Você está na página 1de 51

ELECTRONICS CORPORATION OF TAMILNADU LTD

PROPOSED DATA CENTRE AT PERUNGUDI


(5) Drain
S.No.

a)

a)

Description

Unit

Qty

Cum

2300

Cum

10

Cum

160

Earthwork excavation in all classes of soils such as hard stiff clay,


stiff black cotton, hard red earth, shales, murram etc. except hard
rock requiring blasting for foundation and depositing within the
campus with a lead of upto 100 meters in levelled layer with all
leads and lifts including cost of all labour materials equipment and
all other incidental charges like cribs, sheeting, shoring, bracing,
providing protective bunds, cofferdams, baling out water and other
items which may be necessary or convenient to the successful
completion of the excavation to the bottom of the drain removing of
all logs, stumps, grubs and other deleterious matter and obstruction
including trimming bottom of excavation, cost of any cleaning
grubbing removing slips and blows if any and any surplus materials
which may have to be thrown up during the process of excavation
including setting out all labour materials, hire and fuel charges for all
tools and plants, equipment, safe guards, and incidental necessary
to complete the work and subsequent removal and cleaning the
excavated materials protective bunds and cofferdams etc., as per
Standard Specification.

Upto 2.0 Metre depth below average ground level.


Exavation for foundatios in hard rock measured in solid rock,
requiring blasting including all required blasting works and stacking
the blasted rock for pre-measurements. The work includes refilling
of foundation with selected earth all as directed by the Engineer-inCharge and as per standard specification.
Upto 2.0 Metre depth below average ground level.
Providing and laying plain cement concrete 1:4:8 (one part of
cement,four part of sand and eight part of stone jelly)mix using
40mm size hard broken blue granite stone jelly for foundation and
plinth beam base all as per standard specification.

Rate
Both figures and in words

Amount (Rs)

Providing & laying cast-in-situ controlled reinforced concrete of


the following grades using 20 mm and down size coarse graded
machine crushed hard stone aggregate including designing the mix,
weigh batching, mechanical mixing, transporting and placing at all
lifts, vibrating, consolidating, curing and finishing smooth as required
all exposed faces, complete for the following RC structural and other
elements including centering, shuttering, form work either straight,
curved, plain, tapered or sloped, supplying and mixing admixtures,
dewatering wherever necessary, the cost of all complete
materials, labour, all leads and lifts, tools, plant and machineries,
hire and fuel charges and all other incidental charges etc

Specifications, drawings and as directed, but excluding steel


reinforcement, IRC mesh, insert plates which will be paid for
separately under relevant items.The rates quoted shall hold good for
all foundations at any depth, flooring, all floors, heights, levels,
elevation, below ground level, basement, trenches, pits, tunnels etc.
The designing of concrete mix for different grades of controlled
concrete should be done in accordance with latest IS - SP 23.
(Hand book on concrete mix design) in the field laboratory and the
same should be got approved by the Engineer. Grade of concrete
for all concrete works specified in BOQ should be invariably
followed :
M-25 Grade :

a
5

a
b
7

upto Ground lvl

cum

150

MT

20

for Plain surfaces & Slabs

sqm

for walls

sqm

155
2040

sqm

1120

Supply, fabricate by straightening, cutting, bending to size, place in


position and tie with 18G binding wire for steel reinforcement for all
RCC works using RTS bars of Fe 500 grade for steel
reinforcements all as per standard specification
Providing and erecting centering for all RCC members with steel
centering sheets/ plywood sheets, including strutting propping etc.
as required and de-centering after the specified dates for the
concerned RCC members and clearing out all the centering
materials etc, complete all as per standard specification.

Providing and plastering with cement mortar 1:3(one part of cement


and three part of sand ), 12mm thick on the exposed surfaces of
RCC members including hacking the concrete surface for proper
bonding etc. complete all as per standard specification.

Supplying and providing following size NP3 class RCC pipes

with required collars and laying and fixing the RCC pipes
including 100mm thk PCC bed and labour charges for all
conveyance hoisting and placing the pipes and collars in
position as directed by the EIC and packing and pointing the
joints with cement mortar 1:2 and all other incidental charges
etc., complete

a) 300 mm dia., pipes


b) 450 mm dia., pipes
Cement Concrete Solid Block Masonry in cement mortar
1:5 ( one cement and five coarse sand ) 400mm thick upto
Plinth level using precast machine moulded blocks at all
levels using standard size of 390 x 190 mm of solid cement
concrete blocks with minimum compressive strength of
50Kg/Sq.cm conforming to IS 2185 or equivalent BS
including all scaffolding, staging, curing, and all leads etc.
complete
and
as
directed
by
the
department
officers/Architect.
Total C/o to Summary : Rs.

RM
RM

5
10

Cum

112

Você também pode gostar