Você está na página 1de 68

Short Form Catalogue

LS Series
Limit Switches

LS Series Limit Switches


Foot Switches

Contents
Panorama ................................................................................................................................ 2
Limit Switches - Plastic Casing and Metal Casing.................................................................. 12
Safety Limit Switches - Plastic Casing and Metal Casing ...................................................... 42
Limit Switches with Latch and Manual Reset - Plastic Casing and Metal Casing .................. 56
Foot Switches with Cover and Mini Foot Switches................................................................. 62

1
1SBC141157C0202

LS Series Prewired
30

mm width

Metal Casing IP67


Plastic Casing IP67 Double insulation

LS2

...
M = Metal casing
P = Plastic casing
0 = Cable output left / right
1 = Cable output bottom

Type

LS2..M11, LS2..P11

LS2..M12, LS2..P12

LS2..M13, LS2..P13

LS2..M14, LS2..P14

Brass plain plunger

Steel roller plunger

Plastic roller plunger

Cross steel roller plunger

Actuator
Action type

CENELEC Conformity / Positive opening operation

LS2..M41, LS2..P41

LS2..M42, LS2..P42

LS2..M45, LS2..P45

LS2..M46, LS2..P46

LS2..M51, LS2..P51

LS2..M54, LS2..P54

14 plastic roller lever

14 steel roller lever

18 plastic roller
with bent lever

18 steel roller
with bent lever

Adjustable 18
plastic roller lever

Adjustable 18
steel roller lever

35

LS2..M11, LS2..P11

LS2..M12, LS2..P12

LS2..M14, LS2..P14

LS2..M21, LS2..P21

Brass plain plunger

Steel roller plunger

Cross steel roller plunger

mm width

Metal Casing IP67


Plastic Casing IP67 Double insulation

LS2

...
M = Metal casing
P = Plastic casing
5 = Cable output left / right
6 = Cable output bottom

As the range is very large, the products shown there are the most
common. For the complete range, please consult us.

Type
Actuator

Brass plain plunger


with xing nuts

Action type

CENELEC conformity / Positive opening operation


2
1SBC141157C0202

Limit Switches - IP67

LS2..M15, LS2..P15

LS2..M21, LS2..P21

LS2..M22, LS2..P22

LS2..M23, LS2..P23

LS2..M24, LS2..P24

LS2..M25, LS2..P25

Cross plastic roller plunger

Brass plain plunger


with xing nuts

Steel roller plunger


with xing nuts

Plastic roller plunger


with xing nuts

Cross roller plunger


with xing nuts

Cross plastic roller plunger


with xing nuts

LS2..M71, LS2..P71

LS2..M72, LS2..P72

LS2..M73, LS2..P73

LS2..M78, LS2..P78

LS2..M91, LS2..P91

LS2..M92, LS2..P92

Adjustable 3
steel rod lever

Adjustable 3
bre-glass rod lever

Adjustable 6
polyamide rod lever

Adjustable 3
steel rod lever

Spring rod

Flexible rod with insulated end

LS2..M22, LS2..P22

LS2..M24, LS2..P24

Steel roller plunger


with xing nuts

Cross steel roller lever


with xing nuts

LS2..M41, LS2..P41

LS2..M51, LS2..P51

LS2..M71, LS2..P71

14 Plastic roller lever

Adjustable 18
plastic roller lever

LS2..M91, LS2..P91

Adjustable 3
steel rod lever

Spring rod

3
1SBC141157C0202

LS Series Limit Switches


Plastic Casing IP65 - Double insulation

30
60

mm
mm
Width

LS3
LS7
Electrical
Connection

P...
P...
0
1
=
3
5

= Pg 13.5
= Pg 11
M16 x 1.5
= M20 x 1.5
= 1/2" NPT

Type
Actuator

LS..P10, LS..P11

LS..P12, LS..P13

LS..P14

LS..P31

Plain plunger

Roller plunger

Plain plunger

Roller lever

Action type

CENELEC conformity / Positive opening operation

EN 50047

EN 50047

EN 50047

EN 50047

Nota: For LS7 P... (60 mm width) compatible with EN 50047 (fixing)

LS..P51, LS..P53

LS..P52

LS..P55

LS..P61

LS..P62

LS..P71, LS..P72

Adjustable roller lever

Adjustable roller lever

Adjustable roller lever

Flexible lever

Flexible lever

Adjustable rod lever

Plastic Casing IP65 - Double insulation

40

mm
Width

LS4
Electrical
Connection

P...
0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

As the range is very large, the products shown here are the
most common. For the complete range, please consult us.

Type
Actuator

LS..P11

LS..P13

LS..P31

LS..P41

Plain plunger

Roller plunger

Roller lever

Roller lever

Action type

CENELEC conformity / Positive opening operation


4
1SBC141157C0202

EN 50041

EN 50041

EN 50041

Plastic Casing IP65

LS..P32

LS..P35

LS..P38

LS..P41, LS..P43

LS..P42

LS..P45, LS..P46

Roller lever

Roller lever

Adjustable roller lever

Roller lever

Roller lever

Roller lever

EN 50047

EN 50047

LS..P73

LS..P74

LS..P78

LS..P91

LS..P92

LS..P98B11-A

Adjustable rod lever

Adjustable rod lever

Adjustable rod lever

Flexible rod

Flexible rod

Pull action

LS..P44

LS..P51

Roller lever

LS..P54

LS..P61

Adjustable roller levers

LS..P72

LS..P91

Adjustable exible and rigid rod levers

EN 50041

Flexible rod

5
1SBC141157C0202

LS Series Limit Switches


Metal Casing IP66

30
60

mm
mm
Width

LS3
LS7

M...
M...
0
1
=
3
5

Electrical
Connection

= Pg 13.5
= Pg 11
M16 x 1.5
= M20 x 1.5
= 1/2" NPT

Type
Actuator

LS..M11

LS..M12, LS..M13

LS..M14

LS..M31

Plain plunger

Roller plunger

Plain plunger

Roller lever

Action type

CENELEC conformity / Positive opening operation

EN 50047

EN 50047

EN 50047

EN 50047

Nota: For LS7 M... (60 mm width) compatible with EN 50047 (fixing)

LS..M51, LS..M53

LS..M52

LS..M55

LS..M61

LS..M62

LS..M71, LS..M72

Adjustable roller lever

Adjustable roller lever

Adjustable roller lever

Flexible lever

Flexible lever

Adjustable rod lever

Metal Casing IP66

40

mm
Width

LS4
Electrical
Connection

M...
0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

As the range is very large, the products shown here are the
most common. For the complete range, please consult us.

Type
Actuator

LS..M11

LS..M13

LS..M21

LS..M22

LS..M31

Plain plunger

Roller plunger

Plain plunger

Roller plunger

Roller lever

Action type

CENELEC conformity / Positive opening operation


6
1SBC141157C0202

EN 50041

EN 50041

EN 50041

EN 50041

Metal Casing IP66

LS..M32

LS..M35

LS..M38

LS..M41, LS..M43

LS..M42

LS..M45, LS..M46

Roller lever

Roller lever

Adjustable roller lever

Roller lever

Roller lever

Roller lever

EN 50047

EN 50047

LS..M73

LS..M74

LS..M78

LS..M91

LS..M92

LS..M98B11-A

Adjustable rod lever

Adjustable rod lever

Adjustable rod lever

Flexible rod

Flexible rod

Pull action

LS..M41

LS..M51

Roller lever

EN 50041

LS..M54

LS..M61

Adjustable roller levers

LS..M72

LS..M91

Adjustable exible and rigid rod levers

EN 50041

Flexible rod

7
1SBC141157C0202

LS Series Limit Switches


Safety Limit Switches
P = Plastic casing
M = Metal casing

30

mm
Width

LS3
Electrical
Connection

40

mm
Width

...
0
1
2
3
5

=
=
=
=
=

Pg 13.5
Pg 11
M16 x 1.5
M20 x 1.5
1/2" NPT

LS4

...

Electrical
Connection

0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

Limit Switches

LS3..P80..-S

Operating head options:

LS3..M80..-S

LS3..P81..-S

Adjustable head

LS3..M81..-S

LS4..P80..-S

Pivoting head

LS4..M80..-S

Adjustable head

Action type: Translation with small latch (key)

Positive opening operation

Keys
s

Keys
Keys for LS3... limit switches

LSA30P03

LSA30P04

Keys for LS4... limit switches


Actuator

Fixing

LSA30P05

LSA30P06

LSA30P07

LSA30P08

LSA30P09

LSA40X05

LSA40X06

LSA40X07

LSA40X08

LSA40X09

Right
angle key

Straight
key

Right
angle key

Straight
key

Right angle
key + shock
absorber

Straight
key + shock
absorber

Adjustable
angle key

22 mm

22 mm

13 mm

13 mm

15 mm

15 mm

40 mm

Limit Switches with Latch and Manual Reset


P = Plastic casing
M = Metal casing

30

mm
Width

LS3
Electrical
Connection

Limit Switches
Actuator:
Action type

Positive opening operation


8
1SBC141157C0202

...
0
1
2
3
5

=
=
=
=
=

Pg 13.5
Pg 11
M16 x 1.5
M20 x 1.5
1/2" NPT
LS3..P11..-R

LS3..M11..-R

Galvanized steel plain plunger

LS3..P12..-R

LS3..M12..-R

Galvanized steel roller plunger

Plastic Casing IP65

and Metal Casing IP66

Safety Limit Switches with Pulling Cable


P = Plastic casing
M = Metal casing

30

mm
Width

LS3
Electrical
Connection

40
60

mm
mm
Width

...
0
1
2
3
5

LS4
LS6
Electrical
Connection

=
=
=
=
=

Pg 13.5
Pg 11
M16 x 1.5
M20 x 1.5
1/2" NPT

...
...

M
M

0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

Limit Switches

LS3..P98..-SCR

Actuator:

LS3..M98..-SCR

LS4..M98..-SCR

By red cable

LS6..M98..-SCR

By red cable

Action type: Pulling

Positive opening operation

Safety Limit Switches


with Rotative Axis or with Lever
P = Plastic casing
M = Metal casing

30

mm
Width

LS3
Electrical
Connection

...
0
1
2
3
5

=
=
=
=
=

Pg 13.5
Pg 11
M16 x 1.5
M20 x 1.5
1/2" NPT

Limit Switches

LS3..P75..-S

Actuator:

LS3..M75..-S

LS3..P76..-S

LS3..M76..-S

Galvanized steel rotative axis

Stainless steel rotative axis

Action type

LS3..P77..-S

LS3..M77..-S

Galvanized steel lever

Positive opening operation

LS3..P13..-R

LS3..M13..-R

Plastic roller plunger

LS3..P31..-R

LS3..M31..-R

LS3..P32..-R

LS3..M32..-R

Plastic roller lever on galvanized steel plunger

LS3..P41..-R

LS3..M41..-R

Rotary lever with plastic roller

9
1SBC141157C0202

Foot Switches with Cover

Double insulation
IP65
Foot Switches
Actuator:

IPS..1..

IPS..2..

IPS..3..

Free movement

Locked in neutral position

Latched in low position

Action type

CENELEC conformity / Positive opening operation

Mini Foot Switches

IP40
Mini Foot Switches
Actuator:

IPM..1..

IPM..2..

Free movement

Free movement

Action type

CENELEC conformity / Positive opening operation

10
1SBC141157C0202

LS Series Limit Switches


Foot Switches

Contents
Limit Switches
Description .............................................................................................................................. 12
Ordering Details....................................................................................................................... 15
Travel and Operation Diagrams ............................................................................................... 23
Technical Data ......................................................................................................................... 24
Selection Table and Functional Characteristics ...................................................................... 26

Safety Limit Switches


Description .............................................................................................................................. 42
Ordering Details....................................................................................................................... 45
Travel and Operation Diagrams ............................................................................................... 48
Technical Data ......................................................................................................................... 50
Selection Table and Functional Characteristics ...................................................................... 51

Limit Switches with latch and manual reset


Description .............................................................................................................................. 56
Ordering Details....................................................................................................................... 57
Travel and Operation Diagrams ............................................................................................... 58
Technical Data ......................................................................................................................... 59
Selection Table and Functional Characteristics ...................................................................... 60

Foot Switches
Description .............................................................................................................................. 62
Ordering Details....................................................................................................................... 63
Technical Data ......................................................................................................................... 64

11
1SBC141157C0202

LS20P ... LS26P.. and LS20M ... LS26M..


Prewired Limit Switches
Double Insulation

- Plastic Casing IP67 or Metal Casing IP67

Applications
Easy to use, electromechanical limit switches offer specic qualities:

Visible operation.
Able to switch strong currents (5 A conventional thermal current).
Electrically separated contacts (Zb shape).
Contact blocks with positive opening operation of the "N.C." normally closed contact(s) (symbol
Precise operating points (consistency).
Immune to electromagnetic disturbances.

).

They are exceptional detection devices thanks to these characteristics:

Presence/absence.
Positioning and travel limit.
Objects passing/counting.

Description
LS20P ... LS26P limit switches, made of fibre-glass reinforced UL-V0 thermoplastic material, sealed with epoxy resin at the base on the body, offer
double insulation and a degree of protection IP67.
LS20M ... LS26M limit switches, made of zinc alloy (zamack), sealed with epoxy resin at the base on the body, offer a degree of protection IP67.
The casings come in 2 dimensions: LS20 ... LS21, 30 mm width,

LS25 ... LS26, 35 mm width.

Mounting the casing:


2 x M4 screws on the top part

A variety of operating heads:


Plain plunger
Roller plunger
Roller lever, adjustable or not, etc.
Assembled using 2 x 3 screws for LS20P...LS26P
Assembled using 2 x M3 screws for LS20M...LS26M

Electrical connection:
Cable output left/right or cable output bottom:
for LS20P...LS26P
- cable IEC 20/22 II PVC 4 x 0.75 mm2
- cable UL 62 PVC 4 x AWG 18
for LS20M...LS26M
- cable IEC 20/22 II PVC 5 x 0.75 mm2
- cable UL 62 PVC 5 x AWG 18

Casing:
30 mm or 35 mm width

Standard

length: 1 m (other lenghts on request)


outputs (on request):
- connector M12 or 7/8" NPT
- cable with end connector

Other

Contact blocks:
Contact configuration: 1 N.O. + 1 N.C.
Positive opening operation
Snap action or slow action
Zb shape: the 2 contacts are electrically separated

Type

Compounding

Example:

L S

2 0

1 1

B 1 1

0 1

Example:

L S

2 5

5 1

D 1 1

0 2

L S

Cable length:
01 ........... 1 m
02 ........... 2 m
03 ........... 3 m
05 ........... 5 m
10 ........... 10 m (Max. for UL cable)
11 ... 99 (for IEC cable only)

Limit Switch .............................................................. LS

Casing width: 30 mm ................................................................... 2


1 cable output left / right .................................................................... 0
1 cable output bottom ........................................................................ 1

Casing width: 35 mm ................................................................... 2


1 cable output left / right .................................................................... 5
1 cable output bottom ........................................................................ 6

Plastic casing....................................................................................................P
Metal casing .................................................................................................... M
Operating heads
Codes ......................................................................................................................... 10 ... 98

12
1SBC141157C0202

with epoxy resin for IP67 protection

degree

P ........... cable IEC 20/22 II - PVC


U ........... cable UL 62 - PVC
Contact types:
11 ........... 1 N.O. + 1 N.C. contacts

Snap action:
B ........... Zb Snap
Dependent (slow) action:
D ........... Zb Non-overlapping late make

LS3..P.., LS4..P.. and LS7..P.. Limit Switches


Double Insulation

- Plastic Casing IP65

Applications
Easy to use, electromechanical limit switches offer specic qualities:

Visible operation.
Able to switch strong currents (10 A conventional thermal current).
Electrically separated contacts.
Contact blocks with positive opening operation of the "N.C." normally closed contact(s) (symbol
Precise operating points (consistency).
Immune to electromagnetic disturbances.

).

They are exceptional detection devices thanks to these characteristics:

Presence/absence.
Positioning and travel limit.
Objects passing/counting.

Description
LS3..P..., LS4..P... and LS7..P..., limit switches, which are made of fibre-glass reinforced UL-V0 thermoplastic material, offer double insulation
and a degree of protection IP65.
The casings come in 3 dimensions:

LS3..P... 30 mm width,

LS4..P... 40 mm width, LS7..P... 60 mm width.

Cover:
Closed using 1 x 3 screw for 30 & 60 mm width
Self clipping closure for 40 mm width
One piece sealing gasket to ensure tightness

A variety of operating heads:


Plain plunger
Roller plunger
Roller lever, adjustable or not, etc.
Assembled using 4 x 3 screws for 30 & 60 mm width
Assembled using 4 x 4 screws for 40 mm width

Mounting the casing:


2 x M4 screws for 30 mm width
2 or 4 x M5 screws for 40 mm width
2 or 4 x M4 screws for 60 mm width

Casing:
30 mm width with standardized dimensions according
to EN 50047
40 mm width with standardized dimensions according
to EN 50041
60 mm width compatible with EN 50047 (Fixing)

Type

Example:

L0906D

Electrical connection:
1 (LS30P), 1 (LS40P) or 2 (LS70P) cable inlets for
Pg 13.5 cable gland
1 (LS31P) or 2 (LS71P) cable inlets for Pg 11 cable gland
1 (LS32P) or 2 (LS72P) cable inlets for ISO 16 cable gland
1 (LS33P), 1 (LS43P) or 2 (LS73P) cable inlets for
ISO 20 cable gland
1 (LS35P) cable inlet by 1/2" NPT plastic adaptor
1 (LS45P) cable inlet for 1/2" NPT cable gland
1 (LS75P) cable inlet by 1/2" NPT plastic adaptor +
1 cable inlet Pg11 for additional 1/2" NPT plastic
adaptor (on request)
Suitable for conduit connection only with use of adaptor sleeve optionally provided by manufacturer. (on
request)

Block of 2 contacts:
Contact configuration: 1 N.O. + 1 N.C., 2 N.O., 2 N.C.
Positive opening operation
Snap action or slow action
The 2 contacts are electrically separated
Connecting terminals:
M3.5 (+,) pozidriv 2 screw
(Screw head with captive cable clamp)
Markings conform with IEC 60947-1, IEC 60947-5-1,
EN 50005 and EN 50013 standards

L S

7 2

L S
Limit Switch .................................................................................LS
Casing width: 30 mm ..................................................................................... 3
1 cable inlet for Pg 13.5 cable gland ....................................................................0
1 cable inlet for Pg 11 cable gland .......................................................................1
1 cable inlet M16 x 1.5 for ISO 16 cable gland ....................................................2
1 cable inlet M20 x 1.5 for ISO 20 cable gland ....................................................3
1 cable inlet by 1/2" NPT plastic adaptor delivered not mounted........................5

Casing width: 40 mm ..................................................................................... 4


1 cable inlet for Pg 13.5 cable gland ....................................................................0
1 cable inlet M20 x 1.5 for ISO 20 cable gland ....................................................3
1 cable inlet for 1/2" NPT cable gland ..................................................................5

Casing width: 60 mm ..................................................................................... 7


2 cable inlets for Pg 13.5 cable gland ..................................................................0
2 cable inlets for Pg 11 cable gland .....................................................................1
2 cable inlets M16 x 1.5 for ISO 16 cable gland ...................................................2
2 cable inlets M20 x 1.5 for ISO 20 cable gland ...................................................3
1 cable inlet by 1/2" NPT plastic adaptor + 1 cable inlet Pg 11 for additional
1/2" NPT plastic adaptor (on request) ..................................................................5

4 1

B 1 1

P
Contact types:
11 ............ 1 N.O. + 1 N.C. contacts
20 ............ 2 N.O. contacts
02 ............ 2 N.C. contacts

Snap action:
B ............Zb Snap (except for 2 N.O. contacts)
Dependent (slow) action:
L .............Slow / Simultaneous
D ............Zb Non-overlapping late make
C ............Zb Overlapping early make

Operating heads: (see panorama)


10 ... 98 ..........................................................................................................................Codes

P ........................................................................................................................................Plastic casing

13
1SBC141157C0202

LS3..M.., LS4..M.. and LS7..M.. Limit Switches


Metal Casing IP66
Applications
Easy to use, electromechanical limit switches offer specic qualities:

Visible operation.
Able to switch strong currents (10 A conventional thermal current).
Electrically separated contacts.
Contact blocks with positive opening operation of the "N.C." normally closed contact(s) (symbol
Precise operating points (consistency).
Immune to electromagnetic disturbances.

).

They are exceptional detection devices thanks to these characteristics:

Presence/absence.
Positioning and travel limit.
Objects passing/counting.

Description
Limit switches, LS3..M.. and LS7..M.., which are made of zinc alloy (zamack), have a degree of protection IP66.
Limit switches, LS4..M.., which are made of aluminium alloy, have a degree of protection IP66.
The casings come in 3 dimensions:

LS3..M... 30 mm width,

LS4..M... 40 mm width,

Cover:
Closed using 3 x M3 screws for 30 mm width
Closed using 4 x M3 screws for 60 mm width
Closed using 2 x M4 screws for 40 mm width
One piece sealing gasket to ensure tightness

LS7..M... 60 mm width.

A variety of operating heads:


plunger
Roller plunger
Roller lever, adjustable or not, etc.
Assembled using 4 x M3 screws for 30 & 60 mm width
Assembled using 4 x M4 screws for 40 mm width
Plain

Mounting the casing:


x M4 screws for 30 mm width
2 or 4 x M5 screws for 40 mm width
2 or 4 x M4 screws for 60 mm width
2

Casing:
30 mm width with standardized dimensions according to
EN 50047.
40 mm width with standardized dimensions according to
EN 50041.
60 mm width compatible with EN 50047 (Fixing).

Terminal for protective conductor placed near the


cable inlet and marked:
M3.5 (+,) pozidriv 2 screw
(Screw head with captive cable clamp)

Block of 2 contacts:
configuration: 1 N.O. + 1 N.C. or 2 N.O. or 2 N.C.
Positive opening operation
Snap action or slow action
The 2 contacts are electrically separated

Electrical connection:
1 (LS30M), 1 (LS40M) or 3 (LS70M) cable inlets for
Pg 13.5 cable gland
1 (LS31M) or 3 (LS71M) cable inlets for Pg 11 cable gland
1 (LS32M) or 3 (LS72M) cable inlets for ISO 16
cable gland
1 (LS33M), 1 (LS43M) or 3 (LS73M) cable inlets for
ISO 20 cable gland
1 (LS35M), 1 (LS45M) or 3 (LS75M) cable inlets for
1/2 NPT cable gland
Suitable for conduit connection only with use of adaptor
sleeve optionally provided by manufacturer. (on request)

Type

Example:

L1221D

Contact

L S

3 2

L S

Limit Switch .................................................................................LS


Casing width: 30 mm ..................................................................................... 3
1 cable inlet for Pg 13.5 cable gland ....................................................................0
1 cable inlet for Pg 11 cable gland .......................................................................1
1 cable inlet M16 x 1.5 for ISO 16 cable gland ....................................................2
1 cable inlet M20 x 1.5 for ISO 20 cable gland ....................................................3
1 cable inlet for 1/2" NPT cable gland ..................................................................5
Casing width: 40 mm ..................................................................................... 4
1 cable inlet for Pg 13.5 cable gland ....................................................................0
1 cable inlet M20 x 1.5 for ISO 20 cable gland ....................................................3
1 cable inlet for 1/2" NPT cable gland ..................................................................5
Casing width: 60 mm (new casing) ................................................................ 7
3 cable inlets for Pg 13.5 cable gland ..................................................................0
3 cable inlets for Pg 11 cable gland .....................................................................1
3 cable inlets M16 x 1.5 for ISO 16 cable gland ...................................................2
3 cable inlets M20 x 1.5 for ISO 20 cable gland ...................................................3
3 cable inlets for 1/2" NPT cable gland ................................................................5

14
1SBC141157C0202

4 1

Connecting terminals:
(+,) pozidriv 2 screw
(Screw head with captive cable clamp)
Markings conform with IEC 60947-1, IEC 60947-5-1,
EN 50005 and EN 50013 standards
M3.5

B 1 1

Contact types:
11 ........... 1 N.O. + 1 N.C. contacts
20 ........... 2 N.O. contacts
02 ........... 2 N.C. contacts

Snap action:
B ...........Zb Snap (except for 2 N.O. contacts)
Dependent (slow) action:
L ............Slow / Simultaneous
D ...........Zb Non-overlapping late make
C ...........Zb Overlapping early make

Operating heads: (see panorama)


10 ... 98 .........................................................................................................................Codes

M ...................................................................................................................................... Metal casing

LS2..P.. Limit Switches


Double insulation - Plastic Casing IP67
30 mm and 35 mm Width
1SBC5 9296 2F0302

LS20P: 1 cable output left / right .........................


LS21P: 1 cable output bottom .............................
LS25P: 1 cable output left / right .........................
LS26P: 1 cable output bottom .............................

0 .............................................. 5 9
5 .............................................. 6 7
6 .............................................. 6 8
see table below

Ordering Details
Contact blocks
1SBC5 9366 2F0302

LS20P11B11

13

21

14

22

13

21

14

22

Zb
B11

Plastic Casing - IP67


30 mm Width
Plastic Casing - IP67
35 mm Width

1 .............................................. 6 0

see table below

Type

Order code

Weight
kg (1)(2)

state cable output code

state cable output code

Packing
1 piece

LS2
LS2
LS2
LS2

P11B11-P
P11B11-U
P11D11-P
P11D11-U

1SBV01
1SBV01
1SBV01
1SBV01

11R32
11R38
11R33
11R39

0.125
0.125
0.125
0.125

LS2
LS2
LS2
LS2

P12B11-P
P12B11-U
P12D11-P
P12D11-U

1SBV01
1SBV01
1SBV01
1SBV01

12R32
12R38
12R33
12R39

0.130
0.130
0.130
0.130

1SBV01
1SBV01
1SBV01
1SBV01

16R32
16R38
16R33
16R39

0.125
0.125
0.125
0.125

1SBV01
1SBV01
1SBV01
1SBV01

21R32
21R38
21R33
21R39

0.140
0.140
0.140
0.140

Zb
D11

Brass plain plunger (nickel plated)


1
1
-

1SBC5 9322 2F0302

LS21P12B11

1
1

Steel roller plunger (zinc plated)


1
1
1SBC5 9300 2F0302

LS25P16B11

1
1

Brass plain plunger (nickel plated) with dust protection


1
1
-

LS20P21B11

1
1

LS2
LS2
LS2
LS2

P16B11-P
P16B11-U
P16D11-P
P16D11-U

Brass plain plunger (zinc plated) with xing nuts

1SBC5 9301 5F0302

1
1
-

1
1

LS2
LS2
LS2
LS2

P21B11-P
P21B11-U
P21D11-P
P21D11-U

Steel roller plunger (zinc plated) with xing nuts


1
1
-

1SBC5 9303 2F0302

LS20P22B11

1
1

LS2
LS2
LS2
LS2

P22B11-P
P22B11-U
P22D11-P
P22D11-U

1SBV01
1SBV01
1SBV01
1SBV01

22R32
22R38
22R33
22R39

0.145
0.145
0.145
0.145

LS2
LS2
LS2
LS2

P41B11-P
P41B11-U
P41D11-P
P41D11-U

1SBV01
1SBV01
1SBV01
1SBV01

41R32
41R38
41R33
41R39

0.175
0.175
0.175
0.175

14 plastic (polyacetal) roller lever


1
1
-

LS20P41B11

1
1

Adjustable 18 plastic (polyacetal) roller lever

1SBC5 9307 2F0302

1
1
-

1
1

LS2
LS2
LS2
LS2

P51B11-P
P51B11-U
P51D11-P
P51D11-U

1SBV01
1SBV01
1SBV01
1SBV01

51R32
51R38
51R33
51R39

0.190
0.190
0.190
0.190

LS2
LS2

P91B11-P
P91B11-U

1SBV01
1SBV01

91R32
91R38

0.190
0.190

Spring rod
1
1

(1) With LS25 & LS26 add extra 0.005 kg

1SBC5 9338 2F0302

LS20P51B11

LS25P91B11

- (2) With 1 m of cable (add 0.07 kg by extra meter length)

Length cable code

(Other length on request)

Cable
length

Code

Code

1m
2m
5m
10 m

0
0
0
1

0
0
0
1

Note: -P

1
2
5
0

= cable IEC 20/22 II PVC, -U

1
2
5
0

= cable UL 62 PVC maxi. 10 m

15
1SBC141157C0202

LS3..P.. Limit Switches


Double Insulation

- Plastic Casing IP65 - 30 mm Width

SB7721C1

LS30P: 1 cable inlet for Pg 13.5 cable gland ........


LS31P: 1 cable inlet for Pg 11 cable gland ...........
LS32P: 1 cable inlet for ISO 16 cable gland..........
LS33P: 1 cable inlet for ISO 20 cable gland..........
LS35P: 1 cable inlet by 1/2" NPT plastic adaptor ..

0 ............................................. 0 2
1 ............................................. 0 1
2 ............................................. 0 3
3 ............................................. 2 2
5 ............................................. 2 1

Ordering Details
Contact blocks
13

21

14

22

LS30P11B11

13

21

14

22

Zb
B11

Type

Order code

Weight
kg (1)

state cable inlet code

state cable inlet code

Packing
1 piece

Zb
D11

SB7726C1

Steel plain plunger (zinc plated)

LS30P31B11

LS3

P11B11

1SBV01

11R1211

0.070

LS3

P11D11

1SBV01

11R1411

0.070

11 plastic (polyacetal) roller plunger


1

LS3

P13B11

1SBV01

13R1211

0.070

LS3

P13D11

1SBV01

13R1411

0.070

12.5 plastic (polyacetal) roller lever on steel plunger (zinc plated) horizontal action
1

LS3

P31B11

1SBV01

31R1211

0.070

LS3

P31D11

1SBV01

31R1411

0.070

SB7729C1

12.5 plastic (polyacetal) roller lever on steel plunger (zinc plated) vertical action
1

LS3

P32B11

1SBV01

32R1211

0.075

LS3

P32D11

1SBV01

32R1411

0.075

18 plastic (polyacetal) roller lever

LS30P41B11

LS3

P41B11

1SBV01

41R1211

0.090

LS3

P41D11

1SBV01

41R1411

0.090

50 rubber roller lever


1

LS3

P42B11

1SBV01

42R1211

0.120

LS3

P42D11

1SBV01

42R1411

0.120

SB7732C1

Adjustable 18 plastic (polyacetal) roller lever


1

LS3

P51B11

1SBV01

51R1211

0.100

LS3

P51D11

1SBV01

51R1411

0.100

Adjustable 50 rubber roller lever


1

LS3

P52B11

1SBV01

52R1211

0.130

LS3

P52D11

1SBV01

52R1411

0.130

LS30P52B11

Adjustable 3 bre-glass rod lever


1

LS3

P72B11

1SBV01

72R1211

0.100

LS3

P72D11

1SBV01

72R1411

0.100

LS3

P91B11

1SBV01

91R1211

0.080

LS3

P91D11

1SBV01

91R1411

0.080

Spring rod

SB7735C1

(1) For LS35P add 0.007 kg

LS30P91B11

16
1SBC141157C0202

LS4..P.. Limit Switches


Double Insulation

- Plastic Casing IP65 - 40 mm Width

LS40P: 1 cable inlet for Pg 13.5 cable gland ........ 0 ............................................. 0 5


LS43P: 1 cable inlet for ISO 20 cable gland.......... 3 ............................................. 0 7
LS45P: 1 cable inlet for 1/2" NPT cable gland ...... 5 ............................................. 2 4

Ordering Details
SB7738C1

Contact blocks
13

21

14

22

13

21

14

22

Zb
B11

Type

Order code

Weight
kg

state cable inlet code

state cable inlet code

Packing
1 piece

Zb
D11

Steel plain plunger (zinc plated)

LS40P11B11

LS4

P11B11

1SBV01

11R1211

0.140

LS4

P11D11

1SBV01

11R1411

0.140

12 stainless steel roller plunger


1

LS4

P13B11

1SBV01

13R1211

0.145

LS4

P13D11

1SBV01

13R1411

0.145

SB7739C1

22 plastic (polyacetal) roller lever on steel plunger


1

LS4

P31B11

1SBV01

31R1211

0.175

LS4

P31D11

1SBV01

31R1411

0.175

22 plastic (polyacetal) roller lever

LS40P13B11

LS4

P41B11

1SBV01

41R1211

0.185

LS4

P41D11

1SBV01

41R1411

0.185

50 rubber roller lever


1

LS4

P44B11

1SBV01

44R1211

0.205

LS4

P44D11

1SBV01

44R1411

0.205

Adjustable 22 plastic (polyacetal) roller lever


1

LS4

P51B11

1SBV01

51R1211

0.190

LS4

P51D11

1SBV01

51R1411

0.190

SB7747C1

Adjustable 50 rubber roller lever


-

LS4

P54B11

1SBV01

54R1211

0.200

LS4

P54D11

1SBV01

54R1411

0.200

Adjustable 6 plastic (polyacetal) rod lever


1

LS4

P72B11

1SBV01

72R1211

0.185

LS4

P72D11

1SBV01

72R1411

0.185

SB7754C1

LS40P51B11

LS40P72B11

17
1SBC141157C0202

LS7..P.. Limit Switches

1SBC5 8586 5F0302

Double Insulation

LS72P11B11

- Plastic Casing IP65 - 60 mm Width

LS70P: 2 cable inlets for Pg 13.5 cable gland ..... 0 .............................................


LS71P: 2 cable inlets for Pg 11 cable gland ........ 1 .............................................
LS72P: 2 cable inlets for ISO 16 cable gland ....... 2 .............................................
LS73P: 2 cable inlets for ISO 20 cable gland ....... 3 .............................................
LS75P: 1 cable inlet by 1/2" NPT plastic adaptor + 1 cable inlet Pg 11
for additional 1/2" NPT plastic adaptor .................... 5 .............................................

0 9
0 8
1 0
2 8
2 7

Ordering Details
Contact blocks
13

21

14

22

13

21

14

22

Zb
B11

Type

Order code

Weight
kg (1)

state cable inlet code

state cable inlet code

Packing
1 piece

Zb
D11

1SBC5 8589 4F0302

Steel plain plunger (zinc plated)

LS72P31B11

LS7

P11B11

1SBV01

11R1211

0.100

LS7

P11D11

1SBV01

11R1411

0.100

11 plastic (polyacetal) roller plunger


1

LS7

P13B11

1SBV01

13R1211

0.100

LS7

P13D11

1SBV01

13R1411

0.100

12.5 plastic (polyacetal) roller lever on steel plunger (zinc plated)


1

LS7

P31B11

1SBV01

31R1211

0.105

LS7

P31D11

1SBV01

31R1411

0.105

1SBC5 8592 4F0302

18 plastic (polyacetal) roller lever

LS72P41B11

LS7

P41B11

1SBV01

41R1211

0.125

LS7

P41D11

1SBV01

41R1411

0.125

50 rubber roller lever


1

LS7

P42B11

1SBV01

42R1211

0.145

LS7

P42D11

1SBV01

42R1411

0.145

Adjustable 18 plastic (polyacetal) roller lever


1

LS7

P51B11

1SBV01

51R1211

0.135

LS7

P51D11

1SBV01

51R1411

0.135

1SBC5 8600 5F0302

Adjustable 50 rubber roller lever


1

LS7

P52B11

1SBV01

52R1211

0.155

LS7

P52D11

1SBV01

52R1411

0.155

Adjustable 3 bre-glass rod lever


1

LS7

P72B11

1SBV01

72R1211

0.120

LS7

P72D11

1SBV01

72R1411

0.120

LS7

P91B11

1SBV01

91R1211

0.110

LS3

P91D11

1SBV01

91R1411

0.110

Spring rod

LS72P91B11

Pull action with ring


1

LS7

P98B11-A

1SBV01

98R1211

0.145

LS7

P98D11-A

1SBV01

98R1411

0.145

1SBC5 8602 4F0302

(1) For LS75P add 0.007 kg

LS72P98B11-A

18
1SBC141157C0202

LS2..M.. Limit Switches


Metal Casing IP67 - 30 mm and 35 mm Width

1SBC5 9296 2F0302

LS20M: 1 cable output left / right ........................


LS21M: 1 cable output bottom ...........................
LS25M: 1 cable output left / right ........................
LS26M: 1 cable output bottom ...........................

0 .............................................. 5 5
5 .............................................. 6 3
6 .............................................. 6 4
see table below

Ordering Details
Contact blocks
1SBC5 9366 2F0302

LS20M11B11

13

21

14

22

13

21

14

22

Zb
B11

Metal Casing - IP67


30 mm Width
Metal Casing - IP67
35 mm Width

1 .............................................. 5 6

see table below

Type

Order code

Weight
kg (1)(2)

state cable output code

state cable output code

Packing
1 piece

LS2
LS2
LS2
LS2

M11B11-P
M11B11-U
M11D11-P
M11D11-U

1SBV01
1SBV01
1SBV01
1SBV01

11R20
11R26
11R21
11R27

0.175
0.175
0.175
0.175

LS2
LS2
LS2
LS2

M12B11-P
M12B11-U
M12D11-P
M12D11-U

1SBV01
1SBV01
1SBV01
1SBV01

12R20
12R26
12R21
12R27

0.180
0.180
0.180
0.180

1SBV01
1SBV01
1SBV01
1SBV01

16R20
16R26
16R21
16R27

0.175
0.175
0.175
0.175

1SBV01
1SBV01
1SBV01
1SBV01

21R20
21R26
21R21
21R27

0.190
0.190
0.190
0.190

Zb
D11

Brass plain plunger (nickel plated)


1
1
-

1SBC5 9322 2F0302

LS21M12B11

1
1

Steel roller plunger (zinc plated)


1
1
1SBC5 9300 2F0302

LS25M16B11

1
1

Brass plain plunger (nickel plated) with dust protection


1
1
-

LS20M21B11

1
1

LS2
LS2
LS2
LS2

M16B11-P
M16B11-U
M16D11-P
M16D11-U

Brass plain plunger (nickel plated) with xing nuts

1SBC5 9301 5F0302

1
1
-

1
1

LS2
LS2
LS2
LS2

M21B11-P
M21B11-U
M21D11-P
M21D11-U

Steel roller plunger (zinc plated) with xing nuts


1
1
-

1SBC5 9303 2F0302

LS20M22B11

1
1

LS2
LS2
LS2
LS2

M22B11-P
M22B11-U
M22D11-P
M22D11-U

1SBV01
1SBV01
1SBV01
1SBV01

22R20
22R26
22R21
22R27

0.195
0.195
0.195
0.195

LS2
LS2
LS2
LS2

M41B11-P
M41B11-U
M41D11-P
M41D11-U

1SBV01
1SBV01
1SBV01
1SBV01

41R20
41R26
41R21
41R27

0.225
0.225
0.225
0.225

14 plastic (polyacetal) roller lever


1
1
-

LS20M41B11

1
1

Adjustable 18 plastic (polyacetal) roller lever

1SBC5 9307 2F0302

1
1
-

1
1

LS2
LS2
LS2
LS2

M51B11-P
M51B11-U
M51D11-P
M51D11-U

1SBV01
1SBV01
1SBV01
1SBV01

51R20
51R26
51R21
51R27

0.240
0.240
0.240
0.240

LS2
LS2

M91B11-P
M91B11-U

1SBV01
1SBV01

91R20
91R26

0.240
0.240

Spring rod
1
1

(1) For LS25 & LS26 add extra 0.005 kg

1SBC5 9338 2F0302

LS20M51B11

LS25M91B11

- (2) With 1 m of cable (add 0.1 kg by extra meter length)

Length cable code

(Other length on request)

Cable
length

Code

Code

1m
2m
5m
10 m

0
0
0
1

0
0
0
1

Note: -P

1
2
5
0

= cable IEC 20/22 II PVC, -U

1
2
5
0

= cable UL 62 PVC maxi. 10 m

19
1SBC141157C0202

LS3..M.. Limit Switches


Metal Casing IP66 - 30 mm Width

1SBC5 8567 3F0302

LS30M: 1 cable inlet for Pg 13.5 cable gland .......


LS31M: 1 cable inlet for Pg 11 cable gland ..........
LS32M: 1 cable inlet for ISO 16 cable gland .........
LS33M: 1 cable inlet for ISO 20 cable gland .........
LS35M: 1 cable inlet for 1/2" NPT cable gland ........

LS32M11B11

0 ............................................. 1 8
1 ............................................. 1 7
2 ............................................. 1 9
3 ............................................. 3 8
5 ............................................. 3 7

Ordering Details
Contact blocks
13

21

14

22

13

21

14

22

Zb
B11

Type

Order code

Weight
kg

state cable inlet code

state cable inlet code

Packing
1 piece

Zb
D11

1SBC5 8569 3F0302

Steel plain plunger (zinc plated)

LS32M12B11

LS3

M11B11

1SBV01

11R1211

0.180

LS3

M11D11

1SBV01

11R1411

0.180

Steel roller plunger (zinc plated)


1

LS3

M12B11

1SBV01

12R1211

0.185

LS3

M12D11

1SBV01

12R1411

0.185

12.5 plastic (polyacetal) roller lever on steel plunger (zinc plated) horizontal action
1

LS3

M31B11

1SBV01

31R1211

0.175

LS3

M31D11

1SBV01

31R1411

0.175

1SBC5 8572 3F0302

12.5 plastic (polyacetal) roller lever on steel plunger (zinc plated) vertical action
1

LS3

M32B11

1SBV01

32R1211

0.175

LS3

M32D11

1SBV01

32R1411

0.175

22 plastic (polyacetal) roller lever on steel plunger (zinc plated)


1

LS3

M38B11

1SBV01

38R1211

0.180

LS3

M38D11

1SBV01

38R1411

0.180

18 plastic (polyacetal) roller lever

LS32M38B11

LS3

M41B11

1SBV01

41R1211

0.230

LS3

M41D11

1SBV01

41R1411

0.230

50 rubber roller lever


1

LS3

M42B11

1SBV01

42R1211

0.255

LS3

M42D11

1SBV01

42R1411

0.255

1SBC5 8573 3F0302

Adjustable 18 plastic (polyacetal) roller lever

LS32M41B11

LS3

M51B11

1SBV01

51R1211

0.240

LS3

M51D11

1SBV01

51R1411

0.240

Adjustable 50 rubber roller lever


1

LS3

M52B11

1SBV01

52R1211

0.265

LS3

M52D11

1SBV01

52R1411

0.265

LS3

M91B11

1SBV01

91R1211

0.180

LS3

M91D11

1SBV01

91R1411

0.180

1SBC5 8576 3F0302

Spring rod

LS32M51B11

20
1SBC141157C0202

LS4..M.. Limit Switches


Metal Casing IP66 - 40 mm Width
LS40M: 1 cable inlet for Pg 13.5 cable gland ....... 0 ............................................. 1 1
LS43M: 1 cable inlet for ISO 20 cable gland ......... 3 ............................................. 1 6
LS45M: 1 cable inlet for 1/2" NPT cable gland ....... 5 ............................................. 3 1

Ordering Details

SB7758C1

Contact blocks
13

21

14

22

13

21

14

22

Zb
B11

Type

Order code

Weight
kg

state cable inlet code

state cable inlet code

Packing
1 piece

Zb
D11

Stainless steel plain plunger


LS40M11B11

LS4

M11B11

1SBV01

11R1211

0.240

LS4

M11D11

1SBV01

11R1411

0.240

12 stainless steel roller plunger


1

LS4

M13B11

1SBV01

13R1211

0.240

LS4

M13D11

1SBV01

13R1411

0.240

SB7767C1

22 plastic (polyacetal) roller lever on stainless steel plunger


1

LS4

M31B11

1SBV01

31R1211

0.275

LS4

M31D11

1SBV01

31R1411

0.275

22 plastic (polyacetal) roller lever


LS40M41B11

LS4

M41B11

1SBV01

41R1211

0.280

LS4

M41D11

1SBV01

41R1411

0.280

22 stainless steel roller lever


1

LS4

M42B11

1SBV01

42R1211

0.280

LS4

M42D11

1SBV01

42R1411

0.280

Adjustable 22 plastic (polyacetal) roller lever


1

LS4

M51B11

1SBV01

51R1211

0.290

LS4

M51D11

1SBV01

51R1411

0.290

SB7771C1

Adjustable 6 plastic (polyacetal) rod lever


-

LS4

M72B11

1SBV01

72R1211

0.285

LS4

M72D11

1SBV01

72R1411

0.285

LS4

M91B11

1SBV01

91R1211

0.235

LS4

M91D11

1SBV01

91R1411

0.235

Spring rod

SBC779C1

LS40M51B11

LS40M91B11

21
1SBC141157C0202

LS7..M.. Limit Switches


Metal Casing IP66 - 60 mm Width

1SBC5 8603 4F0302

LS70M: 3 cable inlets for Pg 13.5 cable gland .....


LS71M: 3 cable inlets for Pg 11 cable gland ........
LS72M: 3 cable inlets for ISO 16 cable gland ......
LS73M: 3 cable inlets for ISO 20 cable gland ......
LS75M: 3 cable inlets for 1/2" NPT cable gland ......

1 ............................................. 4 1
2 ............................................. 4 3
3 ............................................. 5 2
5 ............................................. 5 1

Ordering Details
Contact blocks
13

21

14

22

13

21

14

22

Zb
LS72M11B11

0 ............................................. 4 2

B11

Type

Order code

Weight
kg

state cable inlet code

state cable inlet code

Packing
1 piece

Zb
D11

1SBC5 8604 4F0302

Steel plain plunger (zinc plated)

LS72M12B11

LS7

M11B11

1SBV01

11R1211

0.270

LS7

M11D11

1SBV01

11R1411

0.270

Steel roller plunger (zinc plated)


1

LS7

M12B11

1SBV01

12R1211

0.280

LS7

M12D11

1SBV01

12R1411

0.280

12.5 plastic (polyacetal) roller lever on steel plunger (zinc plated) horizontal action
1

LS7

M31B11

1SBV01

31R1211

0.265

LS7

M31D11

1SBV01

31R1411

0.265

1SBC5 8607 4F0302

22 plastic (polyacetal) roller lever on steel plunger (zinc plated)

LS72M38B11

LS7

M38B11

1SBV01

38R1211

0.270

LS7

M38D11

1SBV01

38R1411

0.270

18 plastic (polyacetal) roller with bent lever


1

LS7

M45B11

1SBV01

45R1211

0.335

LS7

M45D11

1SBV01

45R1411

0.335

Adjustable 3 stainless steel rod lever


1

LS7

M71B11

1SBV01

71R1211

0.380

LS7

M71D11

1SBV01

71R1411

0.380

LS7

M91B11

1SBV01

91R1211

0.315

LS7

M91D11

1SBV01

91R1411

0.315

1SBC5 8610 4F0302

Spring rod

1SBC5 8620 5F0302

LS72M45B11

LS72M98B11-A

22
1SBC141157C0202

Pull action with ring


1

LS7

M98B11-A

1SBV01

98R1211

0.350

LS7

M98D11-A

1SBV01

98R1411

0.350

Limit Switches Plastic or Metal Casing


Travel and Operation Diagrams

PO
PR

C3

C1

CL

PA

L
L0338D

PP

C2

CP

F1

C4

C
C
L1236D

C: Travel in degrees

C: Travel in millimetres

PO Free position:
position of the switch actuator when no external force is exerted on it.
PA Operating position:
position of the switch actuator, under the effect
of force F1, when the contacts leave their initial
free position.

CP Positive opening travel:


minimum travel of the switch actuator, from the
free position, to ensure positive opening operation of the normally closed contact (N.C.).

CL Max. travel (maximum travel):


distance between the free position PO and the
max. travel position L.

L
Max. travel position:
maximum acceptable travel position of the
switch actuator under the effect of a force F1.

C3 Differential travel (C1-C4) (average


travel):
travel difference of the switch actuator between
the operating position PA and the release position PR.

C1 Pre-travel (average travel):


distance between the free position PO and
the operating position PA.

CL
CP

PP

C1
21-22
13-14
21-22
13-14

C2 Over-travel (average travel):


distance between the operating position PA and
the max. travel position L.

PP Positive opening position:


position of the switch actuator from which
positive opening is ensured.

PR Release position:
position of the switch actuator when the
contacts return to their initial free position.

Diagram for snap action contacts:

Actuation
Release
C4 C3

Diagram for non-overlapping


slow action contacts:
CL
CP

PP

C1-1

Actuation
and release

21-22
13-14

C1-2

C4 Release travel (average travel):


distance between the release position PR and
the free position PO.

Contacts position

21-22

Contact closed

21-22

Contact open

Contacts identification (example)

Note: for slow action contacts, C3 = 0, C1-1 = pre-travel of contact 21-22, C1-2 = pre-travel of contact 13-14.

Examples:
LS32M13B11
(snap action contacts)

Diagram in millimetres/cam travel

LS32M41B11
(snap action contacts)

Diagram in degrees/lever rotation

0 3.0 4.8

7.7

9.6 mm

21-22
13-14
21-22
13-14

0 9

21

50

87

21-22
13-14
21-22
13-14

LS32M11D11
(non-overlapping slow action contacts)

Diagram in millimetres/plunger travel


0

1.9 3.5

5.6 mm

21-22
13-14

2.8

23
1SBC141157C0202

LS20 ... LS26 Prewired Limit Switches


Plastic Casing
Technical Data

IP67 and Metal Casing IP67

General Technical Data


Plastic Casing
Metal Casing
IEC 60947-1, IEC 60947-5-1, EN 60947-1, EN 60947-5-1, UL 508 and CSA C22-2 n 14
UL - CSA (only with UL62-1581 cable)

Standards
Certications - Approvals
Air temperature near the device
during operation
C
for storage
C
Climatic withstand
Mounting positions
Shock withstand (according to IEC 68-2-27 and EN 60068-2-27)
Resistance to vibrations (acc. to IEC 68-2-6 and EN 60068-2-6)
Protection against electrical shocks (acc. to IEC 536)
Degree of protection (according to IEC 529 and EN 60529)
Degree of protection (according to UL 50 and NEMA)
Consistency (measured over 1 million operations)

25 ... + 70
25 ... + 70
40 ... + 70
40 ... + 70
According to IEC 68-2-3 and salty mist according to IEC 68-2-11
All positions are authorized
25g* (1/2 sinusoidal shock for 11 ms) no change in contact position
25g** (10 ... 500 Hz) no change in position of contacts greater than 100 s
Class II
Class I
IP67
Type 1 Enclosure (indoor use)
Type 4 - 4x - 6 Enclosure (Outdoor use)
0.1 mm (upon closing point)

Electrical Data
Rated insulation voltage Ui
according to IEC 60947-1 and EN 60947-1
according to UL 508, CSA C22-2 n 14
Rated impulse withstand voltage Uimp

V
V
kV

400 (degree of pollution 3)


300
4

(according to IEC 60947-1 and EN 60947-1)

Conventional enclosed thermal current Ithe


(according to IEC 60947-5-1 and EN 60947-5-1 ) < 40 C
Short-circuit protection gG type fuses
Rated operational current
Ie / AC-15 acc. to IEC 60947-5-1 24 V - 50/60 Hz
120 V - 50/60 Hz
240 V - 50/60 Hz

A
A
A

5.0
3.0
1.5
B 300
1.1
0.22
0.1
R 300
Contacts with positive opening operation as per IEC 60947-5-1 chapter 3 and EN 60947-5-1
25

acc. to UL 508, CSA C22 n 14

Ie / DC-13 acc. to IEC 60947-5-1

24 V - d.c.
125 V - d.c.
250 V - d.c.

A
A
A

acc. to UL 508, CSA C22 n 14

Positivity
Resistance between contacts

m
mm2 / AWG

4 x 0.75 mm2 / 4 x AWG 18

5 x 0.75 mm2 / 5 x AWG 18

UL 62-1581 (PVC)
IEC 20/22 II (PVC) (no flame propagation)

Black - ext. 7.20 + 0.2


Black - ext. 7.20 + 0.2

Black - ext. 8.20 + 0.2


Grey - ext. 8.20 + 0.2

Terminal marking

According to EN 50013

Mechanical durability
Electrical durability (according to IEC 60947-5-1 appendix C)
max. switching frequency
Cycles/h
load factor

10 Millions of operations
Utilization categories AC-15 and DC-13 (See curves and values below)
3600
0.5

Pre-wired connection
Type of cable

* Shock: 25g for LS20P/M.., ... LS26P/M.. with D11 contact block
5g for LS20P/M.., ... LS26P/M.. with B11 contact block
**Vibrations: except for LS20P/M93 ... LS26P/M93 : 15 g

Electrical durability for AC-15 utilization category


Snap action

Slow action

L1383DG

0.5

24
1SBC141157C0202

3
5
10
Current (A)

0.5
0.3
0.2

L1384D2G

Millions of operating cycles

24

0.2

48

0-

0.3

4-

4
-2

23

0.5

0
23

12

48

13

110

-2

Power breaking for a durability of


5 million operating cycles

Ithe

12

Ithe

3
Millions of operating cycles

Snap action

0.1
0.2 0.3

Electrical durability for DC-13 utilization category

Slow action

0.1
1

10
Current (A)

Voltage

24 V

5.7 W

7.2 W

Voltage

48 V

4.1 W

5.4 W

Voltage 110 V

2.2 W

3.6 W

LS3..., LS4... and LS7... Limit Switches


Plastic Casing
Technical Data

IP65 and Metal Casing IP66

General Technical Data


Plastic Casing
Metal Casing
IEC 60947-1, IEC 60947-5-1, EN 60947-1, EN 60947-5-1, UL 508 and CSA C22-2 n 14
UL - CSA - CCC

Standards
Certications - Approvals
Air temperature near the device
during operation
C
for storage
C
Climatic withstand
Mounting positions
Shock withstand (according to IEC 68-2-27 and EN 60068-2-27) g
Resistance to vibrations (acc. to IEC 68-2-6 and EN 60068-2-6) g
Protection against electrical shocks (acc. to IEC 536)
Degree of protection (according to IEC 529 and EN 60529)
Consistency (measured over 1 million operations)

25 ... + 70
25 ... + 70
30 ... + 80
30 ... + 80
According to IEC 68-2-3 and salty mist according to IEC 68-2-11
All positions are authorized
50g* (1/2 sinusoidal shock for 11 ms) no change in contact position
25g (10 ... 500 Hz) no change in position of contacts greater than 100 s
Class II
Class I
IP65
IP66 **
0.1 mm (upon closing point)
0.1 mm (upon closing point)

Electrical Data
Rated insulation voltage Ui
according to IEC 60947-1 and EN 60947-1
according to UL 508, CSA C22-2 n 14
Rated impulse withstand voltage Uimp

V
V
kV

500 (degree of pollution 3)


600
6

400 (LS3..M.. & LS7..M..), 500 (LS4xM..) - (degree of pollution 3)


300 (LS3..M.. & LS7..M..), 600 (LS4..M..)

(according to IEC 60947-1 and EN 60947-1)

Conventional enclosed thermal current Ithe


(according to IEC 60947-5-1 and EN 60947-5-1 ) < 40 C
Short-circuit protection gG type fuses
Rated operational current
Ie / AC-15 acc. to IEC 60947-5-1 24 V - 50/60 Hz
130 V - 50/60 Hz
230 V - 50/60 Hz
240 V - 50/60 Hz
400 V - 50/60 Hz

10

10

A
A
A
A
A

10
5.5
3.1
3
1.8
A 600
A 300 (LS3..M.. & LS7..M..), A 600 (LS4..M..)
2.8
0.6
0.27
Q 600
Q 300 (LS3..M.. & LS7..M..), Q 600 (LS4..M..)
Contacts with positive opening operation as per IEC 60947-5-1 chapter 3 and EN 60947-5-1
25

acc. to UL 508, CSA C22 n 14

Ie / DC-13 acc. to IEC 60947-5-1

24 V - d.c.
110 V - d.c.
250 V - d.c.

A
A
A

acc. to UL 508, CSA C22 n 14

Positivity
Resistance between contacts
Mechanical durability

m
Millions
of
operations
Millions
of
operations

15
10
>5
15
10
>5

Electrical durability (according to IEC 60947-5-1 appendix C)


max. switching frequency
Cycles/h
load factor
Connecting data of contact blocks
Connecting terminals
Connecting capacity
1 or 2 x mm2 / AWG
Terminal marking

}
}

3x
LS

P
7x

LS 4x P

{
{

10...12 ; 30...38
13 ; 41...46 ; 51...55 ; 61...78
14 ; 91...92 ; 98

15
10
>5

11 ; 12 ; 31...33
13 ; 41...44 ; 51...55 ; 61...74
14 ; 19 ; 34...36 ; 91...93

30
25
10

}
}

3x
LS

M
7x

LS 4x M

{
{

11...12 ; 31...38
13 ; 41...46 ; 51...55 ; 61...78
14 ; 91...92 ; 98
11...13 ; 21...23 ; 31...33
41...44 ; 51...55 ; 61...74
91...93

Utilization categories AC-15 and DC-13 (see curves and values below)
3600
0.5
M3.5 (+,) pozidriv 2 screw with cable clamp
0.5 mm2 / AWG 20 to 2.5 mm2 / AWG 14
According to EN 50013

for LS3..M42, M52 and M55 - LS3..P42, P52 and P55 - LS7..M42, M52 and M55 - LS7..P42, P52 and P55: 25g
* Except
** Except for LS3..M52, M55, M73, M74 and M92 - LS7..M52, M55, M73, M74 and M92 - LS4..M54, M72, M92 and M93 : the degree of protection is IP65.

Electrical durability for AC-15 utilization category

0.5
0.3

0.1
0.2 0.3

L0351DG

0.2

0.5

3
5
10
Current (A)

0.5

Voltage

24 V

9.5 W

12 W

Voltage

48 V

6.8 W

9W

Voltage 110 V

3.6 W

6W

0.3
0.2
L0350DG

13

Slow action

Power breaking for a durability of


5 million operating cycles

23

48

24

40

-2

0-

Millions of operating cycles

24

48

Snap action

12 -

130

23

Electrical durability for DC-13 utilization category

Slow action

12

Millions of operating cycles

Snap action

0.1
1

10
Current (A)

25
1SBC141157C0202

LS2..P.. and LS2..M.. Limit Switches


Plastic Casing
Prewired
Movement to be detected:

and Metal Casing - IP67 - 30 mm Width

On end

30 Cam Trans.

On end

For Plastic Casing:


Cable: 4 x 0.75 mm2 / 4 x AWG 18
Length: 1 m
(Other lengths see ordering details)

For Metal Casing:


Cable: 5 x 0.75 mm2 / 5 x AWG 18
Length: 1 m
(Other lengths see ordering details)

Actuator

Metal plunger

Metal Roller plunger

(with dust protection cup)

Metal plunger

Metal plunger
with xing nuts

0.5 m/s
15 N
30 N

0.5 m/s
15 N
30 N

(N.C. contact with positive opening operation)

Maximum actuation speed


Min. force / torque: - actuation
- positive opening operation

0.5 m/s
15 N
30 N

0.1 m/s
10 N
30 N

Additional Technical Data


Cable output left / right code ................................................ 0
Cable output bottom code.................................................... 1
Plastic casing ............................................................................. P
Metal casing............................................................................... M
IEC 20/22 II PVC cable code ...................................................................... P
UL 62 PVC cable code................................................................................ U
Type to be completed with the above codes

Snap action contacts


13 BN

22 BK

LS2

Type

LS2

5.0 mm

12B11-

0 1.7 3.3

6.9

01
8.7 mm

21-22
13-14
21-22
13-14

11D11-

01

LS2

16B11-

0 1.0 1.9

4.0

01
5.0 mm

21-22
13-14
21-22
13-14

LS2

12D11-

01

LS2

LS2

21B11-

0 1.0 1.9

4.0

01
5.0 mm

21-22
13-14
21-22
13-14

16D11-

01

LS2

21D11-

01

21 BK

Zb
14 BU

4.0

01

21-22
13-14
21-22
13-14

Operation
diagram

Non-overlapping
Slow action contacts
13 BN

11B11-

0 1.0 1.9

Zb
14 BU

LS2

Type

21 BK

Operation
diagram

22 BK

1.9 3.4

Weight (1) (packing per unit)

kg

5.0 mm

3.3 5.9

8.7 mm

21-22
13-14

21-22
13-14

1.9 3.4

5.0 mm

21-22
13-14

3.2

5.5

0.125

0.130

1.9 3.4

5.0 mm

21-22
13-14

3.2

3.2

0.125

0.140

(1) add 0.050 kg with metal casing.

Closed contact /

Open contact

Dimensions (mm)
30

Tightening torque of nuts : 5 N.m


Distance between nuts : 9 mm
Nuts thickness : 3 mm

O 4.3

16

1SBC141157C0202

34

25

L1304D

74
L1406D

29.5
L1407D

69.5

20.5
L1298D

70

30
L1297D

L1296D

60

L1295D

20

11
L1316D

49

40

26

21

M12x1

7
12

8
3.5

12

8
12

20

O 4.3

30

L1303D

31.5

L1330D

49
L1329D

4.5

O 8.2

40

49

20

LS2..P.. and LS2..M.. Limit Switches


Plastic Casing
Prewired
Movement to be detected:

and Metal Casing - IP67 - 30 mm Width

30 Cam Translation Movement

Multidirectional

For Plastic Casing:


Cable: 4 x 0.75 mm2 / 4 x AWG 18
Length: 1 m
(Other lengths see ordering details)

For Metal Casing:


Cable: 5 x 0.75 mm2 / 5 x AWG 18
Length: 1 m
(Other lengths see ordering details)

Actuator

Metal Roller plunger


with xing nuts

14 plastic roller lever

Adjustable 18
plastic roller lever

0.1 m/s
10 N
30 N

1.5 m/s
0.08 N.m
0.28 N.m

1.5 m/s
0.08 N.m
0.28 N.m

Spring rod

1.0 m/s
0.10 N.m

(N.C. contact with positive opening operation)

Maximum actuation speed


Min. force / torque: - actuation
- positive opening operation

Additional Technical Data


Cable output left / right code ................................................ 0
Cable output bottom code.................................................... 1
Plastic casing ............................................................................. P
Metal casing............................................................................... M
IEC 20/22 II PVC cable code ...................................................................... P
UL 62 PVC cable code................................................................................ U
Type to be completed with the above codes

Snap action contacts


13 BN

22 BK

21 BK

14 BU

22 BK

8.7 mm

22D113.3 5.9

01

41B11-

0 14 26

kg

58

LS2

74

41D11-

51B11-

0 14 26

27 49

01

58

01

LS2

27 49

01

0 5 14

74

51D11-

91B11-

21-22
13-14
21-22
13-14

01

74

21-22
13-14

45

0.145

LS2

74

21-22
13-14

5.5

Weight (1) (packing per unit)

01

21-22
13-14
21-22
13-14

LS2

8.7 mm

21-22
13-14

Operation
diagram

LS2
21-22
13-14
21-22
13-14

LS2

Type

Zb

6.9

01

21-22
13-14
21-22
13-14

Operation
diagram

Non-overlapping
Slow action contacts
13 BN

22B11-

0 1.7 3.3

Zb
14 BU

LS2

Type

21 BK

45

0.175

0.190

0.190

(1) add 0.050 kg with metal casing.

Closed contact /

Open contact

Dimensions (mm)
30

Tightening torque of nuts : 5 N.m


Distance between nuts : 9 mm
Nuts thickness : 3 mm

O 4.3

16

6.5
5.5

19...91

L1324D

L1323D

36.1
38.9

L1314D

18

88...158

66.5

L1313D

48...118
L1310D

18

27

52

44.8

L1306D

29.5

181.5

34.4

3.5

84.8
L1316D

L1305D

40

49

35.8

O 4.3

10.4

20

92
66.5

30

30
O 18

4.5
24

O 14

141.5

30
M12x1

L1309D

31.5

L1330D

49
L1329D

4.5

O 8.2

40

49

20

27
1SBC141157C0202

LS2..P.. and LS2..M.. Limit Switches


Plastic Casing
Prewired
Movement to be detected:

and Metal Casing - IP67 - 35 mm Width

On end

30 Cam Trans.

On end

For Plastic Casing:


Cable: 4 x 0.75 mm2 / 4 x AWG 18
Length: 1 m
(Other lengths see ordering details)

For Metal Casing:


Cable: 5 x 0.75 mm2 / 5 x AWG 18
Length: 1 m
(Other lengths see ordering details)

Actuator

Metal plunger

Metal Roller plunger

(with dust protection cup)

Metal plunger

Metal plunger
with xing nuts

0.5 m/s
15 N
30 N

0.5 m/s
15 N
30 N

(N.C. contact with positive opening operation)

Maximum actuation speed


Min. force / torque: - actuation
- positive opening operation

0.5 m/s
15 N
30 N

0.1 m/s
10 N
30 N

Additional Technical Data


Cable output left / right code ................................................ 5
Cable output bottom code.................................................... 6
Plastic casing ............................................................................. P
Metal casing............................................................................... M
IEC 20/22 II PVC cable code ...................................................................... P
UL 62 PVC cable code................................................................................ U
Type to be completed with the above codes

Snap action contacts


13 BN

21 BK

14 BU

22 BK

4.0

01

LS2

Type

LS2

5.0 mm

21-22
13-14
21-22
13-14

Operation
diagram

Non-overlapping
Slow action contacts

12B11-

0 1.7 3.3

6.9

01
8.7 mm

21-22
13-14
21-22
13-14

11D11-

01

LS2

LS2

16B11-

0 1.0 1.9

4.0

01
5.0 mm

21-22
13-14
21-22
13-14

12D11-

01

LS2

LS2

21B11-

0 1.0 1.9

4.0

01
5.0 mm

21-22
13-14
21-22
13-14

16D11-

01

LS2

21D11-

01

21 BK

Zb
14 BU

11B11-

0 1.0 1.9

Zb

13 BN

LS2

Type

Operation
diagram

22 BK

1.9 3.4

5.0 mm

21-22
13-14

Weight (1) (packing per unit)

kg

3.3 5.9

8.7 mm

1.9 3.4

5.0 mm

21-22
13-14

21-22
13-14

3.2

5.5

0.125

0.130

1.9 3.4

5.0 mm

21-22
13-14

3.2

3.2

0.125

0.140

(1) add 0.050 kg with metal casing.

Closed contact /

Open contact

Dimensions (mm)
35
30
O 4.3

16

Tightening torque of nuts : 5 N.m


Distance between nuts : 9 mm
Nuts thickness : 3 mm

L1372D

49

1SBC141157C0202

25

34

L1343D

74
L1342D

L1405D

L1336D

69.5

29.5

20.5
70

30

21
L1335D

60

11

L1334D

28

L1368D

49

40
O 8.2

M12x1
8

7
12

8
3.5

12

8
12
20

25

O 4.3

30

L1404D

35

L1337D

L1371D

O 8.2

4.5

40

49

25

LS2..P.. and LS2..M.. Limit Switches


Plastic Casing
Prewired
Movement to be detected:

and Metal Casing - IP67 - 35 mm Width

30 Cam Translation

Multidirectional

For Plastic Casing:


Cable: 4 x 0.75 mm2 / 4 x AWG 18
Length: 1 m
(Other lengths see ordering details)

For Metal Casing:


Cable: 5 x 0.75 mm2 / 5 x AWG 18
Length: 1 m
(Other lengths see ordering details)

Actuator

Metal Roller plunger


with xing nuts

14 plastic roller lever

Adjustable 18
plastic roller lever

0.1 m/s
10 N
30 N

1.5 m/s
0.08 N.m
0.28 N.m

1.5 m/s
0.08 N.m
0.28 N.m

Spring rod
1.0 m/s
0.10 N.m
-

(N.C. contact with positive opening operation)

Maximum actuation speed


Min. force / torque: - actuation
- positive opening operation

Additional Technical Data


Cable output left / right code ................................................ 5
Cable output bottom code.................................................... 6
Plastic casing ............................................................................. P
Metal casing............................................................................... M
IEC 20/22 II PVC cable code ...................................................................... P
UL 62 PVC cable code................................................................................ U
Type to be completed with the above codes

Snap action contacts


13 BN

21 BK

14 BU

22 BK

21 BK

22 BK

8.7 mm

22D113.3 5.9

01

Weight (1) (packing per unit)

kg

41B11-

0 14 26

58

01

LS2

74

51B11-

0 14 26

58

01

LS2

41D1127 49

01

LS2

74

21-22
13-14

51D1127 49

91B11-

01

0 5 14

74

21-22
13-14
21-22
13-14

21-22
13-14
21-22
13-14

LS2

8.7 mm

21-22
13-14

Operation
diagram

LS2
21-22
13-14
21-22
13-14

LS2

Type

Zb

6.9

01

21-22
13-14
21-22
13-14

Operation
diagram

Non-overlapping
Slow action contacts

14 BU

22B11-

0 1.7 3.3

Zb

13 BN

LS2

Type

01

74

21-22
13-14

5.5

45

45

0.200

0.200

0.230

0.235

(1) add 0.050 kg with metal casing.

Closed contact /

Open contact

Dimensions (mm)
35
30
O 4.3

16

Tightening torque of nuts : 5 N.m


Distance between nuts : 9 mm
Nuts thickness : 3 mm

L1368D

141.5

L1363D

L1362D

38.9

L1353D

L1349D

29.5

36.1
O 8.2

181.5

19...91

18

27
92
66.5

18
L1348D

L1345D

84.8
L1344D

9
40

49

52

44.8

35.8

O 4.3

30
25

5.5

24

66.5

8
3.5

10.4

L1352D

M12x1

35

34.4
6.5

30
O 18

4.5

30
O 14

48...118

L1372D

49
L1371D

O 8.2

4.5

40

49

25

29
1SBC141157C0202

LS3..P.. Limit Switches


Double Insulation - Plastic Casing IP65 - 30 mm Width
1 Cable Inlet for Cable Gland
Movement to be detected:

On end

Actuator

30 Cam Translat.

Metal plunger

11 plastic
roller plunger

Conformity /
(N.C. contact with positive opening operation) EN 50047 (B shape)
Maximum actuation speed
0.5 m/s
Min. force / torque: - actuation
15 N
- positive opening operation
45 N

30 Unidirectional Cam Translation

12.5 plastic roller lever 12.5 plastic roller lever


on steel plunger
on steel plunger

EN 50047 (C shape)
0.3 m/s
12 N
41 N

EN 50047 (E shape)
1 m/s
7N
24 N

1 m/s
7N
24 N

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT (by plastic adaptor)

Snap action contacts

LS3

Type

P11B11

LS3

P13B11

LS3

P31B11

LS3

P32B11

21

13

0 1.7 2.7

Zb
22

14

Non-overlapping
Slow action contacts

Zb
Weight (packing per unit)

0 3.0 4.8

P11D11

7.7

9.6 mm

1.9 3.5

5.6 mm

14.5 21.0 mm

0 4.9 9.0

3.4 6.3

LS3

9.6 mm

14.5

21.0 mm

21-22
13-14
21-22
13-14

P13D11

21-22
13-14

kg

0 4.9 9.0
21-22
13-14
21-22
13-14

LS3

21-22
13-14

Operation
diagram

22

14

5.6 mm

21-22
13-14
21-22
13-14

LS3

Type

21

13

4.3

21-22
13-14
21-22
13-14

Operation
diagram

P31D11

6.0 10.5

LS3

21.0 mm

21-22
13-14

P32D11

6.0 10.5

21.0 mm

21-22
13-14

8.6

2.8

5.1

8.6

0.070

0.070

0.070

0.075

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

24.5

22

12.5

20

30
1SBC141157C0202

O 12.5

L0097D

20
21

92

39

30
92

O12.5
L0096D

L0091D

84

31
19.5

31
L0090D

12.5
5.2

29

L0099D

12.5
5.2

30

19.5
39

12.5
3.5

O 11

73

L0089D

30

L0088D

15

L1289DG

L0086D

30.3

30

12.5

L0098D

O8

20

53

cable
inlet

20

20

O4

LS3..P.. Limit Switches


Double Insulation - Plastic Casing IP65 - 30 mm Width
1 Cable Inlet for Cable Gland
30 Cam Translation Movement

18 plastic
roller lever

Fully Direction Trans.

50 rubber
roller lever

EN 50047 (A shape)
1.5 m/s
0.1 N.m
0.32 N.m

Adjustable 18
plastic roller lever

Adjustable 50
rubber roller lever

Adjustable 3
bre-glass rod lever

1.5 m/s
0.1 N.m
0.32 N.m

Multidirectional

Spring rod
lever

1.5 m/s
0.1 N.m
0.32 N.m

1.5 m/s
0.1 N.m
0.32 N.m

1.5 m/s
0.1 N.m
0.32 N.m

1 m/s
0.12 N.m

LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT (by plastic adaptor)

0 17 31

47

LS3

74

P42B11

0 17 31

21-22
13-14
21-22
13-14

47

LS3

74

0 17 31

21-22
13-14
21-22
13-14

LS3
0

P41D11

21 37

74

47

LS3

74

P42D11

21 37

74

P51D11

74

21 37

74

P72B11

0 17 31

47

LS3

74

P52D11

21 37

74

P72D11

21 37

LS3

74

21-22
13-14

30

30

0.120

0.100

0.130

0.100

0.080

135

188

O 6.3

170

Maxi 230.5

17.5
Maxi 177.5

O6

125.5 ... 184

17.5
72.5...131
42

41

L0111D

L0110D

42
L0106D

L0105D

L0103D

L0102D

L0101D

O 1.2

36

L0107D

36

Open contact

5.5

98.5...170.5

17.5
45.5...117.5
122

17.5

69

17.5
53

5.5

106

O 50

O 18

36
L0100D

Closed contact /

L0104D

O 18

36

52
44.5
32.5

45.5
41
34

51
43.5

14
21

30

O 50

P91D11

21-22
13-14

30

Special heads, accessories and special contact arrangement or particular function: please consult us.

45
40
15

36

21-22
13-14
21-22
13-14

LS3

21-22
13-14

P91B11

0 12 23

21-22
13-14
21-22
13-14

LS3

21-22
13-14

0.090

47

LS3

21-22
13-14
21-22
13-14

LS3

21-22
13-14

30

P52B11

0 17 31

21-22
13-14
21-22
13-14

LS3

21-22
13-14

P51B11

L0113D

P41B11

L0112D

LS3

31
1SBC141157C0202

LS4..P.. Limit Switches


Double Insulation - Plastic Casing IP65 - 40 mm Width
1 Cable Inlet for Cable Gland
Movement to be detected:

On end

Actuator

30 Cam Translat.

Metal plunger

12 stainless steel
roller plunger

Conformity /
(N.C. contact with positive opening operation) EN 50041 (B shape)
Maximum actuation speed
0.5 m/s
Min. force / torque: - actuation
14 N
- positive opening operation
45 N

Unidirectional

30 Cam Translat.

Polyamide roller lever


on steel plunger

EN 50041 (C shape)
0.5 m/s
14 N
40 N

22 plastic
roller lever

EN 50041 (A shape)
1.5 m/s
0.15 N.m
0.30 N.m

1 m/s
8N
40 N

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

Snap action contacts

LS4

Type

P11B11

LS4

P13B11

LS4

P31B11

LS4

P41B11

21

13

0 1.0 2.2

Zb
22

14

Non-overlapping
Slow action contacts

Zb
Weight (packing per unit)

0 2.4 4.6

P11D11

7.5

10.5 mm

1.3 2.9

5.9 mm

11.3

0 19 31

17.0 mm

3.1 6.0

LS4

10.5 mm

47

90

21-22
13-14
21-22
13-14

P13D11

21-22
13-14

kg

0 3.8 6.8
21-22
13-14
21-22
13-14

LS4

21-22
13-14

Operation
diagram

22

14

5.9 mm

21-22
13-14
21-22
13-14

LS4

Type

21

13

3.8

21-22
13-14
21-22
13-14

Operation
diagram

P31D11

4.9 9.4

LS4

17.0 mm

21-22
13-14

P41D11

21 37

90

21-22
13-14

2.1

4.4

6.3

30

0.140

0.145

0.175

0.185

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

15.5
59
53.7
38.2

1SBC141157C0202

22

130

63

27

L0017D

L0016D

52
L0063D

L0015D

121

117
L0014D

L0011D

104

32

L0010D

40.5

L1290DG

L0008D

17
30.5

O 22

48.5
31.5

50

44

O 10

cable
inlet

O 5.4

30
41

15.5

O 22

O 12

20

30

30

L0062D

15.5

37

74

60

O 10

20

15.5

54

6.4

7.4

5.4

LS4..P.. Limit Switches


Double Insulation - Plastic Casing IP65 - 40 mm Width
1 Cable Inlet for Cable Gland
Movement to be detected:

30 Cam Translation Movement

Actuator

50 rubber roller
lever

Conformity /
(N.C. contact with positive opening operation)
Maximum actuation speed
Min. force / torque: - actuation
- positive opening operation

Fully Direction Trans.

Adjustable 22
plastic roller lever

Adjustable 50
rubber roller lever

Adjustable 6
plastic rod lever

1.5 m/s
0.15 N.m
0.30 N.m

1.5 m/s
0.15 N.m
0.30 N.m

EN 50041 (D shape)
1.5 m/s
0.15 N.m
0.30 N.m

1.5 m/s
0.15 N.m
0.30 N.m

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

Snap action contacts

LS4

Type

P44B11

LS4

P51B11

LS4

P54B11

LS4

P72B11

21

13

0 19 31

Zb
22

14

Non-overlapping
Slow action contacts

Zb

0 19 31

P44D11

Weight (packing per unit)

47

90

0 19 31

21 37

90

90

0 19 31

21 37

LS4

90

47

90

21-22
13-14
21-22
13-14

P51D11

21-22
13-14

kg

47

21-22
13-14
21-22
13-14

LS4

21-22
13-14

Operation
diagram

22

14

90

21-22
13-14
21-22
13-14

LS4

Type

21

13

47

21-22
13-14
21-22
13-14

Operation
diagram

P54D11

21 37

LS4

90

21-22
13-14

P72D11

21 37

90

21-22
13-14

30

30

30

0.205

0.190

0.200

30

0.185

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

50.5

22

200
L0039D

L0038D

61.5

L0031D

L0030D

61.5

L0025D

L0024D

61.5
L0023D

40.5

L0022D

17
30.5

L1290DF

L0008D

52
30
41

277 Maxi

82 ... 138

210 Maxi

O6

149 ... 205

22

22

144

entre
de cble

O 5.4

50

135 ... 191

O 22

68 ... 124

O 50

77

74

60

6.4

7.4

64.5
57
9

65
57.5
9
43.5

22

60
55
6
46

15.5

5.4

33
1SBC141157C0202

LS7..P.. Limit Switches


Double Insulation - Plastic Casing IP65 - 60 mm Width
2 Cable Inlets for Cable Gland
Movement to be detected:

On end

Actuator

30 Cam Translat.

Metal plunger

Conformity /
(N.C. contact with positive opening operation)
Maximum actuation speed
Min. force / torque: - actuation
- positive opening operation

11 plastic
roller plunger

Unidirectional

30 Cam Translat.

12.5 plastic roller lever


on steel plunger

0.5 m/s
15 N
45 N

18 plastic
roller lever

0.3 m/s
12 N
41 N

1 m/s
7N
24 N

1.5 m/s
0.1 N.m
0.32 N.m

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT

Snap action contacts

LS7

Type

P11B11

LS7

P13B11

LS7

P31B11

LS7

P41B11

21

13

0 1.7 2.7

Zb
22

14

Non-overlapping
Slow action contacts

Zb
Weight (packing per unit)

kg

0 3.0 4.8

P11D11

7.7

9.6 mm

1.9 3.5

5.6 mm

0 4.9 9.0

14.5 21.0 mm

0 17 31

21-22
13-14
21-22
13-14

LS7

21-22
13-14

Operation
diagram

22

14

5.6 mm

21-22
13-14
21-22
13-14

LS7

Type

21

13

4.3

21-22
13-14
21-22
13-14

Operation
diagram

P13D11

3.4 6.3

LS7

9.6 mm

21-22
13-14

47

74

21-22
13-14
21-22
13-14

P31D11

6.0 10.5

LS7

21.0 mm

21-22
13-14

P41D11

21 37

74

21-22
13-14

30

2.8

5.1

8.6

0.100

0.100

0.105

0.125

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

12.5
4

O4

45
40

cable inlet
O 18

34
1SBC141157C0202

17.5
99
L0951D

L0946D

85
L0945D

L0942D

L0940D

66

53

20

30

15
5.5

31

39

3.5

O 12.5

O 11

77

30

31

25

20
33

L0939D

14

L1291DG

57

L1015D

50

12.5

O8

42

12.5

12.5

L0941D

40

20

46

22

36
L0952D

20

LS7..P.. Limit Switches


Double Insulation - Plastic Casing IP65 - 60 mm Width
2 Cable Inlets for Cable Gland
30 Cam Translation Movement

50 rubber
roller lever

Adjustable 18
plastic roller lever

Adjustable 50
rubber roller lever

1.5 m/s
0.1 N.m
0.32 N.m

Fully Direction Trans.

Multidirectional

Adjustable 3
bre-glass rod lever

Spring rod
lever

1.5 m/s
0.1 N.m
0.32 N.m

Pull action
with ring

1.5 m/s
0.1 N.m
0.32 N.m

Pull action

1.5 m/s
0.1 N.m
0.32 N.m

1 m/s
0.12 N.m

0.5 m/s
30 N

LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT

LS7

P42B11

0 17 31

47

LS7

74

P51B11

0 17 31

21-22
13-14
21-22
13-14

47

LS7

74

0 17 31

21-22
13-14
21-22
13-14

LS7
0

P42D11

21 37

74

47

LS7

74

P51D11

21 37

74

P52D11

74

21 37

74

P91B11

0 12 23

LS7

36

P72D11

21 37

74

5.6 mm

21-22
13-14
21-22
13-14

LS7
0

21-22
13-14

P98B11-A

0 0.9 2.0

21-22
13-14
21-22
13-14

LS7

21-22
13-14

0.145

47

LS7

21-22
13-14
21-22
13-14

LS7

21-22
13-14

30

P72B11

0 17 31

21-22
13-14
21-22
13-14

LS7

21-22
13-14

P52B11

P91D11

14

LS73

36

21-22
13-14

P98D11-A

1.0

5.6 mm

21-22
13-14

1.9

30

30

30

21

0.135

0.155

0.120

0.110

0.145

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Tearing withstand of:


- operating head 200 daN
- ring: 40 daN

12.5

12.5

135

120

74

181

17.5

O 6.3

170

Max. 223.5

L0972D

L0971D

L0968D

L0967D

42
L0966D

L0959D

O 27
3

42
L0960D

17.5

122.5...179.5

77...133.5
42
L0958D

17.5
L0957D

91.5...163.5

45.5...117.5
L0954D

36

O 1.2

L0965D

O 50
5.5

17.5
112.5
L0953D

69

O 50

45.5
41
34

O 18

36

5.5

Max. 177.5

51
43.5

51
44.5
32.5

35
1SBC141157C0202

LS3..M.. Limit Switches


Metal Casing IP66 - 30 mm Width
1 Cable Inlet for Cable Gland
Movement to be detected:

On end

Actuator

Metal plunger

Conformity /
(N.C. contact with positive opening operation) EN 50047 (B shape)
Maximum actuation speed
0.5 m/s
Min. force / torque: - actuation
15 N
- positive opening operation
45 N

30 Cam Translat.

30 Unidirectional Cam Translation

Metal roller plunger

12.5 plastic roller lever


on steel plunger

12.5 plastic roller lever


on steel plunger

EN 50047 (E shape)
1 m/s
7N
24 N

EN 50047 (C shape)
0.3 m/s
12 N
41 N

1 m/s
7N
24 N

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT

Snap action contacts


13

22

M12B11

LS3

Weight (packing per unit)

kg

0 3.0 4.8

5.6 mm

M11D11

M31B11

LS3

7.7

9.6 mm

1.9 3.5

5.6 mm

0 4.9 9.0

14.5 21.0 mm

21-22
13-14
21-22
13-14

LS3

21-22
13-14

Operation
diagram

22

4.3

21-22
13-14
21-22
13-14

LS3

Type

21

Zb
14

LS3

21-22
13-14
21-22
13-14

Operation
diagram

Non-overlapping
Slow action contacts
13

M11B11

0 1.7 2.7

Zb
14

LS3

Type

M32B11

21

M12D11

3.4 6.3

LS3

9.6 mm

21-22
13-14

0 4.9 9.0

14.5

21.0 mm

21-22
13-14
21-22
13-14

M31D11

6.0 10.5

LS3

21.0 mm

21-22
13-14

M32D11

6.0 10.5

21.0 mm

21-22
13-14

8.6

2.8

5.1

8.6

0.180

0.185

0.175

0.175

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

12.5
4

O4

36
1SBC141157C0202

12.5

12.5

20

L0909D

L0908D

21

L0910D

94

20
94
L0907D

L0906D

86
L0905D

L0902D

75

29
O12.5

5
39

39

30

31

3.5

O 12.5

12.5
O 11
31

20
32.5

L0901D

14.5

L1292DG

L1009D

30.3

25

O8
cable
inlet

20

12.5

30

30

55

20
22

LS3..M.. Limit Switches


Metal Casing IP66 - 30 mm Width
1 Cable Inlet for Cable Gland
Unidirectional

30 Cam Translation Movement

22 plastic roller lever


on steel plunger

18 plastic roller
lever

50 rubber roller
lever

EN 50047 (A shape)
1.5 m/s
0.1 N.m
0.32 N.m

1 m/s
7N
24 N

Multidirectional

Adjustable 18
plastic roller lever

Adjustable 50
rubber roller lever

Spring rod
lever

1.5 m/s
0.1 N.m
0.32 N.m

1.5 m/s
0.1 N.m
0.32 N.m

1.5 m/s
0.1 N.m
0.32 N.m

1 m/s
0.12 N.m

LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT

LS3

M38B11

0 8.8 15.0

23.2

LS3

32.0 mm

21-22
13-14
21-22
13-14

M41B11

0 17 31

47

LS3

74

0 17 31

21-22
13-14
21-22
13-14

LS3
0

M38D11

10.6 18.5

32.0 mm

47

LS3

74

M41D11

21 37

74

47

LS3

74

M42D11

21 37

74

47

LS3

74

M51D11

21 37

74

36

21-22
13-14
21-22
13-14

LS3
0

21-22
13-14

M91B11

0 12 23

21-22
13-14
21-22
13-14

LS3

21-22
13-14

M52B11

0 17 31

21-22
13-14
21-22
13-14

LS3

21-22
13-14

M51B11

0 17 31

21-22
13-14
21-22
13-14

LS3

21-22
13-14

M42B11

M52D11

21 37

LS3

74

21-22
13-14

M91D11

14

36

21-22
13-14

21

15.1

30

30

30

30

0.180

0.230

0.255

0.240

0.265

0.180

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

12.5

O 50

9
O 1.2

5.5

L0932D

190

135
L0922D

17.5
L0921D

O 6.3

127.5...186

72.5...131
42
L0920D

17.5
L0919D

36

100.5....172.5

17.5

45.5...117.5

L0931D

45.5
41
34

O 18

L0916D

L0913D

L0912D

108

69

53
106
L0911D

36
L0914D

124

O 18

51
O 22

12.5

O 50

15
5.5

17.5

17...23 29...35

51
43.5

L0915D

45
40

52
44.5
32.5

37
1SBC141157C0202

LS4..M.. Limit Switches


Metal Casing IP66 - 40 mm Width
1 Cable Inlet for Cable Gland
Movement to be detected:

On end

Actuator

30 Cam Translat.

Stainless steel
plunger

12 stainless steel
roller plunger

Conformity /
(N.C. contact with positive opening operation) EN 50041 (B shape)
Maximum actuation speed
0.5 m/s
Min. force / torque: - actuation
30 N
- positive opening operation
45 N

Unidirectional

30 Cam Translat.

22 plastic roller lever


on stainless steel plunger

EN 50041 (C shape)
0.5 m/s
22 N
40 N

22 plastic
roller lever
EN 50041 (A shape)
1.5 m/s
0.15 N.m
0.30 N.m

1.5 m/s
12 N
40 N

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

Snap action contacts

LS4

Type

M11B11

LS4

M13B11

LS4

M31B11

LS4

M41B11

21

13

0 1.8 3.0

Zb
22

14

Non-overlapping
Slow action contacts

Zb
Weight (packing per unit)

0 3.1 5.3

M11D11

8.2 10.5 mm

2.1 3.7

6.0 mm

10.8

0 20 33

15.5 mm

4.0 6.9

LS4

10.5 mm

49

78

21-22
13-14
21-22
13-14

M13D11

21-22
13-14

kg

0 3.1 6.3
21-22
13-14
21-22
13-14

LS4

21-22
13-14

Operation
diagram

22

14

6.0 mm

21-22
13-14
21-22
13-14

LS4

Type

21

13

4.6

21-22
13-14
21-22
13-14

Operation
diagram

M31D11

4.5 9.0

LS4

15.5 mm

21-22
13-14

M41D11

22 38

78

21-22
13-14

3.0

5.4

6.1

33

0.240

0.240

0.275

0.280

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

38
1SBC141157C0202

O 22

22
133

134
34

60
L0055D

L0049D

63

57.5
32

50
120
L0048D

43

L0043D

31

L0042D

15

L1293DG

L0040D

10

107

cable inlet

30
40

44

37

O 5.3

L0061D

20

10
5

O 12

O 22

30

64

20

16

60

76.5

O 10

61.5
56
41

16

30

L0060D

O 7.3

16

L0054D

16

6.5

5.3

Dimensions (mm)

LS4..M.. Limit Switches


Metal Casing IP66 - 40 mm Width
1 Cable Inlet for Cable Gland
Movement to be detected:

30 Cam Translation Movement

Actuator

22 stainless steel
roller lever

Fully Direction Trans.

Adjustable 22
plastic roller lever

Conformity /
(N.C. contact with positive opening operation) EN 50041 (A shape)
Maximum actuation speed
1.5 m/s
Min. force / torque: - actuation
0.15 N.m
- positive opening operation
0.30 N.m

Adjustable 6
plastic rod lever

Spring rod

EN 50041 (D shape)
1.5 m/s
0.15 N.m
0.30 N.m

1.5 m/s
0.15 N.m
0.30 N.m

Multidirectional

1 m/s
0.18 N.m

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

Snap action contacts

LS4

Type

M42B11

LS4

M51B11

LS4

M72B11

LS4

M91B11

21

13

0 20 33

Zb
22

14

Non-overlapping
Slow action contacts

Zb

0 20 33

M42D11

Weight (packing per unit)

49

78

0 20 33

22 38

78

78

0 9 21

22 38

LS4

78

32

21-22
13-14
21-22
13-14

M51D11

21-22
13-14

kg

49

21-22
13-14
21-22
13-14

LS4

21-22
13-14

Operation
diagram

22

14

78

21-22
13-14
21-22
13-14

LS4

Type

21

13

49

21-22
13-14
21-22
13-14

Operation
diagram

M72D11

22 38

LS4

78

21-22
13-14

M91D11

12

32

21-22
13-14

33

33

33

0.280

0.290

0.285

19

0.235

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

7
58
53

O7

130

60

200

195

210 Maxi

45

280 Maxi

68...124

O 1.3

10

133

22

cable inlet

22

63

60

76.5

22

61.5
56
41

O 22

O6

138...194

O 7.3

O 22

O 5.3

48.5
16

16

6.5

5.3

60
L0081D

L0080D

L0077D

L0076D

L0067D

L0066D

43

L0061D

31

L0060D

60

15

L1293DG

L0040D

30
40

39
1SBC141157C0202

LS7..M.. Limit Switches


Metal Casing IP66 - 60 mm Width
3 Cable Inlets for Cable Gland
Movement to be detected:

On end

Actuator

30 Cam Translat.

Metal plunger

Conformity /
(N.C. contact with positive opening operation)
Maximum actuation speed
Min. force / torque: - actuation
- positive opening operation

11 metal roller
plunger

Unidirectional 30 Cam Translation

12.5 plastic roller lever 22 plastic roller lever


on steel plunger
on steel plunger

0.5 m/s
15 N
45 N

0.3 m/s
12 N
41 N

1 m/s
7N
24 N

1 m/s
7N
24 N

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT

Snap action contacts


13

22

M12B11

LS7

21

5.6 mm

Weight (packing per unit)

kg

0 3.0 4.8

M11D11

M31B11

LS7

7.7

9.6 mm

1.9 3.5

5.6 mm

0 4.9 9.0

14.5 21.0 mm

21-22
13-14
21-22
13-14

LS7

21-22
13-14

Operation
diagram

22

4.3

21-22
13-14
21-22
13-14

LS7

Type

Zb
14

LS7

21-22
13-14
21-22
13-14

Operation
diagram

Non-overlapping
Slow action contacts
13

M11B11

0 1.7 2.7

Zb
14

LS7

Type

M38B11

21

M12D11

3.4 6.3

LS7

9.6 mm

21-22
13-14

0 8.8 15.0

23.2

32.0 mm

21-22
13-14
21-22
13-14

M31D11

6.0 10.5

LS7

21.0 mm

21-22
13-14

M38D11

10.6 18.5

32.0 mm

21-22
13-14

15.1

2.8

5.1

8.6

0.270

0.280

0.265

0.270

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

12.5

40
1SBC141157C0202

51
O 22

12.5

L0982D

105.5
L0978D

93.5
L0977D

L0976D

88.5
L0975D

L0974D

31

39

O 12.5

3.5

30

20

12.5

12.5
O 11
31

25

20
36

30

74.5

14

L1294DG

59

L1021D

52

12.5

O8

42

20

54.5

40

17...23 29...35

cable inlet

22

L0981D

20

L0973D

O 5.2

LS7..M.. Limit Switches


Metal Casing IP66 - 60 mm Width
3 Cable Inlets for Cable Gland
Movement to be detected:

30 Cam Translat.

Fully directional Trans.

18 plastic roller
with bent lever

Adjustable 3 stainless
steel rod lever

Actuator
Conformity /
(N.C. contact with positive opening operation)
Maximum actuation speed
Min. force / torque: - actuation
- positive opening operation

Multidirectional

Spring rod

Pull action
with ring

1.5 m/s
0.1 N.m
0.32 N.m

Pull action

1.5 m/s
0.1 N.m
0.32 N.m

1 m/s
0.12 N.m

0.5 m/s
30 N

Additional Technical Data


LS type code to be complete with the cable inlet code ............ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT

Snap action contacts


13

22

M71B11

LS7

21

74

0 17 31

M45D11

M91B11

LS7

Weight (packing per unit)

47

74

0 12 23

21 37

74

M98B11-A

0 0.9 2.0

21 37

LS7

74

5.6 mm

21-22
13-14
21-22
13-14

M71D11

21-22
13-14

kg

36

21-22
13-14
21-22
13-14

LS7

21-22
13-14

Operation
diagram

22

47

21-22
13-14
21-22
13-14

LS7

Type

Zb
14

LS7

21-22
13-14
21-22
13-14

Operation
diagram

Non-overlapping
Slow action contacts
13

M45B11

0 17 31

Zb
14

LS7

Type

21

M91D11

14

LS7

36

21-22
13-14

M98D11-A
1.0

5.6 mm

21-22
13-14

1.9

30

30

21

0.335

0.380

0.315

0.350

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Dimensions (mm)

Open contact

Tearing withstand of:


- operating head: 200 daN
- ring: 40 daN

12.5
12.5

5.5

36

O 1.2

17.5

128.5

170

12.5

74

189.5

135

Max. 232

L1007D

L1004D

42
L1008D

Max. 177.5

17.5

36

L1003D

36

O 6.3

L0998D

14

O3

L0997D

59

O 27

L0988D

52

L1294DG

42

115.5

61

54.5

40

O 18

cable inlet

22

48.8
15.5
5.5

L0987D

20

L1021D

O 5.2

41
1SBC141157C0202

Interrupteurs de position de scurit - languette (cl)


Double isolation - Botier plastique IP65 - Largeurs 30 et 40 mm
Botier mtallique IP66 - Largeurs 30 et 40 mm
Applications
Simples d'emploi, les interrupteurs de position lectromcaniques offrent des qualits spciques :
Fonctionnement visible.
Aptitude la commutation des courants forts (courant thermique conventionnel 10 A).
Ouverture assure du ou des contacts "O" (N.C.) lorsque la languette est retire de l'interrupteur.
Blocs de contacts manuvre positive d'ouverture du contact ou des contacts ouverture "O" (N.C.) (symbolisation
).
Sparation lectrique des contacts.
Prcision sur les points de fonctionnement (fidlit).
Immunit aux perturbations lectromagntiques.
Ces particularits en font les organes privilgis pour le contrle et la protection sur les machines industrielles sans inertie o le temps
d'arrt est infrieur au temps d'accs la zone dangereuse. Utilisation sur protecteurs coulissants ou pivotants (capots, carters, portes, grilles, etc.).
Ils contribuent la protection de l'oprateur, intervenant sur une machine dangereuse, en ouvrant le circuit de commande. Le retrait de la
languette (cl) par l'ouverture du protecteur mobile provoque l'arrt immdiat de l'entranement de la machine.
Associs d'autres interrupteurs de position standard et des dispositifs de commutation de scurit, ils permettent de raliser des circuits d'automatisme rpondant la norme EN 954-1.
Ils respectent les exigences des Directives europennes (Basse Tension, Machines et Compatibilit Electromagntique) et sont conformes aux
normes europennes et internationales.

Description
Les interrupteurs de position de scurit avec cl :
- LS3..P..-S (largeur 30 mm) et LS4..P..-S (largeur 40 mm), en matire thermoplastique UL-V0 renforce de fibre de verre, offrent la double isolation
et un indice de protection IP65.
- LS3..M..-S (largeur 30 mm), en alliage de zinc (zamack), offrent un indice de protection IP66.
- LS4..M..-S (largeur 40 mm), en alliage d'aluminium, offrent un indice de protection IP66.
2 variantes de ttes de commande :
Orientable tous les 90 par 4 vis 3 pour (L3..P), par 4
vis 4 pour (L4..P), par 4 vis M3 pour (L3..M) et par 4
vis M4 pour (L4..M)
Pivotante de 0 360 avec 1 vis M3 (seulement
LS3..P81 ou LS3..M81)

7 variantes de languette (cl) (pour LS3..P ou LS3..M) et


5 variantes de languette (cl) (pour LS4..P ou LS4..M)
commander sparment :
Cl coude angle droit (fixation 13 ou 22 mm)
Cl droite (fixation 13 ou 22 mm)
Cl droite ou coude angle droit avec amortisseur
Cl coude ajustable

Botier :
Largeur 30 mm avec dimensions normalises du botier,
correspondant la norme EN 50047.
Largeur 40 mm avec dimensions normalises du botier,
correspondant la norme EN 50041.

Fixation du botier :
2 vis M4 en partie haute pour largeur 30 mm
2 ou 4 vis M5 pour largeur 40 mm
Couvercle :
Fermeture par 1 vis 3 pour LS3..P..-S
Fermeture par 3 vis M3 pour LS3..M..-S
Fermeture auto-blocante pour LS4..P..-S
Fermeture par 2 vis M4 pour LS4..M..-S
Joint ralis d'une seule pice pour viter les ruptures d'tanchit

L0490D

Blocs de 2 ou 3 contacts :
Configuration des contacts : 1 N.O. + 1 N.C., 2 N.C.,
1 N.O. + 2 N.C. ou 3 N.C. (seulement LS4..P et LS4..M)
Manoeuvre positive d'ouverture
Action brusque (seulement pour les blocs de 2 contacts)
Action dpendante
Les deux contacts sont lectriquement spars

Raccordement lectrique en diffrentes variantes :


1 entre de cble (LS30P/M & LS40P/M) pour presse-toupe
Pg 13.5
1 entre de cble (LS31P/M) pour presse-toupe Pg 11
1 entre de cble (LS32P/M) pour presse-toupe ISO 16
1 entre de cble (LS33P/M & LS43P/M) pour presse-toupe
ISO 20
1 entre de cble (LS35P) par adaptateur plastique 1/2" NPT
1 entre de cble (LS35M & LS45P/M) pour presse-toupe 1/2" NPT
Appropri pour raccordement par conduit direct mais seulement
avec l'utilisation d'un adaptateur facultativement fourni par le
fabricant (sur demande)

D 1 1

Bornes de raccordement :
Vis M3.5 tte (+,) pozidriv 2
(Serre-fils solidaires des ttes de vis)
Marquage conforme aux normes IEC 60947-1,
IEC 60947-5-1, EN 50005 et EN 50013
Borne pour conducteur de protection, place
proximit de l'entre de cble et marque :
(LS3..M & LS4..M seulement)
Vis M3.5 tte (+,) pozidriv 2
(Serre-fils solidaire de la tte de vis)

Type

Exemple :

L S

3 1

L S

P
P

Interrupteur de position (Limit Switch) ........................................LS


Largeur de botier : 30 mm ............................................................................ 3
1 entre de cble pour presse-toupe Pg 13.5 ....................................................0
1 entre de cble pour presse-toupe Pg 11 .......................................................1
1 entre de cble M16 x 1.5 pour presse-toupe ISO 16 ....................................2
1 entre de cble M20 x 1.5 pour presse-toupe ISO 20 ....................................3
1 entre de cble par adaptateur plastique 1/2" NPT pour (LS35P) ou 1/2" NPT
pour presse-toupe (LS35M) ................................................................................5
Largeur de botier : 40 mm ............................................................................ 4
1 entre de cble pour presse-toupe Pg 13.5 ....................................................0
1 entre de cble pour presse-toupe ISO 20 .....................................................3
1 entre de cble pour presse-toupe 1/2" NPT..................................................5

Botier Plastique................................................................................................................. P
Botier Mtallique ...............................................................................................................M

42
1SBC141157C0302

8 0

S
S ............Appareil de Scurit
Types de contacts :
11 ........... 1 contact N.O. + 1 contact N.C.
12 ........... 1 contact N.O. + 2 contacts N.C. (pour LS4..P.. ou LS4..M..)
02 ........... 2 contacts N.C.
03 ........... 3 contacts N.C. (pour LS4..P.. ou LS4..M..)
Action brusque :
B ...........Zb Brusque
Action dpendante (lent) :
L ............Lent / Simultan (pour 1 N.O. + 1 N.C. et 2 N.C. uniquement)
D ...........Zb Dcal action retarde
C ...........Zb Chevauchant fermeture avance (pour 1 N.O. + 1 N.C. uniquement)
Ttes de commande (voir le panorama)
80 ............. Orientable tous les 90
81 ............. Pivotante de 0 360 (seulement pour LS3..P & LS3..M)

Interrupteurs de position de scurit - avec axe ou levier


Double isolation - Botier plastique IP65 - Largeur 30 mm
Botier mtallique IP66 - Largeur 30 mm
Applications
Simples d'emploi, les interrupteurs de position avec axe rotatif ou levier offrent des qualits spciques :
Fonctionnement visible.
Aptitude la commutation des courants forts (courant thermique conventionnel 10 A).
Ouverture des contacts "O" (N.C.) pour un angle de rotation trs faible : 7.
Blocs de contacts manoeuvre positive d'ouverture du ou des contacts "O" (N.C.) (symbolisation
).
Sparation lectrique des contacts.
Prcision sur les points de fonctionnement (fidlit).
Immunit aux perturbations lectromagntiques.
Ces particularits en font les organes privilgis pour le contrle et la protection sur des machines industrielles lgres sans inertie quipes
de protecteurs mouvement angulaire (portes, grilles charnires, capots ou carters rotatifs, etc.). Dtection par l'axe de rotation ou par
l'intermdiaire d'un levier .
L'ouverture du protecteur mobile assure la protection de l'oprateur, par l'arrt immdiat de l'entranement de la machine.
Ils sont parfaitement appropris pour la mise en conformit du parc machines existant, car ils peuvent se monter sur les dispositifs de protection
dj installs.
Associs d'autres interrupteurs de position standard et des dispositifs de commutation de scurit, ils permettent de raliser des circuits d'automatismes correspondant la norme EN 954-1.
Ils respectent les exigences des Directives europennes (Basse Tension, Machines et Compatibilit Electromagntique) et sont conformes aux
normes europennes et internationales.

Description
LS3..P75..-S LS3..P77..-S, interrupteurs de position de scurit en matire thermoplastique UL-V0 renforce de fibre de verre, offrent la double
isolation et un indice de protection IP65.
LS3..M75..-S LS3..M77..-S, interrupteurs de position de scurit en alliage de zing (zamack), offrent un indice de protection IP66.
Fixation du botier (Plastique ou Mtallique) :
2 vis M4 en partie haute

3 variantes de ttes de commande :


Axe rotatif en acier zingu
Axe rotatif en inox
Levier coud affleurant en acier zingu
Assemblage par 4 vis 3 pour LS3..P..-S
Assemblage par 4 vis M3 pour LS3..M..-S

Botier (Plastique ou Mtallique) :


Largeur 30 mm avec dimensions normaliss du botier
correspondant la norme EN 50047
Blocs de 2 contacts :
Configuration des contacts: 1 N.O. + 1 N.C. ou 2 N.C.
Manoeuvre positive d'ouverture
Action dpendante ou action brusque
Les 2 contacts sont spars lectriquement

Couvercle :
Fermeture par 1 vis 3 pour LS3..P..-S
Fermeture par 3 vis M3 pour LS3..M..-S
Joint ralis d'une seule pice pour viter les ruptures d'tanchit

Bornes de raccordement :
Vis M3.5 tte (+,-) posidriv 2
(Serre-fils solidaire des ttes de vis)
Marquage conforme aux normes IEC 60947-1,
IEC 60947-5-1, EN 50005 et EN 50013
L0491D

Borne pour conducteur de protection, place


proximit de l'entre de cble et marque :
(LS3..M seulement)
Vis M3.5 tte (+,) pozidriv 2
(Serre-fils solidaire de la tte de vis)

Type

Exemple :

Raccordement lectrique :
(LS30P/M) 1 entre de cble pour presse-toupe Pg 13.5
(LS31P/M) 1 entre de cble pour presse-toupe Pg 11
(LS32P/M) 1 entre de cble pour presse-toupe ISO 16
(LS33P/M) 1 entre de cble pour presse-toupe ISO 20
(LS35P) 1 entre de cble par adaptateur plastique 1/2" NPT
(LS35M) 1 entre de cble pour presse-toupe 1/2" NPT
Appropri pour raccordement par conduit direct mais
seulement avec l'utilisation d'un adaptateur facultativement
fourni par le fabricant (sur demande)

L S

3 1

L S

7 5

Interrupteur de position (Limit Switch) ........................................LS

Largeur de botier : 30 mm ............................................................................ 3


1 entre de cble pour presse-toupe Pg 13.5 ....................................................0
1 entre de cble pour presse-toupe Pg 11 .......................................................1
1 entre de cble M16 x 1.5 pour presse-toupe ISO 16 ...................................2
1 entre de cble M20 x 1.5 pour presse-toupe ISO 20 ....................................3
1 entre de cble par adaptateur plastique 1/2" NPT (LS35P) ou pour pressetoupe 1/2" NPT (LS35M) ....................................................................................5

Botier Plastique................................................................................................................. P
Botier Mtallique ...............................................................................................................M

Ttes de commande :
Axe rotatif en acier zingu ................................................................................................................. 75
Axe rotatif en inox .............................................................................................................................. 76
Levier coud affleurant en acier zingu ............................................................................................. 77

D 1 1

S
S

S ............Appareil de Scurit

Types de contacts:
11 ........... 1 contact N.O. + 1 contact N.C.
02 ........... 2 contacts N.C.

Action brusque :
B ...........Zb Brusque
Action dpendante (lent) :
L ............Lent / Simultan
D ...........Zb Dcal fermeture retarde
C ...........Zb Chevauchant fermeture avance

43
1SBC141157C0302

Interrupteurs de position de scurit - commande par cble


Double isolation - Botier plastique IP65 - Largeur 30 mm
Botier mtallique IP66 - Largeurs 30, 40 et 60 mm
Applications
Simples demploi, les interrupteurs de position de scurit commande par cble pour arrt durgence avec accrochage et rarmement
manuel offrent des qualits speciques :
Aptitude la commutation des courants forts (courant thermique conventionnel 10 A).
Blocs de contacts manuvre positive d'ouverture du contact ou des contacts ouverture "O" (N.C.) (symbolisation
).
Sparation lectrique des contacts.
Prcision sur les points de fonctionnement (fidlit).
Immunit aux perturbations lectromagntiques.
Ces particularits en font les organes privilgis pour le contrle et la protection dans des lieux techniques (laboratoires dessais, lignes
de peinture,...) et sur les machines industrielles (presses , bandes transporteuses, machines de transferts,...) pouvant prsenter des
risques ou des phnomnes dangereux en fonctionnement.
En tout point de sa zone de travail, loprateur doit pouvoir actionner (tirer) facilement le cble pour commander lordre darrt de la
machine ou le travail en cours.

Associs des interrupteurs de position et des dispositifs de commutation de scurit, ils permettent de raliser des circuits d'automatisme rpondant
la norme EN 954-1.
Ils respectent les exigences des Directives europennes (Basse Tension, Machines et Compatibilit Electromagntique) et sont conformes aux
normes europennes et internationales.

Description
Interrupteurs de position de scurit commande par cble pour arrt durgence avec accrochage et rarmement manuel :
LS3..P..-SCR (largeur 30 mm), en matire thermoplastique UL-V0 renforce de fibre de verre, offrent la double isolation
protection IP65.
LS3..M..-SCR (largeur 30 mm), en alliage de zinc (zamack), offrent un indice de protection IP66.
LS4..M..-SCR (largeur 40 mm) et LS6..M..-SCR (largeur 60 mm), en alliage d'aluminium, offrent un indice de protection IP66.

et un indice de

Ttes de commande :
Assemblage par 4 vis M3 pour LS3..M
Assemblage par 4 vis 3 pour LS3..P
Assemblage par 4 vis M4 pour largeurs 40 & 60 mm

Bouton bleu de rarmement manuel


Botier :
Largeur 30 mm avec dimensions normalises du botier,
correspondant la norme EN 50047
Largeur 40 mm avec dimensions normalises du botier,
correspondant la norme EN 50041
Largeur 60 mm

Fixation du botier :
2 vis M4 en partie haute pour largeur 30 mm
2 ou 4 vis M5 pour largeur 40 mm
2 vis M5 en partie haute pour largeur 60 mm

Blocs de 2 ou 3 contacts :
Configuration des contacts : 1 N.O. + 1 N.C., 2 N.C.,
1 N.O. + 2 N.C. or 3 N.C. (seulement LS4..M..-SCR & LS6..M..-SCR)
Manoeuvre positive d'ouverture
Action brusque (seulement pour les blocs de 2 contacts)
Action dpendante
Les deux contacts sont lectriquement spars

Couvercle :
Fermeture par 1 vis 3 pour LS3..P..-SCR
Fermeture par 3 vis M3 pour LS3..M..-SCR
Fermeture par 2 vis M4 pour LS4..M..-SCR
Fermeture par 4 vis M4 pour LS6..M..-SCR
Joint ralis d'une seule pice pour viter les ruptures
d'tanchit

Bornes de raccordement :
Vis M3.5 tte (+,) pozidriv 2
(Serre-fils solidaires des ttes de vis)
Marquage conforme aux normes IEC 60947-1,
IEC 60947-5-1, EN 50005 et EN 50013

Raccordement lectrique :
* entre de cble (LS30P/M, LS40M & LS60M) pour
presse-toupe Pg 13.5
1 entre de cble (LS31P/M) pour presse-toupe Pg 11
1 entre de cble (LS32P/M) pour presse-toupe ISO 16
* entre de cble (LS33P/M, LS43M & LS63M) pour pressetoupe ISO 20
1 entre de cble (LS35P) par adaptateur plastique 1/2" NPT
* entre de cble (LS35M, LS45M & LS65M) pour pressetoupe 1/2" NPT
* 1 entre de cble (LS3.P/M & LS4.M) & 3 entres de cble (LS6.M)
Appropri pour raccordement par conduit direct mais
seulement avec l'utilisation d'un adaptateur facultativement
fourni par le fabricant (sur demande)

Borne pour conducteur de protection, place proximit


(LS3..M..-SCR,
de l'entre de cble et marque :
LS4..M..-SCR & LS6..M..-SCR seulement)
Vis M3.5 tte (+,) pozidriv 2
(Serre-fils solidaire de la tte de vis)

Type

Exemple :

L S

3 1

L S

9 8

D 1 1

SCR

Interrupteur de position (Limit Switch) ........................................LS


Largeur de botier : 30 mm ............................................................................ 3
1 entre de cble pour presse-toupe Pg 13.5 ....................................................0
1 entre de cble pour presse-toupe Pg 11 .......................................................1
1 entre de cble M16 x 1.5 pour presse-toupe ISO 16 ....................................2
1 entre de cble M20 x 1.5 pour presse-toupe ISO 20 ....................................3
1 entre de cble par adaptateur plastique 1/2" NPT pour (LS35P) ou 1/2" NPT
pour presse-toupe (LS35M) ................................................................................5
Largeur de botier : 40 mm ............................................................................ 4
Largeur de botier : 60 mm ............................................................................ 6
1 entre de cble (LS40M) ou 3 (LS60M) pour presse-toupe Pg 13.5 ...............0
1 entre de cble (LS43M) ou 3 (LS63M) pour presse-toupe ISO 20.................3
1 entre de cble (LS45M) ou 3 (LS65M) pour presse-toupe 1/2" NPT .............5
Botier Plastique................................................................................................................. P
Botier Mtallique ...............................................................................................................M

44
1SBC141157C0302

SCR

SCR ...... Appareil de Scurit avec anneau


Types de contacts :
11 ........... 1 contact N.O. + 1 contact N.C.
12 ........... 1 contact N.O. + 2 contacts N.C. (pour LS4..M.. ou LS6..M.. )
02 ........... 2 contacts N.C.
03 ........... 3 contacts N.C. (pour LS4..M.. ou LS6..M.. )
Action brusque :
B ...........Zb Brusque (pour 1 N.O. + 1 N.C. et 2 N.C. uniquement)
Action dpendante (lent) :
L ............Lent / Simultan
D ...........Zb Dcal action retarde
C ...........Zb Chevauchant fermeture avance (pour 1 N.O. + 1 N.C. uniquement)
Ttes de commande :
98 ............. avec anneau

Interrupteurs de position de scurit - languette (cl)


Botier plastique IP65 - Largeurs 30 mm et 40 mm
Botier mtallique IP66 - Largeurs 30 mm et 40 mm
LS30P : 1 entre de cble pour presse-toupe Pg 13.5 .........
LS31P : 1 entre de cble pour presse-toupe Pg 11 ............
LS32P : 1 entre de cble pour presse-toupe ISO 16 .............
LS33P : 1 entre de cble pour presse-toupe ISO 20 .............
LS35P : 1 entre de cble par adaptateur plastique 1/2" NPT ..

0
1
2
3
5

.............................................
.............................................
.............................................
.............................................
.............................................

0
0
0
2
2

2
1
3
2
1

LS30M : 1 entre de cble pour presse-toupe Pg 13.5 ...........


LS31M : 1 entre de cble pour presse-toupe Pg 11 ..............
LS32M : 1 entre de cble pour presse-toupe ISO 16 .............
LS33M : 1 entre de cble pour presse-toupe ISO 20 .............
LS35M : 1 entre de cble pour presse-toupe 1/2" NPT ..........

0
1
2
3
5

.............................................
.............................................
.............................................
.............................................
.............................................

1
1
1
3
3

8
7
9
8
7

SB8119CM

Rfrences de commande Blocs de contacts


13

21

14

22

LS30P80D11-S

11

21

12

22

Zb
D11

Botier plastique - 30 mm
IP65

Botier mtallique - 30 mm
IP66

Produit sans languette (cl)

Type

Rf. Commerciale

Masse
kg (1)

code entre de cble

code entre de cble

Condmt
1 pice

Zb
L02

1SBC5 9230 2F030M

Botier plastique avec tte orientable tous les 90


1

LS3

P80D11-S

1SBV03

80R1411

0.080

LS3

P80L02-S

1SBV03

80R1302

0.080

Botier mtallique avec tte orientable tous les 90

LS32M80D11-S

LS3

M80D11-S

1SBV03

80R1411

0.180

LS3

M80L02-S

1SBV03

80R1302

0.180

(1) Pour LS35P ajouter 0.007 kg.

LS40P : 1 entre de cble pour presse-toupe Pg 13.5 ............. 0 ............................................. 0 5


LS43P : 1 entre de cble pour presse-toupe ISO 20 ........... 3 ............................................. 0 7
LS45P : 1 entre de cble pour presse-toupe 1/2" NPT ........ 5 ............................................. 2 4

Botier plastique - 40 mm
IP65

LS40M : 1 entre de cble pour presse-toupe Pg 13.5.......... 0 ............................................. 1 1


LS43M : 1 entre de cble pour presse-toupe ISO 20 ............. 3 ............................................. 1 6
LS45M : 1 entre de cble pour presse-toupe 1/2" NPT ........ 5 ............................................. 3 1

Botier mtallique - 40 mm
IP66

1SBC5 9153 2F030M

Rfrences de commande Blocs de contacts


13 21

31

22

32

14

D12

11

21 31

12

22 32

Produit sans languette (cl)

Type

Rf. Commerciale

Masse
kg

code entre de cble

code entre de cble

Condmt
1 pice

L03

Botier plastique avec tte orientable tous les 90

LS40P80D12-S

LS4

P80D12-S

1SBV03

80R1412

0.155

LS4

P80L03-S

1SBV03

80R1303

0.155

1SBC5 9232 2F030M

Botier mtallique avec tte orientable tous les 90


1

LS4

M80D12-S

1SBV03

80R1412

0.210

LS4

M80L03-S

1SBV03

80R1303

0.210

Rfrences de commande - Languettes (Cls)


Description de la cl

Fixation Type
mm

Rf. Commerciale

Masse
kg
Packing
1 pice

Languette (cl) pour LS3..P.. ou LS3..M..


LS40M80D12-S

Coude angle droit

13

LSA30P05

1SBV 048 605 R1000

0.011

Droite

0.011

13

LSA30P06

1SBV 048 606 R1000

Coude angle droit avec amortisseur 15

LSA30P07

1SBV 048 607 R1000

0.014

Droite avec amortisseur

15

LSA30P08

1SBV 048 608 R1000

0.014

Coude ajustable

40

LSA30P09

1SBV 048 609 R1000

0.022

18

Languette (cl) pour LS4..P.. ou LS4..M..

LSA30P08

Coude angle droit

13

LSA40X05

1SBV 048 805 R1000

0.014

Droite

13

LSA40X06

1SBV 048 806 R1000

0.014

Coude angle droit avec amortisseur 15

LSA40X07

1SBV 048 807 R1000

0.017

Droite avec amortisseur

15

LSA40X08

1SBV 048 808 R1000

0.017

Coude ajustable

40

LSA40X09

1SBV 048 809 R1000

0.025
45
1SBC141157C0302

Interrupteurs de position de scurit - avec axe ou levier

SB8126CM

Double Isolation - Botier plastique IP65 - Largeur 30 mm


Botier mtallique IP66 - Largeur 30 mm

LS30P75D11-S

LS30P : 1 entre de cble pour presse-toupe Pg 13.5 ..........


LS31P : 1 entre de cble pour presse-toupe Pg 11.............
LS32P : 1 entre de cble pour presse-toupe ISO 16 ...........
LS33P : 1 entre de cble pour presse-toupe ISO 20 ...........
LS35P : 1 entre de cble par adaptateur plastique 1/2" NPT ..

0
1
2
3
5

.............................................
.............................................
.............................................
.............................................
.............................................

0
0
0
2
2

2
1
3
2
1

LS30M : 1 entre de cble pour presse-toupe Pg 13.5..........


LS31M : 1 entre de cble pour presse-toupe Pg 11 ............
LS32M : 1 entre de cble pour presse-toupe ISO 16 ...........
LS33M : 1 entre de cble pour presse-toupe ISO 20 ...........
LS35M : 1 entre de cble pour presse-toupe 1/2" NPT ..........

0
1
2
3
5

.............................................
.............................................
.............................................
.............................................
.............................................

1
1
1
3
3

8
7
9
8
7

Botier plastique - 30 mm
IP65

Botier mtallique - 30 mm
IP66

Rfrences de commande
Blocs de contacts
13

21

14

22

11

21

12

22

Type

Rf. Commerciale

Masse
kg (1)

code entre de cble

code entre de cble

Condmt
1 pice

Zb
D11

L02

1SBC5 9251 1F030M

Botier plastique avec axe rotatif (zingu)


1

LS3

P75D11-S

1SBV03

75R1411

0.090

LS3

P75L02-S

1SBV03

75R1302

0.090

Botier plastique avec axe rotatif en inox


1

LS3

P76D11-S

1SBV03

76R1411

0.090

LS3

P76L02-S

1SBV03

76R1302

0.090

LS32M76D11-S

Botier mtallique avec axe rotatif (zingu)


1

LS3

M75D11-S

1SBV03

75R1411

0.190

LS3

M75L02-S

1SBV03

75R1302

0.190

Botier mtallique avec axe rotatif en inox


1

LS3

M76D11-S

1SBV03

76R1411

0.190

LS3

M76L02-S

1SBV03

76R1302

0.190

Botier plastique avec levier (zingu)


1

LS3

P77D11-S

1SBV03

77R1411

0.110

LS3

P77L02-S

1SBV03

77R1302

0.110

SB8115CM

Botier mtallique avec levier (zingu)

LS30P77D11-S

46
1SBC141157C0302

LS3

M77D11-S

1SBV03

77R1411

0.210

LS3

M77L02-S

1SBV03

77R1302

0.210

(1) Pour LS 35P ajouter 0.007 kg.

Interrupteurs de position de scurit - commande par cble

1SBC 14100 4F0014

Double isolation - Botier plastique IP65 - Largeur 30 mm


Botier mtallique IP66 - Largeurs 30, 40 et 60 mm
LS30P : 1 entre de cble pour presse-toupe Pg 13.5 .............
LS31P : 1 entre de cble pour presse-toupe Pg 11 ................
LS32P : 1 entre de cble pour presse-toupe ISO 16 ...........
LS33P : 1 entre de cble pour presse-toupe ISO 20 ...........
LS35P : 1 entre de cble par adaptateur plastique 1/2" NPT ..

0 ............................................. 0 2

LS30M : 1 entre de cble pour presse-toupe Pg 13.5..........


LS31M : 1 entre de cble pour presse-toupe Pg 11 ............
LS32M : 1 entre de cble pour presse-toupe ISO 16 ..........
LS33M : 1 entre de cble pour presse-toupe ISO 20 ...........
LS35M : 1 entre de cble pour presse-toupe 1/2" NPT ........

0 ............................................. 1 8

Blocs de contacts
21

13

LS32M98D11-SCR

11

21

12

22

1 ............................................. 0 1
2 ............................................. 0 3

Botier plastique - 30 mm
IP65

3 ............................................. 2 2
5 ............................................. 2 1
1 ............................................. 1 7
2 ............................................. 1 9

Botier mtallique - 30 mm
IP66

3 ............................................. 3 8
5 ............................................. 3 7

Type

Rf. Commerciale

Masse
kg (1

code entre de cble

code entre de cble

Condmt
1 pice

Zb
22

14

D11

L02

Botier plastique - Commande par cble pour arrt durgence avec accrochage et rarmement manuel
1

LS3

P98D11-SCR

1SBV03

98R1411

0.115

LS3

P98L02-SCR

1SBV03

98R1302

0.115

1SBC 14100 4F0014

Botier mtallique - Commande par cble pour arrt durgence avec accrochage et rarmement manuel
1

LS3

M98D11-SCR

1SBV03

98R1411

0.270

LS3

M98L02-SCR

1SBV03

98R1302

0.270

(1) pour LS 35P ajouter 0.007 kg.


LS40M98D11-SCR

LS40M : 1 entre de cble pour presse-toupe Pg 13.5.......... 0 ............................................. 1 1


LS43M : 1 entre de cble pour presse-toupe ISO 20 ........... 1 ............................................. 1 6
LS45M : 1 entre de cble pour presse-toupe 1/2" NPT ........ 2 ............................................. 3 1

Botier mtallique - 40 mm
IP66

LS60M: 3 entres de cble pour presse-toupe Pg 13.5 ........ 0 ............................................. 1 3


LS63M: 3 entres de cble pour presse-toupe ISO 20 .......... 1 ............................................. 1 5
LS65M : 3 entres de cble pour presse-toupe 1/2" NPT ...... 2 ............................................. 3 3

Botier mtallique - 60 mm
IP66

1SBC 1410 05F0014

Blocs de contacts

LS60M98D12-SCR

13 21

31

22

32

14

D12

11

21 31

12

22 32

Type

Rf. Commerciale

Masse
kg

code entre de cble

code entre de cble

Condmt
1 pice

L03

Botier plastique - Commande par cble pour arrt durgence avec accrochage et rarmement manuel
1

LS4

M98D12-SCR

1SBV03

98R1412

0.270

LS4

M98L03-SCR

1SBV03

98R1303

0.270

Botier mtallique - Commande par cble pour arrt durgence avec accrochage et rarmement manuel
1

LS6

M98D12-SCR

1SBV03

98R1412

0.300

LS6

M98L03-SCR

1SBV03

98R1303

0.300

Accessoires
LSR5242

LSR5444
LSR5343

LSR5551

Description des accessoires

Type

Rf. Commerciale

Masse
kg
Condmt
1 pice

Serre-cble D5
Renfort de boucle D5
Support de cble M8 x 59
Ridoir (tendeur) M6
Ressort dextrmit (LS3...P, LS3...M)
Ressort dextrmit (LS4...M, LS6...M)
Cble rouge D5
10.50 mters
longueur
15.50 mters
25.50 mters
51.00 mters
102.00 mters

LSR5242
LSR5343
LSR5444
LSR5141
LSR5845
LSR5846
LSR5547
LSR5548
LSR5549
LSR5550
LSR5551

1SBV 047 800 R5242


1SBV 047 800 R5343
1SBV 047 800 R5444
1SBV 047 800 R5141
1SBV 047 800 R5845
1SBV 047 800 R5846
1SBV 047 800 R5547
1SBV 047 800 R5548
1SBV 047 800 R5549
1SBV 047 800 R5550
1SBV 047 800 R5551

0.060
0.005
0.080
0.080
0.050
0.050
0.580
0.860
1.410
2.790
5.600
47
1SBC141157C0302

Interrupteurs de position de scurit


languette (cl) ou avec axe ou levier
Courses et diagrammes de fonctionnement
PO
F1

CL
C2

PP

cl

CP

C1

extraction

PA

L0539D

C : course en millimtres

C : course en degrs

PO Position de repos :
position de l'organe de commande lorsque
aucune force extrieure ne lui est applique.

C : course en degrs

L0544D

L0537D

Diagramme pour contacts


dcals action dpendante :
CL
CP PP

C1 Course d'approche (course moyenne) :


distance entre la position repos PO et le point
d'action PA.

PA Point d'action :
position de l'organe de commande, sous
l'action de la force F1, au moment o les
contacts quittent leur tat initial de repos.

CP Course d'ouverture positive :


dplacement minimum de l'organe de commande, depuis la position de repos, pour
assurer la manuvre positive d'ouverture du
contact ouverture (N.C.).

PP Point d'ouverture positive :


position de l'organe de commande partir de
laquelle l'ouverture positive est assure.

C2 Course rsiduelle (course moyenne) :


distance entre le point d'action PA et la limite
de fin de course L.

L
Limite de n de course :
Position limite acceptable de l'organe de
commande sous l'action d'une force F1.

CL Course limite (course maximale) :


distance entre la position de repos PO et la
limite de fin de course L.

C1-1
Extraction cl
Insertion cl

21-22
13-14

C1-2

C : course

Note: C1-1 = course d'approche du contact 21-22,


C1-2 = course d'approche du contact 13-14.

L0538D

Exemples :
LS30P80L02-S
contacts simultans action dpendante

LS30P76D11-S
contacts dcals action dpendante
C

Diagramme pour contacts


dcals action dpendante :

0
CL
PP CP
C1-1

C
21-22

21-22

13-14

Diagramme
en millimtres / course de la cl
0

5.0

11-12
21-22

3.5

21.5 mm

Diagramme
en degrs / rotation du levier
21-22
13-14

90

31 6 6 31
15 0 15

C : course

Etat des contacts

90 21-22
13-14

21-22

Contact closed

21-22

Contact open

Contacts identification (example)

48
1SBC141157C0302

et

13-14

C1-2

Actionnement
Relchement

Interrupteurs de position de scurit


commande par cble pour arrt durgence
Courses et diagrammes de fonctionnement et installation
Po

Position de repos : position de lorgane de


commande (poussoir anneau) lorsque aucune
force extrieure ne lui est applique.

Pp

Point douverture positive : position de lorgane


de commande (poussoir anneau) partir de
laquelle louverture positive du (des) contact(s)
N.C. est assure

Position de mise en service (reprage vert) : le


systme de scurit est enclench (avec action
de tirer sur le bouton de rarmement bleu)

Position de mise en service


(reprage vert)
Cble en tension

P0

C0

CL

Ces

F1

STOP

21-22
13-14

R
Ces

PP STOP

L Limite de fin course : position limite acceptable de lorgane de commande (poussoir


anneau)

mm
L1402D

21-22
13-14

mm

Cp

CL
si le cble casse

C0 Course minimum pour armer le systme de


scurit et obtenir la position de mise en service
sous leffet dune force F
Cp Course douverture positive : course minimum
de lorgane de commande (poussoir anneau),
depuis la position de mise en service pour assurer
louverture positive du (des) contact(s) N.C.
Ces, Ces Course darrt durgence et daccrochage du systme de scurit : course minimum pour obtenir
larrt durgence et laccrochage du systme de
scurit sous leffet dune force F1.

Etats des contacts


21-22

Contact ferm

21-22

Contact ouvert

CL

Course maximum : distance entre la position de


mise service 0 et la limite de fin de course L.

CL

Distance entre la mise en service 0 et la position


de repos Po si le cble casse.

Identification des contacts (exemple)

Installation
Pour obtenir le fonctionnement correct de lappareil, merci de suivre les instructions suivantes :
1. Selon lemplacement de lappareil, si ncessaire, tourner la tte en dvissant les 4 vis de fixation afin que le bouton bleu de rarmement soit
accessible. Une fois la tte positionne, revissez les 4 vis avec un couple de serrage de 0,8 Nm.
2. Fixez solidement lappareil et les supports de cble sur des lments rigides afin que le cble soit bien guid. Insrer du cot lappareil un
ridoir et de lautre cot du cble un ressort dextrmit. Tendre le cble laide du ridoir jusqu faire apparatre sur le poussoir mtallique la
marque verte en bout de la partie rouge de la tte. (fig.1)
3. Tirez le bouton de rarmement bleu pour armer le systme de scurit et fermer les contacts de scurit.
4. Les contacts lintrieur de linterrupteur de position changeront dtat chaque fois que le cble aura t sollicit (par traction) comme montr
dans le diagramme ci-dessus.
5. Vrifiez que lappareil fonctionne correctement avant de mettre en marche la machine, en faisant les tests ci-dessous :
a) tirer doucement sur le cble, le bouton de rarmement bleu ne change pas de position mais le contact N.C. souvre et commande larrt
"normal" de la machine.
b) tirer sur le cble avec une force F1, le bouton de rarmement bleu change de position et commande larrt durgence de la machine avec
accrochage du systme de scurit.
c) pour remettre la machine en fonctionnement revenez au point N 2 et rpter lopration (si ncessaire).
6. Lutilisation de ces appareils implique le respect des normes : EN 1088, EN 292, EN 954-1.

Sries LS3..M98..-SCR et sries LS3..P98-SCR : L = 6 m maximum


Sries LS4..M98..-SCR et sries LS6..M98-SCR : L = 16 m maximum

(fig. 1)

Ridoir

Sries LS3..M98..-SCR et LS3..P98-SCR : L = 15 m maximum


Sries LS4..M98..-SCR et LS6..M98-SCR : L = 25 m maximum

L1408D

Ressort d'extrmit

G = 3 m maximum
G = 35 m maximum
L

49
1SBC141157C0302

Interrupteurs de position de scurit


Botier plastique
IP65 - Botier mtallique IP66
Caractristiques techniques
Caractristiques techniques gnrales
Botier Plastique

Botier Mtallique

Normes

IEC 60947-1, IEC 60947-5-1, EN 60947-1, EN 60947-5-1, UL 508,et CSA C22-2 No. 14

Homologations - Agrments

UL - CSA - CCC

Temprature de l'air proximit de l'appareil


en fonctionnement
pour stockage

C
C

-25 ... +70


-30 ... +80

Tenue climatique

Selon IEC 68-2-3 et brouillard salin selon IEC 68-2-11

Positions de montage

Toutes les positions sont autorises

Tenue aux chocs (selon IEC 68-2-27 et EN 60068-2-27)

Interrupteur de position avec languette (cl) : 10 g


Interrupteur de position avec axe rotatif ou levier et commande par cble : 40 g

5 g (10 ... 500 Hz) pas de changement d'tat des contacts > 100 s

(choc 1/2 sinusodal 11 ms) pas de changement d'tat des contacts

Tenue aux vibrations (selon IEC 68-2-6 et EN 60068-2-6)


Protection contre les chocs lectriques (selon IEC 536)

Classe II

Classe I

Degr de protection (selon IEC 529 et EN 60529)

IP65

IP66

500 (degr de pollution 3)


600
6

500 (LS4..M..), (LS6..M..), 400 (LS3..M..) - (degr de pollution 3)


600 (LS4..M..), (LS6..M..), 300 (LS3..M..)

Caractristiques lectriques
Tension assigne d'isolement Ui
selon IEC 60947-1 et EN 60947-1
selon UL 508, CSA C22-2 No. 14
Tension assigne de tenue aux chocs Uimp

V
kV

(selon IEC 60947-1 et EN 60947-1)

Courant thermique conventionnel sous enveloppe Ithe

10

Protection contre les court-circuits - fusibles types gG


A
Courant assign d'emploi
Ie / AC-15 selon IEC 60947-5-1
24 V - 50/60 Hz A
130 V - 50/60 Hz A
230 V - 50/60 Hz A
240 V - 50/60 Hz A
400 V - 50/60 Hz A
selon UL 508, CSA C22 N 14
Ie / DC-13 selon IEC 60947-5-1
24 V - d.c. A
110 V - d.c. A
250 V - d.c. A
selon UL 508, CSA C22 N 14
Positivit
Rsistance entre les contacts
m
Durabilit mcanique
Millions d'oprations
Frquence de manuvre maxi.
Cycles/h
Durabilit lectrique (selon IEC 60947-5-1 annexe C)
frquence de manuvre maxi
Cycles/h
facteur de marche
Caractristiques de connectique des blocs contacts
Bornes de raccordement
Capacit de raccordement 1 ou 2 x mm2 / AWG
Marquage des bornes

10

(selon IEC 60947-5-1 et EN 60947-5-1) ( < 40 C)

10
5.5
3.1
3
1.8
A 600
A 600 (LS4..M), (LS6..M) - A 300 (LS3..M)
2.8
0.6
0.27
Q 600
Q 600 (LS4..M), (LS6..M) - Q 300 (LS3..M)
Contacts manoeuvre positive d'ouverture selon IEC 60947-5-1 chapitre 3 et EN 60947-5-1
25
> 1 million
600
Catgories d'utilisation AC-15 et DC-13 (voir courbes et valeurs ci-dessous)
3600
0.5
Vis M3.5 tte (+,) pozidriv 2 avec serre-fils
0.5 mm2 / AWG 20 2.5 mm2 / AWG 14
Selon EN 50013

Durabilit lectrique en catgorie d'emploi AC-15


Action brusque

13

0.3

0.1
0.2 0.3

L0351DF

0.2

0.5

50
1SBC141157C0302

3
5
10
Courant (A)

0.5
0.3
0.2
L0350DF

Millions de cycles de manuvres

40

0.5

24

48

48

24

4
-2

0-

2
0
23

23

3
130

Action dpendante

Puissance coupe pour une durabilit de


5 millions de cycles de manuvres
12 -

12

Millions de cycles de manuvres

Action brusque

Durabilit lectrique en catgorie d'emploi DC-13

Action dpendante

0.1
1

10
Courant (A)

Tension

24 V

9.5 W

12 W

Tension

48 V

6.8 W

9W

Tension 110 V

3.6 W

6W

LS3..P80..-S and LS3..M80..-S Limit Switches


with Small Latch (Key) and adjustable Head
1 Cable Inlet for Cable Gland
Movement to be detected:

Small Latch (Key), Front or Vertical Translation

Casing 30 mm width

Plastic: Degree of protection IP65


Metal: Degree of protection IP66

Actuator
Conformity /
(N.C. contact with positive opening operation)
Actuation speed: maximal / minimal
Min. force / torque: - for insertion of the key
- for extraction of the key
- positive opening operation

Key

Key

0.5 / 0.01 m/s


15 N
15 N
30 N

0.5 / 0.01 m/s


15 N
15 N
30 N

Additional Technical Data (Operating diagrams with keys inserted)


LS type code to be complete with the cable inlet code ................................ 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT (by plastic adaptor for LS3..P80..-S)

Snap action contacts


slow action contacts

LS3

Type

21

13

0 3.8 5.3

Zb
22

14

5.0

0 3.8 5.3

21.5 mm

0 2.0 3.5

3.3

21.5 mm

21.5 mm

21-22
13-14

3.0

LS3
0

5.0

M80L02-S

21.5 mm

11-12
21-22

3.3

21.5 mm

11-12
21-22

3.5

1.8

kg

21.5 mm

4.8

11-12
21-22

3.5

M80D11-S

21-22
13-14

P80L02-S

11-12
21-22

Weight (packing per unit)

21.5 mm

3.0

LS3

Type

Operation
diagram

22

12

0 2.0 3.5

LS3

21-22
13-14

4.8

21

11

21.5 mm

21-22
13-14

Operation
diagram

Simultaneous
Slow action contacts

P80D11-S

1.8

0.080

0.180

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

R 400 mini.
90

92

4
4

20
55

22

30.3

30

cable inlet

22

L0360D2G

53

cable inlet

L0359D

L0377D

30

L0403D

20

L1260D1G

R 400 mini.
19.2

37

7
37

30

30

12

6.6

24.1

6.6

24.1
L0374D

L0373D

8x24

12.45

12.45

1.6

L1259D

11

23

4.4

30

30
22
9.4

30.3

32.5

51
1SBC141157C0202

LS4..P80..-S and LS4..M80..-S Limit Switches


with Small Latch (Key) and adjustable Head
1 Cable Inlet for Cable Gland
Movement to be detected:

Small Latch (Key), Front or Vertical Translation

Casing 40 mm width

Plastic: Degree of protection IP65


Metal: Degree of protection IP66

Actuator
Conformity /
(N.C. contact with positive opening operation)
Actuation speed: maximal / minimal
Min. force / torque: - for insertion of the key
- for extraction of the key
- positive opening operation

Key

Key

0.5 / 0.01 m/s


30 N
30 N
45 N

0.5 / 0.01 m/s


30 N
30 N
45 N

Additional Technical Data (Operating diagrams with keys inserted)


LS type code to be complete with the cable inlet code ................................ 0 = Pg 13.5
3 = M20 x 1.5
5 = 1/2" NPT

Non-overlapping
slow action contacts

LS4

Type

13 21 31

14 22 32

Simultaneous
Slow action contacts

13-14
23-24
31-32

5.3

11-12
21-22
31-32

4.3 5.8

26.6 mm

5.5 7

13-14
23-24
31-32

AP
AP

26.6 mm

11-12
21-22
31-32

26.6 mm

13-14
23-24
31-32

6.7

4.1

26.6 mm

5.3

11-12
21-22
31-32

4.3 5.8

26.6 mm

AP
AP

5.5

LS4

M80L03-S

26.6 mm

11-12
21-22
31-32

5.6

kg

M80D12-S

AP
AP

P80L03-S

6.8

Weight (packing per unit)

LS4

5.5

LS4

Type

Operation
diagram

22 32

26.6 mm

AP
AP

6.7

11 21 31

12

5.5 7

13-14
23-24
31-32

Operation
diagram

P80D12-S

4.1

26.6 mm

5.6

6.8

0.155

0.210

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)

10
5.3
30
70

cable inlet

cable inlet

67

41

L1263D

L1262D1G

L1261D

41.3

L1264D1G

5.3

5.5

L0403D
L0377D1

32.5

1SBC141157C0202

43

33
7.3
113

5.5
30

52

6.6

10
42.5
7.5
109.5

R 400 mini.

22.2

32.5

L0374D1

L0373D

R 400 mini.

41

10

12

16

30

15.5 6.6

30

1.6
2

8x24

28

4.4
11

30
22
9.4

40

43.3

LS3..P7..-S and LS3..M7..-S Limit Switches


with Rotative Axis and adjustable Head
1 Cable Inlet for Cable Gland
Movement to be detected:

Angular Around Rotative Axis

Casing 30 mm width

Plastic: Degree of protection IP65


Metal: Degree of protection IP66

90

Actuator

90

90

90

Rotative Axis (zinc plated)

Stainless Steel Rotative Axis

0.5 / 0.01 m/s


0.12 N.m
0.60 N.m

0.5 / 0.01 m/s


0.12 N.m
0.60 N.m

Conformity /
(N.C. contact with positive opening operation)
Actuation speed: maximal / minimal
Min. force / torque: - actuation
- positive opening operation

Additional Technical Data


LS type code to be complete with the cable inlet code

0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT (by plastic adaptor for LS3..P7..-S)

Non-overlapping
slow action contacts
13

21-22

Operation
diagram

22

Simultaneous
Slow action contacts
11

12

P75D11-S

21

Zb
14

LS3

Type

31 6 6 31

13-14

LS3

Type

21

15 0 15

P75L02-S
11-12

90

21-22

Operation
diagram

22

90

Weight (packing per unit)

kg

LS3

LS3

30 5 0 5 30
30 5 5 30

0.090

M75D11-S

LS3

P76D11-S

90 21-22

21-22

13-14

13-14

M75L02-S

LS3

90

LS3

31 6 6 31

11-12

21-22

21-22

0.190

0.090

90 21-22
13-14

15 0 15

P76L02-S

90 11-12

M76D11-S

90

LS3

30 5 0 5 30

M76L02-S
90 11-12
21-22

30 5 5 30

0.190

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)
Plastic Casing
(for Metal Casing see page 54)
51.4
27
13.2
7

30
22

24.1

3.2

24.5

20

8.4

27

18

3.2

L0407D

20

L0406D1

L0488D1G

53
L0487D

30.3

LS3P = 80, LS3M = 82

cable inlet

12

12.5

15

53
1SBC141157C0202

LS3..P7..-S and LS3..M7..-S Limit Switches with


Right Angle Lever and Adjustable Head
1 Cable Inlet for Cable Gland
Movement to be detected:

Angular with Lever

Casing 30 mm width

Plastic: Degree of protection IP65


Metal: Degree of protection IP66

Lever adjusted to the left


(by user)

Actuator

Lever in central position


(factory assembled)

Lever adjusted to the right


(by user)

Galvanized steel ush mounting right angle lever

Conformity /
(N.C. contact with positive opening operation)
Actuation speed: maximal/minimal
Min. force / torque: - actuation
- positive opening operation

0.5 / 0.01 m/s


0.12 N.m
0.60 N.m

Additional Technical Data


LS type code to be complete with the cable inlet code ......................................................... 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT (by plastic adaptor for LS..P7..-S)

Non-overlapping
slow action contacts
13

LS3

Type

21

0 6

Zb
14

22

Simultaneous
Slow action contacts
11

180

LS3
0 5 30

Weight (packing per unit)

90

13-14

Type
180

11-12
21-22

Operation
diagram

22

21-22

15

21

12

31

21-22
13-14

Operation
diagram

P77D11-S / LS3

P77L02-S / LS3
11-12

kg

90 21-22

90

30 5 0 5 30

180

31 6 0
21-22
13-14

13-14

15 0 15

21-22

5 30

31 6 6 31

M77D11-S

15

M77L02-S
90 11-12
180

21-22

30 5 5 30

30 5 0
11-12
21-22

LS3..P77..-S = 0.110 kg / LS3..M77..-S = 0.210 kg

Special heads, accessories and special contact arrangement or particular function: please consult us.

Closed contact /

Open contact

Dimensions (mm)
Metal Casing
(for Plastic Casing see page 53)
42

32.5

54
1SBC141157C0202

* Adjusted to maximum by factory

LS3P = 90.7 ... 9.5, LS3M = 92.7 ... 97 *

18
L0405D

14.5

L1292DG

30.3

L1009D

cable
inlet

L0404D1

55

20
22

LS3P = 80, LS3M = 82

5.3

48.7

LS3P = 153.2 ... 157.5, LS3M = 155.2 ... 159.5 *

12.5

O4

7.65

16

74.55 ... 78.85 *

39

LS3..P98..-SCR, LS3..M98..-SCR, LS4..M98..-SCR


and LS6..M98..-SCR Safety Limit Switches
With Pulling Cable for Emergency Stop and Manual Reset
Movement to be detected:

Stop by Pulling the cable

Casing 30 mm width

Plastic: Degree of protection IP65


Metal: Degree of protection IP66
1 cable inlet for cable gland

Casing 40 mm width
Metal: Degree of protection IP66
1 cable inlet for cable gland

Casing 60 mm width
Metal: Degree of protection IP66
3 cable inlets for cable gland

Actuator

Red cable

Red cable

70 N
95 N
120 N
115 N

100 N
170 N
250 N
240 N

Conformity /
(N.C. contact with positive opening operation)
Min. force : - for arming the safety system (F)
- for actuation
- for activating the reset and stop (F1)
- positive opening operation

Additional Technical Data


LS type code to be complete with the cable inlet code ................................ 0 = Pg 13.5
1 = Pg 11 (except for LS4..M98..-SCR and LS6..M98..-SCR)
2 = M16 x 1.5 (except for LS4..M98..-SCR and LS6..M98..-SCR)
3 = M20 x 1.5
5 = 1/2" NPT (by plastic adaptor for LS3..P98..-SCR)

Non-overlapping
slow action contacts

LS3

Type

P98D11-SCR
(0)
6.0

21

13

Zb
22

14

21-22
13-14

Operation
diagram

Simultaneous
slow action contacts

LS3

22

12

11-12
21-22

Operation
diagram

(30)
2.8

M98D11-SCR
(0)
6.0
21-22
13-14

M98L02-SCR

LS4

(0)
6.0

F1

LS4

Type

14 22 32

LS4

22 32

Closed contact /

kg

0.115

LS6

0.270

M98D12-SCR
(300) (N)
F1 4.0 mm

13-14
21-22
31-32

3.2
(40)

11-12
21-22
31-32

Weight (packing per unit)

F1

(100)
0

(0) (40)
6.0 2.8

Operation
diagram

11-12
21-22

M98L03-SCR

11 21 31

M98L02-SCR

(240) 250 (300) (N)


2.4 2.8 4.0 mm

13-14
21-22
31-32

Type

LS6

(0)
6.0

Simultaneous
slow action contacts

F1

(100)
0

M98D12-SCR

Operation
diagram

21-22
13-14

(40)
4.7

11-12
21-22

11-12
21-22

M98D11-SCR

(240)(260)(300) (N)
2.6 2.8 6.0 mm

M98L02-SCR

(115)(120)(140) (N)
2.4 2.8 4.0 mm

LS6
(100)
0
F

13 21 31

12

(40)
3.7

F1

LS3
(70)
0

LS4

21-22
13-14

P98L02-SCR
(0)
6.0

M98D11-SCR

(115)(120)(140) (N)
2.6 2.8 4.0 mm

Type

Non-overlapping
slow action contacts

LS3
(70)
0

21

11

(30)
3.7

2.7 3.2
(190) (250)

LS6
(100)
0

mm
(N)

M98L03-SCR

(240)(250)(300) (N)
2.4 2.8 4.0 mm
11-12
21-22
31-32

F1

0.270

0.300

Open contact

Dimensions (mm)
LS3..M98..-SCR

LS4..M98..-SCR

30.3

40.5

30.3

40.5

10

15

40

15

17

158.25

5.3

cable
inlet

40

44

L1394D

5.3

10

cable
inlet

15

7.3

30

82.5

5.3

15

10

17

7.3

162.75
87

70

22

30
L1392D

cable
inlet

15

10

15

145.75

15
L1391D

cable
inlet

15

4
6
22

20

30

24

24

10

143.75
68

20

16

16

24

24

LS6..M98..-SCR

12.5

12.5

L1393D

LS3..P98..-SCR

63

44

55
1SBC141157C0202

Limit Switches with Latch and Manual Reset


Plastic Casing IP65

and Metal Casing IP66 - 30 mm Width

Applications
Easy to use, the limit switches for safety applications with latch and manual reset offer specic qualities:

Visible operation (fault memorisation).


Capability for strong current switching (conventional thermal current 10 A).
Contact blocks with positive opening operation of the "N.C." normally closed contact(s) (symbol
Electrically separated contacts.
Precision on operating positions (consistency).
Immunity to electromagnetic disturbances.

).

These specic features make the limit switches ideal for detection and monitoring of faults in hoisting machines, electric lifts, freight
elevators, escalators, conveyor belts, etc.
Limit switches with latch and manual reset comply with the requirements of standard EN 81-1: safety rules for the construction and installations
of electric lifts. In this application they detect or monitor: cabin overtravel, cabin speed by means of a speed limiting device, energisation of the
parachute block on detection of excessive speed with respect to the set-point value, etc.
They comply with the requirements of European Directives (Low Voltage, Machines and Electromagnetic Compatibility) and are conform to European and international standards.

Description
LS3..P..-R (plastic casing, 30 mm width) limit switches with latch and manual reset, which are made of fibreglass reinforced UL-V0 thermoplastic
material, offer double insulation and a degree of protection IP65.
LS3..M..-R (metal casing, 30 mm width) limit switches, which are made of zinc alloy (zamack), have a degree of protection IP66.
Limit switches with latch and manual reset are equipped with 1 N.C. + 1 N.O. or 2 N.C. contact blocks with positive opening operation of the
"N.C." contact(s). After actuating the control device and overshooting the latching point, the N.C. safety contact(s) remain in the open position.
Return to the initial operating state takes place by voluntary action on the reset button.

Casing
30 mm wide with standardized dimensions corresponding
to EN 50047

A variety of operating head options:


Plain plunger
Roller plunger
Roller lever adjustable or not, etc.
Assembly using 4 x 3 screws for LS3..P..
Assembly using 4 x M3 screws for LS3..M..

Casing xing
2 x M4 screws in the top part
Block of 2 contacts
Contact configuration: 1 N.O. + 1 N.C. or 2 N.C.
Positive opening operation
Snap or dependent action
The 2 contacts are electrically separated

Blue manual reset button


Cover
Closed using 1 x 3 screw for LS3..P..-R
Closed using 3 x M3 screws for LS3..M..-R
One piece sealing gasket to ensure tightness

Connecting terminals
M3.5 (+,-) posidriv 2 screw
(Screw head with captive cable clamp)
Marking conform to IEC 60947-1, IEC 60947-5-1,
EN 50005 and EN 50013 standards

Type

Example :

L0499D

Terminal for protective conductor placed near the


cable inlet and marked:
(LS3..M only)
M3.5 (+,) pozidriv 2 screw
(Screw head with captive cable clamp)

L S

3 0

L S

P
P

Limit Switch .................................................................................LS

Casing width: 30 mm ..................................................................................... 3


1 cable inlet for Pg 13.5 cable gland ....................................................................0
1 cable inlet for Pg 11 cable gland .......................................................................1
1 cable inlet M16 x 1.5 for ISO 16 cable gland ....................................................2
1 cable inlet M20 x 1.5 for ISO 20 cable gland ....................................................3
1 cable inlet by 1/2" NPT plastic adaptor (LS35P) or 1/2" NPT for cable gland
(LS35M) ................................................................................................................5

Plastic casing..................................................................................................................... P
Metal casing ......................................................................................................................M

56
1SBC141157C0202

Electrical connection:
1 (LS30P/M) cable inlet for Pg 13.5 cable gland
1 (LS31P/M) cable inlet for Pg 11 cable gland
1 (LS32P/M) cable inlet for ISO 16 cable gland
1 (LS33P/M) cable inlet for ISO 20 cable gland
1 (LS35P) cable inlet by 1/2" plastic adaptor
1 (LS35M) cable inlet for 1/2" cable gland
Suitable for conduit connection only with use of adaptor
sleeve optionally provided by manufacturer (on request).

1 3

D 1 1

R
R
R ...........Reset Device

Contact types:
11 ........... 1 N.O. + 1 N.C. contacts
02 ........... 2 N.C. contacts

Snap action:
B ...........Zb Snap
Dependent (slow) action:
L ............Slow / Simultaneous
D ...........Zb Non-overlapping late make
C ...........Zb Overlapping early make

Operating heads: (see panorama)


11 ... 55 and 71 ... 74, 78 .............................................................................................codes

LS3..P..-R and LS3..M..-R Limit Switches


with Latch and Manual Reset
Plastic Casing IP65

and Metal Casing IP66 - 30 mm Width

SB8125CM

LS30P: 1 cable inlet for Pg 13.5 cable gland .......


LS31P: 1 cable inlet for Pg 11 cable gland ..........
LS32P: 1 cable inlet for ISO 16 cable gland .........
LS33P: 1 cable inlet for ISO 20 cable gland .........
LS35P: 1 cable inlet by 1/2" NPT plastic adaptor ..

LS31P11D11-R

0 ............................................. 0 2
1 ............................................. 0 1
2 ............................................. 0 3

Plastic Casing - 30 mm Width


IP65

3 ............................................. 2 2
5 ............................................. 2 1

LS30M: 1 cable inlet for Pg 13.5 cable gland ...... 0


LS31M: 1 cable inlet for Pg 11 cable gland ......... 1
LS32M: 1 cable inlet for ISO 16 cable gland ........ 2
LS33M: 1 cable inlet for ISO 20 cable gland ........ 3
LS35M: 1 cable inlet by 1/2" NPT plastic adaptor .. 5

.............................................
.............................................
.............................................
.............................................
.............................................

1 8
1 7

Metal Casing - 30 mm Width


IP66

1 9
3 8
3 7

Ordering Details
Contact blocks
13

21

14

22

11

21

12

22

Type

Order code

Weight
kg (1)

state cable inlet code

state cable inlet code

Packing
1 piece

Zb
D11

B02

SB8120CM

Plastic Limit Switches with steel plain plunger (zinc plated)

LS31P13D11-R

LS3

P11D11-R

1SBV02

11R1411

0.090

LS3

P11B02-R

1SBV02

11R1202

0.090

Plastic Limit Switches with plastic (polyacetal) roller plunger


1

LS3

P13D11-R

1SBV02

13R1411

0.090

LS3

P13B02-R

1SBV02

13R1202

0.090

1SBC5 9227 2F030M

Plastic Limit Switches with plastic roller (polyacetal) lever

LS32M31D11-R

LS3

P41D11-R

1SBV02

41R1411

0.095

LS3

P41B02-R

1SBV02

41R1202

0.095

Metal Limit Switches with steel plain plunger (zinc plated)


1

LS3

M11D11-R

1SBV02

11R1411

0.190

LS3

M11B02-R

1SBV02

11R1202

0.190

Metal Limit Switches with plastic (polyacetal) roller lever on steel plunger (zinc plated)
1

LS3

M31D11-R

1SBV02

31R1411

0.195

LS3

M31B02-R

1SBV02

31R1202

0.195

1SBC5 9229 2F030M

Metal Limit Switches with plastic roller (polyactal) lever


1

LS3

M41D11-R

1SBV02

41R1411

0.195

LS3

M41B02-R

1SBV02

41R1202

0.195

(1) For LS 35P add 0.007 kg

LS32M41D11-R

57
1SBC141157C0202

Limit Switches with Latch and Manual Reset


Travel and Operation diagrams

PO

C4
PP

CL

L
L0465D

SA

C2

PA

PR

C3

CA

C1

CP

F1

L0509D

C: travel in millimetres

C: travel in degrees

PO Free position:
position of the switch actuator when no external
force is exerted on it.

C1 Pre-travel (average travel):


distance between the free position PO and the
operating position PA.

PA Operating position:
position of the switch actuator, under the effect
of force F1, when the contacts leave their initial
free position.

CP Positive opening travel:


minimum travel of the switch actuator, from the free
position, to ensure positive opening operation of
the normally closed contact (N.C.).

PP Positive opening position:


position of the switch actuator from which positive
opening is ensured.

CA Latching travel (average travel):


distance between the free position PO and the
latching point SA.

SA Latching point:
point of no return of the switch actuator beyond
which the opened status of the (N.C.) contact(s)
is maintained. Unlocking will only occur after
deliberate action on the reset button.

C2 Over-travel (average travel):


distance between the operating position PA and
the max. travel position L.

Diagram for snap


action contacts:
CL
CP
C1
11-12
21-22
11-12
21-22

Actuation
Release
C4

L Max. travel position:


maximum acceptable travel position of the switch
actuator under the effect of a force F1.
PR Release position:
position of the switch actuator when the contacts
return to their initial free position.

CL Max. travel (maximum travel):


distance between the free position PO and the max.
travel position L.
C3 Differential travel (C1-C4) (average travel):
travel difference of the switch actuator between the
operating position PA and the release position PR.
C4 Release travel (average travel):
distance between the release position PR and the
free position PO.

Diagram for non-overlapping


slow action contacts:
CL
CP

21-22
13-14

and

C1-2
CA

5.4

21-22

Contact closed

21-22

Contact open

Contacts identification (example)

9.6 mm

21-22
13-14

4.3

LS30P41L02-R
simultaneous slow action contacts

7.5

Diagram in degrees / lever rotation


0 16

42

73

11-12
21-22

16

LS30P11B02-R
snap action contacts

42

54

Diagram in millimetres / plunger travel


0

2.4

4.0

5.9 mm

11-12
21-22
11-12
21-22

1.4

58
1SBC141157C0202

4.4

Actuation
Release

SA

Contacts position

Diagram in millimetres / cam travel


2.7

PP

C1-1

Examples:

SA

C3
CA

Note: for slow action contacts, C3 = 0, C1-1 = pre-travel of contact 21-22, C1-2 = pre-travel of contact 13-14.

LS30P13D11-R
non-overlapping slow action contacts

PP

Limit Switches with Latch and Manual Reset


Technical Data
General Technical Data
Plastic Casing

Metal Casing

Standards

IEC 60947-1, IEC 60947-5-1, EN 60947-1, EN 60947-5-1, UL 508, CSA C22-2 No.14

Certications - Approvals

UL - CSA - CCC

Air temperature near the device


during operation
for storage

C
C

-25 ... +70


-30 ... +80

Climatic withstand

According to IEC 68-2-3 and salty mist according to IEC 68-2-11

Mounting positions

All positions are authorised

Shock withstand (according to IEC 68-2-27 and EN 60068-2-27)

50 g (1/2 sinusoidal shock for 11 ms) no change in contact position

Resistance to vibrations (acc. to IEC 68-2-6 and EN 60068-2-6)

25 g (10 ... 500 Hz) no change in position of contacts > 100 s

Protection against electrical shocks (acc. to IEC 536)

Class II

Class I

Degree of protection (according to IEC 529 and EN 60529)

IP65

IP66

Consistency

0.1 mm upon closing points

Electrical Data
Rated insulation voltage Ui
according to IEC 60947-1 and EN 60947-1
according to UL 508, CSA C22-2 No.14

V
V

Rated impulse withstand voltage Uimp

500 (degree of pollution 3)


600

kV

10

10

A
A
A
A
A

10
5.5
3.1
3
1.8

A
A
A

2.8
0.6
0.27

400 (degree of pollution 3)


300

(according to IEC 60947-1 and EN 60947-1)

Conventional enclosed thermal current Ithe


(according to IEC 60947-5-1 and EN 60947-5-1) ( < 40 C)

Short-circuit protection gG type fuses


Rated operational current
Ie / AC-15 acc. to IEC 60947-5-1

24 V - 50/60 Hz
130 V - 50/60 Hz
230 V - 50/60 Hz
240 V - 50/60 Hz
400 V - 50/60 Hz

according to UL 508, CSA C22 No.14


Ie / DC-13

according to IEC 60947-5-1

24 V - d.c.
110 V - d.c.
250 V - d.c.

A 600

according to UL 508, CSA C22 No.14

Q 600

Positivity
m

Mechanical durability

25

Millions of operations

Max. switching frequency

> 1 million

Cycles/h

600

Electrical durability (according to IEC 60947-5-1 appendix C)


Max. switching frequency
Cycles/h
Load factor
Connecting data of contact blocks
Connecting terminals
Connecting capacity
1 or 2 x mm2 / AWG
Terminal marking

Utilization categories AC-15 and DC-13 (see curves and values below)
3600
0.5
M3.5 (+,) pozidriv 2 screw with cable clamp
0.5 mm2 / AWG 20 to 2.5 mm2 / AWG 14
According to EN 50013

Electrical durability for AC-15 utilization category

0.5
0.3

0.1
0.2 0.3

L0351DG

0.2

0.5

3
5
10
Current (A)

Voltage

24 V

9.5 W

12 W

Voltage

48 V

6.8 W

9W

Voltage 110 V

3.6 W

6W

0.5
0.3
0.2
L0350DG

Millions of operating cycles

13

23

40

48

-2

24

Slow action

Power breaking for a durability of


5 million operating cycles

24

48

Snap action

12 -

130

23

Electrical durability for DC-13 utilization category

Slow action

12

Millions of operating cycles

Snap action

0-

Q 300

Contacts with positive opening operation as per IEC 60947-5-1 chapter 3 and EN 60947-5-1

Resistance between contacts

A 300

0.1
1

10
Current (A)

59
1SBC141157C0202

LS3..P..-R Limit Switches


with Latch and Manual Reset
1 Cable Inlet for Cable Gland
Movement to be detected:

On end

30 Cam Translation

30 Cam Translation

Casing

Plastic
30 mm width
Degree of protection IP65

Actuator

Steel plain plunger

11 Plastic roller plunger

18 Rotary lever
with plastic roller

0.5 m/s
9N
44 N

0.3 m/s
12 N
41 N

1.5 m/s
0.10 N.m
0.32 N.m

Conformity /
(N.C. contact with positive opening operation)
Maximum actuation speed
Min. force / torque: - actuation
- positive opening operation

Additional Technical Data


LS type code to be complete with the cable inlet code ................. 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT (by plastic adaptor)

Non-overlapping
slow action contacts
13

Zb
14

22

12

P11D11-R
1.6

5.4

LS3

9.6 mm

2.4

4.0

LS3

kg

43
31

4.2 6.9

LS3

9.6 mm

73

0.090

29

53

73

11-12
21-22
11-12
21-22

2.4

4.4

54

P41B02-R

11-12
21-22
11-12
21-22

1.4

17

7.5

P13B02-R

5.9 mm

P41D11-R

21-22
13-14

4.3

P11B02-R

Weight (packing per unit)

2.7

4.4

11-12
21-22
11-12
21-22

Operation
diagram

P13D11-R

21-22
13-14

LS3

21

Closed contact /

5.9 mm

2.5

Type

22

3.2

LS3

21-22
13-14

Operation
diagram

Snap action
contacts
11

LS3

Type

21

7.5

14

0.090

54

0.95

Open contact

Dimensions (mm)
45
40
36.5
24.1

24.5

20

12.5

11

36.5

18

12.5
26.5

12.5
15

12.5

15

88

99

17

17

35

15

46

4
4

5.5

3.5

14

22

24.1

17.5

30

15

30.3

60
1SBC141157C0202

15

L0417D

L0416D

L0472D

L0471D

L0409D

L0408D

L0488D3

L0487D

53

cable inlet

36

LS3..M..-R Limit Switches


with Latch and Manual Reset
1 Cable Inlet for Cable Gland
Movement to be detected:

On end

30 Unidirectional Cam

30 Cam Translation

Casing

Metal
30 mm width
Degree of protection IP66

Actuator

Steel plain plunger

12.5 Plastic roller plunger


on galvanized steel plunger

18 Rotary lever
with plastic roller

0.5 m/s
9N
44 N

1 m/s
7N
24 N

1.5 m/s
0.10 N.m
0.32 N.m

Conformity /
(N.C. contact with positive opening operation)
Maximum actuation speed
Min. force / torque: - actuation
- positive opening operation

Additional Technical Data


LS type code to be complete with the cable inlet code ................. 0 = Pg 13.5
1 = Pg 11
2 = M16 x 1.5
3 = M20 x 1.5
5 = 1/2" NPT

Non-overlapping
slow action contacts
13

21

Zb
14

LS3

Type

Simultaneous
slow action contacts
11

21

12

22

3.2

5.9 mm

LS3

Type

5.3 10.7

LS3

19.6 mm

2.4

4.0

8.6

LS3

1.4

kg

LS3

8.4 13.8 19.6 mm

73

54

M41B02-R
29

53

73

11-12
21-22
11-12
21-22

4.6

4.4

0.190

43
31

11-12
21-22
11-12
21-22

11-12
21-22
11-12
21-22

17

15.6

M31B02-R

5.9 mm

M41D11-R

21-22
13-14

4.4

M11B02-R

Weight (packing per unit)

M31D11-R

21-22
13-14

2.5

Operation
diagram

Closed contact /

1.6

LS3

21-22
13-14

Operation
diagram

22

M11D11-R

15.6

14

0.195

54

0.195

Open contact

Dimensions (mm)
45
36.5

40

12.5
12.5
24.1

15
5.2

12.5

12.5

12.5

14

88

22

15

17.5

15

34.5

107

20

17

17

35

15

26.5

O4

32.5

L1270D

L1269D

L1268D

L1267D

14.5

L1266D

30.3

L1201D1

cable inlet
L1009D

55

5.5

18

36.5

36

61
1SBC141157C0202

Foot Switches
IPS Foot Switches with Covers, IPM Mini Foot Switches
Description
Application
Foot switch operated machines such as: shearing machines, folding machines, spinning lathes, machine tools, wrapping machines, riveting
presses, etc.
Foot switches with covers come in three operation formats:
Free movement: contact position follows pedal movement: actuated when the pedal is pushed down, released when pedal is in a state of rest.
Foot switch locked in neutral position: same operation as above, after unlocking the pedal with the end of the foot.
Foot switch latched in low position: same operation as free movement, except that a state of rest is obtained only after having unlatched
the pedal with the end of the foot.

Description of IPS Foot Switches with Covers

Dimensions: 285 x 140 x 145.


Materials: base, cover and pedal made of shock resistant Bayblend FR 90 material (alloyed polycarbonate and ABS).
Colour choice: grey base; grey, yellow or red cover.
Variations: grey base, half-red cover. Especially used for emergency stop function.

Note: this emergency stop function must never contain the locked in neutral position device.
Connecting terminals
M 3.5 (+, ) Pozidriv 2 screw
(Screw head with captive cable clamp)
Markings conform with IEC 60947-1,
IEC 60947-5-1, EN 50005 and 50013 standards.

4 stainless steel 18/8. Philips no. 2


screws

Cover

Cable inlet with


Pg 16 cable gland.

Cable clamp

Block(s) of two contacts:


one block: 1 N.O. + 1 N.C.
two blocks: 2 N.O. + 2 N.C.
Positive opening operation.
Zb snap action contacts or
Zb slow action contacts:
the contacts are electrically separated.

Pedal

1 pre-pressed Pg16
knockout on each side.

L0354D

Base

4 skidproof pads

On request: Foot switches with covers can be assembled on a plate and equipped with a transportation handle. Instead of the handle an
emergency stop button can be installed above a tube that allows for connection cable passage. (see the catalogue of separate elements)

Description of IPM Mini Foot Switches

Reduced dimensions: 100 x 75 x 34 mm.


Materials: cover and base made of self-extinguishing ABS.
Colour choice: black or grey base; black, grey, yellow or red cover.

Connections
M3 x 0.5 screw with Philips head no. 1 and washer

Cable guide

NO/NC contact block

Cover

L0353D

Cable clamp

Contact block
actuating lever

4 skidproof pads

Base

62
1SBC141157C0202

Pedal return spring

Foot Switches
IPS Foot Switches with Covers
IPM Mini Foot Switches
IPSY: Yellow Cover .............................................. Y ........................................................ 5
IPSG: Grey Cover ................................................ G ........................................................ 6
IPSR: Red Cover .................................................... R ........................................................ 8

Ordering Details
Contact blocks
Snap action
Non-overlaping
Slow action
21

13

13

21

14

22

Order code

Weight
kg (1)

state colour code

state colour code

Packing
1 piece

Zb

Zb
22

14

Type

B11

D11

1SB7812C4

Free Movement
1

IPS

1B11

1SBV 002 10

R1211

1.100

IPS

1D11

1SBV 002 10

R1411

1.100

Locked in Neutral Position

IPSY 1B11

IPS

2B11

1SBV 002 20

R1211

1.100

IPS

2D11

1SBV 002 20

R1411

1.100

Latched in Low Position


1

IPS

3B11

1SBV 002 30

R1211

1.100

IPS

3D11

1SBV 002 30

R1411

1.100

Ordering Details
Contact blocks
NC

Cover colour

Type

Order code

Weight
kg (1)

NO

Packing
1 piece

1SB7816C3

N.O. / N.C.

IPM1Y

Black Base
1

Yellow

IPM1Y

1SBV 001 101 R1823

0.130

Grey

IPM1G

1SBV 001 102 R1823

0.130

Yellow

IPM2Y

1SBV 001 105 R1823

0.130

Grey

IPM2G

1SBV 001 106 R1823

0.130

Grey Base

Dimensions (mm)
Foot Switches with cover

Mini Foot Switches

280

140

75

19.5

L0349D

4b

35

L0259D

51.5
35

L0260D

2.2a
L0261D

127

85

17.5b

138

12a

15.5

Plain foot switch - a = pre-travel, b = total travel

63
1SBC141157C0202

Foot Switches
Technical Data
General Technical Data
Mini Foot Switch

Foot Switch with cover

Standards

IEC 1058-1

Certications - Approvals
Air temperature near the device
during operation
C
for storage
C
Climatic withstand
Shock withstand (according to IEC 68-2-27 and EN 60068-2-27)
g
Resistance to vibrations (acc. to IEC 68-2-6 and EN 60068-2-6) g
Protection against electrical shocks (acc. to IEC 536)
Degree of protection (according to IEC 529 et EN 60529)
Operating angle
Degree
Actuation torque
N.m.

IEC 60947-1, IEC 60947-5-1, EN 60947-1, EN 60947-5-1, UL 508,


CSA C22-2 No.14
UL - CSA - BG - CCC

-10 ... +70


-25 ... +80

Class II
IP40
2 to 4
1.2

-10 ... +70


-30 ... +80
According to IEC 68-2-3 and salty mist according to IEC 68-2-11
50 g (1/2 sinusoidal shock for 11 ms) no change in contact position
25 g (10 ... 500 Hz) no change in position of contacts > 100 s
Class II
IP65
15
0.25

Rated insulation voltage Ui


V
according to IEC 60947-1 and EN 60947-1
V
according to UL 508, CSA C22-2 No.14
V
Rated impulse withstand voltage Uimp
kV
Conventional free air thermal current Ith
A
Short-circuit protection gG type fuses
A
Rated operational current
250 V - a.c. A
230 V - d.c. A
24 V - 50/60 Hz A
Ie / AC-15 acc. to IEC 60947-5-1
130 V - 50/60 Hz A
230 V - 50/60 Hz A
240 V - 50/60 Hz A
400 V - 50/60 Hz A
according to UL 508, CSA C22 No.14
Ie / DC-13 according to IEC 60947-5-1 24 V - d.c. A
110 V - d.c. A
250 V - d.c. A
according to UL 508, CSA C22 No.14
Positivity

250

1
15
10
3
0.06

Resistance between contacts


Mechanical durability
Max. switching frequency

30
10

100000

500 (degree of pollution 3)


600
6 (according to IEC 60947-1 and EN 60947-1)
10 (according to IEC 60947-5-1 and EN 60947-5-1) ( < 40 C)
10

10
5.5
3.1
3
1.8
A 600
2.8
0.6
0.27
Q 600
Contacts with positive opening operation as per IEC 60947-5-1
chapter 3 and EN 60947-5-1
25
30
600

Electrical Data

m
Millions of operations
Cycles/h
Operations

Electrical durability

Max. switching frequency


Cycles/h
Load factor
Connecting data of contact blocks
Connecting terminals
Connecting capacity
1 or 2 x mm2 / AWG
Terminal marking

Utilization categories AC-15 and DC-13 (see curves and values below)
3600
0.5

M3 x 0.5 screw with Philips head M3.5 (+,) pozidriv 2 screw with cable clamp

0.5 mm2 / AWG 20 to 2.5 mm2 / AWG 14


refer to contact block
According to EN 50013

Electrical durability for AC-15 utilization category

0.3

0.1
0.2 0.3

L0351DG

0.2

0.5

64
1SBC141157C0202

3
5
10
Current (A)

0.5
0.3
0.2
L0350DG

Millions of operating cycles

24

13

48

0.5

48

24

0.1
1

10
Current (A)

Slow action

Power breaking for a durability of


5 million operating cycles

23

0-

40

-2

130

Snap action
12 -

23

Electrical durability for DC-13 utilization category

Slow action

12

Millions of operating cycles

Snap action

(according to IEC 60947-5-1 appendice C)

Voltage

24 V

9.5 W

12 W

Voltage

48 V

6.8 W

9W

Voltage 110 V

3.6 W

6W

ABB France
Automation Products Division
Export Department
10, rue Ampre Z.I. - B.P. 114
F-69685 Chassieu cedex / France
Tel. : +33 (0) 4 7222 1722
Fax : +33 (0) 4 7222 1935
http://www.abb.com/lowvoltage

1SBC 141 157 C0203


Printed in France (pdf 04.2008)

As part of its on-going product improvement, ABB


reserves the right to modify the characteristics or the
products described in this document.
The information given is not-contractual. For further
details please contact the ABB company marketing these
products in your country.

Você também pode gostar