Wall panels are precast ribbed panels with Class 5000 concrete
and Grade 60 steel. Floor slab is site cast, Class 3000
concrete with Grade 60 reinforcing. All wall panel joints are
grouted with cement mortar before post tensioning. The posttensioning strands are low relaxation, seven wire strands with
an fPU of 270 ksi. and are covered with cement mortar after
post tensioning.
Application:
Assumptions:
Concurrence:
AWMFH SUPPLEMENT N5
-1-
6/8/88
6/8/88
6/8/88
Owners:
(201) 294-8943
(717) 264-9583
Fabricator:
Drawings:
Sizes:
Location:
Materials:
Wall panels are precast ribbed panels with Class 5000 concrete
and Grade 60 steel. Floor slab is site cast, Class 3000
concrete with Grade 60 reinforcing. All wall panel joints are
grouted with cement mortar before post tensioning. The posttensioning strands are low relaxation, seven wire strands with
an _fPU of 270 ksi.
Application:
Assumptions:
Concurrence:
-1-
Owners:
Designers:
Drawings:
Sizes:
Location:
Plans have been reviewed by the MNTC for compliance with the
structural aspects of National Conservation Practice Standard
31380. Design folder is on file at the MNTC.
Materials:
Top panels, beams, columns, side wall panels, and slats are
precast with Class 5000 concrete and Grade 60 steel. Floor
and rectangular footings are site cast with Class 3000
concrete and Grade 60 steel. Plain concrete wall footing is
site cast with Class 3000 concrete. The footings require a
soil bearing capacity of 3000 psf.
Application:
Assumptions:
Side walls are designed for a tank empty and full backfill
condition. Lateral earth pressure of 60 psf and lateral
wheel surcharge load of 100 psf were assumed. Solid top
panels were designed for following loadings: 100 psf cattle
and 30 psf snow or one 10,000 lb. axle plus 30 psf snow or
two 5000 lb. wheels plus 30 psf snow. Slotted top panels were
designed for 250 plf for cattle and 170 plf for swine.
Concurrence:
-1-
Owners:
Designers:
Drawings:
(313) 348-2680
Sizes:
Location:
Plans and design notes have been reviewed by the MNTC for
compliance with the structural aspects of Practice Standard
313-80. Design calculations are on file at the MNTC.
Materials:
Roof panels, wall panels. and columns are precast with Class
5000 concrete and Grade 60 steel.
Assumptions: Wall panels are designed for a tank empty and full
backfill condition. Lateral earth pressure of 60 pcf and
lateral wheel surcharge load of 100 psf are assumed. Solid
top panels are designed for 5,000 lb. wheel loads located
4.0 ft. apart.
Application:
Concurrence: The Head of the MNTC Engineer Staff concurs in the use
of these detail drawings
-1-
October 8, 1991
Designers:
Fabricators:
Drawings
and Sizes:
D810 thru -3
D8140-1 thru -3
D12080-1 thru -3
D12120-1 thru -3
D16070-1 thru -3
D16110-1 thru 3
All drawings are dated 2-85. Sheets a and 2 of each set are
Revised 7-1-85. Sheet 3 of each set is revised 5-1-85.
Location:
Plans have reviewed by the NNTC and the PA State Office for
compliance with the structural aspects of National
Conservation Practice Standard 313-80. Design folders are on
file at. the NENTC. Revi.ews were completed in July, 1985.
Materials:
Application:
Assumptions:
Concurrence:
AWMFH SUPPLEMENT N5
-1-
July, 1985
Fabricator:
Drawings:
Sizes:
Location:
Materials:
Application:
Assumptions:
Concurrence:
-1-
July, 1988
Designer:
Owner and
Drawings:
Location:
Materials:
Sizes:
Assumptions:
Application:
Concurrence:
(612) 864-5642
-1-
Designer:
Dana J. Indermuhle, PE
740-483-2501
Swiss Valley Associates, Inc.
50026 Baptist Ridge Rd., Sardis OH 43946
330-855-6453
Drawing:
Location:
Materials:
Reinforced concrete footings, floor slabs, walls, and access pads require
Grade 60 steel with Class 4000 air-entrained concrete.
Sizes:
Heights
8' & 10'
12' & 14'
12'
14'
16'
Wall Thickness
8"
10"
12"
12"
12"
Diameters
30 to 120'
30 to 120'
121 to 170'
121 to 180'
45 to 180'
Bulletin PA210-5-1
Boythrope Ltd
Weaverthrope
Marlton & Yorkshire, England
USA
Designers:
USA
Distributor:
Badger-Northland
1215 Hyland Avenue
Kaukauna, WI 54130
(414) 766-4603
Drawings:
Location:
Materials:
The tanks are made with vitreous enamel coated steel panels
and plastic capped bolts. All concrete is class 3000 with
ASTM A615 Grade 60 reinforcing steel and ASTM A82 or A185
welded wire fabric.
Sizes:
Application:
Assumptions:
Concurrence:
-1-
July, 1985
Designers:
Fabricators:
(816) 421-4232
(717) 733-0353
Drawings:
Location:
Material:
The structure contains site cast Class 3508 concrete and Grade
SC reinforcing steel.
Sizes:
Walls are 12, 10, 8ft high and 13, 11, and 9in thick
respectively. The end walls vary from 8 to 12ft long,
while the sidewalls can be any length.
Application:
Assumptions:
Concurrence:
-1-
BALMER BROS (ct) Circular, Site Cast Concrete Waste Storage Structure
Designer:
Robert D. Hyland, PE
Norton & Schmidt, Consulting Engineers
1009 Baltimore, 8th Floor
Kansas City, MO 64105
(816) 421-4232
Fabricator:
Drawings:
Location:
Materials:
Sizes (ft.):
Application:
Assumptions:
Concurrence:
-1-
July 6, 1990
816-421-4232
717-264-9186
Drawings: Sheets BE8CT1 thru BE8CT9, BE10CT1 thru BE10CT9 and BE12CT1
thru BE12CT9 for tanks with walls 8, 10, & 12 feet high with tank diameters for each
wall height ranging from 40 to 100 feet in 20 foot increments.
Location:
Calculations and drawing were reviewed by the NNTC and the PA state
office for compliance with SCS Practice Standard 313. Design folders
are on file at both reviewing offices. The reviews were completed in
September 1992.
Materials:
Sizes:
40 to 100 ft. diams. in 20 ft. increments. 8,10, & 12 ft. high walls. 7 in.
thick walls for 8 ft. walls, 8 in. thick walls for 10ft. walls and 9 in. thick
walls for 12 ft. walls.
Applications: SCS Practice Standard 313 for med. (20 yr.) service life.
Assumptions: Allowable soil bearing capacity for ftgs. 1500 psf. Walls designed
according to PCA "Circular Concrete Tanks Without Prestressing" for
hinged base connection and tank full, no backfill condition. Walls are
also adequate for full backfill, tank empty condition. Height of backfill
against tank walls shall not vary more than 4 ft. Minimum backfill of 4 ft.
is provided to assure frost protection for footing. A drainage system
under and around structure base with a pipe outlet is provided.
Allowable equipment for the walls and access pad are given in the
General Notes.
Concurrence: The Head of the NNTC Engineering Staff concurs in the use of these
Standard Detail Drawings.
Note: This sheet has been re-typed to update the company name and address. The
rest of the sheet is identical to the original, issued September 11, 1992.
-1-
BRAD BEAVER CONSTRUCTION Circular, Site Cast Concrete Waste Storage Structure
Designer:
Fabricator:
(717) 264-9186
Drawings:
Location:
Materials:
Sizes:
Application:
SCS Practice Standard 313 for med. (20 yr.) service life.
Assumptions:
Concurrence:
-1-
306-657-2816
306-664-4777
Designer:
Drawings: LBS 40', sheets 1 through 16 sealed by Enrique Tabak (sheets 2,3,
and 5 through 16 sealed on 07/0212003 and sheets 1 and 4 sealed on
07/15/2003.
Location: Calculations and drawing were reviewed for conformance with PA
Standard 313. Design data are on file in NRCS-PA state office. Review
was completed July 2003.
Materials: Fabricated steel trusses with corrosion protection.
Reinforced fabric roof material.
Grade 60 steel.
Class 4000 (psi) concrete.
Sizes:
40' roof span x required length in bays of 16' or less between roof
trusses.
2' to 8' high concrete walls in 2' increments. Intermediate sizes can be
built using the steel reinforcement for the next 2' increment.
Bulletin PA21033
Drawings:
Location:
Dimensions and steel cables have been reviewed by the NNTC for
compliance with structural aspects of National Conservation
Practice Standard 313-80. Design data is based upon the
Building Code Requirements of ACI 318-77.
Material:
Size:
Wall heights vary from 3 feet to 10 feet for low walls and
from 10 feet to 20 feet for high walls. Wall thicknesses vary
from 10 inches on low walls to 18 inches for high walls.
Application:
Assumptions:
Limitations:
Walls are not checked for sliding safety. The BAR DETAIL
typical drawings do not show T&S steel required in ACI 318 77.
Walls are not analyzed for a tank full, minimum soil backfill
condition. Corners require special design considerations when
used as containment structures.
Concurrence:
-1-
August 1, 1989
Designer:
Owners and
Fabricators:
Drawings:
Location:
Materials:
Retaining wall units are precase with 5000 psi concrete and
Grade 40 steel and Grade 50 welded wire fabric. Wall units
are bolted together with Stainless steel straps and bolts.
Floor slab is site case with 3500 psi concrete and Grade 40
steel.
Assumptions:
Application:
Concurrence:
-1-
DML Poured Walls, (DL_Cn Circular, Site Cast Waste Storage Facility
Designer:
Rodney W. Sommer, PE
816-421-4232
Norton & Schmidt, Consulting Engineers
311 East 11\1\ Avenue, North Kansas City, MO 64116
Fabricator:
Drawings:
Location:
Materials:
Reinforced concrete footings. floor slabs, walls, and access pads require
Grade 60 steel with Class 4000 air-entrained concrete.
Sizes:
Bulletin PA210-4-4
August 4. 2004
Eli Fisher Construction, (EFC.NS-06U) Circular, Site Cast Waste Storage Facility
Designer:
Everett Prewitt, PE
Norton & Schmidt, Consulting Engineers
311 East 11th Avenue, Kansas City, MO 64116
816-737-0128
Fabricator:
Drawings:
Location:
Materials:
Reinforced concrete footings, floor slabs, walls, and access pads require
Grade 60 steel with Class 4000 air-entrained concrete.
Sizes:
Diameter: 140 ft ..
Walls: 16 ft. high by 11.5 in. thick.
814-571-0976
Bulletin PA210-7-03
November 2, 2006
Eli Fisher Construction, (EFC-NS-06) Circular. Site Cast Waste Storage Facility
Designer:
Everett Prewitt, PE
Norton & Schmidt. Consulting Engineers
311 East 11th Avenue. Kansas City. MO 64116
816-737-0128
Fabricator:
Drawings:
Location:
Materials:
Reinforced concrete footings. floor slabs, walls, and access pads require
Grade 60 steel with Class 4000 air-entrained concrete.
Sizes:
814-571-0976
Bulletin PA210-6-04
Fabricator:
Sollenberger Silos
Box N
Chambersburg, PA 17201
(717) 265-9588
Drawing:
Location:
Material:
Sizes:
Application:
Assumptions:
Concurrence:
Designers:
Fabricators:
Sollenberger Silos
Box N
Chambersburg, PA 17281
(717) 265-9588
Drawings:
Location:
Material:
The circular structure consists of site cast Class 4000 psi concrete with
Grade 60 steel.
Sizes:
Application:
Assumptions:
Concurrence:
-1-
April 1986
Timothy. Royer, PE
Timber Tech Engineering, Inc
256 West Franklin Street
P.O. Box 145
Womelsdorf, PA 19567
Fabricator:
(717) 866-7565
Michael Nugent, PE
(812) 468-8502
Mid-States Engineering and Inspection, P.C.
255 South Garvin Street, Evansville, IN 47713
Fabricator:
Marvin Zimmerman
Zimmerman Harvestore Repair
P.O. Box 26
Oakland Mills, PA 17076
(717) 463-9731
Cell (717) 363-0570 (PA only)
Drawings:
No.
566100 Rev. 1
566101 Rev. 1
566102 Rev. 1
566103 Rev. 1
566104 Rev. 1
566105 Rev. 1
566106 Rev. 1
566107 Rev. 1
558995
BID1 Rev. 4
BID2 Rev. 1
BID2 Rev. 1
BID2 Rev. 1
BID3 Rev. 1
BID4
P26 Rev 2
Title
Date of P.E. Seal
42 Ft. Dia. Non-Extendable
3/21/01
62 Ft. Dia. Non-Extendable
3/5/01
81 Ft. Dia. Non-Extendable
3/5/01
101 Ft. Dia. Non-Extendable
3/21/01
42 Ft. Dia. Extendable
3/21/01
62 Ft. Dia. Extendable
3/5101
81 Ft. Dia. Extendable
3/5/01
101 Ft. Dia. Extendable
3/21/01
Cathodic Protection System
2/28/01
Foundation Section
5/9/01
6" Dia. Inlet Piping
5/9/01
8" Dia. Inlet Piping
5/9/01
12" Dia. Inlet Piping
5/9/01
Foundation Outlet Piping
5/9/01
Foundation Outlet Piping (Section A-A) 5/9/01
Slurry Tank Const. Guide (32 pages)
4/28/01
Location:
Calculations were reviewed and are on file in the NRCS-WI state office.
Drawings were reviewed for conformance with PA Standard 313 and on file in
NRCS-PA state office. Review of latest revision was completed in June 2001.
Materials:
Walls are glass fused to steel sheets, bolted together. Reinforced concrete
footings and floor slabs with grade 60 steel and Class 4000 air-entrained
concrete.
Sizes:
June 6, 2001
Fabricators:
Drawings:
Design:
Location:
Material:
Sizes:
8, 12, 16, 20 ft. high and 30, 40, 50, 60, 70, 80, 90, 100 ft.
diameters.
Calco Inc.
St. Johnsbury, VT 05819
Concurrence:
-1-
October 1984
FAX 507-288-3810
Drawings:
Sizes:
Location:
Materials:
Applications:
Assumptions;
Concurrence:
-1-
September 1990
Designers:
Fabricators:
(816) 421-4232
(717) 656-2016
Drawings:
Location:
Material:
Sizes:
Application:
Assumptions:
Concurrence:
-1-
Designers:
Fabricators:
Drawings:
Location:
Material:
Sizes:
Application:
Assumptions:
Concurrence:
-1-
Fabricators:
(816) 421-4232
(717) 656-2016
Drawings:
Location:
Material:
Application:
Assumptions:
Concurrence:
-1-
Fabricators:
(816) 421-4232
(717) 656-2016
Drawings:
Location:
Material:
Application:
Assumptions:
Concurrence:
-1-
Fabricators:
(816) 421-4232
(717) 656-2016
Drawings:
Location:
Materials:
Sizes (ft.):
Application:
Assumptions:
Concurrence:
-1-
Fabricators:
(816) 421-4232
(717) 656-2016
Drawings:
Location:
Materials:
Sizes:
Application:
Assumptions:
Concurrence:
-1-
Designer:
Rodney W. Sommer, PE
816-421-4232
Norton & Schmidt, consulting Engineers
1100 Main street, Suite 419, Kansas City, MO 64105
Fabricator:
Drawings:
Location:
Materials:
Sizes:
Applications:
Assumptions:
Concurrence:
Bulletin PA210-7-3
-1-
717-656-2016
July 1, 1997
Groffdale Concrete Walls, (GCW) Circular, Site Cast Waste Storage Facility
Designer:
816-421-4232
Everitt H. Prewitt. PE
Norton & Schmidt, Consulting Engineers
Suite 419, 1100 Main Street, Kansas City, MO 64105
717-656-2016
Drawings:
Location:
Materials:
Sizes:
Bulletin PA210-9-3
D.L Bushman, PE
Shenandoah Engineering, Ltd.
131 S. Main Street
Woodstock, VA 22664
Fabricator:
Drawings:
DRWG. NO.
#1228
b) 36 FOOT
#1236
NO. SHEETS
4
5
Location:
Materials:
Size:
a)
12'W X 28'span, 8'walls. 10'clear, 4:12 pitch.
b) 12'W x 36'span, 9'walls, 10'clear, 4:12 pitch.
Application:
Assumptions:
Concurrence:
-1-
Designer:
Timothy Royer, PE
Timber Tech Engineering
22 Denver Road
Denver. Pa 17517
Fabricator:
Drawings:
Location:
313. Design data are on file in NRCS-PA state office. Review of latest revision
was completed in October 2006.
Materials:
Pre cast wall panels 8' high with a 4' footer with 5.000psi concrete. Post
frame walls and trusses are mounted on top of the pre cast wall panels.
Sizes:
Building spans are 60' and less. Interior clearance is 16' or less.
717 -355-2361
Bulletin PA210-7-02
November 1. 2006
Keystone Concrete Products, Precast Concrete Members with Wall Support for
Rodney W. Sommer, PE
816-421-4232
Norton & Schmidt, Consulting Engineers
Suite 419,1100 Main Street. Kansas City, MO 64105
Location:
Materials:
Sizes:
4' wide panels 8',10' and 12' long. 10" x 15-1/2" beams up to 24' long.
Either of two main columns, up to 11' height, to support the ends of
beams: C-1, 10" x 15-1/2", orC-3, 12" x 17". Intermediate column C-2,
6" x 6" up to 11' height to limit beam span to 12'. 8" x 10" lintels up to
13' long, up to 12' span on side walls only (no load from beam or panel
ei~ds). Compcnent!:. m,"-y be used for multiple spans in both directions,
with grouting to accomplish full contact between abutting members as
shown in the drawings.
Christopher T. Haffner, PE
Norton & Schmidt, Consulting Engineers
1009 Baltimore, 8th Floor
Kansas City, MO 64105
(816) 421-4232
Fabricator:
Drawings:
Location:
Materials:
Sizes:
4' wire panels 8', 10'. and 12' long. 10" x 15-5/8" beams up
to 24 long. 10" x 15-1/2" and 6" x 6" columns up to 11'
long. 8" x 10" lintels up to 13' long.
Application:
Assumptions:
150 psf live load for the gang slat panels. 3 klf total load
for the beams. 1 klf total load for the lintels. 23.4 k axial
load for the 10" x 15-1/2" columns. 39 k axial load for the 6"
x 6" columns. The design assumes self-supporting walls by
others. Column footings capable of supporting 39 k are
required.
In addition to the multiple spans shown by the drawings,
structures may also be constructed using single span gang slats
with the ends of the gang slats supported by compatible
structure sidewalls. For such structures, 1) the axial load on
the gang slat panels is limited to 9 klf, 2) the required
restraint (if any) at the top of the sidewalls is not to exceed
9 klf, and 3) structure endwalls are designed so that restraint
from the gang slat panels is not required at the endwalls.
Concurrence:
-1-
May 5, 1992
Robert D. Hyland, PE
816-421-4232
Norton & Schmidt, Consulting Engineers
1100 Main Street, Suite 419, Kansas City, MO 64105
Fabricator:
Drawings:
Location:
Materials:
Sizes:
Applications:
Assumptions:
Concurrence:
Bulletin PA210-7-2
-1-
Robert D. Hyland, PE
816-421-4232
Norton & Schmidt, Consulting Engineers
1100 Main Street, Suite 419, Kansas City, MO 64105
Fabricator:
Drawings:
Location:
Materials:
Sizes:
Assumptions:
Concurrence:
-1-
May 3, 1995
Lancaster Poured Walls, (LR16LJN 1 thru 8) Circular, Site Cast Waste Storage Facility
Designer:
Rodney Sommer, PE
Norton & Schmidt, Consulting Engineers
311 East 11th Avenue, Kansas City, MO 64116
816-421-4232
Fabricator:
717-299-3974
Drawings:
Location:
Materials:
Reinforced concrete footings, floor slabs, walls, and access pads require
Grade 60 steel with Class 4000 air-entrained concrete.
Sizes:
Bulletin PA210-7-04
November 2, 2006
Fabricator:
Robert D. Hyland, PE
Norton & Schmidt, Consulting Engineers
1100 Main street, suite 419
Kansas city, MO 64105
(816) 421-4232
(717) 299-3721
Drawings:
Location:
Materials:
Sizes:
Application:
Assumptions:
Concurrence:
Bulletin PA210-6-2
-1-
816-421-4232
Fabricator:
717-291-4585
Drawings:
6/12194.
Location:
Materials:
Reinforced concrete footings, floor slabs, walls, and access pads require
Grade 60 steel with Class 4000 air-entrained concrete.
Sizes:
Fabricator:
Robert D. Hyland, PE
Norton & Schmidt, Consulting Engineers
1100 Main Street, Suite 419
Kansas city, MO 64105
(816) 421-4232
(717) 291-4585
Drawings:
Location:
Materials:
Sizes:
Diameters:
Walls:
Application:
Assumptions:
Concurrence:
-1-
Fabricator:
Robert D. Hyland, PE
Norton & Schmidt, Consulting Engineers
1100 Main Street, Suite 419
Kansas city, MO 64105
(816) 421-4232
(717) 291-4585
Drawings:
Location:
Materials:
Sizes:
Diameters:
Walls:
Application:
Assumptions:
Concurrence:
-1-
Lanco Concrete Walls, (LA12CT) Circular, Site Cast Waste Storage Facility
Designer:
Robert D. Hyland, PE
816-421 -4232
Norton & Schmidt, Consulting Engineers
Suite 419, 1100 Main Street, Kansas City, MO 64105
717-291-4585
Drawings:
Location:
Materials:
Sizes:
Bulletin PA210-8-2
Lanco Concrete Walls, (LA16UN) Circular, Site Cast Waste Storage Facility
Designer:
Rodney W. Sommer, PE
816-421-4232
Norton & Schmidt, Consulting Engineers
Suite 419, 1100 Main Street, Kansas City, MO 64105
717-291-4585
Drawings:
Location:
Materials:
Sizes:
-------~
June 11,1998
--------~ -----~-----.--~.-----.-
Timothy R. Royer, PE
717-335-2750
Timber Tech Engineering, Inc.
Suite B, 22 Denver Road, Denver, PA 17517
Fabricator:
Drawings:
Location:
Materials:
Sizes:
Cattle slat panels 4' wide x 8',10' and 12' long, 3' wide x 12' long, and
2' wide x 12' long. Solid panels 5'8" wide x 12' long. 8" x 10" beams
are 10' long, supported by 10" x 12" columns 88" to 144" high.
Components may be used for multiple spans in both directions, with
grouting and dowels to accomplish full contact between abutting
Applications:
PA Standard 313.
Assumptions:
250 plf and 3000 Ibs/axle live load for gang slat panels. 20,000
Ibs/axle live load for solid slabs. 250 plf (livestock) and no vehicle load
for pump-out panels. 640 plf and 20,000 Ibs/axle live loads for beams.
Minimum 2" bearing surface at each end of panels and beams.
"Knuckle" beam must sit in beam pocket on tank wall to be designed by
others. Extra wall reinforcement at "knuckle" for 13,034 Ibs load (45 pcf
soil load on max. 12' wall) is shown in the drawing. Maximum 1064 plf
lateral wall load on ends of panels. The drawing includes a footing
design capable of supporting the 21.124 k column load on 3000 psf
bearing soil.
Concurrence:
717-866-7153
November 3, 2005
Fabricators:
Drawings:
Design:
Dated 4-28-83
Location:
Material:
Sizes:
Application:
Assumptions:
Concurrence:
-1-
May, 1990
Designers:
Drawings:
Location:
Material:
Sizes:
Application:
Assumptions:
Limitations:
Concurrence:
-1-
June 7, 1989
Location:
Materials:
Sizes:
Bulletin PA210-9-4
Owners:
(319) 928-6987
Drawings:
Sizes:
Materials:
Location:
Application:
Concurrence:
-1-
Designer:
Drawings:
Sizes:
Location:
Design notes and plans have been reviewed by the MNTC for
compliance with the structural aspects of Conservation
Practice Standard 313-80. Design folders are on file at
the MNTC.
Materials:
Walls, footings and floors are site cast with Class 3000
concrete and Grade 60 steel.
-1-
Rodney W. Sommer, PE
816-421-4232
Norton & Schmidt, Consulting Engineers
Suite 419, 1100 Main Street, Kansas City, MO 64105
Fabricator:
Drawings:
PC8CT1 thru 11 (dated 4/19/91), revised 9/25/91, 1/8/92, and 3/10/97 for
8 foot walls.
PC10CT1 (sealed 6/25/99) thru PC10CT4 and PC10CT11 revised 6/25/99;
PC10CT5 thru 10 dated 4/19/91; and PC10CT12 thru 17 dated 6/25/99 for 10
foot walls.
PC12CT1 (sealed 4/30/99), PC12CT3 and PC12CT4 revised 9/2/98
PC12CT2 and PC12CT11 revised 4/30/99; PC12CT5 thru 10 revised 2/11/91;
PC12CT12 and 13 dated 3/11/97; PC12CT14 dated 8/19/98; and PC12CT15
thru 17 dated 4/30/99 for 12 foot walls.
PC16CT1 thru 11 (dated 12/28/92), and PC16CT20 thru 30 (dated 2/15/00
and sealed 2/18/00) for 16 foot walls.
Location:
Materials:
Reinforced concrete footings, floor slabs, walls, and access pads require
Grade 60 steel with Class 4000 air-entrained concrete.
Sizes:
Applications:
Assumptions:
Walls are designed for full backfill, structure empty and structure full,
minimum backfill conditions. Lateral earth pressure of 45 psf and 100psf
surcharge are assumed. The access pads, proportioned to eliminate lateral
surcharge loads an the wall, are designed for 2 wheels of 7.5 k each. The
alternate wall steel in lieu of access pad is designed for 2 wheels of 10k each.
Minimum required soil bearing capacities are 1.0 kst under floor slab, and 2.0
ksf + (110 pst multiplied by the depth below finished grade) for the footing.
Backfill for frost protection is required. Design assumes a foundation drain as
shown on drawings. Height of backfill against the structure walls shall not vary
more than 4 feet. Structure diameters between those shown may be used
provided the reinforcing steel for the next larger diameter is used.
Concurrence:
The State Conservation Engineer concurs in the use of these standard detail
drawings.
Bulletin PA210-0-4
Precise Concrete Walls, (PCCT) Circular, Site Cast Waste Storage Facility
Designer:
RodneyW. Sommer, PE
8164214232
Norton & Schmidt, Consulting Engineers
Suite 419, 1100 Main Street, Kansas City, MO 64105
Location:
Materials:
Sizes:
Precise Concrete Walls, (PCCT) Circular, Site Cast Waste Storage Facility
Designer:
Rodney W. Sommer, PE
816-421-4232
Norton & Schmidt, Consulting Engineers
Suite 419,1100 Main Street, Kansas City, MO 64105
717-354-2780
601 Overly Grove Rd., New Holland, PA 17557
Drawings:
Location:
Materials:
Sizes:
Robert D. Hyland, PE
816-421-4232
Norton & Schmidt, Consulting Engineers
1100 Main Street, Suite 419, Kansas City, MO 64105
Fabricator:
Drawings:
Location:
Materials:
Sizes:
Concurrence:
Bulletin PA210-7-1
Designer:
Fabricator:
(717) 354-2780
Drawings:
Location:
Materials:
Sizes:
Application:
Assumptions:
Concurrence:
-1-
Precise Concrete Walls, (PCUE) Circular, Site Cast Waste Storage Facility
Designer:
Rodney W. Sommer, PE
8164214232
Norton & Schmidt, Consulting Engineers
Suite 419,1100 Main Street, Kansas City, MO 64105
7173542780
601 Overly Grove Rd., New Holland, PA 17557
Drawings:
Location:
Materials:
Sizes:
Bulletin PA210-9-2
----------
Jesigner:
Fabricator:
Robert D. Hyla:1d, PE
Norton 0. Schmidt, Consulting Engineers
1100 Main Street, Suite 419
Kansas C!ty, MO 64185
(816) 421-4232
PREC:SE CO:1crete Walls
6::' CrJer ly Road
(717) 354-2788
Location:
Materials:
Sizes:
Diameters:
'tlalls:
-1-
Precise Concrete Walls, (PC16UE) Circular, Site Cast Waste Storage Facility
Designer:
Rodney W. Sommer, PE
816-421-4232
Norton & Schmidt. Consulting Engineers
Suite 419, 1100 Main Street, Kansas City. MO 64105
Fabricator:
Drawings:
Location:
Materials:
Reinforced concrete footings. floor slabs, walls, and access pads require
Grade 60 steel with Class 4000 air-entrained concrete.
Sizes:
Bulletin PA210-4-3
May 12,2004
RIBCA3T
C~;c~:ar,
Precast Concrete,
~aste
Designer:
?abricators:
R~bcas:
S=orage
Stryct~res
Systems Co,
.:":<ron. ?A
\-::)
':'7501
359-3324
Drawings:
3-10:')0,
Location:
Material:
Sizes:
-1-
October, 1984
Designer &
Fabricator:
Drawings & Drawing numbers and nominal structure sizes are as follows:
Sizes:
Shell Assembly
Height (ft)
Drawing No.
Diameter (ft)
42
14, 19,23 & 28
261283
261284
14, 19,23 & 28
62
14, 19,23 & 28
81
261285
101
261286
14,19,23 & 28
120
10, 14, 19,23 & 28
262358
261282
261289
257014
Note: The minimum height shown for 42 thru 101 ft diameter structures is 14
ft. It is permissible to eliminate the bottom row of shell sheets from the 14 ft
height models to produce a 19 ft nominal structure height if desired. All other
requirements remain the same as for the 14 ft height model.
Each structure is furnished with a nameplate which identifies the Model No.,
structure size (diameter and height), and a Serial No ..
Materials:
The structure shell consists of glass fused to steel sheets that are bolted
together. Footing walls and floor are reinforced concrete. Cathodic protection
is provided by zinc anodes electrically connected to the shell sheets and the
floor and footing reinforcement.
Assumptions: The shell design assumes above ground application only. Footing sizes are
designed for a maximum allowable bearing capacity of 2000 psf. Footing
strength design is based on a minimum 3000 psi concrete strength. Wind
design considerations are based on a wind speed of 80 mph.
Applications: National Conservation Practice Standard 313 "Waste Storage Structure" for
Medium (20 year) service life.
Concurrence: December 8, 1993. The Head, Midwest NTC Engineering Staff concurs in
the use of these detail drawings.
Note: This sheet was re-typed to update the company name. The rest of the sheet is identical
to the original.
Fabricator:
Drawing &
Sizes:
(815) 756-1551
(717) 354-4051
Diameter (ft)
42
62
81
101
120
Height (ft)
14, 19, 23, & 28
14, 19, 23, & 28
14, 19, 23, &.28
14, 19, 23, & 28
10, 14, 19,21 & 28
261182
261289
257014
Note: The minimum height shown for 42 thru 101 ft diameter structures is 14 ft.
It is permissible to eliminate the bottom row of shell sheets from the 14 ft
height models to produce a 10 ft nominal structure height if desired. All other
requirements remain the same as for the 14 ft height model.
Each structure is furnished with a nameplate which identifies the Model No.,
structure size (diameter and height), and a Serial No.
Materials:
The structure shell consists of glass fused to steel sheets that are bolted
together. Footing walls and floor are reinforced concrete. Cathodic protection
is provided by zinc anodes electrically connected to the shell sheets and the
float and footing reinforcement.
Assumptions:
The shell design assumes above ground application only. Footing sizes are
designed for a maximum allowable bearing capacity of 2000 psf. Fooling
strength design is based on a minimum 3000 psi concrete strength. Wind design
considerations are based a wind speed of 80 mph.
Application:
Concurrence:
December 8, 1993. The Head. Midwest NTC Engineering Staff concurs in the
use of these detail drawings.
Designer:
Fabricator:
Drawing &
Sizes:
(815) 756-1551
(717) 354-4051
Diameter (ft)
42
62
81
101
Height (ft)
14, 19, 23, & 28
14, 19, 23, & 28
14, 19, 23, &.28
14, 19, 23, & 28
Application:
SCS Practice Standard 313 for med. (20 yr.) service life.
Assumptions:
The shell design assumes above ground application only. Footing sizes are
designed for a maximum allowable bearing capacity of 2000 psf. Fooling
strength design is based on a minimum 3000 psi concrete strength. Wind design
considerations are based a wind speed of 70 mph.
Concurrence:
-1-
December 6, 1990
Designers:
Fabricators:
(519) 634-8453
Sollenberger Silos
P.O. Box N
Chambersburg, PA 17201
(717) 264-9588
Drawings:
Location:
Materials:
Sizes:
Application:
Assumptions:
Concurrence:
-1-