

Country of origin

Weight

Production code and date of production (YYWW)

Installation and operating instructions, publication number

Not filled in

TM06 3836 1015

Weight
EU declaration of performance 96235218

1325

98495490

P.c.

PS. G. 18. 40 D. GC SS100. A100. SE/SL

Identification

Pumping station systems

of pumps
One
Two
Three

Pipe design
DC:
Direct outlet, common
GC:
Goose neck, common
VC:
Valve chamber
Pipe material and pipe diameter
Stainless steel:
SS50:
DN 50 (2")
SS65:
DN 65 (2 1/2")
SS80:
DN 80 (3")
SS100: DN 100 (4")
SS150: DN 150 (6")
SS200: DN 200 (8")
Polyethylene:
PE63:
D63 mm (2")
PE75:
D75 mm (2 1/2")
PE90
D90 mm (3")
PE110:
D110 mm (4")
PE160: D160 mm (6")
Installation type
Auto coupling:
A50:
DN 50 pump connection
A65:
DN 65 pump connection
A80:
DN 80 pump connection
A100:
DN 100 pump connection
A150:
DN 150 pump connection
A200:
DN 200 pump connection
Pump type
SEG:
SEG and SEG AUTOADAPT
DP/EF:
DP (0.6 - 1.5 kW) / EF
DP/SL:
DP (2.6 kW) / SL1.50.65 / SLV.65.65
SE/SL:
SE/SL
S:
S-pump

Pumping station systems

Selection of products

3. Selection of products
Ordering a pumping station
When ordering a Grundfos GS.S or GS.G pumping
station, take the following into consideration:
pump type (possible custom-built variant)
pipe material
pit diameter and depth
insulation of the pit (optional)
valve chamber (optional)
accessories such as controllers.
You can configure the pumping station system in
Grundfos Product Center at www.Grundfos.com by
using the selection tool. In this case all the
requirements must be known.
Pump type
The pumping stations can be equipped with the
following pumps:
DP, EF and AUTOADAPT pumps (0.6 - 1.5 kW)
SL1, SLV and AUTOADAPT pumps (0.9 - 2.6 kW)
SEG and SEG AUTOADAPT grinder pumps (0.9 - 4.0
kW)
SE, SL pumps (0.9 - 30 kW)
S-pumps up to range 70 (up to 155 kW).
Note: Data for a specific pump can be found in the
pump data booklet or in Grundfos Product Center at
www.Grundfos.com.
For further info about Grundfos Product Center, see
page 42.
Pump installation
The pumps are installed on an auto coupling at the
bottom of the pit.
See section Installation on page 28.
Pipe material
Pipes are made of PE (polyethylene) or stainless steel
(SS, AISI 304). See section Other product variants on
page 16.
Pump pit
The pits come various sizes and with various standard
fittings. See section Dimensions on page 32 and
Starting frequency on page 32 to calculate the volume
needed.
Valve chamber
The valve chamber is separate pit that can be selected
to house equipment so that service personnel need not
enter the pit.

Pump controllers and level control systems


The following controllers are available for standard
pumps:
Dedicated Controls (DC, DCD). See page 23.
LC and LCD 108 operated by float switches. See
page 24.
CU 100 (optional). See page 25.
The following controllers are available for AUTOADAPT
pumps:
Built-in controller. See page 26.
Grundfos CIU. See page 26.
Grundfos GO. See page 26.
For pump controllers, see section Pump controllers on
page 23 or in Grundfos Product Center at
www.Grundfos.com.
Accessories
Depending on the installation type, accessories may
be required. For selection of the correct accessories,
see section Pump controllers on page 23.
Note: Some of the accessories can be fitted from
factory. Contact Grundfos.

Pumping station systems

Selection of products

Selection tool

TM06 3497 0415

You can find the selection tool PUMPING STATION


CREATOR in Grundfos Product Center at
www.Grundfos.com.

Fig. 4

Selection tool in Grundfos Product Center

1. Input your requirements


Here you enter information about flow rate, head,
number of pumps and operating mode. This
ensures we offer the right pump for the task.
Information about the depth of the lowest inlet to
the pumping station is also required to get some
good suggestions for solutions.
The selection tool offers a list of pumps from which
you can select the pump required.
2. Select a solution
Here a number of possible solutions are presented,
and you can select the one that fits your
requirements.
3. Configure & customize
Here you can make the detailed configuration of the
selected solutions. Drawings of the selected
solution are presented.
4. Pick your accessories
Here you can select accessories for your
customised solution.
5. Print or e-mail your order
Here the final solution is presented as a CAD
drawing that can be downloaded. Specification
reports for the customised solution can be
generated, printed and sent to Grundfos.
This is the information Grundfos needs to give you
a quotation and lead time for delivery.

Pumping station systems

CE mark

4. CE mark
Pumping station
The pumping stations are CE-certified modules. The
declaration of performance is in accordance with
Annex III of Regulation (EU) No 305/2011
(Construction Product Regulation).
Pumps and controllers
Depending on the pumps and controllers selected, the
pumping stations are in accordance with one or
several of the following directives:
EMC Directive (2004/108/EC)
Low Voltage Directive (2006/95/EC)
ATEX Directive (94/9/EC)
Machinery Directive (2006/42/EC).
The declaration of conformity can be found in the
installation and operating instructions for the products.
CE-certified complete system
The standard range in Grundfos Product Center makes
it possible to obtain the EC declaration of conformity in
accordance with the Machinery Directive (2006/42/EC)
EN ISO 12100:2010.
Other main approvals and standards
EN12050-1 and EN 12050-2
Wastewater lifting plants for buildings and sites.
Principles of construction and testing. Lifting plants
for wastewater containing faecal matter.
EN 752
Drain and sewer systems outside buildings
EN 124
Gully tops and manhole tops for vehicular and
pedestrian ares. Design requirements, type testing,
marking and quality control.
EN 1917:2002
Concrete manholes and inspection chambers,
unreinforced, steel fibre and reinforced.

Pumping station systems

Product range

5. Product range
Pipes
Pipe variants
Pumping stations have three main pipe variants:
Goose neck (GC), common. See fig. 5.
Direct outlet (DC), common. See fig. 6.
Valve chamber (VC). See fig. 7.
Custom-made pipes are available on request. Contact
Grundfos.
Goose neck, polyethylene (PE)

GC, pipe system with goose neck

Fig. 6

DC, pipe system with direct outlet

TM06 2931 4814

Fig. 5

TM06 3848 1015

TM05 3319 1112 - TM06 3577 0615

Goose neck, stainless steel (SS)

Fig. 7

VC, valve chamber (no valves inside the pumping


station)

Pumping station systems

Product range

Pipe sizes
Pipes are offered in stainless steel (SS) or
polyethylene (PE). Some pit sizes are not available
with all variants. See section Pipe variants on page 9.
Stainless steel, SS - AISI 304
Pit diameter
[mm]
Pipe size

DN
DN
DN
DN
DN
DN
DN
*

50
65
80
100
150
200
250

1200-1400

1600-1800

2000-2200

GC

DC

VC

GC

DC

VC

3000

GC

DC

VC

GC

DC*

VC

This variant is also applicable for pits with three pumps.

Polyethylene, PE
Pit diameter
[mm]
Pipe size

D63
D75
D90
D110
D160

10

1200-1400

1600-1800

2000-2200

GC

DC

VC

GC

DC

VC

3000

GC

DC

VC

GC

DC

VC

Pumping station systems

Direction of outlet
The direction of the outlet depends on the diameter of
the pit and the pipe type. The outlet is always shown
with either degrees or time o'clock.

Product range

Polyethylene pipes (PE)


In pits with PE pipes and a diameter up to 3000 mm
the direction of the outlet is always 0 .
0 (0:00 / 12:00)

Stainless-steel pipes (SS)

TM06 3336 5114

Pits with a diameter up to 3000 mm and stainless-steel


pipes can be delivered with VC, DC and GC pipes. The
pipes determine the direction of outlet. See figures 8
and 9.
0 (0:00 / 12:00)

TM06 3419 0215

Fig. 11 Direction of outlet of pits up to 3000

Direction of outlet of a 2-pump installation, VC


pipes (valve chamber)

270
(9:00)

Fig. 9

90
(3:00)

TM06 3513 0615

Fig. 8

Direction of outlet of 3000 pits with DC and GC


pipes

A = xxx 50

Pipes
[DN]

A
[mm]

250 / 300
250 / 250
200 / 250
200/ 200
150 / 200
150 / 150
100 / 150
100 / 100
80 / 100
80 / 80

510
485
502
475
475
450
450
390
390
370

TM06 3912 1215

Figure 10 shows the offset of 3000 pits.

Fig. 10 Offset

Pits with stainless-steel pipes and a diameter of 1200


to 2200 mm can be delivered with VC, DC and GC
pipes. The outlet is always 0 . See fig. 11.

11

Pumping station systems

Product range

Pumping stations and pipe variants


Pumping stations come in various diameters and with
a number of pump and pipe combinations.
Not all pump variants are available across the ranges.
For more information, contact Grundfos.
S-pumps are available from range 50 to 70 (up to 255
kW) in S1, S2 and SV variants.

DN 50 stainless-steel pipes and D63 PE pipes


DN 40 pumps are only available with DN 50 pipes.
Pump
type

Installation type*

Pump with DC or VC pipes


Pump with GC pipes
Pump with DC or VC pipes + small
screen basket

SEG, DP, EF, AUTOADAPT

Pump with GC pipes + small screen


basket
Pump with DC or VC pipes + big
screen basket
Pump with GC pipes + big screen
basket
Pump with DC or VC pipes + EN 124
cover, 600 mm
Pump with GC pipes + EN 124
cover, 600 mm
Pump with DC or VC pipes + EN 124
cover, 800 mm
Pump with GC pipes + EN 124
cover, 800 mm
Pump with DC or VC pipes + small
baffle plate
Pump with GC pipes + small baffle
plate
Pump with DC or VC pipes + big
baffle plate
Pump with GC pipes + big baffle
plate
*

12

Pipe
material
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE
SS
PE

Pit diameter
[mm]
1200

1400

1600

1800

For more information about pipes, see section Other product variants on page 16.

2000

2200

3000
2 pumps

3000
3 pumps

DN 65 and DN 80 stainless-steel pipes and D75 and D90 PE pipes


Pump
type

Installation type*

1200

1400

1600

1800

2000

2200

3000
2 pumps

3000
3 pumps

SS

1)

4)

PE

1)

SS

1)

PE

1)

SS

2)

PE

2)

Pump with GC pipes + small screen


basket

SS

2)

PE

2)

Pump with DC or VC pipes + big


screen basket

SS

PE

Pump with GC pipes + big screen


basket

SS

PE

Pump with DC or VC pipes + EN 124


cover, 800 mm

SS

1)

3)

3)

1)

PE

1)

3)

3)

1)

SS

1)

3)

3)

1)

1)

3)

3)

1)

1)

Pump with DC or VC pipes


Pump with GC pipes
Pump with DC or VC pipes + small
screen basket

SE1, SL1, SLV, SEV


S-pumps, range 50

Pit diameter
[mm]

Pipe
material

Pump with GC pipes + EN 124


cover, 800 mm

PE

Pump with DC or VC pipes + small


baffle plate

SS

PE

1)

3)

Pump with GC pipes + small baffle


plate

SS

1)

3)

PE

1)

3)

Pump with DC or VC pipes + big


baffle plate

SS

1)

PE

1)

SS

1)

PE

1)

Pump with GC pipes + big baffle


plate

Product range

Pumping station systems

4)

4)

4)

4)

For more information about pipes, see section Other product variants on page 16.
Only SE and SL pump variants are available. Contact Grundfos.
2) Only available for SE1.50.65, 80.22, 30.2, and SL1.50.65, 80.22 and 30.
3)
Only available for SE and SL.
4) Only available with DN 80 or D90 DC pipes.
1)

13

Pumping station systems

Product range

DN 100 stainless-steel pipes and D110 PE pipes


Pump
type

Installation type*

Pit diameter
[mm]

Pipe
material
1600

1800

2000

2200

3000
2 pumps

3000
3 pumps

SS

PE

SS

PE

Pump with DC or VC pipes + small


screen basket

SS

PE

Pump with GC pipes + small screen


basket

SS

PE

Pump with DC or VC pipes + big


screen basket

SS

PE

Pump with GC pipes + big screen


basket

SS

PE

Pump with DC or VC pipes + EN 124


cover, 800 mm

SS

3)

PE

3)

Pump with GC pipes + EN 124


cover, 800 mm

SS

3)

PE

3)

Pump with DC or VC pipes + small


baffle plate

SS

2)

2)

PE

2)

2)

Pump with GC pipes + small baffle


plate

SS

2)

2)

PE

2)

2)

SS

1)

1)

4)

PE

1)

1)

4)

SS

1)

1)

PE

1)

1)

1200
Pump with DC or VC pipes

SE1, SL1, SLV, SEV


S-pumps, ranges 50 and 54

Pump with GC pipes

Pump with DC or VC pipes + big


baffle plate
Pump with GC pipes + big baffle
plate
*

1400

For more information about pipes, see section Other product variants on page 16.
Limited range of SE and SL pump variants available. Contact Grundfos.
2) Not available for SE1.100.100.40, 55 and 75.4, and SL1.100.100.40, 55 and 75.
3)
Limited range of SE and SL pump variants available. Not available with S-pumps. Contact Grundfos.
4) Only available with DC pipes.
1)

14

4)

4)

4)

DN 150 stainless steel-pipes and D160 PE pipes


Pump
type

Installation type*

Pump with DC or VC pipes

Pit diameter
[mm]
1200

1400

1600

1800

SS

2000

2200

3000
2 pumps

3000
3 pumps

3)

PE

SS

1)

1)

PE

1)

1)

Pump with DC or VC pipes + small


screen basket

SS

PE

Pump with GC pipes + small screen


basket

SS

1)

2)

PE

1)

2)

Pump with DC or VC pipes + big


screen basket

SS

PE

Pump with GC pipes + big screen


basket

SS

1)

2)

PE

1)

2)

Pump with DC or VC pipes + small


baffle plate

SS

PE

Pump with GC pipes + small baffle


plate

SS

1)

1)

PE

1)

2)

Pump with DC or VC pipes + big


baffle plate

SS

PE

Pump with GC pipes + big baffle


plate

SS

2)

PE

2)

2200

3000
2 pumps

3000
3 pumps

Pump with GC pipes

SE1, SL1, SLV, SEV


S-pumps, ranges 50, 54 and 62

Pipe
material

Product range

Pumping station systems

3)

3)

3)

3)

For more information about pipes, see section Other product variants on page 16.
In SE and SL ranges only available for SE1.100.150.40 and 55.4, and SL1.100.150.40 and 55.
2) In SE and SL ranges only available for SE1.100.150.40 and 55.4, and SL1.100.150.40, 55 and 75.
3)
Only available with DC pipes.
1)

DN 200 and DN 250 stainless-steel pipes


Pump
type

Installation type*

Pit diameter
[mm]

Pipe
material

SE1, SL1, SLV, SEV


S-pumps, ranges 54, 66 and 70

1200

*
1)

1400

1600

1800

2000

Pump with DC or VC pipes

SS

1)

Pump with DC or VC pipes + small


screen basket

SS

1)

Pump with DC or VC pipes + big


screen basket

SS

1)

Pump with DC or VC pipes + small


baffle plate

SS

1)

Pump with DC or VC pipes + big


baffle plate

SS

1)

For more information about pipes, see section Other product variants on page 16.
Only available with DN 200 pressure flange and for DC pipes.

15

Pumping station systems

If you cannot find a pumping station that meets your


requirements, please contact your local Grundfos
company. We have other ranges of prefabricated
pumping stations, but they vary from region to region.
For large prefabricated pumping stations, please see
Grundfos Product Center at www.Grundfos.com or
contact your local Grundfos company. We offer a wide
selection in versions up to 3 metres in diameter and 12
metres deep in both glass-fibre-reinforced plastic and
polyethylene. See examples in figures 12 to 14.

TM06 3304 5114

Product range

Other product variants

TM06 3302 5114

Fig. 14 Pumping station with service cabin

TM02 9363 2404

Fig. 12 Custom-made pumping station with separate pits

TM06 3303 5114

Fig. 15 Small PUST pumping stations (D400 to 1700, PE)

Fig. 13 Pumping station with dry-installed pumps,


including dry and wet chambers (INTEGRA)

16

Pumping station systems

Construction

6. Construction
Pumping station
2

7
1

10
11

12

14

13
18
15

20

17

TM06 3382 0115

16

19

Fig. 16 Grundfos pumping station

Components and material specification


Pos.

Component

Material

Cover

Glass-fibre-reinforced plastic
(GRP)

Cover approved for


traffic

Concrete ring and cast-iron hatch

Hatch

Aluminium

Hatch insulation

Styrofoam

Gas springs

Pos.
11

Component
Inlet

Material
Stainless steel
Plastic

Screen basket

Stainless steel

Baffle plate

Stainless steel

13

Guide pipes for screen


basket

Stainless steel

14

Piping

Stainless steel

15

Lifting chain

Galvanised steel

12

Stainless steel
Polyethylene

Safety grid

Venting pipe

Stainless steel

16

Pump

Handrail

Stainless steel

17

Auto coupling

Epoxy-coated cast iron

Outlet

Stainless steel

18

Level sensor

Ladders and ladder


supports

Stainless steel

19

Base plate for pumps

Aluminium

10

Service platform

Stainless steel

Stainless steel

Aluminium

17

Pumping station systems

Construction

Valve chamber
3
2

4
7
6

1
8

Fig. 17 Grundfos valve chamber

Components and material specification


The valve chamber always includes a drainage pipe
leading to the pumping station. The valve chamber is
also available in a version insulated with PE foam.
Pos.

Component

Material

Valve chamber

Cover

Glass-fibre-reinforced
plastic (GRP)

Hatch

Aluminium

3
4

18

Hatch insulation

Styrofoam

Isolating valve

Epoxy-coated cast iron

Non-return valve

Epoxy-coated cast iron

Ladders

Aluminium

Pipes

Stainless steel

Drainage pipe

Plastic

Isolating valve

Plastic

TM06 3288 5014

Pumping station systems

TM06 1990 3514

TM06 4010 1415

Construction

Pumping station variants

Fig. 20 Pumping station (3000 mm) with three pumps,


direct outlet, separate service hatch and fixed
service platform

TM06 4009 1415

TM06 2932 4814

Fig. 18 Pumping station with two pumps and goose neck


outlet

Fig. 21 Pumping station with two pumps, direct outlet and


separate valve chamber

Fig. 19 Pumping station with two pumps, direct outlet and


liftable service platform

19

Pumping station systems

Construction

Covers

Covers approved for traffic

All pumping stations are equipped with a cover that


can be locked and has a safety grid. The cover type
depends on the size of the pumping station and the
installation site.

The covers come in the two versions shown below and


are approved according to EN 124, Class D.
Version 1, cover with concrete ring
The cover has a concrete ring, an extended cover and
a steel hatch. The cover can be made with (1a) or
without (1b) a floating cover. See fig. 24.

Standard covers
Standard covers are made of fibre-glass-reinforced
plastic and have an aluminium hatch. The number of
hatches depends on the pit diameter:
one hatch for 1200-2200 pits
two hatches for 3000 pits.

1a. Concrete ring without blacktop

1b. Concrete ring with blacktop

TM06 1685 2614

Blacktop

Fig. 22 Aluminium hatch and safety grid (1200-2200)

Floating cover

TM06 3915 1215 - TM06 3914 1215

Note: Aluminium hatches are not approved for traffic.

Fig. 24 Cover with concrete ring

For more information about of concrete rings for


covers approved for traffic, see section Dimensions of
concrete covers on page 38.
Version 2, cover with air space
The cover has a concrete ring and a steel hatch. The
cover is available for all pit sizes as an optional cover.

TM06 1686 2714

Air space between concrete


ring and pit

TM06 3457 0415

Fig. 23 Service hatches (3000)

Fig. 25 Cover approved for traffic and with air space

For more information about of concrete rings for


covers approved for traffic, see section Dimensions of
concrete covers on page 38.

20

Pumping station systems

Construction

Venting pipes
Venting pipes can be either top-mounted or sidemounted.

TM06 3446 0415

TM06 1683 2614

90

Fig. 26 Pit with top-mounted venting pipe

TM06 1687 2714

TM06 1684 2614

Fig. 28 Liftable service platform

Fig. 27 Pit with side-mounted venting pipe

Control cabinets
Control cabinets can be installed as follows:
on the cover of the pumping station. See fig. 48 on
page 31.
on a separate concrete plate next to pumping
station
on the wall of a building etc.

Fig. 29 Fixed service platform

Baffle plates
The baffle plate slows the incoming flow of liquid and
prevents splattering inside the pit.

Service platforms

Pit diameter
[mm]

TM06 3445 0415

Service platforms enables valve maintenance inside


the pumping station. The platforms are made of
aluminium.
Platform

1200

Not available

1400-2200

Liftable

3000

Fixed installation

Fig. 30 Baffle plate

Note: The service platform is for one person only.


The liftable service platform is equipped with joint
hinges so that it can be lifted manually, for instance
when the pump is to be lifted out of the pit. Lifted up,
the platform rests against the wall and needs no
locking during the service actions.

21

Pumping station systems

The screen basket removes materials such as stones


and branches from the incoming flow of liquid.

TM06 3515 0615

Construction

Screen baskets

Fig. 31 Screen basket


Basket dimensions Size of screen holes
HxLxW
HxL
[mm]
[mm]

Size
Small
Large

453 x 326 x 206


794 x 650 x 306

185 x 45
350 x 45

Level controllers
Float switches

TM04 3454 4438 - TM02 8960 1204

Float switches can be installed on a tube outside the


pumping station. This ensures easy adjustment of the
float switches. See fig. 32. Two to four float switches
are used together with LC or LCD controllers.

Fig. 32 Adjustment of float switches


A

Min. 300 mm

50-100 mm

Deactivation range: 110 mm

Distance B must not be too big as otherwise the float


switch may get stuck in other parts of the installation.
Pressure transducers
If a pressure transducer is used for level detection,
install it in the protective pipe in order to prevent
contamination and deposits.

22

Pumping station systems

Accessories

7. Accessories
Pump controllers
IO 113 module

Dedicated Controls

The IO 113 module is a protection module for Grundfos


wastewater pumps.
The module has inputs for digital and analog pump
sensors and can stop the pump if a sensor indicates a
pump fault.
The module is connected to the Dedicated Controls
system and allows advanced monitoring functions:
motor temperature
moisture in motor
water in oil or water in air
insulation resistance.

Grundfos Dedicated Controls is a control system that


can control and monitor one to six Grundfos
wastewater pumps and a mixer or a flush valve.
Dedicated Controls is used in installations requiring
advanced control and data communication.
Main components of the Dedicated Controls system:
CU 362 control unit
IO 351B module (general I/O module).
Dedicated Controls is available either as separate
components or as control cabinets.
The control system can be operated by the following:
float switches
a level sensor
a level sensor and safety float switches.
The control cabinet is available for the following pump
sizes and starting methods:
pumps up to and including 9 kW, direct-on-line
starting
pumps up to and including 30 kW, star-delta starting
pumps up to and including 30 kW, soft starter.
The separate control unit and modules can be built for
practically any size of system.

SM 113 module
The SM 113 module is used for collection and transfer
of sensor data. The module works together with the IO
113 through power line communication using the
Grundfos GENIbus protocol.
The module can collect data from these devices:
3 current sensors, 4-20 mA
3 PT1000 thermal sensors
1 thermistor circuit (3 sensors in series)
1 digital input.

Level controllers

Gr-1016087

Grundfos offers a wide range of pump controllers to


keep a watchful eye on liquid levels in the wastewater
collecting pit, ensuring correct operation and
protection of the pumps.
Controller ranges:
Dedicated Controls: DC and DCD
LC and LCD level controllers
CU 100 control box.
The DC, LC and CU 100 are designed for one-pump
installations, and the DCD and LCD are designed for
two-pump installations.
Fig. 33 Dedicated Controls control cabinet

23

7
The DC and DCD control cabinets can be fitted with
various units:
The CU 362 control unit, which is the "brain" of the
Dedicated Controls system, is fitted in the cabinet
front. The CU 362 can be fitted with one of the
Grundfos CIM communication modules mentioned
below, depending on the monitoring needs or the
SCADA system:
The CIM 200 is a communication module used for
the Modbus RTU fieldbus protocol.
The CIM 250 is a communication module used for
GSM/GPRS communication. The CIM 250
establishes communication between the CU 362
and a SCADA system, thereby allowing the
application to be monitored and controlled
remotely. This module also offers SMS
messaging, for example status and alarm
messages.
The CIM 270 is a communication module for the
Grundfos Remote Management system (GRM).
The CIM 270 establishes communication between
the CU 362 and the GRM, thereby allowing the
application to be monitored and controlled
remotely.
The CIM 050 GENIbus module is fitted in a
Grundfos product. The CIM 050 enables data
transmission between a GENIbus network and a
Grundfos product.
The CIM 500 is a Grundfos communication
interface module used for data transmission
between an industrial Ethernet network and a
Grundfos product. The CIM 500 communicates
with the CIU 902.
The IO 351B is a general I/O module and
communicates with the CU 362 via GENIbus.
The MP 204 motor protector (optional), which
provides many electrical status values, for instance
voltage, current, power, insulation resistance and
energy. The MP 204 offers better protection of the
pumps than a conventional motor protection device.
The CUE or VFD (optional) is either a Grundfos
variable-frequency drive or a general variablefrequency drive. The variable-frequency drive offers
better pump protection and a more steady flow
through the pit pipes so that the pumps are treated
well and the energy consumption is kept at a
minimum.
For further information, see the data booklet or
installation and operating instructions for Dedicated
Controls in Grundfos Product Center at
www.Grundfos.com.

LC and LCD
The Grundfos LC and LCD ranges of level controllers
comprise three series with a total of six variants:
LC and LCD 107 operated by air bells
LC and LCD 108 operated by float switches
LC and LCD 110 operated by electrodes.
All controllers are ideally suited for applications
requiring up to 11 kW motors for direct-on-line starting.
Features and benefits
Control of one pump (LC) or two pumps (LCD).
Automatic alternating operation of two pumps
(LCD).
Automatic test run (prevents shaft seals from
becoming jammed in the event of long periods of
inactivity).
Water hammer protection.
Starting delay after power supply failure.
Automatic alarm resetting, if required.
Automatic restarting, if required.
Alarm outputs as NO and NC.

LCD 110

TM04 2360 2408

Accessories
24

Pumping station systems

Fig. 34 LCD 110 for two-pump installations

When an SMS module (optional) is fitted in an LC or


LCD controller, it acts as a time recorder for the
pumps, and when programmed (using an ordinary
mobile phone with text messaging facility), it can send
text messages containing "high-level alarm", "general
alarm", information about operation and the number of
times the pump has started. The SMS module is also
available with battery and can thus send text
messages that will inform you of power failure and
when the power has been restored.
For further information, see the data booklet or
installation and operating instructions for the LC and
LCD controllers in Grundfos Product Center at
www.Grundfos.com.

CUE frequency converter

The CU 100 control box is designed for the starting,


operation and protection of small wastewater pumps.
The control box is available in several variants which
can be used for the following:
single-phase pumps (up to and including 9 A)
three-phase pumps (up to and including 5 A).
The control box is also suitable for the following:
start/stop by means of a float switch
manual start/stop.
During manual operation, the pump is started and
stopped with the on/off switch.
During automatic operation, the float switch will start
and stop the pump.
For further information, see the installation and
operation instructions for the CU 100 in Grundfos
Product Center at www.Grundfos.com.

Grundfos CUE is complete range of external frequency


converters designed for speed control of a wide range
of Grundfos pumps.

Gr-1015227

CU 100

Accessories

Pumping station systems

TM02 6459 0703

Fig. 36 CUE

CUE has a built-in PI controller and offers the same


functionality and user-interface as Grundfos S-pumps.
CUE solutions can thus be seen as an extension to the
S-pump range.
The CUE offers following benefits:
speed control of pumps up to 250 kW (also pumps
installed in potentially explosive environments)
2 alarm outputs (C, NO, NC)
1 sensor (4-20 mA)
2 PT100 or PT1000 sensors.

Fig. 35 CU 100

25

Pumping station systems

Grundfos CIU
The Grundfos CIU unit is used as a communication
interface between a Grundfos product and a main
network. The CIU unit is used as an interface for
following:
Configuration of pump parameters required for
water level control.
Online monitoring of pit and pump values.
Manual water level control (forced start/stop).
Collection of measured and logged data that are
valuable for pump service and pit optimisation.
The CIU unit is designed for use together with
Grundfos AUTOADAPT pumps. Communication can be
established with the Grundfos GO or by using the main
network interface of the CIU unit.
Available CIU units:
CIU 152 PROFIBUS DP
CIU 902 (without CIM module)
CIU 202 Modbus
CIU 252 GSM, GPRS
CIU 272 GRM (Grundfos Remote Management).
The CIU unit incorporates one or two modules:
multipurpose I/O module with I/O functionality, IR
communication interface and power line
communication.
CIM module (optional).
For further information about the CIM module fitted,
see the installation and operating instructions for the
CIM module.
If a CIM module is fitted in the CIU unit, the sensors
connected to the digital input of the I/O module can be
remotely monitored from a centrally located SCADA
system.
Grundfos GO
The Grundfos GO is designed for wireless IR
communication with Grundfos products. The Grundfos
GO can communicate with the AUTOADAPT pumps via
a CIU unit.
The Grundfos GO is to be regarded as an ordinary
service and measuring tool and is therefore designed
to withstand wear and stress from everyday use.

26

ADC
The ADC fuse box is designed for the protecting the
power supply for small wastewater pumps.

Gr-1016011

Accessories

AUTOADAPT pumps

Fig. 37 ADC

The fuse box enables communication with the


following:
Grundfos Remote Management, GRM
Grundfos GO
SCADA.
The fuse box can be used with the following:
one-pump installation with or without CIU (1
two-pump installation with or without CIU (1
CIU units
CIU 202 Modbus RTU (2
CIU 272 GRM (2
CIU 902 (2
CIU 252 GSM complete (2
optional service socket 230 V (3 / 50 Hz (2
optional socket for PC Tool link box (2
optional fault indicator light mounted on top (2
optional audio alarm, 100 dB (2.
(1

With a CIU unit, a CIM module is needed.


Must be ordered with the control box.
(3
The modules come as two parts and must be assembled.
(2

For further information, see the installation and


operation instructions for the ADC in Grundfos Product
Center at www.Grundfos.com.

Name

DC

DCD

LC

LCD

CU 100

AUTOADAPT

CIU

Mixer

Backup battery

Float switches

Application
One pump
Two pumps

Accessories

Pumping station systems

Level sensor
7)

Electrodes

7)

Air bells

7)
3)

7)

Pressure transducer

Ultrasonic sensor

7)

Analog level sensor with safety float


switches

7)

Starting method
Direct-on-line starting (DOL)

Star-delta starting

Soft starter

Start and stop of pump(s)

Basic functions

Pump alternation

High-level alarm

Dry-running alarm

Flow measurement (calculated or via


flow sensor)

Pump statistics

4)

Conflicting levels alarm

Start and stop delays

Advanced functions

Motor temperature sensor

Test run/anti-seizing

Daily emptying (once a day)

Water-in-oil sensor input

2)

2)

2)

2)

4)

Communication
SMS messaging
SCADA communication GSM/GPRS

1)

1)

2)
5)

User interface

1)
2)
3)
4)
5)
6)
7)

Level indication

Graphical display

PC Tool WW Controls

6)

6)

If an SMS module is fitted.


If a CIM 252 GSM/GPRS module is fitted in the CU 362.
Built-in pressure transducer and dry-running sensor.
Built-in, but a Grundfos CIU unit is required to get access to data or setting of parameters.
Modbus, GSM, GPRS, SMS and GRM options.
When using Grundfos GO.
Inputs for external sensors (NO or NC).

27

Pumping station systems

Installation

8. Installation
Local regulations and legal requirements must always
be observed. For further information, see the
installation and operating instructions for the pumping
station.
Note: Some pits come without the pump installed. For
installation and startup, see the installation and
operating instructions for the pump.

When lifting the pit, secure the pit with approved


straps. See fig. 40. The customer must provide the
appropriate lifting equipment.

Transportation and handling

TM06 1233 1914

The size of the transportation vehicle must be


calculated in advance to make sure that it is suitable
for the pit. Use the safety dimensions in the table
below. The required safety dimensions are based on
the pit dimensions. See fig. 38.

TM06 3580 0615

Fig. 40 Lifting straps

Fig. 38 Safety dimensions


Dimension
A
B
C

Safety dimensions
Pit length plus 400 mm
Pit diameter plus 200 mm
Pit diameter plus 400 mm

TM06 1232 1914

Note: In case of special variants, such as an extra long


inlet or outlet pipes outside the pit, the size of
transportation vehicle needs to be redefined.
The pit must be transported in a horizontal position
and anchored to the transport vehicle. Accessories, if
any, must be secured inside the pit.

Fig. 39 Lifting the pumping station from the lorry

28

Acceptance inspection
After transportation and before installation, the
pumping station must be inspected by the customer.
The inspection must include the following:
Check the pumping station for transport damage.
Contact the transporter immediately if you detect
any damage.
Check that the products delivered correspond to the
order.
Check the positions and sizes of fittings.
Retighten various connections, as they may have
become loose during the transport.
Check that all valves, except the draining valve in
the valve chamber, are open.
Check other equipment such as venting pipes.

Installation of pumping station

Foundation slab
The bottom of the excavation hole must be levelled
and filled with a foundation layer, if needed, before the
slab is lowered into the excavation hole.

Installation

Pumping station systems

Fig. 41 Schematic installation drawing


Pos.

TM06 1237 2514

TM06 1848 3214

Fig. 42 Lowering the foundation slab

For more information about the foundation slab, see


section Dimensions of the foundation slab on page 35.

Description

Foundation layer

Concrete foundation slab

Backfill, compacted in layers of maximum 50 cm

Distance of 50 cm from cover where heavy loads must


not occur

Installation to excavation hole


The walls of installation excavation hole must be
secured so that there is no risk of lapse of ground
during installation. The excavation hole must be
designed according to local regulations.

Pumping station
The surface of the foundation slab must be cleaned
before the pit is lowered onto it. If a pit is to be installed
at temperatures below 0 C, slacken all bolts of the
flange and retighten them when the pit has been
installed. In this way, stress in the pipes is prevented.
Location of inlet
The inlet can be located 360 around the pit, except
when you have selected a screen basket or baffle
plate. In these cases the selection tool PUMPING
STATION CREATOR automatically informs you if the
inlet is placed in an incorrect position. See page 7.
In any case, the inlet is designed to be below the
service platform.

29

Pumping station systems

Installation

Pit

Cover approved for traffic

When lowering the pit, make sure that the flanges are
in the right direction according to inlet and outlet pipes.
The pit is locked to the foundation slab by means of
mounting brackets and anchor bolts. See section
Dimensions of the foundation slab on page 35.

The maximum angle of inclination for the cover is 25 .


The installation method depends on the cover version.
See the descriptions below.
Version 1, cover with concrete ring
The backfill must be compacted carefully so that it
does not harm the top of the tank. The fraction size
under the cover and near the top of the pumping
station must be between 2 and 20 mm. The cover is
lowered onto the compacted backfill. A blacktop can be
made on the ring. See fig. 45.
Note: The pit comes with a 500 mm collar that must be
cut to the right length on the installation site.
Note: The pit must not support the concrete ring.
Fraction size 2-20 mm

Blacktop (optional)

Thickness of slab: 150-250 mm

350-250 mm

500 mm
(factory
height)

Fig. 43 Installing the pipes and the mounting bracket

In pits with diameters of 2.0, 2.2 and 3.0 m, discharge


pipes sizes above DN 150 and with two holes in the
bottom of the pit, fill the hollow space in the bottom of
the pit with concrete to avoid vibrations. See fig. 44.

TM06 3921 1215

TM061239 1914

Compacted layers

Fig. 45 Installation of cover slab with concrete ring

Dimensions for of the concrete cover slab, see section


Dimensions of concrete covers on page 40.
Version 2, cover with air space
The traffic cover is lowered on the pit when the backfill
has been compacted to the top of the pit. The air space
between the cover and pit must be 150 mm. See fig.
46.
The backfill for the cover can be made with same
instructions as those for the pit.
Ground level

Cover

Concrete slab

TM06 4359 2115

Air space: 150 mm

Pit 1200-3000

Fig. 44 How to fill the hollow space with concrete

Valve chamber

Compacted
layers

The same installation instructions apply to the valve


chamber as those for the pit.
Fig. 46 Cover with air space

Dimensions of the concrete cover slab, see section


Dimensions of concrete covers on page 40.

30

TM06 3575 0615

Top level of the pit

Backfill

Electrical installation

The backfill gravel or sand must have an even fraction


size. The maximum fraction size is 32 mm. The backfill
material must not contain any stones larger than the
maximum fraction size.
When filling a hole in the winter, the filling material
must be completely melted.
Carry out backfill layer by layer in such a way that the
height of a layer never exceeds 50 cm. See fig. 47.
Note: Compact the backfill under the inlet and outlet
pipes properly so that they are not exposed to
downward loads when the backfill settles. Plate
compactors must not be used at a distance of less than
30 cm from the pit wall.

See the installation and operations instructions for the


pump and the control system.

Startup

Installation

Pumping station systems

See the installation and operating instructions for the


pump and the controller.
Note: The controller must not be installed in the pit.
Note: The pump must not run dry; only when checking
the direction of jerk.

Control cabinet
The control cabinet is to be installed on top of the
pumping station into the raised place that has been
served for it. Control panels are installed inside the
cabinet. Make sure that the electrical connection is
made according the local regulations.

Door is in straight line


and open properly

Fig. 47 Compacted layers of maximum 50 cm

Pump
See the installation and operation instructions for the
pump.
Note: The pump must be lowered carefully into the pit
in order to avoid damage to pump and pit.

Installation of level controller


See the installation and operating instructions for the
controller.

Other accessories
Not all accessories are factory-fitted and need to be
installed when the pit has been installed and the
backfill made. Examples of accessories are venting
pipe and control panel.

Washers

TM06 3376 5214

Maximum 50 cm

TM06 3352 5214

Silicon sealing

Fig. 48 Control cabinet

Commissioning
A commissioning inspection must be done at the first
startup. The inspection must include the possible
failure report that must be delivered to Grundfos.
The inspection must include the following:
wiring connection
level controller installation and operation
pump installation and operation
cable connection
necessary adjustments
overcurrent relay setting and testing.
In case of guaranty issues, the commissioning
inspection report must be available.

Maintenance
See the installation and operating instructions for the
pump and the controller.
It is important to secure the pumping station cover so
that unauthorised persons cannot remove it.

31

Pumping station systems

Dimensions

9. Dimensions
Starting frequency
In a pumping station, the water volume comprises the
volume below the lowest pump stop level and the
pumpable volume above this level, fluctuating with
pump usage and incoming flow rate. The starting
frequency of the pumps depends on the available
pumpable volume and the incoming flow rate.
The starting frequency Z is a function of the ratio
between Qin/Q and Vh
Qin
Q

=
=

Vh

incoming flow rate [l/s]


pump capacity [l/s]
accumulated (pumpable) volume between
start and stop [m3].

Note: When the maximum incoming flow rate is equal


to the pump capacity, the pump runs permanently.
When the actual pump capacity for single-pump
operation is equal to the maximum peak inflow, Zmax,
will always appear when the inflow is half the pump
capacity.
Zmax: maximum number of starts per hour.
Zmax =

Q x 3.6
4 x Vh

Vh: necessary minimum accumulated volume between


start and stop.
Vh =

Q x 3.6
4 x Zmax

Sump volume
In installations where the expected maximum incoming
flow rate, Qin, is less than 60 % of the selected pump
capacity, the accumulated sump volume must be
chosen in such a way that there will be at least two
pump starts a day in order to prevent sedimentation in
the sump.

32

Pumping station systems

Dimensions

Dimensions of pumping station


B

G1

TM06 3238 5014

Fig. 49 Dimensional sketch

A
[mm]

B
[mm]

1200
1400
1600
1800
2000
2200
3000

570 x 840
725 x 940
880 x 1880
890 x 1280
1070 x 1400
1190 x 1400
1570 x 2200

B
(cover
approved for
traffic)

F
[mm]

Manhole
600/800

1430
1640
1834
2040
2263
2468
3285

G1
SS*

G1
PE*

G
SS
[ mm]

G
PE
[ mm]

DN 50-DN 80

D63-D90

DN 50-DN 300

D63-D315

DN 50-DN 100

D63-D110

DN 50-DN 400
DN 50-DN 450

DN 65-DN 150

D75-D160

DN 80-DN 250

D90-D160

H**
[mm]

1500-8000
D63-D400

DN 50-DN 600

* Material and pipe variants, see section Pipes on page 9.


** For higher variants (up to 12,000 mm), contact Grundfos.

Note: Safety dimensions for transportation are shown


in section Transportation and handling on page 28.

33

Pumping station systems

TM06 4285 1815

H1

Dimensions

Dimensions of valve chamber

D1
D2

Fig. 50 Dimensional sketch of valve chamber


H*
[mm]
1500
1500
1500
1500
1500
1500
1500
*

34

/
/
/
/
/
/
/

2000
2000
2000
2000
2000
2000
2000

Low chamber / high chamber.

H1*
[mm]

Pipe inlet size


[DN]

D1
[mm]

D2
[mm]

740 50 / 1240 50

DN 50
DN 65
DN 80
DN 100
DN 150
DN 200
DN 250

1400
1400
1400
1400
1400
2200
2200

1640
1640
1640
1640
1640
2468
2468

Pumping station systems

Concrete
Min. thickness of the concrete
on top of the reinforcement
Concrete exposure class
Reinforcement
Max. angle of inclination

A/6

A/6

2
G

Dimensions

Dimensions of the foundation slab


C40/50-2
35 mm
XC4
B500B
25

TM06 1991 3514 - TM06 3498 0615

Max. 25

600

D
1

B-80mm
2

Fig. 51 Foundation slab

Foundation slab
Dimension
A

Pit diameter
[mm]

Pit depth
[mm]

1000

1200

1400

1600

1800

2000

2200

3000

1500

1800

2100

2400

2700

3000

3300

4000

200

350
650
800
900
1000
1100
1200
1300
3325

< 3500
3500-6000
6000-7000
7000-8000
8000-9000
9000-10,000
10,000-11,000
11,000-12,000
-

200
200

200

200

200
250

1470

1680

1875

200
250
250

300

300

300

350

2080

2300

2510

35

Pumping station systems

Dimensions

Anchor bolts
The number of anchor bolts depends on the pit
diameter.
Number of anchor bolts based on the pit diameter
[mm]

Pit depth
[mm]

1000

1200

1400

1600

1800

2000

2200

3000

1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
9000
9500
10000
10500
11000
11500
12,000

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6

4
4
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
8
8
8

4
4
4
4
4
4
4
4
6
6
6
6
6
8
8
8
8
8
10
10
10
10

4
4
4
4
4
6
6
6
6
8
8
8
8
10
10
10
10
12
12
12
12
14

4
4
4
4
6
6
6
8
8
8
10
10
10
12
12
12
14
14
14
14
16
16

4
4
4
6
6
8
8
8
10
10
12
12
12
14
14
16
16
16
18
18
20
20

4
4
6
6
8
8
10
10
12
12
14
14
16
16
18
18
20
20
20
22
22
24

6
8
10
12
14
16
16
18
20
22
24
26
28
30
32
32
34
36
38
40
42
44

The angle (G) between the anchoring bolts is


calculated by dividing the installation circle (360 ) by
the number of bolts.
Reinforcement - main bars
Cells with grey colour shows the minimum amount of
reinforcement.
Slab width
[mm]

Pit depth
[mm]

1500

1800

2100

2400

2700

3000

3300

4000

< 3500
3500-6000
6000-7000
7000-8000
8000-9000
9000-10,000
10,000-11,000
11,000-12,000

T8cc200
T8cc200
T8cc200
T8cc200
T8cc200
T8cc200
T8cc200
T8cc200

T8cc200
T8cc200
T8cc200
T8cc200
T8cc200
T10cc250
T10cc250
T10cc250

T8cc200
T8cc200
T8cc200
T10cc250
T8cc150
T12cc300
T12cc250
T12cc250

T8cc200
T10cc250
T12cc300
T12cc300
T12cc250
T10cc150
T12cc300
T12cc250

T8cc200
T10cc200
T12cc250
T10cc150
T12cc250
T12cc250
T12cc300
T12cc250

T8cc200
T12cc250
T10cc150
T12cc250
T10cc150
T12cc200
T10cc150
T10cc150

T10cc300
T10cc200
T10cc200
T10cc150
T10cc150
T10cc150
T10cc150
T10cc150

T12cc250
T16cc200
T16cc200
T16cc150
T16cc125
T16cc125
T16cc100
T16cc100

Reinforcement - stirrups
Slab width
[mm]

Pit depth

36

[mm]

1500

1800

2100

2400

2700

3000

3300

4000

< 3500
3500-6000
6000-7000
7000-8000
8000-9000
9000-10,000
10,000-11,000
11,000-12,000

T8cc200
T8cc200
T8cc200
T8cc200
T8cc200
T8cc200
T8cc200
T8cc200

T8cc200
T8cc200
T8cc200
T8cc200
T8cc200
T10cc250
T10cc250
T10cc250

T8cc200
T8cc200
T8cc200
T10cc250
T8cc150
T12cc300
T12cc250
T12cc250

T8cc200
T10cc250
T12cc300
T12cc300
T12cc250
T10cc150
T12cc300
T12cc250

T8cc200
T10cc200
T12cc250
T10cc150
T12cc250
T12cc250
T12cc300
T12cc250

T8cc200
T12cc250
T10cc150
T12cc250
T10cc150
T12cc200
T10cc150
T10cc150

T10cc300
T10cc200
T10cc200
T10cc150
T10cc150
T10cc150
T10cc150
T10cc150

T12cc250
T16cc200
T16cc200
T16cc150
T16cc125
T16cc125
T16cc100
T16cc100

Lifting
Design weight of the slab
[kN]
(load factor 1.25)

Slab thickness
[mm]

1500

1800

2100

2400

2700

3000

3300

4000

200
250
300
350
650
800
900
1000
1100
1200
1300

14.1
17.6
21.1
24.6
45.7
56.3
63.3
70.3
77.3
84.4
91.4

20.3
25.3
30.4
35.4
65.8
81.0
91.1
101.3
111.4
121.5
131.6

27.6
34.5
41.3
48.2
89.6
110.3
124.0
137.8
151.6
165.4
179.2

36.0
45.0
54.0
63.0
117.0
144.0
162.0
180.0
198.0
216.0
234.0

45.6
57.0
68.3
79.7
148.1
182.3
205.0
227.8
250.6
273.4
296.2

56.3
70.3
84.4
98.4
182.8
225.0
253.1
281.3
309.4
337.5
365.6

68.1
85.1
102.1
119.1
221.2
272.3
306.3
340.3
374.3
408.4
442.4

100.0
125.0
150.0
175.0
325.0
400.0
450.0
500.0
550.0
600.0
650.0

Slab width
[mm]

Slab thickness
[mm]
200
250
300
350
650
800
900
1000
1100
1200
1300

Dimensions

Pumping station systems

Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity
Anchors
Design capacity

[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]

1500

1800

2100

2400

Rd12 x 70
20
Rd12 x 70
20
Rd16 x 80
43.2
Rd16 x 80
43.2
Rd20 x 127
80
Rd20 x 127
80
Rd20 x 127
80
Rd20 x 127
80
Rd20 x 127
80
Rd24 x 140
100
Rd24 x 140
100

Rd16 x 80
43.2
Rd16 x 80
43.2
Rd16 x 80
43.2
Rd16 x 80
43.2
Rd20 x 127
80
Rd24 x 140
100
Rd24 x 140
100
Rd30 x 170
138.4
Rd30 x 170
138.4
Rd30 x 170
138.4
Rd30 x 170
138.4

Rd16 x 80
43.2
Rd16 x 80
43.2
Rd16 x 80
43.2
Rd20 x 127
80
Rd24 x 140
100
Rd30 x 170
138.4
Rd30 x 170
138.4
Rd30 x 170
138.4

Rd16 x 80
43.2
Rd20 x 127
80
Rd20 x 127
80
Rd20 x 127
80
Rd20 x 127
80
Rd30 x 170
138.4

2700
Rd20 x
80
Rd20 x
80
Rd20 x
80
Rd20 x
80

3000

127 Rd20 x 127


80
127 Rd20 x 127
80
127 Rd24 x 140
100
127 Rd24 x 140
100

3300

4000

Rd20 x 127 Rd30 x 170


80
138.4
Rd24 x 140 Rd30 x 170
100
138.4
Rd30 x 170
138.4
Rd30 x 170
138.4

Only cast on site

37

Pumping station systems

Dimensions

Dimensions of concrete covers


Version 1, cover with concrete ring
D

220

D600/D800

FK [kN]

F
TM06 2046 3414

G
Lifting anchors
Pit 1200-3000

220
3

LA

220

FK [kN]

1
3

38

C40/50-2

35 mm
XC4
XF4
B500B
25

TM06 2045 3414

Concrete
Min. thickness of concrete on
top of the reinforcement
Concrete exposure class
Concrete exposure class
without pavement or covering
Reinforcement
Max. angle of inclination

Pumping station systems

Dimensions

Slab dimensions
Load FK
[kN]

Pit diameter
[mm]

A15 kN

1000
1200
1400
1600
1800
2000
2200
3000

2500
2500
2500
2500
3500
3500
3500
4500

x
x
x
x
x
x
x
x

2500
2500
2500
2500
3500
3500
3500
4500

B125 kN
x
x
x
x
x
x
x
x

100
100
100
100
100
100
100
150

2500
2500
2500
2500
3500
3500
3500
4500

x
x
x
x
x
x
x
x

2500
2500
2500
2500
3500
3500
3500
4500

x
x
x
x
x
x
x
x

C250 kN
150
150
150
150
150
150
150
150

2500
2500
2500
2500
3500
3500
3500
4500

x
x
x
x
x
x
x
x

2500
2500
2500
2500
3500
3500
3500
4500

x
x
x
x
x
x
x
x

D400 kN
200
200
200
200
200
200
200
200

2500
2500
2500
2500
3500
3500
3500
4500

x
x
x
x
x
x
x
x

2500
2500
2500
2500
3500
3500
3500
4500

x
x
x
x
x
x
x
x

200
200
200
200
200
200
200
200

Pumping stations, 1000, 1200, 1400 and 1600

Opening
diameter
600 mm
Opening
diameter
800 mm

Slab dimensions
[mm]

Reinforcement

Load
FK
[kN]

1. Main
bars

2. Opening
bars x 8

E
[mm]

3. Stirrups

F
[mm]

G
[mm]

4. Top
bars

5. Around
bars

Anchor
bolts

A15
B125
C250
D400
A15
B125
C250
D400

2500
2500
2500
2500
2500
2500
2500
2500

100
150
200
200
100
150
200
200

50
50
50
50
50
50
50
50

300
300
300
300
300
300
300
300

T10cc250
T10cc200
T12cc200
T12cc125
T10cc250
T10cc200
T12cc250
T12cc125

T12cc200L1400
T12cc200L1400
T12cc125L1400
T12cc200L1600
T12cc200L1600
T12cc125L1600

400
400
500
400
400
500

T10cc250
T10cc200
T10cc150
T10cc125
T10cc250
T10cc200
T10cc150
T10cc125

400
400
600
600
400
400
600
600

50
80
130
130
50
80
130
130

T8cc200
T8cc200
T8cc200
T8cc200

T10
2T10
2T12
3T12
T10
2T10
2T12
3T12

Rd16 x 80
Rd16 x 80
Rd20 x 127
Rd20 x 127
Rd16 x 80
Rd16 x 80
Rd20 x 127
Rd20 x 127

Anchor
bolts

Pumping stations, 1800, 2000 and 2200

Opening
diameter
600 mm
Opening
diameter
800 mm

Slab dimensions
[mm]

Reinforcement

Load
FK
[kN]

1. Main
bars

2. Opening
bars x 8

E
[mm]

3. Stirrups

F
[mm]

G
[mm]

4. Top
bars

5. Around
bars

A15
B125
C250
D400
A15
B125
C250
D400

3500
3500
3500
3500
3500
3500
3500
3500

100
150
200
200
100
150
200
200

50
50
50
50
50
50
50
50

300
300
300
300
300
300
300
300

T10cc250
T10cc175
T12cc200
T12cc125
T10cc250
T10cc150
T12cc175
T12cc100

T10cc250L1400
T12cc175L1600
T12cc100L1600
T16cc125L1800
T10cc250L1400
T10cc150L1400
T12cc175L1600
T12cc100L1600

500
525
500
500
500
600
525
600

T10cc250
T10cc175
T10cc200
T10cc125
T10cc250
T10cc150
T10cc175
T10cc100

400
400
600
600
400
400
600
600

50
80
130
130
50
80
130
130

T8cc200
T8cc200
T8cc200
T8cc200

T10
2T10
2T12
2T12
T10
2T10
2T10
2T12

Rd20
Rd20
Rd24
Rd24
Rd20
Rd20
Rd24
Rd24

x
x
x
x
x
x
x
x

127
127
140
140
127
127
140
140

Pumping stations, 3000

Opening
diameter
600 mm
Opening
diameter
800 mm

Slab dimensions
[mm]

Reinforcement

Load
FK
[kN]

1. Main
bars

2. Opening
bars x 8

E
[mm]

3. Stirrups

F
[mm]

G
[mm]

4. Top
bars

5. Around
bars

A15
B125
C250
D400
A15
B125
C250
D400

4500
4500
4500
4500
4500
4500
4500
4500

150
150
200
200
150
150
200
200

50
50
50
50
50
50
50
50

300
300
300
300
300
300
300
300

T10cc250
T10cc175
T10cc200
T12cc150
T10cc250
T10cc150
T12cc175
T12cc100

T16cc175L1800
T16cc100L1800
T16cc75L1800
T12cc150L1600
T16cc175L1800
T16cc100L1800

525
500
525
600
525
600

T10cc250
T10cc175
T10cc200
T10cc150
T10cc250
T10cc150
T10cc175
T10cc100

400
400
600
600
400
400
600
600

80
80
130
130
80
80
130
130

T8cc200
T8cc200
T8cc200
T8cc200

T10
2T10
2T10
2T12
T10
2T10
2T10
2T12

Anchor
bolts
Rd30
Rd30
Rd30
Rd30
Rd30
Rd30
Rd30
Rd30

x
x
x
x
x
x
x
x

170
170
170
170
170
170
170
170

39

Pumping station systems

A: Width of concrete slab


800...1500

Max. 25

100

5
1

250

150

150

300

550

T10

100

100

Max. 25

300

150

50

Dimensions

Version 2, cover with air space

2T1

TM06 3707 0915

Pit 1000-3000
Compacted coarse aggregate
gravel

800

A/5

Lifting anchors

A/5

Ha

tch

1
7

Concrete

40

Reinforcement
C40/50-2

Reinforcement

Lifting
T: B500B

Max. angle of inclination 25

35 mm
XF4*
0.45
0.4 %
6%

Without pavement or covering XF4.

TM06 3708 0915

Strength class
Min. thickness of the concrete on
top of the reinforcement
Exposure classes
Water-to-cement ratio
Max. chloride content
Max. water absorption by mass

Pumping station systems

Dimensions

Slab dimensions
Load FK
[kN]

Pit diameter
[mm]

A15 kN

1000
1200
1400
1600
1800
2000
2200
3000

2500
2500
2500
2500
3100
3100
3100
3900

x
x
x
x
x
x
x
x

2500
2500
2500
2500
3100
3100
3100
3900

B125 kN
x
x
x
x
x
x
x
x

400
400
400
400
400
400
400
400

2500
2500
2500
2500
3100
3100
3100
3900

x
x
x
x
x
x
x
x

2500
2500
2500
2500
3100
3100
3100
3900

x
x
x
x
x
x
x
x

C250 kN
400
400
400
400
400
400
400
400

2500
2500
2500
2500
3100
3100
3100
3900

x
x
x
x
x
x
x
x

2500
2500
2500
2500
3100
3100
3100
3900

x
x
x
x
x
x
x
x

D400 kN
500
500
500
500
400
400
400
500

2500
2500
2500
2500
3100
3100
3100
3900

x
x
x
x
x
x
x
x

2500
2500
2500
2500
3100
3100
3100
3900

x
x
x
x
x
x
x
x

500
500
500
500
400
400
400
500

Pumping stations, 1000, 1200, 1400 and 1600

Load FK
[kN]

A15
B125
C250
D400

Slab dimensions
[mm]

Reinforcement

1. Main
bars

2. Opening
bars

3. Stirrups
around

4. Opening
stirrups

5. Top bars

6.
Overhang
stirrups

7. Circular
stirrups

2500
2500
2500
2500

400
400
500
500

400
600
800
800

600
800
1000
1000

T10cc250
T10cc250
T12cc250
T12cc150

3T12cc200
4T12cc150
3T16cc200

T8cc250
T8cc250
T10cc250
T10cc150

T8cc250
T12cc250
T16cc225
T16cc125

T8cc200
T8cc200
T8cc200
T8cc200

T8cc250
T12cc225
T16cc200
T16cc125

T10cc250
T10cc250
T10cc200
T10cc150

Anchor
bolts x 4
Rd24
Rd24
Rd24
Rd24

x
x
x
x

140
140
140
140

Pumping stations, 1800, 2000 and 2200

Load FK
[kN]

A15
B125
C250
D400

Slab dimensions
[mm]

Reinforcement

1. Main
bars

2. Opening
bars

3. Stirrups
around

4. Opening
stirrups

5. Top bars

6.
Overhang
stirrups

7. Circular
stirrups

3100
3100
3100
3100

400
400
500
500

400
600
800
800

600
800
1000
1000

T10cc250
T10cc200
T12cc200
T12cc100

3T12cc200
4T12cc150
3T16cc200

T8cc250
T8cc200
T10cc200
T10cc100

T8cc250
T12cc250
T16cc225
T16cc125

T8cc200
T8cc200
T8cc200
T8cc200

T8cc250
T12cc225
T16cc200
T16cc125

T10cc250
T10cc250
T10cc200
T10cc150

Anchor
bolts x 4
Rd30
Rd30
Rd30
Rd30

x
x
x
x

170
170
170
170

Pumping stations, 3000

Load FK
[kN]

A15
B125
C250
D400

Slab dimensions
[mm]

Reinforcement

1. Main
bars

2. Opening
bars

3. Stirrups
around

4. Opening
stirrups

5. Top bars

6.
Overhang
stirrups

7. Circular
stirrups

3900
3900
3900
3900

400
400
500
500

400
600
800
800

600
800
1000
1000

T10cc250
T10cc150
T12cc150
T12cc100

3T12cc200
4T12cc150
3T16cc200

T8cc250
T8cc200
T10cc150
T10cc100

T8cc250
T12cc250
T16cc225
T16cc125

T8cc200
T8cc200
T8cc200
T8cc200

T8cc250
T12cc225
T16cc200
T16cc125

T10cc250
T10cc250
T10cc200
T10cc150

Anchor
bolts x 6
Rd24
Rd24
Rd24
Rd24

x
x
x
x

140
140
140
140

41

10

Pumping station systems

Grundfos Product Center

10. Grundfos Product Center


Online search and sizing tool to help you
make the right choice.
http://product-selection.grundfos.com

"SIZING" enables you to


size a pump based on
entered data and selection
choices.

"REPLACEMENT" enables you to find a replacement


product. Search results will include information on the
following:
the lowest purchase price
the lowest energy consumption
the lowest total life cycle cost.

"CATALOGUE" gives you


access to the Grundfos
product catalogue.

42

"LIQUIDS" enables you to find pumps


designed for aggressive, flammable
or other special liquids.

All the information you need in one place

Downloads

Performance curves, technical specifications, pictures, dimensional drawings, motor


curves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts.
The Product Center displays any recent and saved items - including complete projects right on the main page.

On the product pages, you can download


installation and operating instructions, data
booklets, service instructions, etc. in PDF format.

43

ECM: 1115766

GRUNDFOS A/S
DK-8850 Bjerringbro . Denmark
Telephone: +45 87 50 14 00
www.grundfos.com

The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

98697625 0615
Copyright Grundfos Holding A/S

Você também pode gostar