DRILLSHIP IADC SPECIFICATION

Page 2 of 28
11 June 2009
VERSION 04

DRAFT VERSION

OCEAN RIG STATEMENT:


THE DRILLSHIP IS A NEW BUILD UNDER CONSTRUCTION AND
THE BELOW INFORMATION IS BASED ON THE BUILDING
SPECIFICATION AND NOT AS BUILT DOCUMENTATION

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION

Page 3 of 28
11 June 2009
VERSION 04

1. Certificates
ITEM A. - UNIT Specifications
A.01. Unit Availability
A.02 Third Party systems and equipment actually on board
A.03. Unit general data
A.04. Main Dimensions
A.05. Operational Capabilities
A0.6. Storage Capacities
A.07. Unit Dynamic Positioning System
A.08. Environmental Operation limits
A.09.Operational Conditions and Limits
A.10.Survival Conditions and Limits

ITEM B. - General Rig Specifications


B.01. Derrick and Substructure
B.02. Drawworks And Associated Equipment
B.03. Derrick Hoisting Equipment
B.04. Rotation System
B.05. Derrick Winches

ITEM C - Power Supply Systems


C.01. Rig Power Plant
C.02. Air/Hydraulic Auxiliary Equipment

ITEM D - Blow Out Prevention Equipment And Accessories


D.01. BOP and Subsea Equipment
D.02. Marine Risers
D.03. BOP Control System
D.04. Subsea Control System
D.05. Choke/Kill System
D.06. Surface BOP Test facilities

ITEM E - Drill String and Handling Tools


E.01. Tubulars

ITEM F - Bulk Mud And Cement, Mud Treating And Circulating System
F.01. High Pressure Mud System
F.02. Low Pressure Mud System
F.03. Bulk Storage
F.04. Cementing Equipment

ITEM G ACCOMODATION
G.01. Offices
G.02. Living Quarters

ITEM H - Miscellaneous Equipment


H.01. Cranes &Handling Equipment
H.02. Helicopter Facilities

ITEM I - Environmental Equipment


I.01Environmental Equipment Provided and Systems in place

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 4 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION

VERSION 04

CONTRACTORS SHORT EQUIPMENT LISTING.

1 Certificates:
Nr.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

CERTIFICATES

Certificates of Class for Mobile Drilling Units, Hull and Machinery


Certificates of Fitness of Offshore Installation
Certificate of Registration as an Offshore Installation
Certificate of Examination and Record of Survey, Fire Fighting Regs 1978 (SUR 226 and 218)
Certificate of Examination and Record of Survey Life Saving Appliances Regs 1977
Annual Load Line Certificate.
Cargo Ship Safety RadioTelephone Certificate.
Cargo Ship Safety Construction Certificate.
Cargo Ship Safety Equipment Certificate.
Certificate of Registry
Certificate of Measurement
Record of Independent Inspection of Cargo Gear.
Record of Independent Inspection of Lifting Equipment.
Approved Operating Manual.
Proof of and Results of Inclining Experiment.
Certificates of Lifting Gear and Containers
Crane Slew Ring Safety Certificate.
Toolpusher's and Barge Master's Certificate.
Compliance with Department of Energy second edition guidance notes "Guidance on Design
and Construction, Structural Fire Protection for Accommodation and Control Spaces",
or equivalent.
20 Documentary evidence of compliance with a recognized standard for fired and unfired
pressure vessels, hydrostatic test on all pumps used solely for drilling purposes and electrical
equipment located in hazardous areas, as laid down in Department of Energy Construction
and Survey Regulations 1974, Schedule 2, Part VII, Equipment or equivalent.
21 Certificate of Insurance
22 Compliance with SI 1976 No. 1019. The offshore installation regulations (operational safety,
health and welfare), or equivalent.
Other documents required:
23 Compliance with MARPOL Annex 1 (International Oil Pollution Prevention Certificate);
Evidence of compliance with MARPOL Annex 2;
Evidence of compliance with MARPOL Annex 5;
Stability booklets.
24 Certificate of Registration of Offshore Installation.
25 International Load Lines Certificate.
26 Liberian Tonnage Certificate.
27 Safety Construction Certificate.
28 Safety Equipment certificate.
29 Safety RadioTelephone Certificate.
30 Ship Radio Station Certificate.
31 Mandatory Annual Survey reports as per IMO MODU CODE.
32 Certificate of Annual Inspection of Cargo Gear.

ISSUING
AUTHORITY

ISSUING
DATE

EXPIRING
DATE

ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS

TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA

New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build
New build

ABS

TBA

New build

ABS
ABS

TBA
TBA

New build
New build

ABS

TBA

New build

ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS
ABS

TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA
TBA

New build
New build
New build
New build
New build
New build
New build
New build
New build

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION

Page 5 of 28
11 June 2009
VERSION 04

ITEM A. - UNIT Specifications


ITEM

DESCRIPTION

CONTRACTOR'S DATA

A.01. Unit Availability


Actual status (Drilling/Iddle....)
New build, at Samsung Heavy Industries, Korea
Actual location (March 2009)
Availability
End of Actual Commitment (Date)
Estimated Moving Time to Angola
Estimated time of arrival in Angola
Mandatory Inspections:
1. Last 5-yars inspection/certification expires on (Date):
2. Next planned 5-years inspection/certification:
Planned Date:
Planned Location

ITEM

DESCRIPTION

CONTRACTOR'S DATA

A.02 Third Party systems and equipment actually on board


Schlumberger Electric Cementing Unit will be installed. Free
placement agreement
Third party utilities part of the installation
Third party utilities part of the installation
Third party utilities part of the installation
Third party utilities part of the installation
Third party utilities part of the installation
None
None
None

Cementing unit & ancillary equipment


ROV unit(s) & ancillary equipment
Electric wireline unit & ancillary equipment
Mudlogging unit & ancillary equipment
MWD/LWD unit & ancillary equipment
Drill stem test surface equipment
Marine supply vessels currently assigned to rig
Other 3rd party service equipment currently on rig
Other 3rd party services not mentioned above

ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

A.03. Unit general data


Owner
Unit Name
Unit Flag
Registered Number
Unit Classification
Unit Type
Rated drilling depth (with 5" DP)
Year of construction
Construction yard
Unit design
Positioning system (Anchored / DP)

Ocean Rig
To be advised, Unit #1 hull no 1837, unit #2 hull no 1838, unit #3 hull
no 1865, unit #4 hull no 1866
Malta (presently)
TBA
ABS, A1 Drilling Unit, AMS, ACCU, DPS-3, NBLES, SH-DLA, CDS
Drillship, dual derrick
ft
35,000
2010, 2011
Samsung Heavy Industries, Korea
Saipem 10000 design
Req. DP DP, DP Class 3

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

Page 6 of 28
11 June 2009
VERSION 04

CONTRACTOR'S DATA

A.04. Main Dimensions

ITEM

Main deck dimensionsh


No. and diameter of main columns
No. and diameter of small columns
Light Ship Weight
Gross tonnage
Drilling Draft / Displacement
Transit draft / Displacement
Survival draft / Displacement
Moon pool dimensions:
Max. opening through spider deck
heightPontoon

m
No./ ft
No./ ft
MT
MT
m / MT
m / MT
m / MT
mxm
m
m

DESCRIPTION

UNIT

Unit overall length, 228 meter


NA
NA
35,850
96,000
66,500
96,000
25,6 m x 12,48 m
NA

CONTRACTOR'S DATA

A.05. Operational Capabilities


A.05.1. Operational Capabilities
Transit speed towed/thrusters
Fuel consumption: transit/drilling
Designed Operating water depth: Min/Max
Maximum water depth as equipped
Accommodation for personnel

Knots
MT/day
m
m
No.

Self propelled 12 knots, design criteria


TBA
500 m to 3000 m
3000 m
217

A.05.2. Variable Loads


Total drilling variable load
Total survival variable load
Total transit variable load

MT
MT
MT

20,000
20,000
16,500

A.05.3. Helicopter facilities.


Size and capacity of helideck
Helideck Load Capacity (Gross and Specific):
Helicopter fuel storage capacity
Heli-refueling system type

m x m / MT 27,2 m x 27,2 m 21,3 MT (Chinook)


21,3 MT
gal
3 x 766 gal (3 x 2900 liter tanks)
In accordance with CAP 437

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

Page 7 of 28
11 June 2009
VERSION 04

CONTRACTOR'S DATA

A.06. Storage Capacities


Fuel
Drilling water
Potable water
Active liquid mud
Reserve liquid mud
Base oil storage
Brine storage
Waste liquid (mud and washing water)
Bulk bentonite/barite

Bulk cement
Sack storage
Pipe racks x area
Casing joints racking capacity

DP/DC racking capacity

Riser racks x area


Total riser joints racked with buoyancy
Total riser joints racked w/out buoyancy
BOP storage
X-Tree test area
Well Test Eq. area
Miscellaneous storage area

STon
m3
m3
m3
m3
m3
m3
m3
MT

MT
No / m2
MT / m2
No./ft

No./ft

MT / m2
No./ft
No./ft
MT / m2
MT / m2
m2
m2

7,500 MT
2,600
1,300
960
952
478
476
478
Bentonite/barite 4 x 113 m3 tot 452 m3
MT per tank:
Bentonite 108 (0,96 mt/m3)
Barite 244 (2,16 mt/m3)
4 x 113 m3 tot 452 m3
MT per tank:
Cement 158 (1,4 mt/m3)
1 large sack store, area TBA
Forward and aft pipe racks, Deck loading plan TBA
Variable Finger board racking capacity (stands of triple joints):
Condition 1:
13 3/8 casing, 80 stands
Condition 2:
9 5/8 casing, 105 stands
Condition 3:
7 casing 105 stands
Variable fingerboard DP racking capacity (stands of quadruple joints):
Condition 1:
6 5/8 DP 260 stands
5 7/8 DP 110 stands
4 DC 11 stands
6 DC 6 stands
8 DC 12 stands
9 DC 6 stands
Condition 2:
5 7/8 DP 370 stands
4 DC 11 stands
6 DC 6 stands
8 DC 12 stands
9 DC 6 stands
Condition 3:
6 5/8 DP 206 stands
3 DP 110 stands
4 DC 11 stands
6 DC 6 stands
8 DC 12 stands
9 DC 6 stands
Ref attached GA plan
110 / 9,990
12 / 1,080
Ref attached GA plan
Ref attached GA plan
Ref attached GA plan
Ref attached GA plan

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

Page 8 of 28
11 June 2009
VERSION 04

CONTRACTOR'S DATA

A.07 Unit Dynamic Positioning System


A.07.1.

Thrusters
Distance underside keel to underside thrusters
Thruster manufacturer
Number and location of thrusters
Thruster output (each) (MT)
Total installed power (kW)
Total available thrust (MT)

5,87 meter
Rolls Royce
6 ea. 3 sets bow and 3 sets stern
5,500 kW each thrust 900 kN each (100 MT)
6 each 7,000 kW total power 42,000 kW
600

A.07.2. Dynamic positioning Control system


DP System Classification
Manufacturer / Make / Type
Main DP Computer Control system (Number/Type)
Back-up DP Computer Control system (Number/Type)

DP Class 3
Kongsberg ICMS
2 each SDP
1 each SDP

A.07.3. Acoustic positioning system (including well spud-in reference point)


D.P. Acoustic Position reference
Number / Type

Kongsberg
2 each HIPAP 501

A.07.4. Vertical Reference Units


Number / Type

3 each MRU/Gyro

A.07.5. D.P.G.S. Position Reference System


Quantity / Type

2 each DPS 132, DPS 200

A.07.6. Wind & Current Speed & Direction Sensors.


Quantity and Type

3 each Gill wind sensors

A.07.7. Heading Sensors.


Quantity And Type

Ref A.7.4

A.07.8. Riser angle Indicators.


Quantity And Type

Riser angle displayed at DP consol, through NOV Shaffer


multiplex BOP control system. Not part of the DP
positioning system

A.07.9. Uninterrutable Power system.(UPS)


Unit Numbers and Types
UPS running time of each Unit at full load

ITEM

DESCRIPTION

3 each 230VAC 3kVA, 1-phase


As per ABS requirements

UNIT

CONTRACTOR'S DATA

A.08. Environmental Operation limits


Limits given for water depth
Maximum wind speed
Maximum wave height
Related wave period (to maximum wave height)
Maximum surface current speed
Air gap (below main deck)

m
knots
m
sec
knots
m

3000 meter
Wind velocity (10m, 10 minute) Vw=27 m/sec
Significant wave height Hs= 6.7 meter
Wave period (zero crossing) Tz= 7.0 10.0 sec
Current velocity (wind) Vc= 0.2 m/sec
Current velocity (tidal) Vc= 0.6 m/sec
NA

A.08.1 Environmental Survival Limits


Maximum wind speed
Maximum wave height
Related wave period (to maximum wave height)
Maximum surface current speed
Air gap (below main deck)

knots
m
sec
knots
m

100 knots
Significant wave height Hs=14.4 meter
Wave period Tp=17.0 sec
NA

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

Page 9 of 28
11 June 2009
VERSION 04

CONTRACTOR'S DATA

A.09. Operational Conditions and Limits


1.

Operational Condition
Contractor hereby states that the drilling unit meets the requirements under environmental conditions at least equal to the following
criteria which shall be considered as acting simultaneously and from any compass direction.
Wind speed (10 min.) : 50 knots
TBA, based on RAO curves when available
Maximum wave height : 10 meters
TBA, based on RAO curves when available
Significant wave period : 10 seconds
TBA, based on RAO curves when available
Surface Current Speed : 1 knots
TBA, based on RAO curves when available
Drilling: Shall include but not be limited to all normal drilling operations i.e. drilling, reaming, circulating, running casing, cementing,
round trips, etc.
Wind speed (10 min.) : 50 knots
Yes
Maximum wave height : 10 meters
Yes
Significant wave period : 10 seconds
Yes
Surface Current Speed : 1 knots
Yes
2.
Operational Limits
Limits given for water depth (Minimum / Maximum)
meters Ref item A7 & A8
Maximum Wind Speed
knots
Maximum wave height
meters
Related wave period
sec.
Surface current speed
knots
Air gap
meters

ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

A.10. Survival Conditions and Limits.


1.

2.

Survival Conditions.
The conditions under which the drilling rig is capable of remaining safely on location, although not necessary operational, are the following
criteria which shall be considered as acting simultaneously and from any compass direction:
Maximum 1 minute wind speed
km/hr
Maximum 10 minute wind speed
km/hr 31 m/sec (112 km/kr)
Maximum 2 hour wind speed
km/hr
Maximum 24 hour wind speed
km/hr
Maximum wave eight
feet
Significant height Hs=8.5 meter (28 ft)
Associated wave period
second Wave period (zero crossing) Tz=8.0 11.0 sec
Maximum surface current velocity
Knots Current velocity (wind) Vc=0.25 m/sec
Current velocity (tidal) Vc=0.6 m/sec
Survival Limits.
Maximum wind speed
km/hr 185.2 km/hr (100 knots)
Maximum wave eight
feet
Significant wave height Hs=14.4 meter (47.25 ft)
Maximum wave period
sec.
Wave period Tp=17.0 sec
Maximum surface current velocity
Knots
Air gap (below main deck)
meters NA

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION

Page 10 of 28
11 June 2009
VERSION 04

ITEM B - General Rig Specifications


ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

B.01. Derrick and Substructure


Derrick/mast
Make type. Build as per rules
Rated for wind speed with empty setback load
Rated for wind speed with full setback load
Gross nominal capacity
Number of lines
Static Hook Load Capacity with max. number of lines
Copy of Mast certification to be submitted:
Derrick mast to be fitted with heavy duty, tight, fluorescent lighting system,
certified for use in division 1 or division 2 areas as required by IP, API or
other national codes.

ITEM

DESCRIPTION

knots
knots
MT
No
MT
Yes/No

Dual derrick, ABS CDS Class


TBA
TBA, under engineering (100 survival, 70
operating)
907
14
907 / 14
Yes

UNIT

CONTRACTOR'S DATA

B.02. Drawworks And Associated Equipment


B.02.1. Drawworks
Make and Type
Input power continuous / Input power maximum
Main Drum type and dimensions (OD x Length)
Main Drum rated maximum line pull with:
- 12 lines / 10 lines / 8 lines
Maximum pull on travelling block with maximum nr. of lines / number of lines
Low Speed Main Drum clutch make and type and Rated Pull

kW
MT
MT / No

2 each NOV, SSGD-1000


AC driven 4290 / 6006
55 (1397mm) x 82 (2083mm)
907 / 14
Direct drive, gear ratio 1:10,5

B.02.2 Drawworks Brake


B.02.1.1 Brake Mechanism
Make / Model
Independent backup system
B.02.1.2 Auxiliary Brake
Make / Model
Independent back-up system

Yes/No

Regenerated braking system with disc brake


Yes dual brake system
NA

Yes/No

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 11 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

VERSION 04

CONTRACTOR'S DATA

B.03 Derrick Hoisting Equipment


B.03.1 Crown Block
Make/Type. Builded as per rules:
Rated capacity
No. of sheaves

MT
No

2 each NOV, ABS CDS


907
6 plus deadline and fast line sheave

MT

2 each NOV, ABD CDS


907

B.03.2 Travelling Block


Make/Type. Builded as per rules:
Rated capacity
B.03.3 Hook
Make/Type. Builded as per rules:
Rated capacity

NA
MT

B.03.4 Swivel Head


Make/Type. Builded as per rules:
Rated capacity and Working pressure
Completed with access fitting for wireline entry on top of gooseneck

MT / PSI
Yes/No

Integrated in the top drive


7500 psi
Yes

Inch / m
Yes/No
Yes/No
Yes/No
Yes/No

ABS CDS
2 each 2 x 2286 meter (7500 ft)
Yes
Yes
Yes
Yes 1 each 2286 meter

Yes/No

2 each NOV, ABS CDS


200,000 lbs
Yes compression type load cell

Yes/No

NOV integrated to the top drive


Yes

B.03.5 Drilling Line


Builded as per rules:
Type / Size (min.) / Length (approx. left on drum)
Completed with support frame for drum/cover
Drilling line drum power driven
Anchor Deadline Block Guidance System.
Spare reel of drilling line (approx. length available on spare reel)

B.03.6 Anchor Dead Line


Make/Type. Builded as per rules:
Rated capacity
Completed with weight sensor. If Yes specify type.

B.03.7 Block Guidance System


Make/Type
Completed with dolly/rails

B.03.8 Retraction System For Traveling Block (If fitted)

Yes/No

Make/Type

B.03.9 Top Drive Guidance System

2 each NOV hydraulic retract. Integrated to


the top drive

Yes/No

Make/Type

2 each NOV, hydraulic retract system

B.03.10 Heave Compensator


Crown or Travelling Block Mounted
Make/Type
Stroke
Rated Capacity compensated / locked

ft
MT

Crown mounted
2 of each NOV,
CMC (Crown Mounted Compensator)
AHC (Active Heave Compensator)
25
454 / 907

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 12 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

VERSION 04

CONTRACTOR'S DATA

B.04 Rotation System


B.04.1 Rotary Table
Make/Type

Main well center:


NOV RST 605 hydraulic driven
Aux well center:
NOV RST 605 false rotary table

Maximum opening

Inch

Main well center: 60


Main well center: 60

Rated static capacity

MT

Main well center: 910


Main well center: 910

Rated rotation capacity (@100 RPM)

MT

Main well center: NA, max RPM 15


Main well center: NA

Two speed gearbox.

Yes/No

Main well center: No hydraulic driven


Main well center: NA

Emergency chain drive electric motor.


Soft Torque Rotary System

Yes/No
Yes/No

NA
NA

MT
PSI
RPM
Yes/No

2 each NOV, HPS-03-1000, ABS CDS


907
7500
280
Electric AC driven

B.04.4 Top Drive


Make / Type. Builded as per rules:
Static rated load capacity
Test / working pressure
Maximum speed
Driven by electric/hydraulic motor
B.04.4.1 Top Drive Inside BOP:
a.
Remote operated Inside BOP make and type
For DP sizes
Maximum working pressure
b.
Manual operated Inside BOP make and type
For DP sizes
Maximum working pressure
B.04.4.2 Top Drive Pipe Handler System
Unit fitted with pipe handler for make up and break out
Make / type
Maximum Break-Out Torque

Yes/No
Inch
PSI
Yes/No
Inch
PSI
Yes/No
ft.lbs

Yes
Mounted onto drive shaft and lower IBOP
15,000
Yes
Mounted onto upper IBOP and saver sub with
5 7/8 TT5/8 connection. Can be made for
any connection up to 8
15,000
Yes
NOV
115,100 (156,000 Nm)

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 13 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

VERSION 04

CONTRACTOR'S DATA

B.05 Derrick Winches


B.05.1 Rig Floor Winches
Quantity
Make / Type (Air or Hydraulic)
Rated Capacity

MT

4
NOV, hydraulic winches
5

MT
Yes/No

3
NOV, hydraulic winches
0.150 (150 kg)
Yes

B.05.2 Rig Floor 'Man-Riding' Winch


Quantity
Make / Type (Air or Hydraulic)
Rated Capacity
Certified man-riding

B.05.3 Derrickman Platform Work-Winch


Quantity
Make / Type (Air or Hydraulic)
Rated Capacity

NA
MT

B.05.4 Utility Winch


B.05.4.1 Main Deck Winch
.
Quantity
Make / Type (Air or Hydraulic)
Rated Capacity
Certified man-riding
B.05.4.2 Cellar Deck Hoisting Winch
.
Quantity
Make / Type (Air or Hydraulic)
Rated Capacity
Certified man-riding

NA
MT
Yes/No

MT
Yes/No

4
NOV, hydraulic winches
5
Utility winches not certified for man riding
3 each dedicated man riding winches located
on cellar deck
Cap 150 kg, certified for man riding

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 14 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION

VERSION 04

ITEM C - Power Supply Systems


ITEM

C.01

DESCRIPTION

12,960 (12.6 Mw)

No.
Yes/No

3 each engine rooms


No

No.
kW

6 each STX-B&W 16V32


6 x 8000 kW total 48,000 kW

Diesel Engines
Make, Type, Quantity
Maximum continuous power

C.01.3

kW

Engine Room
Engine room walls type
Engine room positive pressurized

C.01.2.

Generator
Make / Type and Quantity
In the drilling mode sufficient power must be available to control and Yes/No
power simultaneously three mud pumps and TDS / Rotary Table both
at full load and the drawworks at half load with one diesel engine
generator as a stand-by.
AC or DC
Maximum continuous power of each
kW

C.01.4

ITEM
C.02.1

AC
6 x 7,000 kW, total 42,000 kW

DESCRIPTION

No
kW
Amps
No./kW

ABB, AC variable frequency drives (VFD)


12,960
16 / 12,960

UNIT

CONTRACTOR'S DATA

Air/Hydraulic Auxiliary Equipment


Hydraulic Power Pack(s)
Make / Type and Quantity
Maximum continuous power

C.02.2

6 each ABB AMG 900 LSE


Yes

SCR System
Make / Type and Quantity of SCR's
Maximum continuous power
SCR Output Amperage / Voltage
No. of motors that SCR can run simultaneously

C.02

CONTRACTOR'S DATA

Rig Power Plant


Maximum power available for drilling operations

C.01.1.

UNIT

HP

NOV Ringline HPU unit


1,126

Hydraulic Operated Functions on Rig


Functions (Tenderer to specify)

C.02.3

All Pipe handling systems, including catwalk


machines
BOP handling systems
Utility winches
Man riding winches
Rotary table
Active heave compensator

Rig Service Air System


Air compressors:
Make / Model and Quantity
Rated flow capacity
Air vessel total capacity
Working pressure
Air dryers:
Make / Type and Quantity
Capacity

No
scfm
scfm
psi

EMD, 4 each
1200 m3/hr
2 each 5,5m3
131 (9 bar)

No
cf

2 each desiccant type


2,400 Nm3/hr

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 15 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION

VERSION 04

ITEM D - Blow Out Prevention Equipment And Accessories


ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

D.01 BOP and Subsea Equipment


General Data
BOP stack size
Builded as per:
Last BOP periodical inspection
Last BOP Overhaul Inspection
D.01.1 Flex Joint
Quantity / Make / Type
Size
Maximum deflection

Inch x psi

18 15,000 psi
NOV Shaffer Extended Triple NXT 6 rams 2 ea
annulars
New build

No.
Inch
Deg

1 each Oilstate
18
10

Inch
Psi

NOV Shaffer 500 psi


21
500

D.01.2 Diverter BOP (for installation in fixed bell nipple)


Make / Model
Size
Working Pressure
D.01.3 Diverter Flow Lines
Quantity
OD of flow lines running from diverter to valves
OD of flow lines running from valves to end of lines
Diverter lines running to (starboard/side)
Control valves Type and Make
Remote controlled from

No
Inch

3
18
18 nominal
Yes
Actuated ball valves
Drillers house, central control room

D.01.4 BOP Stack


a)
b)

c)
d)
e)
f)

g)
h)
i)

18" BOP stack, 15,000 PSI suitable for H2S service comprising:
One adapter to fit the hydraulic connector.
Yes/No
Four ram type preventers with ram locks.
Yes/No
The Top and Bottom Rams shall be suitable to fit pipe rams (standard Yes/No
or variable) and the two middle rams shall be capable to shearing rigs
drill pipe.
Each ram type preventer to be provided with two side outlets.
Yes/No
In total four are to be blanked off.
Spacing between two ram preventers shall be 27 inch
Yes/No
One hydraulic wellhead connector to fit the wellhead provided with hot Yes/No
tap for underwater intervention.
- Two 3" dedicated choke and two 3" dedicated kill line outlets Yes/No
with each two hydraulic fail-safe valves, solid block;
Necessary subsea accumulators.
Yes/No
BOP control system (with dedicated UPS, if applicable) state reaction Yes/No
time in seconds (time between operating control unit and BOP closed).
Annular
Sec
Ram
Sec
Stack complete with guide frame, pick-up attachment and transport Yes/No
base.
One test stump for testing BOP stack
Yes/No
Up-dated drawing of BOP stack and control system to be submitted as Yes/No
required.

Yes
Yes 6 rams
Yes
Yes
yes
Yes, Vetco Super HD H4 DWD type 15,000 psi for
30 Well Head
3 1/6 outlets
Yes
Yes NOV Shaffer multiplex control system
TBA
TBA
Yes
Yes
Yes

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 16 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


ITEM
a)

b)
c)

DESCRIPTION

UNIT

Notes For Used Equipment:


Marine risers to be inspected by Tuboscope, Vetco or equivalent. All pipe welds
(circumferential or longitudinal) and coupling welds are to be ultrasonically or
magnetic particle inspected. Spot checks are to be made on used risers to determine
wall thickness and to verify whether here has been any excessive internal wear. All
couplings are to be cleaned and inspected.
The frequency of inspection must be as per API regulation.
Choke and kill lines to be pressure tested to working pressure connections to be MPI
inspected and wall thickness spot checks of body are required (Yes/No).
The frequency of inspection must be as per API regulation.
Used blow-out preventers to be completely dismantled, inspected by a Company
approved established inspection party and re-assembled. They are to be shop tested
by blanking off the top and bottom and the body tested to the original body test
pressure (normally 1.5 time the WP). Rams and bag type preventer to be tested to
their working pressure.
The frequency of inspection must be as per API regulation.

ITEM
DESCRIPTION
D.01.5 BOP Stack (From Bottom To Top)

UNIT

D.01.5.1 Wellhead Connector


Make / Type

VERSION 04

CONTRACTOR'S DATA
Contractor statement:
All new risers, new build

Contractor statement:
All new choke and kill lines, new build
Contractor statement:
Yes, new build

CONTRACTOR'S DATA

Size and Working Pressure


Spare connector same type
Hot tap for underwater intervention
D.01.5.2 Ram Type Preventer (with two 3" side outlets)
Single or double. Quantity, Make / Type

Inch / PSI
Yes/No
Yes/No

Vetco, Super HD H4 DWD type, 15.000 psi for 30


wellhead
18 15,000 psi
Yes
Yes

Size and working Pressure


D.01.5.3 Bag Type Preventer
Make / Type
Size and working Pressure
D.01.5.4 Mandrel
Make / Type
Size /and Pressure Rating

PSI

Tripple, 6 ram, NOV Shaffer Extended Triple NXT


BOP, 3 1/16 side outlets
18 15,000 psi

PSI

NOV Shaffer,
10,000 psi

PSI

NOV Shaffer
10,000 psi

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 17 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


ITEM
DESCRIPTION
D.01.6 Lower Marine Riser Package (from Bottom to Top)
D.01.6.1 Hydraulic Connector
Make / Type
Size Working Pressure
Hot tap for underwater intervention
D.01.6.2 Bag Type Preventer
Quantity, Make / Type
Size and Working Pressure
D.01.6.3 Flex Joint
Make / Type
Size and Maximum Deflection Angle
D.01.6.4 Riser Adapter
Size / Make / Type

UNIT

VERSION 04

CONTRACTOR'S DATA

Inch / PSI
Yes/No

Vetco, EXF HAR H4 18


18 10,000 psi
Yes

Inch / PSI

2 each, NOV Shaffer, Spherical Blowout Preventer


18 10,000 psi

Oilstate, 18
Inch / Deg. 18 , 10 deg
Inch

18 NOV Shaffer

No.
Inch / No.
No.
No.
No.

2
2
Variable ram
Variable ram
4

D.01.7 Pipe Rams Available (incl. Spares as required)


Shearing blind rams sets quantity
Size and DP rams sets quantity (Size suitable for rig DP's)
3" rams sets quantity
4" rams sets quantity
Variable rams sizes and sets quantity

D.10.8 BOP Stack Handling System


Description:
General remarks:
1.
All necessary clamps, bolts, nuts and gaskets for above BOPs
Yes/No
2.
Submit drawing giving detailed data on pressure ratings and Yes/No
dimensions of BOP stacks and its components

Yes
Yes, new build note preliminary drawings

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 18 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

VERSION 04

CONTRACTOR'S DATA

D.02 Marine Risers


D.02.1 Marine Risers Joints
Make / Model. OD x ID
Type of riser connectors
Average Length of a single joint
Weight of one complete joint
Quantity
Date/Type of last inspection

Meters
lbs
No

NOV Shaffer, H FT H
Flanged
27.43 m (90 ft)
35,858 (7/8 wall) - 36,973 (15/16 wall) without
buoyancy elements
112 (10,000 ft water depth)
All new riser

D.02.2 Marine Risers Pup Joints


Quantity and Length

No / meters

D.02.3 Telescopic Joint.

One 13.7m stroke telescoping joint (double seals are required) complete with rotating support ring for tensioning lines 10,000 or 15,000
psi - 3" bore kill and choke, booster line/hoses. Spare telescopic joint is required.
Make / Type
NOV Shaffer, FT
Size
inch
Outer ballel 24 OD, Inner barrel 21 OD
Maximum stroke
meters
19,81 (65ft)
Spare telescopic joint
Yes/No
Yes

D.02.4 Instrumented Joint.


Make / Type
Data recorded

NA

D.02.5 Kill/Choke/Glycol Injection Lines (one of each):


Outside / Inside diameter
Working Pressure
Dedicated glycol injection line available
Gylcol to be pumped through kill/choke lines

Inch
PSI
Yes/No
Yes/No

6 4
15,000
No
Yes

Inch
PSI
Yes/No

5 4
7,500
Yes

Inch

2 each Conduit lines


2.875 OD 0.276 wall 5000 psi

D.02.6 Booster Line (required)


Outside / Inside diameter
Working Pressure
Hydraulic Shut off valve (required)

D.02.7 Riser Control BOP lines


Quantity
Outside / Inside diameter

D.02.8 Last Riser Inspection Report


Date and type of last inspection performed

D.2.9

All new risers

Ball (Flex) Joint


Make / Type
Size
Maximum deflection
Spare ball (flex) joint

inch
Deg.
Yes/No

Oilstate flexjoint
18
10
Yes

D.02.10 Buoyancy Modules (Required)


Make and Quantity
Water depth rating
Buoyancy in sea water

meters
lbs

Riser equipped with buoyancy elements for


operation up to 3000 m water depth
3000

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 19 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

VERSION 04

CONTRACTOR'S DATA

D.03 BOP Control System


D.03.1 General Data
BOP Control System (Hydraulic-Electric/Hydraulic)
Pressure assisted (if hydraulic)

Multiplex
Yes/No

D.03.2 Surface Accumulator Unit


Make / Model / Type
Installation site
Soluble oil reservoir capacity
Oil/water mixing capacity
Glycol reservoir capacity
No. of bottles installed / Capacity each bottle. Total bottles capacity
Bottle working pressure
D.03.2.1 Accumulator Bottles on BOP Stack
No. of bottles installed on BOP/LNRP
Capacity of each and total bottles capacity
Bottles working pressure

NOV Shaffer
litres
lt/min
litres
No / gal
psi

3,785
378
1.893
81 / 15 / 1,215
5000

No.
litres
psi

142
56.78
5000

D.03.3 Triplex Pumps


Make / Type / Model and Quantity
Each driven by motor of
Flow rate of each pump at maximum operating pressure

ITEM

DESCRIPTION

No.
NOV Shaffer, triplex, 2 each
kW
112
Gpm / psi 43.5 / 5000

UNIT

CONTRACTOR'S DATA

D.04 Subsea Control System


Two reels with hydraulic control hoses with a length suitable for the Yes/No
specified water depth for the control of the BOP functions. A third hose
reel should be available as a back-up, or alternatively enough length to
be available on the two main reels to serve as back-up.

2 each multiplex cables and 1 each hydraulic hotline

D.04.1 Control Pods Assembly


Make / Type / Quantity (min. one spare assembly required)
Control valves quantity

No.
No.

NOV Shaffer, 2 each


122 per control pod

No.
meters

NOV Shaffer, 1 each hotline reel


3,000

No.
meters
No.

2 each multiplex control cables


3000 m each
NA

D.04.2 Hose Reels


Make / Type / Quantity
Maximum length

D.04.3 Pod Hose


Quantity
Total / Useful length
Pilot hoses quantity

D.04.4 Pod Hose Manifold


Make / Model

ITEM

NA

DESCRIPTION

UNIT

CONTRACTOR'S DATA

D.05 Choke/Kill System


D.05.1 Choke Manifold
Make
Size and Working Pressure

D.05.2 BOP Choke/Kill Lines From Riser To Choke Manifold


Make / Type
Inside Diameter and Working Pressure

NOV Shaffer
Inch / psi 3 1/16 valves , 15,000 psi
Flexible section
Rigid Section
Coflexip
Inch / psi 15,000
5 nominal, 15,000 psi

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 20 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


ITEM

DESCRIPTION

UNIT

VERSION 04

CONTRACTOR'S DATA

D.06 Surface BOP Test facilities.


D.06.1 Hydraulic BOP Test Stump
Make / Model
Pressure rating

psi

Vetco, H4
15,000

Yes/No

TBA

D.06.2 POD Test Stump


Availability
Model / Make

ITEM E - Drill String and Handling Tools


ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

E.01 Tubulars
E.01.1 Drill Pipe
OD / ID

Grade
Range
Weight
Connection

Actual API classifications


Date of last inspection
Total Joints Available

lb/ft

inch

E.01.2 Hevi-wate Drill Pipe


OD/ID
Grade
Range
Weight
Connection

Actual API classifications


Date of last inspection
Total Joints Available

b.

c.

d.

b.

c.

d.

b.

c.

d.

lb/ft

inch
meters

E.01.3 Drill Collars


Quantity of joints
API steel grade
OD / ID Body
Length of each joint
Connection
Actual API classifications
Date of last inspection
Drill Collars (Continue)
Quantity of joints
API steel grade
OD / ID Body
Length of each joint
Connection
Actual API classifications
Date of last inspection

a.
5 7/8OD
(pipe body)4 (tool
joint ID)
S-135
2
23.4
7 TT585
(GrantPridec
o Turbo
Torque)
NS1
New
7,500 meter
a.
5 7/8 / 4
HW-120
2

No.
Inch
meters

7 TT585
(GrantPridec
o Turbo
Torque)
NS1
New
40
a.
9
30
9 / 3
9.45
7 5/8 REG
NS1
New
e.

30

8 / 2,812 6 / 2.812
9.45
9.45
6 5/8 REG NC 50
NS1
NS1
New
New
f.
g.

No.
Inch
meters

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

h.

Page 21 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION

VERSION 04

ITEM F - Bulk Mud And Cement, Mud Treating And Circulating System
ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

F.01 High Pressure Mud System.


.

F.01.1 Mud Pumps

Three triplex pumps, each equipped with an independent driven centrifugal charging pump. Minimum pump power rating 1150-1275kW.
Minimum output of 2.3m3/min. each at 90% of maximum SPM. Working pressure 5,000psi. It shall be possible to line up 2 mud pumps
on the well and 1 on the riser booster line simultaneously.
a) Forged steel fluid ends
Yes/No
Yes
b) Quick change system for liners and pistons
Yes/No
No
c) Quick change valve covers
Yes/No
No
d) Cooling/lube oil system for liners
Yes/No
Yes
e) High pressure pulsation dampeners (if YES - Make/Type)
Yes/No
Yes
f) Reset relief valve (if YES - Make/Type)
Yes/No
Yes
g) Suction and discharge filter
Yes/No
Yes
h) Full range of liners and pistons to operate at the optimum
Yes/No
Yes, two different sizes
volume/pressure as required by the drilling programme
i) Each pump equipped with a pressure gauge before isolation valve. Yes/No
F.01.1.1. Mud Pumps No:
No. 1
No. 2
No. 3
No. 4 & No. 5
Make / Model
NOV/
NOV/ 14P- NOV/ 14P- NOV/14P
14P-220 220
220
Rated Input Power
kW
1640
1640
1640
1640
Mud pump motors: Quantity
No
2
2
2
2
/
Make / Model
Baylor / Baylor
/ Baylor
/ Baylor
CM628TU CM628TUT CM628TUT CM628TUT
T
Continuous rating power of each
kW
918
918
918
918
Liner sizes available
Inch
6
6
6
6
Surcharging pump type
Centrifuga Centrifugal Centrifugal Centrifugal
l
Fluid end type
Suction line diameter (OD x ID)
Inch
10
10
10
10
Mud Pumps - Rig floor mud manifold line diameter (OD x ID)
Inch
5 nom
5 nom
5 nom
5 nom
Working pressure
Psi
7,500
7,500
7,500
7,500

F.01.2 Standpipe Manifold


Two standpipes with goosenecks connected to a H-type standpipe manifold c/w:
Standpipe Line (number)
No.
Dimensions OD x ID
Inch
Working pressure
Psi
Test pressure
Psi
Kill line outlet
Yes/No
Fill-up/bleed-off line outlet (i.e. manual choke)
Yes/No
Two 2" outlets c/w hammer Lug wing unions (Fig. 1502) type Yes/No
connections

4
5 nom
7,500
10,000
Yes
Yes
Yes

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION

Page 22 of 28
11 June 2009
VERSION 04

F.02 Low Pressure Mud System


ITEM
DESCRIPTION
F.02.1 Mud Pits (Active, Reserve and Mixing) System.

a)
b)
c)
F.02.1.1

F.02.1.2

F.02.1.3

F.02.1.4

F.02.1.5

F.02.1.6

UNIT

CONTRACTOR'S DATA

At least four main mud tanks with a total capacity of 250m3 and reserve capacity to store the marine riser content in case of an
emergency. Each tank equipped with a mud mixer giving a turn- over time of 45 - 75 sec. The mud active tank to be dimensioned such
that a volume change of 1m3 is indicated by a level change of at least 10cm. Mud tanks to be sectionalized for a series treatment by solids
removal equipment (e.g. shaker, D-gas, D-sand, D-silt, suction tanks).
Mud system to be capable of mixing/treating/maintaining muds up to 2 Yes/No
Yes
kg/lt. at circulation rates up to 5bbl/min.
All mud tanks to be covered and a forced ventilation system installed.
Tanks covered
Yes/No
Yes
Forced ventilation system
Yes/No
Yes
Storage space to be available for contaminated/waste mud for Yes/No
Yes
transport to shore.
Active Mud Tanks
Tank Number
10 each
2 each
Capacity (Single active tank)
cubic m. 80
40
Total capacity
cubic m. 880
Tank
Degasser Desander
Desilter Mud Clean.
Capacity
cubic m. 20
20
20
20
Reserve Mud Tanks
Tank Number
4
Reserve
1
Waste mud
Capacity (Single reserve tank)
cubic m. 238
Reserve
478
Waste mud
Total capacity
cubic m. 952
Reserve
478
Waste mud
Tank
Degasser Column port Column stbd
Other
Capacity
cubic m.
Drill Water Tanks
No. 1
No. 2
No. 3
No. 4
Capacity (single drill water tank)
Total capacity
2.600
Potable Water Tanks
No. 1
No. 2
No. 3
No. 4
Capacity (single tank)
cubic m.
Total capacity
cubic m. 1,300
DMA (Low Toxicity Base Oil) Tanks
No. 1
No. 2
No. 3
No. 4
Capacity (single tank)
cubic m.
Total capacity
cubic m. 450
Brine Tanks
No. 1
No. 2
No. 3
No. 4
Capacity (single tank)
cubic m.
Total capacity
cubic m. 450

F.02.1.7 Settling Tank (One setting tank of about 15m3 capacity with sloping bottom and two quick acting dump valves with m2 openings)
No. 1
No. 2
No. 3
No. 4
Capacity (single tank)
cubic m.
Total capacity
cubic m. 98 drain
holding tank
F.02.1.8 Pill/Slug Tank
Drillwater, sea water and DMA (base oil) supply lines complete with one paddle mixer. C/w mud mixer as detailed in F.2.1
Capacity
cubic m. 20
F.02.1.9 Trip Tank
Complete with centrifugal pump and mud level indicator readable from the Driller's position and console, with the ability to isolate trip tank
system from mud return system. Able to handle mud gradient up to 2 kg/lt.
Location
Capacity
cubic m. 1,2 stripping tank
10 trip tank
Linear Capacity
m3 / m
TBA
Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 23 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


Level indicator Type (Mechanical.)
Level indicator Location (Driller's side)
Alarm and strip chart recorder
Electric pump make / model

ITEM
DESCRIPTION
F.02.3. Mud Return Treatment System

Yes/No

UNIT

VERSION 04

Electronic
Yes
Yes
2 ea 100m3/hr

CONTRACTORS DATA

F.02.3.1 Flow Line


Shape and Size
Inch
5 deg slope, 18 nominal
F.02.3.2 Sand Trap
Quantity and total Capacity
No. / bbls NA
F.02.3.3 Shale Shaker
Independently driven linear motion shale shakers capable of handling 4.5m3/min. of 50/60 secs. March Funnel viscosity mud through
API mesh 60 screens. A full range (20 mesh - 300 mesh inclusive) of screens must be available by the Contractor at all times.
Contractor to maintain at least Company approved minimum consumables (screens, etc.) stocking levels.
a.
Primary Shale Shakers
No. 1
No. 2
No. 3 & 4
No. 5 & 6
Make / Type
Brandt VSM Brandt VSM Brandt VSM Brandt VSM
300
300
300
300
Maximum flowrate per shaker, (screen size dependent)
lt/min
2000
2000
2000
2000
Size and type of screens
As per contract
b.
Secondary Shale Shakers
No. 1
No. 2
No. 3
No. 4
Connected mode to primary shale shakers (cascade. Etc.)
Make / Type
Maximum flowrate per shaker
lt/min
Size and type of screens
F.02.3.4 Desander
A full range of screens must be available by the Contractor at all times. Contractor to maintain at least Company approved minimum
stocking levels.
Make and Type and Quantity
1 ea 3 cone 12
Max. flowrate
lt/min
F.02.3.5 Desilter
Make and Type Quantity
1 ea 24 cones 4
Max. flowrate
lt/min
F.02.3.6 Mud Cleaner
Full range of screens 50 mesh - 300 mesh to be available from Contractor.
Contractor to maintain at least Company approved minimum stocking levels.
Make and Type and Quantity
NA
Max. flowrate
lt/min
F.02.3.7 Mud/Gas Separator (Poor Boy)
Make and type
RB Pipetech, poor boy
Outside Diameter size
Inch
78
Height
feet
14
Mud inlet connection (from choke) size and working pressure
Inch/psi 5 / 10,000
Mud outlet connection (from choke) size and working pressure
Inch/psi
Mud liquid seal height
ft
24
Gas discharge line OD
Inch
12
Gas discharge line running to
Above derrick top
Equipped with pressure sensor
Yes/No
Yes
Equipped with temperature sensor
Yes/No
Yes
F.02.3.8 Degasser
Make / Type and Quantity
2 each NOV Brandt / DG Series
Discharge line running to
Degasser tank
Discharge line O.D.
Inch
8
Location of degasser suction tank
Mud pit room
F.02.3.9 Mudsaver Sub
Two (2), to be used with all pipe pulling/running/drilling, etc.
Yes/No
As per contract
F.02.3.1 Mud Saver Bucket
0
Quantity
1
Pipe size
Inch
5 7/8
Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 24 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION


Complete with 4" return hose to flowline/flow nipple

Yes/No

ITEM
DESCRIPTION
F.02.4. Mud Mixing System

UNIT

ITEM

UNIT

VERSION 04

Yes

CONTRACTOR'S DATA

Mud Mixing system shall allow simultaneously mixing of new mud and weighting active or reserve mud.
F.02.4.1 Mud Hopper
System to be able to treat mud in the active system or mixing a pill or reserve mud whilst not interfering with the mud pump and charging
pump operation 6" piping with a minimum velocity in the lines of 10 ft/sec.
Output of pumps (Requested 27 - 40bbl/min at 27 psi.)
NOV automatic mud mixing system with sack cutting
system
Make / Model and Quantity
No.
NOV
F.02.4.2 Mixing Pumps
Make / Model / Type and Quantity
No
3 each 8x6x14 227 m3/hr
F.02.4.3 Chemical Mixing Tank
Number
No
2
Capacity
20 m3 each
Completed with electrical mixer
Yes/No
Yes

DESCRIPTION

CONTRACTOR'S DATA

F.03 Bulk Storage


F.03.1 Barytes/Bentonite Silos
Capacity
Total capacity
Type Weight loadcell
Last internal inspection (Type and Date)
Relief valve(s) installed

m3
m3
Yes/No

F.03.2 Cement Silos, at Deck Level/Below Deck


Capacity at deck level/main storage of each
m3
Total Capacity at deck level/main storage
m3
Type Weight loadcell
Last internal inspection (Type and Date)
Relief valve(s) installed
Yes/No
Separate barite, bentonite /cement loading possibilities
Yes/No
Discharge line for cement should be independent from barite/bentonite Yes/No
discharge line.

F.03.3 Surge Tank for Barite/Bentonite


Capacity of each
Total Capacity
Type Weight loadcell
Last internal inspection (Type and Date)
Relief valve(s) installed

m3
m3
Yes/No

F.03.4 Surge Tank for Cement


Capacity of each
Total Capacity
Type Weight loadcell
Last internal inspection (Type and Date)
Relief valve(s) installed

m3
m3
Yes/No

No. 1
113
452
Hyd/electric
New
Yes
No. 1 & day
tank
113 & 40
452 & 80
Hyd/electric
New
Yes
Yes
Yes
No. 1
6
12
Hyd/electric
New
Yes
No. 1
2
4
Hyd/electric
New
Yes

No. 2
113

No. 3
113

No. 4
113

Hyd/electric
New
Yes
No. 2 & day
tank
113 & 40

Hyd/electric Hyd/electric
New
New
Yes
Yes
No. 3
No. 4
113

113

Hyd/electric
New
Yes
Yes
Yes

Hyd/electric
New
Yes
Yes
Yes

Hyd/electric
New
Yes
Yes
Yes

No. 2

No. 3

No. 4

No. 3

No. 4

6
Hyd/electric
New
Yes
No. 2
2
Hyd/electric
new
Yes

F.03.5 Bulk Transfer System

Independent air system for the storage and surge tanks consisting of a high-volume low-pressure compressor and air drier.
Barite transfer feed rate
MT/hr
100
Cement transfer feed rate
MT/hr
120
Air compressor quantity, make and type
4 ea EMD
Air vessel capacity
Cubic m. 2 x 5,5
C/w chemical drier/dehydration unit
Yes/No
Yes
Yes, the rig air compressors are also used for bulk
Alternatively (or as back-up) air may be drive from the main air supply Yes/No
transfer. The pressure is reduced by regulators.
and reduced to 40psi through dual pressure regulators. This system
Dedicated air vessels for the bulk system
then to be provided with separate volume tank and drier.

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION


Handling of 1 tone "Big Bags", mud/brine mixing system to be capable Yes/No
of efficiently storing, handling and loading "big bags of salt, etc.

ITEM

DESCRIPTION

UNIT

Page 25 of 28
11 June 2009
VERSION 04

Yes

CONTRACTOR'S DATA

F.04 Cementing Equipment


F.04.1 Cementing Unit (to be supplied by Other Contractor)

Cementing system to be capable to kill a well at 10,000psi (prefereble 15,00 PSI) and to be able of mixing and pumping slurries with a
density up to 2.0 kg/lt
Owner of unit currently installed
Schlumberger, free placement agreement
Make / Type
CPS-763
No. of triplex pumps
No.
2
Maximum working pressure
psi
15,000
Unit powered by (electric or diesel)
Electric
Re-circulating mixing system
Yes/No
TBA
Capacity
bbl
TBA
Liquid additive system
Yes/No
TBA
No. of tanks
No.
TBA
No. of measuring tanks
No.
TBA
No. of transfer pumps
No.
TBA
Rated capacity of each
bbl/min
TBA
Premix/batch tank
Yes/No
TBA
Capacity
bbl
TBA
Pressure recorder range
psi
TBA
Batch mixer type/capacity
bbl
TBA
Certified relief valve(s) type
Yes/No
TBA

F0.4.2 Cementing Manifold

The cementing unit to be connected to the 15,000psi WP cement/wash down/kill standpipe manifold on the drillfloor with a HP 3" ID fixed
line. The system shall be separate from the normal standpipe.
Flexible section
Rigid section
Lines from cementing unit to Rig Floor Cementing Manifold
No.
2
Outside / Min. Inside Diameter
inch
5
Working pressure
psi
15,000

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION

Page 26 of 28
11 June 2009
VERSION 04

ITEM G - ACCOMODATION
ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

G.01 Offices
G.01.1. Company drilling supervisor's office.
Complete with desk, filing cabinets, personal computer with Windows and Microsoft Office installed, printer Laser Jet 4+ or equivalent,
photocopier, and all necessary furniture.
Quantity
No.
2
Size
sq. meters
Yes
Monitor linked to a remote controlled TV camera system to observe the Yes/No
racking platform

G.01.2. Company operations engineer's office.

Complete with desk, filing cabinets, personal computer with Windows and Microsoft Office installed, printer HP 4+ Laser Jet or
equivalent, photocopier, and all necessary furniture
Quantity
No.
1
Size
sq. meters
Yes/No
Yes
G.01.3 Contractor Toolpusher office
Yes/No
Yes
G.01.4 Radio room

G.01.5 Hospital room


Hospital room containing two beds/bunks, wash basin, medical cabinet, Yes/No
dangerous drop locker.

ITEM

DESCRIPTION

Yes

UNIT

CONTRACTOR'S DATA

G.02 Living Quarters


Total accommodation for Personnel
Separate accommodation for Company staff
(Company Man, Engineer, Night Company Man).
Complete with own shower/bathroom
Accommodation for Company's Other Contractor staff
Accommodation for Contractor staff
Accommodation for Government representative
Galley
Conference/meeting rooms
Recreation rooms
Laundry/showers
Dryfood store
Refrigerator room

No.
No.

217
4

Yes/No
No.
No.
No.
No.
No.
No.
No.
No.
No.

Yes
As per contract
As per contract
As per contract
1
2
2
1 laundry, all cabins has its own bathroom
2
2

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

Page 27 of 28
11 June 2009

DRILLSHIP IADC SPECIFICATION

VERSION 04

ITEM H Miscellaneous Equipment


ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

H.01 Cranes &Handling Equipment

H.01.1. Pedestal Cranes


Quantity
Certification (API, etc.)
Manufacturer / Type
Minimum capacity and hoistings speeds
Boom Length
Line length
Maximum Rated Capacity at 25 ft radius
Maximum Rated Capacity at maximum radius
Cranes to be fitted with:
a) Hook load indicator with visual or audible overload warning device
automatically corrected for boom angle.
b) Hook fitted with safety latch.
c) Automatic brake (deadman's handle).
d) Crown savers

No.

4, knuckle boom cranes


ABS
NOV
MT-m/sec 85 MT. Hoisting speed at 17 MT 50m/min. Reduced
load 100m/min
feet
Capacity at radius of:
18 meter 85 MT, 36.5 meter 34 MT, 42.3 meter 17
MT
feet
MT
85
MT
17
Yes/No

Yes

Yes/No
Yes/No
Yes/No

Yes
Yes
Yes

No.

Ref section H.11.

H.01.2. Pipe Rack Overhead Crane


Quantity
Certification (API, etc.)
Manufacturer / Type
Rated capacity

MT

H.01.3. Riser Rack Overhead Crane


Quantity
Manufacturer / Type
Rated capacity

No.

Ref section H.11.

MT

H.01.4. BOP handling System


Quantity
Manufacturer / Type
Rated capacity

ITEM

No.
MT

DESCRIPTION

UNIT

1
NOV BOP transporter system
440

CONTRACTOR'S DATA

H.02 Helicopter Facilities


H.02.1 Helicopter Fuel Storage Tanks
Rig site quantity
Total rig site capacity

No.
gal

3 ea tanks
2,298

H.02.2 Helicopter Refueling System

Company approved helicopter refueling facility and safe storage system for min. 6m3 helicopter fuel.
Make
TBA
Storage capacity
gal
2,298

Ocean Rig P.O.Box 409, N-4067 Stavanger Norway. Telephone +47 51 96 90 00 Fax +47 51 96 90 99 E-mail oras@ocean-rig.com
www.ocean-rig.com

DRILLSHIP IADC SPECIFICATION

Page 28 of 28
11 June 2009
VERSION 04

ITEM I - Environmental Equipment


ITEM

DESCRIPTION

UNIT

CONTRACTOR'S DATA

I.01

Environmental Equipment Provided and Systems in place

I.01.2

Closed Drilling Fluids Drainage System


Draining fluids collected from:
Rotary Table
Rig Floor
Main deck
Sand Traps
Trip Tank
Mud Tank
Rate and Mouse hole

I.01.3

OBM Handling Equipment


Cutting chutes, 12" oil resistant hoses, 40' below the water line, from
cascade and shale shakers
Anti-spill metal walls for pumps and valve areas.
2 oil water separators for spider deck.
Foam system in Pit Room, Mud Pump Room and Mixing Pump area
Boot washing station as required
Manual pit volume indicator in active tank
Kick plates in front of shakers
Dump box with piping for centrifuges
Proper isolation of water system in mud pit room.
Drill pipe and drill collar rack draining system on Drill Floor.
Kick plate around stripping tank and pump.

Yes/No

Yes

Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No

Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
TBA
Yes
No
Yes
TBA
Yes
Yes